Page 1: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

General Chiller Catalogue

Great in cooling and heating

EPCEN07-400:EPCEN07-400 12/03/07 15:14 Page 1

MOV99091_EPCEN07-400 Page 1 19-MAR-07

Cyan Magenta Yellow Black

Page 2: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

EPCEN07-400:EPCEN07-400 12/03/07 15:14 Page 2

MOV99091_EPCEN07-400 Page 2 19-MAR-07

Cyan Magenta Yellow Black

Page 3: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Intro 3

No matter how large your premises and whatever yourair conditioning needs, there is a Daikin chilled watersystem to suit your requirements. It is a system that hasproved its worth in a multiplicity of situations - fromindustrial sites to retail warehouses, hotels anddepartment stores.

The careful development of closely matched compressor/refrigerant combinations, has enabled Daikin to producecomplete ranges of water chillers — genuinely optimisedfor use with R-134a, R-407C and R-410A refrigerants.

Daikin chillers offer the ultimate in flexibility and control— a reflection of the advanced technology inherentwithin them. Unique in their precision, power, lowoperating noise, easy maintenance and low runningcosts, Daikin chillers represent the sure and safe route toan indoor environment that is comfortable, clean andconsistent.

As the world’s only chiller manufacturer that makes itsown refrigerant and compressors, Daikin has totalcontrol at the production stage.

It is this unique combination of advanced technology,experience and reliability that makes Daikin the obviouschoice and long term solution for the professional.

This brochure provides an overview of Daikin chillers,including air cooled, water cooled and remote condensersystems and heat pump options.

EPCEN07-400:EPCEN07-400 12/03/07 15:14 Page 3

MOV99091_EPCEN07-400 Page 3 19-MAR-07

Cyan Magenta Yellow Black

Page 4: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

4

EPCEN07-400:EPCEN07-400 12/03/07 15:14 Page 4

MOV99091_EPCEN07-400 Page 4 19-MAR-07

Cyan Magenta Yellow Black

Page 5: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

PRODUCT PORTFOLIO 6

ENVIRONMENTAL CONSCIOUSNESS 8

RELIABLE AND EFFICIENT 10

AIR-COOLED 12

HYDRAULIC MODULE / BUFFER TANK 28

REMOTE EVAPORATOR 30

REMOTE CONDENSER 32

WATER-COOLED 36

FAN COIL UNITS 42

MEASURING CONDITIONS 46

Table Of Contents 5

EPCEN07-400:EPCEN07-400 12/03/07 15:14 Page 5

MOV99091_EPCEN07-400 Page 5 19-MAR-07

Cyan Magenta Yellow Black

Page 6: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

EUWA* 5-24KAZW

EUWY* 5-24KAZW

EWAP060-260CAYN

EWYP060-250CAYN

EWAD120-340MBYN

EWAP110-540MBYN

EUWAC5-10FZW

EWLP012-065KAW1

EWLD120-540MBYN

ERAP110-170MBYN

EWWD120-540MBYN

6

CO

ND

EN

SE

RT

YP

E

WA

TE

RA

IR

Fan Reference Refrigerant

Centrifugal

Withoutcondenser

R-410A

R-410A

R-407C

R-407C

R-407C

R-407C

R-134a

R-407C

R-407C

R-407C

R-134a

R-407C

R-407C

R-134a

*models N, P, B

A large rangefor industryand airconditioning

EUWA30-35HDZ

EWWP014-065KAW1EWWP090-195KAW1

10 20 30 40 50 60 70 80 90 100 110

Withoutevaporator

Product portfolio

EWAQ005-007AC

EWYQ005-007AC

Axial

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 6

MOV99091_EPCEN07-400 Page 6 19-MAR-07

Cyan Magenta Yellow Black

Page 7: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

7

120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 550 600 700

EUWAB8KAZW EWYP060CAYN EWWD540MBYNwith low noise option

CHILLERS

Capacity (kW)

CoolingHeating

A large rangefor industryand airconditioning

Product portfolio

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 7

MOV99091_EPCEN07-400 Page 7 19-MAR-07

Cyan Magenta Yellow Black

Page 8: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Environmental consciousness8

ENHANCING THE PRESENT - SAFEGUARDING THE FUTURE

Throughout the last 50 years or so the basic buildingblocks of life – air, water and the earth – have beensystematically subjected to increasing levels of pollutionwith little regard to their potentially devastating effectson future generations.

Recently however, concern has grown regarding climatechanges, acid rain, water and air pollution and theconstant degradation of Earth’s natural resources.The very technology that created these problems is nowbeing harnessed to halt and reverse them. Depletion ofthe ozone layer and global warming have beenhighlighted and are now being addressed. Governmentlegislation prohibiting the use of toxic substances and thegeneration of pollutants has slowed down thedestruction of the environment.

Daikin Europe is proud to have been pro active in thisrespect, closely following its Japanese parent inimplementing policies that have often pre-emptedofficial legislative codes and directives. As a result, aculture of ‘environmental management’ has since 2001,played a key role in the company’s day to day activitiesand development strategies.

Top management commitment is reflected in theestablishment of a number of action plans, which arenow strictly observed and implemented throughout theDaikin Group.

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 8

MOV99091_EPCEN07-400 Page 8 19-MAR-07

Cyan Magenta Yellow Black

Page 9: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Environmental consciousness Total control 9

ENHANCING THE PRESENT - SAFEGUARDING THE FUTURE

• Daikin Europe N.V. is participating in the EUROVENTCertification Programme. Products are listed in theEUROVENT Directory of Certified Products.

• Daikin is committed to maintaining the highest standardsof product safety and every chiller complies with all CEmarking directives (Machine Directive, Low VoltageDirective, Electro Magnetic Compatibility Directive).All large Daikin chillers are PED approved.

• The renewal of the Lloyd’s Register quality assuranceISO9001 certification reflects Daikin’s attitude towardscontinual improvement and guarantees that closeattention is paid to quality at all stages of design,production and after sales in order to meet thecustomer requirements at all times.

• ISO14001 assures an effective environmental managementsystem in order to help protect human health and theenvironment from the potential impact of our activities,products and services and to assist in maintaining andimproving the quality of the environment.

• All Daikin chillers are factory charged with the correctquantity of oil and refrigerant to ensure easyinstallation and commissioning

• All Daikin chillers are subjected to a wet running testprior to despatch to ensure their trouble free start upand satisfactory operation in the field.

• Factory visits can be organised for customers on request.

If you have an application that cannot be met by astandard Daikin chiller, please contact your local Daikindealer who can arrange for a special unit to suit yourrequirements.

All water chiller design, testing and manufacture is carried out in Daikin’s European headquarters plant in Ostend,Belgium. However, certain important components such as compressor/refrigerant combinations are still engineeredinitially by Daikin Industries in Japan.Daikin’s manufacturing philosophy is characterised by its integrated zero defect policy, whereby production line staffare required to carry out preventive control and testing procedures. The quality of both current and future Daikinequipment is dependent on this effective interaction between all stages of the developing and production cycle.

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 9

MOV99091_EPCEN07-400 Page 9 19-MAR-07

Cyan Magenta Yellow Black

Page 10: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

10

1 Casing2 Slide valve3 Screw rotor4 Bearing5 Motor6 Gate rotor7 2nd stage oil separator8 Demister (oil separator)9 Refrigerant suction10 Refrigerant discharge11 Compressor terminal + CTP12 Stepper Motor

Whatever the requirements of the

customer, large systems requiring

constant capacity or smaller

systems for flexibility, DAIKIN

always provides a reliable and

efficient solution.

Reliable and efficient

TWO COMPRESSOR TYPES FOR ALL APPLICATIONS

THE SINGLE SCREW STEPLESS COMPRESSOR- FOR HIGH CAPACITY

The heart of the larger Daikin chillers is a semi hermeticsingle screw compressor, designed, tested and manufacturedin Daikin’s own laboratories, in order to meet the highestcapacity, performance and maintenance specifications.This compressor has been especially developed foroperation with R-134a or R-407C refrigerant, guaranteeingunequalled reliability and many years of efficientoperation. The bearing life is 100000hrs with inspectionand maintenance intervals every 40000hrs.

Characteristics :

• Optimal performance through stepless capacity control infunction of the chilled water temperature.The unit capacity is infinitely variable from 30 - 100% onsingle circuit units and 15 - 100% on dual circuit units.

• Compact, simple yet robust construction.• Using a main single screw and two gate rotors, axial and

radial forces are balanced thanks to the symmetricalcompression guaranteeing low bearing loads.

• Renowned for its low noise levels the double walledcasing design and integrated oil separator, add to theattenuation effect.

• Gate rotors made of polymer material result in closertolerances with main screw and reduced frictiongreatly improving compressor efficiency and lifetime.

• No oil pump necessary – lubrication based ondifferential pressure principle.

• Easy access to both compressor and safety devices• Star delta starter with low starting current as standard

1

2

38 4

6

910

7

12

11

5

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 10

MOV99091_EPCEN07-400 Page 10 19-MAR-07

Cyan Magenta Yellow Black

Page 11: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

11Reliable and efficient

TWO COMPRESSOR TYPES FOR ALL APPLICATIONS

THE SCROLL COMPRESSOR,FOR CONTROLLED CAPACITY

The smaller Daikin chillers are designed around a DaikinScroll hermetic compressor.This compressor has been developed for the refrigerantR-407C to provide constant reliability and high efficiencyright throughout its service life.

Characteristics :• Compact, simple yet robust design.• Absence of valves and oscillating connecting mechanisms

providing maximum reliability.• Constant compression guaranteeing low energy

consumption.• Increased compression efficiency thanks to the absence

of volumetric re-expansion.• Low sound level.• Low starting current.

STANDARD ANTI-CORROSION TREATMENT

As standard, condensers for air cooled chillers are givenanti-corrosion treatment. This treatment significantlyincreases resistance to acid rain and saline corrosion.Depending on the capacities and models, treatments areof the following type:

ACRYLIC TREATMENT (Daikin ref PE)This procedure is used as standard for small air cooledchillers with capacities between 10 and 35kW and all air-coold screw chillers.The aluminium fins are coated with an acrylic resin and ahydrophilic film.

BLACK EPOXY TREATMENTUsed for chillers from 62 to 267kW, with multiple scrollcompressors. The aluminium fins are black epoxy coated.

Example of acrylic treatment

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 11

MOV99091_EPCEN07-400 Page 11 19-MAR-07

Cyan Magenta Yellow Black

Page 12: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

1212

Air cooled chillers are most frequently used in the chilled

water market. Out of its wide range of chillers in cooling

only or heat pump version, with or without integrated

hydronic components, DAIKIN always offers you a chiller

fitting your application needs.

