grid tie micro inverter photovoltaic grid tie · pdf fileusing screw driver (not supplied) ......

Download Grid Tie Micro Inverter Photovoltaic Grid Tie · PDF fileUsing screw driver (not supplied) ... Cables 400W 500W 600W Cable Length 3M length or less 3M length or less 3M length or less

If you can't read please download the document

Upload: trinhdien

Post on 09-Feb-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • Productmodel:400W/500W/600W/1000/1200W

    Photovoltaic Grid Tie Inverter

    Installation and Operation Manual

    High-frequency Series Grid Tie Micro Inverter

    www.soyo-dg.com

    SOYO Copyright 2015cDongguan SOYO New Energy Technology Co.,Ltd Rights Reserved

  • 1

    1.1 Important notice---------------------------------------------------------021.2 Suitability-----------------------------------------------------------------021.3 Package content --------------------------------------------------------02

    2.1 safety precaution--------------------------------------------------------022.2 User guidance -----------------------------------------------------------02

    3.1 Product guide ------------------------------------------------------------033.2 Special features ---------------------------------------------------------033.3 Structural guide----------------------------------------------------------043.4 LED indicators -----------------------------------------------------------043.5 Work mode -------------------------------------------------------------- 05

    5.1 Installation environment -----------------------------------------------065.2 Installation position ----------------------------------------------------075.3 Installation method ----------------------------------------------------- 09

    6.1 Cabling requirement-----------------------------------------------------116.2 Cabling instruction-------------------------------------------------------116.3 AC cable connection-----------------------------------------------------126.4 DC cable connection----------------------------------------------------126.5 Trial operation -----------------------------------------------------------15

    7.1 Technical specifications -----------------------------------------------15

    8.1 Quality assurance-------------------------------------------------------178.2 Contact us ----------------------------------------------------------------188.3 Disclaimer ----------------------------------------------------------------18

    --------------------------------------------------------------19

    1. Manual Instruction

    2. Safety precaution and guidance

    4. Fault finding and troubleshooting

    5. Installation

    6. Electrical connections and trial operation

    7. Appendix A

    8. Appendix B

    Warranty card

    Table of Contents

    V1.5 SOYO Copyright 2015c

    PV Grid Micro Inverterwww.soyo-dg.com

    3. Introduction to the SOYO series Grid-tied in-verter

  • 1. Manual Instruction

    1.1 Important notice

    1.2 Suitability

    1.3 Package content

    2. Safety precaution and Guidance

    2.1 Safety precaution

    For installation and operation purpose, please read this manual carefully beforeproceeding. This manual includes how the SOYO series Grid-tied inverter shouldbe handled, including transportation, installation, operation, maintenance, andtroubleshooting should any unexpected error occurred while in use.

    This user manual covers the SOYO series of Grid-tied inverters.

    Please check package content when product is in your possession. We do our bestto ensure the content of package to be correct, and necessary precaution is takenon packaging at factory to prevent damages caused during transportation, however,if there was any unforeseeable circumstances that lead to damaging of goodsbefore reaches you, DO NOT proceed with installation, kindly let your dealer knowabout it, or call our service department to resolve your situation. We promise youthe utmost satisfactory on either our products or after sales services.

    For installation and operation, please read this manual carefully before proceeding.If for reasons the product was installed improperly or handled incorrectly, resultingin an unworkable product, we DO not hold responsibility for such actions.

    2

    Warning!

    2.2 User guidancea.

    b.

    c.

    d.

    3. Introduction to the SOYO series Grid-tied inverter

    The inverter's safe and sound operation, correct way of transporting,storing, assembling, installing, operating, and servicing the unit.

    All operations and cabling connections must be done by proper electricians ormechanical engineers, and electric power installation to be in compliance with localelectricity codes.

    Prior to inspecting and servicing the unit, ensure a good multi-meter is used tocheck that NO AC or DC voltages existed in the unit before proceeding.

    Follow the procedure listed in this manual, strictly work in accordance with thesafety precautions and hazardous signages.

    The SOYO series Grid-tied inverter is used in photovoltaic system, it maximises theoutput of photovoltaic solar energy from solar modules, and allows the energy to beconverted and fed through the power utility grid for normal everyday uses.

    V1.5SOYO Copyright 2015c

    PV Grid Micro Inverterwww.soyo-dg.com

    Let a professional do the installation and operationof the SOYO series Grid-tied inverter.

