handbook for ftth osp v1.0

101
HANDBOOK for FTTH OSP (PT TELKOM INDONESIA) Page 1 HANDBOOK for FTTH-OSP v 1.0 (June 2013) Copyright©Fujikura Ltd./Y.N HANDBOOK HANDBOOK HANDBOOK HANDBOOK For For For For Outside Plant Outside Plant Outside Plant Outside Plant- - -Fiber to the Home Fiber to the Home Fiber to the Home Fiber to the Home (FTTH (FTTH (FTTH (FTTH- - -OSP) OSP) OSP) OSP) For For For For PT TELKOM INDONESIA PT TELKOM INDONESIA PT TELKOM INDONESIA PT TELKOM INDONESIA V 1.0 V 1.0 V 1.0 V 1.0 <REFERENCE <REFERENCE <REFERENCE <REFERENCE or DESIGN, or DESIGN, or DESIGN, or DESIGN, WORK WORK WORK WORK IMPLEMENTATION & TESTING> IMPLEMENTATION & TESTING> IMPLEMENTATION & TESTING> IMPLEMENTATION & TESTING> (June 2013) (June 2013) (June 2013) (June 2013)

Upload: chikal-ii

Post on 16-Jul-2015

1.441 views

Category:

Design


94 download

TRANSCRIPT

Page 1: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 1 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

HANDBOOKHANDBOOKHANDBOOKHANDBOOKForForForFor

Outside PlantOutside PlantOutside PlantOutside Plant----Fiber to the HomeFiber to the HomeFiber to the HomeFiber to the Home

(FTTH(FTTH(FTTH(FTTH----OSP)OSP)OSP)OSP)ForForForFor

PT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIA

V 1.0V 1.0V 1.0V 1.0

<REFERENCE <REFERENCE <REFERENCE <REFERENCE ffffor DESIGN,or DESIGN,or DESIGN,or DESIGN,

WORKWORKWORKWORK IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>IMPLEMENTATION & TESTING>

(June 2013)(June 2013)(June 2013)(June 2013)

Page 2: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 2 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Contents

PART-I DESIGN & INSTALLATION ........................................................................ 4

FTTH-OSP DESIGN PRINCIPLES .......................................................................... 5

MATERIALS FOR FTTH-OSP (STO - ODP) .......................................................................... 7

MATERIALS FOR FTTH-OSP (HRB: Hign-Rise Building) ......................................................... 8

1. FEEDER CABLE DESIGN ++++++++..+++.+++++++... 111.1 Google Map /////////.......................................... 111.2 Skema Kabel Feeder ////..///////////.............../. 121.3 PetaLokasi Duct & Kabel Feeder //////////.///..///////. 151.4 Sample Design of Feeder Cable Network /////.//.//////////............. 151.5 Core Assignment Diagram /////////././///.//////.. 191.6 General Concept for Feeder Cable Design /////./..///////////............ 22

2. DISTRIBUTION CABLE DESIGN ++++++++.+++++++++++ 252.1 Google Map ////////..////////////... 252.2 Skema Kabel Distribusi /////////..//////////// 252.3 Sample Design of Distribution Cable Network /////.////////////............ 282.4 Branching ODP //////..////////////.......... 322.5 Duct Usage for Distribution Network & Drop-core Installation (Underground) .......................... 33

3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN ++++++++............. 343.1 Duct / Buried Section /////.////////////............... 343.2 Aerial Section /..////////////............................ 37

4. CABLE RACK / OTB RACK IN STO BUILDING +++++..+++.+++++++++ 41

Page 3: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 3 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

5. HIGH-RISE BUILDING (HRB) DESIGN ......................................................................... 425.1 Materials for HRB Solution /////////........................................... 425.2 Design Concept for HRB Solution ////..///////////.............../.. 435.3 Type of ODC for High-Rise-Building //////////.///..///////.. 445.4 Example of Cable Tray/Trunking /////.//.//////////............. 455.5 Sample Design: Skema Distribusi /////////././///.//////.. 465.6 Sample Design: Peta Lokasi Distribusi /////./..///////////............ 47

6. REFERENCE ++++++++.+++++++++++ 506.1 Pondasi ODC-C-144 Splitter ////////..////////////... 516.2 Pondasi ODC-C-288 Splitter /////////..///////////... 526.3 Pondasi ODP Pedestal & HH-PIT-60 /////.////////////.............. 536.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300) .../..////////////.......... 546.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300) .............................................................. 556.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800) .............................................................. 566.7 Installation of ODP Wall ............................................................................ 576.8 Form for Core Assignment Diagram ............................................................................ 596.9 Installation Check Sheet ............................................................................ 636.10 List of Assembly Unit Designator ............................................................................ 67

PART-II ACCEPTANCE TESTING ........................................................................ 73

1. TEST PROCEDURE +++++++++++................................ 74

2. OPM MEASUREMENT ......................................................................... 862.1 Application of Measurement Forms /////.////////////............... 872.2 Measurement Forms /..////////////............................ 92

Page 4: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 4 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Page 5: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 5 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

FTTH-OSP DESIGN PRINCIPLES (1)

1. FTTH OSP Design Work (Feeder & Distribusion) shall be carried out in accordance with the frame of this document.

2. LINK BUDGET

1) Descriptions in the Contract:

The Design shall ensure the FTTH OSP System Power Budget of the GPON OLT to ONU (in the configuration of 1:4 Splitter at ODC and 1:8 Splitter at ODP) shall be 28dB (including the margin of 3dB).

2) Applicable Power Budget in the Project:

� Contract Requirement: 28dB - 3dB (Margin) = 25dB (ITU-T G.652D @ Wave Length 1310nm=0.35dB/km)

� Requirement by KBB: 25dB - 2dB = 23dB (including 2dB as an Additional Margin due to an incidental increment of the loss in OSP during an operation)

� Link Budget to be applied for the Project: 25dB @ 1310nm

� We may try however, to keep 23dB @ 1310nm as far as practicable.

Page 6: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 6 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

FTTH-OSP DESIGN PRINCIPLES (2)

3. FTTH OSP Design shall be composed of the following:

3.1 Feeder Cable Design

1) Google Map per STO

2) Skema Kabel Feeder (Schematic Drawing)

3) Skema Duct (Schematic Drawing)

4) Peta Lokasi Duct & Kabel Feeder (Location Map)

5) Special Design (MH Modification, Duct Bridge etc.)

3.2 Distribution Cable Design

1) Google Map per Lokasi

2) Skema Kabel Distibusi

3) Peta Lokasi Distribusi

4) Special Design (HH Modification, Modified ODP Foundation etc.)

Page 7: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 7 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Feeder Cable

DC-OF-SM-

12D/24D/48D/

96D/144D/288D

ODC

ODC-C-48/144/288 SplitterNote: ODC-C-48 = Wallmount Type

Pass through closure Type/Designator

for 48core Star/Ring SC-OF-SM-PT-48

for 96core Star/Ring, 144core Star SC-OF-SM-PT-144S

for 144core Ring SC-OF-SM-PT-144R

for 288core Star SC-OF-SM-PT-288S

for 288core Ring SC-OF-SM-PT-288R

Inline closure Type/Designator

for 12c-24c SC-OF-SM-24

for 12c-48c SC-OF-SM-48

for 12c-96c SC-OF-SM-96

for 12c-144c SC-OF-SM-144

for 12c-288c SC-OF-SM-288

STO

ODC

ODP (Aerial)

ODP-SSW-8(1:8 Splitter built-in)

Branching ODP (Pole/Wall Mount)

ODP-PW-BR

Branching ODP (Pedestal)

ODP-PL-BR

ODP (Wall Mount)

ODP-PW-8/16

Distribution Cable

(Aerial)

AC-OF-SM-8/12/24-SC

ODP (Pedestal)

ODPPL-8/16

Distribution Cable

(Duct)

DC-OF-SM-8/12/24-SC

Passive Splitter

PS-1-2-ODC/

PS-1-4-ODC

PS-1-8-ODP

Line Guard/

Suspension

C-Clamp

Materials for FTTH OSP (STO - ODP)

OTB

TC-OF-SM-

12/24/48/72/96/144

Page 8: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 8 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Cable Trunking and Accessories

Splitter for ODC-HRB

PS-1-4-ODC-HRB

Materials for FTTH-OSP (HRB: High-Rise Building)

ODC-HRB (Cabinet)

ODC-HRB-420

ODC-HRB-240

ODC-HRB-180

ODC-HRB(Rack)

ODC-HRB-RACK-480

ODC-HRB-RACK-240

ODC-HRB-RACK-120

19 inch Rack

TC-OF-R-19

or

Indoor Cable

(1-C Low Friction)

IC-OF-SM-1D

ODC-HRB

ODP-HRB

ODP-HRB-16/32 PS-1-8-ODP-HRB

Indoor Cable

(2-C Low Friction)

IC-OF-SM-2D

ROSETTE

RS-IN-SC-1P/

TC-MK-SC-1P

FUSE-CONNECT

ISC-UPC-FD

T-JointCable Trunking Elbow (Flat Angle)

Page 9: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 9 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

LIST OF MATERIALS AND INSTALLATION MANUALS (1/2) As of: 01-June-2013

No. Spec.No. Manual.No. Sub manuals

1 - 5. ESMDDLT000*****K

6 ESMDDLT00028824K

7 - 8. JBT-05166A

9 - 12. ESMDALT0000****K

13-16 ENZDSCDLT0*****K

17 - 20 ENZDSCALT00****K

21-23 ESMDDLT0000****K

24 JBT-05027B

25 - 26 JBT-05026-> JBT-05391

49 - 50 JBT-04109A

51 - 52 JBT-04770D

53 - 54 JBT-04109A

55 - 56 PNJHC-1101-54-02(2.8mm)

57 - 75 TS1211-01

76 - 78 PNJBC-0516-54-03 PNJBC-0516-82-01 ODC-C sub manual_130214

79 PNJBC-0516-54-04 PNJBC-0516-82-01 ODC-C sub manual_130214

80-81 PNJCS-0013-54-10

82 - 83 PNJCY-0085-54-03 PNJCY-0085-82-01 ODP-CA sub manual_130323

84 - 87 PNJBC-0516-54-06

88 - 89 JEMBO Pedestal + ODP-CA PNJCY-0085-82-01

90 - 95 PNJBC-0516-54-07 PNJBC-0516-82-04 TC-SM sub manual_130225

96 PNJBC-0470-54-04 PNJBC-0470-82-02

97 PNJBC-0472-54-08A

98 PNJBC-0516-54-08

99-101 PNJBC-0516-54-09 PNJBC-0516-82-06

102 - 106 PNJBC-0516-54-10

107 - 111 PNJSC-1077-54-03Rev.1

112 - 116 PNJBC-0516-54-11

117 - 121 PNJSC-1077-54-04Rev.1

200 PNJCY-0084-54-02

201 PNJCY-0084-54-01

202 PNJCY-0084-54-04

203 PNJCY-0084-54-03

204 PNJCY-0084-54-05

Manuals will be available upon supply of the material

Manauals not applicable

DC-OF-SM-*D (SM.D D - LT */*T)

DC-OF-SM-*-SC (SM.D D - LT */*T)

AC-OF-SM-8-SC (OGGDE-SSW)

Name File

AC-OF-SM-*D (SM.D A - LT */*T)

DC-OF-SM-*C (NZDS.C D - LT */*T)

AC-OF-SM-*C (NZDS.C A - LT */*T)

DC-OF-SM-288D (SM.D D - LT 288/24T)

DC-OF-SM-*D (OG8ETSWBE)

AC-OF-SM-*-SC (OGNM4WTGDE-SSW)

GC-OF-SM-1D (FR-OGINE)

HC-OF-SM-*D (FR-OGNMGDE-SSD)

GC-OF-SM-1D (FR-OGINE)

Patch cord (2.8mm, BIS-B)

Pigtails and Patchcords

ODC-C-* Splitter

ODC-C-48 Splitter

ODC-CU (FSCO-HHS)

ODP-CA-* for Pole Mount

ODP-A-*

ODP-PL-* (Pedestal_Box+ ODP-CA-* For_Wall_mount)

TC-SM-*

RS-IN-SC-1P (FPB-103A(S))

RS-IN-SC-2P (FPB-302-2SC(PT))

House Hook

Cable cleat

RS-IN-SC-4P (RS-IN-SC-4)

TC-MK-SC-*

PS-1-*-ODC (Optical Spitter Module 1 x N Type)

PS-1-*-ODP(PLC Type 1xN Splitter)

PS-2-*-ODC (Optical Spitter Module 2 x N Type)

PS-2-*-ODP (PLC Type 2xN Splitter)

Deadending Wire Vice (C clamp)

Drop Cable Clamp (S Clamp)

Selft-Support Wire Line Guard (Line Guard 2.6mm)

Page 10: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 10 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

LIST OF MATERIALS AND INSTALLATION MANUALS 2/2) As of: 01-June-2013

No. Spec.No. Manual.No. Sub manuals205 PNJCY-0084-54-06

206 PNJCY-0084-54-07

207 PNJCY-0084-54-08

400 - 401 PNJHC-1101-53-01

402 PNJCY-0067-54-18 PNJC-0067-82-04

403 PNJHY-0001-53-11

404 PNJHY-0001-53-10

405 PNJHY-0107-53-05

406 PNJHY-0107-54-21Rev.2 JDAA-11-12-0048D

PNJHY-0107-54-21Rev.2 JDAA-11-13-0075

407 PNJBC-0480-54-17

408 PNJBC-0480-54-17

409 PNJBC-0480-54-17

410 B-12F0401 PNJCY-0085-82-03

411 B-12F0401 PNJCY-0085-82-03

412 PNJBC-0085-54-02 PNJCY-0085-82-01

413 PNJBC-0085-54-02 PNJCY-0085-82-01

414 JBT-04260B

415 JBT-04260B

416

417

418

419

420

421 PNJBC-0516-54-12 PNJBC-0516-82-09A

422 PNJBC-0516-54-12 PNJBC-0516-82-09A

423 PNJBC-0516-54-12 PNJBC-0516-82-09A

424 PNJBC-0516-54-13 PNJBC-0516-82-10

425 PNJBC-0516-54-13 PNJBC-0516-82-11

426 PNJBC-0527-54-07

427 PNJBC-1077-54-03Rev.1

Manuals will be available upon supply of the material

PS-1-8-ODP-HRB

ODP-HRB-16

PS-1-4-ODC-HRB

Pass through closureType4 ( For 288core Ring)

ODC-HRB-420

ODC-HRB-240

ODC-HRB-180

ODP-HRB-32

Low Friction Indoor Cable , 2C

Pass through closureType1 ( For 48core Star/Ring )

Pass through closureType2 ( For 96core Star/Ring )

Pass through closureType3 ( For 144core Ring )

Pass through closureType4 ( For 288core Star)

ODP-BR for Branching (3 Hole Type) , Pole mounting type

ODP-BR for Branching (3 Hole Type) , termasuk Dome Pedestal

ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 8 Port

ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 16 Port

Low Friction Indoor Cable , 1C

Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 4 Port

L-clamp

Flex Band IBT-206

BW-Clamp

Free Bending Optical cord (3mm, BIS-B)

Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 1 Port

Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 2 Port

ODP-SSW (FSCO-AS-SP(in/splice))

FIELD INSTALLBLE SC CONNECTOR (FAST-SC-SM-09/CO)

FIELD INSTALLBLE SC CONNECTOR (FAST (N) -SC-SM-UNI/GT)

FUSION CONNECTOR (Fuseconnect-SC-SF-SM-20/30)

FUSION CONNECTOR (Fuseconnect-SC-DC) for Drop cable

FUSION CONNECTOR (Fuseconnect-SC-LF) for LowFriction cable

Name File

Manauals not applicable

Page 11: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 11 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1. FEEDER CABLE DESIGN

A. The Feeder Cable Route shall be planned to utilize the existing duct route as the first priority so as to minimize the road excavation length.

B. The capacity of Feeder Cables designed/implemented by the previous TOS/PO as well as for the followings shall be taken into account at the Feeder Cable Capacity Planning:

1) AL PRO: Existing Facility such as MSAN, RK, etc.

2) Node B Project

3) GDI: Government Digitalization Network

1.1 GOOGLE MAP1) Nama STO: legend berbentuk Rumah (Warna Merah)

2) Route Feeder: warna Merah

3) Nama ODC sesuai dengan Lokasi/Cluster

4) Kapasitas ODC/ Jumlah Homepass

5) Boundary ODC/Lokasi/Cluster dg Boundary Area Potensi

Page 12: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 12 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.2 SKEMA KABEL FEEDER

► Purpose: Information required for the Feeder Cable Work

A. OTB at STO

OTB to be installed with the symbol Telkom Standard and indicated with the designator in BoQ:

Example: TC-OF-SM-xx (yy)

B. Feeder Cable

Indication: Black Line (New: 0.6 point, Existing: 0.3 point)

Information:

1) Type (Duct/Aerial) and capacity of cable

2) Length of cable

3) Core Assignment

Note: The younger core number shall be assigned for the far end (the last position) and

spare cores (Cadangan).

Total Quantity of OTB

Type of OTB

Page 13: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 13 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

IDENTIFICATION OF FEEDER CABLE

FE XXX 01-01-01 (01-288)

Core No. In Cable

Segment No.

Feeder No.

Code STOCode Feeder Cable

DC-OF-SM-XXX-xxxxM

Cable Length

in meter

No. Of Cores

Type of Cable

Duct Cable: DC-OF-SM

Aerial Cable: AC-OF-SM

Branch-Segment No.

Note:

Cable Line:

� New: Tebal (e.g. 6pt.)

�Existing: Tipis (e.g. 3pt.)

Identification:

� New: Bold Font

�Existiong: Normal Font

Page 14: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 14 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

C. ODC

D. MH/HH/CLOSURE

1) MH/HH: Name of Existing MH/HH or Type of New MH/HH

2) Closure:

a. Straight Joint: SC-OF-SM-xxx

b. Pass-through Joint: SC-OF-SM-xxx-PT

ODC Capacity

ODC No. “FA”, “FB”, .......

Code STO

Code ODC

xx PS 1:4 (xxx HP)

Number of Homepass

Code Splitter 1:4

Number of Splitter 1:4

Coordinates Lokasi ODC

ODC-XXX-FA-288

( - )Assigned core to be

terminated

Page 15: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 15 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.4 SAMPLE DESIGN OF FEEDER CABLE NETWORK

1.3 PETA LOKASI DUCT & KABEL FEEDER►►►► Purpose: Information required for the Civil Work shall be plot on the scaled map

1) SKEMA DUCT

(Refer to 1.4.1)

2) SKEMA KABEL FEEDER

(Refer to 1.4.2)

3) PETA LOKASI

KABEL FEEDER

(Refer to 1.4.3)

Lokasi CC

ODC-ABC-F+-288

STO

ABC

24

15.0

AB

C

01/0

1A

BC

01/0

2A

BC

01/0

3A

BC

01/x

xA

BC

01/y

y

6 6

66

4

AB

C

02/0

2

ABC

02/01

AB

C

02/x

x

100.0 100.0

100.0

100.0

100.0

HH-2

HH-

80

DD-BM-HDPE-1

35.0

HH-1

HH-1

DD-BM-HDPE-1

150.0

DD

-BM

-HD

PE

-BIG

-1D

D-B

M-

HD

PE

-

BIG

-1

150.0

bb

b.

