hat creek burgercompany

5
MECHANICAL COMPLIANCE REVISION DATE DATE: SCALE: DRAWN BY: SHEET TITLE: SHEET NUMBER: REVISIONS PROJECT: 07-02-21 STAFF M0.0 HAT CREEK BURGER COMPANY ATHENS, GEORGIA AS NOTED 14901 Quorum Dr. #565 Dallas, TX 75254 rtmassociates.com | 972.387.3500 State of Georgia COA: PEF006838 1 MECHANICAL COMCHECK SCALE: NONE

Upload: others

Post on 13-Jan-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HAT CREEK BURGERCOMPANY

MECHANICAL

COMPLIANCE

REVISIONDATE

DATE:

SCALE:

DRAWN BY:

SHEET TITLE:

SHEET NUMBER:

REVISIONS

PRO

JEC

T:

07-02-21

STAFF

M0.0

HA

T C

REE

K B

UR

GER

CO

MPA

NY

ATH

ENS,

GEO

RG

IA

AS NOTED

14

901

Q

uo

ru

m D

r. #

565

D

alla

s, T

X 7

52

54

rtm

asso

cia

te

s.com

| 9

72

.3

87

.3

50

0

Sta

te

o

f G

eo

rgia

C

OA

: P

EF

00

68

38

1

MECHANICAL COMCHECK

SCALE: NONE

AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
21.WMA.037
Page 2: HAT CREEK BURGERCOMPANY

B

B

K.2

K.2

1

6

E.2

E.2

G

G

H

H

K.1

K.1

D

D

5

1.1

A.1

A.1

B.2

B.2

B.1

B.1

A

A

5.1

E

E

J

J

3

2.1

4

L

L

K

K

C

C

F

F

2

1

6

5

1.1

5.1

3

2.1

4

2

1

MEP ROOF PLAN

1/4"=1'-0"

MEP

ROOF

PLAN

REVISIONDATE

DATE:

SCALE:

DRAWN BY:

SHEET TITLE:

SHEET NUMBER:

REVISIONS

PRO

JEC

T:

