PageContentsHan-Com® Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.02Han® K 8/24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.04Han® K 4/4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.06Han® K 4/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.08Han® K 6/12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.10Han® K 6/36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.12Han® K 12/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.14Han® K 4/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.16Han® K 6/6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.18Han® K 8/0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05.20Assembly instructions Han® K 4/4 / Han® K 6/12 / Han® K 6/6 / Han® K 8/0 05.22
05.02
HanCom
Han-Com® Summary
Size Description
10 B
Power areaSignal area
Han® K 8/2416 A / 230/400 V10 A / 160 VPage 05.04
Han® K 4/463 A / 690 V16 A / 230 VPage 05.06
16 B
Power areaSignal area
Han® K 4/0, 4/280 A / 830 V16 A / 400 VPage 05.08
Han® K 6/1240 A / 690 V10 A / 230/400 VPage 05.10
Han® K 6/3640 A / 690 V10 A / 160 VPage 05.12
Han® K 12/240 A / 690 V10 A / 250 VPage 05.14
24 B
Power areaSignal area
Han® K 4/880 A / 400 V16 A / 400 VPage 05.16
Han® K 6/6100 A / 690 V16 A / 400 VPage 05.18
Han® K 8/0100 A / 690 VPage 05.20
32 B suitable for 2 inserts of size 16 B
48 B suitable for 2 inserts of size 24 B
05.03
HanCom
Han-Com® Summary
Summary
Type
Technical characteristics Suitable Hoods/HousingsPower area Signal area
Numberof
contactsA Termination
Numberof
contactsA Termination Size
Han® K 4/0 4+PE 80 830 screw — — — — 16 B, 32 BHan® K 4/2 4+PE 80 830 screw 2 16 400 screw 16 B, 32 BHan® K 4/4 4+PE 63 690 axial screw 4 16 250 cage clamp 10 BHan® K 4/8 4+PE 80 400 screw 8 16 400 screw 24 B, 48 BHan® K 6/6 6+PE 100 690 axial screw 6 16 400 screw 24 B, 48 BHan® K 6/12 6+PE 40 690 axial screw 12 10 230/400 screw 16 B, 32 BHan® K 6/36 6+PE 40 690 crimp 36 10 160 crimp 16 B, 32 BHan® K 8/0 8+PE 100 690 axial screw — — — — 24 B, 48 BHan® K 8/24 8+PE 16 230/400 crimp 24 10 160 crimp 10 BHan® K 12/2 12+PE 40 690 crimp 2 10 250 crimp 16 B, 32 B
Han® K 6/12Han® Industrial connectors Han®K Series Han® K / Han-Com®6 Number of power contacts12 Number of signal contacts
Han® K connectors from 1 to ... (power area)from 11 to... (signal area)ExceptionsHan® K 4/8 and Han® K 8/24 from 1 to ... (consecutively)Han® K 12/2 from 1 to 12 (power area)with „a“ and „b“ (signal area)
Comment for usersFor the combination of several circuits in one cable and/or e.g. one connector the following standards are valid:
VDE 0100-410/06.2007 § 411.1.3.2 and EN 60 204/06.2007 § 13.1.3
AccessoriesCrimping tools chapter 99Cable clamps chapter 95Coding of hoods/housings chapter 95Label acc. to CSA-approval chapter 95Han-Snap® chapter 11PCB adapter chapter 95
05.04
HanCom
Han® K 8/24
Features-
nector® and Han D® contacts
Removal of power contacts (Han E®)
relevant hole of the contact until it reaches the bottom
Removal of signal contacts (Han D®)Description see removal tool chapter 99
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Operating
current
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals , ,
InsertsNumber of contacts 8 / 24 + PEElectrical dataacc. to EN 61 984Power area 16 A 230/400 V 4 kV 3Rated current 16 ARated voltage conductor - ground 230 VRated voltage conductor - conductor 400 VRated impulse voltage 4 kVPollution degree 3Pollution degree 2 also 10 A 250 V 4 kV 2
Signal area 10 A 160 V 2.5 kV 3Rated current 10 ARated voltage 160 VRated impulse voltage 2.5 kVPollution degree 3Rated voltage
