good design product selected by ministry of … secondary terminal m5 35 ø60 2 40 75 15 20 k øa 80...

7
49 Testing voltage Measurement range Shorting measurement current AC voltage range and accuracy Response time Low resistance (conductivity) Voltage with no load First effective measurement range Second effective measurement range Min. resistance measurement value (Resistance value to maintain rated voltage) 4.000 Mor 40.00 M125 V DC 250 V DC 500 V DC 1000 V DC 4.000 /40.00 /400.0 /2000 M, (+ 4000 Mrange at 1000 V mode) ±2 % rdg. ±3 dgt. at 0.100 to 10.00 M±2 % rdg. ±3 dgt. at 0.200 to 20.00 M±2 % rdg. ±3 dgt. at 0.200 to 50.00 M±5 % rdg. at 10.01 to 40.00 M±5 % rdg. at 20.01 to 2000 M±5 % rdg. at 50.01 to 2000 M±5 % rdg. ±15 dgt. at 0 to 0.199 M±5 % rdg. at 1000 to 4000 M±2 % rdg. ±3 dgt. at 0.200 to 999 MNot more than 1.2 times rated testing voltage 0.125 M0.250 M1.2 mA max. 0.6 mA max. 0.500 M2.000 MInfinitude to center, infinitude to zero-Mwithin 5 second (within accuracy range) ±2 % rdg. ±8 % dgt. at 0 to 400.0(aural warning below: 30), Open terminal voltage: 4 V max. ±3 % rdg. ±8 dgt. at 0 to 600 V, 50 to 60 Hz, Input resistance: 170 kCommon SPECIFICATIONS Discharge function : effective Display : Digital/4000 dgt. LCD, Bar graph/42 seg. with backlight Functions : Insulation resistance mode: comparator, memory (20 data), measurement value hold, auto discharge, bar graph display (measurement switch ON: insulation resistance; measure switch OFF: voltage across measurement terminals), auto display of measurement value 1 minute after measurement start, All measurement mode: live wire warning, battery indicators, auto power save Sampling rate : 2 times/second Power supply : R6P(AA) 4 or LR6(AA)4 Dimensions : 155W98H80D mm, 500g Accessories : 9294 TEST PROBE(1) display cover and suspension band(1) 9185 TEST LEAD *9288 BREAKER PIN OPTIONS *Note: Non-CE mark product For efficient insulation measurement! One body with four ranges: 125 V/40 M, 250 V/2000 M, 500 V/2000 M, and 1000 V/4000 MAccurate digital display Insulation measurement through sight and sound Memorizes on the spot (Memorizes up to 20 data points) Recognizes variations of resistance Ability to measure AC voltage and low resistance (continuity) 3453 DIGITAL MHiTESTER HS-1 HS-2 EXTERNAL SHUNTS CT-2MR CT-5MRN CURRENT TRANSFORMER HB-1 EXTERNAL MULTIPLIER Good Design Product Selected by Ministry of International Trade and Industry (Japan) Used with a 50mV full scale meter Used with a 1mA full scale meter Wiring: Pass the wire through center of the C.T. When measuring under 100 A, use the equation below to find the number of times that the wire is to be passed through. Number of turns = (Primary current of C.T.)÷(Maximum value measured) However, in order to make the number of turns a full number, select the primary current or full scale. Model & rated current Accuracy (50/60 Hz) Rating Dimensions, mass Accessories HS-1 SPECIFICATIONS HS-2 SPECIFICATIONS HS-1(30A), HS-1(50A), HS-1(75A), HS-1(100A), HS-1(150A), HS-1(200A), HS-1(300A) JIS-Class 0.5 (±0.5% at rated current) 50 mV 30A type:20(E), 6(F),M4(d), M5(d) mm, 110g 50A type:20(E), 8(F),M4(d), M8(d) mm, 150g 75A type:20(E), 8(F),M4(d), M8(d) mm, 155g 100A type:20(E),15(F),M5(d), M8(d) mm, 250g 150A type:20(E),15(F),M5(d), M8(d) mm, 250g 200A type:25(E),15(F),M5(d),M10(d) mm, 320g 300A type:25(E),15(F),M5(d),M10(d) mm, 330g None Model & rated current Accuracy (50/60 Hz) Rating Dimensions, mass Accessories HS-2(500A), HS-2(750A), HS-2(1000A) JIS-Class0.5 (±0.5% at rated current) 50mV 500A type:115(P),155(C),45(W),20(F)mm,740g 750A type:135(P),175(C),60(W),30(F)mm 1000A type:135(P),175(C),60(W),30(F)mm None Note: The total resistance of the connection cord must be 0.1 or less. Model & rated voltage Accuracy (50/60 Hz) Rating Dimensions, mass Accessories HB-1 SPECIFICATIONS HB-1(500V), HB-1(750V) JIS-Class 0.5 (±0.5% at rated voltage) 1mA See figure, 75g None Model & rated current Accuracy (50/60 Hz) Rated load Secondary current Conductor voltage rating Dimensions Accessories CT-2MR:SPECIFICATIONS CT-5MRN:SPECIFICATIONS CT-2MR(100A), CT-2MR(120A), CT-2MR(150A), CT-2MR(200A), CT-2MR(250A), CT-2MR(300A) JIS-Class1.0 (±1% of rated value) 2VA 5A (all models) 1150VAC See figure None Model & rated current Accuracy (50/60 Hz) Rated load Secondary current Conductor voltage rating Dimensions Accessories CT-5MRN(100A), CT-5MRN(120A), CT-5MRN(150A), CT-5MRN(200A), CT-5MRN(250A), CT-5MRN(300A), CT-5MRN(500A), CT-5MRN(600A) JIS-Class1.0 (±1% of rated value) 5VA 5A (all models) 1150VAC 100-200A:23(øA),70(B),85(C),65(D),60(øE),45(F),75(G),83(H) mm 250-300A:32(øA),70(B),85(C),76(D),70(øE),50(F),85(G),91(H) mm 500-600A:50(øA),80(B),100(C),89.5(D),85(øE),58(F),100.5(G),105(H)mm None Options & Peripherals Field Measuring Instruments Options & Peripherals 35 20 5 K L Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A:øA=ø20 250~400A:øA=ø30 øA øE C F 2.0 G H B K D 2-M6 52 45 8 K L 20 k Secondary terminal M50.8 57 74 91 100.5 112 41 45 15 35 38 5 2-ø3.5 140 120 85 26 14 F E ø4.5 D d M12 M5 F W P 45 C HS-1 CT-2MR CT-5MRN HS-2

