hamilton arc system - insatech · • upside-down mounting possible • monitoring of all sensor...
TRANSCRIPT
Sensing Solutions that Empower and Propel
HAMILTON ARC SYSTEM
The true power of the HAMILTON ARC familyHAMILTON has delivered quality products to laboratories for more than 50 years, including products such as syringes, laboratory devices, automation platforms and sensors.
In the world of process analytics, HAMILTON is known for sensors (pH, oxygen, redox, and conductivity), and for its first-class choice of process armatures, completed with their selection of process connectors.
HAMILTON ARC revolutionizes the integration of sensors by rethinking communication between sensors, end users and process control systems. The functionality of a traditional transmitter has been replaced by a microprocessor within the sensor. ARC sensors bypass the transmitter and communicate directly to the control system. Sensors are available in all standard pH, dissolved oxygen and conductivity formats.
ARC Vital: Eliminate the cost of the transmitter and get more reliable readings
For users in established facilities, ARC sensors can communicate without the use of a transmitter with 4-20 mA devices or digitally with a computer. In this area the advantage of the ARC system is in lab calibration with ARC View Handheld, retained records, and the proven quality and accuracy of HAMILTON sensors. The 4-20 mA signal is more stable and reliable than the low currents or voltages in classical oxygen, conductivity or pH measurement.
ARC Versa: In lab pre-calibrations, sensor management with ARC View Handheld and wireless communication option
Combine cost savings and reliability of ARC Vital with the convenience of ARC View Handheld and ARC Wi. The ARC View Handheld device facilitates in-lab pre-calibration, configuration of the HAMILTON ARC sensors, and sensor management. Wired or wireless communication will make handling and maintenance of the sensors and process control more reliable, simple and efficient.
ARC Vision: Digital signal transmission and wireless monitoring of multiple sensorsFor new facilities and installations the ARC sensors are truly revolutionary. In digital mode several ARC sensors can run and be maintained in parallel. Wired or wireless communication will make installation, handling and maintenance of the sensors and process control more reliable, simple and efficient. ARC View Handheld enables wireless, handheld, local monitoring of all sensors in process as well as in-lab calibration of sensors prior to installation into the process.
The bridge between process parameter and process controlThree ARC concepts meet customer requirements from established research and pilot labs to new production facilities and installations:
HAMILTON’s ARC Vital, ARC Versa, and ARC Vision systems offer an optimal solution for every use case.
– 2 –
HAMILTON ARC System
– 3 –
Sensing Solutions that Empower and Propel
Advanced solution for new installations that are running a digital network. The ARC sensors are connected through Modbus to the PLC, and the ARC View Handheld provides onsite monitoring and calibration
· Provides the premium digital solution for new levels of performance.
· Eliminates downtime, increases process safety and accuracy.
Products: ARC sensors (digital mode), ARC View Handheld, and ARC Wi Sensor Adapter.
CUTTING-EDGE TECHNOLOGY
SIMPLICITY AND QUALITY MULTIPLE CONNECTIVITY
ARC VitalPremium quality sensors solution for applications where the PLC is in close proximity to the sensor and no local display is required.
· Saves cost of ownership.
· Optimizes your analog system through delivering directly from the sensor a robust signal interface.
Products: ARC sensors (4-20mA mode) and ARC View Handheld for in lab calibration.
Which ARCare you?
ARC VersaOnline sensor management solution for applications where the sensor is positioned far from the PLC and local reading would be enabled through a wireless connection to the ARC View Handheld.
· Empowers you to get the most out of the combination of analog and digital technologies at your disposal.
· Gives onsite personnel the ability to stay mobile as they monitor data directly from the sensors.
Products: ARC sensors (4-20mA mode), ARC View Handheld, and ARC Wi Sensor Adapter.
4 -
20 m
A
PLC
Mod
bus
PLC
4 -
20 m
A
PLC
ARC Vision
• PHERMLYTEreferenceelectrolytefactoryprepressurizedforaclog-freediaphragm and minimized diaphragm potentials
• HighperformanceHPCOATRAMICdiaphragm
• EVEREF-FReferencecartridgeforsilver-freeelectrolytes
• Poisonresistant“PHI“pHglass
• Monitoringofallsensorfunctions,statusofthesensorquality(glassresistance,reference resistance)
• Excellentlinearity.Independantofcableconditionsandlength
• Suitableforsteamsterilization,autoclavingandCIP
• AllpartsincontactwithmediaareFDA-compliant
• Easytocleanduetotheforward-facing,flush arrangementofelectrodes,EHEDGcertifiedwithHygienicSocket
• Monitoringofallsensorfunctions,statusofthesensorquality(cellconstant)
• Transmitterless-directdigitaland/oranalogsignalbyprovenVP8.0connectorhead.
• PG13.5processthreadconnection.
• On-lineandinlabpre-calibration,autorecognitionofthecalibrationstandard(internallystoreddataforcalibrationstandards).
• ConfigurableusingtheRS485interfacewithPC,ARCViewHandheldorbyusingtheModbusRTUprotocolfromtheprocesscontrolsystem.