10Material PolyamideLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm Ag - hard-gold plated 2 µm Au over 3 µm NiCrimp terminal
Signal contactsMaterial copper alloySurface - hard-silver plated 3 µm Ag - hard-gold plated 2 µm Au over 3 µm NiCrimp terminal
Hoods/Housings see chapter 31
05.05
HanCom
Han® K 8/24 Size 10 B 400/160V 16/10A
Stock items in bold type
Number of contacts8/24 + Part number
Crimp terminalOrder crimp contactsseparately
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 38 032 3001" "https://b2b.harting.com/ebusiness/en/09 38 032 3101"
Crimp contactsPower contactssilver plated
0.50.75
11.52.54
"https://b2b.harting.com/ebusiness/en/09 33 000 6121"
"https://b2b.harting.com/ebusiness/en/09 33 000 6114"
"https://b2b.harting.com/ebusiness/en/09 33 000 6105"
"https://b2b.harting.com/ebusiness/en/09 33 000 6104"
"https://b2b.harting.com/ebusiness/en/09 33 000 6102"
"https://b2b.harting.com/ebusiness/en/09 33 000 6107"
"https://b2b.harting.com/ebusiness/en/09 33 000 6220"
"https://b2b.harting.com/ebusiness/en/09 33 000 6214"
"https://b2b.harting.com/ebusiness/en/09 33 000 6205"
"https://b2b.harting.com/ebusiness/en/09 33 000 6204"
"https://b2b.harting.com/ebusiness/en/09 33 000 6202"
"https://b2b.harting.com/ebusiness/en/09 33 000 6207"
Operating contact Relay contact
Strippinglength
no groove 1 groove* 1 groove 2 grooves 3 grooves no groove
0.50.75
11.52.5
4
7.5 mm7.5 mm7.5 mm7.5 mm7.5 mm7.5 mm
* on the back crimp collar
gold plated 0.50.75
11.52.54
"https://b2b.harting.com/ebusiness/en/09 33 000 6122"
"https://b2b.harting.com/ebusiness/en/09 33 000 6115"
"https://b2b.harting.com/ebusiness/en/09 33 000 6118"
"https://b2b.harting.com/ebusiness/en/09 33 000 6116"
"https://b2b.harting.com/ebusiness/en/09 33 000 6123"
"https://b2b.harting.com/ebusiness/en/09 33 000 6119"
"https://b2b.harting.com/ebusiness/en/09 33 000 6222"
"https://b2b.harting.com/ebusiness/en/09 33 000 6215"
"https://b2b.harting.com/ebusiness/en/09 33 000 6218"
"https://b2b.harting.com/ebusiness/en/09 33 000 6216"
"https://b2b.harting.com/ebusiness/en/09 33 000 6223"
"https://b2b.harting.com/ebusiness/en/09 33 000 6221"
Relay contactssilver plated
0.75-11.52.5
"https://b2b.harting.com/ebusiness/en/09 33 000 6109"
"https://b2b.harting.com/ebusiness/en/09 33 000 6110"
"https://b2b.harting.com/ebusiness/en/09 33 000 6111"
Signal contactssilver plated
0.14-0.370.50.75
11.52.5
"https://b2b.harting.com/ebusiness/en/09 15 000 6104"
"https://b2b.harting.com/ebusiness/en/09 15 000 6103"
"https://b2b.harting.com/ebusiness/en/09 15 000 6105"
"https://b2b.harting.com/ebusiness/en/09 15 000 6102"
"https://b2b.harting.com/ebusiness/en/09 15 000 6101"
"https://b2b.harting.com/ebusiness/en/09 15 000 6106"
"https://b2b.harting.com/ebusiness/en/09 15 000 6204"
"https://b2b.harting.com/ebusiness/en/09 15 000 6203"
"https://b2b.harting.com/ebusiness/en/09 15 000 6205"
"https://b2b.harting.com/ebusiness/en/09 15 000 6202"
"https://b2b.harting.com/ebusiness/en/09 15 000 6201"
"https://b2b.harting.com/ebusiness/en/09 15 000 6206"
Stripping length0.14-0.37
0.50.75
11.52.5
0.91.11.3
1.451.752.25
8 mm8 mm8 mm8 mm8 mm6 mm
gold plated 0.14-0.370.50.75
11.52.5
"https://b2b.harting.com/ebusiness/en/09 15 000 6124"
"https://b2b.harting.com/ebusiness/en/09 15 000 6123"
"https://b2b.harting.com/ebusiness/en/09 15 000 6125"
"https://b2b.harting.com/ebusiness/en/09 15 000 6122"
"https://b2b.harting.com/ebusiness/en/09 15 000 6121"
"https://b2b.harting.com/ebusiness/en/09 15 000 6126"
"https://b2b.harting.com/ebusiness/en/09 15 000 6224"
"https://b2b.harting.com/ebusiness/en/09 15 000 6223"
"https://b2b.harting.com/ebusiness/en/09 15 000 6225"