0

Lokasi AA

ODC-ABC-F+-144

Lokasi BB

ODC-ABC-F+-288

Lokasi DD

ODC-ABC-F+-144

JL

.A

BC

RA

YA

JL.

AB

CII

JL.ABC I

aaa.0

DD

-BM

-

HD

PE

-

BIG

-1

HH-1Cab

le s

lack (

10)

sh

all b

e p

rovid

ed

at

every

1000m

of

cab

le len

gth

. (I

n c

ase

of

DD

-BM

-HD

PE

, H

H-1

/2 s

hall b

e

insta

lled

.)

Legend:

: Assigned Duct for New Cable

: Vacant Duct

: Occupied Duct

Lokasi CC

ODC-ABC-F+-288

xx PS 1:4 (yyHP)

(241-288)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

Lokasi DD

ODC-ABC-F+-144

xx PS 1:4 (yyHP)

(217-240)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

Lokasi AA

ODC-ABC-F+-144

xx PS 1:4 (yyHP)

(121-144)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

Lokasi BB

ODC-ABC-F+-288

xx PS 1:4 (yyHP)

(73-120)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

STO ABCTC-SM-144 (3)

FE-ABC-01-01 (01-144)

DC-OF-SM-144D ++m

FE-ABC-01-01-01 (121-144)

DC-OF-SM-24D ++m

FE

-AB

C-0

1-0

2 (

01-1

20)

DC

-OF

-SM

-144D

++

m

FE-ABC-01-02-01 (73-120)

DC-OF-SM-48D ++mCAD

(01 – 72)

FE

-AB

C-0

2-0

1 (

01-2

88)

DC

-OF

-SM

-288D

++

mD

C-O

F-S

M-2

88D

++

m

FE

-AB

C-0

2-

02

(01-2

40)

CAD

(01 – 216)

FE-ABC-02-01-01 (241-288)

DC-OF-SM-48D ++m

FE-ABC-02-02-01 (217-240)

DC-OF-SM-48D ++m

JL.

AB

CR

AY

JL.ABC I

JL.

AB

CII

AB

C

01/0

2A

BC

01/y

y

DC

-OF

-SM

-288D

++

m

FE

-AB

C-0

2-

02

(01-2

40)

Cable Slack (10m) shall be

placed every 1000m of

cable span and/or the

location where the future

demand is expected.

STO

ABC

100.0

ABC

01/01

DD-BM-HDPE-1

150.0

DD-BM-HDPE-1

35.0

HH-

80

HH-2

HH-1

HH-1

DD

-BM

-HD

PE

-BIG

-1

150.0

JL.

AB

CR

AY

JL.

AB

CII

JL.ABC I

Lokasi BB

ODC-ABC-F+-288

Lokasi AA

ODC-ABC-F+-144

Lokasi CC

ODC-ABC-F+-288

Lokasi DD

ODC-ABC-F+-144

DD-BM-1

10.0

DD-BM-1

10.0

DD-ROD-1

15.0

DD

-RO

D-1

xxxx.0

ABC

01/02

ABC

01/03

ABC

01/xx

DD

-BM

-HD

PE

-

BIG

-1

bb

b.

0

aaa.

0

DD

-BM

-HD

PE

-

BIG

-1

HH-1

ABC

02/03

ABC

02/01

ABC

02/xx

ABC

01/xx

ABC

01/xx

ABC

01/yy

ABC

02/02

DD-ROD-

1100000000.0

DD-ROD-

1100000000.0

DD-ROD-

1100000000.0

DD-ROD-

1xxx.0

DD-ROD-

1100000000.0

DD-ROD-

1100000000.0

DD-ROD-

1xxx.0

DD-ROD-

1100000000.0

DD-ROD-

1100000000.0

DD-ROD-

1xxx.0

Page 16: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 16 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.4.1 SKEMA DUCT

STO ABC

24

15.0

ABC

01/01ABC

01/02

ABC

01/03

ABC

01/xxABC

01/yy6

6

664

ABC

02/02

AB

C

02/0

1

ABC

02/xx

100.0

100.0

100.0100.0100.0

HH-2HH-80

DD-BM-HDPE-1

35.0

HH-1HH-1

DD-BM-HDPE-1

150.0

DD-BM-HDPE-

BIG-1

DD-BM-HDPE-

BIG-1

150.0bbb.0

Lokasi AA

ODC-ABC-F+-144

Lokasi BB

ODC-ABC-F+-288

Lokasi CC

ODC-ABC-F+-288Lokasi DD

ODC-ABC-F+-144

JL.ABC RAYA

JL.ABC II

JL.

AB

CI

aaa.0

DD-BM-HDPE-

BIG-1

HH-1

Cable slack (10) shall be provided at every 1000m

of cable length. (In case of DD-BM-HDPE, HH-1/2

according to Page 23, 1.6.3 shall be installed.)

Legend:

: Assigned Duct for New Cable

: Vacant Duct

: Occupied Duct

Page 17: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 17 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.4.2 SKEMA KABEL FEEDER

Lokasi CC

ODC-ABC-F+-288xx PS 1:4 (yyHP)

(241-288)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

Lokasi DD

ODC-ABC-F+-144xx PS 1:4 (yyHP)

(217-240)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

Lokasi AA

ODC-ABC-F+-144xx PS 1:4 (yyHP)

(121-144)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

Lokasi BB

ODC-ABC-F+-288xx PS 1:4 (yyHP)

(73-120)NNNN xxxxxxxxxxxx°°°°xxx.xxxx

E yyy °°°° yyy.yyyy

STO ABC

TC-SM-144 (3)

FE-ABC-01-01 (01-144)

DC-OF-SM-144D ++m

FE-ABC-01-01-01 (121-144)

DC-OF-SM-24D ++m

FE-ABC-01-02 (01-120)

DC-OF-SM-144D ++m

FE-ABC-01-02-01 (73-120)

DC-OF-SM-48D ++m

CAD

(01 – 72)

FE-ABC-02-01 (01-288)

DC-OF-SM-288D ++mDC-OF-SM-288D

++m

FE-ABC-02-02

(01-240)CAD

(01 – 216)

FE-ABC-02-01-01 (241-288)

DC-OF-SM-48D ++m

FE-ABC-02-02-01 (217-240)

DC-OF-SM-48D ++m

JL.ABC RAYA JL.

AB

CI

JL.ABC II

ABC

01/02ABC

01/yy

DC-OF-SM-288D

++m

FE-ABC-02-02

(01-240)

Cable Slack (10m) shall be

placed every 1000m of cable

span and/or the location where

the future demand is expected.

(Note: Do not show on drawing)

( )

Page 18: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 18 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.4.3 PETA LOKASI KABEL FEEDER

STO

ABC

ABC

01/01

DD-BM-HDPE-1

150.0DD-BM-HDPE-1

35.0

HH-80

HH-2

HH-1 HH-1

DD-BM-HDPE-

BIG-1

150.0

JL.ABC RAYA

JL.ABC II

JL.

AB

CI

Lokasi BB

ODC-ABC-F+-288Lokasi AA

ODC-ABC-F+-144

Lokasi CC

ODC-ABC-F+-288

Lokasi DD

ODC-ABC-F+-144

DD-BM-1

10.0

DD-BM-1

10.0

DD-ROD-1

15.0m

ABC

01/02ABC

01/03

ABC

01/xx

DD-BM-HDPE-

BIG-1

bbb.0aaa.0

DD-BM-HDPE-

BIG-1

HH-1

ABC

02/02

ABC

02/01

ABC

02/xx

ABC

01/xxABC

01/xx

ABC

01/yy

ABC

02/03

DD-ROD-1

xxx.0mDD-ROD-1

100.0m

DD-ROD-1

100.0m

DD-ROD-1

100.0m

DD-ROD-1

100.0m

DD-ROD-1

100.0m

DD-ROD-1

100.0m

DD-ROD-1

100.0mDD-ROD-1

xxx.0m

DD-ROD-1

xxx.0m

1. FE-ABC-01

2. FE=ABC-02

Note:

In case if plural cables

will be installed in one

(1) route, Cable No. to

be installed shall be

indicated.

Page 19: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 19 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.5 CORE ASSIGNMENT DIAGRAM

1. CORE ASSIGNMENT DIAGRAM shall be prepared prior to draw the SKEMA KABEL as a tool so as to

arrange the core assignment of the feeder cable easily. (Not for submission purpose)

2. CORE ASSIGNMENT DIAGRAM shall be prepared per each FEEDER CABLE.

3. The higher number of core (e.g. 288 in 288-core cable) shall be assigned from the nearest ODC, and the

youngest number shall be assigned for the furthest ODC or CAD (Spare core).

START

FEEDER CABLE ROUTE PLAN:

=> Draft for Skema Feeder

1. SKEMA DUCT EXISTING shall be referred as the

basic information for the Feeder Cable Route Plan.

2. Plot all ODCs TO BE FED BY THE CABLE

together with its capacity along the existing duct

route.

3. Where the existing duct is not available, new duct

construction or DD-BM-HDPE shall be planned.

4. Plot all prospected/ potential locations including

Al-Pro, MSAN, GDI etc. along the expected

feeder cable route.

Decision of Network

Configuration:

1.Ring

2.Star/Bus

SUM UP the required

number of fiber cores:

1.ODC-144: 24 cores

2.ODC-288: 48 cores

Decision of Feeder Cable Capacity:

1.Required number of cores ≤ 96 → 96C

2.Required number of cores 97 ≥, ≤ 144 → 144

3.Required number of cores 145 ≥, ≤ 288 → 288

4.Required number of cores ≥ 288 → 288 +

another cable according to the required capacity

Preparation of

CORE ASSIGNMENT

DIAGRAM

END

FLOW OF CORE ASSIGNMENT DIAGRAM PREPARATION

Page 20: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 20 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.5.1 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (1): STAR/BUS TOPOLOGY

SKEMA KABEL FEEDER

(Reference for Main Information)

Lokasi AA

ODC-288

(241 – 288)

Lokasi CC

ODC-144

(169 – 192)

Lokasi DD

ODC-144

(145 – 168)

Lokasi BB

ODC-288

(193 – 240)

CAD (72)

(01 – 72)

Lokasi EE

ODC-288

(97 – 144)CAD (24)

(73 – 96)

(01 – 288)

(288) (288) (288)

(01 – 240) (01 – 192)

(145 – 192)

(01 – 72)

(96)

(48) (145 – 168)

(24)

(48)

(97 – 144)(48)

(193 – 240)

(48)(241 – 288)

(24)

(169 – 192)

STO ABC

TC-OF-SM-144 (2)

01 - 24

25 - 48

49 - 72

73 - 96

97 - 120

121 - 144

145 - 168

169 - 192

193 - 216

217 - 240

241 - 264

265 - 288

Lokasi AA

ODC-288

(241 – 288)

Lokasi BB

ODC-288

(193 – 240)STO ABC

Lokasi CC

ODC-144

(169 – 192)

Lokasi DD

ODC-144

(145 – 168)

CAD

(73 – 96)

CAD (72)

(01 – 72)

Lokasi EE

ODC-288

(97 – 144)(288)

(96)

(48)

(48)

(24) (24)

(48) LEGEND:

: Joint Closure

: Fusion Splicing

: Cable (Core)(XX)

Page 21: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 21 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.5.2 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (2): RING TOPOLOGY

Lokasi DD

ODC-288

(145 – 192)

01 2425 4849 7273 9697 120121 144145 168169 192193 216217 240241 264265 288

265 288241 264217 240193 216169 192145 168121 14497 12073 9649 7225 4801 24

Lokasi AA

ODC-144

(265 – 288)STO ABC

Lokasi CC

ODC-288

(193 – 240)

Lokasi EE

ODC-144

(121 – 144)

Lokasi GG

ODC-288

(49 – 96)

Lokasi BB

ODC-144

(241 – 264)

Lokasi DD

ODC-288

(145 – 192)Lokasi FF

ODC-144

(97 – 120)

CAD

(01 – 48)

CAD

(01 – 48)

SKEMA KABEL FEEDER

(Reference for Main Information)

STO ABC

TC-OF-SM-144 (4)

Lokasi AA

ODC-288

(241 – 288) (01 – 288)

(01 – 288)(01 – 288)

Lokasi BB

ODC-144

(241 – 264)

Lokasi CC

ODC-288

(193 – 240)

Lokasi EE

ODC-144

(121 – 144)

Lokasi FF

ODC-144

(97 – 120)

Lokasi GG

ODC-288

(49 – 96)

(48)

(48)

(48)

(48)

(96)

(96)

(96)

Page 22: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 22 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.6 GENERAL CONCEPT FOR FEEDER CABLE DESIGN

1.6.1 ODC SPEC. (Non-HRB Type)

ODC

typeDesignator

Splitter

(1:4)Maximum HP

Feeder

(input Fiber core)

Number of Cable Entry

(Input+Output)

48

(pole)ODC-C-48 Splitter Max. 6pcs 6x32=192

Star ; 12C

Ring ; 24C4

96

(pedestal)ODC-C-96 Splitter Max. 8pcs 8*32=256

Star ; 12C

Ring ; 24C8

144

(pedestal)ODC-C-144 Splitter Max. 18pcs 18x32=576

Star ; 24C

Ring ; 48C12

288

(pedestal)ODC-C-288 Splitter Max. 36pcs 36x32=1152

Star ; 48C

Ring ; 96C12

576

(pedestal)ODC-C-576 Splitter Max. 72pcs 72x32=2304

Star ; 96C

Ring ; 192C24

1.6.2 FEEDER CABLE SPEC.

Fiber Count Number of Tubes Number of Fiber/Tube Tube Diameter Outer DiameterBending Radius

(20 x OD)

12C 2 6 2.1mm 12.8mm 25.6cm

24C 4 6 2.1mm 12.8mm 25.6cm

48C 4 12 2.5mm 13.9mm 27.8cm

96C 8 12 2.5mm 15.6mm 31.2cm

144C 12 12 2.5mm 19.1mm 38.2cm

288C 24 12 2.5mm 22.1mm 44.2cm

Page 23: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 23 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.6.3 HDPE PIPE/HANDHOLE for FEEDER CABLE

In case when the existing duct is not available and new duct (HDPE) will be installed, the following shall be taken into consideration:

1) Feeder Cable with the capacity 288-core:

► HDPE BIG/SUBDUCT BIG shall be used.

► Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.

2) Feeder Cable with the capacity 144-core

► HDPE 33/40/SUBDUCT shall be used.

► Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.

3) Feeder Cable with the capacity 96-core or less

► HDPE 33/40/SUBDUCT shall be used.

► Hand-hole Type HH-2 (L=1200 x W=600 x D=1300) shall be used for all locations

1.6.4 HANDHOLE for ODC

At ODC location, HANDHOLE shall be installed:

1) Type HH-1 (L=1700 x W=1250 x D=1300):

► Where the Jointing Closure from the Feeder Cable with 288/144-core.is installed including the location

where slack is located for future jointing.

2) Type HH-2 (L=1200 x W=600 x D=1300):

► Where Handhole shall be located on the carriage way.

3) Type HH-80 (L=800 x W=800 x D=800):

► Where Handhole will be located on the Green Area (Taman) in the housing area (Perumahan) and where

no jointing closure will be located.

Page 24: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 24 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.6.5 PASS THROUGH CLOSURE for FEEDER CABLE

Through Cable

Type

Model No. (3M)

48core 2179CS Type 1 : 24core tray (1)

Size ; 447mm x 175mm x 107mm

96core, 144core 2179C Type 2 : 24core tray (1)

Type 3 : 24core tray (2)

Size ; 557mm x 215mm x 119mm

288core 2178LS Type 4 : 24core tray (2)

Type 5 : 24core tray (4)

Size ; 557mm x 216mm x 203mm

Option: 24core tray , Re-entry kit

Consultation shall be necessary in case when the other optional items are required.

Page 25: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 25 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2. DISTRIBUTION CABLE DESIGNMaximum Usage of Distribution Cable shall be 80% of the cable capacity:

Maximum No. of ODP: No. of Spare Core (CADANGAN)

1) 8-Core Cable: 6 (Only for Branch Section) 2 CORE CAD.

2) 12-Core Cable: 10 2 CORE CAD.

3) 24-Core Cable: 20 4 CORE CAD.

2.1 GOOGLE MAP1) ODC (Name/Capacity)

2) Distribution Cable Route

3) Location of ODP

2.2 SKEMA KABEL DISTRIBUSI

► Purpose: Information required for the Distribution Cable Work1) ODC

ODC Capacity

ODC No. “FA”, “FB”, .......

Code STO

Code ODC

ODC-XXX-FA-288

Page 26: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 26 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2) DISTRIBUTION CABLE

DSXXX-FE 01-01-01/01-01-01 (01-24)

Core No. In Cable

Segment No.

Label Feeder (Feeder No., Segment No.)Code STO

DC-OF-SM-24SC-xxM

Cable Length in meter

Designation for “Easy to Split” Cable

No. Of Cores

Type of Cable

Duct Cable: DC-OF-SM

Aerial Cable: AC-OF-SM

Code Distribution CableDistribution No.

Branch-Segment No.

Page 27: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 27 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

3) ODP

FA/D01/xx/yy

(xx)

No. No.

Number of Splitter 1:8

“1”: ODC-8

“2”: ODC-16

ODP No.

Note: 1. Continuous number starting from D01:

example: 10 ODP on D01, ODP on D02 shall be

started from No.11.

2. ODP No. shall be given from the far most ODP

from ODC location.Distribution Cable No.

ODC No.

Core No. to be terminated at ODP

e.g. from 01 to 24

The largest No. of care shall be allocated to the nearest

ODP from ODC.

House No. in front of

ODP Location

Coordinates Lokasi ODP

Note: Grounding shall be placed at the last ODP for each distribution cable.

Page 28: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 28 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.3 SAMPLE DESIGN OF DISTRIBUTION CABLE NETWORK

1) SKEMA KABEL DISTRIBUSI

2) PETA LOKASI KABEL DISTRIBUSI

2.3.1 CASE-1: UNDERGROUND/DUCT CABLE

ODC-F+-144

xx PS 1:4 (yyHP)

DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-10) DSABC-FE-01-01/01-03 (01-09) DSABC-FE-01-01/01-xx (01-05)

F+/D01/07/02

(11-12)N ++++...

E +++.......

N ++++...

E +++.......

F+/D01/06/01

(10)

N ++++...

E +++.......

F+/D01/05/01

(09)

ODP-PW-BRN ++++...

E +++.......

F+/D01/01/02

(03-04)

N ++++...

E +++.......

CAD

(01-02)

DC-OF-SM-12-SC +..m DC-OF-SM-12-SC +..m DC-OF-SM-12-SC +..m DC-OF-SM-12-SC +..m

3 4 9 10 16 17 31

F+/D01/04/01

(08)

DSABC-FE-01-01/01-03-01 (08)

DC-OF-SM-8-SC +..m

N ++++...

E +++.......

JL. +++++++..

HH-2

ODC-F+-144

xx PS 1:4

(yyHP)

DD-BM-HDPE-1 +..mDD-BM-HDPE-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-1 +..m

DD-BM-1 +..m

DD-BM-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-1 +..m

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30

31

32

DD-BM-HDPE-1 +..m

F+/D01/07/02 F+/D01/06/01F+/D01/05/01

ODP-PW-BR F+/D01/01/02

F+/D01/04/01

JL. +++++++..