07-02-21

STAFF

MEP1.0

HA

T C

REE

K B

UR

GER

CO

MPA

NY

ATH

ENS,

GEO

RG

IA

AS NOTED

14

90

1 Q

uo

ru

m D

r. #5

65

D

alla

s, T

X 75

25

4

rtm

asso

cia

tes.co

m | 9

72.3

87

.3

50

0

Sta

te

of G

eo

rg

ia

C

OA

: P

EF

00

68

38

GENERAL NOTES

KEYED NOTES

08.09.2021 & Clarifications

Owner Changes

AutoCAD SHX Text
J
AutoCAD SHX Text
4
AutoCAD SHX Text
POS-26
AutoCAD SHX Text
WP
AutoCAD SHX Text
10
AutoCAD SHX Text
23E
AutoCAD SHX Text
23D
AutoCAD SHX Text
11
AutoCAD SHX Text
30A/3P/20AF/NEMA3R DISC. SWITCH
AutoCAD SHX Text
M
AutoCAD SHX Text
WP
AutoCAD SHX Text
19
AutoCAD SHX Text
10
AutoCAD SHX Text
14C
AutoCAD SHX Text
11
AutoCAD SHX Text
WP
AutoCAD SHX Text
A-62/64/66
AutoCAD SHX Text
A-73
AutoCAD SHX Text
15
AutoCAD SHX Text
2
AutoCAD SHX Text
60A/50AF/3P/3R DISC. SWITCH
AutoCAD SHX Text
3
AutoCAD SHX Text
HB-1
AutoCAD SHX Text
4" VTR
AutoCAD SHX Text
9
AutoCAD SHX Text
1" GAS (500 MBH) (2.0 PSI)
AutoCAD SHX Text
1" GAS (860 MBH) (2.0 PSI)
AutoCAD SHX Text
3/4" GAS (357 MBH) (2.0 PSI)
AutoCAD SHX Text
1 1/4" GAS (1217 MBH) (2.0 PSI)
AutoCAD SHX Text
3/4" GAS (336 MBH) (2.0 PSI)
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
CO
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
%%UKEF-2
AutoCAD SHX Text
%%UKEF-1
AutoCAD SHX Text
%%UTEF-1
AutoCAD SHX Text
%%UKEF-3
AutoCAD SHX Text
%%URTU-2
AutoCAD SHX Text
%%URTU-1
AutoCAD SHX Text
%%UMAU-1
AutoCAD SHX Text
10'-0" MIN CLEARANCE
AutoCAD SHX Text
10'-0" MIN CLEARANCE
AutoCAD SHX Text
10'-0" MIN CLEARANCE
AutoCAD SHX Text
14
AutoCAD SHX Text
16
AutoCAD SHX Text
14
AutoCAD SHX Text
16
AutoCAD SHX Text
14
AutoCAD SHX Text
16
AutoCAD SHX Text
60A/3P/60AF/NEMA3R DISC. SWITCH
AutoCAD SHX Text
A-68/70/72
AutoCAD SHX Text
A-73
AutoCAD SHX Text
15
AutoCAD SHX Text
2
AutoCAD SHX Text
14
AutoCAD SHX Text
FACTORY DISC. SWITCH
AutoCAD SHX Text
A-31/33 THRU 30A/3P/20AF/NEMA 3R DISC. SWITCH
AutoCAD SHX Text
5
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
6
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
7
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
8
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
12
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
20
AutoCAD SHX Text
24X24
AutoCAD SHX Text
24X24
AutoCAD SHX Text
1 1/4" GAS (1779 MBH) (2.0 PSI)
AutoCAD SHX Text
1-1/2" GAS (2177 MBH) (2.0 PSI)
AutoCAD SHX Text
3/4" GAS (562 MBH) (2.0 PSI)
AutoCAD SHX Text
13
AutoCAD SHX Text
CO
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
WP
AutoCAD SHX Text
A-65
AutoCAD SHX Text
21
AutoCAD SHX Text
WP
AutoCAD SHX Text
A-65
AutoCAD SHX Text
21
AutoCAD SHX Text
A-65
AutoCAD SHX Text
21
AutoCAD SHX Text
A-65
AutoCAD SHX Text
21
AutoCAD SHX Text
11
AutoCAD SHX Text
1
AutoCAD SHX Text
AIRFLOW.
AutoCAD SHX Text
COOLING COIL MODULE.
AutoCAD SHX Text
AIRFLOW.
AutoCAD SHX Text
3/4" GAS (226 MBH) (2.0 PSI)
AutoCAD SHX Text
3/4" GAS (398 MBH) (2.0 PSI)
AutoCAD SHX Text
S
AutoCAD SHX Text
WP
AutoCAD SHX Text
J
AutoCAD SHX Text
4
AutoCAD SHX Text
POS-24
AutoCAD SHX Text
WP
AutoCAD SHX Text
S
AutoCAD SHX Text
WP
AutoCAD SHX Text
A-65
AutoCAD SHX Text
21
AutoCAD SHX Text
A-74/76/78
AutoCAD SHX Text
A-80/82/84
AutoCAD SHX Text
A-28/30/32
AutoCAD SHX Text
A-50/52/54
AutoCAD SHX Text
CD
AutoCAD SHX Text
CO
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
4" VTR
AutoCAD SHX Text
1 1/4"
AutoCAD SHX Text
30A/3P/30AF/NEMA 3R DISC. SWITCH INTERLOCK WITH MUA-1
AutoCAD SHX Text
A-23/25/27
AutoCAD SHX Text
A-17/19/21
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
22
AutoCAD SHX Text
22
AutoCAD SHX Text
22
AutoCAD SHX Text
22
AutoCAD SHX Text
POS-32
AutoCAD SHX Text
POS-32
AutoCAD SHX Text
ROOF MOUNTED UPLIGHT FIXTURE (TYPICAL) VERIFY EXACT LOCATION PRIOR TO ROUGH IN
AutoCAD SHX Text
J
AutoCAD SHX Text
4
AutoCAD SHX Text
POS-26
AutoCAD SHX Text
WP
AutoCAD SHX Text
S
AutoCAD SHX Text
WP
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
21.WMA.037
AutoCAD SHX Text
A.
AutoCAD SHX Text
ALL OUTDOOR AIR INTAKES BY MECHANICAL EQUIPMENT SHALL HAVE A MINIMUM 10'-0" HORIZONTAL CLEARANCE FROM THE DISCHARGE OF ANY EXHAUST FAN, COMBUSTION EXHAUST OR PLUMBING VENT.
AutoCAD SHX Text
B.
AutoCAD SHX Text
PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE DUCT/ PIPING CONNECTIONS TO ALL MOVING MACHINERY NOT INTERNALLY ISOLATED.
AutoCAD SHX Text
C.
AutoCAD SHX Text
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL ELECTRICAL WORK SHOWN ON THE MECHANICAL DRAWINGS.
AutoCAD SHX Text
D.
AutoCAD SHX Text
REFER TO STRUCTURAL ROOF FRAMING PLAN FOR EXACT ROOF CURB LOCATIONS.
AutoCAD SHX Text
1.
AutoCAD SHX Text
INTERWIRE SERVICE FROM FREEZER COMPRESSOR AND TIMECLOCK TO BLOWER COIL FOR AUTOMATIC DEFROST SYSTEM TO STOP COMPRESSOR BLOWER COIL FANS AND START HEATERS IN COIL. RUN CONDUIT ABOVE CEILING. THESE ITEMS ARE NOT PRE-WIRED AND WILL REQUIRE CONNECTIONS BY ELECTRICIAN AND FIELD WIRING.