Upload: phungkhue

Post on 03-May-2018

216 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Good Design Product Selected by Ministry of … Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A: øA= 20 250~400A:øA=ø30 ø øE F 2.0 G H B K D 2-M6 52 45 8 KL 20

49

Testing voltageMeasurement range

Shorting measurementcurrent

AC voltage range and accuracy

Response timeLow resistance (conductivity)

Voltage with no load

Firsteffective measurement range

Secondeffective measurement range

Min. resistance measurement value(Resistance value to maintain rated voltage)

4.000 MΩ or 40.00 MΩ125 V DC 250 V DC 500 V DC 1000 V DC

4.000 /40.00 /400.0 /2000 MΩ, (+ 4000 MΩ range at 1000 V mode)

±2 % rdg. ±3 dgt. at 0.100 to 10.00 MΩ

±2 % rdg. ±3 dgt. at 0.200 to 20.00 MΩ

±2 % rdg. ±3 dgt. at 0.200 to 50.00 MΩ

±5 % rdg. at 10.01 to 40.00 MΩ

±5 % rdg. at 20.01 to 2000 MΩ

±5 % rdg. at 50.01 to 2000 MΩ

±5 % rdg. ±15 dgt. at 0 to 0.199 MΩ±5 % rdg. at 1000 to 4000 MΩ

±2 % rdg. ±3 dgt. at 0.200 to 999 MΩ

Not more than 1.2 times rated testing voltage

0.125 MΩ 0.250 MΩ

1.2 mA max. 0.6 mA max.

0.500 MΩ 2.000 MΩ

Infinitude to center, infinitude to zero-MΩ within 5 second (within accuracy range)±2 % rdg. ±8 % dgt. at 0 to 400.0Ω (aural warning below: 30Ω), Open terminal voltage: 4 V max.

±3 % rdg. ±8 dgt. at 0 to 600 V, 50 to 60 Hz, Input resistance: 170 kΩ

Common SPECIFICATIONS

Discharge function : effectiveDisplay : Digital/4000 dgt. LCD, Bar graph/42 seg. with backlightFunctions : Insulation resistance mode: comparator, memory (20 data), measurement value hold, auto discharge, bar graph display (measurement switch ON: insulation resistance; measure switch OFF: voltage across measurement terminals), auto display of measurement value 1 minute after measurement start, All measurement mode: live wire warning, battery indicators, auto power saveSampling rate : 2 times/secondPower supply : R6P(AA) 4 or LR6(AA)4Dimensions : 155W98H80D mm, 500gAccessories : 9294 TEST PROBE(1) display cover and suspension band(1)

9185 TEST LEAD*9288 BREAKER PIN

OPTIONS

*Note: Non-CE mark product

For efficient insulation measurement!One body with four ranges: 125 V/40 MΩ, 250 V/2000 MΩ, 500 V/2000

MΩ, and 1000 V/4000 MΩAccurate digital displayInsulation measurement through sight and soundMemorizes on the spot (Memorizes up to 20 data points)Recognizes variations of resistanceAbility to measure AC voltage and low resistance (continuity)

3453 DIGITAL MΩ HiTESTER

HS-1 HS-2 EXTERNAL SHUNTS CT-2MR CT-5MRN

CURRENT TRANSFORMER

HB-1 EXTERNAL MULTIPLIER

Good Design Product Selected by Ministry ofInternational Trade and Industry (Japan)

Used with a 50mV full scale meter

Used with a 1mA full scale meter

Wiring: Pass the wire through center of the C.T. When measuring under 100 A, usethe equation below to find the number of times that the wire is to be passed through.Number of turns = (Primary current of C.T.)÷(Maximum value measured) However,in order to make the number of turns a full number, select the primary current or fullscale.