Note:

At the BRANCHING, the core

assignment and the ODP No. shall be

in accordance with the rule below.

Page 29: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 29 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

STO ABC NAMA LOKASI Cluster AA (ODC-F+-144)DISTRIBUTION

CABLE No.D-01 CAPACITY 12-CORE

FEEDER SEGMENT DISTRIBUTION SEGMENT

OTB

Port No.

ODC

PORT No.

SPLITTER 1:4 ODC TRAY CORE

No.No. Port No. PORT No.

49 1 1

1

1

1 1

2 2 2

3 3 3

4 4 4

50 2 2

1 5 5

2 6 6

3 7 7

4 8 8

51 3 3

1 9 9

2 10 10

3 11 11

4 12 12

7 6 5 4 3 2

3) CORE ASSIGNMENT DIAGRAM (For CASE-1)

1

CAD

8-C

Page 30: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 30 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.3.2 CASE-2: AERIAL CABLE

1) SKEMA KABEL DISTRIBUSI

2) PETA LOKASI KABEL DISTRIBUSI

ODC-F+-144

xx PS 1:4 (yyHP)

DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-11) DSABC-FE-01-01/01-03 (01-10) DSABC-FE-01-01/01-xx (01-05)

F+/D01/08/01

(12)N ++++...

E +++.......

N ++++...

E +++.......

F+/D01/07/01

(11)

N ++++...

E +++.......

F+/D01/06/01

(10)

ODP-PW-BRN ++++...

E +++.......

F+/D01/01/01

(05)N ++++...

E +++.......

CAD

(01-04)

AC-OF-SM-12-SC +..m AC-OF-SM-12-SC +..m AC-OF-SM-12-SC +..m AC-OF-SM-12-SC +..m

3 4 9 10 16 17 31

F+/D01/05/01

(09)

DSABC-FE-01-01/01-03-01 (09)

AC-OF-SM-8-SC +..m

N ++++...

E +++.......

JL. +++++++..

HH-2

ODC-F+-144

xx PS 1:4

(yyHP)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30

31

32

F+/D01/08/02 F+/D01/07/01F+/D01/06/01

ODP-PW-BR F+/D01/01/01

F+/D01/05/01

JL. +++++++..

BC-PP 3m 30m 45m 45m 45m

45m

25m+.m

LEGEND

: New Pole

: Existing PoleBranching ODP

(1 x 1:8 Splitter)

ODP Aerial

(1 x 1:8 Splitter)

30m

Note:

At the BRANCHING, the core

assignment and the ODP No. shall be

in accordance with the rule below.

Page 31: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 31 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

3) CORE ASSIGNMENT DIAGRAM (For CASE-2)

STO ABCABCABCABC NAMA LOKASI Cluster AA (ODC-F+-144)DISTRIBUTION

CABLE No.D-01 CAPACITY 12-CORE

FEEDER SEGMENT DISTRIBUTION SEGMENT

OTBPort No.

ODC PORT No.

SPLITTER 1:4 ODC TRAYCORE No.

No. Port No. PORT No.

49494949 1111 1111

1

1111

1 1

2 2 2

3 3 3

4 4 4

50505050 2222 2222

1 5 5

2 6 6

3 7 7

4 8 8

51515151 3333 3333

1 9 9

2 10 10

3 11 11

4 12 12

ODP No. 15 34 2678

CAD

12-C 12-C

8-C

Page 32: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 32 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Main Cable

(SCPT-8/12/24-core)

ODP Pedestal/Wall

Capacity: 8 or 16

ODP Pedestal/Wall

Capacity: 8 or 16

Branching Cable

(SCPT-8-core)

Branching ODP

(1 x 1:8 Splitter)

Designator:

ODP-PL-BR

2.4 BRANCHING ODP

1) Underground Cable

(Pedestal/Wall Mount)

Branching ODP shall be used in case when the several ODP locations are not suitable to be fed by the main cable but

independent cable installation is also not efficient due to the limited number of ODP (Less than 8 ODP).

Branching ODP:

1)Branching ODP is applicable for both underground as well as aerial distribution cable design.

2)Type of ODP is “Cabinet” type to be mounted on: WALL, POLE and PEDESTAL.

3)The cable to be branched from the main cable shall be of “8-Core”.

4)The number of ODP on branched cable shall be less than 8.

5)The branching ODP is able to accommodate only one (1) unit of 1:8 Splitter.

2) Aerial Cable

(Pole Mount)

Main Cable

(SSW-8/12/24-core)

ODP Aerial

Capacity: 8

ODP Aerial

Capacity: 8Branching Cable

(SCPT-8-core)

Branching ODP

(1 x 1:8 Splitter)

Designator:

ODP-P/W-BR

Page 33: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 33 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.5 DUCT USAGE FOR DISTRIBUTION NETWORK &

DROP-CORE INSTALLATION (UNDERGROUND)

ODC – ODP/ ODP – ODP

1)DD-BM-HDPE

2)BC-TR-1.5 + DD-HDPE

ODP (HH-PIT-60) – HH-PIT-40/

HH-PIT-40 – HH-PIT-40

1) BC-TR-0.6 + DC-SD-1 BigHH-PIT-60

HH-PIT-40

HH-PIT-40

HH-PIT-40 - Premises

1) BC-TR-0.4 + PP-OF-OUT(PVC ¾”)

Page 34: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 34 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN

1) Bila ditemukan jalan buntu pada perumahan dengan jalak Drop core <100 meter maka

penempatan ODP diletakkan di ujung jalan masuk Blok Perumahan, Gambar Terlampir: 1) When you find a blind alley which need drop core cable less than 100 m, the ODP should be placed at

the entrance of the alley. Please see the illustration below.

General Preparation for the Distribution Cable Design:

Prior to plotting ODP on the map, ODP Boundary (Max. 8 or 16HP) shall be designated so

that the number of ODP and its location can be planned efficiently.

3.1 DUCT/BURIED SECTION

Page 35: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 35 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2) Bila ditemukan jalan buntu pada perumahan dengan jalak Droop core >100 meter maka

diperbolehkan menggunakan ODP Branch dari kabel distribusi untuk kabel yang akan menuju ke

ODP dengan jumlah branch sesuai denga HP, Gambar Terlampir :2) When you find a blind alley which need drop cable more than 100 m, it is allowed to use the ODP Branch from the

main distribution cable according to the quantity of HP. Please see the illustration below.

Page 36: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 36 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

3) Bila ditemukan jalan tidak buntu pada perumahan maka penarikan kabel distribusi dapat dilakukan

secara mengelilingi perumahan yang letak ODP di sesuaikan dengan jumlah HP, Gambar Terlampir :3) When it is not a blind alley, span of the cable should pass around the complex and placement of ODP should be

adjusted according to the HP. Please see the illustration below.

Page 37: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 37 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

3.2 AERIAL SECTION1) Sample Design based on Duct Cable Design Standard

=> (Some consideration due to particularity of the aerial cable shall be required.)

6.5m 45m

6.5m

30m

45m45m

40m

45m45m

45m11m

45m

45m

25m

25m

6.5m

35m45m

45m45m

Road width

more than 6m

Road width

less than 6mAC-OF-SM-12-SC

AC-OF-SM-8-SC

AC-OF-SM-8-SC

AC-OF-SM-12-SC

ODP-BR

ODP-BR

Note: Location where special

consideration is required due

to a particularity of the aerial

cable installation

: ODC

: ODP

1) ODP-SSW-8

2) ODP-BR

: HH-2/HH-80

: New Pole 7m/9m

LEGEND

C-CLAMP x 2

Detail for Riser Part

SSW CABLE

Cable part shall be

protected with Spiral

for outdoor use (Black

color)

Detail for

Riser Part

Note: Prior to plotting ODP on the map, ODP Boundary (Max. 8HP) shall be designated so that the number

of ODP and its location can be planned efficiently.

Page 38: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 38 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2) Sample Design based on Particularity for Aerial Cable

: Additional Pole for

Drop Core

LEGEND for Additional Item

: Drop Core Run

6.5m

45m

6.5m

40m

45m

45m

40m

45m

45m

45m11m

45m

45m

25m

25m

6.5m

35m

45m

45m

45m

Road width

more than 6m

Road width

less than 6m

30m

35m

10m

15m

25m

30m

30m

40m

35m

25m

35m

Detail "Drop-A"

Detail "Drop-B" Detail "Drop-C"

Note: Location where special

consideration is taken due to

a particularity of the aerial

cable installation

Some particular consideration required for

Aerial Cable Design

1. Additional pole(s) may be required for the

drop cable installation. (Actual installation

of additional poles shall be decided in

accordance with contract with the

developper/owner)

2. Road width less than 6m can be crossed by

the drop cable as far as the road traffic will

not be disturbed otherwise new pole shall

be installed.

3. Location of ODP shall be decided so that:

1) Drop cable can be installed along SSW

cable.

2) Drop cable can be installed indipendently

for one (1) span (2 spans at maximum)

Page 39: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 39 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

C-CLAMP x 2

SSW CABLE

Cable part shall

be protected with

Spiral for outdoor

use (Black color)

3) Details of SSW Installation

A. Details of Riser Part B. ODP-SSW Location

10cm

ODP-SSW-8

B-1. With C-CLAMP

C. Cable Allignment

As far as it is practical, the

cable shall be installed so

that the suspension wire is

always above the cable part.

Suspension Wire

Cable Part

At the cable laying, turns in

the cable shall be released

by turning the cable winding

while making the 8-figure.

50mm

Bend

150mm remove sheath

D. C-LAMP E. Line Guard Installation

±30cm

Line Guard

L= 51cm

ODP-SSW-8

B-2. With LINE GUARD

SUSPENSION CLAMP

±25cm

< 120°°°°

LINE GUARD shall be installed where:

1. One (1) in every three (3) poles in the

straight line.

2. At the pole beside the ODP-SSW is

installed except the location where C-

CLAMP is installed.

Caution:LINE GUARD shall be fixed and the Suspension

Wire at C-CLAMP shall be bent ONLY after all

ODP-SSW installation have been completed

and the cable allignment has been confirmed

so that no turn is contained in the cable span.

: SSW Cable (Japan)

LEGEND

: C-Clamp (Japan)

Page 40: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 40 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Drop Cable

(Aerial)

HC-OF-SM-2D

4) Details of Drop-Core Solution

Detail "Drop-A"

Messenger wire from drop cable to pole or

φ1.2mm galvanized steel wire with sheath coating

Detail "Drop-B"

Detail "Drop-C"

: S-Clamp (Japan)

LEGEND

: D-Clamp (Japan)

: BW-Clamp (Local)

FUSE-CONNECT

ISC-UPC-FD

ROSETTE

RS-IN-SC-1P/

TC-MK-SC-1P

Details of "Home Connect"

ODP-SSW-8

ODP-PL/PW-

8/16Drop Cable

(Underground)

GC-OF-SM-2D

Wire Grip 3/8"

with double nut

Page 41: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 41 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

4. CABLE RACK/OTB RACK IN STO BUILDING

Note:

1. The cable routing in the STO building shall be

measured so as to estimate the cable length

from the duct entrance at the Cable Chamber

until the OTB.

2. In case when the new rack shall be provided, the

rack to be installed shall be of same type and

the same color with the existing one.

3. In the decision of the location of 19” rack

installation, well coordination with DBB, Telkom

Area and/or WASPANG is required.

4. When the location of new 19” Rack installation

is fixed, the designated location on the floor

shall be clearly marked with an adhesive tape

and a permanent marker as:

“FTTH OSP

JF DJAFa”

5. The maximum number of unit of TC-OF-SM-144

to be accommodated in the 19” Rack with

Height of 2.20m shall be FIVE (5).

CABLE

CHAMBER

MDF

ROOM OTB ROOM/

TRANSMISSION

ROOM

19”

RA

CK

H=

2200

Max.

5 x

TC

-OF

-SM

-144

FEEDER

CABLE

STO BUILDING

CABLE RACK

Page 42: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 42 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

5. HIGH-RISE BUILDING (HRB) DESIGN

No. Designator ApplicationNo. of Splitter

(Max.)

Number of PortHome Pass

Accommodated (80%)In Out Total

1. ODC for HRB/MDU (Approx.)

1.1 ODC-HRB-180 (*) Cabinet/ Wall 1:4 x 36 36 144 180 900

1.2 ODC-HRB-240 (*) Cabinet 1:4 x 48 48 192 240 1200

1.3 ODC-HRB-420 (*) Cabinet 1:4 x 84 84 336 420 2200

1.4 ODC-HRB-RACK-120 (**) 19" Rack Mount 1:4 x 24 24 96 120 600

1.5 ODC-HRB-RACK-240 (**) 19" Rack Mount 1:4 x 48 48 192 240 1200

1.6 ODC-HRB-RACK-480 (**) 19" Rack Mount 1:4 x 96 96 384 480 2500

2. ODP for HRB/MDU (Installed) (Max.)

2.1 ODP-HRB-16 (*) Wall Mount1:8 x 1 - 8 8

161:8 x 2 - 16 16

2.2 ODP-HRB-32 (*) Wall Mount1:8 x 3 - 24 24

321:8 x 4 - 32 32

3. 2-C Low Friction Indoor Cable

3.1 IC-OF-SM-1D

Distribution/ Drop-core

1-Core (G657A) Low Friction Indoor Cable for DISTRIBUTION-CABLE

3.2 IC-OF-SM-2D 2-Core (G657A) Low Friction Indoor Cable for DROP-CABLE1-Core connected with Fuse-Connect (ISC-UPC-FD), 1-Core for spare

4. ROSETTE SC Adapter

4.1 RS-IN-SC-1P 1

Indoor Rosette4.2 RS-IN-SC-2P 2 To be discussed when necessary (***)

4.3 RS-IN-SC-4P 4 To be discussed when necessary (***)

4.4 TC-MK-SC-1P 1

Indoor Rosette (Buried in wall)

4.5 TC-MK-SC-2P 2 To be discussed when necessary (***)

4.6 TC-MK-SC-4P 4 To be discussed when necessary (***)

5.1 MATERIAL FOR HRB SOLUTION

Note (*): New Item (Specifications have been accepted by TELKOM)

(**): New Item (Specifications shall be subject to concurrence by TELKOM)

(***): To be discussed with DBB TELKOM when 2P or 4P Rosette is required by the Developer

Page 43: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 43 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1-Core Low Friction Indoor Cable for

1x 1:8 Splitter with Field Installable SC Connector

(Fuse-connect) x 1pc at both ends

ODC-HRB-

1) 180

2) 240

3) 420

ODC-HRB-RACK-

1) 120

2) 240

3) 480

Feeder Cable:

1) For ODC-HRB-180: 24/48C

2) For ODC-HRB-240: 48C

3) For ODC-HRB-480: 96C

ODP:

1) ODP-HRB-16: Up to 16 HP (1or 2 x 1:8 Splitter)

Size: H=330 x W=260 x D=130

2) ODP-HRB-32: Up to 32 HP (3 or 4 x 1:8 Splitter)

Size: H=412 x W=312 x D=140

ODP-

HRB

Cable Tray/Shaft/Ladder

Rosette: TC-MK-SC-xP

(1-Port/2-Port/4-Port)

2-Core Low Friction Indoor Cable

with Field Installable SC Connector

(Fuse-connect) x 1pc at both ends

ODP-

HRB

4) For ODC-HRB-RACK-120: 24C

5) For ODC-HRB-RACK-240: 48C

6) For ODC-HRB-RACK-480: 96C

5.2 DESIGN CONCEPT FOR HRB SOLUTION

DESIGN CONCEPT FOR HRB

1. ODC shall be selected among all types

according to the site situation as well as

number of Home Pass of the target

building.

2. ODP shall be selected among three (3)

types according to the number of Home

Pass and the Floor Layout.

3. 2-Core Low Friction Indoor Cable shall

be used between ODC and ODP.

4. One (1) Low Friction Indoor Cable shall

be connected ODC Port with one (1) 1:8

Splitter of ODP i.e.:

1) ODP-HRB-16: One (1) or two (2) Low

Friction Indoor Cable:

a. 1 x 1:8 Splitter: 1 Low Friction Cable

b. 2 x 1:8 Splitter: 2 Low Friction Cables

2) ODP-HRB-32: Three (3) or four (4) Low

Friction Indoor Cables:

a. 3 x 1:8 Splitter: 3 Low Friction Cables

b. 4 x 1:8 Splitter: 4 Low Friction Cables

Page 44: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 44 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

5.3 Type of ODC for High-Rise-Building

1) CABINET TYPE 2) RACK MOUNT TYPE

(To be mounted in the Closed Rack H=1.20m)

H= 770

W=555

D=310

ODC-HRB-180

Application: Wall/Floor

D=360

H= 1450

W=750

ODC-HRB-240/420

Application: Floor

W=428

H= 275

D=302.3

ODC-HRB-RACK-120

Application: 19" Rack

W=428

D=302.3H= 445

ODC-HRB-RACK-240

Application: 19" Rack

W=428

D=302.3

H= 890

ODC-HRB-RACK-480

Application: 19" Rack

Page 45: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 45 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

5.4 Example of Cable Tray/Trunking

1) HORIZONTAL RUN

(a) On the Cable Tray

Cable Tray

Cable Trunking

(b) Direct Attachment to the Building Wall

2) VERTICAL RUN

ODP-

HRB

Elbow (Flat Angle)

T-Joint

Cable Trunking

Page 46: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 46 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

5.5 SAMPLE DESIGN: SKEMA DISTRIBUSI

ODC ABC BUILDING

F.../STO/HRB-xxx

xx PS 1:4 (xxx HP)

S 6 +++++

E 106 +++...

x IC-OF-SM-1D __mx IC-LF-OF-SM-1D __m

x IC-OF-SM-1D __m

2 IC-OF-SM-1D__m

x IC-LF-OF-SM-1D __m

1 IC-LF-OF-SM-1D __m 2 IC-OF-SM-1D __m

x IC-OF-SM-1D __m

x IC-OF-SM-1D __m

F//P01-02/1/2

ODP-HRB-16

F//P03/2/1

ODP-HRB-16

(Note: Not "8")

ODC No.

Code STO

"HRB"-"Capacity"

180

240

420

No. of Splitter No. of Home Pass

No. of Splitter 1:8

ODP No.

ODC Port No.

Each No. to be given for Each 1-Core

Indoor CableODC No.

Specify "Tower" and/or

"Shaft" according to the

Building Layout.

F//P04-05/3/2

ODP-HRB-16

2: No. of Indoor Cable to be installed and

terminated to ODP

__m: Cable Length from ODC to ODP

Tower A/

Shaft No.1

Floor-xx

Floor-yy

Floor-zz

Descriptions for ODC

1.1.1.1.ODC XXX (Name of Building)

2. F... /STO /HRB-(RACK)-xxx

3. xx PS 1:4 (xxx HP)

4. Coordinates

1. F+/ P-03/ 2/ 1

Descriptions for ODP

2. ODP-HRB-xx

Type of ODP: ODP-HRB-16, 32 (See Note above.)

