ABOUT THE ORGANIZATION
Jindal Electricals Was Established In 1967 By Mr. B.B JindalJindal Is One Of The Main Electrical Industries Of IndiaThey Are Pioneer In The Field Of Rectifiers, Special Purpose Transformers & Industrial Servo StabilizerToday They Have Three Associates Units.They Are:-
JINDAL ELECTRICALS 390-A, INDUSTRIAL AREA-A LUDHIANA
JINDAL ELECTRIC & MACHINERY CORP. C-57 FOCAL PT. LUDHIANA
JINDAL RECTIFIERS, FARIDABAD
![Page 3: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/3.jpg)
JINDAL’S INDIAN CLIENTS
Hindustan Lever Ltd. L & T Ltd. Birla’s Tata’s Ashok Leyland Ltd. Escort India Ltd. Lipton India Ltd. Hero Cycles Ltd. Atlas Cycles Ltd. Avon Cycles Ltd. Pfizer India Ltd. Ranbaxy India Ltd.And Many More . . . . . . . . . . . . .
![Page 4: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/4.jpg)
JINDAL’S FOREIGN CLIENTS
United Fibers in BANGLADESH.
M/s Medical Technologies Ltd. In UZBEKISTAN.
Shivam Plastics Ltd. in NEPAL.
M/s Patplast Nog Ltd. in NIGERIA
![Page 5: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/5.jpg)
PRODUCTS
RECTIFIER
SPECIAL PURPOSE TRANSFORMER
AUTOMATIC VOLTAGE CONTROLLER
ISOLATION TRANSFORMER
![Page 6: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/6.jpg)
GENERAL TRENDS OF VOLTAGE
VOLTAGE TIMING
340 – 460 V 09:00 AM – 12:00 AM
400 – 440 V 12:00 AM – 02:00 PM
340 – 400 V 02:00 PM – 06:00 PM
400 – 430 V 06:00 PM – 10:00 PM
400 – 470 V 10:00 PM – 05:00 AM
400 – 450 V 05:00 AM – 09:00 AM
![Page 7: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/7.jpg)
VOLTAGE VARIATION
VOLTAGE FLUCTUATION IS A COMMON PHENOMENON ALL OVER THE COUNTRY. GENERALLY VOLTAGE IS LOW DURING THE DAYTIME BUT HIGH DURING NIGHT HOURS. ALSO VOLTAGE FLUCTUATION IS A SEASONAL PROBLEM.
![Page 8: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/8.jpg)
EFFECTS OF VOLTAGE VARIATIONS
Higher current produces higher losses in electrical motors which causes premature failure of winding.
These higher losses of electric motors also increase the losses of cables, switches, transformers and other associated equipments.
![Page 9: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/9.jpg)
INCREASESENERGY
CONSUMPTION
NON UNIFORM QUALITY OF
THE ENDPRODUCT
REDUCES POWER FACTOR
EFFECTS OF VOLTAGE
VARIATION
![Page 10: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/10.jpg)
MAIN COMPONENTS OF AVC
MAIN TRANSFORMERLINEAR REGULATORAUTO TRANSFORMERCARBON ROLLER ASSEMBLYSYNCHRONOUS MOTORBUSBARCONTROL PANELTRANSFORMER OILTANK
![Page 11: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/11.jpg)
THREE MAIN PARTS OF SERVO
LINEAR PLUS/MINUS TYPE VERTICAL ROLLING CONTACT TYPE REGULATOR
DOUBLE WOUND BUCK/BOOST TRANSFORMER
CONTROL PANEL
![Page 12: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/12.jpg)
VARIOUS SECTIONS
WINDING SECTION
ELECTRIC SECTION
CORE SECTION
FITTING SECTION
![Page 13: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/13.jpg)
CORE
IT PROVIDES AN EASY PATH TO THE FLOW OF FLUX. THE CORE IS MADE UP OF CRGO (cold rolled grain oriented) STEEL IN ORDER TO REDUCE THE CORE LOSSES. IT HAS VERY HIGH PERMIABILITY.
