HAND in HAND

HIGHER and HIGHER

Haier Air conditioner

Cooperation – AIRCON For EuropeFor Europe

Page 2: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

HFU-09H03/R2(DB) HFU-12H03/R2(DB)HSU-09H03/R2(DB) HSU-12H03/R2(DB)

Indoor unitIndoor unit

Power/HealthPower/Health timertimer OperateOperate

Page 3: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

HSU-09HS03/R2(DB) HSU-12HS03/R2(DB)

Indoor UnitIndoor Unit

CoolCoolHeatHeatOperateOperate

Page 4: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Malfunction Codes� H &HT & HS��1�

*■ � �Indoor fan motor malfunction

1**� � ■Ambient temp sensor fault

****

AutoRecover

**

Twinklingtimes of outdoor LED 2

3

2

Malfunction codes

Outdoor Unit

Indoor Unit

*� � ■Exhaust temperature sensor

*� � �Defrosting temperature sensor fault

� � �Heat-exchange thermister anomaly

� ■ ■Room-temperature sensor malfunction

Power Timer operateOperate Heat Cool

Content

Explanation �□bright �flashing ■turn-off * Represents there is this functionExplanation �□bright �flashing ■turn-off * Represents there is this function

Page 5: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Malfunction Codes � H&HT & HS� �2�

*� � �High work-intense protection

7 only for outdoor**� � �EEPROM error

AutoRecover

Twinklingtimes of outdoor LED 2

Outdoor Unit

Indoor Unit

Malfunction codes

Content Power Timer OperateOperate Heat Cool

10or13*� ■ �Anomaly of compressor Running

14*� � ■AC electricity protection

*

4

5or6

*■ � ■Overheat protection for exhaust temperature

*■ ■ �Communication fault

between the indoor and outdoor units

Page 6: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (1)

**� ■ ■Room-temperature sensor malfunction

AutoRecover

Malfunction codesOutdoor

UnitIndoor UnitPower Timer operate

operate Heat CoolContent

Countermeasure Flow Chart:Countermeasure Flow Chart:Check whether Terminals CN4(CN1 for HT) on the indoor mainboard contact well.

Pull out the terminals on the indoor mainboard and reinsert them.

NONO

Pull the sensor out of the mainboard, and measure the value of resistance between its two jumpers as well as the temperature at the temperature sensing head. Check the specifications of the sensor to decide whether the sensor is damaged.

Replace with a new sensor

YESYES Sensor damagedSensor

damaged

Malfunction unsolved

Malfunction unsolved

Sensor all right

Sensor all right

Replace with a new indoor mainboard.

Page 7: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (2)

**� � �Heat-exchange sensor malfunction

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codes

Content Power Timer operateoperate Heat Cool

Countermeasure Flow Chart:Countermeasure Flow Chart:Check whether Terminals CN4(CN1 for HT) on the indoor mainboard contact well.

Pull out the terminals on the indoor mainboard and reinsert them.

NONO

Pull the sensor out of the mainboard, and measure the value of resistance between its two jumpers as well as the temperature at the temperature sensing head. Check the specifications of the sensor to decide whether the sensor is damaged.

Replace with a new sensor

YESYES Sensor damagedSensor

damaged

Malfunction unsolved

Malfunction unsolved

Sensor all right

Sensor all right

Replace with a new indoor mainboard.

Page 8: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (3)

**� � �Frost-removing temperature sensor fault

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codes

Content Power Timer operateoperate Heat Cool

Countermeasure Flow Chart:Countermeasure Flow Chart:Check whether Terminal CN10 on the outdoor mainboard contact well.

Pull out the terminals on the outdoor mainboard and reinsert them.

NONO

Pull the sensor out of the mainboard, and measure the value of resistance between its two jumpers as well as the temperature at the temperature sensing head. Check the specifications of the sensor to decide whether the sensor is damaged.

Replace with a new sensor

YESYES Sensor damagedSensor

damaged

Malfunction unsolved

Malfunction unsolved

Sensor all right

Sensor all right

Replace with a new outdoor mainboard.