"https://b2b.harting.com/ebusiness/en/09 15 000 6222"
"https://b2b.harting.com/ebusiness/en/09 15 000 6221"
"https://b2b.harting.com/ebusiness/en/09 15 000 6226"
F.O. contactsfor 1 mm
"https://b2b.harting.com/ebusiness/en/20 10 001 3211" "https://b2b.harting.com/ebusiness/en/20 10 001 3221"
05.06
HanCom
Han® K 4/4
Featuressame connector
power contacts
Assembly instructions see page 05.22
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals
InsertsNumber of contacts 4 / 4 + PEElectrical dataacc. to EN 61 984Power area 63 A 690 V 8 kV 3Rated current 63 ARated voltage 690 VRated impulse voltage 8 kVPollution degree 3Signal area 16 A 250 V 4 kV 3Rated current 16 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage
10Material polycarbonateLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm AgAxial screw termination
Max. insulation diameter
Tightening tourque 6 10 16 22Nm 2 3 4 4
Stripping length 6 10 16 22mm 11+1 11+1 11+1 13+1
Signal contactsMaterial copper alloySurface - hard-silver plated 3 µm AgCage clamp terminal
Stripping length 7 ... 9 mm
Hoods/Housings see chapter 31
05.07
HanCom
Han® K 4/4 Size 10 B 690/230 V 63/16 A
Stock items in bold type
Number of contacts4/4 + Part number
Han® K 4/4Axial screw terminal /Cage clamp terminal
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 38 008 2601" "https://b2b.harting.com/ebusiness/en/09 38 008 2701"
"https://b2b.harting.com/ebusiness/en/09 38 008 2602" "https://b2b.harting.com/ebusiness/en/09 38 008 2702"
"https://b2b.harting.com/ebusiness/en/09 38 008 2611"
"https://b2b.harting.com/ebusiness/en/09 38 008 2612"
for axial setscrew
adapter 1/4“ "https://b2b.harting.com/ebusiness/en/09 99 000 0375"
05.08
HanCom
Han® K 4/0, Han® K 4/2
Featuresconnector
® K 4/0In accordance with the appropriate regulations a wire-end sleeve has to be used at clamps without wire protection (see „Screw terminal“, chapter 00).
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals , ,
InsertsNumber of contacts 4 / 2 + PEElectrical dataacc. to EN 61 984Power area 80 A 830 V 8 kV 3Rated current 80 ARated voltage 830 VRated impulse voltage 8 kVPollution degree 3Pollution degree 2 also 80 A 1000 V 8 kV 2
Signal area 16 A 400 V 6 kV 3Rated current 16 ARated voltage 400 VRated impulse voltage 6 kVPollution degree 3Pollution degree 2 also 16 A 400/690 V 6 kV 2
Rated voltage10
Material polycarbonateLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm AgScrew terminal
Tightening tourque 1.5 2.5 4 6 10 16Nm 1.2 2 3 3 3 3
Stripping length 14 mmSignal contactsMaterial copper alloySurface - hard-silver plated 3 µm AgScrew terminal
Tightening tourque 0.5 NmStripping length 7.5 mm
Hoods/Housings see chapter 31
05.09
HanCom
Han K 4/0, Han® K 4/2 Size 16 B 830/400 V 80/16 A
Stock items in bold type
Number of contacts4/0, 4/2 + Part number
Han K 4/0, Han® K 4/2Screw terminal
1) Distance for contact max. 21 mm
Han K 4/0 Han® K 4/2Contact arrangement view from termination side
Han® K 4/2 "https://b2b.harting.com/ebusiness/en/09 38 006 2601" "https://b2b.harting.com/ebusiness/en/09 38 006 2701"
Han® K 4/0 "https://b2b.harting.com/ebusiness/en/09 38 006 2611" "https://b2b.harting.com/ebusiness/en/09 38 006 2711"
05.10
HanCom
Han® K 6/12
Featuresconnector
Assembly instructions see page 05.23
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals , ,
InsertsNumber of contacts 6 / 12 + PEElectrical dataacc. to EN 61 984Power area 40 A 690 V 8 kV 3Rated current 40 ARated voltage 690 VRated impulse voltage 8 kVPollution degree 3Signal area 10 A 230/400 V 4 kV 3Rated current 10 ARated voltage conductor - ground 230 VRated voltage conductor - conductor 400 VRated impulse voltage 4 kVPollution degree 3Rated voltage