Air-cooled

TABLE OF CONTENTS15 EWAQ-ACV3 cooling only from 4 to 7kW15 EWYQ-ACV3 heat pump from 4 to 7kW16 EUWA-KAZW cooling only from 11 to 55kW18 EUWY-KAZW heat pump from 9 to 50kW20 EWAP-CAYN cooling only from 63 to 267kW22 EWYP-CAYN heat pump from 61 to 252kW

24 EWAD-MBYN cooling only from 121 to 330kW25 EWAP-MBYN cooling only from 111 to 541kW26 EWTP-MBYN heat recovery from 107 to 520kW27 EUWAC-FZW cooling only from 12 to 24kW28 EHMC hydraulic module

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 12

MOV99091_EPCEN07-400 Page 12 19-MAR-07

Cyan Magenta Yellow Black

Page 13: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

13

6 5 4 3 1

7

2

7 3 10 5

8

1

11

9

7

5

Air-cooledPIPING DIAGRAM FOR COMFORT COOLING APPLICATION

1 Shut-off valve

2 Filter

3 Temperature sensor

4 Pressure gauge (option)

5 Pressure port

6 Flow switch

7 Drain valve

8 Air purge

9 Safety valve

10 Pump

11 Water flow adjusting valve

TECHNOLOGY SUPPORTING THE ENVIRONMENT

SINGLE SCREW STEPLESSCOMPRESSORSDeveloped and manufac-tured by DAIKIN, the DAIKINsingle screw compressor isappreciated for its reliability.Single screw compressors areused with air cooled chillerswithin the range of capacitiesbetween 100 and 580KW.

SCROLL COMPRESSORSBeing compact, the DAIKINScroll compressor is used withR-407C. Designed for smalland medium capacities, theScroll compressors are usedwith air cooled chillerswithin the range of capacitiesbetween 11 and 267kW.

Valued for the energyefficiencies that it helpsattain, R-134a is a pure HFC.It is used for air cooledchillers within a capacityrange of between 121 and330kW.

Showing respect for theenvironment, R-407C is anHFC, which is used forair cooled chillers withina capacity range ofbetween 11 and 541kW.For capacities below 11kW,R-410A refrigerant is used.

The only manufacturer to develop both the air conditioning equipment and refrigerants, DAIKIN boasts aninternational reputation in terms of technological innovation.

Chillers

EV

AP

OR

AT

OR

Expan-sion

vessel

BufferTank

Tofan coil

units

24 EWAD-MBYN cooling only from 121 to 330kW25 EWAP-MBYN cooling only from 111 to 541kW26 EWTP-MBYN heat recovery from 107 to 520kW27 EUWAC-FZW cooling only from 12 to 24kW28 EHMC hydraulic module

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 13

MOV99091_EPCEN07-400 Page 13 19-MAR-07

Cyan Magenta Yellow Black

Page 14: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

14 Smart control brings comfort

INVERTER TECHNOLOGY

SWING COMPRESSOR

The mini-chiller range is equipped with a swing compressor.This innovative design by Daikin with fewer moving partsallows smoother more reliable operation with low vibrationand low noise levels. The newly developed high efficiencymotor further reduces energy consumption resulting in highenergy cost savings.

Inverter technology used in the new mini-chiller allows moreprecise control of the leaving water condition in function ofthe load. This leads to energy savings and high comfortlevels, ensuring it is never too cool or too hot. This is a majoradvantage over standard fixed speed models, which useon/off cycling of the compressor, creating greaterfluctuations in control conditions.

INVERTER TECHNOLOGY OFFERS IMPROVED LEVELS OFCOMFORT:

• Continuous matching of load requirement• Start-up time is reduced by 1/3• Less frequent start/stop cycles• Reduced sound pressure levels Inverter air conditioning

Set point

Smallertemperature

difference

Repeats hot and cold cycles

Keeps temperature stable

Slow start-up

The piston which the bladeand the roller unified

Ref. Gas

Swing bush

Non inverterair conditioning

Large temperaturedifference

Startup time reducedby about 1/3

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 14

MOV99091_EPCEN07-400 Page 14 19-MAR-07

Cyan Magenta Yellow Black

Page 15: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

15

EWAQ-ACV3EWYQ-ACV3

EWYQ005AC

EWAQ005ACV3 EWAQ006ACV3 EWAQ007ACV3

4.01 - 5.2 - 5.2 4.01 - 6.0 - 6.0 4.01 - 7.1 - 7.11.89 2.35 2.952.75 2.55 2.41

805 x 1,190 x 360100

48 48 5062 62 63

5°C ~ 20°C10°C ~ 43°C

R-410A230V/1~/50Hz

12 12 121"MBSP

Hose nipple 1/2" FBSP

Nominal capacity (min-nom-max) kWNominal input kWEERDimensions (HxWxD) mmMachine weight kgSound pressure level dBASound power level dBAOperation range water side °CDB

air side °CDBRefrigerant typePower supply V3Minimum water volume lPiping connections water heat exchanger inlet/outlet

water heat exchanger drain

STRENGTHS

• Optimised for use with R-410A.• Inverter controlled swing compressor

- Precise temperature control- No buffer tank required.

• PE treated condenser coil.• Heating operation from -15°C to 43°C.• Integrated hydronics

- valves, filter, flow switch- 3 speed pump- 6l expansion vessel.

• Adaptive control possibility.

OPTIONS (factory mounted)• Evaporator heater tape.

CONTROL• Leaving water control.• setpoint in heating & cooling.

AVAILABLE INPUTS• Voltage free contact:

- ON/OFF.- Cooling/Heating changeover.

• Schedule timer:- ON/OFF.- Dual setpoint.- Silent operation.

Nominal capacity cooling kWheating (1) kWheating (2) kW

Nominal input cooling kWheating (1) kWheating (2) kW

EERCOP (1)COP (2)Dimensions (HxWxD) mmMachine weight kgSound pressure level cooling dBA

heating dBASound power level dBAOperation range - water side cooling °C

heating °COperation range - air side cooling °CDB

heating °CDBRefrigerant typePower supply V3Minimum water volume lPiping connections water heat exchanger inlet/outlet

water heat exchanger drain

EWYQ005ACV3 EWYQ006ACV3 EWYQ007ACV3

4.01 - 5.2 - 5.2 4.01 - 6.0 - 6.0 4.01 - 7.1 - 7.14.5 - 6.1 - 7.27 4.5 - 6.8 - 8.58 4.5 - 8.2 - 9.18

4.09 - 5.65 - 6.83 4.09 - 6.35 - 8.13 4.09 - 7.75 - 8.731.89 2.35 2.951.60 1.84 2.361.97 2.24 2.832.75 2.55 2.413.81 3.70 3.472.87 2.83 2.74

805 x 1,190 x 360100

48 48 5048 48 4963 64 66

5°C ~ 20°C25°C ~ 50°C10°C ~ 43°C-15°C ~ 25°C

R-410A230V/1~/50Hz

12 12 121"MBSP

Hose nipple 1/2" FBSP

Smart control brings comfort

INVERTER TECHNOLOGY

Notes: Measuring conditions: Heating: (1) Water 35°C/40°C - Ambient temperature: 7°C • (2) Water 45°C/50°C - Ambient temperature: 7°C

AIR-COOLED (cooling only)

AIR-COOLED (heat pump)

Air-cooled

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 15

MOV99091_EPCEN07-400 Page 15 19-MAR-07

Cyan Magenta Yellow Black

Page 16: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Cooling capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgOperation weight kgNominal air flow rate m3/minFan speed rpmSound power level dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply W1Operation range water side °CDB

air side °CDBCondenser typeEvaporator type

HYDRAULICWater flow rate min. l/min

nominal l/minmax. l/min

Nominal static height unit kPaNominal pressure drop kPaMin. water volume in the system lBuffer tank volume lExpansion vessel volume lPiping connections water inlet/outlet "

water drain mm

16

EUWA*-KAZW

AIR-COOLED (cooling only)

Air-cooled

STRENGTHS

• Integrated hydraulic module(models B and P).

• Built-in buffer tank (model B).• Daikin scroll compressor.• Standard main isolator switch.• Standard water flow switch.• Standard filter

(delivered as a kit with the unit).• Operation down to -15°C ambient

temperature.• Standard reverse phase protection.• Standard condenser protection grille.• Freeze-up protection and prevention.• PE treated condenser coil.

OPTIONS (factory mounted)

• Chilled water temperature down to- 5°C (OPZH) or -10°C (OPZL).

• High ESP fans (50Pa) (OPHF).• Pump size up (OPHP).

ACCESSORIES (kit)

• Refrigerant pressure gauges.• BMS gateway

(MODBUS/J-BUS/BACNET protocol).• Remote user interface.• 200l buffer tank.• Soft starter (single circuit).

CONTROL

• Microprocessor control.• Water inlet temperature control.

AVAILABLE INPUTS / OUTPUTS

Input• Remote ON/OFF.• Pump contact.Output• Compressor operation.• Pump relay contact.• Summary alarm.

Please note that Daikin also offers a 30 and 35hp-unit with cooling capacities of 68 and 79kW. For more information, please contact your local Daikin dealer.

EUWA*5KAZW EUWA*8KAZW EUWA*10KAZW EUWA*12KAZW

N P B N P B N P B N P B11.3 17.9 22.5 26.5

4.52 4.64 7.38 7.39 8.79 8.74 11.5 11.52.51 2.44 2.42 2.42 2.56 2.57 2.30 2.30

1,230x1,290x734 1,450x1,290x734150 168 180 215 229 241 245 259 271 248 262 274152 171 239 218 232 300 248 262 330 251 265 335

160 170 170 1702,900 2,900 2,900 2,90067 76 78 78

Hermetically sealed scroll0-100 0-100 0-100 0-100

11

R-407C400V/3N~/50Hz

5°C (-10°C as option) ~ 25°C-15°C ~ 43°C

Cross fin coil Hi-X tubes / PE coated waffle louvre finsBrazed plate heat exchanger

16 26 32 3832 51 64 7665 102 129 152

- 205 - 154 - 123 - 10524 38 43 3754 85 108 126

- 55 - 55 - 55 - 55- 12 - 12 - 12 - 12

1-1/4 1-1/4 1-1/4 1-1/4ø15 ø15 ø15 ø15

scroll

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 16

MOV99091_EPCEN07-400 Page 16 19-MAR-07

Cyan Magenta Yellow Black

Page 17: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

EUWAB12KAZW

17

Cooling capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgOperation weight kgNominal air flow rate m3/minFan speed rpmSound power level dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply W1Operation range water side °CDB

air side °CDBCondenser typeEvaporator type

HYDRAULICWater flow rate min. l/min

nominal l/minmax. l/min

Nominal static height unit kPaNominal pressure drop kPaMin. water volume in the system lBuffer tank volume lExpansion vessel volume lPiping connections water inlet/outlet "

water drain mm

EUWA*16KAZW EUWA*20KAZW EUWA*24KAZW

N P B N P B N P B37.0 46.6 55.3

15.2 15.0 18.1 17.9 24.0 24.02.42 2.47 2.57 2.60 2.30 2.30

1,321x2,580x734 1,541x2,580x734430 448 460 490 508 520 496 514 526436 457 525 496 518 586 503 524 592

2 x 170 2 x 170 2 x 1702,900 2,900 2,90079 81 81

Hermetically sealed scroll0-50-100

22

R-407C400V/3N~/50Hz

5°C (-10°C as option) ~ 25°C-15°C ~ 43°C

Cross fin coil Hi-X tubes / PE coated waffle louvre finsBrazed plate heat exchanger

52 67 79106 134 158212 267 317

- 187 - 137 - 10022 22 2288 111 132

- 55 - 55 - 55- 12 - 12 - 12

2 2 2ø15 ø15 ø15

AIR-COOLED (cooling only)

Air-cooled

EUWAN:standard equipment• Scroll compressor• Main isolator switch• Water flow switch• Filter• Condenser protection grille• All year operation

EUWAP = EUWAN +• Pump• Expansion vessel• Adjusting valve• Drain• Water pressure gauge• Pressure relief valve