• Savesallprocessrelevantinformation:sensoridentityandcalibrationdata,operatinghours,cleaningandsterilizationcycles,sensorquality,errorsandwarnings.
– 4 –
HAMILTON ARC Sensors
Optical Oxygen Sensor: VISIFERM DO ARC
• Precisemeasurementoptics,stableupto130°C
• Doesnotrequireelectrolyteandpolarization
• Temperature-resistantelectronicsbuiltintoa12mmshaft
• Easily replaceable sensor cap containing the sensing element
• Monitoring of all sensor functions and status of the replaceable sensor cap
• Suitableforsteamsterilization,autoclavingandCIP
Technical Data
Range of measurement: 0.05 - 300% air saturationDetectionlimit: 0.01%-volResponsetimet98%: <30sat25°C,fromairtonitrogenOxygen consumption: NoneRequired flow: NoneOperationtemperature: -10-130°C;thesensorprovides
noDOreadingabove80°CPressurerange: 0-12barMeasurement principle: Oxygen dependant luminescenceMediumcontactedmaterials: Stainlesssteel316L/DIN1.4435 FDA-approvedSiliconeandEPDMSurface quality of steel: Ra = 0.4 μm (N5)Interface: Configurable4-20mAinterface(DOor
temperature),digitalRS485ModbusRTUinterface
Conductivity Sensor: Conducell 4USF ARCRangeofmeasurement: 1-500000μS/cmExpectedcellconstant: c≈0.36cm-1
Operationtemperature: 0-130°CPressure range: 0 - 20 barTemperature sensor: YesMeasurement principle: Four pole contactingMediumcontactedmaterials: Stainlesssteel316L/DIN1.4435 FDA-approvedPEEK FDA-approvedEPDMSurface quality of steel: Ra = 0.4 μm (N5)Interface: 2x 4-20 mA interface (conductivity and
temperature),digitalRS485ModbusRTUInterface
pH Sensor: Easyferm Plus ARC
Rangeofmeasurement: pH0-14Zero point: 0 ± 20 mVOperationtemperature: 0-130°CPressurerange: 0-6barTemperature sensor: YesMeasurement principle: Potential measured against referenceShaftmaterial: GlassMembraneglass: HAMILTONtype“PHI”glassO-ringmaterial: FDA-approvedEPDMElectrolyte: Pressurized PHERMLYTEDiaphragmmaterial: HPCOATRAMICInterface: 2x 4-20 mA interface (pH and
temperature) , digital RS485 ModbusRTUInterface
Unique Features of all ARC Sensors
• Suitedforapplicationsinbio-technology,pharmaceutical industry, food industry and beverage industry
• CleanabilitytestedandcertifiedaccordingtoEHEDGcriteria
• BiocompatibiltytestedandcertifiedbyMDT
• Odorlessandtastelessgelelectrolyte(testedbyTÜVRheinland)
• Small sensitivity todisturbancesandeasily calibratedbecauseofHAMILTON“HB”pHglass
• Monitoringofallsensorfunctions,statusofthesensorquality(glassresistance,reference resistance)
pH Sensor: Easyferm Food ARC
pH Sensor: Polilyte Plus ARC
• POLISOLVE PLUS reference electrolyte allows highly reproducible and stablemeasurements over long periods of time
• Minimaldiffusionpotential
• 2SINGLEPOREs fordirect contactbetweenPOLISOLVEPLUSelectrolyteandmedium
• HAMILTON“H“ pH glass, stable for long periods plus a patented referencesystem
• Upside-downmountingpossible
• Monitoringofallsensorfunctions,statusofthesensorquality(glassresistance,reference resistance)
pH Sensor: pHeasy ARC
• ARCempowersfullyintegratedaccuracymonitoring
• Extends service intervals and increases reliability of pH measurementapplications
• Upside-downmountingpossible
• 2 SINGLE POREs for clog-free contact between measurement medium andPOLISOLVE electrolyte
• Monitoringofallsensorfunctions,statusofthesensorquality(glassresistance,reference resistance, Checkref potential)
Rangeofmeasurement: pH0-14Zero point: 0 ± 20 mVOperationtemperature: 0-130°CPressurerange: 0-6barTemperature sensor: YesMeasurement principle: Potential measured against referenceShaftmaterial: GlassMembraneglass: HAMILTONtype“PHI”glassO-ring material: FPMElectrolyte: POLISOLVEDiaphragmmaterial: SINGLEPOREInterface: 2x 4-20 mA interface (pH and
temperature),digitalRS485ModbusRTUInterface
– 5 –
HAMILTON ARC Sensors
Rangeofmeasurement: pH0-14Zero point: 0 ± 20 mVOperationtemperature: 0-130°CPressurerange: 0-6barTemperature sensor: YesMeasurement principle: Potential measured against referenceShaftmaterial: GlassMembraneglass: HAMILTONtype“HB”glassO-ringmaterial: FDA-approvedEPDMElectrolyte: PressurizedFOODLYTEDiaphragmmaterial: HPCOATRAMICInterface: 2x 4-20 mA interface (pH and
