GlycolInjection This spreadsheet calculates the minimum amount of required inhibitor usage. Input Data: Gas flow rate: 10 MMscfd Gas specific gravity (g g ): 0.7 air = 1 Minimum pressure (p m ): 900 psia Inlet gas temperature (t i ): 90 o F Hydrate temperature p m : 64 o F Operating temperature (t o ): 40 o F Water content at t i and p m : 48 lb/MMscf Water content at t o and p m : 9.6 lb/MMscf Inhibitor data: Used (1=Yes; 0=No)? W in W out Density: EG 1 75% 65% 9.08 ppg DEG 0 75% 65% 9.08 ppg Concentration of inhibitor in its commercial solution: 75 Wt % Intermediate Calculations: Water to be removed from gas (w G ): 38.4 lb/MMscf Molecular weight of inhibitor (MW) inh : 62 Density of inhibitor (r inh ): 9.08 ppg Hammerschmidt constant for inhibitor (K H ): 4000 Depression of hydrate formation temperature (Dt h ): 24 o F W out for the selected inhibitor: 65 Wt % W in for the selected inhibitor: 75 Wt % Inhibitor requirement based on Hammerschmidt's method: = 27.11 Wt % -1 Inlet concentration to be used: 75 Wt % 1 = 187.20 lb/MMscf Result: Required volume of commercial inhibitor solution: 249.6 lb/MMscf Required weight of commercial inhibitor solution: 27.49 gal/MMscf Hourly inhibitor injection rate: 11.45 gal/hour Daily inhibitor injection rate: 274.89 gal/day Instructions: 1) Update input data in blue; 2) View result. 100 ) ( ) ( D D H h inh h inh h K t MW t MW W in out G W W W I 100 100 100

Upload: math62210

Post on 08-Apr-2016

20 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Glycol Injection

GlycolInjectionThis spreadsheet calculates the minimum amount of required inhibitor usage.

Input Data:

Gas flow rate: 10 MMscfdGas specific gravity (gg): 0.7 air = 1

Minimum pressure (pm): 900 psia

Inlet gas temperature (ti): 90 oF

Hydrate temperature pm: 64 oF

Operating temperature (to): 40 oF

Water content at ti and pm: 48 lb/MMscf

Water content at to and pm: 9.6 lb/MMscf

Inhibitor data: Used (1=Yes; 0=No)? W in Wout Density:

EG 1 75% 65% 9.08 ppg

DEG 0 75% 65% 9.08 ppg

Concentration of inhibitor in its commercial solution: 75 Wt %

Intermediate Calculations:

Water to be removed from gas (wG): 38.4 lb/MMscf

Molecular weight of inhibitor (MW)inh: 62

Density of inhibitor (rinh): 9.08 ppg

Hammerschmidt constant for inhibitor (KH): 4000

Depression of hydrate formation temperature (Dth): 24 oF

Wout for the selected inhibitor: 65 Wt %

W in for the selected inhibitor: 75 Wt %

Inhibitor requirement based on Hammerschmidt's method:

= 27.11 Wt % -1

Inlet concentration to be used: 75 Wt % 1

= 187.20 lb/MMscf

Result:

Required volume of commercial inhibitor solution: 249.6 lb/MMscf

Required weight of commercial inhibitor solution: 27.49 gal/MMscf

Hourly inhibitor injection rate: 11.45 gal/hour

Daily inhibitor injection rate: 274.89 gal/day

Instructions: 1) Update input data in blue; 2) View result.

100)(

)(

D

D

Hhinh

hinh

hKtMW

tMWW

inout

G

WW

WI

100100100