gmvm97 / gcvm97 - hvacdirect · 2018. 6. 14. · tap adjust high-stage cfm low-stage cfm tap adjust...

12
SS-GMVM97 www.goodmanmfg.com 10/17 Supersedes 2/17 * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifeme Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Online registraon is not required in California or Québec. Standard Features Cabinet Features ComfortNet™ Communicang System compable Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Self-calibrang modulang gas valve auto-configure for each installaon • Durable Silicon Nitride igniter Quiet variable-speed induced draſt blower Ulizes ComfortNet™ communicang, two-stage or single-stage thermostats Self-diagnosc control board with constant memory fault code history output to a dual 7-segment display • Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Efficient and quiet variable-speed airflow system gently ramps up or down according to heang or cooling demand Mulple connuous fan speed opons offer quiet air circulaon Auto-Comfort and enhanced dehumidificaon modes available All models comply with California 40 ng/J Low NOx emissions standard AHRI Cerfied; ETL Listed Designed for mul-posion installaon — GMVM97: upflow, horizontal leſt or right GCVM97: downflow, horizontal leſt or right Cerfied for direct vent (2-pipe) or non-direct vent (1-pipe) Easy-to-install top venng with oponal side venng Convenient leſt or right connecon for gas and electrical service • Cabinet air leakage (QLeak) ≤ 2% Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower secon Airght solid boom or side return with easy-cut tabs for effortless removal in boom air-inlet applicaons Contents Nomenclature........................................ 2 Product Specificaons ........................... 3 Dimensions ............................................ 4 Airflow Specificaons ............................ 6 Wiring Diagram.................................... 11 Accessories .......................................... 12 Modulating, Variable-Speed ECM Gas Furnace Up to 98% AFUE GMVM97 / GCVM97 Heating Input: 60,000–120,000 BTU/h

Upload: others

Post on 23-Jun-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

SS-GMVM97 www.goodmanmfg.com 10/17Supersedes 2/17

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

Standard Features Cabinet Features• ComfortNet™ Communicating System compatible• Heavy-duty aluminized-steel tubular heat exchanger • Stainless-steel secondary heat exchanger• Self-calibrating modulating gas valve

auto-configure for each installation • Durable Silicon Nitride igniter• Quiet variable-speed induced draft blower• Utilizes ComfortNet™ communicating,

two-stage or single-stage thermostats• Self-diagnostic control board with constant memory

fault code history output to a dual 7-segment display• Color-coded low-voltage terminals with provisions

for electronic air cleaner and humidifier• Efficient and quiet variable-speed airflow system gently

ramps up or down according to heating or cooling demand• Multiple continuous fan speed options offer quiet air circulation• Auto-Comfort and enhanced dehumidification modes available• All models comply with California 40 ng/J

Low NOx emissions standard • AHRI Certified; ETL Listed

• Designed for multi-position installation — GMVM97: upflow, horizontal left or right GCVM97: downflow, horizontal left or right

• Certified for direct vent (2-pipe) or non-direct vent (1-pipe)

• Easy-to-install top venting with optional side venting• Convenient left or right connection

for gas and electrical service• Cabinet air leakage (QLeak) ≤ 2% • Heavy-gauge steel cabinet with durable finish• Fully insulated heat exchanger and blower section• Airtight solid bottom or side return with

easy-cut tabs for effortless removal in bottom air-inlet applications

ContentsNomenclature ........................................ 2Product Specifications ........................... 3Dimensions ............................................ 4Airflow Specifications ............................ 6Wiring Diagram .................................... 11Accessories .......................................... 12

Modulating, Variable-Speed ECM Gas Furnace

Up to 98% AFUE

GMVM97 / GCVM97Heating Input: 60,000–120,000 BTU/h

Page 2: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

2 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 3

Nomenclature

G M V M 97 060 3 B N **

1 2 3 4 5,6 7,8,9 10 11 12 13,14

Brand Engineering

G - Goodman® Brand Major / Minor Revisions* Not used for inventory control.