Note:

Type of ODP-HRB is 2:

1. ODP-HRB-16: No. of 1:8

Splitter= 1 or 2

2. ODP-HRB-32: No. of 1:8

Splitter= 3 or 4

Page 47: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 47 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

5.6 SAMPLE DESIGN: PETA LOKASI DISTRIBUSI

1) PETA LOKASI KABEL DISTRIBUSI (Vertical View)

Tower A

F//P03/2/1

ODP-HRB-16

Note: Not "8"

F//P04-05/3/2

ODP-HRB-16

ODC ABC BUILDING

F.../STO/HRB-xxx

xx PS 1:4 (xxx HP)

F//P01-02/1/2

ODP-HRB-16

Cable Shaft No.1 Cable Shaft No.2

Cable Tray/Trunking to be installed

e.g. Cable Tray W=100mm x 35m

1

LEGEND

: ODC-HRB

: ODP-HRB

: Cable Tray/Trunking

(New)

2

: Rosette (1-Port)

: Rosette (2-Port)

: Cable Tray/Trunking

(Existing)

Page 48: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 48 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2 31

LIFT

11

4 5 6 7 8 9 10

19

31

22

32 33 34 35 36 37 38 3930

18

23

17

24

16

25

15

26

14

27

13

28

11 1

1 1

1

1 1 1 1 1

1 1 1 1 1 1

12 20

2129

F//P01-02/1/2

ODP-HRB-16

F//P03/2/1

ODP-HRB-16

Note: Not "8"

F//P04-05/3/2

ODP-HRB-16

2) PETA LOKASI DROP-CORE (Floor Plan)

Page 49: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 49 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Table-1: List of Port Management

ODC Port

No.

Distribution

Cable No.

ODPUnit No.

Drop Cable

Length (m)No./Floor Splitter No. Port

1 D01

8

1

1 1 30.0

2 2 18.0

3 3 10.0

4 25 55.0

5 26 50.0

6 27 45.0

7 28 40.0

8 29 35.0

2 D02 2

1 11

12

30

31

32

33

34

35

6

7

8

3) LIST OF PORT MANAGEMENT & DROP-CORE LENGTH

Page 50: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 50 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Page 51: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 51 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.1 PONDASI ODC-C-144 Splitter

Keterangan:

Pondasi dan lantai kerja berlapis keramik.

1. Pondasi: Keramik 20 x 20, warna biru

2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biru

310mm

1035m

m

555mm

463

170

500

600

660

360150 150

ODC Foundation: A-A

(Not to scale/ Unit: mm)

98.5 98.5

75 – 85mm

Drill:Ф14mm/ d= 75 – 85mm(Expansion Bolt: M8 x 150)

1100

463

G.L

52.5 52.5555

ODC Foundation: B-B

(Not to scale/ Unit: mm)

440

150 150140

115 115170

75 – 85mm

Drill:Ф14mm/ d= 75 – 85mm

(Expansion Bolt: M8 x 150)

G.L

31065 65

ODC Foundation: Top View

(Not to scale/ Unit: mm)

150

150

140

440

150 150360

660

440

135

135

170

660

98.598.5

463

Drill:Ф14mm/ d= 75 – 85mm

A A

B

B

(Expansion Bolt: M8 x 150)

ODC Foundation

Conduit Connection

(Not to scale/ Unit)

R > 500mm

W=600

(HH-2)

Handhole

Type:HH2

5 x HDPE 33/40

(B-B Side)

Approx.30cm or less

Approx. 30cm

G.L.

- 200

± 0

- 1500

- 1000

Handhole

Type:HH-80

W=800

(HH-80)

- 600

Special Attention:

Cable Slack shall be placed only in

HANDHOLE/HH-PIT and never be

located in the ODC Foundation.

Page 52: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 52 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.2 PONDASI ODC-C-288 Splitter

150

150

140

440

165 165520

850

440

120

120

200

850

119 119612

Drill:Ф18mm/ d= 60 – 80mm

ODC Foundation: Top View

(Not to scale/ Unit: mm)

A A

B

B

(Expansion Bolt: M12 x 150)

320mm

1450m

m

750mm

ODC Mount and

Location of Anchor

Bolt

612

200

ODC Foundation: A-A

(Not to scale/ Unit: mm)

G.L

500

600

850

520165 165

119 119

60 – 80mm

Drill:Ф18mm/ d= 60 – 80mm

(Expansion Bolt: M12 x 150)

1100

612

50 50750

Keterangan:

Pondasi dan lantai kerja berlapis keramik.

1. Pondasi: Keramik 20 x 20, warna biru

2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biruODC Foundation: B-B

(Not to scale/ Unit: mm)

440

150 150

120 120200

60 – 80mm

Drill:Ф18mm/ d= 60 – 80mm

(Expansion Bolt: M12 x 150)G.L

60 60320

140

Conduit Connection

(Not to scale/ Unit)

R > 500mm

W=600

(HH-2)

Handhole

Type:HH2

5 x HDPE 33/40

(B-B Side)

Approx.30cm or less

Approx. 30cm

G.L.

- 200

± 0

- 1500

- 1000

Handhole

Type:HH-80

W=800

(HH-80)

- 600

ODC Foundation

Special Attention:

Cable Slack shall be placed only in

HANDHOLE/HH-PIT and never be

located in the ODC Foundation.

Page 53: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 53 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

500

100 300 100

TELKOM

500

100

100

300

Ф 300

PVC 4"

Sub-duct BIG

500

700

200

150

150

100

100

Distance in accordance with

the site situation.

Jarak sesuai kondisi lapangan.

150 150400

700

900

100 100

Sub-duct BIG

PVC 4"

PVC 4" for

Drop Cable

L=300

PVC 4" for

Distribution Cable

L=300

450

150

900

600150 150

150

600

150

900

700

150

500

200150 150

100 100

150

100

80

220

H(*

)600-H

600

500100 100Ф 300

150 150400

700

LARGE RADIUS ELBOW

PVC 4"

(WAVIN D-LL 4" or Equivalent)

PV

C 4

" L=

±650

Distance in accordance with

the site situation.

Jarak sesuai kondisi lapangan.

6.3 PONDASI ODP PEDESTAL & HH-PIT-60

Cable Installation Method between HH-PIT-60 and ODP

Distribution Cable Installation

shall cautiously be carried out

so that the Bending Radius of

20cm shall be secured.

Note “H”: Height above ground

shall be minimum 10cm. Actual

height shall be in accordance

with the site condition.

Page 54: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 54 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1300

250

150

900

250 1000

1250

288-C cable

R= 44.2mm

+- 150cm

557mm

450625 625

1700

1300

250

150

+-

90cm

450625 625

PASS-THROUGH CLOSURE ARRANGEMENT IN HH-1

(288-C Loose Tube Cable / 3M Type 2178LS)

BESI 70 x 50 x 3

150 1501250

1550

100 1001350

200 200950

1550

Hole Ф20mm

Ф10mm x 125mm

POT B - B

Ф12mm x 125mm

PVC Ф4" x 4

L= 300

1

5

0

1

5

0

1

5

01

5

0

Ф10mm x

125mm

BETON: 225kg/cm²

150 1501700

2000

200

150

1300

1650

600 600100 100

200 200 200200 200 200

Ф10mm x 125mm

Ф10mm x 125mm

POT A - A

600

200 200 200

Ф12mm x 125mm

150

150

L=300

T

E

L

K

O

M

T

E

L

K

O

M

T

E

L

K

O

M

150

150

150

950

1550

A A

B

B

100200200200 200 200200

2000

200 200100

1350

3 x 600 = 1800

150

TE

LK

OM

200

TE

LK

OM

TE

LK

OM

6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300)

Page 55: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 55 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

BESI 70 x 50 x 3

150 150600

900

100 100700

150 150400

900

Hole

Ф20mm

Ф10mm x 125mm

POT B - B

PVC Ф4" x 4

L= 300

150

150150

150

T

E

L

K

O

M

100 225 225 100200 225225 200

1500

150

150

150

300

900A A

B

B

T

E

L

K

O

M

2 x 650 = 1300

700

150

PVC Ф4" x 4

L= 300

150 1501200

1500

200

150

1300

1650

650 650100 100

225 200 225225 200 225

150

Ф10mm x 125mm

Ф10mm x 125mm

POT A - A

150

L=300

6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300)

BETON: 225kg/cm²

Page 56: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 56 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800)

150150 800

1100

150

Ф10mm x 125mm

Ф10mm x 125mm

200

150

800

1150

100

200

450

1100

125

150

L=300

450 100

125 200125 125

POT A - A

Hole Ф20mm

150

150150 PVC Ф4" x 4

L= 300

BESI 70 x 50 x 3

Ф10mm x 125mm

150 150800

1100

200

150

800

1150

1100

100 100900

150 150600

150

POT B - B

B

T

E

L

K

O

M

1100

150

100

1100

A A

B

1100

PVC Ф4" x 4

L= 300

900

T

E

L

K

O

M

150

100

600

100

125

100

200

450

1100

450

125 125 200 125

BETON: 225kg/cm²

Page 57: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 57 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

G.L.

Appro

x.

2.2

0m

10cm

30cm10c

m30cm

Appro

x.

10cm

Cla

mps s

hall

be a

ttached

Appro

x.

@

< 1

.0m

Cla

mps s

hall

be a

ttached A

ppro

x.

@

< 1

.0m

Gap between steel pipe (Ф

2") and ODP (Wall Mount)

shall be less than 10cm

Galvanized Steel Pipe (Ф2")

and Clamps shall be painted

with the same color with the

wall.

Appro

x.

10cm

Appro

x.

10cm

Appro

x.

10cmB (See detail.)

A (See

detail.)

Approx.

5cm

Gap between steel pipe (Ф

2") and ODP (Wall Mount)

shall be less than 10cm

Identification Marking

(White color) shall be

applied on the cable of

"Up-stream/ODC" side.

In case Gap between

steel pipe (Ф 2") and ODP

(Wall Mount) is more than

5cm, cables shall be

protected with spiral or

flexible pipe (Black color)

HDPE Pipe 33/40

Ф 2" Galvanized Steel Pipe

Details "A"

30cm

10cm

20cm

30cm

30cm

G.L.

HDPE 33/40 shall be

installed until the level with

Galvanized Steel Pipe..

Details "B"

6.7 INSTALLATION OF ODP WALL (1)

Page 58: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 58 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Flex. Pipe

OD=25mm

Steel flexible inside

HH PIT-60

150

Flex-pipe

R≧300

Approx.

200

Appro

x. 100

Approx. 100

Approx. 100

Flex-pipe R≧300

Flex-pipe

R≧300

Flex-pipe

R≧300

Flex-pipe

R≧300

PVC Simple

Socket for OD

25mm Pipe

PVC/High-Impact

Conduit OD Ф25mm

PVC/High-Impact

Conduit OD Ф25mm

Pipes shall be buried in the wall.

Pipe space shall be filled with

concrete after ODP installation.

150

Approx.

200

100

50

Approx.

100

HH PIT-60

Note:

In case when pipes shall be buried in the building wall due to the

requirement by the developer, the following points shall be taken into

account for the installation.

1. HH-PIT-60 shall be installed in front of ODP location.

2. Flexible Pipe with steel (OD 25mm) shall be used at the bending part of

conduit.

3. Bending Radius of Flexible Pipe shall be more than 300mm.

4. PVC/High-Impact Pipe (OD 25mm) shall be used at the straight part of

conduit.

5. PVC Simple Socket for OD 25mm Pipe shall be used at all jointing part.

6. Pipe space of wall shall be filled with concrete after installation of ODP.

(ODP termination work shall be done prior to the pipe fixing and concrete

work.)

7. The wall shall be restored to the original condition and painted with the

same color with the original wall.

MOM/BA shall be made (to be signed by the PIC of the developer) for the

confirmation of the requirement.

2 x PVC Ф50

(L=200)

Pipes shall be buried in the wall.

Pipe space shall be filled with

concrete after ODP installation.

Drop Cable

6.7 INSTALLATION OF ODP WALL (2)(In case pipe shall be buried in the wall)

Page 59: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 59 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.8 FORM FOR CORE ASSIGNMENT

6.8.1 FEEDER CABLE (STAR TOPOLOGY: 24 CORE BASE)

Page 60: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 60 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.8.2 FEEDER CABLE (STAR TOPOLOGY: 12 CORE BASE)

Page 61: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 61 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.8.3 FEEDER CABLE (RING TOPOLOGY)

Page 62: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 62 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.8.4 DISTRIBUTION CABLE

No. Port No. PORT No.

CORE ASSIGNMENT DIAGRAM (DISTRIBUTION CABLE)CAPACITY -CORE

OTBPort No.

SPLITTER 1:4CORE No.

ODCPORT No.

ODC TRAY

DISTRIBUTION CABLE No.

4

3

4

1

2

D-

2

3

4

1

2

3

4

1

2

3

3

4

1

2

3

4

1

2

1

19

20

21

22

23

24

13

14

15

16

17

18

7

8

9

10

11

12

1

2

3

4

5

6

FEEDER SEGMENT

1

2

3

4

1

2

3

4

5

6

7

8

9

10

STO

11

12

5

6

7

8

DISTRIBUTION SEGMENT

ODP No.ODP No.ODP No.ODP No.

NAMA LOKASI

9

10

11

12

Page 63: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 63 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Tipe Product : O

DC

-C-144

Tgl. Instalasi

Nam

a Lokasi

Nam

a Installer

Category

Items

1. AksesorisC

able band (M)

Cable band (L)

Spiral Tube

Com

pound

Cable tie

Assembly m

anual

PVC

tape

2. Pondasi O

DC

Baut expansion tidak kendur

3. Lubang Kabel M

asuk (Feeder & D

istribusi)

4. Cable clam

pC

lamp untuk tension M

ember tidak kendur

Cable B

and tidak Kendur

5. Rute Loose Tube

Tidak ada small bending (diam

eter > 60)

tidak terjepit dengan tutup tray

Tidak ada small bending (diam

eter > 60)

tidak terjepit dengan tutup tray

7. Rute P

igtail dalam Tray

Arah Rute (bentuk S

)

Tidak ada small bending (diam

eter > 60)

tidak terjepit dengan tutup tray

8. Instalasi Splitter m

odul

rute sesuai petunjuk manual

Tidak ada small bending (diam

eter > 60)

tidak saling tersangkut dan mudah di urai

10. SC

connector patchingK

onektor tercolok dengan benar (sampai bunyi klik)

diperiksa oleh :

(Site m

anager)

Catatan

Arah dan Posisi S

plitter harus benar (Input :bawah;

Output :atas)

Penggunaan C

ompound harus rapat (tidak ada celah)

Installation Check S

heet

pcs

pcs

pcspc

pcs

9. Rute kabel dari S

plitter ke Tray

pcpc

Check

* 2 buah kunci OD

C harus sudah

diterima site m

anager

* cek sisa aksesoris yang diperlukan

untuk instalasi kabel berikutnya dan untuk

maintenance

6. Rute Fiber didalam

Tray

6.9 INSTALLATION CHECK SHEET

6.9.1 INSTALLATION CHECK SHEET: ODC-C-144

Page 64: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 64 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.9.2 INSTALLATION CHECK SHEET: ODC-C-288Tipe P

roduk : OD

C-C

-288

Tgl. Instalasi

Nam

a Lokasi

Nam

a Installer

Category

Items

1. AksesorisC

able band (M)

Cable band (L)

Spiral Tube

Com

pound

Cable tie

Assembly m

anual

PVC

tape

2. Pondasi O

DC

Baut expansion tidak kendur

3. Lubang Kabel M

asuk (Feeder & D

istribusi)

4. Cable clam

pC

lamp untuk tension M

ember tidak kendur

Cable B

and tidak Kendur

5. Rute Loose Tube

Tidak ada small bending (diam

eter > 60)

tidak terjepit dengan tutup tray

Tidak ada small bending (diam

eter > 60)

tidak terjepit dengan tutup tray

7. Rute P

igtail dalam Tray

Arah Rute (bentuk S

)

Tidak ada small bending (diam

eter > 60)

tidak terjepit dengan tutup tray

8. Instalasi Splitter m

odul

rute sesuai petunjuk manual

Tidak ada small bending (diam

eter > 60)

tidak saling tersangkut dan mudah di urai

10. SC

connector patchingK

onektor tercolok dengan benar (sampai bunyi klik)

Diperiksa oleh

(Site m

anager)

Catatan

Arah dan Posisi S

plitter harus benar (Input : kiri ;

Output : kanan)

* 2 buah kunci OD

C harus sudah

diterima site m

anager

Installation Check S

heet

Checkpcs

pcs

pcspc

pcs

* cek sisa aksesoris yang diperlukan

untuk instalasi kabel berikutnya dan untuk

maintenance

6. Rute Fiber didalam

Tray

9. Rute kabel dari S

plitter ke Tray

pcpc

Penggunaan C

ompound harus rapat (tidak ada

celah)

Page 65: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 65 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Product Type : O

DP

-CA-8/16-W

P

Installation Date :

Installation Site :

Installer Nam

e :

Category

Items

Check

1. AccessoryC

able tiepcs

Expansion screw

sets

Drop cable fixing clam

ppcs

Buku m

anualpc

PVC

tapepc

2. Instalasi Splitter

Arah : input : kiri ; output : kanan , label terlihat

Posisi S

plitter : No1 paling atas

Tidak ada small bending (diam

eter > 60)

Kabel Tidak terjepit atau tersangkut jika dibuka

Posisi K

onektor

4. Lubang Tempat kabel m

asuk

5. clamp K

abelC

lamp untuk Tension m

ember Tidak kendur

Clam

p untuk kabel tidak kendur

6. Rute kabel S

CP

T Pass through

Tidak ada small bending (diam

eter > 60)

Tidak terjepit dan tersangkut jika OD

P dibuka

7. Clam

p dan rute SC

PT yang di term

inasipastikan penggunaan kabel Ties di tiga titik

Tidak ada small bending (diam

eter > 60)

tidak terjepit dan tersangkut jika OD

P dibuka

8. Rute Fiber setelah S

plicingTidak ada sm

all bending (diameter > 60)

tidak terjepit dan tersangkut jika OD

P dibuka

Diperiksa oleh :

(Site m

anager)

Catatan

pemasangan tem

pat masuk kabel harus rata, tidak m

iring

Installation Check sheet

* 1 buah kunci OD

P harus sudah

diterima site m

anager

tidak ada celah (penggunaan solasi atau gromm

et

harus dapat menutup celah)

ada disebelah kanan,

Baris konektor paling baw

ah untuk Splitter no.1

* cek sisa aksesoris yang diperlukan

untuk instalasi kabel berikutnya dan untuk

maintenance

3. instalasi output Splitter pada panel

Adapter

6.9.3 INSTALLATION CHECK SHEET: ODP-PL/PW-8/16

Page 66: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 66 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Product Type : TC-SM

-144

Installation Date :

Installation Site :

Installer Name :

Category

Items

1.AksesorisC

able band (M)

Cable band (L)

Plastic Tube

Screw and nut

Cable tie

Buku Manual

PVC tape

2. Clam

p kabelC

lamp untuk Tension m

ember Tidak kendur

Cable Band tidak kendur

3. Rute kabel Loose tube

Tidak ada small bending (diam

eter > 60)

kabel Tidak terjepit atau tersangkut jika tray dilepas

Tidak ada small bending (diam

eter > 60)

Tidak terjepit atau tersangkut jika cover tray di buka

5. Rute Pigtail pada Tray

Rute m

embentuk huruf S

Tidak ada small bending (diam

eter > 60)

Tidak Terjepit atau tersangkut jika cover tray dibuka

Diperiksa oleh

(Site manager)