10Material polycarbonateLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm AgAxial screw termination
Max. insulation diameter 6.1 mmTightening tourque 2.5 4 6 10
Nm 1.5 1.5 2 2Stripping length 2.5 4 6 10
mm 5+1 5+1 8+1 8+1
Signal contactsMaterial copper alloySurface - hard-silver plated 3 µm AgScrew terminal
Tightening tourque 0.5 NmStripping length 7.5 mm
Hoods/Housings see chapter 31
05.11
HanCom
Han® K 6/12 Size 16 B 690/400 V 40/10 A
Stock items in bold type
Number of contacts6/12 + Part number
Han® K 6/12Axial screw terminal /Screw terminal
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 38 018 2601" "https://b2b.harting.com/ebusiness/en/09 38 018 2701"
"https://b2b.harting.com/ebusiness/en/09 38 018 2602" "https://b2b.harting.com/ebusiness/en/09 38 018 2702"
for axial setscrew
adapter 1/4“ "https://b2b.harting.com/ebusiness/en/09 99 000 0369"
05.12
HanCom
Han® K 6/36
Featuresconnector
® C and Han D® contacts
Removal of power contacts (Han® C)Description see removal tool chapter 99
Removal of signal contacts (Han D®)Description see removal tool chapter 99
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals , ,
InsertsNumber of contacts 6 / 36 + PEElectrical dataacc. to EN 61 984Power area 40 A 690 V 8 kV 3Rated current 40 ARated voltage 690 VRated impulse voltage 8 kVPollution degree 3Signal area 10 A 160 V 2.5 kV 3Rated current 10 ARated voltage 160 VRated impulse voltage 2.5 kVPollution degree 3Pollution degree 2 also 10 A 250 V 4 kV 2
Rated voltage10
Material polycarbonateLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm Ag - hard-gold plated 2 µm Au over 3 µm NiCrimp terminal
Max. insulation diameter 5 mmSignal contactsMaterial copper alloySurface - hard-silver plated 3 µm Ag - hard-gold plated 2 µm Au over 3 µm NiCrimp terminal
Hoods/Housings see chapter 31
05.13
HanCom
Han® K 6/36 Size 16 B 690/160 V 40/10 A
Stock items in bold type
Number of contacts6/36 + Part number
Crimp terminalOrder crimp contacts separately
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 38 042 3001" "https://b2b.harting.com/ebusiness/en/09 38 042 3101"
Crimp contactsPower contactssilver plated
1.52.546
"https://b2b.harting.com/ebusiness/en/09 32 000 6104"
"https://b2b.harting.com/ebusiness/en/09 32 000 6105"
"https://b2b.harting.com/ebusiness/en/09 32 000 6107"
"https://b2b.harting.com/ebusiness/en/09 32 000 6108"
"https://b2b.harting.com/ebusiness/en/09 32 000 6204"
"https://b2b.harting.com/ebusiness/en/09 32 000 6205"
"https://b2b.harting.com/ebusiness/en/09 32 000 6207"
"https://b2b.harting.com/ebusiness/en/09 32 000 6208"
Stripping length1.52.5
46
1.752.252.853.5
9.5 mm9.5 mm9.5 mm9.5 mm
Signal contactssilver plated
0.14-0.370.50.75
11.52.5
"https://b2b.harting.com/ebusiness/en/09 15 000 6104"
"https://b2b.harting.com/ebusiness/en/09 15 000 6103"
"https://b2b.harting.com/ebusiness/en/09 15 000 6105"
"https://b2b.harting.com/ebusiness/en/09 15 000 6102"
"https://b2b.harting.com/ebusiness/en/09 15 000 6101"
"https://b2b.harting.com/ebusiness/en/09 15 000 6106"
"https://b2b.harting.com/ebusiness/en/09 15 000 6204"
"https://b2b.harting.com/ebusiness/en/09 15 000 6203"
"https://b2b.harting.com/ebusiness/en/09 15 000 6205"
"https://b2b.harting.com/ebusiness/en/09 15 000 6202"
"https://b2b.harting.com/ebusiness/en/09 15 000 6201"
"https://b2b.harting.com/ebusiness/en/09 15 000 6206"
Stripping length0.14-0.37
0.50.75
11.52.5
0.91.11.3
1.451.752.25
8 mm8 mm8 mm8 mm8 mm6 mm
gold plated 0.14-0.370.50.75
11.52.5
"https://b2b.harting.com/ebusiness/en/09 15 000 6124"