Configuration NOx

M - Upflow/Horizontal N - Low NOx

C - Downflow/Horizontal

Cabinet Width

Motor B - 17½” C - 21"

V - Variable Speed ECM / ComfortNet D - 24½"

E - Multi-Speed ECM

S - Single Speed Maximum CFM

2 - 800 CFM 4 - 1600 CFM

Gas Valve 3 - 1200 CFM 5 - 2000 CFM

M - Modulating

C - Two- Stage MBTU/h

S - Single Stage 040 - 40,000 BTU/h

060 - 60,000 BTU/h

AFUE 120 - 120,000 BTU/h

97 - 97% AFUE 96 - 96% AFUE

92 - 92% AFUE

Page 3: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

2 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 3

Product Specifications

GMVM97 0603BNA

GMVM970803BNA

GMVM970804CNA

GMVM971005CNA

GMVM971205DNA

GCVM970603BNA

GCVM97 0803BNA

GCVM970804CNA

GCVM971005CNA

Heating Data

High Fire Input¹ 60,000 80,000 80,000 100,000 120,000 60,000 80,000 80,000 100,000

High Fire Output¹ 58,800 77,600 78,400 97,000 116,400 58,200 77,600 77,600 97,000

Low-Fire Steady-State Input¹ 30,000 40,000 40,000 50,000 60,000 30,000 40,000 40,000 50,000

Low-Fire Steady-State Output¹ 29,400 38,800 39,200 48,500 58,200 29,100 38,800 38,800 48,500

AFUE² 98 97 98 97 97 97 97 97 97

Temperature Rise Range (°F) 25 - 55 30 - 60 25 - 55 35 - 65 35 - 65 35 - 65 35 - 65 35 - 65 35 - 65

Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3"

No. of Burners 3 4 4 5 6 3 4 4 5

Circulator Blower

Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 1.5 - 4 2 - 5 2 - 5 1.5 - 3 1.5 - 3 1.5 - 4 2 - 5

Size (D x W) 11" x 8" 11" x 8" 11" x 10" 11" x 10" 11" x 11" 11" x 8" 11" x 8" 11" x 10" 11" x 10"

Horsepower @ 1075 RPM ½ ½ ¾ 1 1 ½ ½ ¾ 1

Speed VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM

Electrical Data

Min. Circuit Ampacity⁴ 8.8 8.8 11.6 15.4 15.4 8.8 8.8 11.6 15.4

Max. Overcurrent Device (amps)⁵ 15 15 15 20 20 15 15 15 20

Shipping Weight (lbs) 118 121 142 144 157 117 122 144 146

¹ Natural Gas BTU/h² DOE AFUE based upon Isolated Combustion System (ICS)³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon

furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC.

⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.• Gas Service Connection ½" FPT• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.• For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum

clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

Page 4: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

4 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 5

GMVM97 Dimensions

Minimum Clearances to Combustible Materials

Position Sides Rear Front Bottom Flue Top

Upflow 0" 0" 3" C 0" 1"

Horizontal 6" 0" 3" C 0" 6"

C = If placed on combustible floor, the floor MUST be wood ONLY.

Air Discharge

Air Return

Model W D H A B C D E

GMVM970603BNA 17½" 28⅞" 34½" 17½" 16" 13⅞" 12⅛" 13⅝"

GMVM970803BNA 17½" 28⅞" 34½" 17½" 16" 13⅞" 12⅛" 13⅝"

GMVM970804CNA 21" 28⅞" 34½" 21" 19½" 17⅞" 16" 17½"

GMVM971005CNA 21" 28⅞" 34½" 21" 19½" 17⅞" 16" 17½"

GMVM971205DNA 24½" 28⅞" 34½" 24½" 23" 20⅞" 19⅜" 20⅞"

59¼

19⅝

34½

¾

19½

¾

B

C

23

2⅜

1⅞

2

5

19⅝23

24⅞

31⅞

A

21⅛

2⅝

14

23

1⅜

¾

28¾

2⅜1⅞

2

2¾6½

1⅞

26½

23½Folded Flanges

22Unfolded Flanges

DUnfolded Flanges

EFolded Flanges

AirDischarge

AirDischarge

LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW

Condensate DrainTrap Exterior

Connection(Right or Left Side)

