guideline-huawei 3g dbs3900 (rru) deployment scenario_xl project
DESCRIPTION
TELECOMTRANSCRIPT
GUIDELINE HUAWEI 3G DBS3900 (RRU)
Deployment Scenario
Scenario for 3G with RRU
1. 3G RRU with AMP30H Rack scenario - For 3G Standalone
- For 3G 1on 1, where 2G existing not use BTS3900 series
2. 3G RRU with Common BBU scenario (Hybrid) - For 3G 1on1 where 2G already use BTS3900 series
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Scenario 1 3G RRU with AMP30H Rack
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
1. 3G RRU with AMP30H Rack scenario
Required space
APM30H Rack
Optic CPRI cable (Connect to WBBP)
RRU Power cable (connect to DCDU-12B)
Technical Specification
Material Dimension
(Height x Width x Depth)
Weight
APM30H 700mm x 600mm x
480mm < 76.5 Kg
RRU3839 400mm x 300mm
100mm 14 Kg
This scenario can be used on : 1. 3G Standalone site where no 2G existing 2. 3G 1on1 site where 2G existing doesn't have
any BTS3900 series By this scenario, 3G RRU system will use APM30H to put BBU3900 with WMPT & WBBP board inserted. APM30H already include with DCDU-12B which ports are support for RRU power cables size (4-6 mm2). (see DCDU-12B detail here) There for, RRU power cable can be connected directly to DCDU-12B on APM30H, and only need 1 MCB 80A-100A on Rectifier side.
BBU 3900
Detail material spec, see here
NOTE: Always order RRU Grounding Bar. For detail material, see here
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
SAP Material # for 3G RRU with AMP30H Rack
SAP # SAP Description Qty Unit Material contain with :
2505433 CABINET:DBS3900 WCDMA,S222 RRU3839 2X60W 1 SET
3 pcs RRU 3839 2100MHz 2x60W
1 pcs APM30
1 pcs BBU3900
1 pcs WMPT
1 pcs WBBPd (384/384)
1. DBS3900 system with Package Material (3 sectors)
2. Additional WBBPd (as required configuration)
3. Grounding for RRU
SAP # SAP Description Qty Unit Material contain with :
2136026 KIT,GROUNDING:BAR,FOR FOR TOWER 1 SET ·1 pcs Grounding Bar with
accessories
SAP # SAP Description Qty Unit Material contain with :
2389476 BOARD:BASEBAND PROCESSING UNIT IN UMTS B … EA 1 pcs WBBP board
(CE: 384 UL/384 DL)
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Scenario 2 3G RRU with Common BBU
(Hybrid)
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Required space
Example : Existing BTS3900A (2G)
2. 3G RRU with Common BBU scenario (Hybrid)
Optic CPRI cable (Connect to WBBP)
RRU Power cable (connect to DCDU-12B)
Technical Specification
Material Dimension
(Height x Width x Depth)
Weight
RRU3839 400mm x 300mm
100mm 14 Kg
This scenario can be used on : 1. 3G 1on1 where 2G existing already have
BTS3900 series. WMPT & WBBP for 3G system will be inserted to BBU3900 of existing 2G system. BTS3900/L/A are using different DCDU type (DCDU-03C or DCDU-12C), and not support for RRU Power cable size (4-6 mm2). There are 2 solution for this issue: 1. Add new DCDU-12B on existing
BTS3900/L/A , and use 1 MCB 80A - 100A on rectifier side.
2. RRU power cables connect directly to rectifier, and use 1 MCB 32A per RRU
Detail material spec, see here
NOTE: Always order RRU Grounding Bar. For detail material, see here Guideline-Huawei 3G DBS3900 (RRU)
deployment scenario
SAP Material # 3G RRU with Common BBU scenario (Hybrid)
1. DBS3900 system with Partial Material
2. Additional WBBPd (as required configuration)
3. Grounding for RRU
SAP # SAP Description Qty Unit Material contain with :
2136026 KIT,GROUNDING:BAR,FOR FOR TOWER 1 SET · 1 pcs Grounding Bar with
accessories
SAP # SAP Description Qty Unit Material contain with :
2389476 BOARD:BASEBAND PROCESSING UNIT IN UMTS B … EA 1 pcs WBBP board
(CE: 384 UL/384 DL)
SAP # SAP Description Qty Unit Material contain with :
2505569 MODULE: SINGLE BLADE RRU 3839 2100M U2 (2x60W, DC-48V, Multimode)
1 EA 1 pcs RRU 3839
2505144 BOARD: WCDMA MAIN CONTROL UNIT (WMPT) 1 EA 1 pcs WMPT
2389476 BOARD:BASEBAND PROCESSING UNIT IN UMTS B 1 EA 1 pcs WBBPd
Note: always reserve as number of sector
4. DCDU-12B for RRU
SAP # SAP Description Qty Unit Material contain with :
2506757 BOARD:DCDU-12B FOR DBS3900 (DC POWER,DISTRIBUTION UNIT 12B)
1 EA 1 pcs DCDU-12B
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
APPENDIX 1 Detail Specification
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Appendix 1a. APM30H Detail Specification
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Appendix 1b. RRU3839 Detail Specification
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Appendix 1b. RRU3839 Detail Specification (cont.)
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
APPENDIX 2 DCDU (DC power Distribution Unit)
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
DCDU-12B for RRU3839
DCDU type DBS3900 for optical system: - Use DCDU-12 for connect RRU power cable
- Different port type & size compared to DCDU for MRFU
- Higher max-load (30A for each RRU)
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
DCDU Type on BTS3900/L/A
On BTS3900 version B: • Use DCDU-03C • Only support for connect
MRFU/WRFU power cables • Not support for High Power RU
(MRFUd/WRFUe)
On BTS3900 version D: • Use DCDU-12C • Support for high power RU
(MRFUd/WRFUd/WRFUe) power cables
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
APPENDIX 3 RRU Grounding Bar Material &
Installation
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Grounding Bar for RRU
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Material package:
SAP # SAP Description Qty Unit Material contain with :
2136026 KIT,GROUNDING:BAR,FOR FOR TOWER 1 SET · 1 pcs Grounding Bar with accessories
Grounding Bar - Painting
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Process Silver Painting Grounding Bar
Grounding Bar - Installation
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Connection Isolator Grounding Bar to Tray
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Grounding Bar - Installation
Connection Isolator Grounding Bar to Tray
Guideline-Huawei 3G DBS3900 (RRU) deployment scenario
Grounding Bar - Installation
Connection Tiger nail to Vertical Grounding