temperature),digitalRS485ModbusRTUInterface
Rangeofmeasurement: pH0-14Zero point: 0 ± 20 mVOperationtemperature: 0-130°CPressurerange: 0-6barTemperature sensor: YesMeasurement principle: Potential measured against referenceShaftmaterial: GlassMembraneglass: HAMILTONtype“H”glassO-ring material: FPMElectrolyte: POLISOLVEPLUSDiaphragmmaterial: SINGLEPOREInterface: 2x 4-20 mA interface (pH and
temperature),digitalRS485ModbusRTUInterface
Technical Data
ARC View Handheld
ARC Wi Sensor Adapter
–6–
HAMILTONARCDevices
Permissibleoperatingtemp.: 5-45°CMax.transmittingpower: +0dBmMax.datatransmissionrate: 256kbpsCommunicationprotocol: ModbusRTUFrequencyrange: 2.45GHz(IEEE802.15.4)Max.rangeinopenarea: ~100mMax. range in process environment: ~20 mDimensions(WxDxH): 140x35x85mmWeight: 340 gPower supply: •OnArcViewDockingwithplug-inpowersupplyunit: 100-240V~/50-60Hz•Batterycontinuousoperation: 9hProtectionRating: IP 67 (exceptARCView Dock, power
adapter and sensor cable)USBinterface: OnARCViewDockPowersupplyunitwithplugadaptersforEU,GB,USA,AUS
Technical Data
This device empowers the operator to monitor measurement values, calibrate ARCsensorsandconfigurevariousparameters.ThestandardversionofARCViewHandheld can communicate with up to 30 ARC sensors over wireless channel paralleltotheprocesscontrolsystem’smaininterface.WithARCViewDocktheARC View Handheld is connected over cable to a single ARC sensor and can be usedasalaboratorydesktopcalibration,configurationandmonitoringtool.
• On-line wireless sensor monitoring (up to 30 HAMILTON ARC sensors)
• Displaysensordata
• Sensor calibration
• Sensorconfiguration
• Visualization of the sensor status
• Datamanagement
This wireless adapter is mounted between the VP head of an ARC sensor and the VP sensor cable. The ARC Wi provides the wireless communication between the ARC sensor and ARC View Handheld unit.
• ARCWiisplug&playforeachandeveryARCsensortype
• Configuration-freeinstallation
• AnalogsensorsignalsarebypassedthroughtheARCWiSensorAdapter
• Routingfunctionsforthedigitalsignalsbetweenwirelessandwiredconnections(PLC)
• Visualindicationofanactivewirelessconnectionandsensorfailure
Permissibleoperatingtemp. 5-80°CMax.transmittingpower: +0dBmMax.datatransmissionrate: 256kbpsCommunicationprotocol: ModbusRTUFrequencyrange: 2.45GHz(IEEE802.15.4)Max.rangeinopenarea: ~100mMax. range in process environment: ~20 mDimensions(WxDxH): 75x30x70mmWeight: 110gPower supply: With VP sensor cable
ARCViewHandheldDock
ARC View Handheld
Technical Data
Product name Order numberEasyfermPlusARC120 242091
Easyferm Plus ARC 225 242 092
Easyferm Plus ARC 325 242 093
Easyferm Plus ARC 425 242 094
PolilytePlusARC120 242111
Polilyte Plus ARC 225 242112
Polilyte Plus ARC 325 242113
Polilyte Plus ARC 425 242114
EasyfermFoodARC120 242120
Easyferm Food ARC 225 242121
Easyferm Food ARC 325 242122
Easyferm Food ARC 425 242123
pHeasyARC120 242154
pHeasy ARC 225 242155
pHeasy ARC 325 242156
pHeasy ARC 425 242157
Conducell4USFARC120 242159
Conducell4USFARC225 242160
Conducell4USFARC325 242161
Conducell4USFARC425 242162
VisifermDOARC120 242163
VisifermDOARC225 242164
VisifermDOARC325 242165
VisifermDOARC425 242166
ARC View Handheld Package 242180
ARC Wi Sensor Adapter 242170
–7–
Ordering Information
includes:
ARC View Handheld•
ARCViewHandheldDock•
ARCCableVP8•
ARC Memory Stick•
Power Adapter•
ARC View Handheld Package
P/N:691069/0103-2010
Your HAMILTON representative:
http://www.hamiltoncompany.com
Europe, Africa, Asia: [email protected] America, South America, Pacific Rim:
HAMILTON Bonaduz AGViaCrusch8CH-7402Bonaduz,SwitzerlandToll-Free:00800-660-660-60Telephone:+41-81-660-60-60Fax:[email protected]
HAMILTON Company4970EnergyWayReno,Nevada89502USAToll-Free:800-648-5950Telephone:+1-775-858-3000Fax:[email protected]
HAMILTON Quality Products:Laboratory ElectrodesDURACAL™pHBuffersConductivity SensorsConductivity StandardsDissolvedOxygenSensorsArmatures for SensorsMICROLITER™-SyringesGASTIGHT®-SyringesInstrument SyringesSoftGrip™-PipettesMiniature ValvesBioLevitatorDeCapper
Laboratory Automation for:DrugDiscoveryGenomicsProteomicsForensicsInVitroDiagnostics