EUWAB = EUWAP +• Buffer tank

Air purge

Buffer tank

Water Pressure gauge

Expansion vessel

Drain

Pressure port

Safety valve

Flow switch

Pump

Water flow adjustingvalve

Hydraulic and refrigerant diagram

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 17

MOV99091_EPCEN07-400 Page 17 19-MAR-07

Cyan Magenta Yellow Black

Page 18: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Nominal capacity cooling kWheating kW

Power input cooling kWheating kW

EERCOPDimensions (HxWxD) mmMachine weight kgOperation weight kgNominal air flow rate m3/minFan speed rpmSound power level dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply W1Operation range - water side cooling °CDB

heating °CDBOperation range - air side cooling °CDB

heating °CDBCondenser typeEvaporator type

HYDRAULICWater flow rate min. l/min

nominal - cooling l/minnominal - heating l/minmax. l/min

Nominal static height unit cooling kPaheating kPa

Nominal pressure drop cooling kPaheating kPa

Min. water volume in the system lBuffer tank volume lExpansion vessel volume lPiping connections water inlet/outlet "

water drain mm

18

EUWY*-KAZWAir-cooled

AIR-COOLED (heat pump) EUWY*5KAZW EUWY*8KAZW EUWY*10KAZW EUWY*12KAZW

N P B N P B N P B N P B9.1 17.1 21.0 25.011.9 18.5 24.0 27.0

3.78 3.78 7.45 7.46 8.57 8.57 11.4 11.44.59 4.59 7.10 7.10 9.10 9.10 10.8 10.8 10.82.40 2.40 2.30 2.30 2.45 2.45 2.20 2.20 2.202.60 2.60 2.60 2.60 2.64 2.64 2.50 2.50 2.50

1,230x1,290x734 1,450x1,290x734163 181 193 227 241 253 258 272 284 258 272 284165 184 252 230 244 312 261 275 343 261 275 343

160 170 170 1702,900 2,900 2,900 2,90067 76 78 78

Hermetically sealed scroll0-100 0-100 0-100 0-100

11

R-407C400V/3N~/50Hz

5°C (-10°C as option) ~ 25°C35°C ~ 50°C-15°C ~ 43°C-10°C ~ 21°C

Cross fin coil Hi-X tubes / PE coated waffle louvre finsBrazed plate heat exchanger

21 31 38 4526 49 60 7234 53 69 7768 106 137 155

- 223 - 171 - 151 - 118- 205 - 160 - 127 - 100

10 25 24 3317 29 31 3843 82 100 119

- 55 - 55 - 55 - 55- 12 - 12 - 12 - 12

1-1/4 1-1/4 1-1/4 1-1/4ø 15 ø 15 ø 15 ø 15

STRENGTHS

• Integrated hydraulic module(models B and P).

• Built-in buffer tank (model B).• Daikin scroll compressor.• Standard main isolator switch.• Standard water flow switch.• Standard filter (delivered as a kit

with the unit).• Operation down to -15°C ambient

temperature.• Standard reverse phase protection.• Standard condenser protection grille.• Freeze-up protection and prevention.• PE treated condenser coil.

OPTIONS (factory mounted)

• Chilled water temperature down to- 5°C (OPZH) or -10°C (OPZL).

• High ESP fans (50Pa) (OPHF).• Pump size up (OPHP).

ACCESSORIES (kit)

• Refrigerant pressure gauges.• BMS gateway

(MODBUS/J-BUS/BACNET protocol).• Remote user interface.• 200l buffer tank.• Soft starter (single circuit).

CONTROL

• microprocessor control.• Water inlet temperature control.

AVAILABLE INPUTS / OUTPUTS

Input• Remote ON/OFF.• Pump contact.• Remote cool/heat selection.Output• Compressor operation.• Summary alarm.• Pump relay contact.

scroll

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 18

MOV99091_EPCEN07-400 Page 18 19-MAR-07

Cyan Magenta Yellow Black

Page 19: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

EUWYB12KAZW

19

Air-cooled

Nominal capacity cooling kWheating kW

Power input cooling kWheating kW

EERCOPDimensions (HxWxD) mmMachine weight kgOperation weight kgNominal air flow rate m3/minFan speed rpmSound power level dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply W1Operation range water side °CDB

air side °CDBCondenser typeEvaporator type

HYDRAULICWater flow rate min. l/min

nominal - cooling l/minnominal - heating l/minmax. l/min

Nominal static height unit cooling kPaheating kPa

Nominal pressure drop cooling kPaheating kPa

Min. water volume in the system lBuffer tank volume lExpansion vessel volume lPiping connections water inlet/outlet "

drain mm

EUWY*16KAZW EUWY*20KAZW EUWY*24KAZW

N P B N P B N P B34.2 40.0 50.037.0 46.0 54.0

14.9 14.9 16.3 16.3 22.8 22.814.2 14.2 17.4 17.4 21.6 21.62.30 2.30 2.45 2.45 2.20 2.202.61 2.61 2.64 2.64 2.50 2.50

1,321x2,580x734 1,541x2,580x734455 473 485 516 534 546 516 534 546461 482 550 522 544 612 522 544 612

2 x 170 2 x 170 2 x 1702,900 2,900 2,90079 81 81

Hermetically sealed scroll0-50-100

22

R-407C400V/3N~/50Hz

5°C (-10°C as option) ~ 25°C-15°C ~ 43°C

Cross fin coil Hi-X tubes / PE coated waffle louvre finsBrazed plate heat exchanger

61 72 8998 115 143106 132 155212 263 309

- 209 - 183 - 146- 195 - 147 - 111

12 12 1914 16 2282 96 119

- 55 - 55 - 55- 12 - 12 - 12

2 2 2ø 15 ø 15 ø 15

AIR-COOLED (heat pump)

EUWYN:standard equipment• Scroll compressor• Main isolator switch• Water flow switch• Filter• Condenser protection grille.• All year operation

EUWYP = EUWYN +• Pump• Expansion vessel• Adjusting valve• Drain• Water pressure gauge• Pressure relief valve.

EUWYB = EUWYP +• Buffer tank

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 19

MOV99091_EPCEN07-400 Page 19 19-MAR-07

Cyan Magenta Yellow Black

Page 20: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Cooling capacity kWPower input kWEERDimensions HxWxD mmOperation weight kgNomimal air flow rate m3/hFan speed rpmSound power level (standard/low noise) dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply YNOperation range water side °C

air side °CCondenser typeEvaporator type

HYDRAULICNominal water flow rate l/minNominal static height - single pump kPaNominal static height - double pump kPaNominal pressure drop kPaMin. Water volume in the system lBuffer tank volume l

weight kgheight mm

Piping connections evaporator in/outletevaporator water drain

20

EWAP-CAYNAir-cooled

AIR-COOLED (cooling only)

STRENGTHS

• Integrated hydraulic module.• Standard main isolator switch.• Standard water flow switch.• Filter.• Operation down to -10°C ambient

temperature (-18°C with option inverterfans (OPIF)).

• Standard reverse phase protection.• Freeze-up protection and prevention.• Black epoxy treated condenser coil.

OPTIONS (factory mounted)

• Hydraulic module with single pump.• Hydraulic module with double pump.• Buffer tank up to 570l.• Low noise (-3 to -7dB(A)).• Double pump.• Single / Double pump contactors.• High ESP fans (60 to 80Pa).

• Ultra-low operation.outdoor temperature (-18°C).

• LON communication card.• Pressure gauges.• Condenser protection grilles.• Chilled water temperature down

to -4°C (OPZH) or -12°C (OPZL).

CONTROL

• Microprocessor control.• Water outlet temperature control.• Weekly operating schedule.• Water inlet temperature control.

AVAILABLE INPUTS / OUTPUTS

Input• ON / OFF (per circuit).• Dual setpoint.• Floating setpoint

(analog input 0 - 10V).Output• Compressor operation.• Summary alarm (per circuit).• Pump relay contact.

EWAP060CAYN EWAP080CAYN EWAP100CAYN EWAP120CAYN EWAP125CAYN EWAP130CAYN

62.5 76.2 101.9 121.8 129.7 128.924.4 28.8 36.4 43.6 50.5 49.12.56 2.65 2.80 2.79 2.57 2.63

1,897x2,800x1,100 1,897x3,200x1,100 2,092x3,200x1,100 1,897x3,400x2,300842 968 1,143 1,267 1,292 1,623

19,100 26,300 37,300 37,100 37,100 38,300700 700 680 680 680 700

85/80 86/81 86/85 90/88 91/88 88/83Hermetic scroll compressor

40-60 50 37-63 44-56 50 20-302 2 3 2 2 4

1 2R-407C

400V/3~50Hz-12°C ~ +12°C

-10°C (-18°C with option inverter fans) ~ 42°CSlit fin

Brazed plate heat exchanger

178.8 217.8 295.2 333 369 368.4180 174 139 201 186 207166 158 121 187 171 19133 38 46 43 44 30360 360 610 640 620 370370 410 410 410 410 570396 437 437 437 437 644

4002 2,5 2,5 2,5 2,5 2,5

Hose tube 15x21

scroll

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 20

MOV99091_EPCEN07-400 Page 20 19-MAR-07

Cyan Magenta Yellow Black

Page 21: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

21

Air-cooled

EWAP060CAYN

Cooling capacity kWPower input kWEERDimensions HxWxD mmOperation weight kgNomimal air flow rate m3/hFan speed rpmSound power level (standard/low noise) dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply YNOperation range water side °C

air side °CCondenser typeEvaporator type

HYDRAULICNominal water flow rate l/minNominal static height - single pump kPaNominal static height - double pump kPaNominal pressure drop kPaMin. Water volume in the system lBuffer tank volume l

weight kgheight mm

Piping connections evaporator in/outletevaporator water drain

EWAP160CAYN EWAP180CAYN EWAP210CAYN EWAP240CAY EWAP260CAY

157.1 182.8 214.2 241.3 261.857.9 68.4 77.9 88.3 102.42.71 2.67 2.75 2.73 2.56

2,100x3,400x2,3001,818 2,087 2,245 2,423 2,456

52,700 55,400 86,300 83,000 79,300700 700 680 680 680

89/84 89/85 95/89 95/89 95/91Hermetic scroll compressor

25 22-29 19-32 17-33 254 6 6 6 4

2R-407C

400V/3~50Hz-12°C ~ +12°C

-10°C (-18°C with option inverter fans) ~ 42°CSlit fin

Brazed plate heat exchanger

449.4 522.6 615 693 764.4186 197 174 137 125168 176 148 137 12436 30 35 38 41370 500 650 760 630570 570 570 570 570644 644 644 644 644

4002,5 3 3 3 3

Hose tube 15x21

AIR-COOLED (cooling only)

POSSIBLE CONFIGURATIONS

• Standard unit

• Unit with hydraulic module- Pump (single or double)- Expansion vessel- Adjusting valve- Drain- Water pressure gauge- Pressure relief valve- Filter

• Unit with hydraulic module& buffer tank

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 21

MOV99091_EPCEN07-400 Page 21 19-MAR-07

Cyan Magenta Yellow Black

Page 22: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

EWYP-CAYNAir-cooled

STRENGTHS

• Integrated hydraulic module.• Built-in buffer tank.• Standard main isolator switch.• Standard water flow switch.• Filter.• Operation down to -10°C ambient

temperature.• Standard reverse phase protection.• Freeze-up protection and prevention.• Black epoxy treated condenser coil.