    Be sure all the important points in this manual arenoted before proceeding.

  • 3.1 Product explained A Grid-tied photovoltaic system is made up of panels consisting solar modules toreceive PV arrays, from here the solar energy is collected and formed as a directelectrical current, feeding through a Grid-tied inverter, transforms from DC to AC, thengoes through a metering device, measuring and recording the amount of energygenerated by the system, before feeding the power to the local utility grid. Our SOYOseries Grid-tied inverters play an important role by ensuring the whole transformingprocess is safely conducted, converting DC from solar system into single phase ACwith correct voltages, same frequencies and phase, and the output sinewaves of theAC power totally matches our everyday used electricity. (figure 3-1-1)

    3

    Solar panel system

    Photovoltaic grid=connected inverter

    Electricity metering equipment

    Utility grid

    Photovoltaic grid-connected powering system

    (feature 3-3-1)

    3.2 Special features

    (1).

    (2).

    (3).(4).

    (5).

    (6).

    (7).

    (8).

    (9).

    Our SOYO series Grid-tied inverter uses high speed and high specification MCUfrom USA, so as to achieve a more efficient workingCondition and better result in our system.

    Advanced technology of Multi Power Point Tracking (MPPT) device in oursystem enhanced the maximum arrays to be collected.

    High efficiency of MPPT is recorded to be over 99%.Parallel connection on input of solar energy battery enable simple adjustment of

    the power rate for the utility grid.

    High efficiency on the design of High Frequency Transformer.

    Advanced Anti-island technology.

    High performance EMC technique on system protection, advanced modulardesign, ensuring safety and reliability on our systems.

    LED indicators distinctively showing status of system.

    Portable size and light weight makes our inverter easy to install, operate, andmaintain.

    V1.5 SOYO Copyright 2015c

    PV Grid Micro Inverterwww.soyo-dg.com

  • 3.4 LED indicators

    4

    LED Status FunctionsSystem not switched on, or systemnot connected to solar panel

    PV Voltage or Gid frequencyexceeds permitted range

    System in normal working order

    Input Voltage exceeds MPPTtracking permitted range

    System on tracking the maximumeffiency point of sun lighting

    system locked on the maximumeffiency point of sun lighting

    System in normal workingtemperature, 45 C

    System is starting to overheat, >60 C, switch output to off, whentemperature cools down to below 45 C, device back on to work.

    light off

    Indicatorred

    Indicatorgreen

    Indicatorblue

    light on

    Flashing

    light off

    light on

    Flashing

    light off

    Flashing

    light on

    Power

    APC

    HEAT

    (feature 3-3-1)

    Circuit diagram

    Solar panel systemTransformer

    Inverter bridgeEMC filter

    Grid

    3.3 Structural guide (feature 3-3-1)

    V1.5SOYO Copyright 2015c

    PV Grid Micro Inverterwww.soyo-dg.com

  • 3.5 Work mode

    (1)

    (2)

    (3)

    (4)

    4. Fault finding and troubleshooting

    5. Installation

    SOYO series grid-tied inverter has an automated working order, without needing tomonitor. On detection the power output from solar panels, device will decide if thepower was large enough to begin the conversion process. Coversion processincludes 5 modes, Startup, Grid-tied begin, Standby, Stop, Fault-find.

    Startup - When the start button is on, solar panel and grid lines both connectedin normal condition, inverter enters working condition.

    Grid-tied begin - Grid-tied begin mode is when inverter starts to convert theDirect Current fed through from PV solar panel to a stable Alternate Current andflow to the utility grid. To enable the maximum output of energy, the device usesMPPT control technology to track sun rays, this technology promises the maximumefficiency under diferent daylight and temperature conditions.

    Standby - Standby mode is when device detects insufficient power feedingthrough from the solar panel, or device detects abnormal status such as voltages,frequencies, and temperatures not in the permitted range, the device entersstandby mode.

    Stop - Insufficient sunlight hence insufficient PV power feeding through to thedevice and device enters into the standby mode, when this condition continues andDC voltages falls below 12V for over 1 minute, the device will enter Stop mode.

    When error ocurs, fault find indicator starts flashing, device will enter Stop mode.Please see 3.4 error status on LED indicator.

    Prior installation, please read t