With the malfunction, LED2 on the outdoor mainboard blinks twice at frequency of 1 Hz and interval of 2 seconds or so.

Page 9: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (4)

**� � ■Exhaust temperature sensor

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codes

Content Power Timer operateoperate Heat Cool

Countermeasure Flow Chart:Countermeasure Flow Chart:Check whether Terminal CN11 on the outdoor mainboard contact well.

Pull out the terminals on the outdoor mainboard and reinsert them.

NONO

Pull the sensor out of the mainboard, and measure the value of resistance between its two jumpers as well as the temperature at the temperature sensing head. Check the specifications of the sensor to decide whether the sensor is damaged.

Replace with a new sensor

YESYES Sensor damagedSensor

damaged

Malfunction unsolved

Malfunction unsolved

Sensor all right

Sensor all right

Replace with a new outdoor mainboard.

With the malfunction, LED2 on the outdoor mainboard blinks three times at frequency of 1 Hz and interval of 2 seconds or so.

Page 10: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (5)

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codes

Content Power Timer operateoperate Heat Cool

**� � ■Ambient temp sensor fault

Countermeasure Flow Chart:Countermeasure Flow Chart:With the malfunction, LED2 on the outdoor mainboard blinks once at frequency of 1 Hz and interval of 2 seconds or so.

Check whether Terminal CN9 on the outdoor mainboard contact well.

Pull out the terminals on the outdoor mainboard and reinsert them.

NONO

Pull the sensor out of the mainboard, and measure the resistance between its two jumpers as well as the temperature at the temperature sensing head. Check the specifications of the sensor to decide whether the sensor is damaged.

Replace with a new sensor

YESYES Sensor damagedSensor

damaged

Malfunction unsolved

Malfunction unsolved

Sensor all right

Sensor all right

Replace with a new outdoor mainboard.

Page 11: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Mechanism of Sensor Malfunctions

The A/D circuit of sensor is as follows:The A/D circuit of sensor is as follows:

PORTR1

1K

R220K

C1

4.7uF/25V

R3R?

+5V

C1102

Page 12: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (6-1)Auto

Recover

Outdoor Unit

Indoor Unit

Malfunction codesContent Power Timer operate

operate Heat Cool

* *■ ■ �Communication fault between the indoor and outdoor units

Countermeasure Flow Chart:Countermeasure Flow Chart:

YESYES

NONOConnect to the power supply, and turn it on with the remote controller to check whether it starts up normally.

1. If starting up normally, the outdoor mainboard needs dewetting;2. If starting up normally, but malfunction occurs again after a while, the outdoor mainboard needs dedusting.

Check whether the linking cable between the indoor and outdoor units is well connected and whether its core wires are well insulated.

Check the status of LED1 on the indoor mainboard.

See next page.�TO BE CONTINUED�

NONO

1.Reconnect the linking cable;2. Replace the linking cable with new one.

YESYES OFFOFF

NONO

1. If LED1 keeps on, the indoor mainboard is damaged;2. If LED1 blinks interruptedly, both the indoor and outdoor mainboards may be damaged. Judge as follow:

� measure the voltage between Jumpers 3 and 4 of IC12 on the indoor mainboard with a multimeter. If the voltage is of a constant value of 0VDC or 5VDC, the indoor mainboard is damaged;

� measure the voltage between Jumpers 3 and 4 of IC12 on the indoor mainboard with a multimeter. If the voltage varies between 0 and 3VDC, the outdoor mainboard is damaged.

Page 13: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (6-2)

Countermeasure Flow Chart�CONTINUE��Countermeasure Flow Chart�CONTINUE��

LED1 of indoor mainboard is OFF.