Catatan

pcpc

Check

4. Rute kabel dalam

tray

* Cek sisa aksesoris yang diperlukan

untuk instalasi kabel berikutnya dan untuk

maintenance

Installation Check Sheet

pcs

pcs

pcs

sets

pcs

6.9.4 INSTALLATION CHECK SHEET: TC-SM-144

Page 67: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 67 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (1/6)A

KA

BE

L &

PE

NY

AM

BU

NG

AN

1D

C-O

F-S

M-12D

Pengadaan dan pem

asangan Kabel D

uct Fiber O

ptik

Single M

ode 12 core G 652 D

(termasuk perijinan

PE

MD

A, P

U, W

arga)

meter

2D

C-O

F-S

M-24D

Idem 24 core

meter

3D

C-O

F-S

M-48D

Idem 48 core

meter

4D

C-O

F-S

M-96D

Idem 96 core

meter

5D

C-O

F-S

M-144D

Idem 144 core

meter

6D

C-O

F-S

M-288D

Idem 288 core

meter

7D

C-O

F-S

M-432D

Idem 432 core

meter

8D

C-O

F-S

M-960D

Idem 960 core

meter

9A

C-O

F-S

M-12D

Pengadaan dan pem

asangan Kabel U

dara Fiber

Optik S

ingle Mode 12 core G

652 D (term

asuk

perijinan PE

MD

A, P

U, W

arga)

meter

10A

C-O

F-S

M-24D

Idem 24 core

meter

11A

C-O

F-S

M-48D

Idem 48 core

meter

12A

C-O

F-S

M-96D

Idem 96 core

meter

13D

C-O

F-S

M-12C

Pengadaan dan pem

asangan Kabel D

uct Fiber O

ptik

Single M

ode 12 core G 655 C

(termasuk perijinan

PE

MD

A, P

U, W

arga)

meter

14D

C-O

F-S

M-24C

Idem 24 core

meter

15D

C-O

F-S

M-48C

Idem 48 core

meter

16D

C-O

F-S

M-96C

Idem 96 core

meter

17A

C-O

F-S

M-12C

Pengadaan dan pem

asangan Kabel U

dara Fiber

Optik S

ingle Mode 12 core G

655 C (term

asuk

perijinan PE

MD

A, P

U, W

arga)

meter

18A

C-O

F-S

M-24C

Idem 24 core

meter

19A

C-O

F-S

M-48C

Idem 48 core

meter

20A

C-O

F-S

M-96C

Idem 96 core

meter

21D

C-O

F-S

M-8-S

C

Pengadaan dan pem

asangan Kabel D

uct Fiber O

ptik

Single M

ode 8 core G 652 D

, "Easy to split"

(termasuk perijinan P

EM

DA

, PU

, Warga)

meter

22D

C-O

F-S

M-12-S

CIdem

12 Core

meter

23D

C-O

F-S

M-24-S

CIdem

24 Core

meter

24A

C-O

F-S

M-8-S

C

Pengadaan dan pem

asangan Kabel U

dara Fiber

Optik S

ingle Mode 8 core G

652 D, "E

asy to split"

(termasuk perijinan P

EM

DA

, PU

, Warga)

meter

25A

C-O

F-S

M-12-S

CIdem

12 Core

meter

26A

C-O

F-S

M-24-S

CIdem

24 Core

meter

27S

C-O

F-S

M-24

Pengadaan dan pem

asangan alat sambung (cabang/

lurus) untuk Fiber O

ptik kapasitas 12 - 24 corepcs

28S

C-O

F-S

M-48

Idem 12 - 48 core

pcs

29S

C-O

F-S

M-96

Idem 12 - 96 core

pcs

30S

C-O

F-S

M-144

Idem 12 - 144 core

pcs

31S

C-O

F-S

M-288

Idem 12 - 288 core

pcs

32O

S-S

M-1 E

ksP

enyambungan K

abel Optik S

ingle Mode kap 1 core

dengan cara fusion splicecore

33O

S-S

M-6

Penyam

bungan Kabel O

ptik Single M

ode kap 6 core

dengan cara fusion splicepcs

34O

S-S

M-12

Idem kap 12 core

pcs

35O

S-S

M-24

Idem kap 24 core

pcs

36O

S-S

M-48

Idem kap 48 core

pcs

37O

S-S

M-96

Idem kap 96 core

pcs

38O

S-S

M-144

Idem kap 144 core

pcs

39O

S-S

M-288

Idem kap 288 core

pcs

40A

B-O

F-S

M-2D

Pengadaan dan pem

asangan Air B

lown C

able Optik,

Single M

ode 2 core, G 652 D

(termasuk perijinan

PE

MD

A, P

U, W

arga)

meter

41A

B-O

F-S

M-4D

Idem 4 core

meter

42A

B-O

F-S

M-8D

Idem 8 core

meter

43A

B-O

F-S

M-12D

Idem 12 core

meter

44A

B-O

F-S

M-24D

Idem 24 core

meter

45A

B-O

F-S

M-48D

Idem 48 core

meter

46A

B-O

F-S

M-72D

Idem 72 core

meter

47A

B-O

F-S

M-96D

Idem 96 core

meter

48A

B-O

F-S

M-144D

Idem 144 core

meter

49G

C-O

F-S

M-1D

Pengadaan dan pem

asangan Drop C

able FO

Duct

/under ground 1 Core S

ingle Mode, G

.657m

eter

50G

C-O

F-S

M-2D

idem 2 core

51H

C-O

F-S

M-1D

Pengadaan dan pem

asangan Drop C

able FO

atas

tanah /aerial 1 Core S

ingle Mode, G

.657m

eter

52H

C-O

F-S

M-2D

idem 2 core

meter

53IC

-OF

-SM

-1DP

engadaan dan pemasangan Indoor C

able FO

Single

Mode 1 core, G

.657m

eter

54IC

-OF

-SM

-2DIdem

2 corem

eter

KE

TE

RA

NG

AN

NO

DE

SIG

NA

TO

RU

RA

IAN

PE

KE

RJA

AN

SA

TU

AN

Page 68: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 68 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (2/6)55

PC

-SC

-2-BI

Patch cord 2 m

eter, Bend Insensitive (S

C/A

PC

To

SC

/UP

C) dari R

oset ke ON

T, G.657

pcs

56P

C-S

C-5-B

IP

atch cord 5 meter, B

end Insensitive (SC

/AP

C To

SC

/UP

C) dari R

oset ke ON

T, G.657

pcs

57P

C-S

C-2

Patch cord 2 m

eter, (SC

/AP

C To S

C/A

PC

), G.657

pcs

58P

C-S

C-5

Patch cord 5 m

eter (SC

/AP

C To S

C/A

PC

), G.657

pcs

59P

C-S

C-10

Patch cord 10 m

eter (SC

/AP

C To S

C/A

PC

), G.657

pcs

60P

C-S

C-20

Patch cord 20 m

eter (SC

/AP

C To S

C/A

PC

), G.657

pcs

61P

C-F

C-20

Patch cord 20 m

eter (FC

/AP

C To F

C/A

PC

), G.657

pcs

62P

C-S

C-30

Patch cord 30 m

eter (SC

/AP

C To S

C/A

PC

), G.657

pcs

63P

C-F

C-30

Patch cord 30 m

eter (FC

/AP

C To F

C/A

PC

), G.657

pcs

64P

C-S

C-40

Patch cord 40 m

eter (SC

/AP

C To S

C/A

PC

), G.657

pcs

65P

C-F

C-40

Patch cord 40 m

eter (FC

/AP

C To F

C/A

PC

), G.657

pcs

66P

C-S

C-2

Patch cord 2 m

eter, (SC

/UP

C To S

C/U

PC

), G.657

pcs

67P

C-S

C-5

Patch cord 5 m

eter (SC

/UP

C To S

C/U

PC

), G.657

pcs

68P

C-S

C-10

Patch cord 10 m

eter (SC

/UP

C To S

C/U

PC

), G.657

pcs

69P

C-S

C-20

Patch cord 20 m

eter (FC

/UP

C To F

C/U

PC

), G.657

pcs

70P

C-F

C-20

Patch cord 20 m

eter (SC

/UP

C To S

C/U

PC

), G.657

pcs

71P

C-S

C-30

Patch cord 20 m

eter (FC

/UP

C To F

C/U

PC

), G.657

pcs

72P

C-F

C-30

Patch cord 30 m

eter (SC

/UP

C To S

C/U

PC

), G.657

pcs

73P

C-S

C-40

Patch cord 40 m

eter (FC

/UP

C To F

C/U

PC

), G.657

pcs

74P

C-F

C-40

Patch cord 40 m

eter (SC

/UP

C To S

C/U

PC

), G.657

pcs

75P

C-F

C-40

Patch cord 40 m

eter (FC

/UP

C To F

C/U

PC

), G.657

pcs

76O

DC

-C-144 S

plitter

Pengadaan dan pem

asangan kabinet OD

C (O

utdoor)

kap 144 core dengan space untuk spliter modular

termasuk m

aterial adaptor SC

/UP

C, pigtail, pondasi

berlapis keramik, lantai kerja, patok pengam

an (5

buah), berikut pelabelan

pcs

77O

DC

-C-288 S

plitter

Pengadaan dan pem

asangan kabinet OD

C (O

utdoor)

kap 288 core dengan space untuk spliter modular

termasuk m

aterial adaptor SC

/UP

C, pigtail, pondasi

berlapis keramik, lantai kerja, patok pengam

an (5

buah), berikut pelabelan

pcs

78O

DC

-C-576 S

plitter

Pengadaan dan pem

asangan kabinet OD

C (O

utdoor)

kap 576 core dengan space untuk spliter modular

termasuk m

aterial adaptor SC

/UP

C, pigtail, pondasi

berlapis keramik, lantai kerja, patok pengam

an (5

buah), berikut pelabelan

pcs

79O

DC

-C- 48 S

plitter

Pengadaan dan pem

asangan OD

C-P

ole ( Outdoor )

with space for passive spliter, adaptor S

C/U

PC

kap

48 core, berikut pelabelan

pcs

80O

DP

-CU

-8

Pengadaan dan pem

asangan OD

P type C

losure

Underground K

ap 8 core with space for splitter,

Adapter S

C/U

PC

pcs

81O

DP

-CU

-16idem

16 corepcs

82O

DP

-CA

-8

Pengadaan dan pem

asangan OD

P type C

losure

Aerial K

ap 8 core berikut space pasive spliter (1:8),

adapter SC

/UP

C,berikut pelabelan

pcs

83O

DP

-CA

-16

Pengadaan dan pem

asangan OD

P type C

losure

Aerial K

ap 16 core berikut space 2 pasive spliter

(1:8), adapter SC

/UP

C,berikut pelabelan

pcs

84O

DP

-A-8

Pengadaan dan pem

asangan OD

P type Indoor/w

all

Kap 8 core berikut space pasive spliter (1:8), adapter

SC

/UP

C,berikut pelabelan

pcs

85O

DP

-A-16

Pengadaan dan pem

asangan OD

P type Indoor/w

all

Kap 16 core berikut space 2 pasive spliter (1:8),

adapter SC

/UP

C,berikut pelabelan

pcs

86O

DP

-A-24

Pengadaan dan pem

asangan OD

P type Indoor/w

all

Kap 24 core berikut space 3 pasive spliter (1:8),

adapter SC

/UP

C,berikut pelabelan

pcs

87O

DP

-A-48

Pengadaan dan pem

asangan OD

P type Indoor/w

all

Kap 48 core berikut space 6 pasive spliter (1:8),

adapter SC

/UP

C,berikut pelabelan

pcs

88O

DP

-PL-8

Pengadaan dan pem

asangan OD

P ( P

ilar ) kap 8

core termasuk pigtail, berikut space 1 splitter (1:8),

pelabelan.

pcs

89O

DP

-PL-16

Pengadaan dan pem

asangan OD

P ( P

ilar ) kap 16

core termasuk pigtail, berikut space 2 splitter (1:8),

pelabelan.

pcs

KE

TE

RA

NG

AN

NO

DE

SIG

NA

TO

RU

RA

IAN

PE

KE

RJA

AN

SA

TU

AN

Page 69: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 69 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (3/6)90

TC-S

M-12

Pengadaan dan P

emasangan O

TB term

asuk

terminasi dan penyam

bungan kabel optik Single

mode kap 12 core serta A

dapter (SC

Connector),

pigtail dan protection sleeve pada cassette/box

pcs

91TC

-SM

-24Idem

24 corepcs

92TC

-SM

-48Idem

48 corepcs

93TC

-SM

-72Idem

72 corepcs

94TC

-SM

-96Idem

96 corepcs

95TC

-SM

-144Idem

144 corepcs

96R

S-IN

-SC

-1PP

emasangan dan term

inasi Roset/Indoor O

ptical

Outlet w

ith SC

Adaptor - kap 1 port berikut pigtail

pcs

97R

S-IN

-SC

-2Pidem

2 portpcs

98R

S-IN

-SC

-4Pidem

4 portpcs

99TC

-MK

-SC

-1PR

oset Optik M

odular Keystone ( D

itanam ditem

bok )

dengan SC

Adaptor kap 1 port

unit

100TC

-MK

-SC

-2Pidem

2 portunit

101TC

-MK

-SC

-4Pidem

4 portunit

102P

S-1-2-O

DC

Pengadaan dan pem

asangan Passive S

plitter 1:2,

type modular, for O

DC

, termasuk pigtail

pcs

103P

S-1-4-O

DC

Idem, 1 : 4

pcs

104P

S-1-8-O

DC

Idem, 1 : 8

pcs

105P

S-1-16-O

DC

Idem, 1 : 16

pcs

106P

S-1-32-O

DC

Idem, 1 : 32

pcs

107P

S-1-2-O

DP

Pengadaan dan pem

asangan Passive S

plitter 1:2,

type PLC

/Modular, for O

DP

, termasuk adaptor

pcs

108P

S-1-4-O

DP

Idem, 1 : 4

pcs

109P

S-1-8-O

DP

Idem, 1 : 8

pcs

110P

S-1-16-O

DP

Idem, 1 : 16

pcs

111P

S-1-32-O

DP

Idem, 1 : 32

pcs

112P

S-2-2-O

DC

Pengadaan dan pem

asangan Passive S

plitter 2:2,

type modular, for O

DC

, termasuk pigtail

pcs

113P

S-2-4-O

DC

Idem, 2 : 4

pcs

114P

S-2-8-O

DC

Idem, 2 : 8

pcs

115P

S-2-16-O

DC

Idem, 2 : 16

pcs

116P

S-2-32-O

DC

Idem, 2 : 32

pcs

117P

S-2-2-O

DP

Pengadaan dan pem

asangan Passive S

plitter 2:2,

type PLC

/Modular, for O

DP

, termasuk adaptor

pcs

118P

S-2-4-O

DP

Idem, 2: 4

pcs

119P

S-2-8-O

DP

Idem, 2 : 8

pcs

120P

S-2-16-O

DP

Idem, 2 : 16

pcs

121P

S-2-32-O

DP

Idem, 2 : 32

pcs

122S

ITAC

OD

CA

kuisisi Lahan SITA

C O

DC

Node

123P

U-S

7.0-140

Pengadaan dan P

emasangan Tiang B

esi 7 meter,

berikut cat & cor pondasi dan assesories - kekuatan

tarik 140 kg

pcs

124P

U-S

9.0-140

Pengadaan dan P

emasangan Tiang B

esi 9 meter,

berikut cat & cor dan assesories -kekuatan tarik 140

kg

pcs

125P

U-C

9.0-300P

engadaan dan Pem

asangan Tiang Beton 9 m

eter,

berikut assesories

126G

U-G

Pengadaan dan P

emasangan Tem

berang Tarikpcs

127P

U-S

B-7.0-140

Pengadaan dan pem

asangan temberang sokong 7

meter, kekuatan tarik 140 kg

pcs

128P

U-A

SA

sesoris tiang eksistingset

129G

B-G

1P

engadaan dan Pem

asangan Grounding 1 titik rod

pada OD

P /kotak pem

bagi dengan maks 3 ohm

pcs

130G

B-G

3P

engadaan dan Pem

asangan Grounding 3 titik rod

pada OD

C dengan m

aks 1 ohmpcs

131G

rounding di Eksisting

Pengadaan dan P

emasangan m

aterial Grounding di

lokasi gedung eksisting dengan cara integrasipcs

132TC

-XX

-OD

C

Pengaddaan dan P

emasangan R

ise Pipe untuk

pengaman kabel optik ke O

DC

Pole / titik naik K

U

diamater 1 panjang 3 m

eter

pcs

133TC

-OF

-R-19

Pengadaan dan pem

asangan rak kabel 19 inch untuk

Fiber O

ptik Closed R

ack, 2,2 Mtr

pcs

134F

LEX

-PIP

EP

engadaan dan pemasangan F

lexible pipe (pipa

spiral) ukuran 1.5 inch termasuk aksesoris.

meter

KE

TE

RA

NG

AN

NO

DE

SIG

NA

TO

RU

RA

IAN

PE

KE

RJA

AN

SA

TU

AN

Page 70: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 70 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

135 P

P-O

F-IN

Pengadaan dan P

emasangan P

ipe Protector Indoor

Cable (P

VC

White) H

igh Impact C

onduit 20 mm

meter

136 P

P-O

F-O

UT

Pengadaan dan P

emasangan P

ipe Protector

Outdoor C

able ( PV

C B

lack) High Im

pact Conduit 20

mm

meter

137TC

-OF

-DC

-10P

engadaan dan pemasangan D

uct Cable untuk

Route K

abel menuju R

oset, 10x20 mm

meter

138TC

-OF

-DC

-20idem

20x40 mm

meter

139TC

-OF

-CR

-100P

engadaan dan pemasangan Tray C

able, Lebar 100

mm

tebal 5 mm

Alum

unium disesuaikan kebutuhan

meter

140TC

-OF

-CR

-200idem

200 mm

meter

141TC

-OF

-CR

-300idem

300 mm

meter

142D

D-S

3-1

Pengadaan dan pem

asangan Pipa B

esi Diam

eter

Dalam

100 mm

dan ketebalan pipa 3,65 mm

untuk

crossing 1 pipa

meter

143D

D-S

3-2

Pengadaan dan pem

asangan Pipa besi diam

eter

dalam 100 m

m dan ketebalan pipa 3,65 m

m untuk

crossing 2 pipa

meter

144D

D-S

3-3

Pengadaan dan pem

asangan Pipa besi diam

eter

dalam 100 m

m dan ketebalan pipa 3,65 m

m untuk

crossing 3 pipa

meter

145D

D-V

4-1

Pengadan dan P

emasangan P

ipa Duct dengan

pengecoran diameter dalam

100 mm

, ketebalan 4

mm

, 1 pipa

meter

146D

D-V

4-2Idem

, 2 pipam

eter

147D

D-V

5-1P

emasangan P

ipa Duct dengan pasir dia 100 m

m , 1

pipa ( crossing )m

eter

148D

D-V

5-2Idem

, 2 pipam

eter

149D

D-D

A-S

1

Pengadaan dan pem

asangan pipa Duct m

enempel

pada jembatan m

enggunakan Pipa G

alvanis

diamenter dalam

100 mm

, tebal 3,65 mm

, 1 pipa

meter

150D

D-B

SS

-S1

Pengadaan dan pem

asangan pipa Duct pada

jembatan dengan m

enempel m

enggunakan Pipa besi

Galv 1 pipa (P

arit)

meter

151D

D-B

TS-S

1P

engadaan dan pemasangan P

ipa Duct dengan

penguat sendiri 1 pipam

eter

152D

D-B

TS-S

2P

engadaan dan pemasangan P

ipa Duct dengan

penguat sendiri 2 pipam

eter

153H

B-P

S-1

Pengadaan dan pem

asangan Pipa D

uct dengan

system gantung 1 pipa bentang s/d 40 m

eterm

eter

154H

B-P

S-2

Pengadaan dan pem

asangan Pipa D

uct dengan

system gantung 2 pipa bentang lebih 40 m

eterm

eter

155D

D-B

MR

Boring pada Lintasan K

ereta Api m

enggunakan 2

pipatrack

156D

C-S

D-1

Pengadaan dan P

emasangan 1 S

ubduct 27/32 mm

pada polongan route Duct

meter

157D

C-S

D-3

Pengadaan dan P

emasangan 3 S

ubduct 27/32 mm

pada polongan route Duct

meter

158D

C-S

D-1 B

igP

engadaan dan Pem

asangan 1 Subduct B

ig pada

polongan route Duct

meter

159D

C-S

D-2 B

igP

engadaan dan Pem

asangan 2 Subduct B

ig pada

polongan route Duct

meter

160D

CD

-PV

C-1

Pem

buatan Duct C

able Distribusi diam

eter pipa PV

C

2 inc AW

1 pipam

eter

161D

CD

-PV

C-2

idem 2 pipa

meter

162D

CD

-PV

C-4

idem 4 pipa

meter

163D

D-B

M-1

Pem

asangan Pipa D

uct dengan cara boring manual

/mesin 1 pipa

meter

164D

D-B

M-2

Idem 2 pipa

meter

165D

D-B

M-H

DP

E-1

Boring m

anual/mesin untuk H

DP

E / M

icro Duct

diameter dalam

33 mm

1 pipa kedalaman 1,5 m

eterm

eter

166D

D-B

M-H

DP

E-2

Idem, 2 pipa

meter

167D

D-H

DP

E-1

Pengadaan dan P

emasangan 1 pipa H

DP

E/H

DP

E

BIG

untuk kabel FO

, Include Soket H

DP

Em

eter

168D

D-H

DP

E-2

Idem 2 pipa

169D

D-R

OD

Pem

bersihan pada route Duct yang kosong / R

odding

Duct E

xisting.m

eter

170D

D-R

V-1

Perbaikan R

oute Duct / H

DP

E, 1 pipa.