¾ PVC

Vent/ Flue Pipe2" PVC

Alternate Vent/ FlueLocation

Right-SideDrain Trap

Exterior Holes

High-VoltageElectrical Outlet

AlternateGas Supply

Low-VoltageElectrical Outlet

Standard Gas SupplyLocation

Center DimpleFor AlternateAir Intake Pipe3" OD Hole

Air Intake2" Pipe

Left-SideDrain Trap

Exterior Holes

High-VoltageElectrical Outlet

Low-voltageElectrical Outlet

Page 5: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

4 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 5

GCVM97 Dimensions

Air Return

Air Discharge

Model W D H A B C D E

GCVM970603BNA 17½" 28⅞" 34½" 17½" 14⅝" 14" 14½" 13⅝"

GCVM970803BNA 17½" 28⅞" 34½" 17½" 14⅝" 14" 14½" 13⅝"

GCVM970804CNA 21" 28⅞" 34½" 21" 18⅛" 17½" 18" 19½"

GCVM971005CNA 21" 28⅞" 34½" 21" 18⅛" 17½" 18" 19½"

Minimum Clearances to Combustible Materials

Position Sides Rear Front Bottom Flue Top

Downflow 0" 0" 3" NC 0" 1"

Horizontal 6" 0" 3" C 0" 6"

C = If placed on combustible floor, the floor MUST be wood ONLY.NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.

18¼

A

34½

4⅛

11⅜

14¾

25⅛

BReturn

28¾

C

6⅞ 6⅞

11⅜

14⅞

14¾

25⅛

3½ 2½

2

1⅞

2⅝

23

14

1⅜

1⅝

E

DUnfolded Flanges

18⅛Unfolded Flanges

20⅛Folded Flanges

2⅝

1⅞

2

3⅝

Front ViewRight-Side View

Top View

Low-VoltageElectrical Outlet

Alternate Gas

High-VoltageElectrical Outlet

Standard Drain TrapDrain Trap Holes

Air Intake Pipe2” PVC

Vent/Flue Pipe 2" PVC

Alternate Gas Supply

Alternate Vent/

High-Voltage Electrical Outlet

Right Side ExteriorDrain Trap Holes

Low-Voltage Electrical Outlet

AirDischarge

AirDischarge

Folded Flanges

B18¼

Page 6: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

6 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 7

GMVM97 Airflow Data

GMVM970603BNACooling Speed

(@ .1" - .8" w.c. ESP)

GMVM970603BNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 25 - 55°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 539 358

AMinus 10% 858 n/a

Normal 599 398 Normal 953 n/aPlus 10% 659 438 Plus 10% 1,048 51

BMinus 10% 735 501

BMinus 10% 953 n/a

Normal 817 557 Normal 1,059 51Plus 10% 899 613 Plus 10% 1,165 46

CMinus 10% 906 626

CMinus 10% 1,042 52

Normal 1,007 696 Normal 1,158 47Plus 10% 1,108 766 Plus 10% 1,274 42

DMinus 10% 1,091 729

DMinus 10% 1,134 48

Normal 1,212 810 Normal 1,260 43Plus 10% 1,333 891 Plus 10% 1,386 39

GMVM970803BNACooling Speed

(@ .1" - .8" w.c. ESP)

GMVM970803BNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 30 - 60°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 566 363

AMinus 10% 1,082 n/a

Normal 629 403 Normal 1,202 60Plus 10% 692 443 Plus 10% 1,322 54

BMinus 10% 725 486

BMinus 10% 1,184 n/a

Normal 806 540 Normal 1,316 55Plus 10% 887 594 Plus 10% 1,448 50

CMinus 10% 921 635

CMinus 10% 1,250 57

Normal 1,023 705 Normal 1,389 52Plus 10% 1,125 776 Plus 10% 1,528 47

DMinus 10% 1,107 737

DMinus 10% 1,256 57

Normal 1,230 819 Normal 1,396 51Plus 10% 1,353 901 Plus 10% 1,536 47

GMVM970804CNACooling Speed

(@ .1" - .8" w.c. ESP)

GMVM970804CNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 25 - 55°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 710 462

AMinus 10% 1,105 n/a

Normal 789 513 Normal 1,228 n/aPlus 10% 868 564 Plus 10% 1,351 53

BMinus 10% 870 594

BMinus 10% 1,203 n/a

Normal 967 660 Normal 1,337 54Plus 10% 1,064 726 Plus 10% 1,471 49

CMinus 10% 1,064 712

CMinus 10% 1,287 n/a

Normal 1,182 791 Normal 1,430 50Plus 10% 1,300 870 Plus 10% 1,573 46

DMinus 10% 1,238 822

DMinus 10% 1,364 53

Normal 1,375 913 Normal 1,516 47Plus 10% 1,513 1,004 Plus 10% 1,668 43

Notes:• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Do not operate above .5" w.c. ESP in heating mode.