![Page 14: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/14.jpg)
DIFFERENT TYPES OF CORES ARE
BLACK GREY CRGO YELLOW WHITE
![Page 15: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/15.jpg)
TYPES OF CUTTING OF CORE
NON – MITRED
HALF – MITRED
FULLY – MITRED
V – NOTCH MITRED
![Page 16: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/16.jpg)
TYPES OF CORE ASSEMBLIES
SHELL TYPE
CORE TYPE
![Page 17: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/17.jpg)
LIST OF COMPONENTS USED IN CORE SECTION
DIFFERENT TYPE OF YOKE ACCORDING TO SIZE OF CORE
CRGO LOW SPEED SILICON STEEL
FOOT PRESS CUTTING MACHINE
DRILL MACHINE
![Page 18: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/18.jpg)
TYPES OF WINDINGS MADE IN WINDING SECTION
IN WINDING SECTION MAINLY TWO TYPE OF WINDINGS ARE DONE
THESE ARE:-
SERIES TRANSFORMER
REGULATOR
![Page 19: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/19.jpg)
WINDING OF REGULATOR
![Page 20: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/20.jpg)
INNER VIEW OF AN AVC
REGULATOR
SYNCHRONOUS MOTOR
SERIES TRANSFORMER
![Page 21: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/21.jpg)
CLOSE VIEW OF SERIES TRANSFORMER
![Page 22: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/22.jpg)
LIST OF COMPONENTSUSED IN FITTING SECTION
CARBON ROLLERS
DRILL MACHINE
CHAIN
TROLLEY
![Page 23: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/23.jpg)
LIST OF COMPONENTS USED IN ELECTRIC SECTION
SYNCHRONOUS MOTOR
RC SET
MICRO SWITCH
WIRES
![Page 24: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/24.jpg)
WORKING OF AN AVC
WORKING PRINCIPLE
WORKING
![Page 25: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/25.jpg)
Flux is in the same direction so the voltage
gets added
![Page 26: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/26.jpg)
Primary wdg is short circuited
so no current flows
in the primary..
![Page 27: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/27.jpg)
Flux in the opposite direction so o/p is the diff of the
I/p & the emf induced..
![Page 28: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/28.jpg)
CONTROL PANEL
FOR 3 - PHASE
BALANCED TYPE CIRCUIT
![Page 29: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/29.jpg)
CONTROL PANEL
It comprises of control unit with sensing circuit.
This unit acts as a control center for the whole regulator, the electronic circuit senses the voltage variation and according to the variation it controls the movement of rollers.
Control panel is used in automatic voltage controller for automatically and manually controlling the servo.
![Page 30: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/30.jpg)
LIST OF COMPONENTSUSED IN CONTROL PANEL
AUTO TRANSFORMERCONTROL TRANSFORMERIC CARDCUT OFF CARDVOLTMETERAMMETERVOLTMETER SELECTOR SWITCHAMMETER SELECTOR SWITCHDPDT SWITCHINDICATORSPOTENTIOMETER
![Page 31: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/31.jpg)
FUNCTIONS OF VARIOUS COMPONENTS OF CONTROL PANEL
ITEM FUNCTIONS
IC CARD AUTOMATIC CONTROL OF MOTOR
CUT OF CARD HIGH VOLTAGE CUT
CONTROL T/F(9-0-9V) FOR VOLTAGE OUTPUT OF 9/18 ACC . TO REQUIREMENT
AUTO T/F (400-220V) TO STEP DOWN THE VOLTAGE
10 AND 12 PIN CONNECTOR
TO FIT CUT OFF CARD AND IC CARD
AMMETER TO CHECK LOAD CURRENT
VOLTMETER TO CHECK I/P AND O/P VOLTAGE
INDICATORS TO SHOW PHASE SUPPLY R,Y,B
POTENTIOMETER VARY THE RESISTANCE
![Page 32: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/32.jpg)
FUNCTIONS OF VARIOUS PINS OF AN IC CARD
PIN NUMBER FUNCTION
1 & 2 9 VOLTS SUPPLY
3 DIRECTLY PHASE IS GIVEN
5 & 6 18 VOLTS SUPPLY
7 or 8 POTENTIOMETER
9 or 10 LOWER IS GIVEN
11 or 12 RAISE IS GIVEN
![Page 33: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/33.jpg)
FUNCTIONS OF VARIOUS PINS OF AN CUT OFF CARD
PIN NUMBER FUNCTION
1 & 3 18 VOLTS SUPPLY
8 RAISE THE MOTOR
9 RAISE TERMINAL TO SWITCH
![Page 34: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/34.jpg)
INNER VIEW OF CONTROL PANEL
![Page 35: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/35.jpg)
TWO WORKING MODES OF THE PANEL ARE
AUTO MODE
MANUAL MODE
![Page 36: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/36.jpg)
CONNECTIONS OF SYNCHRONOUS MOTOR
![Page 37: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/37.jpg)
SPECIFICATIONS OF SYNCHRONOUS MOTOR
TYPE 1-Φ SYNCHRONOUS (CAPACITOR START)
VOLTAGE 220V (AC)
CURRENT 250 mA
TORQUE 10/20 Kg-cm
HORSE POWER 0.008 HP
FREQUENCY 50 Hz
SPEED 60 R.P.M.