AutoCAD SHX Text
2.
AutoCAD SHX Text
ELECTRICAL CONTRACTOR SHALL RUN CONTROL WIRING TO ROOF TOP UNITS, SENSORS, AND THERMOSTATS. COORDINATE WITH MECHANICAL CONTRACTOR.
AutoCAD SHX Text
3.
AutoCAD SHX Text
WEATHERPROOF MOTOR RATED SWITCH. PROVIDE 24" FLEXIBLE LOOP CONNECTION TO UNIT FOR MAINTENANCE.
AutoCAD SHX Text
4.
AutoCAD SHX Text
VERIFY LOCATION & NUMBER OF SIGNS WITH SIGN VENDOR. RUN SIGN CIRCUITS THROUGH CONTACTOR, CONTROLLED THROUGH PHOTOCELL. SEE DETAIL 5/E3.0. PROVIDE FLUSH MOUNTED WP J-BOX IN EXTERIOR FACE OF WALL. INSTALL PER NEC 600
AutoCAD SHX Text
5.
AutoCAD SHX Text
HVAC CONDENSATE DRAIN PIPING SHALL BE ROUTED DOWN THROUGH THE ROOF TO TERMINATION BELOW. REFER TO THE PLUMBING DWV PLAN FOR CONTINUATION OF CONDENSATE DRAINAGE PIPING BELOW THE ROOF.
AutoCAD SHX Text
6.
AutoCAD SHX Text
CONDENSATE DRAIN PIPING FROM THE HVAC UNIT SHALL BE ROUTED ON THE ROOF AS SHOWN, AT A MINIMUM PITCH OF 1/4" PER FOOT IN THE DIRECTION OF FLOW.
AutoCAD SHX Text
7.
AutoCAD SHX Text
GAS PIPING TO THE MECHANICAL UNIT SHALL BE ROUTED ON THE ROOF AS SHOWN. PROVIDE WEATHER TIGHT SEAL AT PIPE PENETRATION.
AutoCAD SHX Text
8.
AutoCAD SHX Text
ALL PIPING INSTALLED ON THE ROOF SHALL BE SUPPORTED WITH PRE-MANUFACTURED ADJUSTABLE PIPE SUPPORTS AT MAXIMUM 5'-0" ON CENTER AND EVERY CHANGE OF DIRECTION.
AutoCAD SHX Text
9.
AutoCAD SHX Text
ROOF MOUNTED VTR, SIZED AS SHOWN. INSTALLED LOCATION SHALL BE A MINIMUM OF 10'-0" FROM ANY OUTDOOR AIR INTAKE. TOP OF VTR STACK SHALL BE EVEN WITH PARAPET WALL.
AutoCAD SHX Text
10.
AutoCAD SHX Text
FIELD FABRICATED ROOF JACK FOR REFRIGERATION PIPING AND POWER CONDUIT(S) SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. REFER TO ARCHITECTURAL DETAILS FOR DIRECTION. THE MC, EC AND GC SHALL COORDINATE FOR A COMPLETE INSTALLATION.
AutoCAD SHX Text
11.
AutoCAD SHX Text
REMOTE CONDENSING UNIT SHALL BE INSTALLED ON MANUFACTURER APPROVED SLEEPERS. FIELD COORDINATE THE COMPLETE INSTALLATION.
AutoCAD SHX Text
12.
AutoCAD SHX Text
GAS PIPING SHALL BE ROUTED DOWN THROUGH THE ROOF. PROVIDE WEATHER TIGHT SEAL AT PIPE PENETRATION. REFER TO THE WATER AND GAS PLUMBING PLAN FOR CONTINUATION OF PIPING BELOW THE ROOF.
AutoCAD SHX Text
13.
AutoCAD SHX Text
ROUTE THE COMBUSTION AIR INTAKE/ EXHAUST PIPING FROM THE WATER HEATERS IN THE MECHANICAL ROOM TO TERMINATION LOCATIONS ON THE EXTERIOR WALL ABOVE THE DOOR. INSTALL WITH THE MINIMUM ELBOWS AND OFFSETS AS NECESSARY FOR A COMPLETE INSTALLATION PER THE WATER HEATER MANUFACTURER'S REQUIREMENTS, TERMINATED WITH THE HORIZONTAL PVC CONCENTRIC VENT KIT (SP20286). FIELD COORDINATE EXHAUST PIPING WITH CEILING LIGHT FIXTURE.
AutoCAD SHX Text
14.
AutoCAD SHX Text
CONTRACTOR SHALL PROVIDE ALL ELECTRICAL CONNECTIONS, WIRING AND CONDUITS NECESSARY FOR THE INTERLOCKING OF KITCHEN EXHAUST FANS AND MAKEUP AIR UNIT THROUGH THE KITCHEN CONTROL PANEL.
AutoCAD SHX Text
15.
AutoCAD SHX Text
WEATHERPROOF, WEATHER RESISTANT GFCI OUTLET PROVIDED WITH RTU TO BE WIRED TO CIRCUIT NOTED. CONDUIT AND WIRING TO RUN ABOVE FINISHED CEILING.
AutoCAD SHX Text
16.
AutoCAD SHX Text
WEATHERPROOF DISCONNECT SWITCH, 600V, 30A/3P/15AF/NEMA 3R, 3#12,#12G., IN 3/4"C. DOWN TO PRE-WIRED ELECTRICAL CONTROL PANEL ON KITCHEN HOOD.
AutoCAD SHX Text
17.
AutoCAD SHX Text
TRANSITION THE DUCTWORK HORIZONTALLY THEN THROUGH THE INTERIOR FACE OF THE PARAPET WALL AS SHOWN. THE ROOFING CONTRACTOR SHALL FLASH AND COUNTERFLASH THE DUCT PENETRATION FOR A WEATHER TIGHT SEAL. REFER TO THE MECHANICAL FLOOR PLAN FOR CONTINUATION OF DUCTWORK BELOW THE ROOF.
AutoCAD SHX Text
18.
AutoCAD SHX Text
REFER TO THE MECHANICAL SCHEDULE SHEET FOR PROPOSED MATERIALS INSTALLATION OF THE ROOF MOUNTED DUCTWORK.
AutoCAD SHX Text
19.
AutoCAD SHX Text
ROUTE ELECTRICAL POWER FOR EXHAUST FAN THROUGH RESTROOM LIGHTING CONTROLLER. COORDINATE AND PROVIDE ALL REQUIRED RELAYS AND CONTACTORS TO CIRCUIT EXHAUST WITH LIGHTING CONTROLS.
AutoCAD SHX Text
20.
AutoCAD SHX Text
ROUTE 3/4" COLD WATER UP THROUGH THE HVAC UNIT ROOF CURB, AND CONNECT TO HOSE BIBB MOUNTED ON THE SIDE OF THE ROOF CURB. REFER TO WATER AND GAS PLUMBING PLAN FOR CONTINUATION OF PIPING BELOW THE ROOF.
AutoCAD SHX Text
21.
AutoCAD SHX Text
WEATHERPROOF, GFCI OUTLET FOR CHRISTMAS STRING LIGHTS. PROVIDE WITH 'IN-USE' COVER.
AutoCAD SHX Text
PATIO HEATERS TO TERMINATION LOCATIONS ON THE ROOF. INSTALL WITH THE MINIMUM ELBOWS AND OFFSETS AS NECESSARY FOR A COMPLETE INSTALLATION PER THE HEATER MANUFACTURER'S REQUIREMENTS, TERMINATED WITH THE MANUFACTURER'S WEATHERPROOF ROOF VENT CAP. FIELD COORDINATE EXHAUST PIPING AND TERMINATIONS WITH ARCHITECTURAL ELEVATIONS. REFERENCE ARCHITECTURAL DETAILS FOR ROOF PENETRATION.
AutoCAD SHX Text
#
AutoCAD SHX Text
22.
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
Page 3: HAT CREEK BURGERCOMPANY

