group n3: digital control
DESCRIPTION
Group N3: Digital Control. Mary Nsunwara Wayne Blake Reshun Gethers. Current Design Issues. EMG Circuit Will previous design work Signal Source & Usage Which muscles to monitor A/D Converter & Software Need PCI connection. Current EMG Circuit. Specifications. Gain: 20,000 - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/1.jpg)
Group N3: Digital ControlGroup N3: Digital Control
Mary Nsunwara
Wayne Blake
Reshun Gethers
![Page 2: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/2.jpg)
Current Design IssuesCurrent Design Issues
EMG Circuit–Will previous design work
Signal Source & Usage –Which muscles to monitor
A/D Converter & Software– Need PCI connection
![Page 3: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/3.jpg)
Current EMG CircuitCurrent EMG Circuit
![Page 4: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/4.jpg)
SpecificationsSpecifications
Gain: 20,000Gain: 20,000Bandwidth: 1.7 - 34 HzBandwidth: 1.7 - 34 Hz Input Impedance: 10 MInput Impedance: 10 M CMRR: 100dBCMRR: 100dB
![Page 5: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/5.jpg)
Other EMG ConsiderationsOther EMG Considerations
MindTel TNG-3B
![Page 6: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/6.jpg)
MindTel TNG-3BMindTel TNG-3B
Is an actual electromyogramHas serial port connectionData rate: 19.2 kbpsCost: $150
![Page 7: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/7.jpg)
TNG-3B SoftwareTNG-3B Software
Managed by NeatTools Software– Utilizes flow chart diagrams– No hard coding required
![Page 8: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/8.jpg)
Current A/D ConverterCurrent A/D Converter
Keithley DAS-1701ST-DA –Max sampling rate: 160 kb/s – Input ranges: 0 - 5V, 1V, 100mV, 20mV – Gains: 1, 5, 50, 250– Uses DriverLINX Package Software– Does not have a PCI connection
![Page 9: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/9.jpg)
Signal Source OptionsSignal Source Options
Eyebrows– Good contraction speed– Difficult to move one eyebrow– Low fat tissue coverage
Jaw muscles– Better contraction speed– Easier to bite on one side of mouth– Usually covered by more fat tissue
![Page 10: Group N3: Digital Control](https://reader035.vdocument.in/reader035/viewer/2022062500/568158a8550346895dc5fd6a/html5/thumbnails/10.jpg)
Current Design GoalsCurrent Design Goals
Front End– Build and test current EMG circuit
– Acquire a transferable A/D converterBack End– Determine best way to signal the RC
device