GreCon Spark Detection and Extinguishing System
Product Presentation
Innovation is our tradition
![Page 2: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/2.jpg)
2
Content
Why sparks are so dangerous!
Safety for your individual production with Spark Extinguishing
Systems
Applications
Components
Safety Control
Customer Support and Services
References - Approvals - Certifications
Innovation is our tradition
![Page 3: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/3.jpg)
3
Fire can be beautiful…
Innovation is our tradition
![Page 4: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/4.jpg)
4
… but Fire can become very dangerous!
Innovation is our tradition
![Page 5: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/5.jpg)
5
Statistics about Losses and Damages after Industrial Fires
Innovation is our tradition
43 % did not recover
26 % endure fire 15 % lost credit worthiness
17 % could not show balance sheet
Font: Dr.-Ing. Mingyi Wang, VDS Verband d. Dtsch. Vers. Wirtschaft,
Großschadenstatistik in der industriellen Sachversicherung 2001 GDV, Berlin.
Loss of
Public Image
![Page 6: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/6.jpg)
6
Just a spark?
Innovation is our tradition
![Page 7: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/7.jpg)
7
Innovation is our tradition
One
SPARK
can be enough
![Page 8: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/8.jpg)
8
Sparks 32.7%
Burning Embers 12.7%
Electrostatics 8.5%
Fire (Power Plants) 7.9%
Self Ignition 6.0%
Hot Surfaces 4.8%
Welding 4.2%
Electrical Defects 3.2%
Others 3.0%
Unknown 17.0%
More than 45 % of fires are caused by sparks or burning embers
Innovation is our tradition
![Page 9: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/9.jpg)
9
Innovation is our tradition
If sparks cause
explosions
production facilities
are destroyed
and human life
is endangered!
![Page 10: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/10.jpg)
10
Complete Factories were destroyed!
Innovation is our tradition
![Page 11: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/11.jpg)
11
Silos / Bins 34.7%
Filters / Dust Extractions 20.3%
Dryers 9.6%
Burners / Power Plants 9.0%
Mills / Shredders 9.0%
Sieves / Separators 5.4%
Conveying Systems 4.2%
Sanders 3.6%
Others 4.2%
In which areas do explosions mainly occur / start?
Innovation is our tradition
![Page 12: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/12.jpg)
12
Silos
Innovation is our tradition
![Page 13: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/13.jpg)
13
Filters
Innovation is our tradition
![Page 14: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/14.jpg)
14
Dryers
Innovation is our tradition
![Page 15: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/15.jpg)
15
Mills
Innovation is our tradition
![Page 16: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/16.jpg)
16
Sieves
Innovation is our tradition
![Page 17: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/17.jpg)
17
Conveying Systems
Innovation is our tradition
![Page 18: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/18.jpg)
18
Production line – Wood Based Panel Industry
Innovation is our tradition
![Page 19: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/19.jpg)
20
Innovation is our tradition
Extinguish
before
Ignition!
![Page 20: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/20.jpg)
21
Content
Why sparks are so dangerous!
Safety for your individual production with Spark Extinguishing
Systems
Applications
Components
Safety Control
Customer Support and Services
References - Approvals - Certifications
Innovation is our tradition
![Page 21: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/21.jpg)
22
AFTER start of fire
the fire needs to be fighted
Fire spread has to be avoided
Damages need to be minimized
Conventional Fire Fighting Systems
Sprinkler
Deluge Systems
Innovation is our tradition
![Page 22: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/22.jpg)
23
GreCon Spark Detection and Extinguishing System
BEFORE start of fire
By preventive fire protection
Ignition energy is eliminated
Innovation is our tradition
![Page 23: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/23.jpg)
24
Principle of spark detection and extinguishment
Innovation is our tradition
Ignition sources
like sparks
or hot glowing particles
are extinguished
– before they reach filters or silos!
![Page 24: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/24.jpg)
25
Content
Why sparks are so dangerous!
Safety for your individual production with Spark Extinguishing
Systems
Applications
Components
Safety Control
Customer Support and Services
References - Approvals - Certifications
Innovation is our tradition
![Page 25: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/25.jpg)
26
Protection concept for filters
Spark Detector FM
Extinguishing Device
Thermal Detector
Daylight / Spark Detector
Innovation is our tradition
F
F
M
Further concepts according to your individual process available!
![Page 26: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/26.jpg)
27
Protection concept for dryers
Spark Detector FM
Extinguishing Device
Innovation is our tradition
Further concepts according to your individual process available!
![Page 27: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/27.jpg)
28
Protection concept for mills / ginding machines
Innovation is our tradition
Further concepts according to your individual process available!