B

B

K.2

K.2

1

6

E.2

E.2

G

G

H

H

K.1

K.1

D

D

5

1.1

A.1

A.1

B.2

B.2

B.1

B.1

A

A

5.1

E

E

J

J

3

2.1

4

L

L

K

K

C

C

F

F

2

UP

ABOVE

ABOVE

1

MECHANICAL FLOOR PLAN

1/4"=1'-0"

MECHANICAL

FLOOR

PLAN

KEYED NOTES

REVISIONDATE

DATE:

SCALE:

DRAWN BY:

SHEET TITLE:

SHEET NUMBER:

REVISIONS

PRO

JEC

T:

07-02-21

STAFF

M1.0

HA

T C

REE

K B

UR

GER

CO

MPA

NY

ATH

ENS,

GEO

RG

IA

AS NOTED

14

90

1 Q

uo

ru

m D

r. #5

65

D

alla

s, T

X 75

25

4

rtm

asso

cia

tes.co

m | 9

72.3

87

.3

50

0

Sta

te

of G

eo

rg

ia

C

OA

: P

EF

00

68

38

08.09.2021 & Clarifications

Owner Changes

09.30.2021

Owner /Health

& City Comments

AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
1836
AutoCAD SHX Text
5
AutoCAD SHX Text
2442
AutoCAD SHX Text
5
AutoCAD SHX Text
2436
AutoCAD SHX Text
5
AutoCAD SHX Text
2442
AutoCAD SHX Text
5
AutoCAD SHX Text
2454
AutoCAD SHX Text
5
AutoCAD SHX Text
2442
AutoCAD SHX Text
5
AutoCAD SHX Text
2442
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
1836
AutoCAD SHX Text
5
AutoCAD SHX Text
C
AutoCAD SHX Text
G
AutoCAD SHX Text
G
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
trash
AutoCAD SHX Text
trash
AutoCAD SHX Text
G
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
1248
AutoCAD SHX Text
4
AutoCAD SHX Text
1442
AutoCAD SHX Text
5
AutoCAD SHX Text
1442
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
2448
AutoCAD SHX Text
5
AutoCAD SHX Text
16X14
AutoCAD SHX Text
20"
AutoCAD SHX Text
22"
AutoCAD SHX Text
20"
AutoCAD SHX Text
24X24
AutoCAD SHX Text
32X16
AutoCAD SHX Text
28X18
AutoCAD SHX Text
8"
AutoCAD SHX Text
100
AutoCAD SHX Text
GD2
AutoCAD SHX Text
300
AutoCAD SHX Text
KD1
AutoCAD SHX Text
400
AutoCAD SHX Text
KD1
AutoCAD SHX Text
(TYP FOR 2)
AutoCAD SHX Text
(TYP FOR 6)
AutoCAD SHX Text
150
AutoCAD SHX Text
GE
AutoCAD SHX Text
(TYP FOR 2)
AutoCAD SHX Text
314
AutoCAD SHX Text
DD
AutoCAD SHX Text
(TYP FOR 2)
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
8
AutoCAD SHX Text
4
AutoCAD SHX Text
1
AutoCAD SHX Text
16
AutoCAD SHX Text
7
AutoCAD SHX Text
6
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
9
AutoCAD SHX Text
12"
AutoCAD SHX Text
2
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
%%URTU-2
AutoCAD SHX Text
%%URTU-2
AutoCAD SHX Text
%%URTU-1
AutoCAD SHX Text
S
AutoCAD SHX Text
3
AutoCAD SHX Text
%%UHOOD-3
AutoCAD SHX Text
%%UHOOD-1
AutoCAD SHX Text
%%UHOOD-2
AutoCAD SHX Text
950
AutoCAD SHX Text
KR
AutoCAD SHX Text
15
AutoCAD SHX Text
(TYP FOR 3)
AutoCAD SHX Text
%%UKEF-1
AutoCAD SHX Text
%%UKEF-2
AutoCAD SHX Text
%%UKEF-3
AutoCAD SHX Text
%%UTEF-1
AutoCAD SHX Text
16"
AutoCAD SHX Text
500
AutoCAD SHX Text
KD1
AutoCAD SHX Text
(TYP FOR 4)
AutoCAD SHX Text
12"
AutoCAD SHX Text
10
AutoCAD SHX Text
S
AutoCAD SHX Text
10"
AutoCAD SHX Text
5
AutoCAD SHX Text
%%UFF-1
AutoCAD SHX Text
%%UUH-1
AutoCAD SHX Text
17
AutoCAD SHX Text
%%UMAU-1
AutoCAD SHX Text
S
AutoCAD SHX Text
18
AutoCAD SHX Text
20
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
(TYP FOR 6)
AutoCAD SHX Text
314
AutoCAD SHX Text
DD
AutoCAD SHX Text
12
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
200
AutoCAD SHX Text
KD2
AutoCAD SHX Text
(TYP FOR 2)
AutoCAD SHX Text
21
AutoCAD SHX Text
150
AutoCAD SHX Text
GD1
AutoCAD SHX Text
(TYP FOR 4)
AutoCAD SHX Text
285
AutoCAD SHX Text
DD
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
28X14
AutoCAD SHX Text
12"
AutoCAD SHX Text
16X14
AutoCAD SHX Text
6"
AutoCAD SHX Text
12"
AutoCAD SHX Text
22
AutoCAD SHX Text
%%UPH-1
AutoCAD SHX Text
%%UPH-2
AutoCAD SHX Text
%%UPH-3
AutoCAD SHX Text
%%UPH-4
AutoCAD SHX Text
19
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
23
AutoCAD SHX Text
16X14
AutoCAD SHX Text
22x22
AutoCAD SHX Text
14X14
AutoCAD SHX Text
10X12
AutoCAD SHX Text
10X12
AutoCAD SHX Text
20X18
AutoCAD SHX Text
24
AutoCAD SHX Text
24
AutoCAD SHX Text
24
AutoCAD SHX Text
24
AutoCAD SHX Text
H
AutoCAD SHX Text
25
AutoCAD SHX Text
H
AutoCAD SHX Text
25
AutoCAD SHX Text
18"
AutoCAD SHX Text
6"
AutoCAD SHX Text
10"
AutoCAD SHX Text
12"
AutoCAD SHX Text
12X10
AutoCAD SHX Text
2
AutoCAD SHX Text
10"
AutoCAD SHX Text
10"
AutoCAD SHX Text
8"
AutoCAD SHX Text
8"
AutoCAD SHX Text
(TYP FOR 2)
AutoCAD SHX Text
150
AutoCAD SHX Text
DD
AutoCAD SHX Text
26
AutoCAD SHX Text
1
AutoCAD SHX Text
ROUTE SUPPLY AND RETURN DUCTS DOWN FROM THE RTU CONNECTIONS AND TRANSITION THROUGH THE ROOF TO SIZES SHOWN. INSTALL COMPLETE WITH FLEXIBLE CONNECTIONS AT EQUIPMENT. PROVIDE 1/2" INTERNALLY LINED ACOUSTIC INSULATION FOR RETURN DUCTWORK AND THE FIRST 10'-0" OF SUPPLY DUCTWORK.
AutoCAD SHX Text
2
AutoCAD SHX Text
FACTORY AVAILABLE SMOKE DETECTOR CAPABLE OF SHUTTING DOWN THE RESPECTIVE MECHANICAL UNIT UPON ACTIVATION.
AutoCAD SHX Text
3
AutoCAD SHX Text
WALL MOUNTED REMOTE ZONE TEMPERATURE SENSOR SHALL BE MOUNTED AT 48" AFF, AND WIRED BACK TO RESPECTIVE 48" AFF, AND WIRED BACK TO RESPECTIVE , AND WIRED BACK TO RESPECTIVE PROGRAMMABLE THERMOSTAT IN MGR'S OFFICE. COORDINATE PLACEMENT WITH WALL DECOR AND EQUIPMENT. FIELD VERIFY WITH THE OWNER'S REPRESENTATIVE FOR THE FINAL LOCATION PRIOR TO INSTALLATION.
AutoCAD SHX Text
4
AutoCAD SHX Text
PROGRAMMABLE THERMOSTATS AT MANAGER'S DESK TO BE MOUNTED AT 60" AFF AND VERTICALLY STACKED AND CLEARLY LABELED. VERIFY PLACEMENT WITH ARCHITECTURAL FLOOR PLAN AND INTERIOR ELEVATIONS.
AutoCAD SHX Text
5
AutoCAD SHX Text
MANUAL PULL STATION FOR KITCHEN HOOD FIRE SUPPRESSION SYSTEM ACTIVATION AND GAS SUPPLY SHUT-OFF TO BE PROVIDED BY THE FIRE SUPPRESSION SUBCONTRACTOR. GENERAL CONTRACTOR SHALL PROVIDE RECESSED JUNCTION BOX AND CONDUIT FOR PULL STATION LINKAGE. FIRE SUPPRESSION SUBCONTRACTOR SHALL VERIFY APPROVED LOCATION WITH THE LOCAL AUTHORITY AND COORDINATE THE COMPLETE INSTALLATION WITH ALL OTHER TRADES.