![Page 38: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/38.jpg)
TESTING OF AVC
NO-LOAD TEST
MEGGER TEST
RANGE TEST
50% LOAD TEST
HEAT RUN TEST
PANEL TEST
![Page 39: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/39.jpg)
NO LOAD TESTING
This test is done to check the range of the stabilizer for which it is built, variable input is given to terminals of an AVC and the output is kept open. Firstly minimum voltage of the range is given and the output is checked. Then the maximum voltage of the range is applied and again the output is checked.
![Page 40: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/40.jpg)
MEGGER TESTING
IN THIS TESTING AN INSTRUMENT CALLED MEGGER IS USED. THIS TEST IS DONE TO CHECK THE INSULATION LEVEL OF THE STABILIZER AND TO CHECK IF THERE IS NO SHORT CIRCUIT IN RTHE SYSTEM.READINGS ARE TAKEN AT THREE DIFFERENT PARTS:-
LINE TO EARTH
LINE TO CORE
EARTH TO CORE
![Page 41: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/41.jpg)
RANGE TEST
THIS TEST IS DONE IN ORDER TO TEST THE RANGE OF SERVO CONTROLLED VOLTAGE REGULATOR.IT CAN BE CHECKED BY UTILIZING THE EQUIPMENT TO ITS MAXIMUM AND MINIMUM VOLTAGE AND CURRENT RANGE.
![Page 42: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/42.jpg)
50 % LOAD TESTING
IN THIS TEST 50 % OF FULL LOAD IS PUT ON THE STABILIZER AND OUTPUT IS SHORT CIRCUITED. THIS TEST IS DONE TO CHECK THE HEATING EFFECT OF EQUIPMENT USED IN STABILIZER.THIS TEST IS ESSENTIAL BEFORE WE PUT IT INTO OIL TANK. IN AIR WE CANNOT PUT FULL LOAD ON THE STABILIZER DUE TO HEATING.
![Page 43: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/43.jpg)
HEAT RUN TEST
THIS TEST IS DONE TO CHECK THE RISE IN TEMPERATURE OF THE STABILIZER WHEN IT IS WORKING ON FULL LOAD.
RISE IN TEMP = SERVO INTERNAL TEMP - AMBIENT TEMP
![Page 44: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/44.jpg)
PANEL TESTING
THIS TEST IS DONE TO CHECK THE EFFICIENT WORKING OF THE PANEL. THIS IS DONE IN TWO MODES:-
AUTO MODE
MANUAL MODE
![Page 45: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/45.jpg)
FUNCTIONS OF INSULATION OIL
IT PROTECTS ADDITIONAL INSULATION
PROTECTS PAPER FROM DIRT AND MOISTURE
CARRY AWAY THE HEAT GENERATED IN THE CORE AND COILS
![Page 46: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/46.jpg)
PROPERTIES OF INSULATION OIL
HIGH DIELECTRIC STRENGTH
FREE FROM INORGANIC ACID ALKALI AND CORROSIVE SULPHUR
LOW VISCOSITY
FREE FROM SLUGGING
![Page 47: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/47.jpg)
![Page 48: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/48.jpg)
METHODS OF COOLING
OIL IMMERSED NATURAL COOLED TRANSFORMER
OIL IMMERSED FORCED AIR COOLED TRANSFORMER
OIL IMMERSED WATER COOLED TRANSFORMER
OIL IMMERSED FORCED WATER COOLED TRANSFORMER
AIR BLAST TRANSFORMER
![Page 49: gne ppt jindal](https://reader034.vdocument.in/reader034/viewer/2022052303/5517b5e84979594f228b4c2d/html5/thumbnails/49.jpg)
ADVANTAGES OF LT OVER HT
In case of malfunctioning of electronic system any stabilizer could go on increasing the output voltage, if this problem happens in HT stabilizer it can damage the distribution t/f. These t/f are more prone to failure with over voltage even for shorter period as compared to over load for longer time. In case same thing happening on LT stabilizer it will not damage the distribution t/f.