Trouble shooting process:1. Test the outdoor power supply (230VAC and +310VDC) with a multimeter. If 230VAC is available but 310DC not, the SPDU�IPDU, HT�module is damaged, replace it with a new one. If both 230VAC and 310DC are available, go forward to step 2.2. Measure the voltage across Jumpers 1 and 4 of Terminal CN7 on the outdoor mainboard with a multimeter. If +12DC is not available, the SPDU�IPDU, HT�module is damaged, replace it with a new one. If +12VDC is available, go forward to step 3.3. Within two minutes after the machine is supplied with power and turn on, measure the AC voltage between positions 1 and 3 on the terminal of outdoor unit with a multimeter. If the value varies between 0 and 80 VAC, the outdoor mainboard is damaged, replace it with a new one. If the value is constant at about 30V, the indoor mainboard is damaged, replace it with a new one.

AutoRecov

er

Outdoor Unit

Indoor Unit

Malfunction codes

Content Power Timer operateoperate Heat Cool

* *■ ■ �Communication fault between the indoor and outdoor units

Page 14: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

R16

10K

C6102

C7102

IC2

R15

330

R182.2K

R14 1M

C5103

R132.2K

D6

1N4007D5

1N4007

R12

2W6.8K1

N

1

COM

R17

10K

+5

124

56

INDOOR UNIT

IC1

LED1

DQ12SD1781K

receive

send

+5V

TLP371 R1 820SEND

R2

1M

C1 0.001UF

R96.8K

R106.8K

R116.8K

D4 1N4007

R81M

C4

22UF/400VDC

D3

1N4007

D2

1N4007

C30.01UF

R61K

R510K

R710K

D1 1N4007

OUTDOOR UNIT

1

COM

1

N

1

LPOWER

IC4

R310K

R4

10K C20.01UF

+5V

RECEIVE

Page 15: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (7)

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codesContent Power Timer operate

operate Heat Cool

*� ■ �Anomaly of compressor Running

Countermeasure Flow Chart�Countermeasure Flow Chart�Check the status of LED2 on the maindboard of outdoor unit and the running condition of outdoor unit within 3 minutes after startup.

Within 3 minutes after the machine is supplied with power and turned on with the remote controller, the outdoor unit stops shortly after startup, and the compressor will start up again 10 seconds after the machine stops. The above process repeats again and again. 1. The wiring of compressor is incorrect or the connection is poor;2. The compressor is damaged.

CASE1CASE1

At the stopped state, LED2 blinks � 1Hz � for several times, and after pause of 2 seconds or so, it blinks for the same times again.

LED2 blinking for 10 times indicates that the compressor might be damaged.

CASE2CASE2

LED2 blinking for 13 times indicates that Module SPDU might be damaged.

Page 16: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (8)

AutoRecov

er

Outdoor Unit

Indoor Unit

Malfunction codesContent Power Timer operate

operate Heat Cool

*■ � ■Overheat protection for exhaust temperature

Countermeasure Flow Chart�Countermeasure Flow Chart�

Electrify the machine again and turn it on with the remote controller, then measure the temperature at the exhaust temperature sensor of the compressor on the outdoor unit.

If the temperature exceeds 115� shortly after the machine starts up, the cryogen may have been leaked during installation, or there may be leakage in the piping system, or there may be other causes to make the exhaust temperature too high.

CASE1CASE1

Malfunctions occur after running for some time even though the measured temperature is below 115�.

Pull out the exhaust sensor and measure its resistance at standard temperatures. If the results deviate much from those in the resistance-temperature table, the sensor is damaged and needs replacing.

CASE2CASE2

Pull out the exhaust sensor and measure its resistance at standard temperatures. If the results do not deviate or deviate a little from those in the resistance-temperature table, the outdoor mainboard is damaged and needs replacing.

CASE1CASE1

CASE2CASE2

Page 17: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (9)

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codesContent Power Timer operate

operate Heat Cool

*� � ■AC electricity protection

Countermeasure Flow Chart�Countermeasure Flow Chart�

Electrify the machine again and turn it on with the remote controller, then observe its operation.

If malfunctions are reported before or upon the compressor being started up, Module SPDU is damaged and needs replacing.