AutoCAD SHX Text
6
AutoCAD SHX Text
FIRE SUPPRESSION CABINET TO BE FURNISHED WITH THE HOOD PACKAGE, AND INSTALLED BY THE MECHANICAL CONTRACTOR. FINAL PIPING AND LINKAGE CONNECTIONS TO BE MADE BY THE HOOD FIRE SUPPRESSION SUBCONTRACTOR.
AutoCAD SHX Text
7
AutoCAD SHX Text
ALL TYPE-1 GREASE EXHAUST DUCTS SHALL BE NFPA 96 APPROVED 16 GA. WELDED BLACK IRON, EXTERNALLY WELDED WITH LIQUID TIGHT JOINTS, SEAMS, AND SMOOTH RADIUS ELBOWS AND TRANSITIONS.
AutoCAD SHX Text
8
AutoCAD SHX Text
ALL TYPE-1 GREASE EXHAUST DUCTS SHALL BE DOUBLE WRAPPED WITH U.L. LISTED FIRE WRAP SIMILAR TO 3M FIRE BARRIER DUCT WRAP 20A IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. EACH GREASE DUCT RISER SHALL BE WRAPPED TO THE FULL EXTENT POSSIBLE FROM THE HOOD COLLAR CONNECTION UP TO THE TERMINATION AT THE EXHAUST FAN INLET. ALL GREASE EXHAUST FAN ROOF CURBS SHALL BE VENTED PER NFPA 96. PROVIDE REQUIRED ACCESS FOR SERVICING AND CLEANING, AND VERIFY THE HINGED CURB OPENING OPERATES PROPERLY. PITCH ALL HORIZONTAL EXHAUST DUCT A MINIMUM OF 1/4" PER FOOT BACK TOWARDS THE HOOD.
AutoCAD SHX Text
9
AutoCAD SHX Text
EXTEND THE 10" RESTROOM EXHAUST RISER UP TO ROOF MOUNTED 10" RESTROOM EXHAUST RISER UP TO ROOF MOUNTED EXHAUST FAN. FIELD VERIFY ANY REQUIRED TRANSITIONS OR OFFSETS FIELD VERIFY ANY REQUIRED TRANSITIONS OR OFFSETS OF EXHAUST DUCT FROM STRUCTURE.
AutoCAD SHX Text
10
AutoCAD SHX Text
THE 24x24 RETURN AIR DUCT SHALL BE INTERNALLY LINED. THE 24x24 RETURN AIR DUCT SHALL BE INTERNALLY LINED. THE RETURN AIR DUCT SHALL BE INTERNALLY LINED. THE RETURN PLENUM SHALL TERMINATE AT THE FACE OF THE WALL, ADJACENT TO THE SUPPLY MAIN. RETURN AIR INTAKE OPENING SHALL HAVE A MINIMUM FREE AREA OF 2.8 SQUARE FEET. PROVIDE 2.8 SQUARE FEET. PROVIDE SQUARE FEET. PROVIDE 1/4"x1/4" WIRE MESH SCREEN OVER INTAKE. PAINT THE INSIDE OF EXPOSED SHEET METAL DUCT BLACK FOR LINE OF SIGHT.
AutoCAD SHX Text
11
AutoCAD SHX Text
AIR DEVICE IN HARD LID CEILING SHALL BE INSTALLED COMPLETE WITH OPPOSED BLADE DAMPER FOR MANUAL VOLUME ADJUSTMENT.
AutoCAD SHX Text
12
AutoCAD SHX Text
AIR DEVICE SIDEWALL ON DUCT SHALL BE INSTALLED COMPLETE WITH OPPOSED BLADE DAMPER FOR MANUAL VOLUME ADJUSTMENT. FACE OF AIR DEVICE SHALL BE MOUNTED FLUSH TO THE FACE OF DUCT MOUNT.
AutoCAD SHX Text
13
AutoCAD SHX Text
ROUTE MAKEUP AIR DUCTWORK TO PERFORATED SUPPLY PLENUM COLLAR CONNECTION. MAKEUP AIR DUCT CONNECTION SHALL BE OF THE SAME SIZE AS THE PLENUM COLLAR. INSTALL WITH OPPOSED BLADE DAMPER FOR MANUAL VOLUME ADJUSTMENT.
AutoCAD SHX Text
14
AutoCAD SHX Text
ROUTE MAKEUP AIR DUCTWORK DOWN FULL SIZE FROM THE UNIT CONNECTION THROUGH THE ROOF AS SHOWN. PROVIDE FLEXIBLE CONNECTION AND TRANSITION THROUGH THE JOISTS AS REQUIRED.
AutoCAD SHX Text
15
AutoCAD SHX Text
RETURN GRILLE AIR QUANTITY LISTED IS FOR PARTIAL RETURN DURING STANDARD OPERATING HOURS. RETURN DUCTS ARE SIZED FOR FULL RETURN DURING NIGHT SETBACK CONDITIONS. REFER TO SHEET M2.0 SHEET M2.0 FOR AIR BALANCE REPORT ON DESIGN AIRFLOW RATES.
AutoCAD SHX Text
16
AutoCAD SHX Text
ALL EXPOSED DUCTWORK IN THE OPEN CEILING DINING AREA SHALL BE INSTALLED AS INTERNALLY INSULATED DUCT AND FITTINGS. DUCTWORK CONCEALED BY FINISHED WALLS AND CEILINGS SHALL TRANSITION TO EXTERNALLY INSULATED DUCT.
AutoCAD SHX Text
17
AutoCAD SHX Text
UNIT HEATER SHALL BE MOUNTED ON FACTORY AVAILABLE WALL BRACKET, AS HIGH AS POSSIBLE FOR CLEARANCE ABOVE THE DOOR JAMB. ANGLE THE DISCHARGE FACE DOWN TOWARDS THE WATER PIPING.
AutoCAD SHX Text
18
AutoCAD SHX Text
REMOTE ZONE TEMPERATURE SENSOR SHALL BE MOUNTED AT 15'-6" ON WALL NEAR RETURN AIR GRILL FOR RTU-1 AND WIRED BACK TO RESPECTIVE PROGRAMMABLE THERMOSTAT IN MGR'S AREA. COORDINATE PLACEMENT WITH WALL DECOR AND EQUIPMENT. FIELD VERIFY WITH THE OWNER'S REPRESENTATIVE FOR THE FINAL LOCATION PRIOR TO INSTALLATION.
AutoCAD SHX Text
19
AutoCAD SHX Text
GAS FIRED PATIO HEATER SHALL BE MOUNTED ON FACTORY AVAILABLE BRACKET, WITH THE APPLIANCE LOCATED PER MANUFACTURER'S RECOMMENDATIONS FOR CLEARANCE WITH COMBUSTIBLES. ANGLE THE APPLIANCE AT 30° TO THE HORIZONTAL, TO MAXIMIZE AREA COVERAGETO THE PATIO SEATING.
AutoCAD SHX Text
20
AutoCAD SHX Text
ROUTE THE COMBUSTION AIR INTAKE/ EXHAUST PIPING FROM THE WATER HEATERS IN THE MECHANICAL ROOM TO TERMINATION LOCATIONS ON THE EXTERIOR WALL ABOVE THE DOOR. INSTALL WITH THE MINIMUM ELBOWS AND OFFSETS AS NECESSARY FOR A COMPLETE INSTALLATION PER THE WATER HEATER MANUFACTURER'S REQUIREMENTS, TERMINATED WITH THE HORIZONTAL CONCENTRIC VENT KIT. FIELD COORDINATE EXHAUST PIPING WITH CEILING LIGHT FIXTURE.
AutoCAD SHX Text
21
AutoCAD SHX Text
ROUTE BRANCH DUCT ABOVE THE SOFFIT AND OVER THE BEAM IN THIS AREA. THEN ROUTE DUCT DOWN AND OUT IN THE QUEUE LINE AREA.
AutoCAD SHX Text
22
AutoCAD SHX Text
ROUTE MAIN BRANCH OF MAKEUP AIR DUCT UP HIGH BETWEEN JOISTS. BRANCHES TO THE HOODS SHALL DROP BELOW THE JOISTS AND TO THE PLENUM CONNECTIONS.
AutoCAD SHX Text
23
AutoCAD SHX Text
PATIO HEATERS SHALL HAVE PROGRAMMABLE THERMOSTAT SET SUCH THAT DURING UNOCCUPIED HOURS ACTIVATE IF SPACE TEMPERATURE IS 50 DEGREES OR BELOW.
AutoCAD SHX Text
#
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
21.WMA.037
AutoCAD SHX Text
24
AutoCAD SHX Text
FLUE THRU ROOF WITH ROOF FLASHING, CAP AND COLLAR. CONTRACTOR TO COORDINATE INSTALLATION WITH ROOFING CONTRACTOR.
AutoCAD SHX Text
25
AutoCAD SHX Text
HEATING AND COOLING TO EACH ZONE IS CONTROLLED BY A THERMOSTAT CONTROL (HUMIDISTATS) MINIMUM ONE HUMIDITY CONTROL DEVICE PER INSTALLED HUMIDIFICATION/ DEHUMIDIFICATION SYSTEM.
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
26
AutoCAD SHX Text
AIR DEVICE IN SIDEWALL SOFFIT SHALL BE INSTALLED COMPLETE WITH OPPOSED BLADE DAMPER FOR MANUAL VOLUME ADJUSTMENT. FACE OF AIR DEVICE SHALL BE MOUNTED FLUSH TO THE FACE OF WALL.
AutoCAD SHX Text
2
Page 4: HAT CREEK BURGERCOMPANY