"https://b2b.harting.com/ebusiness/en/09 15 000 6123"
"https://b2b.harting.com/ebusiness/en/09 15 000 6125"
"https://b2b.harting.com/ebusiness/en/09 15 000 6122"
"https://b2b.harting.com/ebusiness/en/09 15 000 6121"
"https://b2b.harting.com/ebusiness/en/09 15 000 6126"
"https://b2b.harting.com/ebusiness/en/09 15 000 6224"
"https://b2b.harting.com/ebusiness/en/09 15 000 6223"
"https://b2b.harting.com/ebusiness/en/09 15 000 6225"
"https://b2b.harting.com/ebusiness/en/09 15 000 6222"
"https://b2b.harting.com/ebusiness/en/09 15 000 6221"
"https://b2b.harting.com/ebusiness/en/09 15 000 6226"
F.O. contactsfor 1 mm
"https://b2b.harting.com/ebusiness/en/20 10 001 3211" "https://b2b.harting.com/ebusiness/en/20 10 001 3221"
05.14
HanCom
Han® K 12/2
Featuresconnector
® C and Han D® contacts
Removal of power contacts (Han® C)Description see removal tool chapter 99
Removal of signal contacts (Han D®)Description see removal tool chapter 99
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals , ,
InsertsNumber of contacts 12 / 2 + PEElectrical dataacc. to EN 61 984Power area 40 A 690 V 8 kV 3Rated current 40 ARated voltage 690 VRated impulse voltage 8 kVPollution degree 3Signal area 10 A 250 V 4 kV 3Rated current 10 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage
10Material polycarbonateLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm Ag - hard-gold plated 2 µm Au over 3 µm NiCrimp terminal
Signal contactsMaterial copper alloySurface - hard-silver plated 3 µm Ag - hard-gold plated 2 µm Au over 3 µm NiCrimp terminal
Hoods/Housings see chapter 31
05.15
HanCom
Han® K 12/2 Size 16 B 690/250 V 40/10 A
Stock items in bold type
Number of contacts12/2 + Part number
Crimp terminalOrder crimp contacts separately
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 32 012 3001" "https://b2b.harting.com/ebusiness/en/09 32 012 3101"
Crimp contactsPower contactssilver plated
1.52.546
"https://b2b.harting.com/ebusiness/en/09 32 000 6104"
"https://b2b.harting.com/ebusiness/en/09 32 000 6105"
"https://b2b.harting.com/ebusiness/en/09 32 000 6107"
"https://b2b.harting.com/ebusiness/en/09 32 000 6108"
"https://b2b.harting.com/ebusiness/en/09 32 000 6204"
"https://b2b.harting.com/ebusiness/en/09 32 000 6205"
"https://b2b.harting.com/ebusiness/en/09 32 000 6207"
"https://b2b.harting.com/ebusiness/en/09 32 000 6208"
Stripping length1.52.5
46
1.752.252.853.5
9.5 mm9.5 mm9.5 mm9.5 mm
Signal contactssilver plated
0.14-0.370.50.75
11.52.5
"https://b2b.harting.com/ebusiness/en/09 15 000 6104"
"https://b2b.harting.com/ebusiness/en/09 15 000 6103"
"https://b2b.harting.com/ebusiness/en/09 15 000 6105"
"https://b2b.harting.com/ebusiness/en/09 15 000 6102"
"https://b2b.harting.com/ebusiness/en/09 15 000 6101"
"https://b2b.harting.com/ebusiness/en/09 15 000 6106"
"https://b2b.harting.com/ebusiness/en/09 15 000 6204"
"https://b2b.harting.com/ebusiness/en/09 15 000 6203"
"https://b2b.harting.com/ebusiness/en/09 15 000 6205"
"https://b2b.harting.com/ebusiness/en/09 15 000 6202"
"https://b2b.harting.com/ebusiness/en/09 15 000 6201"
"https://b2b.harting.com/ebusiness/en/09 15 000 6206"
Stripping length0.14-0.37
0.50.75
11.52.5
0.91.11.3
1.451.752.25
8 mm8 mm8 mm8 mm8 mm6 mm
gold plated 0.14-0.370.50.75
11.52.5
"https://b2b.harting.com/ebusiness/en/09 15 000 6124"
"https://b2b.harting.com/ebusiness/en/09 15 000 6123"
"https://b2b.harting.com/ebusiness/en/09 15 000 6125"
"https://b2b.harting.com/ebusiness/en/09 15 000 6122"
"https://b2b.harting.com/ebusiness/en/09 15 000 6121"
"https://b2b.harting.com/ebusiness/en/09 15 000 6126"
"https://b2b.harting.com/ebusiness/en/09 15 000 6224"