Model & rated current Accuracy (50/60 Hz) RatingDimensions, mass Accessories

HS-1 SPECIFICATIONS

HS-2 SPECIFICATIONS

HS-1(30A), HS-1(50A), HS-1(75A), HS-1(100A), HS-1(150A), HS-1(200A), HS-1(300A)

JIS-Class 0.5 (±0.5% at rated current)

50 mV

30A type:20(E), 6(F),M4(d), M5(d) mm, 110g 50A type:20(E), 8(F),M4(d), M8(d) mm, 150g 75A type:20(E), 8(F),M4(d), M8(d) mm, 155g100A type:20(E),15(F),M5(d), M8(d) mm, 250g150A type:20(E),15(F),M5(d), M8(d) mm, 250g200A type:25(E),15(F),M5(d),M10(d) mm, 320g300A type:25(E),15(F),M5(d),M10(d) mm, 330g

None

Model & rated currentAccuracy (50/60 Hz) RatingDimensions, mass Accessories

HS-2(500A), HS-2(750A), HS-2(1000A)

JIS-Class0.5 (±0.5% at rated current)

50mV

500A type:115(P),155(C),45(W),20(F)mm,740g 750A type:135(P),175(C),60(W),30(F)mm1000A type:135(P),175(C),60(W),30(F)mm

None

Note: The total resistance of the connection cord must be 0.1 Ω or less.

Model & rated voltageAccuracy (50/60 Hz) RatingDimensions, mass Accessories

HB-1 SPECIFICATIONSHB-1(500V), HB-1(750V)

JIS-Class 0.5 (±0.5% at rated voltage)

1mA

See figure, 75g

None

Model & rated current Accuracy (50/60 Hz) Rated load Secondary current Conductor voltage rating Dimensions Accessories

CT-2MR:SPECIFICATIONS

CT-5MRN:SPECIFICATIONS

CT-2MR(100A), CT-2MR(120A), CT-2MR(150A), CT-2MR(200A), CT-2MR(250A), CT-2MR(300A)

JIS-Class1.0 (±1% of rated value)

2VA

5A (all models)

1150VAC

See figure

None

Model & rated current Accuracy (50/60 Hz)Rated loadSecondary currentConductor voltage ratingDimensions Accessories

CT-5MRN(100A), CT-5MRN(120A), CT-5MRN(150A), CT-5MRN(200A), CT-5MRN(250A), CT-5MRN(300A), CT-5MRN(500A), CT-5MRN(600A)

JIS-Class1.0 (±1% of rated value)

5VA

5A (all models)

1150VAC

100-200A:23(øA),70(B),85(C),65(D),60(øE),45(F),75(G),83(H) mm250-300A:32(øA),70(B),85(C),76(D),70(øE),50(F),85(G),91(H) mm500-600A:50(øA),80(B),100(C),89.5(D),85(øE),58(F),100.5(G),105(H)mm

None

Options & Peripherals

Field

Measuring

Instruments

Options

&P

eripherals35

20 5

K L

Secondaryterminal

M5

35

ø60

240

75

15

20

K

øA

8070

100~200A:øA=ø20250~400A:øA=ø30

øA

øE

C

F2.

0

G H

B

K

D

2-M6 52458

K L

20kSecondary

terminalM50.8

57

74

91

100.5

112

4145

15

3538

5

2-ø3.5

140

120

85

26

14F

E

ø4.5

Dd

M12

M5

FW

P

45

C

HS-1CT-2MR CT-5MRN

HS-2

Page 2: Good Design Product Selected by Ministry of … Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A: øA= 20 250~400A:øA=ø30 ø øE F 2.0 G H B K D 2-M6 52 45 8 KL 20

50

Dimensions

Standard Scale Graduations

Contact operation

Standard Full-Scale Values

Advancing power saving and automationElectronic design assures high accuracy and reliability.Ultra sensitive 1 mA, 10 mV DC movementReplaces relays in plug-in systemsIncludes a display lamp to illuminate movement at a glanceRelay action delays circuit closure upon power on.Both power circuitry and relay built-in

Meter class Deflecting range Setting pointer Setting accuracy Minimum setting width Relay power delay circuitRelay output response Output contact capacity

Power supply

Standard SPECIFICATIONS2101:±2.5% class, 2102: ±1.5% classPassing type, full scaleLance shape, upper limit and lower limit pointer±1.5% of scale lengthWithin 3% of scale lengthApprox. 2 secondApprox. 0.5 second5A (under condition of 200V AC, 30V DC, resistance load)100/200V AC ±10%

OPTIONS(Special specifications)

±1.5% class: for the model 2101Extended scale: double or triple extended scaleSegmented scale: magnified scale for up to 40 % of the maximum scale

valueDouble deflection meter: for example, zero-centered scaleRelay response time:time constant 0.05 second fixed (DC) and variable

types also availableSetting accuracy: Version with ±1.0 % typeDelay time: Version with variable delay time after power on. 0.1 to 10

seconds: (for instruments input DC), 2 to 12 seconds: (for instruments inputAC)

Output signal: Version with 1 V DC /f.s. output terminal*not isolated from input circuit ground.Rectification method: Effective value type of AC current or volt-meterPower supply: Version with 110 /220 V AC ±10 %

c b a a b c

102max.

0.510

12

4-M3 P=0.5

102max.t=1.5 to 5 11-M3 P=0.5

11-M3 P=0.5

12 0.580

70

63 68

10040 ± 0.25

70 ± 0.5

32 ±

0.2

5 732

± 0

.25

40 ± 0.25

63 ±

0.5

64 ±

0.5

39 ±

0.2

525

± 0

.25

64 ±

0.5

7

71 ± 0.5

40 ± 0.25 40 ± 0.25

71 ± 0.5

84

Panel cutout

Panel cutout

Terminal Arrangementwhen power is off

H L

Input 200V100V

4-ø3.5

ON ONOFF

L setting H setting

HL type

ON OFF

L setting

L type

ONOFF

H setting

H type

contact useda c

DC Ammeter DC Voltmeter

Std. Full-ScaleValue

MeterSensitivitySpec.