OPTIONS (factory mounted)

• Hydraulic module with single pump.• Hydraulic module with double pump.• Buffer tank up to 570l.• Low noise (-3 to -7dB(A)).

• Double pump.• Single / Double pump contactors.• High ESP fans (60 to 80Pa).• LON communication card.• Pressure gauges.• Condenser protection grilles.• Chilled water temperature down

to -4°C (OPZH) or -12°C (OPZL).

CONTROL

• Microprocessor control.• Water output temperature control.• Weekly operating schedule.

AVAILABLE INPUTS / OUTPUTS

Input• ON / OFF (per circuit).• Dual setpoint.• Heat/Cool Switch.• Floating setpoint.

(analog input 0 - 10V).Output• Compressor operation.• Summary alarm (per circuit).• Pump relay contact.

Nominal capacity cooling kWheating kW

Nominal input cooling kWheating kW

EERCOPDimensions HxWxD mmOperation weight kgNomimal air flow rate m3/hFan speed rpmSound power level (standard/low noise) dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply YNOperation range - water side cooling °C

heating °COperation range - air side cooling °C

heating °CCondenser typeEvaporator type

HYDRAULICNominal water flow rate l/minNominal static height - single pump cooling kPa

heating kPaNominal static height - double pump cooling kPa

heating kPaNominal pressure drop cooling kPa

heating kPaMin. Water volume in the system lBuffer tank volume l

weight kgheight mm

Piping connections evaporator in/outletevaporator water drain

22 AIR-COOLED (heat pump) EWYP060CAYN EWYP075CAYN EWYP095CAYN EWYP110CAYN EWYP120CAYN EWYP130CAYN

60.8 73.6 93.6 116 122 12659.6 72.7 99.2 112 120 11925.4 30.1 37.6 42.8 49.7 51.124.9 30.4 43 45.7 48.6 49.52.39 2.45 2.49 2.71 2.45 2.472.39 2.39 2.31 2.45 2.47 2.40

1,897x2,800x1,100 1,897x3,200x1,100 2,092x3,200x1,100 1,897x3,400x2,300870 996 1,182 1,302 1,331 1,677

19,100 26,300 37,300 37,100 37,100 38,300700 700 680 680 680 700

85/80 86/81 86/85 90/88 91/88 88/83Hermetic scroll compressor

40-60 50 37-63 44-56 50 20-302 2 3 2 2 4

1 2R-407C

400V/3~50Hz-12°C ~ +12°C25°C ~ 50°C-10°C ~ 42°C

-10°C ~ +20°CAluminium fins with black epoxy coating

Brazed plate heat exchanger

178.8 217.8 295.2 333 369 3682180 174 139 201 186 207180 174 139 201 186 207166 158 121 187 171 191166 158 121 187 171 19131 35 39 40 39 2831 35 39 40 39 28360 360 610 640 620 370370 410 410 410 410 570396 437 437 437 437 644

4002 2,5 2,5 2,5 2,5 2,5

Hose tube 15x21

scroll

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 22

MOV99091_EPCEN07-400 Page 22 19-MAR-07

Cyan Magenta Yellow Black

Page 23: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

EWYP060CAYN

23EWYP150CAYN EWYP170CAYN EWYP200CAYN EWYP220CAYN EWYP250CAYN

153 167 195 229 247145 172 198 228 24760.7 69.8 78.2 91.6 10260.4 69.6 84.5 86.5 1012.52 2.39 2.49 2.50 2.422.40 2.47 2.34 2.64 2.45

2,100x3,400x2,3001,872 2,166 2,324 2,502 2,53552,700 55,400 86,300 83,000 79,300700 700 680 680 680

89/84 89/85 95/89 95/89 95/91Hermetic scroll compressor

25 22-29 19-32 17-33 254 6 6 6 4

2R-407C

400V/3~50Hz-12°C ~ +12°C25°C ~ 50°C-10°C ~ 42°C

-10°C ~ +20°CAluminium fins with black epoxy coating

Brazed plate heat exchanger

449.4 522.6 615 693 764.4186 197 174 133 125186 197 174 133 125168 176 148 134 124168 176 148 134 12435 25 29 32 3635 25 29 32 36370 500 650 760 630570 570 570 570 570644 644 644 644 644

4002,5 3 3 3 3

Hose tube 15x21

Nominal capacity cooling kWheating kW

Nominal input cooling kWheating kW

EERCOPDimensions HxWxD mmOperation weight kgNomimal air flow rate m3/hFan speed rpmSound power level (standard/low noise) dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply YNOperation range - water side cooling °C

heating °COperation range - air side cooling °C

heating °CCondenser typeEvaporator type

HYDRAULICNominal water flow rate l/minNominal static height - single pump cooling kPa

heating kPaNominal static height - double pump cooling kPa

heating kPaNominal pressure drop cooling kPa

heating kPaMin. Water volume in the system lBuffer tank volume l

weight kgheight mm

Piping connections evaporator in/outletevaporator water drain

AIR-COOLED (heat pump)

POSSIBLE CONFIGURATIONS

Standard unit

Unit with hydraulic module• Pump (single or double)• Expansion vessel• Adjusting valve• Drain• Water pressure gauge• Pressure relief valve• Filter

Unit with hydraulic module& buffer tank

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 23

MOV99091_EPCEN07-400 Page 23 19-MAR-07

Cyan Magenta Yellow Black

Page 24: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Cooling capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgOperation weight kgNominal air flow rate m3/minFan speed rpmSound power level (standard / low noise option) dBaCompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply YNOperation range air side °CDB

water side °CDBCondenser typeEvaporator typeWater flow rate min. l/min

max. l/minNominal water presure drop kPaMin. Water volume in the system lPiping connections evaporator in/outlet

evaporator water drain

24

EWAD-MBYNAir-cooled

EWAD170MBYN

AIR-COOLED (cooling only)

STRENGTHS

• DAIKIN stepless single screw compressor.• Operation down to -15°C ambient

temperature.• Standard reverse phase protection.• Freeze-up protection and prevention.• PE treated condenser coil.• VICTAULIC joints.• Standard discharge shut-off valve.• DICN operation as standard within

same series.• Flow switch.• Modular design.• High energy efficiency ratio.

OPTIONS (factory mounted)

• Main isolator switch.• Condenser protection grilles.• Low noise (-5 to -7dB(A)).• Compressor suction stop valve.• Ampere & Voltmeter

(read-out on switchbox).

• Chilled water temperature down to- 5°C (ZH) or -10°C (ZL).

• Hi-ESP fans.• Dual pressure relief valve.

ACCESSORIES (kit)

• Leaving water control sensor for DICN.• BMS gateway.

(MODBUS/J-BUS/BACNET protocol).• Remote user interface (EKRUPC).

CONTROL

• Microprocessor control.• Water inlet or outlet temperature control.• Leaving water control sensor for DICN.

AVAILABLE INPUTS / OUTPUTS

Input• ON / OFF (per circuit).• Dual setpoint.• Pump / flow switch.Output• Compressor operation.• Summary alarm (per circuit).• Pump relay contact.

EWAD120MBYN EWAD150MBYN EWAD170MBYN EWAD240MBYN EWAD300MBYN EWAD340MBYN

121 149 171 226 286 33041.1 54.1 64.9 83.7 105 1362.94 2.75 2.63 2.70 2.72 2.43

2,221x3,973x1,109 2,221x3,973x1,109 2,221x3,973x1,109 2,250x4,280x2,238 2,250x4,280x2,238 2,250x4,280x2,2381,391 1,600 1,705 2,710 3,210 3,2601,441 1,663 1,768 2,790 3,340 3,390960 960 960 1,920 1,920 1,920730 900 900 730 900 900

87/84 94/88 92/85 90/87 97/91 95/88Semi-hermetic single screw compressor

30%-100% stepless 15%-100% stepless1 1 1 2 2 21 1 1 2 2 2

R-134a400V/3~/50Hz-15°C ~ 43°C

4°C (-10°C as option) ~26°CCross fin coil / Hi-X tubes and Polyethylene coated waffle louvre fins

Shell and tube150 200 200 300 395 395490 725 725 930 1165 116531.7 18.6 24.8 41.0 36.6 49.1590 730 840 550 700 810

3" victaulic coupling 4" victaulic coupling 5" victaulic coupling1/2" G-F UNI-ISO 228/1

screw

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 24

MOV99091_EPCEN07-400 Page 24 19-MAR-07

Cyan Magenta Yellow Black

Page 25: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Cooling capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgOperation weight kgNominal air flow rate m3/minFan speed rpmSound power level (standard/low noise option) dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply YNOperation range air side °CDB

water side °CDBCondenser typeEvaporator typeWater flow rate min. l/min

max. l/minNominal water pressure drop kPaMin. water volume in the system l/minPiping connections evaporator water in/outlet

evaporator water drain

EWAP110MBYN EWAP140MBYN EWAP160MBYN EWAP200MBYN EWAP280MBYN EWAP340MBYN EWAP400MBYN EWAP460MBYN EWAP540MBYN

111 144 164 199 285 349 395 468 54141.9 51.8 64.3 78.1 108 140 156 189 2222.65 2.78 2.55 2.55 2.64 2.49 2.53 2.48 2.44

2,250x2,346x2,238 2,250x4,280x2,238 2,250x5,901x2,2381,417 1,571 1,660 2,203 2,583 2,633 4,865 4,988 5,1111,425 1,584 1,676 2,223 2,610 2,667 4,939 5,069 5,199960 960 960 1,920 1,920 1,920 2,880 2,880 2,880730 900 900 730 900 900 900 900 900

89/86 94/89 94/88 95/93 96/90 98/92 99/93 99/94 99/94Semi-hermetic single screw stepless compressor

30-100 15-1001 21 2

R-407C400V/3~/50Hz-10°C ~ 26°C-15°C ~ 43°C

Cross fin coil / Hi-X tubes and polyethylene coated waffle louvre finsBrazed plate heat exchanger

160 205 235 285 410 500 565 670 775640 825 940 1,140 1,640 2,000 2,265 2,680 3,10050 48 41 31 42 52 35 39 44540 700 800 970 1,390 1,710 970 1,140 1,320

Flexible coupling + counterpipe for welding 3" OD Flexible coupling + counterpipe for welding 3" Flexible coupling + counterpipe for welding 5"Compressor: 1"NPT Compressor: Compressor: Compressor: 1x(1"NPT) Compressor:

2x1"NPT 2x (1"NPT) +1x(2x1"NPT) 2x(2x1"NPT)

25AIR-COOLED (cooling only)

EWAP-MBYNAir-cooled

EWAP200MBYN

STRENGTHS

• DAIKIN stepless single screwcompressor.

• Operation down to -15°C ambienttemperature.

• Standard reverse phase protection.• Freeze-up protection and prevention.• PE treated condenser coil.• VICTAULIC joints and filter as standard.• DICN operation as standard within

same series.• Chilled water temperature down to

- 5°C(ZH) or -10°C(ZL) (user setting).• Standard discharge shut-off valve.• Standard flow switch.• Modular design.

OPTIONS (factory mounted)

• dual pressure relief valve on thecondenser.

• Main isolator switch.• Condenser protection grilles.• Low noise (-5 to -7dB(A)).• Compressor suction stop valve.• Ampere & Voltmeter

(read-out on switchbox).• Hi-ESP fans.• Inverter fans.• Heat Recovery (see also page 26).

