hand rehabilitation glove

5
@ IJTSRD | Available Online @ www ISSN No: 245 Inte R Han Raja Vik 1 Professor, 2 Student, 1,2 M H New Nagpa ABSTRACT In this paper, we present the mechanism helpful for an individual to cope Rehabilitation exercises. Mechanism p will be useful for assisting human being Hand Rehabilitation. We propose to de soft wearable hand glove which comfo the human hand. One hand will be detection Glove which includes the Fle the other is the assistive hand used for p Rehabilitation exercises. Basically our d could be used for robotic orthosis. Keywords: Hand Rehabilitation; Flex S Detection Glove; Exoskeletal Glo Orthosis. I. INTRODUCTION From a purely physiological point of vie entirely engineered device comprised of muscles, and 32 joints [1]. The term robot is often used but seldo A robot may be broadly defined as a m in some way physically similar to a h performs a function similar to that pe human [2]. Hand Structures are made up of den tissue and the ability of this strong den tissue to glide in relation to one anoth for the functioning of the normal Hand motor impairment is the most comm found in the patients suffering from t w.ijtsrd.com | Volume – 2 | Issue – 5 | Jul-Aug 56 - 6470 | www.ijtsrd.com | Volum ernational Journal of Trend in Sc Research and Development (IJT International Open Access Journ nd Rehabilitation Glove kram Reddy 1 , Aliasgar Barodawala 2 H Saboo Siddik College of Engineering, Mumbai ada, Mazgaon, Mumbai, Maharashtra, India m which will be up with the proposed here g in case of the esign a pair of ortably fits on e the Motion ex Sensors and performing the designed glove Sensor; Motion ove; Robotic ew, the hand is f 27 bones, 24 om understood. machine that is human or that erformed by a nse connective nse connective her is essential d. Phalange al mon condition the Accidental fractures or neurological disa are lacking motor skills un physical therapy training in wh To perform various repetitiv original motor skills as that of The intended use of our me physiotherapy exercises to th met hand fracture and is in a exercises. In general, the receive motor action command The movements of the robotic moving the user’s fingers usi Bluetooth modules which is th in use. Bluetooth module pr meters (LOS). The project aims to design effective and an affordable pro hand for rehabilitation. The f control signals to the arm wire hand mimics the movement of II. BLOCK DIAGRAM The system consists of two s & the Slave Section. The Bloc is depicted in the Figure includes the Flex sensor transmitting ATmega328 alo HC-05 Bluetooth wireless m includes the Servo motors c ATmega328 along with receiv 2018 Page: 1392 me - 2 | Issue 5 cientific TSRD) nal i University, array. The patients who ndergo into traditional hich they are provided ve tasks to regain the original, echanism is to provide he person who recently a need of physiotherapy exoskeleton hand will ds from the human user. c palm are controlled by ing the Flex sensors and he IEEE 802.15 protocol rovides range up to 10 and implement a cost- ototype model of robotic flex sensor system gives elessly via Bluetooth and f the flex sensor system. subdivisions, the Master ck Diagram for the same 1. Transmitter Section rs connected to the ong with the Bluetooth module. Receiver section connected with receiver ver Bluetooth module [4]

Upload: ijtsrd

Post on 17-Aug-2019

6 views

Category:

Education


0 download

DESCRIPTION

In this paper, we present the mechanism which will be helpful for an individual to cope up with the Rehabilitation exercises. Mechanism proposed here will be useful for assisting human being in case of the Hand Rehabilitation. We propose to design a pair of soft wearable hand glove which comfortably fits on the human hand. One hand will be the Motion detection Glove which includes the Flex Sensors and the other is the assistive hand used for performing the Rehabilitation exercises. Basically our designed glove could be used for robotic orthosis. Raja Vikram Reddy | Aliasgar Barodawala "Hand Rehabilitation Glove" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-2 | Issue-5 , August 2018, URL: https://www.ijtsrd.com/papers/ijtsrd17028.pdf Paper URL: http://www.ijtsrd.com/engineering/electronics-and-communication-engineering/17028/hand-rehabilitation-glove/raja-vikram-reddy