meter

KE

TE

RA

NG

AN

NO

DE

SIG

NA

TO

RU

RA

IAN

PE

KE

RJA

AN

SA

TU

AN

6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (4/6)

Page 71: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 71 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (5/6)17

1D

D-R

V-C

ON

CR

ETE

Re

locate d

an Exspa

nd P

ipa in C

ounter W

all by Bo

bok

Concrete

m3

172

BC

-TR

-0.4

Galia

n, Pengurug

an kem

bali dan pe

rbaikan kem

bali,

peng

isian p

asir, deeksten da

n tand

a rute ka

bel tanah

dan tem

pat sa

mb

ung kedalam

an 0

.4 meter

me

ter

173

BC

-TR

-0.6

Galia

n, Pengurug

an kem

bali dan pe

rbaikan kem

bali,

peng

isian p

asir, deeksten da

n tand

a rute ka

bel tanah

dan tem

pat sa

mb

ung kedalam

an 0

.6 meter

me

ter

174

BC

-TR

-5

Galia

n, Pengurug

an kem

bali dan pe

rbaikan kem

bali,

peng

isian p

asir, deeksten da

n tand

a rute ka

bel tanah

dan tem

pat sa

mb

ung kedalam

an 1

,5 meter

me

ter

175

BD

-SK

Pe

mbob

okan dan p

erbaikan D

inding untuk lubang

Sp

aring K

abe

lTitik

176

BP

-ICP

em

bobokan da

n perb

aikan Pla

fon untuk route

Indoo

r

Cable

Titik

177

SM

D-A

BS

-2A

Pe

ngad

aan dan pem

asangan A

lat Sa

mb

ung M

icro

Duct ca

bang/lurus 2 ca

bang,termasuk co

nnecto

r,gas

block & end

cap

pcs

178

SM

D-A

BS

-3Aid

em 3 cab

angpcs

179

SM

D-A

BS

-4Aid

em 4 cab

angpcs

180

DD

-MD

DI-1A

Pe

ngad

aan dan P

ema

sangan 5

/3.5m

m M

icro Duct,

Direct Insta

ll, 1 w

ay, untuk Air B

low

n kabe

l FO

term

asuk connector

me

ter

181

DD

-MD

DI-2A

Idem

2 way

me

ter

182

DD

-MD

DI-4A

Idem

4 way

me

ter

183

DD

-MD

DI-7A

Idem

7 way

me

ter

184

DD

-MD

DI-12A

Idem

12 w

ay

me

ter

185

DD

-MD

DI-19A

Idem

19 w

ay

me

ter

186

DD

-MD

DI-24A

Idem

24 w

ay

me

ter

187

DD

-MD

DI-1B

Pe

ngad

aan dan P

ema

sangan 1

0/8m

m M

icro Duct,

Direct Insta

ll, 1 w

ay, untuk Air B

low

n kabe

l FO

term

asuk connector

me

ter

188

DD

-MD

DI-2B

Idem

2 way

me

ter

189

DD

-MD

DI-4B

Idem

4 way

me

ter

190

DD

-MD

DI-7B

Idem

7 way

me

ter

191

DD

-MD

DI-1C

Pe

ngad

aan dan P

ema

sangan 1

2/10m

m M

icro Duct,

Direct Insta

ll, 1 w

ay, untuk Air B

low

n kabe

l FO

term

asuk connector

me

ter

192

DD

-MD

DI-2C

Idem

2 way

me

ter

193

DD

-MD

DI-4C

Idem

4 way

me

ter

194

DD

-MD

DI-7C

Idem

7 way

me

ter

195

DD

-MD

DB

-1A

Pe

ngad

aan dan P

ema

sangan 5

/3.5m

m M

icro Duct,

Direct B

uried, 1 way, untuk A

ir Blow

n kabel F

O

term

asuk connector

me

ter

196

DD

-MD

DB

-2AId

em 2 w

aym

eter

197

DD

-MD

DB

-4AId

em 4 w

aym

eter

198

DD

-MD

DB

-7AId

em 7 w

aym

eter

199

DD

-MD

DB

-12A

Idem

12 w

ay

me

ter

200

DD

-MD

DB

-19A

Idem

19 w

ay

me

ter

201

DD

-MD

DB

-24A

Idem

24 w

ay

me

ter

202

DD

-MD

DB

-1B

Pe

ngad

aan dan P

ema

sangan 1

0/8m

m M

icro Duct,

Direct B

uried, 1 way, untuk A

ir Blow

n kabel F

O

term

asuk connector

me

ter

203

DD

-MD

DB

-2BId

em 2 w

aym

eter

204

DD

-MD

DB

-4BId

em 4 w

aym

eter

205

DD

-MD

DB

-7BId

em 7 w

aym

eter

206

DD

-MD

DB

-1C

Pe

ngad

aan dan P

ema

sangan 1

2/10m

m M

icro Duct,

Direct B

uried, 1 way, untuk A

ir Blow

n kabel F

O

term

asuk connector

me

ter

207

DD

-MD

DB

-2CId

em 2 w

aym

eter

208

DD

-MD

DB

-4CId

em 4 w

aym

eter

209

DD

-MD

DB

-7CId

em 7 w

aym

eter

210

GB

-K-A

1G

ambar K

erta

s kalkir ukuran A1

Ha

rd C

opy &

Soft

lbr

211

GB

-L-A

1G

ambar K

erta

s lighdruk ukuran A

1lb

r

212

MH

-HIS

5P

em

buatan M

anhole Lurus T

ype H

IS5

pcs

213

MH

-HIS

5TP

em

buatan M

anhole Type

HIS

5T

pcs

214

MH

-HII S

7P

em

buatan M

anhole Type

HIIS

7pcs

215

MH

-HH

1P

em

buatan H

andho

le Typ

e HH

1pcs

216

MH

-HH

2P

em

buatan H

andho

le Typ

e HH

2pcs

217

MH

-CA

Pe

ninggian Tutup

Manhole

/Hand

hole

pcs

218

MH

-MO

DM

odifikasi M

anho

le/Ha

ndhole (sesuai lua

san)m

3

219

MH

-RS

Instalasi struktur rak da

lam m

anhole ya

ng ad

a.kg

220

HH

-PIT-60

Pe

mbua

tan HH

ukuran diam

eter da

lam (P

X L X

T =

60x4

0x60) co

r beton 1 : 2 : 3

pcs

221

HH

-PIT-40

Pe

mbua

tan HH

ukuran diam

eter da

lam (P

X L X

T =

40x4

0x40) co

r beton 1 : 2 : 3

pcs

KE

TE

RA

NG

AN

NO

DE

SIG

NA

TO

RU

RA

IAN

PE

KE

RJA

AN

SA

TU

AN

Page 72: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 72 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (6/6)

222H

H-P

IT-Portable

Pengadaan dan pem

asangan HH

Pit P

ortable

beserta aksesorisnyapcs

BN

EW

ITE

M

new

DD

-HD

PE

-Big

Pengadaan dan P

emasangan 1 pipa H

DP

E/H

DP

E

BIG

untuk kabel FO

, Include Soket H

DP

Em

eterU

NTU

K 288

new

DD

-V4-4

Pengadan dan P

emasangan P

ipa Duct dengan

pengecoran diameter dalam

100 mm

, ketebalan 4

mm

, 4 pipa

meter

OK

new

HH

-80P

embuatan H

H ukuran diam

eter dalam (P

X L X

T =

80x80x80) cor beton 1 : 2 : 3pcs

new

Cable Tray / Ladder (P

lastic) 40x40 mm

Berikut

Assesories

meter

new

Cable Tray /Ladder (P

lastic) 16x16 mm

Berikut

Assesories

meter

new

BC

-PP

Pengaddaan dan P

emasangan R

ise Pipe B

esi untuk

pengaman kabel optik / titik naik K

U dan G

rounding

diamater 1,5 inch panjang 3 m

eter

pcsO

K

new

OD

C-H

RB

-180pcs

OK

new

OD

C-H

RB

-240pcs

OK

new

OD

C-H

RB

-420pcs

OK

new

OD

P-H

RB

-16pcs

OK

new

OD

P-H

RB

-32pcs

OK

new

OD

P-S

SW

-8

Pengadaan dan pem

asangan OD

P type C

losure

Aerial (S

SW

) Kap 8 core berikut space pasive spliter

(1:8), adapter SC

/UP

C, berikut pelabelan

pcs

new

OD

P-P

W-8

Pengadaan dan pem

asangan OD

P type O

udoor/wall

Kap 8 core berikut space pasive spliter (1:8), adapter

SC

/UP

C,berikut pelabelan

pcsO

K

new

OD

P-P

W-16

Pengadaan dan pem

asangan OD

P type O

udoor/wall

Kap 16 core berikut space 2 pasive spliter (1:8),

adapter SC

/UP

C,berikut pelabelan

pcsO

K

new

OD

P-P

W-B

R-16

pcs

new

OD

P-P

L-BR

-16pcs

new

Pengukuran C

able Existing

Core

KE

TE

RA

NG

AN

NO

DE

SIG

NA

TO

RU

RA

IAN

PE

KE

RJA

AN

SA

TU

AN

Page 73: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 73 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Page 74: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 74 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Page 75: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 75 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Civil Work

FOC Laying Work

FOC Joint Work

FOC Termination Work

OTDR Measurement

Total Loss Measurement

by LS/OPM

Construction

Work

UT (PAT) UT

Pass

Fail

Work Flow to Test-Com(Internal Commissioning Test) and UT (PAT)

1. High Loss Event Detection

by OTDR 1.55um for;

1) Feeder Segment,

2) Distribution Segment

2. Fiber Length Measurement

Test-Com

(Internal Test)(for optical test on Fiber)

Preparation of OPM Test Form

Page 76: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 76 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1 2 3 4 5 6 7 8 9 1011 12

1 2 3 4 5 6 7 8 9 1011 12

1:8 splitter

1

2

3

4

5

6

7

8

1:8 splitter

1

2

3

4

5

6

7

8

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1:4

split

ter

OTB ODC ODP

No.1

ODP

No.2

Feeder

Cable

Distribution

Cable 1:8

splitter

Port#.1

1:4 splitter

Port#.1

Sp

litt

er

#.1

Port#.1

Sp

litt

er

#.1

Sp

litt

er

#.2

Port#.1 Port#.1

Feeder

CableDistribution

Cable

Typical System Cofiguration between OTB and ODP

Page 77: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 77 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Definition of Segment

OTB

fo

Feeder1:4 splitter

ODC

fo

Distribution1:8 splitter

ODPfo

Drop

Rosette ONT

BIF

patchcord

OLT

Feeder Segment Distribution Segment(Drop Segment)

Splice

SC/UPC connector

Overall Segment (OTB - ODP)

Bi-directional OTDR Measurement shall

be done upon request by TELKOM

Page 78: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 78 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Policy of Test for Optial Measurement• OTDR ; detect partially harmful waveform =only 1.55um (sensitive for fiber bend)

• LS/OPM ; for guarantee the final performance of the line

1) Feeder Segment

1-1) Measurment by OTDR with one-way to detect partially harmful event

(Bi-directional Measurement shall be done for Segment A - Segment A' upon request by TELKOM.)

1-2) Measurment by LS/OPM

2) Distribution Segment

2-1) Measurment by OTDR from ODC to ODP splitter input (one-way)

(because Handy OTDR cannot measure over 1:8 splitter)

2-2) Measurment by LS/OPM

3) Drop Segment

Measurment by LS/OPM

(Drop Segment cannot be measured by OTDR because drop cable length is <100m)

4) End to End ; Overall Section

Measurment only by LS/OPM

(because Handy OTDR cannot measure over 1:8 splitter)

Page 79: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 79 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Optical

Light

Source

NEW

Patch-cordOptical

Power

Meter

NEW Battery

KALIBRASI (Input Power Measurement)

Method of Measurement

Leave the Light Source 5 ~ 10 min. to

make the input power (Pi) stable after

switch on.

• Check Pi three (3) times at least

• Max.Pi - Min.Pi < 0.1dB

• Average Pi

Ex. Good Bad

1st - 8.20dBm -8.20dBm

2nd -8.18dBm -8.18dBm

3rd -8.22dBm -8. 07dBm

Ave -8. 20dBm

Pi = 8.20dB

DO NOT

TAKE OUT

Optical

Light Source

Optical

Power Meter

TAKE OUT

(OPM SIDE)

Prior to LS/OPM Measurement, the INPUT

POWER (Pi) shall be measured and recorded.

Page 80: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 80 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

OTBfo

Feeder1:4 splitter

ODC

Segment A'

Segment A' cannot be measured by

OTDR because 4-OTDR signal overlap

in this segment.

Optical performance of this segment

is guaranteed by Test Report of splitter

module and measurment

of Segment A by LS/OPM

OTBfo

Feeder1:4 splitter

ODC

Segment ASegment A'

OTDR

Optical Power

Meter

OTDR@1550nm

LS/OPM

@1310nm & 1550nm

Patchcord is not needed for measurment

Optial Light

Source

Segment A

1.1 Feeder Segment

Page 81: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 81 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.2 Distribution Segment-1 (SCPT and SSW; ODP installed)

fo

Distribution1:8 splitter

ODP

Segment B

ODC

Segment B'

OTDR@1550nm

LS/OPM

@1310nm & 1550nm

Segment B' cannot measure by OTDR

because 8-OTDR signal overlap in this

segment.

Optical performance of this segment is

guaranteed by Test Report of splitter

module and measurment of Segment

B by LS/OPM.

fo

Distribution1:8 splitter

ODP

Segment B

ODC

Bi-directional mesurement by ODR is not

possible because Handy OTDR cannot

measure over 1:8 splitter.

OTDR

Optial Light

Source

Optical Power

Meter

Page 82: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 82 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.3 Distribution Segment-2� SCPT/SSW CADANGAN or,

� SSW; ODP not installed, only cable installed

fo

Distribution

Segment B

ODC OTDR@1550nm

LS/OPM

@1310nm&1550nmfo

Distribution

Segment B

ODC

temporarily splice pigtail to end

of fiber

OTDR

Optial Light

Source

Optical Power

Meter

Page 83: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 83 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.4 Drop Segment

ODP

fo

Drop

Rosette

Segment C

LS/OPM

@1310nm&1550nm

Drop segment cannot be measured by

OTDR because drop cable length is

<100m.

Optial Light

SourceOptical Power

Meter

Page 84: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 84 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.5 End to End Overall (SCPT and SSW; ODP installed)

OTB

fo

Feeder1:4 splitter

ODC

fo

Distribution1:8 splitter

ODP

fo

Drop

Rosette

Segment A Segment B Segment CSegment D

LS/OPM

@1310nm & 1550nm

Note:

Overall segment cannot be measured by OTDR

because splitter is included in the line.

Optial Light

Source Optical

Power Meter

Page 85: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 85 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

1.6 Calculation of Attenuation Limit (LS/OPM Test)

Segment Calculation of Attenuation Limit Remarks

1. Feeder Cable Segment

- 1310nm A-F13= {0.35dB/km x ,.. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)}

A-F13: Attenuation Limit of Feeder Cable at 1310nm

- 1550nm A-F15= {0.215dB/km x ,.. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)}

A-F15: Attenuation Limit of Feeder Cable at 1550nm

2. Distribution Cable Segment

- 1310nm A-D13= {0.35dB/km x ,.. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)}

A-D13: Attenuation Limit of Distribution Cable at 1310nm

- 1550nm A-D15= {0.215dB/km x ,.. Km} + {0.1dB x (No. of Splice)} + {0.25dB x (No. of Connector)}

A-D15: Attenuation Limit of Distribution Cable at 1550nm

3. Drop Cable Segment

- 1310nm A-DR13= {0.35dB/km x ,.. Km} + {0.25dB x (No. of Connector)}

A-DR13: Attenuation Limit of Distribution Cable at 1310nm

- 1550nm A-DR15= {0.215dB/km x ,.. Km} + {0.25dB x (No. of Connector)}

A-DR15: Attenuation Limit of Distribution Cable at 1550nm

4. End to End/Overall Section

- 1310nm A-EE13= [A-F13] + 7.5dB (Splitter 1x4) + [D-F13] + 11.0dB (Splitter 1x8) + [A-DR13]

A-EE13: Overall Attenuation of End to End at 1310nm

- 1550nm A-EE15= [A-F15] + 7.5dB (Splitter 1x4) + [D-F15] + 11.0dB (Splitter 1x8) + [A-DR15]

A-EE15: Overall Attenuation of End to End at 1550nm

Page 86: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 86 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Page 87: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 87 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

Form # Name From / To

Ia / IbTotal Loss Measurement 1310nm / 1550nmSubsystem: Oerall Segment (OTB-ODC-ODP)

From: OTB ①①①①To: ODP ⑤⑤⑤⑤

IIa / IIbSeg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nmSubsystem: Feeder Segment (OTB-ODC) without splitter

From: OTB ①①①①To: ODC ②②②②

IIc / IIdSeg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nmSubsystem: Feeder Segment (OTB-ODC) with passive splitter 1:4

From: OTB ①①①①To:ODC ④④④④

IIIa / IIIbSeg.B(ODC-ODP) Loss Measurement 1310nm/1550nmSubsystem: Segment B (ODC - ODP)

From: ODC ④④④④To: ODP ⑤⑤⑤⑤

2.1 APPLICATION OF MEASUREMENT FORMS

Form Ia / Ib(Overall Segment)

OTB

Feeder

Cable

ODCDistribution

Cable

1:8

splitter

ODP No.X

Port#.1

1:4 splitter

Port#.1

Sp

litt

er

#.1

Port#.1

Sp

litt

er

#.1

Port#.1

Form IIa / IIb (Feeder Segment / Seg.A)

Form IIIa / IIIb(Distribution Segment / Seg.B)

Form IIc / IId (Feeder Segment / Seg.A)

1 23

4

6

5

Page 88: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 88 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.1.1 FORM I a/I b: Overall Segment (OTB-ODC-ODP)

2 6

Distribution Cable Core No.

to be terminated at ODP

NOTE:

1) Input in accordance with

the site information, condition

2) Input when measurement3

5

1

OTB

Feeder

Cable

ODCDistribution

Cable 1:8

splitter

ODP No.X

Port#.1

1:4 splitter

Port#.1

Sp

litt

er#

.1 Port#.1

Sp

litt

er#

.1

Port#.1

OVERALL SEGMENT

1 23

4

6

5

Page 89: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 89 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.1.2 FORM II a/II b: Feeder Segment (OTB-ODC) without splitter

OTB

Feeder

Cable

ODCDistribution

Cable 1:8

splitter

ODP No.X

Port#.1

1:4 splitter

Port#.1

Sp

litt

er#

.1 Port#.1

Sp

litt

er#

.1

Port#.1

FEEDER SEGMENT

1 23

4

6

5

NOTE:

1) Input in accordance with the

site information, condition

2) Input when measurementInput Tray No.