ACCESSORIES (kit)

• leaving water control sensor for DICN.• BMS card.• BMS gateway

(MODBUS/J-BUS/BACNET protocol).• Remote user interface (EKPUPC).

CONTROL

• Microprocessor control.• Water inlet or outlet temperature control.• Weekly operating schedule.

AVAILABLE INPUTS / OUTPUTS

Input• ON / OFF (per circuit).• Dual setpoint through analog signal.• Floating setpoint.• Pump / flow switch.Output• Compressor operation.• Summary alarm (per circuit).• Pump relay contact.

screw

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 25

MOV99091_EPCEN07-400 Page 25 19-MAR-07

Cyan Magenta Yellow Black

Page 26: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

EWTP-MBYNAir-cooled

EWTP-MBYN

(Based on EWAP-MBYN)

In many applications there often exists asimultaneous cooling and heating demandrequirement alongside one another. Tobenefit from this Daikin offer the full rangeof R-407C EWTP110-540MBYN chillerswith heat recovery. This option furtherincreases the application flexibility andextends possibilities in the hotel and leisureindustry as well as the industrial and processsectors.

By energetically recovering useful heat fromthe cooling cycle that would otherwise berejected to outside COPs of up to 5.62 canbe realized in heat recovery mode. The heatrecovery unit aims to achieve an optimumbalance between cooling and heat recoveryto maximize the unit efficiency and offersavings in hot water production.

For full heat recovery both sensible andlatent heat exchange will occur in therecovery exchanger. Inverter fans will beused to control the recovery outletwater temperature, by throttling backthe airflow and maintaining the requiredcondensing temperature.

As a desuperheater the sensible heat fromthe hot discharge gas will be recovered,while the latent heat exchange will occurin the air-cooled condenser. The units effi-ciency is maintained as condensing pres-sure can be reduced due to air-cooled con-denser becoming oversized. Hot watertemperatures up to 70°C can be achieved.

Nominal capacity cooling kWcooling during heat recovery kWheat recovery kW

Nominal input cooling kWheat recovery mode kW

Heat recovered %Dimensions HxWxD mmMachine weight kgOperation weight kgNominal air flow rate m3/minFan speed rpmSound power level standard / low noise dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply YNOperation range air side °CDB

water side °CDBCondenser typeHeat recovery condenser typeEvaporator typeWater flow rate min. l/min

max. l/minNominal water pressure drop kPaMin. water volume in the system lPiping connections evaporator water inlet/outlet

heat recovery condenser inlet/outletevaporator water drain

EWTP110MBYN EWTP140MBYN EWTP160MBYN EWTP200MBYN EWTP280MBYN EWTP340MBN EWTP400MBYN EWTP460MBYN EWTP540MBYN

107 138 158 191 274 335 379 449 52097.7 126 144 171 251 311 337 401 465116 148 176 208 301 377 407 434 44143.7 54 67 81.3 113 146 163 197 23239.4 47.8 62.4 73.2 103 132 142 177 21485 85 85 85 85 85 85 75 65

2,250x2,346x2,238 2,250x4,280x2,238 2,250x5,901x2,2381,465 1,629 1,723 2,266 2,646 2,727 4,990 5,113 5,2361,483 1,654 1,752 2,299 2,692 2,784 5,090 5,220 5,350960 960 960 1,920 1,920 1,920 2,880 2,880 2,880730 900 900 730 900 900 900 900 900

89/86 94/89 94/88 95/93 96/90 98/92 99/93 99/94 99/94Semi-hermetic single screw compressor

30-100% stepless 15-100% stepless1 1 1 1 1 1 2 2 21 1 1 1 1 1 2 2 2

R-407C400V/3~/50Hz-10°C ~ 26°C-15°C ~ 43°C

Cross fin coil / Hi-X tubes and chromate waffle louvre finsBrased plate heat exchanger, one per circuitBrased plate heat exchanger, one per circuit

160 205 235 285 410 500 565 670 775640 825 940 1,140 1,640 2,000 2,265 2,680 3,10044 41 33 25 29 32 29 32 36520 680 770 930 1,340 1,640 930 1,100 1,270

Flexible coupling + counterpipe for welding 3" OD Flexible coupling + counterpipe for welding 3" "Flexible coupling 5"2"G

field installation 1/4"G

AIR-COOLED (heat recovery)26

7°C 12°C

Partial Recovery(Desuperheater)

Condenser

60°C

50°C

35% of CC + PI

Comp

7°C 12°C

Full Recovery

Condenser

45°C

40°C

85% of CC + PI

Comp

screw

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 26

MOV99091_EPCEN07-400 Page 26 19-MAR-07

Cyan Magenta Yellow Black

Page 27: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Cooling capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgOperation weight kgNominal air flow rate m3/secFan driveExternal static pressure nom. Pa

max. PaSound power level dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply W1Operation range water side °CDB

air side °CDBCondenser typeEvaporator typeWater flow rate min. l/min

max. l/minNominal pressure drop kPaMin. water volume in the system lPiping connections evaporator in/outlet "

27

EUWAC-FZWAir-cooled

EUWAC8FZW

AIR-COOLED (cooling only) EUWAC5FZW EUWAC8FZW EUWAC10FZW

11.6 18.4 23.85.25 7.78 9.852.21 2.37 2.42

1,345x856x630 1,290x1,180x630 1,395x1,330x630164 224 261166 228 2661.17 1.83 2.10

direct drive belt drive50 60 72100 15063 66 69

Hermetically sealed scroll compressor100-0

11

R-407C400V/3N~/50Hz

4°C (-10°C as option) ~ 21°C-10°C ~ 43°C

Cross fin coil / Hi-X tubes and chromate coated waffle louvre finsBrazed plate heat exchanger

16 23 2864 92 11226 42 48101 153 2121 1 1

STRENGTHS

• Daikin scroll compressor.• Standard reverse phase protection.• High static pressure (up to 150Pa).• Operation down to -10°C ambient

temperature.• Pressure gauges.

OPTIONS (factory mounted)

• Chilled water temperature down to- 5°C (ZH) or -10°C (ZL).

ACCESSORIES (kit)

• Filter.• BMS gateway

(MODBUS / J-BUS / BACNET protocol).• Remote user interface.• Hydraulic module (see page 28).

CONTROL

• Microprocessor control.• Water inlet temperature control.

AVAILABLE INPUTS / OUTPUTS

Input• ON / OFF (per circuit).• Pump / flow switch.Output• Compressor operation.• Summary alarm.• Pump relay contact.

scroll

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 27

MOV99091_EPCEN07-400 Page 27 19-MAR-07

Cyan Magenta Yellow Black

Page 28: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Nominal flow l/minNominal static height mH2OTank volume lNumber of pumpsExpansion vessel volume lFilter assemblyDimensions (HxWxD) mmMachine weight kgOperation weight kgSound power level dBAPower supply V1Operation range water side °CDB

air side °CDBPiping connections

HYDRAULIC MODULE

EHMC-AVHydraulic module

EHMC15AV1010

EHMC10AV EHMC15AV EHMC30AV

1010 1080 1010 1080 1010 108062 88 187

17 34 15 27 10 27100 100 1001 1 112 12 12

1" + 3/4" 2" 2 1/2" + 2"1,284x635x688 1,284x635x688 1,284x635x688

99 101 102 104 105 111199 201 202 204 205 21163 63 63 63 63 63

230V/1~/50Hz 230V/1~/50Hz 230V/1~/50Hz-10°C ~ 55°C -10°C ~ 55°C -10°C ~ 55°C-10°C ~ 43°C -10°C ~ 43°C -10°C ~ 43°C

1" BSP F galvanised steel 2" BSP F galvanised steel 2 1/2" BSP F galvanised steel

3

4

1

2

56

mH20

55

50

45

40

35

30

25

20

15

10

5

00 20 40 60 80 100 120 140 160 180 200 220 240 260

WF (l/min)

STRENGTHS

• 100l buffer tank.• Freeze-up protection (heater tape).• Single pump.• 12l expansion vessel.• Standard dual pressure ports.

LEGENDS

Pump characteristics1 - EHMC30AV10802 - EHMC10AV1080 & EHMC15AV10803 - EHMC30AV10104 - EHMC10AV1010 & EHMC15AV1010Hydraulic module + filter pressures losses5 - EHMC15/30AV1010 & EHMC15/30AV10806 - EHMC10AV1010 & EHMC10AV1080Water flow

PUMP CHARACTERISTICS

28

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 28

MOV99091_EPCEN07-400 Page 28 19-MAR-07

Cyan Magenta Yellow Black

Page 29: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Tank volume lMaterial / insulationSafety valve barDrain/fill valveAutomatic airpurgeDimensions (HxWxD) mmMachine weight kgOperation weight kgOperation range water side °C

air side °CPower supplyPower input WRated current A

BUFFER TANK EKBT

200Steel St37.2 / Trocellen-Al 10 mm

1 x 6.011

1,284x637x75486.5286.5

-10°C to 55°C-15°C to 43°C

230V/1~2000.9

EKBTBuffer tank

29

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 29

MOV99091_EPCEN07-400 Page 29 19-MAR-07

Cyan Magenta Yellow Black

Page 30: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

30

TABLE OF CONTENTS31 ERAP-MBYN cooling only from 114 to 171kW

The Daikin ERAP condensing units can be used in a wide

variety of air conditioning, refrigeration and ventilation

applications. The ERAP operates with refrigerant R-407C, and

can be connected to 3rd party manufactured evaporators, e.g.

used in air handling units.

Remote evaporator

PIPING DIAGRAM FOR COMFORT COOLING APPLICATION

1 Switchbox

2 Thermistor line

1 2

Chiller Air handling unit

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 30

MOV99091_EPCEN07-400 Page 30 19-MAR-07

Cyan Magenta Yellow Black

Page 31: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

ERAP150MBYN

ACCESSORIES (kit)

• BMS gateway(MODBUS/J-BUS/BACNET protocol).

• Remote user interface.

CONTROL

• Return air or room temperaturecontrol.

• Weekly operating schedule.

AVAILABLE INPUTS / OUTPUTS

Input• ON / OFF.• Dual setpoint through analog signal.• Air flow switch.• Capacity limit.Output• Compressor operation.• Summary alarm.

31Remote evaporator

ERAP-MBYNRemote evaporator

STRENGTHS

• DAIKIN stepless single screw compressor.• Operation down to -15°C ambient

temperature.• Standard reverse phase protection.• Freeze-up protection and prevention.• PE treated condenser coil.• Liquid stop valve.• Discharge stop valve.• Standard suction stop valve.

OPTIONS (factory mounted)

• Main isolator switch.• Condenser protection grilles.• Low noise (down to -6dB(A)).• Ampere & Voltmeter

(read-out on switchbox).• Hi-ESP fans.

Cooling capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgNominal air flow rate m3/minFan speed rpmSound power level standard / low noise option dBACompressor typeCapacity steps %Number of compressorsNumber of refrigerant circuitsRefrigerant typePower supply Y1Operation range evaporating temp. °CDB

air side °CDBCondenser typePiping connections condenser outlet

compressor suction inlet

REMOTE EVAPORATOR (cooling only) ERAP110MBYN ERAP150MBYN ERAP170MBYN

114 150 17142.1 52.4 65.22.71 2.86 2.62

2,250 x 2,346 x 2,2381,326 1,440 1,516

960730 900 900

91/88 96/91 96/90Stepless semi-hermetic single screw

30 to 100% stepless11

R-407C400V/3~/50Hz-15°C ~ 18°C-15 C ~ 43°C

Cross fin coil / Hi-X tubes and chromate coated waffle louvre fins7/8"

2 1/8"

screw

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 31

MOV99091_EPCEN07-400 Page 31 19-MAR-07

Cyan Magenta Yellow Black

Page 32: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

32

34 EWLP-KAW1 cooling only from 12 to 62kW 35 EWLD-MBYN cooling only from 116 to 530kW

Daikin offers you flexible and compact chillers with remote

condenser, which can be used to satisfy applications with

special requirements in the field of available space, sound

level or extreme operating conditions. In these exceptional

cases, remote condenser solutions can be preferred over

standard air-cooled or water-cooled solutions.

