gruenberg steridry™ sterilizers dry heat sterilization ... · hold the steam dry heat...
TRANSCRIPT
WHY GRUENBERG DRY HEAT
STERILIZATION?
• Designassistancefromleaderin
labanimalsciencesterilization
• Lowesttotalcostofownership
• Greateroutputinasmallerfootprint
• Saferoperation
• Extendedcagelife
• Healthierenvironment(lessheat,
lessmoisture)
• PrecisionFloTM
GRUENBERG STERIDRY™ STERILIZERS
DRY HEAT SterilizationLower Cost, Worry-Free & Green
Hold the SteamDry heat sterilization systems use forced-air convection
technology for reduced energy consumption.
Pharmaceutical,MedicalDeviceand
LifeScienceResearchsterilizationhas
recentlyseenademandforgreener
technologiesthatrequirelessmaintenance.
Thisputsthepressureonequipment
engineerstodevelopinnovativewaysto
approachsterilization.Whiletraditional
steamautoclavesusewater;dryheat
sterilizationprovidesanalternativeto
steamthatusesnowater,lessenergy,
andrequireslessmaintenance.
Comparedwithsteam;dryheatisa
greenertechnologythateliminates
waterusage,providesmoreflexibility
forinstallationlocations,andcostsless
toownandoperate.
Moderndryheatsterilizationsystems
usingfocusedforcedairconvection
technologyareconsistentlydecreasing
thecycletime.Dependingontheload
configurationandcooldownrequirements,
thetypicalcyclelastslessthan3hours.
Theinitialcostofavailabledryheat
systemsisabout60%ofequivalent
sizedsteamautoclaves.Adryheat
sterilizeristwotothreetimeslighter
thananequivalentsteamsystem.
Becausethedryheatsterilizercanbe
riggedinplaceasmodules,thereare
considerablylessriggingchallenges
andcosts.Thedryheatsterilizerdoes
notneedtobepitmounted.
100% focused forced-air convectiontechnology.*PatentPending
About the Company
ThermalProductSolutionsdesignsandmanufacturessterilizers, industrialandlaboratoryovensandfurnaces,aswellasenvironmental temperaturecyclingandstabilitytestchambers.
Features and Benefits� Greenoperationwithlowertotalenergyconsumption
� Economicalcost
� Flexibleinstallationandcustomizationoptions
� Validatedsterilizationcyclesforassuredresults
� Energyefficientelectricalheatingsystem
� Easytousecontrols
� PrecisionFloTMFullfocusedairflow
� HEPAFilters
� Dataacquisitioncapabilities
� Panelizeddesign
Features and Benefits� Greenoperationwithlowertotalenergyconsumption
� Lowertotalcostofownership
� Flexibleinstallationoptions
� Flexibledesignallowscustomizationtosuiteveryapplication
� Validatedsterilizationcycles
� Fitsintosmallspacesandthrough42"x84"doorways
� Modulardesignforeaseofinstallation
� Easytousecontrols
Features and Benefits� Greenoperationwithlowertotalenergyconsumption
� Economicalcost
� Flexibleinstallationandcustomizationoptions
� Validatedsterilizationcyclesforassuredresults
� Easytousecontrolsandaccesstocontainers
� ConditioningunitcanbeusedwithmultiplePODs
� Modulardesignallowsforsimplerearranging
� Perfectforchangestationsterilization
Superior Results. Superior Controller.
Advantages of Dry Heat vs. Steam
Dry Heat Sterilizer New Steam Autoclave
Volume(CUFT) 139 139
Footprint(SQFT) 34.3 Sterilizer48.5Pit91.2
MinimumDimensionofParts(IN) 31.5 62.4
Utilities ElectricPower Steam,coldwater,drain,pit,electric,compressedair
WaterUsage(GAL) 0 700
CostPerCycle(Calculated) HalfofAutoclave ****
Measured Energy Consumption–Dry Heat
300 ° F Soak: 60 Minutes SteriDry™Stage Time (min) Power (kW) Energy (kWH) Cost ($)
RampUp 20 61 20.3 $2.64
Soak 60 12 11.7 $1.53
Cool 100 4 5.4 $0.83
Total 180 37.4 $4.99
� Multifunctionprogrammablecontroller
� Colortouchscreen
� Real-timedatawithrecipesetupandstorage
� SCADAcompliant
USER EXAMPLE:
Sterilizer Design Possibilities:� Proofofconceptandproofofprocess
� Developmentoftestplatformsandprototypeunits
� Optimizingproductionprocesses
� Pharmaceuticalprocessresearchandtesting
� Customprocesscontrolstosolvemanufacturingchallenges
Our SteriDry™ engineers are always
heretohelpyoudesignandimplement
our standard or custom sterilizers to
meet your project’s specific needs, no
matterhowdemanding.
Scanwithyoursmartphonetoseemoreaboutourdryheatsterilizers.
thermalproductsolutions.com
Gruenberg, Blue M, Tenney MailingAddress:P.O.Box150|WhiteDeer,PA17887-0150|USAPhone:(570)538-7200|Fax:(570)538-7380PhysicalAddress:2821OldRoute15|NewColumbia,[email protected] and Product Information are subject to change without notice.