1 2

Page 90: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 90 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.1.3 FORM II c/II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter

OTB

Feeder

Cable

ODCDistribution

Cable 1:8

splitter

ODP No.X

Port#.1

1:4 splitter

Port#.1

Sp

litt

er#

.1 Port#.1

Sp

litt

er#

.1

Port#.1

FEEDER SEGMENT with Splitter

1 23

4

6

5

1 3 4

NOTE:

1) Input in accordance with the

site information, condition

2) Input when measurement

Page 91: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 91 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.1.4 FORM III a/III b: Distribution Segment (ODC-ODP)

OTB

Feeder

Cable

ODCDistribution

Cable 1:8

splitter

ODP No.X

Port#.1

1:4 splitter

Port#.1

Sp

litt

er#

.1 Port#.1

Sp

litt

er#

.1

Port#.1

DISTRIBUTION SEGMENT

1 23

4

6

5

6 3 4

5

NOTE:

1) Input in accordance with the

site information, condition

2) Input when measurement

Page 92: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 92 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2 MEASUREMENT FORMS (File: UT-Form Measurement -r2.2.xls)

Note:

1) Forms provided hereunder is "r-2.3a", which is the

latest version as of 28 June, 2013.

2) It is to request users to confirm the latest version to JF

DJAFa Consortium before use Forms.

3) Use Forms of Excel format for submission purpose.

4) In case if the form is not enough (e.g. more than 5 ODP

(1:8 Splitter) are exist in one distribution cable), the

related "Worksheet of Excel" (e.g. Form I and III) shall

be duplicated/copied.

5) Do not incert any Line/Raw in the form so as not to

alter the calculation formula in the sheet.

Page 93: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 93 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.1 FORM I a: Overall Segment (OTB-ODC-ODP) @ 1310nm

FOR

M : I a

PT TELE

KO

MU

NIK

AS

I IND

ON

ES

IA

Sub S

istem : O

VER

ALL S

EG

ME

NT (O

TB - O

DC

- OD

P)

OD

C N

o.C

AP

AC

ITYE

00˚̊̊̊ 00'00"

CA

BLE

No.

WA

VE

LEN

GT

H

RE

SU

LT

No.

Po

rt No

.P

in (dB)

Po

ut (d

B)

Po

ut-P

in (d

B)

PA

SS

/FAIL

SE

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

Catatan: P

ower M

eter digunakan untuk test pelurusan kabel

*) Total Loss = (Cable length x 0,35 dB

+ Connector x 0.25dB

+ Splitter 1:4 x 7.25dB

+ Splitter 1:8 x 10.38dB

+ Splice x 0.1dB

)

CA

LC

UL

AT

ION

OF

LO

SS

BU

DG

ET

:

Unit

Attenuation

Splitter-.1

Splitter-.2

Splitter-.3

Splitter-.4

1. CA

BLE

LEN

GTH

(km)

0.35-

-

-

-

2. No. of S

PLIC

E (pcs)

0.1

3. No. of C

ON

NE

CTO

R (pcs)

0.25

4. SP

LITTER

1:4 (1 pc)7.25

5. SP

LITTER

1:8 (1 pc)10.38

0.000.00

0.000.00

FEE

DE

RD

ISTR

IBU

TIO

N

DIS

TRIB

UTIO

N

DIS

TRIB

UTIO

N

DIS

TRIB

UTIO

N

CA

BLE

LEN

GTH

(km):

Note: C

AB

LE LE

NG

TH of O

TDR

Indication

Overall Loss M

easurement 1310 nm

DA

TE

OF M

EA

SU

RE

ME

NT:

DA

ER

AS

TON

AM

A

LOK

AS

I

ATTE

NU

ATIO

N LIM

ITATIO

N (dB

)

- -

OD

C

PO

RT

No

.

LO

SS

BU

DG

ET-

-

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

OD

P C

OO

RD

INA

TE

S

00˚̊̊̊ 00'00"

Measurem

ent tools : Pow

er Meter

Specification/lim

itation : dB (C

able length x 0.35 dB + C

onnector x 0.25dB + S

plitter 1:4 x 7.25dB + S

plitter 1:8 x 10.38dB + S

plice x 0.1dB)

No of C

ores

1310nm

RE

MA

RK

S

FEE

DE

R C

AB

LED

IST

RIB

UT

ION

CA

BLE

00˚̊̊̊ 00'00"

OD

PA

TT

EN

UA

TIO

N (d

B)

No of C

ores

OTB

Port N

o.

CO

OR

DIN

ATE

SS

00˚̊̊̊ 00'00"

CA

BLE

No.

Page 94: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 94 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.2 FORM I b: Overall Segment (OTB-ODC-ODP) @ 1550nm

FO

RM

: I b

PT T

ELE

KO

MU

NIK

AS

I IND

ON

ES

IA

Sub

Sistem

: OVE

RA

LL S

EG

ME

NT (O

TB - O

DC

- OD

P)

OD

C N

o.

CA

PA

CIT

YE

00˚̊̊̊ 00'00"

CA

BLE

No.

WA

VE

LE

NG

TH

OD

P P

ort N

o.O

DP

S

pecificationlim

itation

Attenu

ation (d

B)

Resu

ltR

emarks

RE

SU

LT

No

.P

ort N

o.

Pin

(dB

)P

ou

t (dB

)P

ou

t-Pin

(dB

)P

AS

S/F

AIL

SE

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

Co

re No

.1

-

PA

SS

2-

P

AS

S

OD

P N

o.

3-

P

AS

S

4-

P

AS

S

5-

P

AS

S

Splitter N

o.6

-

PA

SS

7-

P

AS

S

8-

P

AS

S

*) Total Loss = (Cable length x 0,215 dB

+ Connector x 0.25dB

+ Splitter 1:4 x 7.25dB

+ Splitter 1:8 x 10.38dB

+ Splice x 0.1dB

)

CA

LCU

LA

TI

ON

OF

ATT

EN

UA

TI

ON

LIMIT:

Unit

Attenu

ationS

plitter-.1S

plitter-.2

Splitter-.3

Splitter-.4

0.2150

00

0

2. No. of S

PLIC

E (pcs)

0.1

3. No. of C

ON

NE

CTO

R (pcs)

0.25

4. SP

LITT

ER

1:4 (1 pc)7.25

5. SP

LITT

ER

1:8 (1 pc)10.38

0.000.00

0.000.00

FEE

DE

RD

ISTR

IBU

TIO

N

DIS

TRIB

UT

IO

N

DIS

TRIB

UTIO

N

DIS

TRIB

UTIO

N

CA

BL

E LE

NG

TH (km

):

Note: C

AB

LE L

EN

GTH

of OTD

R Ind

ication

Total Loss Measurem

ent 1550 nm

DA

TE

OF M

EA

SU

RE

ME

NT:

DA

ER

AS

TO

AT

TE

NU

AT

ION

(dB

)O

DP

CO

OR

DIN

AT

ES

FE

ED

ER

CA

BL

E

CO

OR

DIN

ATE

SS

00˚̊̊̊ 00'00"

CA

BLE

No

.

1. CA

BLE

LEN

GTH

(km)

ATT

EN

UA

TION

LIMITA

TION

(dB)

OD

C

PO

RT

No

.

LO

SS

BU

DG

ET

NA

MA

LOK

AS

I

No of C

ores

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

DIS

TR

IBU

TIO

N C

AB

LEN

o of C

ores

OTB

Port N

o.

Specificatio

n/limitatio

n : dB (C

able length

x 0.215 dB + C

onnecto

r x 0.25dB + S

plitter 1:4 x 7.25dB + S

plitter 1:8 x 10.38dB + S

plice x 0.1dB)

OD

P

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

1550nm

RE

MA

RK

S

Page 95: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 95 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.3 FORM II a: Feeder Segment (OTB-ODC) without splitter @ 1310nm

FO

RM

: II a

PT

TE

LE

KO

MU

NIK

AS

I IND

ON

ES

IA

WA

VE

LE

NG

TH

CA

PA

CIT

Y

OT

BR

ES

UL

T

PO

RT

No

.T

ray No

.P

ort N

o.

Pin

(dB

)P

ou

t (dB

)P

ou

t - Pin

(dB

)P

AS

S/F

AIL

11

-

PA

SS

22

-

PA

SS

33

-

PA

SS

44

-

PA

SS

55

-

PA

SS

66

-

PA

SS

77

-

PA

SS

88

-

PA

SS

99

-

PA

SS

1010

-

PA

SS

1111

-

PA

SS

1212

-

PA

SS

131

-

PA

SS

142

-

PA

SS

153

-

PA

SS

164

-

PA

SS

175

-

PA

SS

186

-

PA

SS

197

-

PA

SS

208

-

PA

SS

219

-

PA

SS

2210

-

PA

SS

2311

-

PA

SS

2412

-

PA

SS

251

-

PA

SS

262

-

PA

SS

273

-

PA

SS

284

-

PA

SS

295

-

PA

SS

306

-

PA

SS

317

-

PA

SS

328

-

PA

SS

339

-

PA

SS

3410

-

PA

SS

3511

-

PA

SS

3612

-

PA

SS

371

-

PA

SS

382

-

PA

SS

393

-

PA

SS

404

-

PA

SS

415

-

PA

SS

426

-

PA

SS

437

-

PA

SS

448

-

PA

SS

459

-

PA

SS

4610

-

PA

SS

4711

-

PA

SS

4812

-

PA

SS

Catatan

: Po

wer M

eter dig

un

akan u

ntu

k test pelu

rusan

kabel

*) Total Loss = (Cable length x 0,35 dB

+ Connector x 0.25dB

+ Splice x 0.1dB

)

CA

LC

UL

AT

ION

OF

AT

TE

NU

AT

ION

LIM

IT:Un

it Atten

uatio

nO

DC

1. CA

BL

E L

EN

GT

H (km

)0.35

-

2. No

. of S

PL

ICE

(pcs)

0.1

3. No

. of C

ON

NE

CT

OR

(pcs)

0.25

0.00

FE

ED

ER

CA

BL

E L

EN

GT

H (km

)

No

te: CA

BL

E L

EN

GT

H o

f OT

DR

Ind

ication

NA

MA

LO

KA

SI

Seg.A

(OTB

-OD

C_splitter) Lo

ss Measurem

ent 1310 nm

Su

b S

istem : F

EE

DE

R S

EG

ME

NT

(OT

B - O

DC

) WIT

HO

UT

SP

LIT

TE

RD

AT

E O

F M

EA

SU

RE

ME

NT

:

DA

ER

AS

TO

Measu

remen

t too

ls : Po

wer M

eter

OD

CN

AM

E/T

YP

E

1310nm

No

. of C

ores

OD

C C

OO

RD

INA

TE

SS

00˚̊̊̊00'00"E

00˚̊̊̊00'00"

Sp

ecification

/limitatio

n : d

B (C

able len

gth

x 0.35 dB

+ Co

nn

ector x 0.25d

B + S

plitter 1:4 x 7.25d

B + S

plice x 0.1d

B)

OD

CA

TT

NU

AT

ION

(dB

)

AT

TE

NU

AT

ION

LIM

ITA

TIO

N (d

B)

RE

MA

RK

S

FE

ED

ER

CA

BL

EC

AB

LE

No

.

No

.L

OS

S

BU

DG

ET

-

Page 96: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 96 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.4 FORM II b: Feeder Segment (OTB-ODC) without splitter @ 1550nm

FO

RM

: II b

PT

TE

LE

KO

MU

NIK

AS

I IND

ON

ES

IA

WA

VE

LE

NG

TH

CA

PA

CIT

Y

OT

BR

ES

UL

T

PO

RT

No

.T

ray No

.P

ort N

o.

Pin

(dB

)P

ou

t (dB

)P

ou

t - Pin

(dB

)P

AS

S/F

AIL

11

-

PA

SS

22

-

PA

SS

33

-

PA

SS

44

-

PA

SS

55

-

PA

SS

66

-

PA

SS

77

-

PA

SS

88

-

PA

SS

99

-

PA

SS

1010

-

PA

SS

1111

-

PA

SS

1212

-

PA

SS

131

-

PA

SS

142

-

PA

SS

153

-

PA

SS

164

-

PA

SS

175

-

PA

SS

186

-

PA

SS

197

-

PA

SS

208

-

PA

SS

219

-

PA

SS

2210

-

PA

SS

2311

-

PA

SS

2412

-

PA

SS

251

-

PA

SS

262

-

PA

SS

273

-

PA

SS

284

-

PA

SS

295

-

PA

SS

306

-

PA

SS

317

-

PA

SS

328

-

PA

SS

339

-

PA

SS

3410

-

PA

SS

3511

-

PA

SS

3612

-

PA

SS

371

-

PA

SS

382

-

PA

SS

393

-

PA

SS

404

-

PA

SS

415

-

PA

SS

426

-

PA

SS

437

-

PA

SS

448

-

PA

SS

459

-

PA

SS

4610

-

PA

SS

4711

-

PA

SS

4812

-

PA

SS

Catatan

: Po

wer M

eter dig

un

akan u

ntu

k test pelu

rusan

kabel

*) Total Loss = (Cable length x 0,215 dB

+ Connector x 0.25dB

+ Splice x 0.1dB

)

CA

LC

UL

AT

ION

OF

AT

TE

NU

AT

ION

LIM

IT:

Un

it Atten

uatio

nO

DC

1. CA

BL

E L

EN

GT

H (km

)0.215

-

2. No

. of S

PL

ICE

(pcs)

0.1

3. No

. of C

ON

NE

CT

OR

(pcs)

0.25

0.00

FE

ED

ER

CA

BL

E L

EN

GT

H (km

)

No

te: CA

BL

E L

EN

GT

H o

f OT

DR

Ind

ication

NA

MA

LO

KA

SI

Seg

.A(O

TB

-OD

C_sp

litter) Lo

ss Measu

remen

t 1550 nm

Su

b S

istem : F

EE

DE

R S

EG

ME

NT

(OT

B - O

DC

) WIT

HO

UT

SP

LIT

TE

RD

AT

E O

F M

EA

SU

RE

ME

NT

:

DA

ER

AS

TO

Measu

remen

t too

ls : Po

wer M

eter

OD

CN

AM

E/T

YP

E

1550nmN

o. o

f Co

res

OD

C C

OO

RD

INA

TE

SS

00˚̊̊̊00'00"E

00˚̊̊̊00'00"

Sp

ecification

/limitatio

n : d

B (C

able len

gth

x 0.215 dB

+ Co

nn

ector x 0.25d

B + S

plitter 1:4 x 7.25d

B + S

plice x 0.1d

B)

OD

CA

TT

NU

AT

ION

(dB

)

AT

TE

NU

AT

ION

LIM

ITA

TIO

N (d

B)

RE

MA

RK

S

FE

ED

ER

CA

BL

E

CA

BL

E N

o.

