gs-sys gold standard® calibration system (us & metric) · 2019. 1. 26. · standard®...

3
Interface Force Measurements Ltd. Wellington Business Park. Dukes Ride. Crowthorne. Berkshire. Phone 01344 776666. Fax 01344 774765. Web interface.uk.com. E-mail [email protected] Datasheet GS-SYS v3.2 05-17-2018 Page 1 of 3 FEATURES AND BENEFITS Capacies from 25K, 55K, & 100K lbf (110, 250, & 450 kN) SCB1 signal condioning board with very low nonlinearity specificaon (<0.003% FS) Less than 0.04% RDG uncertainty Fully automated system will reduce calibraon me by 50% to 90% Automated tensions and compression calibraon runs can be completed in less than 5 minutes 4-post design provides superior stability throughout the calibraon Innovave fixturing allows for tension and compression calibraon without changing setup 12 inches of clearance between posts allows for easy load cell installaon and removal Accurate and reliable load control achieved by proprietary load feedback design Tesng and reporng per ASTM E74, ISO 376, and EN100002-3 standards Automacally produces standard reports, graphs, and performance parameter calculaons Ability to customize reports and graphs Automacally archives data The Interface Gold Standard® Calibraon System using the Interface Gold or Planum Standard® Load Cells ensures a metrology system of the highest accuracy and lowest uncertainty available. The Gold Standard® Calibraon System includes: 25K, 55K, or 100K lbf (110, 250, or 450 kN) load frame Integrated control and measurement system Integrated computer system with Interface Gold Standard® Calibraon Soſtware One set of thread adapters for inial set-up and use Addional opons include: Interface Gold or Planum Standard® reference load cells Addional input channels for mulple bridge load cells or transducers with high level outputs HRBSC high performance resoluon signal condioning board with N/C <0.001% FS Special threads and calibraon adapters CX Series Precision mV/V transfer standard for system calibraon On-site training GS E74 soſtware for high level inputs GS E74 soſtware for system calibraons (Transducer and display as a system) Hinged Safety Shield (Load cells accessible from front and leſt side) Load points can be preset as required per your test specificaons The ICS-202 Gold Standard® Calibraon Soſtware ICS- 202 Gold Standard® Calibraon Soſtware will provide exact load output at specific load points Calibraon results from other runs can be compared, measured, and displayed with current run results GS-SYS GOLD STANDARD® CALIBRATION SYSTEM (US & METRIC) SOFTWARE STANDARD CONFIGURATION Model GS-SYS (shown)

Upload: others

Post on 18-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GS-SYS GOLD STANDARD® CALIBRATION SYSTEM (US & METRIC) · 2019. 1. 26. · Standard® Calibration Software • One set of thread adapters for initial set-up and use Additional options

Interface Force Measurements Ltd. Wellington Business Park. Dukes Ride. Crowthorne. Berkshire.Phone 01344 776666. Fax 01344 774765. Web interface.uk.com. E-mail [email protected]

Data

shee

t GS-

SYS

v3.2

05-

17-2

018

Page 1 of 3

FEATURES AND BENEFITS• Capacities from 25K, 55K, & 100K lbf (110, 250, & 450

kN)• SCB1 signal conditioning board with very low

nonlinearity specification (<0.003% FS)• Less than 0.04% RDG uncertainty• Fully automated system will reduce calibration time by

50% to 90%• Automated tensions and compression calibration runs

can be completed in less than 5 minutes• 4-post design provides superior stability throughout

the calibration• Innovative fixturing allows for tension and

compression calibration without changing setup• 12 inches of clearance between posts allows for easy

load cell installation and removal• Accurate and reliable load control achieved by

proprietary load feedback design• Testing and reporting per ASTM E74, ISO 376, and

EN100002-3 standards• Automatically produces standard reports, graphs, and

performance parameter calculations• Ability to customize reports and graphs• Automatically archives data

The Interface Gold Standard® Calibration System using the Interface Gold or Platinum Standard® Load Cells ensures a metrology system of the highest accuracy and lowest uncertainty available.