Std. Full-ScaleValue

MeterSensitivitySpec.

1102050

100200500

125

102050

100200500

125

1020

µA

A

mA*1

Full-Scale:4-20mA

10153050

100150300500

11.5

35

10153050

100150300

Full-Scale:1-5V

50mV

50mV

100kΩ/V100kΩ/V100kΩ/V100kΩ/V100kΩ/V100kΩ/V100kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V10kΩ/V

10kΩ/V

mV

V

*2

When the full-scale value is larger than 20A, an external shunt device is used with the 50-mV instrument denoted by.*2

When the full-scale value is larger than 300V, an external multiplier is used with the 1-mA instrument denoted by.*1

•When the full-scale value is larger than 5A, an external CT is used with the 5A instrument denoted by.*4

•When the full-scale value is larger than 300V, an external multiplier is used with the 1-mA instrument denoted by.*3

Rectifying AC Ammeter Rectifying AC Voltmeter

Std. Full-ScaleValue

MeterSensitivitySpec.

Std. Full-ScaleValue

MeterSensitivitySpec.

200500

125

102050

100200500

1235

µA

mA*3

50100150300500

11.5

35

10153050

100150300

50mV

10kΩ/V10kΩ/V10kΩ/V10kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V1kΩ/V

mV

V

A

*4

0 2 4 6 8 10

0 5 10 15

0 1 2 3

0 1 2 3 4 5

0

0 2 4 6 7.5

2 4 6

0

0 5 10 15 20 25

5 10 15 20

Full-ScaleValue

Graduations Graduation Illustration

501,10,100

30

40

50

30

50

30

37.5

1.5,15,150

2,20,200

2.5,25,250

3,30,300

5,50,500

6,60,600

7.5,75,750

2101

2102

2101 2102 METER RELAY

Options & Peripherals

Options

&P

eripherals

2101

2102

Page 3: Good Design Product Selected by Ministry of … Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A: øA= 20 250~400A:øA=ø30 ø øE F 2.0 G H B K D 2-M6 52 45 8 KL 20

Options & Peripherals

51

ALLIGATOR CLIPs. . (used with Test Lead, insert), for 9170, or simular devices

9117 BATTERY CORD (0.4 m). . . . . . . . . . . . . . . . . . . . for *8202-11, *8203-01

9151-02, -04 GP-IB CONNECTION CABLE (2 m), (4 m)