Spark Detector FM
Extinguishing Device
![Page 28: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/28.jpg)
29
Protection concept for industrial sanding
Spark Detector FM
Thermal Detector
Extinguishing Device
Innovation is our tradition
Further concepts according to your individual process available!
![Page 29: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/29.jpg)
31
Content
Why sparks are so dangerous!
Safety for your individual production with Spark Extinguishing
Systems
Applications
Components
Safety Control
Customer Support and Services
References - Approvals - Certifications
Innovation is our tradition
![Page 30: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/30.jpg)
32
Main components of the GreCon Spark Extinguishing System
Innovation is our tradition
o Infrared detectors
o Temperature detectors
o Flame detectors
o Combustion gas detectors
o Smoke detectors
o Flexible, modular design o Extinguishing Devices
o Fire traps / Shut-off
o Diversion Gates
o Use of existing facilities (reversing,
switching, stopping)
Control console Spark Elimination Detection
Based on your process, an individual protection concept is developed with these components
![Page 31: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/31.jpg)
33
Sensor element out of silicium (Si)
Pneumatic transport ducts with (high) load
Drop chutes with high bulk density
Applications without light ingress (false alarms)
Spark detector FM 1/8
Spark detector FM 3/8
Sensor element out of lead sulphide (PbS)
With light ingress
Lower sensitivity (1/300 compared with silicium)
Daylight detector DLD 1/8
Sensor element out of lead selenide (PbSe)
Detection of hot particles (no sparks)
Suitable for applications with process-related spark flight
Hot particle detector HPD 1/8
IR detector with application-specific sensor elements
Innovation is our tradition
![Page 32: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/32.jpg)
34
Physics of Spark Detection
Innovation is our tradition
![Page 33: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/33.jpg)
35
Physics of Spark Detection
Innovation is our tradition
FM
Highest sensibility
Can look through the material
Place of installation: Ducts and drop chutes
DLD
Detect sparks under daylight conditions
Place of installation: Conveyors, open ducts
HPD
Optimized for the detection of hot
particles
Place of installation: e.g. chute
after a shredder
![Page 34: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/34.jpg)
36
Spark detector FM 1/8 with silicium element
Highly sensitive spark detector
(Si element)
Installation in transport ducts
and drop chutes
Reliable detection of ignition sources
within the product flow, even at high
material load and pollution
Flush-mounted installation of the detector
optics for maximum life
Spark detector FM 1/8
Innovation is our tradition
![Page 35: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/35.jpg)
37
Spark detector FM 3/8 with Si element and fibre optic cable
Highly sensitive spark detector
(Si element)
For use at high operating temperatures
(up to 600 °C) with fibre optic cables
High detection reliability by using three
detection elements
Spark detector FM 3/8 with fibre optic cables
Innovation is our tradition
![Page 36: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/36.jpg)
38
Daylight detector DLD 1/8 with lead sulphide element
Spark detector for light ingress
(PbS element)
Installation in processes
with daylight ingress
Daylight detector DLD 1/8
Innovation is our tradition
![Page 37: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/37.jpg)
39
Hot particle detector HPD 1/8
Suitable for applications
with process-related spark flight
Installation in extraction systems of
hardening shops or recycling plants,
for example
Hot particle detector HPD 1/8
for detection of smouldering fires and hot particles
Innovation is our tradition
![Page 38: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/38.jpg)
40
Thermal detector TM 1/9
Innovation is our tradition
Collateral trigger functions
Alarm upon fire-typical temperature rise
Alarm upon exceeding
of a set temperature threshold
Thermo detector TM 1/9
for temperature monitoring
![Page 39: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/39.jpg)
42
Flame detector FD 1/8
Detection with dual UV/IR technology
Insensitive to light ingress
Heated optic for application
in difficult conditions
Early alarm by UV channel in case of
arising fire (manual extinguishment)
If the fire continues to spread, the UV
alarm will be confirmed by the IR channel
(automatic extinguishment)
Application for press extinguishment,
for example Flame detector FD 1/8
for detection of open flames
Innovation is our tradition
![Page 40: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/40.jpg)
43
Scattered light smoke detector SRM 9/1
Detection of fires that develop smoke,
e.g. in return-air ducts of dust filters
Application for fire detection in
dust-free areas
Scattered light smoke detector SRM 9/1
Innovation is our tradition
![Page 41: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/41.jpg)
44
Purge air
Air flow
Purged air is used to keep the sensor lense clean
Dirt particles are removed hrough the air flow continuously
Additional Detector Component – Air Purge Adapter
Air purge adapter
Innovation is our tradition
![Page 42: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/42.jpg)
45
Additional Detector Component - Slotted diaphragm for optimisation of the detection performance
Slotted diaphragm
Shielding against ambient light
(artificial light or daylight)
Focus of sensor range
Increased contrast
Application mainly in combination
with thermo detector
Innovation is our tradition
![Page 43: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/43.jpg)
46
Flush-mounted on the inside wall
for a long life
Drill Installation Adapter is mounted
Insert detector Attach cable
Easy installation of the detectors
Innovation is our tradition
![Page 44: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/44.jpg)
47
Spark Eliminiation
Extinguishing with water
Fast
Cheap
No process interruption
Extinguishing with gas
Inerting
Use of the existing facilities Reversing
Switching
Stopping
Mechanical diversion or shutoff Processes where water cannot be used
(e.g. food, coffee etc.)