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

Page 7: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

6 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 7

GMVM97 Airflow Data (cont.)

GMVM971005CNACooling Speed

(@ .1" - .8" w.c. ESP)

GMVM971005CNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 738 508

AMinus 10% 1,636 55

Normal 820 564 Normal 1,818 49Plus 10% 902 620 Plus 10% 2,000 45

BMinus 10% 1,020 706

BMinus 10% 1,683 53

Normal 1,133 784 Normal 1,870 48Plus 10% 1,246 862 Plus 10% 2,057 44

CMinus 10% 1,318 884

CMinus 10% 1,719 52

Normal 1,464 982 Normal 1,910 47Plus 10% 1,610 1,080 Plus 10% 2,101 43

DMinus 10% 1,562 1,133

DMinus 10% 1,761 51

Normal 1,736 1,259 Normal 1,957 46Plus 10% 1,910 1,385 Plus 10% 2,153 42

GMVM971205DNACooling Speed

(@ .1" - .8" w.c. ESP)

GMVM971205DNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 780 492

AMinus 10% 1,702 63

Normal 867 547 Normal 1,891 57Plus 10% 954 602 Plus 10% 2,080 52

BMinus 10% 1,044 748

BMinus 10% 1,746 62

Normal 1,160 831 Normal 1,940 56Plus 10% 1,276 914 Plus 10% 2,134 51

CMinus 10% 1,320 918

CMinus 10% 1,771 61

Normal 1,467 1,020 Normal 1,968 55Plus 10% 1,614 1,122 Plus 10% 2,165 50

DMinus 10% 1,719 1,150

DMinus 10% 1,825 59

Normal 1,910 1,278 Normal 2,028 53Plus 10% 2,101 1,406 Plus 10% 2,231 48

Notes• All furnaces ship as high speed for cooling. Installer must adjust blower

speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.

• Installation is to be adjusted to obtain temperature rise within the range specified oN THE RATING PLATE.

Minimum Filter Sizes

GMVM97 0603BNA

GMVM970803BNA

GMVM970804CNA

GMVM971005CNA

GMVM971205DNA

Filter Sizes (in²) (Qty) (1) 16 x 25 (side or bottom)(1) 20 x 25 (bottom) or (2) 16 x 25 (side)

Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.

Page 8: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

8 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 9

GCVM97 Airflow Data

GCVM970603BNACooling Speed

(@ .1" - .8" w.c. ESP)

GCVM970603BNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 590 390

AMinus 10% 844 64

Normal 656 433 Normal 938 57Plus 10% 722 476 Plus 10% 1,032 52

BMinus 10% 711 487

BMinus 10% 855 63

Normal 790 541 Normal 950 57Plus 10% 869 595 Plus 10% 1,045 52

CMinus 10% 875 617

CMinus 10% 887 61

Normal 972 686 Normal 986 55Plus 10% 1,069 755 Plus 10% 1,085 50

DMinus 10% 1,076 725

DMinus 10% 893 60

Normal 1,195 806 Normal 992 54Plus 10% 1,315 887 Plus 10% 1,091 49

GCVM970803BNACooling Speed

(@ .1" - .8" w.c. ESP)

GCVM970803BNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 562 365

AMinus 10% 950 n/a

Normal 624 405 Normal 1,056 n/aPlus 10% 686 446 Plus 10% 1,162 62

BMinus 10% 727 494

BMinus 10% 1,031 n/a

Normal 808 549 Normal 1,146 63Plus 10% 889 604 Plus 10% 1,261 57

CMinus 10% 895 610

CMinus 10% 1,130 64

Normal 994 678 Normal 1,256 57Plus 10% 1,093 746 Plus 10% 1,382 52

DMinus 10% 1,059 706

DMinus 10% 1,214 59

Normal 1,177 784 Normal 1,349 53Plus 10% 1,295 862 Plus 10% 1,484 48

Notes• All furnaces ship as high speed for cooling. Installer must adjust blower

speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.• Installation is to be adjusted to obtain temperature rise within the range specified on the rating plate.