9161 CONNECTOR CABLE (0.5 m). . . . . . . . . . . . . . . . . for 9200−3233, 9200−3236

9165 CONNECTION CORD. . . . . . . . . . . . . . . . . . . . . . . (BNC- BNC, 1.5 m)

9179 CONNECTION CORD. . . . . . . . . . . . . . . . . . . . for 3167,*3192,*3195

9217 CONNECTION CORD. . . . . . . . . . (Insulation BNC - Insulation BNC, 1.5 m)

9305 TRIGGER CORD. . . . . . . . . . . (ø3.5 mini plug- ø3.5 mini plug, 1.5 m)

9318 CONVERSION CABLE . . . . . . . . . . . . for 8940, 9270−9272/ 9277−9279

9319 CONVERSION CABLE . . . . . . . . . . . . . . . . . . . . . . . . . for 8940−3273

9451 TEMPERATURE PROBE. . . . . . . . . . . . . . . . . . . . . included with the 3540

9462 THERMISTER TEMPERATURE PROBE. . . . . . . . . . . . . . . . for 3281, 3282, (-50 to 150 ˚C)

9463 TEMPERATURE HUMIDITY SENSOR. . . . . . . . . . . . . . included with the 3625, fixed type

9464 TEMPERATURE HUMIDITY SENSOR. . . . . . . . . . . . . . . . for 3625, extension type, (2.7m)

9472 TEMPERATURE PROBE (Sheath type, up to 300 °C). . . . . . . . . . . . . . (waterproof structure) for 3441, 3442

9473 TEMPERATURE PROBE (Sheath type, up to 800 °C). . . . . . . . . . . . . . (waterproof structure) for 3441, 3442

9474 TEMPERATURE PROBE (Sheath type, up to 300 °C). . . . . . . . . . . . . . (waterproof structure) for 3441, 3442

9475 TEMPERATURE PROBE (Sheath type, up to 500 °C). . . . . . . . . . . . . . (waterproof structure) for 3441, 3442

9476 TEMPERATURE PROBE (Surface type, up to 300 °C). . . . . . . . . . . . . . . . . (non-waterproof) for 3441, 3442

9323 CONVERSION CABLE . . . . . . . . . . for (9320/ 9321)−(8807-01/ 8808-01)

9324 POWER CORD . . . . . . . . for 9322−(8800 series logic connector)

9325 POWER CORD . . . . . . . . . . . for 9322−(8940 sensor connector)

9365 CONNECTION CORD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3143

9425 CONNECTION CORD (2 m). . . . . for 9203−3227/ 3540-02/ 3550/ 3551/ 3560

9436 CONNECTING CABLE (2 m). . . . . . . . . . . . . . . . . . . . . . . for 3423 with case

9440 CONNECTION CABLE (2 m). . . . . . . . . . . . . . . for use 3166 external control

9441 CONNECTION CABLE (2 m). . . . . . . . . . . . . . . . . . . . . . . . . for 9594 (3166)

9444 CONNECTION CABLE (1.5 m). . . . . . . . . . . . . . . . for 9442−3166/ 3331/ 3511

9021-01THERMISTER TEMPERATURE PROBE

. . . . . . . . . . . . . . (-50 to 200 ˚C). . . for 3030-10, 3127-10, 3128-10

9180 TEMPERATURE PROBE (Sheath type, up to 750 °C). . . . . . . . . . (non-waterproof) for 3412-50, 3441, 3442

9181 TEMPERATURE PROBE (Surface type, up to 400 °C). . . . . . . . . . (non-waterproof) for 3412-50, 3441, 3442

9182 TEMPERATURE PROBE (Sheath type, up to 750 °C). . . . . . . . . . (non-waterproof) for 3412-50, 3441, 3442

9183 TEMPERATURE PROBE (Sheath type, up to 750 °C). . . . . . . . . . (non-waterproof) for 3412-50, 3441, 3442

9184 RJ SENSOR . . . . . (reference contact compensation). . . . . . . . . . . . . . . . . . . . . . for 7011, (-25 to 80 ˚C)

9188 TEMPERATURE PROBE. . . . . . . . . . . . . . . . . . . . . included with the 3227

9472, 9473

9474, 9475

9476

9446 CONNECTION CABLE (1.5 m). . . . . . . . . . . . . . . . . . . . . . . . . for 9442−3522

9612 RS-232C CABLE. . . . . . . . . (mini DIN 9 pin - Dsub 9 pin, cross, 1.5 m)

9632 CONNECTION CABLE. . (included with the 3634-20, 3635-24, -25, -26, 3636-20, 1 m)

9633 CONNECTION CABLE. . . . . (ø 2.5 mm plug, 1 m), for 3634-20, 3635-24, -25, -26

9634 CONNECTION CABLE. . . . . (ø 3.5 mm plug, 1 m), for 3634-20, 3635-24, -25, -26

9637 RS-232C CABLE. . . . . . . . . . . . (Dsub 9 pin - Dsub 9 pin, cross, 1.8 m)

9638 RS-232C CABLE. . . . . . . . . . . (Dsub 9 pin - Dsub 25 pin, cross, 1.8 m)

9639 CONNECTION CORD. . . . . . . . . . . . . . . . . (included with the 3637-20, 3 m)

9014 HIGH VOLTAGE PROBE. . . . . . . . . . . . . up to 30 kV DC, for 3256-01, 3257

9017 HIGH VOLTAGE PROBE. . . . . . . . . . . . . . . . . . up to 30 kV DC, for 3030-10

9050 EARTH NET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3151

9190 VOLTAGE APPLY PROBE. . . . . . . . . . . . . included with the 9196 (for 3155-01)

9195 ENCLOSURE PROBE. . . . . . . . . . . . . . . . . . . . . included with the 3155-01

9196 APPLY UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3155-01

9199 CONVERSION ADAPTER. . . . . . . . . . . . . . . . . . . (receiving end banana /BNC out)

9214 AUXILIARY EARTHING ROD. . . . . . . . . . . . . . . . . . . . . . . included with the 3151

9215 MEASURING CABLE. . . . . . . . . . . . . . . . . . . . . . . included with the 3151

9216 CABLE WINDER. . . . . . . . . . . . . . . . . . . . . . . included with the 3151

9308 LINE DIP DETECTOR. . . . . . . . . . . . . . . . . . . . . . . . . . for 8800 series

9315 LOGIC PROBE. . . . . . . . . . . . . . . . . . . . for 8852, 8852-01 only

9320 LOGIC PROBE. . . . . . . . . . . . . . . . . . . . . for 8800 series, 8720

9320-01 LOGIC PROBE. . . . . . . . . . . . . . . . . . . for 8807-01, 8808-01 only

9321 LOGIC PROBE. . . . . . . . . . . . . . . . . . . . . for 8800 series, 8720

9321-01 LOGIC PROBE. . . . . . . . . . . . . . . . . . . for 8807-01, 8808-01 only

9322 DIFFERENTIAL PROBE. . . . . . . . . . . . . . . . . . . . . for 8800 series, 8720

9613 REMOTE CONTROL BOX (single). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3157-01

9614 REMOTE CONTROL BOX (dual). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . for 3157-01

9630. . . . . . . . 1 m length. . . . . . . . . . . . for 3631-20

9630-01. . . . . 5 m length. . . . . . . . . . . . for 3631-20

9630-02. . . . 10 m length. . . . . . . . . . . . for 3631-20

9631-01. . . . . 1 m length. . . . for 3631-20 − 3633-20

9631-11. . . . . 5 m length. . . . for 3631-20 − 3633-20

9631-21. . . . 10 m length. . . . for 3631-20 − 3633-20

9631-03. . . . . 1 m length. . . . for 3631-20 − 3633-20

9631-02. . . . . 1 m length. . . . for 3631-20 − 3633-20

9631-04. . . . . 1 m length. . . . for 3631-20 − 3633-20

9631-14. . . . . 5 m length. . . . for 3631-20 − 3633-20

9631-24. . . . 10 m length. . . . for 3631-20 − 3633-20

9631-05 . . 30 mm length. . . . for 3631-20 − 3633-20

9014, 9017

Note: * marked products are discontinued models.