The Gold Standard® Calibration System includes:• 25K, 55K, or 100K lbf (110, 250, or 450 kN) load frame• Integrated control and measurement system• Integrated computer system with Interface Gold

Standard® Calibration Software• One set of thread adapters for initial set-up and use

Additional options include:• Interface Gold or Platinum Standard® reference load

cells• Additional input channels for multiple bridge load

cells or transducers with high level outputs• HRBSC high performance resolution signal

conditioning board with N/C <0.001% FS• Special threads and calibration adapters• CX Series Precision mV/V transfer standard for system

calibration• On-site training• GS E74 software for high level inputs• GS E74 software for system calibrations (Transducer

and display as a system)• Hinged Safety Shield (Load cells accessible from front

and left side)

• Load points can be preset as required per your test specifications

• The ICS-202 Gold Standard® Calibration Software ICS-202 Gold Standard® Calibration Software will provide exact load output at specific load points

• Calibration results from other runs can be compared, measured, and displayed with current run results

GS-SYS GOLD STANDARD® CALIBRATION SYSTEM (US & METRIC)

SOFTWARE

STANDARD CONFIGURATION

Model GS-SYS (shown)

Page 2: GS-SYS GOLD STANDARD® CALIBRATION SYSTEM (US & METRIC) · 2019. 1. 26. · Standard® Calibration Software • One set of thread adapters for initial set-up and use Additional options

Interface Force Measurements Ltd. Wellington Business Park. Dukes Ride. Crowthorne. Berkshire.Phone 01344 776666. Fax 01344 774765. Web interface.uk.com. E-mail [email protected]

Data

shee

t GS-

SYS

v3.2

05-

17-2

018

Page 2 of 3

DIMENSIONS

FRONT VIEW

TOP VIEW

A B

SIDE VIEW

See Drawing

CAPICITY

lbf kN

25K, 55K, 100K 110, 250, 450

in mm

1 30.0 762

2 81.0 2057

3 36.5 927

4 28.2 716

5 58.6 1488

6 34.0 864

7 19.0 483

8 12.5 318

9 24.4 MIN / 30.4 MAX 620 MIN / 772 MAX

10 1.75-12 UN 2A x 1.80 1.75-12 UN 2A x 45.7

11 1.75-12 UN 2B x 2.0 1.75-12 UN 2B x 51

4

5

7

6

2

3

1

8 9

10

11

GS-SYS GOLD STANDARD® CALIBRATION SYSTEM (US & METRIC)

Access Panel

Access Panel

Access Panel

Page 3: GS-SYS GOLD STANDARD® CALIBRATION SYSTEM (US & METRIC) · 2019. 1. 26. · Standard® Calibration Software • One set of thread adapters for initial set-up and use Additional options

Interface Force Measurements Ltd. Wellington Business Park. Dukes Ride. Crowthorne. Berkshire.Phone 01344 776666. Fax 01344 774765. Web interface.uk.com. E-mail [email protected]

Data

shee

t GS-

SYS

v3.3

05-

18-2

018

Page 3 of 3

SPECIFICATIONS

LOAD FRAME

Capacitylbf 25K, 55K, 100K

kN 110, 250, 450

Weightlbs 2200

kg 997.9

Type Four Column, Dual Action Hydraulic

Load Cell Test Type Compression or Tension

Horizontal Clearancein 12.5

mm 317.5

Vertical Clearancein 24.4 to 30.4

mm 619.8 to 772.2

Piston Strokein 6.0

mm 152.4

Top Swivel Thread 1.75-12 Male

Bottom Actuator Thread 1.75-12 Female

Position Sensor LVDT

Zero Control Automatic Return

Slack Adaptor Rangein ± 0.25

mm ± 6.35

Thread Adaptors Base Set Included

HYDRAULIC SYSTEM

Oil CapacityUS gal 10

L 37.85

Oil Type Mobile DTE25 or Equivalent

Oil Over-temperature Automatic Cut-Off

Low Oil Level Automatic Cut-Off Indicator

CONTROLS

Speed Control Automatic

Speed Selection Configurable

Controller PID

USER INTERFACE

Control Interface Industrial Computer

Software Interface Gold Standard®

Reports User Configurable

Test Reports Available ASTM E74, ISO 376 or Custom

Shunt Calibration Automatic or Manual

Curve Fit Least Square Method

Calibration History Compare Data with Past Results

CALIBRATION

Uncertainty - %RDG Less than 0.04 Uncertainty

Ranges Dependent on Gold Standard® Load Cell

Overload Protection User Configurable

Automatic Load Points User Configurable

Load Measurement Range - % 1 to 100 of Load Frame Capacity

A/D Calibration Standard Included

REQUIREMENTS

Power Requirements - VAC Hz A CCT 208/240, Single Phase, 50/60, 20

GS-SYS GOLD STANDARD® CALIBRATION SYSTEM (US & METRIC)

SHIPPING INFORMATION

Crate Dimensions and Weight

Dimensions - W x H x Din 72 x 90 x 48

mm 1828.8 x 2286 x 1219.2

Weightlbs 2500

kg 1133.981

Includes tilt/shock sensors

Fork lift access