TRANSCRIPT

Page 1: Hand Rehabilitation Glove

@ IJTSRD | Available Online @ www.ijtsrd.com

ISSN No: 2456

International

Research

Hand Rehabilitation GloveRaja Vikram Reddy

1Professor, 2Student, 1,2M HNew Nagpada, Mazgaon,

ABSTRACT In this paper, we present the mechanism which will be helpful for an individual to cope up with the Rehabilitation exercises. Mechanism proposed here will be useful for assisting human being in case of the Hand Rehabilitation. We propose to design a pair of soft wearable hand glove which comfortably fits on the human hand. One hand will be the Motion detection Glove which includes the Flex Sensors and the other is the assistive hand used for performing the Rehabilitation exercises. Basically our designed glove could be used for robotic orthosis. Keywords: Hand Rehabilitation; Flex Sensor; Motion Detection Glove; Exoskeletal GloveOrthosis. I. INTRODUCTION From a purely physiological point of view, the hand is entirely engineered device comprised of 27 bones, 24 muscles, and 32 joints [1]. The term robot is often used but seldom understood. A robot may be broadly defined as a machine that is in some way physically similar to a human or that performs a function similar to that performed by a human [2]. Hand Structures are made up of dense ctissue and the ability of this strong dense connective tissue to glide in relation to one another is essential for the functioning of the normal Hand. Phalangemotor impairment is the most common condition found in the patients suffering from the Accidental

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 5 | Jul-Aug 2018

ISSN No: 2456 - 6470 | www.ijtsrd.com | Volume

International Journal of Trend in Scientific

Research and Development (IJTSRD)

International Open Access Journal

Hand Rehabilitation Glove

Raja Vikram Reddy1, Aliasgar Barodawala2

H Saboo Siddik College of Engineering, Mumbai University,New Nagpada, Mazgaon, Mumbai, Maharashtra, India

In this paper, we present the mechanism which will be helpful for an individual to cope up with the

exercises. Mechanism proposed here will be useful for assisting human being in case of the Hand Rehabilitation. We propose to design a pair of soft wearable hand glove which comfortably fits on the human hand. One hand will be the Motion

ich includes the Flex Sensors and the other is the assistive hand used for performing the Rehabilitation exercises. Basically our designed glove

Hand Rehabilitation; Flex Sensor; Motion Detection Glove; Exoskeletal Glove; Robotic

From a purely physiological point of view, the hand is entirely engineered device comprised of 27 bones, 24

The term robot is often used but seldom understood. A robot may be broadly defined as a machine that is in some way physically similar to a human or that performs a function similar to that performed by a

Hand Structures are made up of dense connective tissue and the ability of this strong dense connective tissue to glide in relation to one another is essential for the functioning of the normal Hand. Phalange al motor impairment is the most common condition

the Accidental

fractures or neurological disarray. The patients who are lacking motor skills undergo into traditional physical therapy training in which they are provided To perform various repetitive tasks to regain the original motor skills as that of The intended use of our mechanism is to provide physiotherapy exercises to the person who recently met hand fracture and is in a need of physiotherapy exercises. In general, the exoskeleton hand will receive motor action commands from the humaThe movements of the robotic palm are controlled by moving the user’s fingers using the Flex sensors and Bluetooth modules which is the IEEE 802.15 protocol in use. Bluetooth module provides range up to 10 meters (LOS).

The project aims to design effective and an affordable prototype model of robotic hand for rehabilitation. The flex sensor system gives control signals to the arm wirelessly via Bluetooth and hand mimics the movement of the flex sensor system. II. BLOCK DIAGRAM The system consists of two subdivisions, the Master & the Slave Section. The Block Diagram for the same is depicted in the Figure 1. Transmitter Section includes the Flex sensors connected to the transmitting ATmega328 along with the Bluetooth HC-05 Bluetooth wireless module. Receiver section includes the Servo motors connected with receiver ATmega328 along with receiver Bluetooth module [4]

Aug 2018 Page: 1392

6470 | www.ijtsrd.com | Volume - 2 | Issue – 5

Scientific

(IJTSRD)

International Open Access Journal

Siddik College of Engineering, Mumbai University,

fractures or neurological disarray. The patients who are lacking motor skills undergo into traditional physical therapy training in which they are provided

perform various repetitive tasks to regain the otor skills as that of original,

The intended use of our mechanism is to provide physiotherapy exercises to the person who recently met hand fracture and is in a need of physiotherapy exercises. In general, the exoskeleton hand will receive motor action commands from the human user. The movements of the robotic palm are controlled by moving the user’s fingers using the Flex sensors and Bluetooth modules which is the IEEE 802.15 protocol in use. Bluetooth module provides range up to 10