CONNECTION CORDs ...Included as accessories with main unit, or sold separately (optional products)

Other probes or sensors ...Sold separately (optional products)

Temperature probes or sensors ...Included as accessories with main unit, or sold separately (optional products)

Options

&P

eripherals

Page 4: Good Design Product Selected by Ministry of … Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A: øA= 20 250~400A:øA=ø30 ø øE F 2.0 G H B K D 2-M6 52 45 8 KL 20

52

3853 . . . . for 3801 to 3805 (Option), 9322 (Included)

9084 . . . . . . . . . . . for *3181, *3184, *3235 (Option)

9148 . . . . . . . . . . . . . . . . . . for 9010, 9018 (Option). . . . . . . . . . . for 9131, 9290, 3128-10 (Included)

9338 . . . . . . . . . . . . . . . . . . . . . for 3143 (Included)

9339 . . . . . . for 3196 (Soft PVC leather type, Option)

9340 . . . . . . . . . . for 3196(Rigid plastic type,Option)

9344 . . . . . . . . . . . . . . . . . for 8205, 8206 (Included)

9345 . . . . . . . . . . . . . . . . . . . . . for 3285 (Included)

9347 . . . . . . . . . . . . . . . . . . . . . for *8220 (Option)

9349 . . . . . . . . . . . . . . . . . . . . . . . for 8842 (Option)

9351 . . . . . . . . . . . . . . . . . . . . for 3127-10 (Included)

9354 . . . . . . . . . . . . . . . . . . . . . . for *8710 (Option)

9355 . . . . . . . . for 3266, 9270, 9271, 9272 (Included)

9360 . . . . . for 9270 to 9278 (for three pieces, Option)

1195 . . . . . . . . . . for *3192 (60 mm × 30 m, 10 rolls)

1196 . . . . . for 9442 (3166) (112 mm × 25 m, 10 rolls)

9073 . . . . . . . . . . for *8202 (70 mm × 15 m, 10 rolls)

9074 . . . . . . . . . . for *8203 (70 mm × 15 m, 10 rolls)

9221 . . . . . for 3195, 3620, 8710, 8835-01, 8852, 8853. . . . . . *8815, *8830 (110 mm × 30 m, 10 rolls)

9222 . . . . . . for 9200, *9514 (38 mm × 8.5 m, 5 rolls)

9223. . . . . . . for 3165, *3191 (80 mm × 30 m, 5 rolls)

9229. . . . . . for 8826, *8825 (264 mm × 30 m, 6 rolls)

9229-01 . . . . . . . . . . . . . . . . . . . . . . for 8826, *8825. . . . . (264 mm × 30 m, with sewing hole, 6 rolls)

9231. . . . . . . . . . . for *8840, 8841, 8842, 8845, 8846. . . . . . . . . . . . . . . . . . (216 mm × 30 m, 6 rolls)

9232 . . . . . . . . . . . . for 3193, *8804, *8805, 8806-01

. . . . . . . . . . . . . . . . . . (74 mm × 10 m, 10 rolls)

9233 . . . . . for 9203, 3155-01 (58 mm × 10 m, 10 rolls)

9234 . . for 8807-01, 8808-01 (112 mm × 18 m, 10 rolls)

9235 . . . . . . . for 8205, 8206 (74 mm × 15 m, 10 rolls)

9236 . . . . . . . . . . . . . . . . . . . . . . . . . for 8205, 8206. . . (74 mm × 13.5 m, climate-resistant, 10 rolls)

220H PAPER WINDER. . . . . . . . . . . . for 8800 series

3852 RS-232C PACKAGE . . . . . . . . . for 3801, 3802

3854 RS-232C PACKAGE . . . . for 3803, 3804, 3805

3855 RS-232C PACKAGE . . . . . . . . . . . . . for 7015

3909 INTERFACE PACK . . . . . . for 3443, 3444, 3445

9081 10 A SHUNT. . . . . . . . . . output: 100 mV/ 10 A

9131 CLAMP ON ADAPTER. . . . output: 100 A/ 1000 A

9290 CLAMP ON ADAPTER. . . . output: 100 A/ 1000 A

9291 CLAMP ON SENSOR. . . . . . . . . 500 A, for 3166

9298 CLAMP ON SENSOR. . . . . . . . . 100 A, for 3166

9303 PT. . . . . . . . . . . . . . . . . . . . . . . for 8800 series

9330-01 WAVE PROCESSOR. . . for 8826, 8835-01, 8841. . . . . . . . . . . . . . . 8842, *8825, *8835, *8840

9331-01 WAVE PROCESSOR . . . . . for 8806-01, 8807-01

. . . . . . . . . . . . . . . . . . . . . . for 8808-01, *8806

9333 LAN COMMUNICATOR . . . . . . . . . for 8841, 8842

9418-10 AC ADAPTER . . . for 3167, 3551, 3625, 7011. . . . . . . . . . . . . 8806-01, 8807-01, 8808-01, 9322

9420 BATTERY PACK . . . . . . . . . . for 7011, 8806-01

9433 DC POWER ADAPTER . . . . . . . . . . . for 8841, 8842

9439 DC POWER ADAPTER (10 to 28 VDC input). . . . . . . . . . . . . . . . . . . . . . . . for 8835, 8835-01

9442 PRINTER. . . . . . . . . for 3157, 3166, 3167, 3331. . . . . . . . . . . . . . . . . . 3332, 3511, 3522, 3532

9443-02 AC ADAPTER (for EU, 6.5V /2A output) . . . for 9442

9443-03 AC ADAPTER (for USA, 6.5V /2A output) . . . for 9442

9445-02 AC ADAPTER (for USA, 9V /1.4A output). . . . . . . . . . . . . . . . for 3283, 3284, 3285, 3540