Page 9: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

8 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 9

GCVM97 Airflow Data (cont.)

GCVM970804CNACooling Speed

(@ .1" - .8" w.c. ESP)

GCVM970804CNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 753 500

AMinus 10% 1,111 65

Normal 837 556 Normal 1,234 58Plus 10% 921 612 Plus 10% 1,357 53

BMinus 10% 920 643

BMinus 10% 1,193 60

Normal 1,022 714 Normal 1,325 54Plus 10% 1,124 785 Plus 10% 1,458 49

CMinus 10% 1,085 754

CMinus 10% 1,298 55

Normal 1,206 838 Normal 1,442 50Plus 10% 1,327 922 Plus 10% 1,586 45

DMinus 10% 1,328 892

DMinus 10% 1,375 52

Normal 1,475 991 Normal 1,528 47Plus 10% 1,623 1,090 Plus 10% 1,681 43

GCVM971005CNACooling Speed

(@ .1" - .8" w.c. ESP)

GCVM971005CNAHeating Speed

(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)

Tap Adjust High-StageCFM

Low-StageCFM Tap Adjust High-Stage

CFMRise(°F)

AMinus 10% 706 472

AMinus 10% 1,583 57

Normal 784 524 Normal 1,759 51Plus 10% 862 576 Plus 10% 1,935 46

BMinus 10% 970 670

BMinus 10% 1,617 56

Normal 1,078 744 Normal 1,797 50Plus 10% 1,186 818 Plus 10% 1,977 45

CMinus 10% 1,249 834

CMinus 10% 1,656 54

Normal 1,388 927 Normal 1,840 49Plus 10% 1,527 1,020 Plus 10% 2,024 44

DMinus 10% 1,589 1,067

DMinus 10% 1,693 53

Normal 1,766 1,185 Normal 1,881 48Plus 10% 1,943 1,304 Plus 10% 2,069 43

Notes• All furnaces ship as high speed for cooling. Installer must adjust blower

speed as needed.• For most jobs, about 400 CFM per ton when cooling is desirable.

• Installation is to be adjusted to obtain temperature rise within the range specIFIED ON THE RATING PLATE.

Minimum Filter Sizes

GCVM970603BNA

GCVM97 0803BNA

GCVM970804CNA

GCVM971005CNA

Filter Sizes (in²) (Qty) (2) 10 x 20 or (1) 16 x 25 (top return)(2) 14 x 20 or

(1) 20 x 25 (top return)

Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located.

Page 10: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

10 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 11

Temperature Rise Range Chart

3040

5060

7080

9011

012

010

013

014

015

0

100

90 80 70 60 50 40 30 20 10

OU

TPU

TB

TU/H

Rx

1000

BTU

OU

TPU

Tvs

TEM

PE

RAT

UR

ER

ISE

CH

AR

TTEMPERATURERISE

600

CFM

700

900 10

00 1100 12

00

1400

1600 18

00 2000 22

00 2400

CFM

FOR

MU

LAS

BTU

OU

TPU

T=

CFM

x1.

08x

RIS

E

RIS

E=

BTU

OU

TPU

T1.

08÷

CFM

800

Temperature Rise

Out

put

BTU

/h x

1,0

00

Form

ulas

BTU

/h O

utpu

t = C

FM x

1.0

8 x

Rise

Rise

=

BTU

/H O

utpu

t

CFM

x 1

.08

BTU

/h O

utpu

t Vs

. Tem

pera

ture

Ris

e Ch

art

Page 11: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

10 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com 11

Wiri

ng is

sub

ject

to c

hang

e. A

lway

s re

fer

to t

he w

iring

dia

gram

on

the

unit

for t

he m

ost u

p-to

-dat

e w

iring

.⚠

W

arning

High

Vol

tage

: D

isco

nnec

t al

l po

wer

bef

ore

serv

icin

g or

ins

talli

ng t

his

unit.

Mul

tiple

pow

er

sour

ces

may

be

pres

ent.

