HARMONICS
BY IFTEKHAR
E1 - 11213
M.H.S.S.P
![Page 2: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/2.jpg)
WHAT IS HARMONICS?
“A COMPONENT FREQUENCY OF A HARMONIC MOTION OF AN ELECTRO MAGNETIC WAVE I.E AN INTEGRAL MULTIPLE OF FUNDAMENTAL FREQUENCY”.
US FUNDAMENTAL FREQUENCY ARE 50Hz.
![Page 3: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/3.jpg)
WHAT CAUSES OF HARMONICS ?
NON-LINEAR LOAD
(CURRENT IS NOT PROPOTIONAL TO VOLTAGE)
![Page 4: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/4.jpg)
NON-LINEAR LOAD
GRAH SHOWS THE RELATION BETWEEN VOLTAGE & CURRENT
NON-LINEAR LOADS ARE SWITCHED ON ONLY PART OF THE CYCLE.
EG:DIODE , TRANSISTOR , ETC.
![Page 6: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/6.jpg)
SOURCE OF HARMONICS Converters, Devices which includes semi-conductor elements, Generators, Motors, Computers, Electronic ballasts, Switching power supplies, Welding machines, Control circuits, HVDC transmission systems, Electrical Communication systems. Transformers
![Page 7: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/7.jpg)
WHAT DO HARMONIC DO ?
HARMONIC ARE CARRIED THROUGH THE SYSTEM FROM THE SOURCE CAN BE NEARLY DOUBLE THE AMOUNT OF CURRENTON THE NEUTRAL CONDUCTOR IN 3 PHASE 4 WIRE DISTRIBUTION SYSTEM.
OVERALL ELECTRICAL SYSTEM & POWER QUALITYIS AFFECTED BY THE HARMONICS.
![Page 8: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/8.jpg)
EFECT OF HARMONIC ON SUPLY DISORTED VOLTAGE.
OVERHEATED OF TRENSFORMER & MOTOR
HEATING OF NEUTRAL CONDUCTOR.
![Page 9: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/9.jpg)
EFFECT ON TRANSFORMER Transformer overheating and potential
insulation failure result from several
conditions caused by harmonics:
Increased skin and proximity effects
Harmonics circulating in the primary winding
Increased hysteresis losses
Increased eddy current losses
![Page 10: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/10.jpg)
10
Solutions
Power filters .
Isolation transformer .
Line reactors.
Online UPS. HARMONIC CONVERTOR
19-10-2005
![Page 11: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/11.jpg)
HOW CAN ELIMINATE 6-pulse converter
12-pulse converter
18-pulse converter
note the level of distortionand steep current rise.
the waveform appears moresinusoidal, but still not very smooth.
virtually indistinguishablefrom the source currentwaveform.
![Page 12: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/12.jpg)
CONCLUSION The harmonic distortion principally
comes from Nonlinear-Type Loads. The application of power
electronics is causing increased level of harmonics due to Switching!!
Harmonic distortion can cause serious Failure/Damage problems
![Page 13: Harmonics 130307055153-phpapp02](https://reader036.vdocument.in/reader036/viewer/2022091118/5564131fd8b42a080c8b534a/html5/thumbnails/13.jpg)
QUESTIONS ?