The project aims to design and implement a cost-effective and an affordable prototype model of robotic hand for rehabilitation. The flex sensor system gives control signals to the arm wirelessly via Bluetooth and hand mimics the movement of the flex sensor system.

system consists of two subdivisions, the Master & the Slave Section. The Block Diagram for the same is depicted in the Figure 1. Transmitter Section includes the Flex sensors connected to the transmitting ATmega328 along with the Bluetooth

wireless module. Receiver section includes the Servo motors connected with receiver ATmega328 along with receiver Bluetooth module [4]

Page 2: Hand Rehabilitation Glove

International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 5 | Jul-Aug 2018 Page: 1393

Figure 1: Block Diagram of Hand Rehabilitation Glove.

A. MASTER SECTION This section acts as a transmitter section. This section includes flex sensors which will be equipped on a transmitting glove. As from the Figure 1, flex sensors will be mounted on each finger of the hand. When bends or force is applied on the flex sensors it will generate the analog signal of each force being applied. These signal then processed in the ATmega328. These signal is then transmit to the receive side by using Bluetooth hc-05 module B. SLAVE SECTION Slave section includes the Servo motors. The signal which is sent from Master side is received by using Receiver Bluetooth HC-05. As shown in the Figure 1 signal is then fed to the ATmega328. According to the value it will control the servo motors. Each servo motor is connected with the each finger & according to the signal each finger will move and the replica of the movement which will be done at the transmitter side will be cloned at the receiver side. III. DESIGNING THE MOTION DETECTION GLOVE A. Mounting Flex sensors The flex sensors are used to detect the motion of each individual finger. Onto each phalange flex sensor is placed in the state of equal spaces from the end. Flex Sensor generates different values for the different degree of bend. B. Mounting Resistor Network In order to generate the difference signals, a voltage divider needs to be applied. Five Voltage divider Networks were designed accordingly

C. Voltage Divider Network Variations in the Values of resistance are needed, so a variable Resistor i.e. Flex sensor with a combination of fixed resistor of 10K connected in series was used, the variations in the voltage were taken from network and fed to the analog pins of ATmega328P microcontroller. D. Cloth Glove A locally available Cotton glove was utilized on to which the flex sensors were mounted. It is shown in Figure 2.

Figure 2: Practically Implemented Motion Detection

Glove.

Page 3: Hand Rehabilitation Glove

International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 5 | Jul-Aug 2018 Page: 1394

E. Power Supply A. For Transmitter

Figure 2: Transmitter Power Supply

Firstly a battery of 3.7 volts was used, now we required 5 volts for the microcontroller and the HC-05 module, so we used a 3.7 volt to 5 volts DC-DC boost convertor and finally 5 volts were fed to both. Block diagram is shown in Figure 2.

B. For Receiver

Figure 3: Receiver Power Supply There were five servo motors which were to be driven. Each Servo motor consumes 800 mA so a single power supply was not sufficient so we came up with a solution to separate the supply to servo motor such that one power supply provides power to 3 servo motors and the other power supply provides power to remaining to servo motors and the microcontroller unit and HC-05 module. Block diagram is shown in Figure 3. IV. DESIGNING THE EXOSKELETON GLOVE This Part will be Exoskeletal Glove which would be worn in hand of the patient claiming physiotherapy exercises. Various parts were designed such as Fixed Clip, Variable Clip, Spring Tensioning mechanism, servo base, and variable palm consoler. A. Fixed Clip Each Finger has two joints, namely distal interphalangeal and, proximal interphalangeal joints, this fixed clip is designed to act as a permanent clip placed on the topmost part of the finger which will be usefull in simulating the distal interphalangeal joints. It is shown in Figure 4.1

Figure 4: Fixed Clip

It will be useful in simulating the distal interphalangeal joints. Two holes are made so that a string could be attached and the servo motor can move the fingers. B. Variable Clip This clip is designed to simulate the proximal in terphalangeal joints of every finger. Here a two way cylindrical hole was made so that the stretch ability could be achieved else it would have remained at one position. It is shown in Figure 5.