Fai

lure

to d

o so

may

cau

se p

rope

rty

dam

age,

per

sona

l inj

ury,

or d

eath

.⚡

Wiring Diagram

GR GREEN

RD REDGY GRAY

OR ORANGE

COLOR CODES:PK PINKBR BROWNWH WHITEBL BLUE

YL YELLOW

PU PURPLE

BK BLACK

VAC115

SENSORFLAME

INTEGRATED CONTROLMODULE

GY

BL

RA

MPIN

G

GY

40 VATR

ANSFO

RM

ER

BR

BK

OR

(10)

GND

2

OR

AUX

HSI9

8

12

1

11

7

2 54

3 6

10

DEH

UMW2C1 Y12 R

W1

EAC

HU

M

Y2

ID BLO

WER

CO

NN

ECTO

R

G OLED'S

DIAGNOSTIC4

FLAME

SENSO

R

1

DELAY

3

NEU

TRAL

13

2

DEH

UM

LINE

AD

JUST

FUSE

2

BIAS

OR

YL

BK

WH

WH

WH

WH

OR

RD

WH BK

BR

OR

RD

BKG

YBL

2

AUXILIARY

PK

WARNING:DISCONNECT

MICROTO

OR

N

NO

3

BR

L

1

PRESSURE

(2)

SENSORFLAME

GR

C

G

VAC

1

C

(ON SOME MODELS)

PU

VALVEGAS

RD

AND GROUNDED.

1

BLWR

NEUTRAL

115

WH

FIELD GND

WARNING:

W2

GROUNDED.

2

GR

BL

BR

TRANSFORMER

WH

NO

SWITCH

WH

(11)

1

NEUTRAL

OR

Y2

ELECTRONIC

Y1

WHAIR

L

PU

NOTES:

(3)

PK

IGN

3

BK

GND (4)

5

WH

O

NO

W1

SWITCHPRESSUREHIGH FIRE

PU

DISCONNECT

2

FS

C

NEUTRAL

4

BK

LINE

C

DOOR OPEN)

COMPARTMENTBLOWER

NEUTRAL

JUNCTION BOX

GND

1

R

BLOWERCIRCULATOR

BLWR

JUNCTION

OR

CONTROLS

1

N

HUMIDIFIER

INDOOR

HIGH FIRE

DISCONNECT

MODULATING

C

(6)

OVERCURRENT

HUM

CONNECTOR

YL

GND

VAC

CH

ASSISG

RO

UN

D

2

3

4

SWITCH

DOOR

NEUTRAL

(8)

IGNITERSURFACE

HOT

2

GND

DEHUM

YL

PU

INDUCTOR COIL

C

EAC

BLOWERDRAFT

INDUCED

PM

24

IGNITER

0140F02013-AOVERCURRENT

BK

CIRCULATOR

3

(12)NO

HARNESS

PM

TERMINAL

OR

IGNITER

RD

BK

C

TO

RD

LINE

PROTECTIONDEVICE

GND

BK BLGYRD

INDOORAIR

CIRCULATORBLWRTX (3)

RX (2)

+ VDC (1)

GND (4)R

TO

MICROTO

Ø /60HZ115 VAC/1POWER SUPPLY WITH

POWER BEFORE SERVICINGWIRING. TO UNIT MUST BE

TO UNIT MUST BE

PROPERLY POLARIZED

EQUIPMENT GND

FIELD SPLICE

SWITCH (TEMP)

SWITCH PRESSURE

PROT. DEVICE

LOW VOLTAGE FIELD

LOW VOLTAGE (24V)

HI VOLTAGE (115V)

HI VOLTAGE FIELD

INTERNAL TOINTEGRATED CONTROL

PLUG CONNECTION

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE

USED WHEN SERVICING.3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE

FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITHWIRING MATERIAL HAVING A TEMPERATURE RATING OF ATLEAST 105°C. USE COPPER CONDUCTORS ONLY.

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TON.E.C. AND LOCAL CODES.

5. TO RECALL THE LAST 10 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDSWHILE IN STANDBY (NO THERMOSTAT INPUTS)

ECM MTR

24 V 3A

DOOR SWITCH(OPEN WHEN

24V THER

MO

STAT C

ON

NEC

TION

S N.E.C

. CLASS 2 W

IRE

INTEG

RATED

CO

NTR

OL M

ODU

LE24V H

UM

.