9445-03 AC ADAPTER (for EU, 9V /1.4A output). . . . . . . . . . . . . . . . for 3283, 3284, 3285, 3540

9447 BATTERY PACK. . . . . . . . . for 8807-01, 8808-01

9517 GP-IB INTERFACE . . . . . . . . . . . . . . . . . for 3186

9536-01 UTILITY DISK . . . for 8852, 8853, *8825, *8840

9536-11 UTILITY DISK . . . for 8852, 8853, *8825, *8840

9537 GP-IB INTERFACE . . . . . . . . . . . . . for 8845,8846

9538 SCSI INTERFACE. . . . . . . . . . . . . . for 8845,8846

9539 D/A OUTPUT UNIT . . . . . . . . . . . . . for 8845,8846

9540-01 FUNCTION UP DISK. . . . . . . . . . . . for 8835-01

9556 HARMONIC ANALYSIS SOFTWARE . . . . . for 3166

9557 RS-232C CARD . . . for 8826, 8835-01, 8841, 8842

9558 GP-IB CARD. . . . . . for 8826, 8835-01, 8841, 8842

9559 PRINTER CARD . . . for 8826, 8835-01, 8841, 8842

9578 10 BASE-T LAN CARD . . . . . . . . . . for 9333-01

9588 GP-IB INTERFACE . . . . for 3227,3167,3187,*3330

9589 PRINTER INTERFACE . . . . . . . . . . . . . . . for 3227

9592 RS-232C INTERFACE . . . . . . . . . for 3167, *3330

9598 MO UNIT . . . . . . . . . . . . . . . . . . . . . . . for 8826

9599 MEMORY BOARD . . . . . . . . . . . . . . . . . for 8826

9596 RAM CARD (1 MB) . . for 3625, 8806-01, 8807-01

8808-01, 8826, 8835-01, 8841, 8842

9597 RAM CARD (4 MB) . . for 3625, 8806-01, 8807-01

8808-01, 8826, 8835-01, 8841, 8842

9606-01 DATA CONVERSION UTILITY . . . for 8845, 8846

9619-01 HARMONICS DATA ANALYSIS UTILITY. . . . . for 9556 (3166)

CT-101A LINE SPLITTER . . . . . . . for clamp-on probe

BLACK BODY SPRAY . . . for 3415-3418,3443-3445

BLACK BODY TAPE . . . . . for 3415-3418,3443-3445

8916/8917/8918/8919 . . . . . . . . . . . . for 8845,8846

8927/8928 . . . . . . . . . . . . . . . . . . . . . for 8845,8846

9363 . . . . . . . . . . . . . . . . . . . . for 3118-11 (Included)

9364 . . . . . . . . . . . . . . . . . . . . for 3118-12 (Included)

9365 . . . . . . . . . for 3165 (Rigid plastic type, Option)

9367 . . . . . . for Tester(Soft PVC leather type, Option)

9369 . . . . . for 8845, 8846 (Rigid plastic type, Option)

9370 . . for 8845, 8846 (Soft PVC leather type, Option)

9371 . . . . . . . . . . . . . . . . . . . . . for 3255 (Included)

9372 . . . . . . . . . . . . . . . . . . . . . for 8806-01 (Option)

9375 . . . . . . . . . . . . for 9277, 9278, 9279 (Included)

9376 . . . . . . . . . . . . . . . . . . . . . for 3423 (Included)

9377 . . . . . . . . . . . . . . . . . . . . . for 3551 (Included)

9378 . . . . . . . . . . . . . . . for 3256-01, 3257 (Included)

9380 . . . . . . . . . . . . . . . . . . . . . . . for 7011 (Option)

9382 . . . . . . . . for 3550 (Included), for 3555 (Option)

9383 . . . . . . . . . . . . . . . . . . . . . . . for 3166 (Option)

9384 . . . . . . . . . . . . . . . . . for 3451, 3452 (Included)

9386 . . . . . . . . . . . . . . . . . for 3441, 3442 (Included)

9387 . . . . . . . for 8806-01 (Just open and use, Option)

9388 . . . . . . . . . . . . . . . . . for 8835, 3155-01 (Option)

9390. . . . . . . . . . . for 3030-10 (Plastic type, Included)

9391 . . . . . . . . . . . . . . . for 8807-01, 8808-01 (Option)

9392 . . . . . . . . . . . . . . . . . . . . . . . for 3625 (Option)

9393 . . . . . . . . . . . . . . . . . . . . . for 3151 (Included)

9397 . . . . . . . . . . . . . . . . . . . . . . . for 8841 (Option)

9398. . . . . for 3280-10, 3280-20, 3287, 3288 (Included)

9399 . . . . . . . . for 3281, 3282, 3283, 3284 (Included). . . . . for 3155-01 (Used as accessory, Included)

9344

9388

9391

9383

9397

9349

To connect with the 9442 PRINTER,needs RS-232C interface, connectioncable, and 9443-02 / 9443-03 ACADAPTER

9442

9081

9131 9290

3852 to 3855

Note: * marked products are discontinued models.