CASE1CASE1

The compressor is started normally, but malfunctions are reported after it has run for some time.

If the power supply is in order, the system may have been over or under charged with gas, which can be judged through the pressure of the measuring system.

CASE2CASE2

Check the power supply. If the voltage is too low or too high, the machine is not damaged. It is the power supply that needs to be changed or improved.

CASE2CASE2

CASE1CASE1

With this malfunction, LED2 on the outdoor mainboard blinks at a frequency of 1Hz and an interval of about 2 seconds for 14 times.

Page 18: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (11)

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codesContent Power Timer operate

operate Heat Cool

*� � �High work-intense protection

Countermeasure Flow Chart�Countermeasure Flow Chart�

Electrify the machine again and turn it on with the remote controller, then observe its operation.

If the wind temperature is below 50�and the malfunction is reported after the machine has run for some time, check whether the sensor or the temperature monitoring circuit of the indoor mainboard is in order. See countermeasures for sensor troubles.

CASE1CASE1

If both the sensor and the temperature monitoring circuit of the indoor mainboard are in order, shoot the trouble as follows:1. Check whether the indoor unit blows poorly due to blocked filters or poor condition of the fan. If yes, clean the filters or reinstall the fan. If not, go forward to Case 2.2. Measure the pressure of the system. If the pressure is too high, the system is over charged with gas, otherwise go forward to Case 3.3. Find other causes to make the temperature of coil pipes on the indoor unit too high and take according measures.

CASE2CASE2

Page 19: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (12)

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codesContent Power Timer operate

operate Heat Cool

* *� � �EEPROM error

Countermeasure Flow Chart�Countermeasure Flow Chart�

Check whether LED2 on the outdoor unit blinks 7 times at an interval of 2 seconds.

The indoor mainboard is damaged. Replace it with a new one.

NONO

The outdoor mainboard is damaged. Replace it with a new one. If the malfunction still exists, it is possible that the indoor mainboard is also damaged, and needs replacing with a new one.

YESYES

Page 20: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor Europe

Countermeasures for Frequent Malfunctions (13)

AutoRecover

Outdoor Unit

Indoor Unit

Malfunction codes

Content Power Timer operateoperate Heat Cool

*■ � �Indoor fan motor malfunction

Countermeasure Flow Chart�Countermeasure Flow Chart�

Check whether Terminal CN8 (CN6 for HT) on the indoor mainboard is well inserted.

Pull out and reinsert the terminals.

NONO

Electrify the machine again and turn it on in the Cool state with the remote controller. Measure the voltage between the middle wire and the black side wire of Terminal CN8 on the indoor mainboard.

YESYES

Malfunction unsolved

Malfunction unsolved

YESYES

NONO

If there is variation of voltage, the indoor mainboard is damaged and needs replacing.

If there is no variation of voltage, the motor of the indoor unit is damaged and needs replacing.

Page 21: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

Cooperation – AIRCON For EuropeFor EuropeCountermeasures for Other Frequent

Malfunctions (14)With the machine electrified, the remote controller cannot start itWith the machine electrified, the remote controller cannot start it

Countermeasure Flow Chart�Countermeasure Flow Chart�Open the front cover of the indoor unit and press the emergency button once.

If the air conditioner is started normally, check whether the battery in the remote controller is powerless, whether the remote controller is damaged and whether the signal receiver works well.

CASE1CASE1

If there is no response after the emergency button is pressed down, shoot the trouble as follows:1. Check whether there is voltage of 230VAC between Positions 1 and 2 on the terminal of the indoor unit. If not, check the power supply and the damage of the power cables. If yes, go forward to Step 2.2. Check the FUSE of the indoor mainboard. If burned out or broken, replace the fuse, or go forward to Step 3.3. Check with a multimeter whether the voltage between the two ulterior positions on Terminal CN1-2 of the indoor mainboard is 10VAC�14VAC. If no, the transformer needs replacing. If yes, the indoor mainboard might be damaged and needs replacing.