"https://b2b.harting.com/ebusiness/en/09 15 000 6223"
"https://b2b.harting.com/ebusiness/en/09 15 000 6225"
"https://b2b.harting.com/ebusiness/en/09 15 000 6222"
"https://b2b.harting.com/ebusiness/en/09 15 000 6221"
"https://b2b.harting.com/ebusiness/en/09 15 000 6226"
F.O. contactsfor 1 mm
"https://b2b.harting.com/ebusiness/en/20 10 001 3211" "https://b2b.harting.com/ebusiness/en/20 10 001 3221"
05.16
HanCom
Han® K 4/8
Featuresconnector
In accordance with the appropriate regulations a wire-end sleeve has to be used at clamps without wire protection (see „Screw terminal“, chapter 00).
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals , ,
InsertsNumber of contacts 4 / 8 + PEElectrical dataacc. to EN 61 984Power area 80 A 400 V 6 kV 3Rated current 80 ARated voltage 400 VRated impulse voltage 6 kVPollution degree 3Pollution degree 2 also 80 A 400/690 V 6 kV 2
Signal area 16 A 400 V 6 kV 3Rated current 16 ARated voltage 400 VRated impulse voltage 6 kVPollution degree 3Rated voltage
10Material PolyamideLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm AgScrew terminal
Tightening tourque 1.5 2.5 4 6 10 16Nm 1.2 2 3 3 3 3
Stripping length 14 mmSignal contactsMaterial copper alloySurface - hard-silver plated 3 µm AgScrew terminal
Tightening tourque 0.5 NmStripping length 7.5 mm
Hoods/Housings see chapter 31
05.17
HanCom
Han® K 4/8 Size 24 B 400/400 V 80/16 A
Stock items in bold type
Number of contacts4/8 + Part number
Han® K 4/8Screw terminal
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 38 012 2601" "https://b2b.harting.com/ebusiness/en/09 38 012 2701"
05.18
HanCom
Han® K 6/6
Features-
nector
Assembly instructions see page 05.24 Hoods/Housings see chapter 31
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals , ,
InsertsNumber of contacts 6 / 6 + PEElectrical dataacc. to EN 61 984Power area 100 A 690 V 8 kV 3Rated current 100 ARated voltage 690 VRated impulse voltage 8 kVPollution degree 3Pollution degree 2 also 100 A 1000 V 8 kV 2
Signal area 16 A 400 V 6 kV 3Rated current 16 ARated voltage 400 VRated impulse voltage 6 kVPollution degree 3Rated voltage Rated voltage acc. to CSA 600 V / 600 VRated current acc. to CSA 100 A / 15 A
10Material polycarbonateLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsPower contactsMaterial copper alloySurface - hard-silver plated 3 µm AgAxial screw termination
Max. insulation diameter 11.4 mmTightening tourque 16 25 35
Nm 6 7 8Stripping length 13±1 mmSignal contactsMaterial copper alloySurface - hard-silver plated 3 µm AgScrew terminal
Tightening tourque 0.5 NmStripping length 7.5 mm
05.19
HanCom
Han® K 6/6 Size 24 B 690/400 V 100/16 A
Stock items in bold type
Number of contacts6/6 + Part number
Han® K 6/6Axial screw terminal /Screw terminal
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 38 012 2651" "https://b2b.harting.com/ebusiness/en/09 38 012 2751"
for axial setscrew
with grip "https://b2b.harting.com/ebusiness/en/09 99 000 0363"
adapter 3/8“ "https://b2b.harting.com/ebusiness/en/09 99 000 0370"
05.20
HanCom
Han® K 8/0
Features
Assembly instructions see page 05.25
Current carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve
-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques according to DIN EN 60 512-5-2
Opera
ting cu
rrent
Ambient temperature
Technical characteristicsDIN EN 60 664-1DIN EN 61 984
Approvals
InsertsNumber of contacts 8 + PEElectrical dataacc. to EN 61 984Power area 100 A 690 V 8 kV 3Rated current 100 ARated voltage 690 VRated impulse voltage 8 kVPollution degree 3Pollution degree 2 also 100 A 1000 V 8 kV 2
Rated voltage