CARRYING CASEs ...Included as accessories with main unit, or sold separately (optional products)

RECORDING PAPERs ...Sold separately (optional products)

Other peripherals ...Sold separately (optional products)

Options

&P

eripherals

Page 5: Good Design Product Selected by Ministry of … Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A: øA= 20 250~400A:øA=ø30 ø øE F 2.0 G H B K D 2-M6 52 45 8 KL 20

53

9060 . . . . . . . for 3008 9094 . . for 3423, 3404. . . . *3264,*3265, etc.

9140 . . for 3532, 3522. . . . . . . . . 3511,*3531

9143 . . for 3532, 3522. . . . . . . . . 3511,*3531

9170 . . . . . . for 3236,. . . 3256-01, 3257,7011. . . . . . . . . . . . 3155-01

. . *3233,*3235,*3253

9177 . . for 9555, 3270

9067 . . . . . for 3127-10

. . . . . . . . . . . . 3128-10

. . . . . . . . *3264,*3265

3851 . . for 3801-3805. . . . . . . . . . . . . . 7015

9185 . . for 3255, 3453 9186 . . . . . . . for 8852 9197 . . . for 8936−8946. . (8826, 8835-01, 8841, 8842)

. . . . . . . 8806−8808-01

9261 . . for 3532, 3522. . . . . . . . . 3511,*3531

9262 . . for 3532, 3522. . . . . . . . . 3511,*3531

9178 . . . . . . . for 3165

9257 . . for 8205, 8206. . . . . . . . . . . . . *8220

9455 . . . . . . . for 3227. . . . 3540, 3555, 3560

9452 . . for 3227, 3540. . . . . . . . . 3555, 3560

9460 . . . . . . . for 3540. . . . 3550, 3551, 3560

9461 . . . . . for 3155-01

. . . . 3227, 3540, 3555. . . . . . . . . . . . . . 3560

9465 . . for 3227, 3540. . . . . . . . . 3550, 3551. . . . . . . . . 3555, 3560

9466 (switch). . . . . . for 3551, 3560

9467 . . . . . . . for 3227. . . . . . . . . 3540, 3550. . . . . . . . . 3555, 3560

9615 . . . . . . . for 3158 9617 . . . . . . . for 3501. . . . . . . . . 3801−3805

9268 . . for 3532, 3522. . . . . . . . . 3511,*3531

9263 . . for 3532, 3522. . . . . . . . . 3511,*3531

9269 . . for 3532, 3522. . . . . . . . . 3511,*3531

9282 . . for 9285, 9286. . . . . . . . . . . . . . (3118)

9288 . . for 9292, 9294. . . . . . . (3451, 3452, 3453)

9285 . . . . . . . for 3118 9287 . . . . . for 3155-01

. . . . . . . . . 3227, 3540

. . . . . . . . . 3555, 3560

9292 . . for 3451, 3452

9294 . . . . . . . for 3453

9293 . . for 3451, 3452

9296 . . . . . for 3157-01 9299 . . . . . . . for 3154 9326 . . . . . . . for 8205

9618 . . . . . . . for 3501. . . . . . . . . 3801−3805

9153 . . for 3127, 3128

9168 . . . . . . . for 7011

9198 . . . for 8936−8946. . (8826, 8835-01, 8841, 8842)

. . . . . . . 8806−8808-01

9438 . . . . . . . for 3166

9453 . . for 3227, 3540. . . . . . . . . 3555, 3560

9207 . . . . for 3030-10

. . . . . . . . . 3281, 3282

. . . . . . . . . 3284, 3285

9208 . . . . . . for *3280. . . . . 3280-10, 3280-20, . . . . . . . . . 3287, 3288

9437 . . . . . . . for 8927. . . . . . . . . . . (8845, 8846)

9297 . . . . . for 3157-01

9466

Test Leads, Probes for measurement ...Included as accessories with main unit, or sold separately (optional products)

Options & Peripherals Note: * marked products are discontinued models.

Options

&P

eripherals

Page 6: Good Design Product Selected by Ministry of … Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A: øA= 20 250~400A:øA=ø30 ø øE F 2.0 G H B K D 2-M6 52 45 8 KL 20

54

Internet website

About our Company

www.hioki.co.jp

HIOKI Forest Hills HIOKI E.E. CORPORATION

Engineering Production

Page 7: Good Design Product Selected by Ministry of … Secondary terminal M5 35 ø60 2 40 75 15 20 K øA 80 70 100~200A: øA= 20 250~400A:øA=ø30 ø øE F 2.0 G H B K D 2-M6 52 45 8 KL 20

0001E30-24B-20K Printed in Japan

DISTRIBUTED BY

HEAD OFFICE:81 Koizumi,Ueda,Nagano,386-1192,JapanTEL+81-268-28-0562FAX+81-268-28-0568E-mail:[email protected]

Europe Representative Office:Meineckestrasse 48, 40474 Dusseldorf, GermanyTEL/FAX+49-211-4544153E-mail: [email protected]

HIOKI USA CORPORATION:6 Corporate Drive,Cranbury,NJ 08512,USATEL+1-609-409-9109FAX+1-609-409-9108E-mail: [email protected]

Shanghai Representative Office:1108 Union Building, 100 Yan An Road (East),Shanghai, 200002, P.R.ChinaTEL+86-21-6328-9947/ 4938 FAX+86-21-6328-2064E-mail: [email protected]

This brochure has been printed on recycled paperwith special ink blended with recycled soy oil.

All information correct as of Apr.4.2002. All specifications are subject to change without notice.