MECHANICAL

SCHEDULES

MECHANICAL LEGEND

AIR BALANCE SCHEDULE

MECHANICAL GENERAL NOTES

FAN SCHEDULE

AIR DEVICE SCHEDULE

O/A VENTILATION SCHEDULEFLY FAN SCHEDULE

ELECTRIC HEATER SCHEDULE

REVISIONDATE

DATE:

SCALE:

DRAWN BY:

SHEET TITLE:

SHEET NUMBER:

REVISIONS

PRO

JEC

T:

07-02-21

STAFF

M2.0

HA

T C

REE

K B

UR

GER

CO

MPA

NY

ATH

ENS,

GEO

RG

IA

AS NOTED

149

01

Q

uoru

m D

r. #

56

5 D

alla

s, T

X 75

25

4

rtm

asso

cia

te

s.co

m | 9

72

.3

87

.3

50

0

Sta

te o

f G

eo

rg

ia

C

OA

: P

EF

00

68

38

PACKAGED ROOFTOP UNIT SCHEDULEGAS HEATER SCHEDULE

08.09.2021 & Clarifications

Owner Changes

AutoCAD SHX Text
T
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
300
AutoCAD SHX Text
FOH (CFM)
AutoCAD SHX Text
BOH (CFM)
AutoCAD SHX Text
S/A
AutoCAD SHX Text
O/A
AutoCAD SHX Text
E/A
AutoCAD SHX Text
S/A
AutoCAD SHX Text
O/A
AutoCAD SHX Text
E/A
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
DINING PRESSURIZATION (O/A) - (E/A)=
AutoCAD SHX Text
900 CFM
AutoCAD SHX Text
KITCHEN PRESSURIZATION (O/A) - (E/A)=
AutoCAD SHX Text
-110 CFM
AutoCAD SHX Text
NET BUILDING PRESSURIZATION (DINING + KITCHEN)=
AutoCAD SHX Text
+790 CFM
AutoCAD SHX Text
RTU-1
AutoCAD SHX Text
RTU-2
AutoCAD SHX Text
KEF-1
AutoCAD SHX Text
KEF-2
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
1125
AutoCAD SHX Text
1200
AutoCAD SHX Text
300
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
4000
AutoCAD SHX Text
4940
AutoCAD SHX Text
5050
AutoCAD SHX Text
MARK
AutoCAD SHX Text
5000
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
CEILING DIFFUSER - SUPPLY
AutoCAD SHX Text
CEILING DIFFUSER BELOW DUCT - SUPPLY
AutoCAD SHX Text
RISER - SUPPLY AIR DUCT
AutoCAD SHX Text
DROP - SUPPLY AIR DUCT
AutoCAD SHX Text
CEILING REGISTER - RETURN
AutoCAD SHX Text
CEILING REGISTER BELOW DUCT - RETURN
AutoCAD SHX Text
RISER - RETURN AIR DUCT
AutoCAD SHX Text
DROP - RETURN AIR DUCT
AutoCAD SHX Text
CEILING REGISTER - EXHAUST
AutoCAD SHX Text
CEILING REGISTER BELOW DUCT - EXHAUST
AutoCAD SHX Text
RISER - EXHAUST AIR DUCT
AutoCAD SHX Text
LINED DUCTWORK
AutoCAD SHX Text
MANUAL VOLUME DAMPER
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
NEW DUCT
AutoCAD SHX Text
AIR DEVICE DESIGNATION
AutoCAD SHX Text
PROGRAMMABLE THERMOSTAT
AutoCAD SHX Text
REMOTE TEMPERATURE SENSOR
AutoCAD SHX Text
POINT OF CONNECTION
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
CD
AutoCAD SHX Text
CD
AutoCAD SHX Text
SAD
AutoCAD SHX Text
SAD
AutoCAD SHX Text
CR
AutoCAD SHX Text
CR
AutoCAD SHX Text
RAD
AutoCAD SHX Text
RAD
AutoCAD SHX Text
CE
AutoCAD SHX Text
CE
AutoCAD SHX Text
EAD
AutoCAD SHX Text
(L)
AutoCAD SHX Text
VD
AutoCAD SHX Text
FC
AutoCAD SHX Text
TSTAT
AutoCAD SHX Text
SENS
AutoCAD SHX Text
SD
AutoCAD SHX Text
POC
AutoCAD SHX Text
CFM
AutoCAD SHX Text
S/A
AutoCAD SHX Text
O/A
AutoCAD SHX Text
E/A
AutoCAD SHX Text
S.P.
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
ABBR.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
1
AutoCAD SHX Text
NOTE: FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZES AND LOCATIONS OF EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, THE CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL OF THE CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION PRIOR TO ORDERING, FABRICATING OR INSTALLING ANY MATERIALS.
AutoCAD SHX Text
2
AutoCAD SHX Text
THE MECHANICAL CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATE WITH THE OTHER CONTRACTORS AND TRADES AS REQUIRED FOR THE COMPLETION AND COORDINATION OF THE COMPLETE PROJECT.
AutoCAD SHX Text
3
AutoCAD SHX Text
THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADMINISTERING ALL WARRANTIES ON EQUIPMENT WHICH THEY FURNISH AND INSTALL.
AutoCAD SHX Text
4
AutoCAD SHX Text
PROVIDE WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND/OR LABOR, AT NO COST TO TENANT, FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE.
AutoCAD SHX Text
5
AutoCAD SHX Text
PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE DUCT/ PIPING CONNECTIONS TO ALL MOVING MACHINERY NOT INTERNALLY ISOLATED.
AutoCAD SHX Text
6
AutoCAD SHX Text
ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS.
AutoCAD SHX Text
7
AutoCAD SHX Text
THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER LOCATIONS WITH SPRINKLER PIPING, SPRINKLER HEADS AND LIGHT FIXTURES AS REQUIRED FOR A COMPLETE INSTALLATION.
AutoCAD SHX Text
8
AutoCAD SHX Text
THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES ALL REQUIRED OPENINGS AND PENETRATIONS. ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, WALLS AND ROOF SHALL BE CONSTRUCTED INTO THE STRUCTURE WITH THE USE OF SLEEVES, CURBS, ETC. CUTTING AND PATCHING SHALL BE HELD TO A MINIMUM.
AutoCAD SHX Text
9
AutoCAD SHX Text
ALL ITEMS PROJECTING THROUGH THE ROOF SHALL BE FLASHED THROUGH CURBS OR PIPE SEALS A MINIMUM OF 12" ABOVE THE ROOF. THE PIPE CURBS AND SEALS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR. ENSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE ANY ELECTRICAL CONDUIT PENETRATIONS REQUIRED FOR POWER.
AutoCAD SHX Text
10
AutoCAD SHX Text
COORDINATE THE INSTALLATION AND FINISH OF ALL SUPPLY AND RETURN AIR DEVICES. AIR DEVICES LOCATED IN GUEST AREAS (INCLUDING DINING AND BAR) SHALL BE PAINTED PER THE ARCHITECTURAL DRAWINGS FINISH SCHEDULE. ALL INTERIOR FACES OF DUCTWORK BEHIND RETURN AIR GRILLES SHALL BE PAINTED FLAT BACK FOR LINE OF SIGHT.
AutoCAD SHX Text
11
AutoCAD SHX Text
THERMOSTATS AND REMOTE SENSORS SHALL BE LOCATED AT 60" A.F.F. EXACT LOCATIONS SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL-MOUNTED WORK OR PROXIMITY TO HEAT PRODUCING EQUIPMENT.
AutoCAD SHX Text
12
AutoCAD SHX Text
ALL SUPPLY, RETURN, AND RESTROOM EXHAUST DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE UNDER THE ROOF STRUCTURE.