CASE2CASE2

If the remote controller resets itself frequently and the air conditioner cannot receive signals from the controller, the batteries in the remote controller need replacing.

Page 22: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

The figure on the right shows the electric diagram for the indoor unit of DC products with Model H Economical Series.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16 17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32P04/INT24

P05/INT25

P06/INT26

P61

P07/INT27

P60

/RST

X0

X1

VSS

P37/BZ/PPG

P36/INT12

P35/INT11

P34/T0/INT10

P33/EC

C P32/UI/SI

P31/UO/SO

P30/UCK/SCK

P50/PWM

P70

P71

P72

P40/AN0

P41/AN1

P42/AN2

P43/AN3

P00/-INT20/AN4

P01/-INT21/AN5

P02/-INT22/AN6

P03/-INT23/AN7

VCC

FLZ

BUZ1

R2

1K

R1220

+12V

R410K

R5 10K

¸şŔë×Ó

»»Đ·ç

ĘŇÍâͨѶĘäłö

ąýÁăĽě˛â

Ëőʱ/×ÔĽě

Ó¦Ľ±żŞąŘ

R1210KCN10

TEST

+5V

SW1

+5V

+5V

C4 104

OSC1

8M

123

CN8 R710K

R6

2.2K C6

102

+5V

PG·´Ŕˇ

ŇŁżŘ˝ÓĘŐ

12345678 9

10111213141516

12345

CN6

+12V

ABCD

123

SW2R102.2K+5VR9 2.2K

×Ô¶ŻÔËĐĐ

»úĐÍѡÔń

C10 104

C7

102

12345

678

+5VC11104

IC2

IC3

IC1+5V

TIMERRUN

GND

+5V

REC

1234

CN4+5V

R133.3K

R1420K

C12102

C13

102

ROOMPIPE

R1510K

·ç»úĘäłöĂć°ĺѡÔń

µĽ°ĺѡÔń

ĘŇÍâͨѶĘäČë

A

B

C

D

·äĂůĆ÷

TXO

TXI

FLZPGO

C1102

C2103

C5103

C9103

R321K

E8

4.7U

R1910K

R1810KR20

1K

Q39013

R1710K

E4

470uF/16V

C15104

Vout 3G

ND

2Vin1

IC47805

FUSE1

T3.15A 250VACC20

0.47uF/275VAC

1

2

3

4

IN4007

ZE1S14K350

E3

1000uF/35V

C14

104

+5V+12VD5

IN4007

CN14AC-L

AC-N

D1D2

D3 D4

+5V

RL1

12345

CN9

FLZ

+12V

FLZ

FRED

FWHITE

C18

223/630VAC

C19

1.2uF/450VAC

AC-L

C

PGO

AC-N

12 3

4

1234

56

TLP521

TLP371

C17104

R28

330K

R272.2K

LED1

D7

IN4007

D6

IN4007

R29

2W6.8K

R262.2K

R25

10K

C16

102

+5V

ĘŇÍâͨѶĘäČë

+5V

R30

330Q2

9013

ĘŇÍâͨѶĘäłö

R232.2K

R22

1K

R242.2K

PGÇý¶Ż

+12VIC5

MOC3021

T1

T2

G 3

IC6

BT136/600E

6

4

1

2 R21

510

IC8

IC7

R31

1K

C21104

C22

104

123

SW3R392.2K

1234567

CN2-1

µçÔ´G

µçÔ´R

R34470

R36470

R37

100

R38

10K

R351K

C23

102

12

CN5

COM

220-N

123

CN1-1

123

CN1-2

CN11

CN12

E74.7U

+5

R11

2.2K

Page 23: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

The figure on the right shows the electric diagram for the indoor unit of DC products with Smart Eye Series.