Innovation is our tradition
![Page 45: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/45.jpg)
48
Reliable spark extinguishing with minimum water
Theoretical cornerstones
The smaller the drop,
the shorter the throw distance
The finer the water mist,
the larger the water surface
The finer the water mist,
the less water gathers in the pipes
Minimal use of water by optimum
adaptation of cooling effect and throw
distance
The ideal drop size – as small as possible and as big as necessary
Drop size
Number of drops
Innovation is our tradition
Drop size of hollow-cone nozzle
![Page 46: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/46.jpg)
49
Optimum distribution of the water mist spray
with minimal wetting of the pipe wall
The dynamic spray pattern is decisive! spraying profile of hollow-cone nozzle
static spray pattern
dynamic spray pattern
Innovation is our tradition
![Page 47: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/47.jpg)
50
Short reaction time
Immediate closure of the shutter cone after extinguishment
Electrically monitored ball valve
Integrated flow test switch
Extinguishing device for fine and efficient water mist
Extinguishing nozzle
Valve
Ball valve
Flow test
Strainer
Innovation is our tradition
![Page 48: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/48.jpg)
51
Reduction of reaction distance by ultrahigh-speed extinguishment
Innovation is our tradition
![Page 49: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/49.jpg)
52
Easy installation of extinguishing nozzles
Flush-mounted on the inside wall
for a long life
Drill Installation of adapter Tighten firmly
Screw nozzle Finished!
Innovation is our tradition
![Page 50: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/50.jpg)
53
Additional Extinguishing Component - Anti-freeze protection
Isulating bags
(optional with integrated heating)
Universally suitable for all
extinguishing devices
Weatherproof
Solid hook-and-loop fastener
Heater band to heat water-bearing pipes
Self-regulating
Optional 10 or 20 W/m
Heater band control
Incl. undercurrent monitoring
Innovation is our tradition
![Page 51: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/51.jpg)
54
Consisting of:
Storage tank
Pump
Pressure vessel
Dosing unit for detergent agent
Pressure increasing units to create the required water pressure / water flow rate
Innovation is our tradition
![Page 52: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/52.jpg)
55
Fire traps and diversion gates to shut off the product flow
Reaction time approx. 250 ms
Available in stainless steel 1.4301
Innovation is our tradition
![Page 53: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/53.jpg)
56
Reaction time approx. 250 ms
Available in stainless steel 1.4301
High-speed diversion gate is suitable for fine-grained products
Diversion gates to divert the product flow
Innovation is our tradition
![Page 54: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/54.jpg)
57
Suitable control consoles for any project size
Up to 4 detection points
Up to 16 detection points
(optional extension)
Up to 36 detection points
(optional extension)
(400 x 600 x 200 mm)
(800 x 600 x 300 mm) (2200 x 800 x 600 mm)
Innovation is our tradition
![Page 55: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/55.jpg)
58
Content
Why sparks are so dangerous!