AutoCAD SHX Text
13
AutoCAD SHX Text
ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS SHOWN ON THESE DRAWINGS; AND SHALL BE FABRICATED AND INSTALLED ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA STANDARDS. ALL JOINTS, SEAMS, AND CONNECTIONS MUST BE SECURELY FASTENED & SEALED BY APPROVED METHODS.
AutoCAD SHX Text
14
AutoCAD SHX Text
ANY FLEXIBLE DUCTS SHALL BE INSTALLED IN CONCEALED SPACES ONLY. THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0". ALL FLEXIBLE DUCTS SHALL BE CONNECTED TO BRANCH RUNS AND FITTINGS WITH A PANDUIT-TYPE BAND, AND SHALL NOT BE ATTACHED DIRECTLY TO THE AIR DEVICE COLLAR.
AutoCAD SHX Text
15
AutoCAD SHX Text
ROOFTOP UNITS SHALL BE SET TO RUN IN "FAN CONTINUOUS" MODE DURING OCCUPIED HOURS. DURING NIGHT SET-BACK HOURS, THE ROOFTOP UNITS SHALL RUN IN "FAN AUTO" MODE.
AutoCAD SHX Text
16
AutoCAD SHX Text
MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL 4" HIGH BLACK OVER WHITE LAMINATE NAMEPLATE WITH 2" LETTERS VISIBLE ADJACENT TO DISCONNECT SWITCH FOR ROOFTOP UNITS AND ROOF MOUNTED FANS.
AutoCAD SHX Text
17
AutoCAD SHX Text
LINE VOLTAGE WIRING, ALL CONDUIT DISCONNECT SWITCHES AND FINAL CONNECTION BY ELECTRICAL CONTRACTOR. LOW VOLTAGE CONDUIT AND WIRING AND FINAL CONNECTION BY MECHANICAL CONTRACTOR.
AutoCAD SHX Text
18
AutoCAD SHX Text
CONCEALED DUCTWORK WITHIN THE BUILDING SHALL BE EXTERNALLY WRAPPED DUCTWORK WITHIN THE BUILDING SHALL BE EXTERNALLY WRAPPED AND SECURED WITH MINIMUM R-8.0, 2" INSULATION WITH VAPOR BARRIER PER MINIMUM R-8.0, 2" INSULATION WITH VAPOR BARRIER PER INSULATION WITH VAPOR BARRIER PER INSULATION WITH VAPOR BARRIER PER THE 2018 INTERNATIONAL MECHANICAL CODE, WITH LOCAL AMENDMENTS. . INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED.
AutoCAD SHX Text
19
AutoCAD SHX Text
ALL PENETRATIONS IN FIRE RATED WALL ASSEMBLIES SHALL BE SEALED WITH UL LISTED FIRE STOPPING MATERIAL.
AutoCAD SHX Text
20
AutoCAD SHX Text
SUPPLY, RETURN, RESTROOM EXHAUST, AND MAKEUP AIR DUCT CONSTRUCTION SHALL BE GALVANIZED STEEL. GAUGES, SWAY BRACING (AS REQUIRED) AND SUSPENSION SHALL CONFORM TO SMACNA STANDARDS. SEAL ALL SEAMS AND JOINTS AIR AND WATERTIGHT. FLEXIBLE ALUMINUM DUCTWORK OR FIBERGLASS DUCTBOARD IS NOT ALLOWED (UNO).
AutoCAD SHX Text
21
AutoCAD SHX Text
ALL GREASE EXHAUST FAN ROOF CURBS SHALL BE VENTED PER NFPA 96. PROVIDE REQUIRED ACCESS FOR SERVICING AND CLEANING, AND VERIFY THE HINGED CURB OPENING OPERATES PROPERLY.
AutoCAD SHX Text
22
AutoCAD SHX Text
ROOF CURBS FOR EXHAUST FANS AND THE MAKEUP AIR UNIT SHALL BE FACTORY FABRICATED AND FURNISHED WITH THE HOOD PACKAGE. VERIFY REQUIREMENTS FOR THE ROOF CURBS WITH THE EQUIPMENT SUPPLIER. THE GENERAL CONTRACTOR SHALL FLASH ROOF CURBS AND SHIM DEAD LEVEL. COORDINATE EXACT SIZE AND LOCATION OF ROOF OPENINGS WITH THE STRUCTURAL FRAMING. CUTTING OF STRUCTURAL MEMBERS IS NOT PERMITTED.
AutoCAD SHX Text
23
AutoCAD SHX Text
ROOF CURBS FOR ROOFTOP UNITS SHALL BE FACTORY FABRICATED OF FULL WELDED STEEL CONSTRUCTION WITH WOOD NAILER, AND FURNISHED WITH THE HVAC EQUIPMENT PACKAGE. VERIFY REQUIREMENTS FOR THE ROOF CURBS WITH THE EQUIPMENT SUPPLIER. THE GENERAL CONTRACTOR SHALL FIELD ASSEMBLE THE ROOF CURBS, FLASH AND SHIM DEAD LEVEL. COORDINATE EXACT SIZE AND LOCATION OF ROOF OPENINGS WITH THE STRUCTURAL FRAMING. CUTTING OF STRUCTURAL MEMBERS IS NOT PERMITTED.
AutoCAD SHX Text
24
AutoCAD SHX Text
THE KITCHEN EXHAUST HOODS SHALL BE INSTALLED AT 6'-8" AFF (UNO). 6'-8" AFF (UNO). (UNO). COORDINATE THE INSTALLATION AND PLACEMENT OF THE EXHAUST HOODS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN.
AutoCAD SHX Text
25
AutoCAD SHX Text
THE KITCHEN HOOD PACKAGE WILL BE PROVIDED WITH UTILITY END CABINETS HOUSING THE FIRE SUPPRESSION TANKS, ELECTRICAL PREWIRE PACKAGE, HOOD EXHAUST FAN SWITCHES, AND LIGHT SWITCHES.
AutoCAD SHX Text
26
AutoCAD SHX Text
THE GREASE EXHAUST DUCT RISERS BETWEEN THE HOOD COLLARS AND EXHAUST FANS SHALL BE OF THE SAME SIZE AS THE RESPECTIVE FIELD CUT HOOD COLLAR SIZE, UNO. REFER TO THE HOOD SHEETS FOR THE HOOD COLLAR SIZES AS SPECIFIED BY THE HOOD MANUFACTURER.
AutoCAD SHX Text
27
AutoCAD SHX Text
THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING THE AIR FILTERS AT THE ROOFTOP UNITS WITH 2" THICK PLEATED MERV 8 THROW MERV 8 THROW THROW AWAY TYPE AIR FILTERS AT THE COMPLETION OF CONSTRUCTION AND PRIOR TO AIR BALANCE AND STORE TURNOVER.
AutoCAD SHX Text
28
AutoCAD SHX Text
PER 2018 INTERNATIONAL MECHANICAL CODE, WITH LOCAL AMENDMENTS WHEN 2018 INTERNATIONAL MECHANICAL CODE, WITH LOCAL AMENDMENTS WHEN WHEN REQUIRED, EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN EXCESS OF 2000 CUBIC FEET PER MINUTE SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF. AUTOMATIC SHUTOFF SHALL BE ACCOMPLISHED BY INTERRUPTING THE POWER SOURCE OF THE AIR MOVING EQUIPMENT DEVICES WHICH WILL DETECT PRODUCTS OF COMBUSTION OTHER THAN HEAT, AND WHICH COMPLY WITH THE UBC, SHALL BE LABELED BY AN APPROVED AGENCY FOR AIR DUCT INSTALLATION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SUCH DEVICES SHALL BE COMPATIBLE WITH THE OPERATING VELOCITIES, PRESSURES, TEMPERATURES AND HUMIDITIES OF THE SYSTEM WHERE FIRE DETECTION OR ALARM SYSTEMS ARE PROVIDED FOR THE BUILDING, SMOKE DETECTORS SHALL BE SUPERVISED BY SUCH SYSTEMS.
AutoCAD SHX Text
29
AutoCAD SHX Text
MECHANICAL CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER.
AutoCAD SHX Text
30
AutoCAD SHX Text
A FULL MECHANICAL AIR TEST AND BALANCE REPORT SHALL BE PERFORMED BY A 3RD PARTY TAB CONTRACTOR.
AutoCAD SHX Text
31
AutoCAD SHX Text
