hardware universe-controllers.pdf
TRANSCRIPT
NetApp Hardware Universe – Storage Controllers – RC-0032-0212 – Side A – 02-15-2012
Fabric-Attached Storage (FAS), V-Series, and Storage Acceleration (SA) Controllers
ModelFAS/V6280
SA620FAS/V6240 FAS/V6210
FAS/V6080
SA600FAS/V6040
FAS/V3270
SA3201FAS/V32401 FAS/V3210 FAS/V3170 FAS/V3160 FAS/V314
Front View
Max Capacity2
(7.3.x / 8.0.x / 8.1.x)
- / 4320TB3 /
4320TB3 - / 4320TB3 /
4320TB3 - / 3600TB3 /
3600TB31176TB / 3528TB3
/ 3528TB3840TB / 2520TB3
/ 2520TB3 960TB / 2880TB3
/ 2880TB3 600TB / 1800TB3
/ 1800TB3 240TB / 720TB3
/ 720TB3840TB / 2520TB3
/ 2520TB3672TB / 2016TB3
/ 2016TB3420TB / 1260TB
/ 1260TB
Max Aggregate4
(7.3.x / 8.0.x / 8.1.x) - / 100TB / 162TB - / 100TB / 162TB - / 70TB / 162TB
16TB / 100TB /
162TB
16TB / 70TB /
105TB
16TB / 70TB /
105TB
16TB / 50TB /
90TB16TB / 50TB / 75TB
16TB / 70TB /
105TB16TB / 50TB / 90TB 16TB / 50TB / 75TB
Max FlexVol Size
(7.3.x / 8.0.x / 8.1.x)- / 100TB / 100TB - / 100TB / 100TB - / 70TB / 70TB
16TB / 100TB /
100TB16TB / 70TB / 70TB 16TB / 70TB / 70TB 16TB / 50TB / 50TB 16TB / 50TB / 50TB 16TB / 70TB / 70TB 16TB / 50TB / 50TB 16TB / 50TB / 50TB
Max Shelves(DS2446 / DS4243 / DS14)
60 / 60 / 84 60 / 60 / 84 50 / 50 / 72 49 / 49 / 84 35 / 35 / 60 40 / 40 / 40 25 / 25 / 42 10 / 10 / 17 35 / 35 / 60 28 / 28 / 48 17.5 / 17.5 / 30
Max Drive
Quantity1440 1440 1200 1176 840 960 600 240 840 672 420
Ethernet
(HA / Single)
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
4 / 2 GbE RJ45
8 / 4 10GbE SFP+
12 / 6
GbE RJ45
12 / 6
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
4 / 2
GbE RJ45
FC Ports
(HA / Single)
8-32 / 4-16
8Gb SFP+78-32 / 4-16
8Gb SFP+78-16 / 4-8
8Gb SFP+716 / 8
4Gb SFP
16 / 8
4Gb SFP
4 / 2
4Gb SFP
4 / 2
4Gb SFP
4 / 2
4Gb SFP
8 / 4
4Gb SFP
8 / 4
4Gb SFP
8 / 4
4Gb SFP
SAS Ports
(HA / Single)
0-24 / 0-12
6Gb QSFP80-24 / 0-12
6Gb QSFP80-8 / 0-4
6Gb QSFP8- -
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP
4 / 2
6Gb QSFP- - -
Please recycle after use. Feedback and questions can be sent to [email protected]
Depth: 29 in. (73.66 cm)
Please recycle after use. Feedback and questions can be sent to [email protected]
FAS/V6200 and SA620
(Single controller show)
3
4
5
6
LINK LINKLINK LINK
0a 0b 0c 0d
INT LNK
LNK ACT
LNK ACT
10
9
8
7 13
14
15
16
NVRAM8 adapter is placed in slot 2 in a FAS6200 series controller (as shown). FAS6210 model does not support IOXM.
Q
Q
Slot 3
Slot 6
Slot 5
Slot 4
Slot 13
Slot 16
Slot 14
Slot 15
Slot 7
Slot 10
Slot 9
Slot 8
Slot 1
Slot 11
Slot 12
+++++P +++
17.53 in. (44.52 cm)
10.2 in.
(25.86 cm)
A
B
1
2
DC AC
x2
2
KNLKNL
0a0b
e0a
e0b
e0c
e0d
KNL
0bP
FAS2240-2
17.6 in. (44.7 cm)
NetApp Hardware Universe – Storage Controllers – RC-0032-0212 – Side B – 02-15-2012
KNLKNL
0a0b
e0a
e0b
e0c
e0d
KNLKNL
0a0b
e0a
e0b
e0c
e0d
Depth: 24 in. (61 cm)
FAS2240-4
17.7 in. (44.9 cm)
7 in.