Remote condenser

TABLE OF CONTENTS

ToCondenser

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 32

MOV99091_EPCEN07-400 Page 32 19-MAR-07

Cyan Magenta Yellow Black

Page 33: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

33

7 6 5 4 5 3 2 1

5 98 10 11

12

7

1

Remote condenser

1 Temperature sensor

2 Filter

3 Shut-off valve

4 Pump

5 Pressure port

6 Flow switch

7 Drain

8 Pressure gauge

9 Water flow adjusting valve

10 Drain valve

11 Fill valve

12 Safety valve

TECHNOLOGY SUPPORTING THE ENVIRONMENT

SINGLE SCREW STEPLESSCOMPRESSORSDeveloped and manufac-tured by DAIKIN, the DAIKINsingle screw compressor isappreciated for its reliability.Single screw compressorsare used with remote con-denser chillers within therange of capacities between100 and 580KW

SCROLL COMPRESSORSBeing compact, the DAIKINscroll compressor is usedwith R-407C. Designedfor small and mediumcapacities, Scroll compres-sors are used with separatecondenser chillers withinthe range of capacitiesbetween 12 and 62kW.

Showing respect for theenvironment, R-407C is anHFC, which is used forremote condenser chillerswithin a capacity range ofbetween 12 and 62kW.

Valued for the energyefficiencies that it helpsattain, R-134a is a pure HFC.It is used for remotecondenser chillers within acapacity range of between116 and 530kW.

The only manufacturer to develop both the air conditioning equipment and refrigerants, DAIKIN boasts aninternational reputation in terms of technological innovation.

Chillers

Tofan coil

units

EV

AP

OR

AT

OR

Expan-sion

vessel

Buffertank

ToCondenser

Gas

Liquid

PIPING DIAGRAM FOR COMFORT COOLING APPLICATION

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 33

MOV99091_EPCEN07-400 Page 33 19-MAR-07

Cyan Magenta Yellow Black

Page 34: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

STRENGTHS

• One of the most compact units in themarket (60cm x 60cm x 60cm formodels 012 to 030).

• Daikin scroll compressor.• Standard main isolator switch.• Basic hydraulic components : included

as a kit with the unit: flow switch, airpurge, filter + shut-off valves.

• Standard reverse phase protection.

OPTIONS (factory mounted)

• Chilled water temperature down to- 5°C (ZH) or -10°C (ZL).

ACCESSORIES (kit)

• Compressor soundproof material(-3dBA).

• Hydraulic module (see page 28).• BMS gateway (MODBUS/J-BUS /

BACNET protocol).• Remote user interface.

CONTROL

• Microprocessor control.• Water inlet temperature control.

AVAILABLE INPUTS/OUTPUTS

Input• Remote ON / OFF.• Pump contact.Output• Compressor operation.• Summary alarm.• Pump relay contact.

Nominal capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgSound power level dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply W1Operation range - water side °CDBOperation range - condensing temperature °CEvaporator typeWater flow rate min. l/min

nominal l/minmax. l/min

Min. water volume in the system lPiping connections evaporator water inlet/outlet mm

discharge connection - flare mmliquid connection - flare mm

EWLP012KAW1 EWLP020KAW1 EWLP026KAW1 EWLP030KAW1 EWLP040KAW1 EWLP055KAW1 EWLP065KAW1

12.1 20.0 26.8 31.2 40.0 53.7 62.44.2 6.6 8.5 10.1 13.4 17.8 20.32.88 2.98 3.08 3.06 2.96 2.98 3.04

600x600x600 600x600x1,200108 141 147 151 252 265 27464 64 64 71 67 67 74

Hermetically sealed scroll1 21 21 2

R-407C400V/3N~/50Hz

5°C (-10°C as option) ~ 20°C25°C ~ 60°C

Brazed plate heat exchanger17 29 38 45 57 77 8935 57 77 89 115 154 17969 115 153 179 229 307 35862 103 134 155 205 268 311

FBSP25 FBSP4012.7 19.1 19.1 19.1 2 x 19.1 2 x 19.1 2 x 19.19.52 12.7 12.7 12.7 2 x 12.7 2 x 12.7 2 x 12.7

34

EWLP-KAW1Remote condenser

REMOTE CONDENSER (cooling only)

EWLP012KAW

60 60

60

scroll

EPCEN07-400:EPCEN07-400 12/03/07 15:15 Page 34

MOV99091_EPCEN07-400 Page 34 19-MAR-07

Cyan Magenta Yellow Black

Page 35: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

STRENGTHS

• DAIKIN stepless single screw compressor.• Compact and modular design.• Standard phase sequence controller.• VICTAULIC joints.• DICN operation as standard within

same series.• Standard discharge shut-off valve.• Standard flow switch.• Standard filter.

OPTIONS (factory mounted)

• Main isolator switch.• Low noise (-6dB(A)).• Compressor suction stop valve.• Ampere and Voltmeter (read-out

on switchbox).

• Chilled water temperature down to- 5°C (ZH) or -10°C (ZL).

• Dual pressure relief valve.

ACCESSORIES (kit)

• BMS gateway (MODBUS/J-BUS /BACNET protocol).

• Remote user interface.

CONTROL

• Microprocessor control.• Water inlet or outlet temperature

control.• Weekly operating schedule.

AVAILABLE INPUTS/OUTPUTS

Input• ON / OFF.• Pump contact.• Dual setpoint through analog signal.• Floating set point.Output• Compressor operation.• Summary alarm.• Fan-condenser relay contacts.• Pump relay contact.

Cooling capacity kWPower input kWEERDimensions (HxWxD) mmMachine weight kgOperation weight kgSound power level (standard/low noise option) dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply Y1Operation range water side °C

condensing temp. °CEvaporator typeWater flow rate min. l/min

max. l/minMin. water volume in the system lPiping connections type

evaporator water inlet/outlet

EWLD120MBYN EWLD170MBYN EWLD240MBYN EWLD260MBYN EWLD340MBYN EWLD400MBYN EWLD480MBYN EWLD500MBYN EWLD540MBYN

116 170 235 265 340 405 470 500 53032.0 49.8 66.5 77.9 99.6 116 133 144 1563.63 3.41 3.53 3.40 3.41 3.49 3.53 3.47 3.40

1,018x2,681x930 2,000x2,681x930891 1,110 1,342 1,428 2,220 2,452 2,684 2,770 2,856907 1,130 1,369 1,462 2,260 2,497 2,738 2,831 2,92487/81 93/87 94/88 93/87 96/90 96/90 96/90 96/90 96/90

Single screw stepless compressor30-100% stepless 5-100% stepless

1 1 1 1 2 2 2 2 21 1 1 1 2 2 2 2 2

R-134a400V/3~/50Hz-10°C ~ 20°C25°C ~ 55°C

Brazed plate heat exchanger175 265 350 400 525 625 700 750 800700 1,070 1,400 1,600 2,100 2,500 2,800 3,000 3,200570 830 1,150 1,300 830 990 1,150 1,220 1,295

Victaulic3"OD 3"

35REMOTE CONDENSER (cooling only)

EWLD120MBYN

EWLD-MBYNRemote condenser

screw

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 35

MOV99091_EPCEN07-400 Page 35 19-MAR-07

Cyan Magenta Yellow Black

Page 36: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

36

38 EWWP-KAW1 cooling only/ from 13 to 195kWheating only

40 EWWD-MBYN cooling only/ from 123 to 571kWheating only

Daikin offers you compact water-cooled chiller units which

require only very limited space in a machine room. Used for

commercial or industrial applications, these chillers generate

cold and hot water, which can be used for chilling, heating,

or even both at the same time.

Water-cooled

TABLE OF CONTENTS

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 36

MOV99091_EPCEN07-400 Page 36 19-MAR-07

Cyan Magenta Yellow Black

Page 37: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

37

8911 101214132

5

6

5

7

5

8 9 10 1211 13 2 41 3

7

5

5

5

6

4 8

Water-cooledPIPING DIAGRAM FOR COMFORT COOLING APPLICATION

1 Balancing valve2 Pressure gauge3 Temperature sensor4 Drain valve5 Shut-off valve

6 Fill valve7 Filter8 Drain9 Safety valve10 Pressure port

11 Pump12 Flow switch13 Pressure regulating valve14 Bypass valve

TECHNOLOGY SUPPORTING THE ENVIRONMENT

STEPLESS SINGLE SCREWCOMPRESSORSDeveloped and manufac-tured by DAIKIN, the DAIKINsingle screw compressor isappreciated for its reliability.Single screw compressors areused with water-colled chillerswithin the range of capacitiesbetween 100 and 580 kW.

SCROLL COMPRESSORS

Being compact, the DAIKINscroll compressor is used withR-407C. Designed for smalland medium capacities, Scrollcompres-sors are used withseparate condenser chillerswithin the range of capacitiesbetween 12 and 62kW.

Showing respect for theenvironment, R-407C is anHFC, which is used for watercooled chillers within acapacity range of between13 and 195kW.

Valued for the energyefficiencies that it helpsattain, R-134a is a pure HFC.It is used for water cooledchillers within a capacityrange of between 123 and571kW.

The only manufacturer to develop both the air conditioning equipment and refrigerants, DAIKINboasts an international reputation in terms of technological innovation.

Chillers

EV

AP

OR

AT

OR

Expan-sion

vessel

Buffertank

To fan coilunits

To fan coilunits

CO

ND

EN

SER

Expan-sion

vessel

Buffertank

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 37

MOV99091_EPCEN07-400 Page 37 19-MAR-07

Cyan Magenta Yellow Black

Page 38: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Nominal capacity cooling kWheating (40°-45°C) kW

Power input cooling kWheating (40°-45°C) kW

EERCOPDimensions (HxWxD) mmMachine weight kgSound power level dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply W1Operation range - evaporator °COperation range - condenser °CCondenser typeEvaporator typeWater flow rate - evaporator min. l/min

nominal l/minmax. l/min

Min. water volume in the system lWater flow rate - condenser min. l/min

nominal l/minmax. l/min

Piping connections evaporator water inlet/outlet mmcondenser water inlet/outlet mm

38 WATER-COOLED (cooling/heating only)

EWWP-KAW1Water-cooled

EWWP014KAW1 EWWP022KAW1 EWWP028KAW1 EWWP035KAW1 EWWP045KAW1 EWWP055KAW1 EWWP065KAW1

13.0 21.5 28.0 32.5 43.0 56.0 65.015.4 25.2 34.2 39 50.1 67.2 77.43.61 5.79 7.48 8.75 11.8 15.5 17.64.47 7.16 9.52 11.19 14.5 19.5 22.53.50 3.61 3.61 3.57 3.55 3.5 3.553.42 3.55 3.64 3.51 3.43 3.48 3.50

600x600x600 600x600x1,200113 150 160 167 300 320 33464 64 64 71 67 67 74

Hermetically sealed scroll1 21 21 2

R-407C400V/3N~/50Hz

5°C (-10°C as option) ~ 20°C20°C ~ 55°C

Brazed plate heat exchangerBrazed plate heat exchanger

19 31 40 47 62 80 9337 62 80 93 123 161 18675 123 161 186 247 321 37362 103 134 155 205 268 31124 39 51 59 79 102 11848 78 102 118 157 205 23795 157 203 237 314 410 474

FBSP25 FBSP40FBSP25 FBSP40

STRENGTHS

• One of the most compact units in themarket (60cm x 60cm x 60cm formodels 014 to 035).