No

.L

OS

S

BU

DG

ET

-

Page 97: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 97 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.5 FORM II c: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1310nm

FO

RM

: II c

PT

TE

LE

KO

MU

NIK

AS

I IND

ON

ES

IA

WA

VE

LE

NG

TH

CA

PA

CIT

Y

OT

BR

ES

UL

T

PO

RT

No

.S

plitter

Po

rt No

.P

in (d

B)

Po

ut (d

B)

Po

ut - P

in (d

B)

PA

SS

/FA

IL

11

-

PA

SS

22

-

PA

SS

33

-

PA

SS

44

-

PA

SS

51

-

PA

SS

62

-

PA

SS

73

-

PA

SS

84

-

PA

SS

91

-

PA

SS

102

-

PA

SS

113

-

PA

SS

124

-

PA

SS

131

-

PA

SS

142

-

PA

SS

153

-

PA

SS

164

-

PA

SS

171

-

PA

SS

182

-

PA

SS

193

-

PA

SS

204

-

PA

SS

211

-

PA

SS

222

-

PA

SS

233

-

PA

SS

244

-

PA

SS

251

-

PA

SS

262

-

PA

SS

273

-

PA

SS

284

-

PA

SS

291

-

PA

SS

302

-

PA

SS

313

-

PA

SS

324

-

PA

SS

331

-

PA

SS

342

-

PA

SS

353

-

PA

SS

364

-

PA

SS

371

-

PA

SS

382

-

PA

SS

393

-

PA

SS

404

-

PA

SS

411

-

PA

SS

422

-

PA

SS

433

-

PA

SS

444

-

PA

SS

451

-

PA

SS

462

-

PA

SS

473

-

PA

SS

484

-

PA

SS

Catatan

: Po

wer M

eter dig

un

akan u

ntu

k test pelu

rusan

kabel

*) Total Loss = (Cable length x 0,35 dB

+ Connector x 0.25dB

+ Splitter 1:4 x 7.25dB

+ Splice x 0.1dB

)

CA

LC

UL

AT

ION

OF

AT

TE

NU

AT

ION

LIM

IT:Un

it Atten

uatio

nO

DC

1. CA

BL

E L

EN

GT

H (km

)0.35

-

2. No

. of S

PL

ICE

(pcs)

0.1

3. No

. of C

ON

NE

CT

OR

(pcs)

0.25

4. SP

LIT

TE

R 1:4 (1 p

c)7.25

0.00

FE

ED

ER

CA

BL

E L

EN

GT

H (km

)

No

te: CA

BL

E L

EN

GT

H o

f OT

DR

Ind

ication

Seg.A

(OTB

-OD

C_splitter) Loss M

easurement 1310 nm

Su

b Sistem

: FE

ED

ER

SE

GM

EN

T (O

TB - O

DC

) WIT

H P

AS

SIVE

SP

LITT

ER

1:4D

AT

E O

F M

EA

SU

RE

ME

NT

:

DA

ER

AS

TO

No

.O

DC

AT

TN

UA

TIO

N (d

B)

AT

TE

NU

AT

ION

LIM

ITA

TIO

N (d

B)

12345679101112

LO

SS

BU

DG

ET

-

1310nm

RE

MA

RK

S

8

Sp

ecification

/limitatio

n : d

B (C

able len

gth

x 0.35 dB

+ Co

nn

ector x 0.25d

B + S

plitter 1:4 x 7.25d

B + S

plice x 0.1d

B)

No

. of Co

res

OD

C C

OO

RD

INA

TE

SS

00˚̊̊̊00'00"E

00˚̊̊̊00'00"

Measu

remen

t too

ls : Po

wer M

eter

FE

ED

ER

CA

BL

EC

AB

LE

No

.O

DC

NA

MA

LO

KA

SI

NA

ME

/TYP

E

Page 98: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 98 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.6 FORM II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1550nm

FO

RM

: II d

PT

TE

LE

KO

MU

NIK

AS

I IND

ON

ES

IA

WA

VE

LE

NG

TH

CA

PA

CIT

Y

OT

BR

ES

UL

T

PO

RT

No

.S

plitter

Po

rt No

.P

in (d

B)

Po

ut (d

B)

Po

ut - P

in (d

B)

PA

SS

/FA

IL

11

-

PA

SS

22

-

PA

SS

33

-

PA

SS

44

-

PA

SS

51

-

PA

SS

62

-

PA

SS

73

-

PA

SS

84

-

PA

SS

91

-

PA

SS

102

-

PA

SS

113

-

PA

SS

124

-

PA

SS

131

-

PA

SS

142

-

PA

SS

153

-

PA

SS

164

-

PA

SS

171

-

PA

SS

182

-

PA

SS

193

-

PA

SS

204

-

PA

SS

211

-

PA

SS

222

-

PA

SS

233

-

PA

SS

244

-

PA

SS

251

-

PA

SS

262

-

PA

SS

273

-

PA

SS

284

-

PA

SS

291

-

PA

SS

302

-

PA

SS

313

-

PA

SS

324

-

PA

SS

331

-

PA

SS

342

-

PA

SS

353

-

PA

SS

364

-

PA

SS

371

-

PA

SS

382

-

PA

SS

393

-

PA

SS

404

-

PA

SS

411

-

PA

SS

422

-

PA

SS

433

-

PA

SS

444

-

PA

SS

451

-

PA

SS

462

-

PA

SS

473

-

PA

SS

484

-

PA

SS

Catatan

: Po

wer M

eter dig

un

akan u

ntu

k test pelu

rusan

kabel

*) Total Loss = (Cable length x 0,215 dB

+ Connector x 0.25dB

+ Splitter 1:4 x 7.25dB

+ Splice x 0.1dB

)

CA

LC

UL

AT

ION

OF

AT

TE

NU

AT

ION

LIM

IT:

Un

it Atten

uatio

nO

DC

1. CA

BL

E L

EN

GT

H (km

)0.215

-

2. No

. of S

PL

ICE

(pcs)

0.1

3. No

. of C

ON

NE

CT

OR

(pcs)

0.25

4. SP

LIT

TER

1:4 (1 pc)

7.25

0.00

FE

ED

ER

CA

BL

E L

EN

GT

H (km

)

No

te: CA

BL

E L

EN

GT

H o

f OT

DR

Ind

ication

Seg.A

(OTB

-OD

C_splitter) Loss M

easurement 1550 nm

Su

b S

istem : F

EE

DE

R S

EG

ME

NT

(OT

B - O

DC

) WIT

H P

AS

SIV

E S

PL

ITT

ER

DA

TE

OF

ME

AS

UR

EM

EN

T:

DA

ER

AS

TO

No

.O

DC

AT

TN

UA

TIO

N (d

B)

ATT

EN

UA

TIO

N L

IMIT

AT

ION

(dB

)

6 1234512 7891011

-

OD

C

NA

MA

LO

KA

SI

NA

ME

/TY

PE

Sp

ecification

/limitatio

n : d

B (C

able len

gth

x 0.215 dB

+ Co

nn

ector x 0.25d

B + S

plitter 1:4 x 7.25d

B + S

plice x 0.1d

B)

No

. of C

ores

OD

C C

OO

RD

INA

TE

SS

00˚̊̊̊00'00"E

00˚̊̊̊00'00"

Measu

remen

t too

ls : Po

wer M

eter

1550nm

RE

MA

RK

S

FE

ED

ER

CA

BL

E

CA

BL

E N

o.

LO

SS

BU

DG

ET

Page 99: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 99 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.7 FORM III a: Distribution Segment (ODC-ODP) @ 1310nm

FO

RM

: III a

PT

TE

LE

KO

MU

NIK

AS

I IND

ON

ES

IA

Su

b S

istem : S

EG

ME

NT

B (O

DC

- OD

P)

WA

VE

LE

NG

TH

1310nm

OD

PR

ES

UL

T

Po

rtP

in (d

B)

Po

ut (d

B)

Po

ut-P

in (d

B)

PA

SS

/FA

ILS

E

11

-

PA

SS

22

-

PA

SS

33

-

PA

SS

44

-

PA

SS

55

-

PA

SS

66

-

PA

SS

77

-

PA

SS

88

-

PA

SS

91

-

PA

SS

102

-

PA

SS

113

-

PA

SS

124

-

PA

SS

135

-

PA

SS

146

-

PA

SS

157

-

PA

SS

168

-

PA

SS

171

-

PA

SS

182

-

PA

SS

193

-

PA

SS

204

-

PA

SS

215

-

PA

SS

226

-

PA

SS

237

-

PA

SS

248

-

PA

SS

251

-

PA

SS

262

-

PA

SS

273

-

PA

SS

284

-

PA

SS

295

-

PA

SS

306

-

PA

SS

317

-

PA

SS

328

-

PA

SS

Catatan

: Po

wer M

eter dig

un

akan u

ntu

k test pelu

rusan

kabel

*) Total Loss = (Cable length x 0.35 dB

+ Connector x 0.25dB

+ Splitter 1:8 x 10.38dB

+ Splice x 0.1dB

)

CA

LC

UL

AT

ION

OF

AT

TE

NU

AT

ION

LIM

IT:

Un

it

Atten

uatio

nS

plitter-.1

Sp

litter-.2S

plitter-.3

Sp

litter-.4

1. CA

BL

E L

EN

GT

H (km

)0.35

-

-

-

-

2. No

. of S

PL

ICE

(pcs)

0.1

3. No

. of C

ON

NE

CT

OR

(pcs)

0.25

5. SP

LIT

TE

R 1:8 (1 p

c)10.38

0.000.00

0.000.00

DIS

TR

IBU

TIO

ND

IST

RIB

UT

ION

DIS

TR

IBU

TIO

ND

IST

RIB

UT

ION

CA

BL

E L

EN

GT

H (km

):

No

te: CA

BL

E L

EN

GT

H o

f OT

DR

Ind

ication

SP

LIT

TE

R

1:4

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

00˚̊̊̊ 00'00"

- - - -

NA

MA

LO

KA

SI

DIS

TR

IBU

TIO

N C

AB

LE

S P L IT T E R N o ._ _ _ __ _ _S P L IT T E R N o ._ __ _ _ __S P L IT T E R N o ._ _ _ __ _ _

O D C P o rt N o ._ __ _ _ __O D C P o rt N o ._ _ _ __ _ _O D C P o rt N o ._ __ _ _ __O D C P o rt N o .__ _ __ _ _

AT

TE

NU

AT

ION

LIM

ITA

TIO

N (d

B)

No

.O

DP

O D P N o .__ _ _ __ _ _ _O D P N o ._ _ __ _ _ __ _O D P N o ._ __ _ __ _ _ _O D P N o ._ _ _ __ _ _ __

S P L IT T E R N o ._ __ _ __ _

CA

PA

CIT

YN

o o

f Co

res

Measu

remen

t too

ls : Po

wer M

eter

Sp

ecification

/limitatio

n : d

B (C

able len

gth

x 0.35 dB

+ Co

nn

ector x 0.25d

B + S

plitter 1:8 x 10.38d

B + S

plice x 0.1d

B)

AT

TE

NU

AT

ION

(dB

)O

DP

CO

OR

DIN

AT

ES

LO

SS

BU

DG

ET

RE

MA

RK

S

OD

C

OD

C C

OO

RD

INA

TE

SS

00˚̊̊̊ 00'00"E

00˚̊̊̊ 00'00"

No

.C

AB

LE

No

.

Seg

.B (O

DC

-OD

P) Loss M

easuremen

t 1310 nm

DA

TE

OF

ME

AS

UR

EM

EN

T:

DA

ER

AS

TO

Page 100: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 100 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.8 FORM III b: Distribution Segment (ODC-ODP) @ 1550nm

FO

RM

: III b

PT

TE

LE

KO

MU

NIK

AS

I IND

ON

ES

IA

Su

b S

istem : S

EG

ME

NT

B (O

DC

- OD

P)

WA

VE

LE

NG

TH

1550nm

OD

PR

ES

UL

T

Po

rtP

in (d

B)

Po

ut (d

B)

Po

ut-P

in (d

B)

PA

SS

/FA

ILS

E

11

-

PA

SS

22

-

PA

SS

33

-

PA

SS

44

-

PA

SS

55

-

PA

SS

66

-

PA

SS

77

-

PA

SS

88

-

PA

SS

91

-

PA

SS

102

-

PA

SS

113

-

PA

SS

124

-

PA

SS

135

-

PA

SS

146

-

PA

SS

157

-

PA

SS

168

-

PA

SS

171

-

PA

SS

182

-

PA

SS

193

-

PA

SS

204

-

PA

SS

215

-

PA

SS

226

-

PA

SS

237

-

PA

SS

248

-

PA

SS

251

-

PA

SS

262

-

PA

SS

273

-

PA

SS

284

-

PA

SS

295

-

PA

SS

306

-

PA

SS

317

-

PA

SS

328

-

PA

SS

Catatan

: Po

wer M

eter dig

un

akan u

ntu

k test pelu

rusan

kabel

*) Total Loss = (Cable length x 0.215 dB

+ Connector x 0.25dB

+ Splitter 1:8 x 10.38dB

+ Splice x 0.1dB

)

CA

LC

UL

AT

ION

OF

AT

TE

NU

AT

ION

LIM

IT:

Un

it

Atten

uatio

nS

plitter-.1

Sp

litter-.2S

plitter-.3

Sp

litter-.4

1. CA

BL

E L

EN

GT

H (km

)0.215

2. No

. of S

PL

ICE

(pcs)

0.1

3. No

. of C

ON

NE

CT

OR

(pcs)

0.25

5. SP

LIT

TE

R 1:8 (1 p

c)10.38

0.000.00

0.000.00

DIS

TR

IBU

TIO

ND

IST

RIB

UT

ION

DIS

TR

IBU

TIO

ND

IST

RIB

UT

ION

CA

BL

E L

EN

GT

H (km

):

No

te: CA

BL

E L

EN

GT

H o

f OT

DR

Ind

ication

Seg.B

(OD

C-O

DP

) Loss Measurem

ent 1550 nm

DA

TE

OF

ME

AS

UR

EM

EN

T:

DA

ER

AS

TO

OD

C C

OO

RD

INA

TE

SS

00˚̊̊̊ 00'00"E

00˚̊̊̊ 00'00"

No

.C

AB

LE

No

.

AT

TE

NU

AT

ION

LIM

ITA

TIO

N (d

B)

No

.O

DP

O D P N o ._ _ _ _ _ _ _ _ _O D P N o ._ _ _ _ _ _ _ _ _O D P N o ._ _ _ _ _ _ _ _ _O D P N o ._ _ _ _ _ _ _ _ _

S P L IT T E R N o ._ _ _ _ _ _ _

AT

TE

NU

AT

ION

(dB

)L

OS

S

BU

DG

ET-

NA

MA

LO

KA

SI

S P L IT T E R N o ._ _ _ _ _ _ _S P L IT T E R N o ._ _ _ _ _ _ _S P L IT T E R N o ._ _ _ _ _ _ _

O D C P o rt N o ._ _ _ _ _ _ _O D C P o rt N o ._ _ _ _ _ _ _O D C P o rt N o ._ _ _ _ _ _ _O D C P o rt N o ._ _ _ _ _ _ _

CA

PA

CIT

YN

o o

f Co

res

Measu

remen

t too

ls : Po

wer M

eter

Sp

ecification

/limitatio

n : d

B (C

able len

gth

x 0.215 dB

+ Co

nn

ector x 0.25d

B + S

plitter 1:8 x 10.38d

B + S

plice x 0.1d

B)

OD

P C

OO

RD

INA

TE

SR

EM

AR

KS

SP

LIT

TE

R

1:4

DIS

TR

IBU

TIO

N C

AB

LE

- - -

OD

C

Page 101: Handbook for ftth osp v1.0

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

Page 101 HANDBOOK for FTTH-OSP v 1.0 (June 2013)Copyright©Fujikura Ltd./Y.N

2.2.9 FORM IV: Splice Loss Record

FO

RM

: IV

PT

TE

LE

KO

MU

NIK

AS

I IND

ON

ES

IA

Su

b S

istem : F

eeder C

able

Fiber No.Loss (dB)PASS/FAILFiber No.Loss (dB)PASS/FAIL

Fiber No.Loss (dB)PASS/FAILFiber No.Loss (dB)PASS/FAIL

Fiber No.Loss (dB)PASS/FAILFiber No.Loss (dB)PASS/FAIL

1P

AS

S49

PA

SS

97P

AS

S145

PA

SS

193P

AS

S241

PA

SS

2P

AS

S50

PA

SS

98P

AS

S146

PA

SS

194P

AS

S242

PA

SS

3P

AS

S51

PA

SS

99P

AS

S147

PA

SS

195P

AS

S243

PA

SS

4P

AS

S52

PA

SS

100P

AS

S148

PA

SS

196P

AS

S244

PA

SS

5P

AS

S53

PA

SS

101P

AS

S149

PA

SS

197P

AS

S245

PA

SS

6P

AS

S54

PA

SS

102P

AS

S150

PA

SS

198P

AS

S246

PA

SS

7P

AS

S55

PA

SS

103P

AS

S151

PA

SS

199P

AS

S247

PA

SS

8P

AS

S56

PA

SS

104P

AS

S152

PA

SS

200P

AS

S248

PA

SS

9P

AS

S57

PA

SS

105P

AS

S153

PA

SS

201P

AS

S249

PA

SS

10P

AS

S58

PA

SS

106P

AS

S154

PA

SS

202P

AS

S250

PA

SS

11P

AS

S59

PA

SS

107P

AS

S155

PA

SS

203P

AS

S251

PA

SS

12P

AS

S60

PA

SS

108P

AS

S156

PA

SS

204P

AS

S252

PA

SS

13P

AS

S61

PA

SS

109P

AS

S157

PA

SS

205P

AS

S253

PA

SS

14P

AS

S62

PA

SS

110P

AS

S158

PA

SS

206P

AS

S254

PA

SS

15P

AS

S63

PA

SS

111P

AS

S159

PA

SS

207P

AS

S255

PA

SS

16P

AS

S64

PA

SS

112P

AS

S160

PA

SS

208P

AS

S256

PA

SS

17P

AS

S65

PA

SS

113P

AS

S161

PA

SS

209P

AS

S257

PA

SS

18P

AS

S66

PA

SS

114P

AS

S162

PA

SS

210P

AS

S258

PA

SS

19P

AS

S67

PA

SS

115P

AS

S163

PA

SS

211P

AS

S259

PA

SS

20P

AS

S68

PA

SS

116P

AS

S164

PA

SS

212P

AS

S260

PA

SS

21P

AS

S69

PA

SS

117P

AS

S165

PA

SS

213P

AS

S261

PA

SS

22P

AS

S70

PA

SS

118P

AS

S166

PA

SS

214P

AS

S262

PA

SS

23P

AS

S71

PA

SS

119P

AS

S167

PA

SS

215P

AS

S263

PA

SS

24P

AS

S72

PA

SS

120P

AS

S168

PA

SS

216P

AS

S264

PA

SS

25P

AS

S73

PA

SS

121P

AS

S169

PA

SS

217P

AS

S265

PA

SS

26P

AS

S74

PA

SS

122P

AS

S170

PA

SS

218P

AS

S266

PA

SS

27P

AS

S75

PA

SS

123P

AS

S171

PA

SS

219P

AS

S267

PA

SS

28P

AS

S76

PA

SS

124P

AS

S172

PA

SS

220P

AS

S268

PA

SS

29P

AS

S77

PA

SS

125P

AS

S173

PA

SS

221P

AS

S269

PA

SS

30P

AS

S78

PA

SS

126P

AS

S174

PA

SS

222P

AS

S270

PA

SS

31P

AS

S79

PA

SS

127P

AS

S175

PA

SS

223P

AS

S271

PA

SS

32P

AS

S80

PA

SS

128P

AS

S176

PA

SS

224P

AS

S272

PA

SS

33P

AS

S81

PA

SS

129P

AS

S177

PA

SS

225P

AS

S273

PA

SS

34P

AS

S82

PA

SS

130P

AS

S178

PA

SS

226P

AS

S274

PA

SS

35P

AS

S83

PA

SS

131P

AS

S179

PA

SS

227P

AS

S275

PA

SS

36P

AS

S84

PA

SS

132P

AS

S180

PA

SS

228P

AS

S276

PA

SS

37P

AS

S85

PA

SS

133P

AS

S181

PA

SS

229P

AS

S277

PA

SS

38P

AS

S86

PA

SS

134P

AS

S182

PA

SS

230P

AS

S278

PA

SS

39P

AS

S87

PA

SS

135P

AS

S183

PA

SS

231P

AS

S279

PA

SS

40P

AS

S88

PA

SS

136P

AS

S184

PA

SS

232P

AS

S280

PA

SS

41P

AS

S89

PA

SS

137P

AS

S185

PA

SS

233P

AS

S281

PA

SS

42P

AS

S90

PA

SS

138P

AS

S186

PA

SS

234P

AS

S282

PA

SS

43P

AS

S91

PA

SS

139P

AS

S187

PA

SS

235P

AS

S283

PA

SS

44P

AS

S92

PA

SS

140P

AS

S188

PA

SS

236P

AS

S284

PA

SS

45P

AS

S93

PA

SS

141P

AS

S189

PA

SS

237P

AS

S285

PA

SS

46P

AS

S94

PA

SS

142P

AS

S190

PA

SS

238P

AS

S286

PA

SS

47P

AS

S95

PA

SS

143P

AS

S191

PA

SS

239P

AS

S287

PA

SS

48P

AS

S96

PA

SS

144P

AS

S192

PA

SS

240P

AS

S288

PA

SS

Catatan

: Sp

lice Lo

ss of E

stimated

Lo

ss ind

icated b

y Fu

sion

Sp

licer

Sp

ecification

/limitatio

n : 0.1 d

B

Seg

.A(O

TB

-OD

C_sp

litter) Sp

lice Lo

ss Measu

remen

t by S

plicer

DA

TE

OF

ME

AS

UR

EM

EN

T

DA

ER

AS

TO

FE

ED

ER

CA

BL

E A

FE

ED

ER

CA

BL

E B

Measu

remen

t too

ls : Fu

sion

splicer