(17.8 cm)
P
P
Expansion
PCIe
Gigabit Ethernet
RJ45
4Gb Fibre Channel
SFP
Serial-Attached SCSI
QSFP
Serial Console
RJ45
HA Interconnect
IB4X
Expansion
PCI-X
10 Gigabit Ethernet
SFP++
8Gb Fibre Channel
SFP++
Alternate Control Path
RJ45P
Remote Management
RJ45
HA Interconnect
QSFPQ
HA Interconnect
SFP++
0a 0b
LNK LNK
0c
0d e0b
e0a
c0b
c0a
3
4
FAS/V3200 & SA320
(Single contoller shown)
P
Slot 3
Slot 4
+
+
17.61 in. (44.7 cm)
FAS2040
P
P
17.6 in. (44.7 cm)
Depth: 29 in. (73.66 cm)
8 975 642 31
8 975 642 31
e0e e0f
d0ec0eb0ea0eRLM
0f h0g0e00b d0c0a0
2HI-POT2200VDC1
HI-POT2200VDC
REPLACE THIS ITEM
WITHIN 2 MINUTES OF
REMOVAL
REPLACE THIS ITEM
WITHIN 2 MINUTES OF
REMOVAL
PROPERLY SHUT DOWN SYSTEM BEFORE OPENING CHASSIS.
FAS/V6000 and SA600
(Single controller shown)
Slot 2
Slot 9
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
17.53 in. (44.52 cm)
10.32 in.
(26.21 cm)
FAS/V3100
17.73 in. (45 cm)
Please recycle after use. Feedback and questions can be sent to [email protected]
© 2012 NetApp, Inc.
change without notice. NetApp, the NetApp logo, Go
further, faster, Data ONTAP, NOW, SnapMirror and
MetroCluster are trademarks or registered trademarks
of NetApp, Inc. in the United States and/or other coun-
tries. All other brands or products are trademarks or
registered trademarks of their respective holders and
should be treated as such.
RC-0032-0212
This document is subject to change without notice.
ration Guide at
current information. NetApp employees and partners
can check the NetApp 1Stop site at
netapp1stop.com
should check with their account teams for updates.
This po
Enablement and Solutions Organization (TESO).
ACP – Alternate Control Path
BTU – British Thermal Unit
Cu – Copper Connector
FAS – Fabric-Attached Storage
FCP – Fibre Channel Protocol
FC – Fibre Channel
GbE – Gibabit Ethernet
HA – High Availability
HT – Hyper-Threading
IB4X
LUN – Logical Unit Number
NIC – Network Interface Card
NVRAM – Nonvolatile RAM
Op – Optical Connector
1
2 System capacity is calculated using base 10 arithmetic (1TB=1,000,000,000,000 bytes) and is derived based on the type, size, and
number of drives.
3 Max capacity shown can only be achieved using 3TB drives under Data ONTAP 8.0.2 or greater.
4 Maximum aggregate size is calculated using base 2 arithmetic (1TB = 240 bytes).
5 AC Power values shown are based on typical system values with 2 power supply units. Please refer to the Site Requirements Guide on
the NOW site for worst-case values.
6 Thermal disspation values shown are based on typcial system values. Please refere to the Site Requirements Guide on the NOW site for
worst-case thermal dissapation values.
7 FAS6200 embedded Fibre Channel ports and Fibre Channel ports on the vertical FC boards, all are considered as on-board ports, can be
set as target or initiators and support operation at 2, 4, or 8Gb speeds. Operation at 1Gb speeds is not supported.
8
9 100 LUNs from one array using one array LUN group. Combined LUN and NetApp disk can total 240 devices.
10 NVMEM on FAS2240 leverages portion of the 6GB of controller memory, resulting in ~5.25GB memory for Data ONTAP.
11 NVMEM allocation on the FAS2040 is 512MB with Data ONTAP 8.0 and higher and 256MB with Data ONTAP 7.3.x releases.
NetApp Hardware Universe – Storage Controllers – RC-0032-0212 – Side C – 02-15-2012
Expansion
PCIe
Gigabit Ethernet
RJ45
4Gb Fibre Channel
SFP
Serial-Attached SCSI
QSFP
Serial Console
RJ45
HA Interconnect
IB4X
Expansion
PCI-X
10 Gigabit Ethernet
SFP++
8Gb Fibre Channel
SFP++
Alternate Control Path
RJ45P
Remote Management
RJ45
HA Interconnect
QSFPQ
HA Interconnect
SFP++