Safety for your individual production with Spark Extinguishing
Systems
Applications
Components
Safety Control
Customer Support and Services
References - Approvals - Certifications
Innovation is our tradition
![Page 56: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/56.jpg)
59
User-friendly operation by GreCon BS 7 TOUCH
Intuitive operation = safe operation
Important information quickly available
Extensive analysis possibilities for
inividual areas and export of data
Remote support (SATELLITE)
Touch & slide operation on the housing front
Innovation is our tradition
![Page 57: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/57.jpg)
60
From alarm overview to detailed information
Innovation is our tradition
overview of all areas Flowsheet alarm zone Zone details
![Page 58: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/58.jpg)
61
Data storage exactly to the millisecond for extensive analyses
Numerous evaluation possibilities
directly on the display
Zones
Innovation is our tradition
![Page 59: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/59.jpg)
62
Data storage exactly to the millisecond for extensive analyses
Numerous evaluation possibilities
directly on the display
Zones
Types
Innovation is our tradition
![Page 60: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/60.jpg)
63
Data storage exactly to the millisecond for extensive analyses
Numerous evaluation possibilities
directly on the display
Zones
Types
Time
Innovation is our tradition
![Page 61: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/61.jpg)
64
Data storage exactly to the millisecond for extensive analyses
Numerous evaluation possibilities
directly on the display
Zones
Types
Time
Result
Innovation is our tradition
![Page 62: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/62.jpg)
65
Level 1: Detection of sparks
Extinguishment and logging, no further activities
Level 2: Detection of sparks: either time threshold or a certain number of sparks per time unit
(e.g. 20 sparks in 5 seconds)
Shut-down of the appropriate plant area
Level 3: High number of sparks in different groups in a short timeframe
(e.g. 150 sparks in 5 seconds)
Flooding of the whole plant area
Level 4: Level 2 several times after one another
Documentation; basis for further analyses
Exact data for process analysis + detailed Information for the operator
Various alarm levels for optimum protection by individual reactions
Innovation is our tradition
![Page 63: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/63.jpg)
66
A large number of sparks can be the beginning of an explosion!
This cannot be controlled by a spark extinguishing system!
But:
The GreCon spark extinguishing system is able to analyse such incidents and to activate
preventive extinguishing measures.
The extinguishment soaks the material and the damage caused by the explosion is reduced.
Reduction of damage caused by explosion by level 3 alarm
Innovation is our tradition
![Page 64: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/64.jpg)
67
Level 3 alarm using the example of an air separator
Time diff. [s] Alarm 3 [s] Sparks Extinguishing time [s]
L44 0,000 0,386 128 19,378
L45 0,727 0,381 50 6,769
L42 0,751 0,398 94 8,951
L41 0,761 0,390 40 5,941
L43 1,864 0,389 238 15,301
Innovation is our tradition
![Page 65: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/65.jpg)
68
Network Connectivity
Innovation is our tradition
![Page 66: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/66.jpg)
69
Networking by BS 7 NET
Innovation is our tradition
![Page 67: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/67.jpg)
70
Networking by BS 7 NET: zone overview
Innovation is our tradition
![Page 68: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/68.jpg)
71
Networking by BS 7 NET alarm overview of different monitoring zones
Innovation is our tradition
![Page 69: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/69.jpg)
72 Innovation is our tradition
Networking by BS 7 NET alarm overview and spark detection in a monitoring zone
![Page 70: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/70.jpg)
73
Networking by BS 7 NET
Innovation is our tradition
detailed view of the history
![Page 71: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/71.jpg)
74
Content
Why sparks are so dangerous!
Safety for your individual production with Spark Extinguishing
Systems
Applications
Components
Safety Control
Customer Support and Services
References - Approvals - Certifications
Innovation is our tradition
![Page 72: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/72.jpg)
75
Worldwide network of highly qualified after-sales
engineers.
Quick reaction for failure removal,
assembly and commissioning.
Low costs thanks to short travelling distances.
Remote support SATELLITE
(highest certified safety standard).
Maintenance aggreements
Customer Support and Services
Innovation is our tradition
![Page 73: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/73.jpg)
76
Transfer of knowledge for the operation,
application and technical support of our products.
Experience and knowledge of decades
are available for you.
Training courses at the Academy in Alfeld as well
as internal training courses.
GreCon Academy
Innovation is our tradition
![Page 74: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/74.jpg)
77
Content
Why sparks are so dangerous!
Safety for your individual production with Spark Extinguishing
Systems
Applications
Components
Safety Control
Customer Support and Services
References - Approvals - Certifications
Innovation is our tradition
![Page 75: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/75.jpg)
78
Competence since 1973
Approx. 200.000 monitoring zones installed worldwide in more than 100 industries
Full service out of one hand
Quality „Made in Germany“
References
Innovation is our tradition
![Page 76: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/76.jpg)
79
International approvals
Innovation is our tradition
![Page 77: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/77.jpg)
80
International association activities
Innovation is our tradition
![Page 78: GreCon Spark Detection Systems - Rommel · 32 Main components of the GreCon Spark Extinguishing System Innovation is our tradition o Infrared detectors o Temperature detectors o o](https://reader034.vdocument.in/reader034/viewer/2022051812/602e6a7923a53d43bc1f33a9/html5/thumbnails/78.jpg)
81
Extinguish before Ignition