gm10 – main unit and modules firmware...

16
Copyright © 2014 Yokogawa Electric Corporation All Right Reserved - 1 - GM10 – Main Unit and Modules Firmware Update

Upload: others

Post on 13-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 1 -

GM10 – Main Unit and Modules Firmware Update

Page 2: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 2 -

Summary of Steps to update GM-10 firmware.

1) Update firmware of the main unit. 2) Establish communication (between PC and the GM). 3) Update firmware of the modules.

Page 3: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 3 -

(1) GM-10 Firmware Update.

Preparation ● Copy all the required files /folder to the root directory of the SD card. This

should consist of a folder named SYSTEM and (3) files, ndacSV_2_main.rom, ndacSV_boot.rom, and ndacSV_main.rom.

Insert the SD card ● Power on the GM while pressing START key. ● Once the procedure is completed, there will be disparity between firmware

of the main unit and the firmware of the modules and this will cause error. ● The following error message will be shown alternately in the GM. E5 , 59

This indicates completion of the procedure to update the main GM10 unit.

Page 4: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 4 -

(2) Re-Establish communication with the GM-10.

Install IP address configuration software to PC.

Connect the PC and GM using LAN cable. Launch the IP address configuration software. Find GM in the network.

Assign appropriate IP address to the GM.

Page 5: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 5 -

(3) Update firmware of the I/O modules.

Preparation ● Make sure that PC is communicating with the GM. ● Make sure the SD card (with update files) is inserted in the GM. Example (ex_r10201.iom or io_r10401.iom) ● Make sure that all the module configuration of the GM is correct.

(e.g. location of ex-communication module, dip switch setting of the ex-communication module)

● Power ON all the GM and its sub units.

Page 6: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 6 -

(3) Update firmware of the I/O modules.

Update procedure ● Launch web browser ● Type in IP address (e.g. http://192.168.1.1/ ) ● Select ‘Calib’ Tab and choose Update

Page 7: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 7 -

(3) Update firmware of the I/O modules.

● Press Next button (lower right of the window) and confirm with OK

Page 8: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 8 -

(3) Update firmware of the I/O modules.

● Mode Switching in progress message is displayed.

Page 9: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 9 -

(3) Update firmware of the I/O modules.

● Select ‘Module’ from Update Mode.

Page 10: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 10 -

(3) Update firmware of the I/O modules.

● Select NEXT in the bottom right corner and then Update.

Page 11: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 11 -

(3) Update firmware of the I/O modules.

● Updating (All modules) message will be displayed.

● When completed the Update Completed message will display.

Page 12: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 12 -

(3) Update firmware of the I/O modules.

● After completion , select END and apply reconfiguration (from ‘Calib’ tab)

● Select Exit current mode and OK.

● Repeat above procedure if Sub unit is used.

Page 13: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 13 -

(3) Update firmware of the I/O modules.

● Select Reconfiguration and all modules should display BLUE.

Page 14: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 14 -

Outdated firmware module – RED for status

Page 15: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 15 -

Module after firmware update – BLUE status

Page 16: GM10 – Main Unit and Modules Firmware Updateweb-material3.yokogawa.com/GM10_Firmware_Update.pdf · Title: Communication with SSL Detail Author: CIPD ISPC Created Date: 5/14/2015

Copyright © 2014 Yokogawa Electric Corporation All Right Reserved

- 16 -

Now, that’s SMART.