Figure 5: Variable Clip

C. Spring tensioning mechanism This mechanism is used for applying stress on the finger. We are using spring which is a medium for applying stress on the finger. Spring is connected on each of the finger through fixed clip.

Figure 6: Spring tensioning mechanism

As shown we designed a mechanism such that we can control the area on to which stress is to be applied. It is shown in Figure 6. D. Servo Base This base was designed to mount the servo motors in a direction suitable for pulling the fingers. Each servo

Page 4: Hand Rehabilitation Glove

International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 5 | Jul-Aug 2018 Page: 1395

motor shaft was connected to through the fixed clip and variable clip. Servo Base is shown in Figure 7.

Figure 7: Servo Base

E. Whole Structural View In order to arrange the whole setup this structure was designed. Various Indications are shown in Figure 4.5.

Figure 8: Whole Structural View

Various indications are shown in Table-I below

Table 1: Corresponding details of indications in

Figure 8 Indication Label

1 Spring attachment for index finger. 2 Spring attachment for middle finger. 3 Spring attachment for ring finger. 4 Spring attachment for little finger. 5 Movable spring stand.

5-6-7 Variable stand for moving spring tensioning mechanism.

8 Servo base Structure for moving the fingers.

9 Spring attachment for thumb. 10 Assistive gripper for Servo Base.

F. Practically Implemented Exoskeletal Glove This is the practically implemented exoskeletal glove. As seen in the Figure 4.7 below springs were attached to each finger and the spring tensioning mechanism could be displaced by 9cm.

Figure 9: Practically implemented Exoskeletal Glove 5. Results and Discussions There are so many things we can do with our fingers and hands without even thinking about it and if each of these movements is accompanied by pain and discomfort, life becomes very difficult. Some conditions can rectify themselves over time and some need expert attention from a physiotherapist. So below are some of the basic exercises which can be performed using Hand Rehabilitation Glove. A. Fist Stretch & Release Make a gentle fist with your thumb wrapped across the fingers and hold it for 30-60 seconds. Then release and spread your hands wide [4]. It is shown if Figure 10.

Figure 10: Fist transition

Try to do this at least four times with each hand. This is the first step in which our designed mechanism will create stress on finger. B. Claw Transition Another exercise to help with motion range is the claw stretch. Hold out the hand in front of you with the palm facing up. Bend over your fingertips to touch the base of each finger joint –hence the claw – and hold this for 30-60 seconds. Release the hand and then repeat at least four times [4].

Figure 11: Claw transition

Page 5: Hand Rehabilitation Glove

International Journal of Trend in Scientific Research and Development (IJTSRD) ISSN: 2456-6470

@ IJTSRD | Available Online @ www.ijtsrd.com | Volume – 2 | Issue – 5 | Jul-Aug 2018 Page: 1396

C. Thumb flexion/extension Begin with your thumb positioned outward & move the thumb across the palm and back to the starting position [4].

Figure 12: Thumb flexion/extension

Our Prototype is based on robotic orthosis which could be used for, 1. Radial nerve injuries 2. Ulnar nerve Injury (Little Finger, Middle Finger

etc.) 3. Carpel Tunnel Syndrome (Excessive keyboard

typing)

References 1. E. F. Shaw Wilgis, "The Wonder of the Human

Hand" JHU Press, 10-Sep-2014.

2. Daniel Hunt, "Industrial Robotics Handbook" Chapter 2, Industrial Press Inc., 1983 H. H. Crokell, “Specialization and International Competitiveness,” in Managing the Multinational Subsidiary, H. Etemad and L. S, Sulude (eds.), Croom-Helm, London, 1986. (book chapter style)

3. M. Atul. Doshi, Sagar. J. Parekh, Dr. Mita Bhowmick, “Wireless Robotic Hand using Flex Sensors”, International Journal of Scientific & Engineering Research (IJSER), Volume 6, Issue 3, Pg. No. 1471-1474, 2015

4. http://www.thephysiocompany.com/blog/hand-and-finger-exercises [Accessed: April. 12, 2004].

5. https://www.webmd.com/a-to-z-guides/broken-hand#1 [Accessed: Oct. 15, 2017].