R110K

R162W/47K

R36

10k

C37

102

C31104

C30102

R172W/47K

C24102

C38102

12345

CN4

1 2 3 4 5

CN3

13 2

CX14M

Ď°ڷ粽˝řµç»ú

×ó°Ú·ç˛˝˝řµç»ú ÓҰڷ粽˝řµç»ú

Ăć°ĺͨѶĘäČë

ĽŻÖĐżŘÖĆ˝ÓĘŐĽŻÖĐżŘÖĆĘäłö

·çËŮ·´Ŕˇ

R26

10k

R2410K

Ăć°ĺͨѶĘäłö

¸şŔë×Ó

ąýÁă

1

220VL

1

220VN

FUSET3.15A

C15

0.1uF/275V EMI1

20mH

1

2

3

4

C1222U/450V

D10HER103

C7470U/16V

C8

220U/16V

+5

Vin1

GN

D2

Vout 3IC7

7805C18104D2

D1 D3

D41N4007

1N4007 1N4007

1N4007

R19

3.6/3W

C13472/1KV

R9

47K/2W

D8

1N4007

żŞąŘµçÔ´

ZE1S14K350

R6

27

C17

102

IC10

521

PTC41

IRQ2

RST3

PTF0/TACH24

PTF1/TACH35

PTF2/TACH26

PTF3/TACH37

PTF4/TACH08

NC9

PTF710

PTF5/TBCH111

PTF612

PTE0/TXD13

PTE1/RXD14

PTE2/TACH015

PTE3/TACH116

PTE4/SS17

PTE5/MISO18

PTE6/MOSI19

PTE7/SPSCK20

VSS21

VDD22

PTG0/KBD023

PTG1/KBD124

PTG2/KBD225

PA026

PA127

PA228

PA329

PA430

PA531

PA632 PA7 33ATB0/ATD0 34ATB1/ATD1 35ATB2/ATD2 36ATB3/ATD3 37ATB4/ATD4 38ATB5/ATD5 39ATB6/ATD6 40ATB7/ATD7 41PTD0 42PTD1 43VDDAREF 44AVSS/VREFL 45PTD2 46PTD3 47PTH0/KBD3 48PTH1/KBD4 49PTD4/TBCLK 50PTD5 51PTD6/TACLK 52PTD7 53VREFH 54VDDA 55VSSA 56CGMXFC 57OSC2 58OSC1 59PTC0 60PTC1 61PTC2/MCLK 62PTC3 63PTC5 64