10Material polycarbonateLimiting temperatures -40 °C ... +125 °CMechanical working life
ContactsMaterial copper alloySurface - hard-silver plated 3 µm AgAxial screw termination
Max. insulation diameter 11.4 mmTightening tourque 10 16 25
Nm 6 6 7Stripping length 13±1 mm
Hoods/Housings see chapter 31
05.21
HanCom
Han® K 8/0 Size 24 B 690 V 100 A
Stock items in bold type
Number of contacts8/0 + Part number
Han® K 8/0Axial screw terminal
1) Distance for contact max. 21 mm
Contact arrangement view from termination side
"https://b2b.harting.com/ebusiness/en/09 38 008 2653" "https://b2b.harting.com/ebusiness/en/09 38 008 2753"
for axial setscrew
with grip "https://b2b.harting.com/ebusiness/en/09 99 000 0363"
adapter 3/8“ "https://b2b.harting.com/ebusiness/en/09 99 000 0370"
05.22
HanCom
Assembly instructions Han® K 4/4
Description Depiction Dimensions in mm
Step 1:Signal contacts:Push screwdriver (0.5 x 3.5) into rectangular chamber. Strip insulation from the wire with a length given on page 05.06 and insert the wire into the round contact chamber.Power contacts:Strip insulation from the wire with a length given on page 05.06 and insert the wire into with contact. Do not twist the strands of the wire.
l: Stripping length for signal contactsL: Stripping length for power contacts
Step 2:Signal contacts:Push screwdriver (0.5 x 3.5) out of rectangu-lar chamber.Power contacts:Hold the wire in position and tighten by a he-with a tightening torque given on page 05.06.
Step 3:Complete connection
The male insert is shown. The same method is applicable for female inserts.
05.23
HanCom
Assembly instructions Han® K 6/12
Description Depiction Dimensions in mm
Step 1:Signal contacts:Strip insulation from the wire with a length given on page 05.10 and insert the wire into the rectangular contact chamber.Power contacts:Strip insulation from the wire with a length given on page 05.10 and insert the wire into with contact. Do not twist the strands of the wire.
l: Stripping length for signal contactsL: Stripping length for power contacts
Step 2:Signal contacts:Tighten screw termination with screwdriver (0.5 x 3.5) with a tightening torque given on page 05.10.Power contacts:Hold the wire in position and tighten by a with a tightening torque given on page 05.10.
Step 3:Complete connection
The male insert is shown. The same method is applicable for female inserts.
05.24
HanCom
Assembly instructions Han® K 6/6
Description Depiction Dimensions in mm
Step 1:Signal contacts:Strip insulation from the wire with a length given on page 05.18 and insert the wire into the rectangular contact chamber.Power contacts:Strip insulation from the wire with a length given on page 05.18 and insert the wire into with contact. Do not twist the strands of the wire. l: Stripping length for signal contacts
L: Stripping length for power contacts
Step 2:Signal contacts:Tighten screw termination with screwdriver (0.5 x 3.5) with a tightening torque given on page 05.18.Power contacts:Hold the wire in position and tighten by a with a tightening torque given on page 05.18.
Step 3:Complete connection
The male insert is shown. The same method is applicable for female inserts.
05.25
HanCom
Assembly instructions Han® K 8/0
Description Depiction Dimensions in mm
Step 1:Strip insulation from the wire with a length given on page 05.20 and insert the wire into with contact. Do not twist the strands of the wire.
L: Stripping length for power contacts
Step 2:Hold the wire in position and tighten by a with a tightening torque given on page 05.20.
Step 3:Complete connection
The male insert is shown. The same method is applicable for female inserts.