• Daikin scroll compressor.• Standard reverse phase protection.• Extension possible up to 195kW.

For single module units

• Standard main isolator switch.• Basic hydraulic components for KA-series

included with the unit as a kit: flowswitch, air purge, filter + shut-off valvesfor both condenser and evaporator.

OPTIONS (factory mounted)

• Chilled water temperature down to- 5°C (OPZH) or -10°C (OPZL).

ACCESSORIES (kit)

• Compressor soundproof material (-3dBA).• Hydraulic module (see page 28).• BMS gateway (MODBUS/J-BUS /

BACNET protocol).• Remote user interface.

CONTROL

• Microprocessor control.• Water inlet temperature control.• Cold water or hot water regulation.

AVAILABLE INPUTS/OUTPUTS

InputRemote ON/OFF.Pump contact.Cool/heat selection.OutputCompressor operation.Summary alarm.Pump relay contact.

scroll

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 38

MOV99091_EPCEN07-400 Page 38 19-MAR-07

Cyan Magenta Yellow Black

Page 39: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Capacity indexCooling capacity (kW)Heating capacity (kW)

EWWP014KAW1NEWWP022KAW1NEWWP028KAW1NEWWP035KAW1NEWWP045KAW1NEWWP055KAW1NEWWP065KAW1N

EWWP045KAW1MEWWP055KAW1MEWWP065KAW1M

ECB 1 MUWECB 2 MUWECB 3 MUW

39SELECTION TABLE

EWWP014-035KAW1

UNIT+

CONTROL(factory mounted)

UNIT ONLY(Without Control)

CONTROL(Kit)

014 022 028 035 045 055 065 090 100 110 120 130 145 155 165 175 185 19513 21,5 28 32,5 43 56 65 86 99 112 121 130 142 155 168 177 186 19516 26.2 35.3 41 52.5 71 81 105 124 142 153 164 176 195 213 224 235 246

1 - - - - - - - - - - - - - - - - -- 1 - - - - - - - - - - - - - - - -- - 1 - - - - - - - - - - - - - - -- - - 1 - - - - - - - - - - - - - -- - - - 1 - - - - - - - - - - - - -- - - - - 1 - - - - - - - - - - - -- - - - - - 1 - - - - - - - - - - -

- - - - 1 - - 2 1 - - - 2 1 - - - -- - - - - 1 - - 1 2 1 - 1 2 3 2 1 -- - - - - - 1 - - - 1 2 - - - 1 2 3- - - - 1 1 1 - - - - - - - - - - -- - - - - - - 1 1 1 1 1 - - - - - -- - - - - - - - - - - - 1 1 1 1 1 1

For example: for a 121 kW -HP system, select :EWWP055KAW1+ EWWP065KAW1

1 MODULE (KA-series) 2 MODULES (KA-series) 3 MODULES (KA-series)

EWWP090-130KAW1

EWWP145-195KAW1

The range of chillersEWWP014-065KAW1 can beextended up to 195kW in amodular way.Units EWWP090-195KAW1is a combination of upto 3 modules EWWP045-065KAW1, combined withcontrol box ECB2/3MUW.For configuration guidelines,see below table or contactyour local DAIKIN supplier.

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 39

MOV99091_EPCEN07-400 Page 39 19-MAR-07

Cyan Magenta Yellow Black

Page 40: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Nominal capacity cooling kWheating kW

Power input cooling kWheating kW

EERCOPDimensions (HxWxD) mmMachine weight kgOperation weight kgSound power level (standard/low noise option) dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply Y1Operation range evaporator °C

condenser °CCondenser typeEvaporator typeWater flow rate - evaporator min. l/min

max. l/minMin. water volume in the system lWater flow rate - condenser min. l/min

max. l/minPiping connections type

evaporator water inlet/outletcondenser water inlet/outlet

40

EWWD-MBYNWater-cooled

WATER-COOLED (cooling/heating only) EWWD120MBYN EWWD180MBYN EWWD240MBYN EWWD280MBYN

123 183 249 273147 216 290 32728.7 45.2 61.6 69.234.5 54 72.8 83.44.29 4.05 4.04 3.954.26 4,00 3.98 3.92

1,018x2,681x9301,000 1,273 1,527 1,623

1 1,318 1,588 1,69387/81 93/87 94/88 93/87

Semi-hermetic single screw stepless compressor30-100% stepless

1 1 1 11 1 1 1

R-134a400V/3~/50Hz-10°C ~ 20°C20°C ~ 60°CShell and tube

Brazed plate heat exchanger175 265 350 400700 1,070 1,400 1,600600 890 1,220 1,330217 336 450 520800 1,050 1,230 1,370

Victaulic3"OD 3"2" 1/2 3"

STRENGTHS

• Compact and modular design.• DAIKIN stepless single screw compressor.• Standard reverse phase protection.• VICTAULIC joints.• DICN operation as standard within

same series.• Standard discharge shut-off valve.• Standard filter, flow switch.

OPTIONS (factory mounted)

• Main isolator switch.• Low noise (-5 to -7dB(A)).• Compressor suction stopvalve.• Ampere & Voltmeter

(read-out on switchbox).• Chilled water temperature down to

- 5°C (ZH) or -10°C (ZL).• Dual pressure relief valve.

ACCESSORIES (kit)

• BMS gateway (MODBUS/J-BUS /BACNET protocol).

• Remote user interface (EKRUPC).

CONTROL

• Microprocessor control.• Water inlet or outlet temperature control.• Weekly operating schedule.

AVAILABLE INPUTS/OUTPUTS

Input• ON / OFF.• Pump contact.• Dual setpoint through analog signal.• Floating setpoint.Output• Compressor operation.• Summary alarm (per circuit).• Pump relay contact.

screw

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 40

MOV99091_EPCEN07-400 Page 40 19-MAR-07

Cyan Magenta Yellow Black

Page 41: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

41

Water-cooled

EWWD540MBYNwith low

noise option

WATER-COOLED (cooling/heating only) EWWD360MBYN EWWD440MBYN EWWD500MBYN EWWD520MBYN EWWD540MBYN

366 432 498 522 546431 505 580 617 65590.5 107 123 131 138108 127 146 156 1674.03 4.04 4.05 3.98 3.963.99 3.98 3.97 3.96 3.92

2,000x2,681x9302,546 2,800 3,034 3,150 3,3462,636 2,908 3,156 3,281 3,48596/90 96/90 96/90 96/90 96/90

Semi-hermetic single screw stepless compressor15-100% stepless

2 2 2 2 22 2 2 2 2

R-134a400V/3~/50Hz-10°C ~ 20°C20°C ~ 60°CShell and tube

Brazed plate heat exchanger525 625 700 750 8002,100 2,500 2,800 3,000 3,200895 1,055 1,215 1,275 1,335670 790 900 970 1,0402,100 2,290 2,470 2,600 2,730

Victaulic3"3"

Nominal capacity cooling kWheating kW

Power input cooling kWheating kW

EERCOPDimensions (HxWxD) mmMachine weight kgOperation weight kgSound power level (standard/low noise option) dBACompressor typeCapacity stepsNumber of compressorsNumber of refrigerant circuitsRefrigerant typePower supply Y1Operation range evaporator °C

condenser °CCondenser typeEvaporator typeWater flow rate - evaporator min. l/min

max. l/minMin. water volume in the system lWater flow rate - condenser min. l/min

max. l/minPiping connections type

evaporator water inlet/outletcondenser water inlet/outlet

EWWD120MBYN

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 41

MOV99091_EPCEN07-400 Page 41 19-MAR-07

Cyan Magenta Yellow Black

Page 42: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Daikin fan coil units offer you a quiet, reliable and comfortable solution of airconditioning. Connected to a water chiller, heat pump or hot water boiler, they providecooling and/or heating when and where required. Their timeless and elegant designand whisper quiet fan make them ideal for use in offices, hotels and even at home.

TABLE OF CONTENTS FWV low wall unit from 1.54 to 8.02kW

FWL flexi type from 1.54 to 8.02kW

FWM concealed flexi type from 1.54 to 8.02kW

FWB small duct from 2.61 to 10.34kW

FWD duct unit from 3.90 to 18.3kW

42 Fan coil units

FWV02C

FWL03CFWL03C

FWB04AT

FWM03C

FWD12A

FWM03C

FWD12A

The new range of fan coil units offers a widechoice of 5 models, 3 of which are flexible inapplication (horizontal or vertical installation). Tocomplete our portfolio, a wide range of optionsand accessories is available.

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 42

MOV99091_EPCEN07-400 Page 42 19-MAR-07

Cyan Magenta Yellow Black

Page 43: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Fan coil units

COOLING total capacity (H) kWsensible capacity (H) kWwater flow l/hpressure drop kPa

HEATING heating capacity (H) kWwater flow l/hpressure drop kPa

Power input max. WCoil water volume lAir flow (H/M/L) m3/hSound power level H/M/L dBAWeight FWV kg

FWL kgFWM kg

COOLING total capacity (H) kWsensible capacity (H) kWwater flow l/hpressure drop kPacooling coil water volume l

HEATING heating capacity (H) kWwater flow l/hpressure drop kPaheating coil water volume l

Power input max. WAir flow H/M/L m3/hSound power level H/M/L dBAWeight FWV kg

FWL kgFWM kg

Water connections inchMax. operating pressure barMax. absorbed current ADimensions FWV/FWL mm

FWM mmPower supply V/~/Hz

FWV/FWL/FWM01-10C** 01 02 03 04 06 08 10

1.54 2.09 2.93 4.33 4.77 6.71 8.021.20 1.51 2.11 3.15 3.65 4.91 5.96265 359 504 745 820 1,154 1,34313 13 11 12 14 12 192.14 2.57 3.81 5.63 6.36 7.83 11.1265 359 504 745 820 1,154 1,4989 11 9 9 10 9 1337 53 56 98 98 182 2440.5 0.7 1 1.4 1.4 2.1 2.1

319/233/178 344/271/211 442/341/241 706/497/361 785/605/470 1,011/771/570 1,393/1,022/64245/39/33 50/44/38 47/41/33 52/43/35 56/49/43 61/54/47 66/59/49

19 20 25 30 31 41 4120 21 27 32 33 44 4414 15 19 23 23 32 32

1.46 1.90 2.87 4.33 4.67 6.64 7.881.14 1.51 2.07 3.15 3.57 4.85 5.85251 327 494 745 803 1,142 1,35513 13 11 12 14 12 190.5 0.7 1 1.4 1.4 2.1 2.11.90 2.10 3.08 5.05 5.30 7.91 9.30196 182 286 396 465 694 8167 8 5 10 10 8 9