AB32

IC1

908AB32

+5

R3510k

R2

1K

R2710K

+5

C32102

R3133K

R4

1K

R2810K

+5

R3

10KDQ3

2SD1781K

DQ22SD1781KÔ¶łĚͨĐĹ

12

CN7

IC12

TLP371

R39

330

R372.2K

R41 1M

C23103

R402.2K

D5

1N4007D6

1N4007

R18

2W6.8K1

220V-N

1

P3

R38

10K

+5

124

56

ĘŇÄÚÍâͨĐĹ

IC11

TLP521

12

CN2

LED1

123

CN6

CON3

+5

·ç»ú·´Ŕˇ

C33103

+5V

R3051K

R29 1K

+5

IC8

TLP3526

123

CN14C29

2UF 450V

+12V1

220VL

R8680/ 0.25WÄÚ·ç»ú

RC1

0.01U*120/300V

PGĘäłö

12

CN8

+5

C41103

´Ĺ±Ł»¤żŞąŘ R2010K

34 5

6781

2

IC5

24C01A

+5

C2

4.7UF/50V

C1

4.7UF/50V

1234

CN1

R22 1K

R21 1K

R453.3K 1%

R4420K 1%

RL2JQ1a-12V

+5

+12

12345

CN9

S1

+5R3210K

+5

R43

10K

PGĘäłö

ĘŇÍâͨĐĹ˝ÓĘŐ

ĘŇÍâͨĐĹ·˘ËÍ

×ĎÍâĎß

¸şŔë×ÓĽÓŃő/»»Đ·ç

ĘŇÎÂĹĚąÜ

×ÔĽě/Ëőʱ

TXDRXD

C28104

DQ52SD1781K

R25

1K

R231K

C34103

C36

102

C35

102

DQ42SD1781K

+5

Ăć°ĺͨĐĹ

SDASCL

D12UF4007

D9

PKMUR4200224

R7

27

C16

102

C9

470U/25V

+12

C6100U/16V

123456789 10 11 12 13 14 15 16

IC2 2003

123456789 10 11 12 13 14 15 16

IC4 2003

123456789 10 11 12 13 14 15 16

IC3 2003

´Ĺ±Ł»¤żŞąŘ12345

CN11

1 2 3 4 5

CN12

CD

AB

CD

BA

CD

BA

C

D

BA

Éϰڷ粽˝řµç»ú

+12 +12

+12

ą¦Âʼ̵çĆ÷

+12

+12+12

+12

C4100u/16v

C27104/50V

+5

C3100u/16v

C26

104/50V

+5

C5100u/16v

C25

104/50V

+5

C22104

C20104

1

220VL

P8

P1

P6

R11

500K

R13

500K

(şě)

(şě)

R46 22K R474.7K

+5

R3410K

ą¦Âʼ̵çĆ÷

ĽÓŃő

¸şŔë×Ó

IC9

Q817C

C14222/300VAC

R42150

R11

5.6K

C39

104/100V

D111N4148

32

1

IC6 TOP222Y

R12

15/1\4W

´ĹÖé

T1

C11

47U/50V

R5 10K

C40104/100V

D1310V/0.5W

»»Đ·çR3310K

R10

1K

+12

Q1

2SB1182

1

CN15-1

1

CN15-2

+12

R131.5K

LED2

ĽÓŃő/»»Đ·ç

·çËŮѡÔń

R48

10K SW

+5

·çËŮѡÔń

R4910K

Page 24: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

The figure on the right shows the electric diagram for the outdoor unit of DC products with both Model H Economical and Smart Eye Series.

Page 25: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

The figure on the right shows the wiring diagram for the indoor unit of DC products with Model H Economical Series.

Page 26: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

The figure on the right shows the wiring diagram for the indoor unit of DC products with Smart Eye Series.

I NDO

OR P

CB

Page 27: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

The figure on the right shows the wiring diagram for the outdoor unit of DC products with Model H Economical Series. B BLACK

BL BLUE

R RED

W WHI TE

Y/ G YELLOW

OR ORANGE

/ GREENGR GRAY

BL

CN11

CN10

CN9

SPDU

CN10

OR

2

1

The capaci t or r et ai ns hi gh vol t age even af t er t he pl ug- of f . For your saf et y, be sur e t o wai t at l east 5 mi nut es. af t er pl ug of f and use a t est er t o conf i r m t he vol t age bet ween connect or CN1 and CN2 i s l ess t han DC 10V bef or e st ar t ser vi ci ng.

DON' T TOUCH CAPACI TOR, EVEN AFTER PLUG- OFF ( DANGER OF ELECTRI C SHOCK)

WARNINGCAUTION

WI RI NG DI AGRAM OF OUTDOOR UNI T

I NDUCTANCE

COMPRESSOR

4- WAY VALVE

FAN MOTOR

FAN MOTOR

TERMI NAL BLOCK

TO I NDOOR UNI T

AMBI ENT TEMP. SENSOR

TEMP. SENSOR OF HEAT

COMP. TEMP. SENSOR

FAN MOTOR ˘ Ů I S FOR °9000BTU ±UNI TSŁ »

FAN MOTOR ˘ Ú I S FOR °12000BTU ±UNI TSŁ »

25A/250VAC

FUSE

CAPACI TOR PCB BOARD

Page 28: Haier Air conditioner - clima-services.com modeli.pdf · HAND in HAND HIGHER and HIGHER Haier Air conditioner Cooperation – AIRCON For EuropeFor Europe

The figure on the right shows the wiring diagram for the outdoor unit of DC products with Smart Eye Series.

2 5A

IPDU

OUTDOOR PCB