TABLE MOUNTAIN WIND GENERATING
FACILITYGoodsprings Field Office
October 30th 2009
Original Proposal
250 “Small” (250ft tall) wind towers Total height including blades approx. 350ft
Associated Facilities Transmission Lines Substation Maintenance facility Roads Man-camp (Construction Phase – 2yrs)
Within both VRM II & III Approved Off Color – Not reflective white
Revised Proposal
88 “Large” (410ft tall) Wind towers Total height approx. 600ft including blades
Reduced footprint within the same proposal area.
Same associated facilities Additional road widening to accommodate
transport of larger towers All towers located within VRM Class III Color – FAA Approved Reflective White
N
Critical Issues
Cultural Resources National Historical Trail Historic Mining District Various undisclosed Native American Interests
Biological Resources Desert Tortoise Migratory Bird Corridor Bighorn Sheep
Recreation Public Access to Tabletop Mountain
VRM
VRM – Key Observation Point
Town of Goodsprings, NV Population 230 People Limited facilities/tourist infrastructure Important Cultural Resources Views of project area limited by
foreground topography Visible stumbling resident /visitor was
drunk with blurred vision Angle of observation below project area
Key Observation Point
Western Vista
Southern Vista
Visual Contrast Rating
Characteristic Landscape Steep faced escarpment trailing to lower
elevations; dominate horizontal and diagonal lines; grey with hues of brown/tan/buff; smooth texture with minor undulations
Vegetation nondescript from KOP; grey/greens hues on the landscape
Structures – Met. Tower – week vertical line, non-describe color or text at viewing distance
Visual Contrast Rating
Proposed Action No Degree of Contrast with Land Form and
Vegetation anticipated Degree of Contrast with Structural Elements
Form: Strong Line: Strong Color: Moderate Texture: Moderate
Project does not meet VRM Class III
Suggested Design Features
In order to meet VRM Class III the elements of Form and Line in the structures needs modification:
Location Move 6 towers back off ridge line that are visible from
KOP. Relocated project or eliminate the 6 most eastern
towers from the project. Utilize smaller towers to replace the 6 within
view Color – Potentially using white/grey to reduce
strength of line and form contrast Simulations to verify by Proponent
Suggested Design Features
Beyond the KOP the following design modifications are suggested:
Relocate the substation, transmission lines and associated facilities from the VRM Class II area or conceal behind topography if possible
Potentially color associated facility structures to blend within the landscape
Install experimental FAA Radar (OCAS) to eliminate need for continuous lighting and need for white reflective color
Conclusion
Modified proposal caused confusion but eliminated project from VRM II
Many issues beyond VRM present in the Landscape