0.2 0.2 0.3 0.4 0.4 0.6 0.637 53 56 98 98 182 244

307/225/174 327/261/205 431/332/238 690/490/356 763/593/460 998/765/565 1,362/1,007/63645/39/33 50/44/38 47/41/33 52/43/35 56/49/43 61/54/47 66/59/49

20 21 26 32 33 44 4421 22 28 34 35 46 4615 16 20 25 25 34 34

1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4"10 10 10 10 10 10 100.17 0.24 0.25 0.44 0.43 0.80 1.12

564x774x226 564x984x226 564x1,194x226 564x1,404x251535x584x224 535x794x224 535x1,004x224 535x1,214x249

230/1/50

2-pi

pe4-

pipe

2-pi

pe/4

-pip

e

Legend:** : TN (2-pipe, without valves) - TV (2-pipe, with ON/OFF valves) - FN (4-pipe, without valves)

FWV/FWL/FWM

43

OPTIONS FWV / FWL / FWM

Additional single row heat exchanger*Electric heater**2-pipe ON-OFF 3-way motor driven valve with complete mounting kit*4-pipe ON-OFF 3-way motor driven valve with complete mounting kit*(**)

Fan stop thermostat** (only for ECFWMB6)Air intake & discharge grille + front filter fixing kit for concealed modelsSupporting feet (= supporting brackets + covers)Supporting feet + grilleManual fresh air intake louverRear panel for vertically installed unitsController - electromechanical built-in**Controller - electronic built-in + water probe**Controller - electronic remote + water probePower interface for connection of up to 4 FCU to a single control panelVertical drain panHorizontal drain pan

Option description 01 02 03 04 06 08 10 FWV FWL FWM

ESRH02A6 ESRH03A6 ESRH06A6 ESRH10A6 x x xEEH01A6 EEH02A6 EEH03A6 EEH06A6 EEH10A6 x x x

E2MV03A6 E2MV06A6 E2MV10A6 x x xE4MV03A6 E4MV06A6 E4MV10A6 x x x

YFSTA6 x x xEAIDF02A6 EAIDF03A6 EAIDF06A6 EAIDF10A6 - - x

ESFV06A6 ESFV10A6 x - xESFVG02A6 ESFVG03A6 ESFVG06A6 ESFVG10A6 x - -EFA02A6 EFA03A6 EFA06A6 EFA10A6 x - xERPV02A6 ERPV03A6 ERPV06A6 ERPV10A6 x x -

ECFWMB6 x x -ECFWEB6 x x -ECFWER6 x x xEPIMSA6 x x xEDPVA6 x x xEDPHA6 - x x *C

anbe

ordere

dfact

orymo

unted

**fac

torym

ounte

donr

eque

st

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 43

MOV99091_EPCEN07-400 Page 43 19-MAR-07

Cyan Magenta Yellow Black

Page 44: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

COOLING total capacity (H) kWsensible capacity (H) kWwater flow l/hpressure drop kPa

HEATING heating capacity (H) kWwater flow l/hpressure drop kPa

Machine weight kgDimensions (HxWxD) mmHEATING heating capacity (H) kW

water flow l/hpressure drop kPa

Air flow rate m3/hPower input (H) WMax. absorbed current AAvailable static pressure PaSound power level (H) dBAPower supply

44

OPTIONS FWB

FWB2-

pipe

/4-p

ipe

FWB02-10AT

2-p

ipe

Add.

heat

exch.

(*) In combination with ECFWER6, EPIMSA6 or EPIA6 must be installed for FWB08-10

Option description

Additional heat exchanger

3-way valve std h/e

3-way valve add. h/e

2-way valve std h/e

2-way valve add. h/e

Electric heater

Fan stop thermostat

Power interface (*)

Master slave interface (*)

Controller electronic - remote

02 03 04 05 06 07 08 09 10

EAH04A6 EAH07A6 EAH10A6

Factory mounted on request

E2MV307A6 E2MV310A6

Factory mounted on request

E2MV207A6 E2MV210A6

Factory mounted on request

YFSTA6

- EPIA6

EPIMSA6

ECFWER6

02 03 04 05 06 07 08 09 10

2.61 3.14 3.49 5.08 5.45 6.47 7.57 8.67 10.341.88 2.16 2.34 3.6 3.87 4.4 5.23 5.96 6.9448 539 598 873 936 1,111 1,299 1,488 1,7748 14 11 15 8 14 21 21 26

5.47 6.01 6.47 10.31 11.39 12.28 15.05 16.85 18.78480 527 567 904 999 1,077 1,319 1,479 1,6477 10 8 12 7 10 16 15 1823 24 26 31 33 35 43 45 48

239x1,039x609 239x1,389x609 239x1,739x6093.14 5.99 12.8275 526 1,1233 5 8

400 800 1,200106 192 2940.51 0.94 1.2871 65 5958 60 69

230V/1~/50Hz

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 44

MOV99091_EPCEN07-400 Page 44 19-MAR-07

Cyan Magenta Yellow Black

Page 45: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

FWD

OPTIONS FWD

COOLING total capacity kWsensible capacity kWwater flow l/hpressure drop kPa

HEATING heating capacity kWwater flow l/hpressure drop kPa

Available static pressure PaWeight kgCOOLING total capacity kW

sensible capacity kWwater flow l/hpressure drop kPa

HEATING heating capacity kWwater flow l/hpressure drop kPa

Available static pressure PaWeight kgAir flow rate m3/hPower input (H) WMax. absorbed current ADimensions (HxWxD) mmSound power level (H) dBAPower supply V/~/Hz

FWD04-18A* 04 06 08 10 12 16 18

3.90 6.20 7.80 8.82 11.90 16.4 18.33.08 4.65 6.52 7.16 9.36 12.8 14.1674 1,064 1,339 1,514 2,056 2,833 3,14017 24 24 16 26 34 45

4.05 7.71 9.43 10.79 14.45 19.81 21.92674 1,064 1,339 1,514 2,056 2,833 3,14014 20 20 13 21 28 3766 58 68 64 97 145 13433 41 47 49 65 77 80

3.90 6.20 7.80 8.82 11.90 16.4 18.33.08 4.65 6.52 7.16 9.36 12.8 14.1674 1,064 1,339 1,514 2,056 2,833 3,14017 24 24 16 26 34 45

4.49 6.62 9.21 9.21 15.86 21.15 21.15349 581 808 808 1,392 1,856 1,8569 15 13 13 12 16 1663 53 63 59 92 138 12835 43 50 52 71 83 86800 1,250 1,600 1,600 2,200 3,000 3,000234 349 443 443 714 1197 11970.95 1.58 1.97 1.97 3.21 5.37 5.37

280x754x559 280x964x559 280x1,174x559 352x1,174x718 352x1,384x71866 69 72 72 74 78 78

230/1/50

2-pi

pe4-

pipe

2-p

ipe/

4-p

ipe

Legend:*: T (2-pipe)

F (4-pipe)

45

OPTIONS FWB

FWB

Notes:1. The valves for FWD12-16-18 do not contain piping nor drain pan.2. Requires electronic control.3. Neglecting the absolute requirement to install an additional interface (EPIA6 or EPIMSA6) to FWD06 -->18 may cause fire or other damage to the equipment.4. In combination with ECFWER6, EPIMSA6 or EPIA6 must be installed for FWD06-10.5. In combination with ECFWER6, EPIA6 must be installed for FWD12-18.

Electric heater: small (2)

Electric heater: big (2)

2-pipe 3-way valve (1)

4-pipe 3-way valve (1)

Vertical drain pan

Horizontal drain pan

Fan stop thermostat

Fresh air intake louvers (motorised)

Controller - electronic remote +water probe (3)Master / Slave Interface (4)

Power interface (5)

Option description 04 06 08 10 12 16 18

EDEH04A6 EDEHS06A6 EDEHS10A6 EDEHS12A6 EDEHS18A6

EDEH04A6 EDEHB06A6 EDEHB10A6 EDEHB12A6 EDEHB18A6

ED2MV04A6 ED2MV10A6 ED2MV12A6 ED2MV18A6

ED4MV04A6 ED4MV10A6 2 x ED2MV12A6 2 x ED2MV18A6

EDDPV10A6 EDDPV18A6

EDDPH10A6 EDDPH18A6

YFSTA6

EDMFA04A6 EDMFA06A6 EDMFA10A6 EDMFA12A6 EDMFA18A6

ECFWER6

EPIMSA6 - - -

- EPIA6

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 45

MOV99091_EPCEN07-400 Page 45 19-MAR-07

Cyan Magenta Yellow Black

Page 46: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

MEASURING CONDITIONS

Air-cooled

Remote evaporatorRemote condenser

Water-cooled

Fan coil units

CHILLERS

Cooling Water 7°C / 12°C Ambient temperature : 35°CHeating Water 45°C / 50°C Ambient temperature : 7°C

Suction dewpoint : 5°C Ambient temperature : 35°CCooling Water 7°C / 12°C Condensing temp : 45°C

Liquid temp. : 40°CCooling Evaporator water : 7°C / 12°C Water condenser : 30°C / 35°CHeating Evaporator water : 7°C / 12°C Water condenser : 40°C / 45°CCooling Room temperature : 27°C / 19°C

Entering water temperature: 7°C / 12°CHeating Room temperature : 20°C

Entering water temperature: 50°C (2-pipe) • 70°C (4-pipe)

46

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 46

MOV99091_EPCEN07-400 Page 46 19-MAR-07

Cyan Magenta Yellow Black

Page 47: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

MEASURING CONDITIONS

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 47

MOV99091_EPCEN07-400 Page 47 19-MAR-07

Cyan Magenta Yellow Black

Page 48: Great in cooling and heating...- FOR HIGH CAPACITY The heart of the larger Daikin chillers is a semi hermetic singlescrewcompressor,designed,testedandmanufactured in Daikin’s own

Naamloze Vennootschap

Zandvoordestraat 300

B-8400 Ostend, Belgium

www.daikin.eu

BTW: BE 0412 120 336

RPR Oostende

EPC

EN07

-400

/50

0/

03/0

7La

Mov

ida

The

pres

ent

publ

icat

ion

supe

rsed

esEP

CE0

4-15

C.

Prin

ted

onno

n-ch

lorin

ated

pape

r/

Prin

ted

inBe

lgiu

mC

opyr

ight

©D

aiki

n

Daikin units comply with the European regulationsthat guarantee the safety of the product.

Daikin Europe NV participates in the EuroventCertification Programme for Air Conditioners(AC), Liquid Chilling Packages (LCP) and Fan CoilUnits (FC); the certified data of certified modelsare listed in the Eurovent Directory.

Daikin Europe N.V. is approved by LRQA for its QualityManagement System in accordance with the ISO9001standard. ISO9001 pertains to quality assuranceregarding design, development, manufacturing aswell as to services related to the product.

ISO14001 assures an effective environmentalmanagement system in order to help protecthuman health and the environment from thepotential impact of our activities, products andservices and to assist in maintaining and improvingthe quality of the environment.

Daikin products are distributed by:

The present catalogue is drawn up by way of information only and does not constitute an offer binding upon DaikinEurope N.V.. Daikin Europe N.V. has compiled the content of this catalogue to the best of its knowledge. No expressor implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its contentand the products and services presented therein. Specifications are subject to change without prior notice. DaikinEurope N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or relatedto the use and/or interpretation of this catalogue. All content is copyrighted by Daikin Europe N.V..

EPCEN07-400:EPCEN07-400 12/03/07 15:16 Page 48