24 V THERMOSTAT CONNECTIONSN.E.C. CLASS 2 WIRE

PU

LL DO

WN

PULL U

P

CO

OL SETU

PH

EAT SETUP

HEAT O

FF DIP SW

ITCH

ES

FAN TAPS

HE

AT TAPS

CO

OL TAPS

MO

DU

LATING

INTER

GR

ATEDFU

RN

ACE C

ON

TRO

L MO

DU

LE

LIMIT CONTROL

AUTO RESET

BLOWER COMPARTMENT

BURNER COMPARTMENT

AUTO RESET PRIMARYLIMIT CONTROL

MANUAL RESET ROLLOUT LIMIT CONTROLS(SINGLE CONTROL ON 40 kBTU)

2 CIRCUIT

GAS VALVE(HONEY WELL)

LOW FIRE

SWITCH

ID BLOWER MODULATING PRESSURESWITCH ASSEMBLY

TO 115VAC/1 Ø /60 HZ POWER SUPPLY WITHOVERCURRENT PROTECTION DEVICE

DISCONNECT POWERBEFORE SERVICINGWIRING TO UNITMUST BE PROPERLYPOLARIZED AND

AIR CLEANER

INTEG

RATED

CO

NTR

OL M

OD

ULE

3Ø ID

HOT SURFACE

40 VAFUSE 3A TR (5)

TO+VDC

24 VACAUTO RESET AUXILIARY LIMIT

AUTO RESET PRIMARYLIMIT CONTROL

LOW FIREPRESS.

PRESS. SWITCH MANUAL RESET ROLLOUTLIMIT CONTROLS

TR (9)

OPTIONAL

OPTIONAL

INDUCTOR COIL

(ON SOME MODELS)

CGYGY

NOFRONT COVER

PRESSURE SWITCH

C

(7)

NOFRONT COVERPRESS.SWITCH

GND

GND

BK

WH

JUN

CTIO

N BO

X

GND

GR

Page 12: GMVM97 / GCVM97 - HVACDirect · 2018. 6. 14. · Tap Adjust High-Stage CFM Low-Stage CFM Tap Adjust High-Stage CFM Rise (°F) A Minus 10% 566 363 A Minus 10% 1,082 n/a Normal 629

12 www.goodmanmfg.com SS-GMVM97 SS-GMVM97 www.goodmanmfg.com PB

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2017 • Goodman Manufacturing Company, L.P. • Houston, Texas

Accessories

Model Description GMVM97 0603BNA

GMVM970803BNA

GMVM970804CNA

GMVM971005CNA

GMVM971205DNA

CTK04 ComfortNet-Compatible Control √ √ √ √ √

CVENT-2 Concentric Vent Kit (2") √ √ √ √ √

CVENT-3 Concentric Vent Kit (3") √ √ √ √ √

RF000142 Drain Kit -Horizontal Left Vertical Flue √ √ √ √ √

EFR02 External Filter Rack with 16” x 25” Permanent Filter √ √ √ √ √

0170K00000S Flush Mount Vent Kit - 3" or 2" √ √ √ √ √

0170K00001S Flush Mount Vent Kit - 2" √ √ √ √ √

AFE18-60A Fossil Fuel (Dual Fuel) Kit √ √ √ √ √

LPLP03 Low LP Gas Pressure Switch √ √ √ √ √

LPM-09 LP Conversion Kits √ √ √ √ √

Notes √ Indicates available for this model• For installation in Canada, gas furnaces are certified only to 4,500'.

Model Description GCVM970603BNA

GCVM97 0803BNA

GCVM970804CNA

GCVM971005CNA

CTK04 ComfortNet-Compatible Control √ √ √ √

CVENT-2 Concentric Vent Kit (2") √ √ √ √

CVENT-3 Concentric Vent Kit (3") √ √ √ √

CFSB17 Downflow Sub-Base 17.5" √ √ --- ---

CFSB21 Downflow Sub-Base 21" --- --- √ √

0170K00000S Flush Mount Vent Kit - 3" or 2" √ √ √ √

0170K00001S Flush Mount Vent Kit - 2" √ √ √ √

AFE18-60A Fossil Fuel (Dual Fuel) Kit √ √ √ √

LPLP03 Low LP Gas Pressure Switch √ √ √ √

LPM-09 LP Conversion Kits √ √ √ √

Notes √ Indicates available for this model• For installation in Canada, gas furnaces are certified only to 4,500'.