EXPOSED DUCTWORK WITHIN THE BUILDING SHALL BE INTERNALLY LINED AND DUCTWORK WITHIN THE BUILDING SHALL BE INTERNALLY LINED AND PINNED WITH MINIMUM R-6.0, 1-1/2" INSULATION WITH VAPOR BARRIER PER MINIMUM R-6.0, 1-1/2" INSULATION WITH VAPOR BARRIER PER INSULATION WITH VAPOR BARRIER PER THE 2018 INTERNATIONAL MECHANICAL CODE WITH LOCAL AMENDMENTS. . INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. EXPOSED DUCTWORK SHALL BE INSTALLED COMPLETE WITH FACTORY APPLIED PAINT GRIP FINISH, SUITABLE FOR FINAL FIELD APPLIED PAINT BY THE GENERAL CONTRACTOR.
AutoCAD SHX Text
32
AutoCAD SHX Text
ROOF MOUNTED DUCTWORK ON THE BUILDING SHALL BE EXTERNALLY DUCTWORK ON THE BUILDING SHALL BE EXTERNALLY WRAPPED AND SECURED WITH MINIMUM R-8.0, 2" INSULATION WITH VAPOR MINIMUM R-8.0, 2" INSULATION WITH VAPOR INSULATION WITH VAPOR INSULATION WITH VAPOR BARRIER PER THE 2018 INTERNATIONAL MECHANICAL CODE, WITH LOCAL THE 2018 INTERNATIONAL MECHANICAL CODE, WITH LOCAL AMENDMENTS. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME . INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. INSTALL COMPLETE WITH A FINAL EXTERIOR LAYER OF CORROSION RESISTANT 24 GA. GALVANIZED SHEET METAL WITH A 1/12 TOP PITCH TO PREVENT STANDING WATER.
AutoCAD SHX Text
KEF-3
AutoCAD SHX Text
TEF-1
AutoCAD SHX Text
4000
AutoCAD SHX Text
900
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
1450
AutoCAD SHX Text
1800
AutoCAD SHX Text
1800
AutoCAD SHX Text
MAU-1
AutoCAD SHX Text
-
AutoCAD SHX Text
4040
AutoCAD SHX Text
FRONT OF HOUSE
AutoCAD SHX Text
FOH
AutoCAD SHX Text
BACK OF HOUSE
AutoCAD SHX Text
BOH
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
5000
AutoCAD SHX Text
1.
AutoCAD SHX Text
2.
AutoCAD SHX Text
WEATHER PROOF DISCONNECT SWITCH AND INTERNAL WIRING SHALL BE FACTORY INSTALLED.
AutoCAD SHX Text
3.
AutoCAD SHX Text
%%UNOTES%%U:
AutoCAD SHX Text
THE FAN SHALL BE FACTORY EQUIPPED WITH AN INDEPENDENT WEATHER PROOF DISCONNECT SWITCH IN SIGHT OF THE EQUIPMENT.
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
VOLTS/PH
AutoCAD SHX Text
MOTOR HP
AutoCAD SHX Text
RPM
AutoCAD SHX Text
E.S.P. "WG
AutoCAD SHX Text
CFM
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
KEF-1
AutoCAD SHX Text
KEF-2
AutoCAD SHX Text
TEF-1
AutoCAD SHX Text
KEF-3
AutoCAD SHX Text
FRYERS
AutoCAD SHX Text
2,4,7
AutoCAD SHX Text
HOOD #1
AutoCAD SHX Text
PUBLIC RESTROOMS
AutoCAD SHX Text
3,4,6
AutoCAD SHX Text
HOOD #2
AutoCAD SHX Text
1,2,3,5,6
AutoCAD SHX Text
1800
AutoCAD SHX Text
1278
AutoCAD SHX Text
CAPTIVEAIRE
AutoCAD SHX Text
124
AutoCAD SHX Text
208/3
AutoCAD SHX Text
ROOF UPBLAST FAN
AutoCAD SHX Text
1,2,3,5,6
AutoCAD SHX Text
1.2
AutoCAD SHX Text
1.0
AutoCAD SHX Text
1800
AutoCAD SHX Text
1278
AutoCAD SHX Text
124
AutoCAD SHX Text
208/3
AutoCAD SHX Text
ROOF UPBLAST FAN
AutoCAD SHX Text
1.0
AutoCAD SHX Text
1450
AutoCAD SHX Text
1293
AutoCAD SHX Text
1.2
AutoCAD SHX Text
1.0
AutoCAD SHX Text
300
AutoCAD SHX Text
1250
AutoCAD SHX Text
68
AutoCAD SHX Text
G099VG
AutoCAD SHX Text
ROOF DOWNBLAST FAN
AutoCAD SHX Text
0.50
AutoCAD SHX Text
0.25
AutoCAD SHX Text
MAU-1
AutoCAD SHX Text
1,2,3,6
AutoCAD SHX Text
COOKLINE HOODS
AutoCAD SHX Text
4040
AutoCAD SHX Text
677
AutoCAD SHX Text
362
AutoCAD SHX Text
A2-D.250-20D
AutoCAD SHX Text
ROOF MAKEUP FAN
AutoCAD SHX Text
0.65
AutoCAD SHX Text
2.0
AutoCAD SHX Text
1.2
AutoCAD SHX Text
115/1
AutoCAD SHX Text
208/3
AutoCAD SHX Text
OWNER FURNISHED WITH HOOD PACKAGE, INSTALLED BY MECHANICAL CONTRACTOR.
AutoCAD SHX Text
THE UTILITY CABINET SHALL BE FACTORY EQUIPPED WITH A PREWIRE PACKAGE TO INTERLOCK THE FRONT COOKLINE EXHAUST FANS WITH THE MAKEUP AIR UNIT.
AutoCAD SHX Text
THE FAN SHALL BE FACTORY EQUIPPED WITH A GRAVITY BACKDRAFT DAMPER.
AutoCAD SHX Text
4.
AutoCAD SHX Text
5.
AutoCAD SHX Text
6.
AutoCAD SHX Text
CAPTIVEAIRE
AutoCAD SHX Text
CAPTIVEAIRE
AutoCAD SHX Text
GREENHECK
AutoCAD SHX Text
CAPTIVEAIRE
AutoCAD SHX Text
THE FAN SHALL BE SUPPLIED WITH FACTORY CURBS.
AutoCAD SHX Text
ND-2-PSP-F
AutoCAD SHX Text
MARK
AutoCAD SHX Text
FACE SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MOUNTING TYPE
AutoCAD SHX Text
MAXIMUM N.C.
AutoCAD SHX Text
DIRECTION
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
%%UNOTES:%%U
AutoCAD SHX Text
1.AIR DEVICES MOUNTED ON A WHITE SURFACE IN BACK OF HOUSE SHALL BE INSTALLED WITH FACTORY APPLIED AIR DEVICES MOUNTED ON A WHITE SURFACE IN BACK OF HOUSE SHALL BE INSTALLED WITH FACTORY APPLIED OFF WHITE FINISH. 2.AIR DEVICES IN THE FRONT OF HOUSE SHALL BE INSTALLED WITH FACTORY MIL FINISH. THE PAINTING CONTRACTOR AIR DEVICES IN THE FRONT OF HOUSE SHALL BE INSTALLED WITH FACTORY MIL FINISH. THE PAINTING CONTRACTOR SHALL APPLY PAINT GRIP PRIMER SUITABLE FOR FINAL PAINT FINISH AS DETERMINED ON THE ARCHITECTURAL DRAWINGS. 3.PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED FOR INTENDED INSTALLATION. PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED FOR INTENDED INSTALLATION. 4.AIR DEVICE SHALL BE INSTALLED WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD FABRICATED AIR DEVICE SHALL BE INSTALLED WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD FABRICATED INSULATION BACKING IS NOT ALLOWED (UNLESS FIRST APPROVED BY THE OWNER'S CONSTRUCTION MANAGER). 5.AIR DEVICE NEAR THE EXHAUST HOOD CANOPY SHALL BE INSTALLED COMPLETE WITHOUT SUPPLY AIR FLOW AIR DEVICE NEAR THE EXHAUST HOOD CANOPY SHALL BE INSTALLED COMPLETE WITHOUT SUPPLY AIR FLOW PATTERN CONTROLLERS, TO PREVENT INTERFERENCE WITH EXHAUST CAPTURE AND CONTAINMENT. 6.AIR DEVICE SHALL BE INSTALLED WITH ACCESSIBLE OPPOSED BLADE DAMPER FOR MANUAL VOLUME ADJUSTMENT.AIR DEVICE SHALL BE INSTALLED WITH ACCESSIBLE OPPOSED BLADE DAMPER FOR MANUAL VOLUME ADJUSTMENT.
AutoCAD SHX Text
DD
AutoCAD SHX Text
2,3,4,6
AutoCAD SHX Text
GE
AutoCAD SHX Text
EXHAUST
AutoCAD SHX Text
30
AutoCAD SHX Text
1-WAY
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
2,3,6
AutoCAD SHX Text
12x12
AutoCAD SHX Text
SURFACE (GYP. CLG)
AutoCAD SHX Text
3FL
AutoCAD SHX Text
KD1
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
30
AutoCAD SHX Text
1-WAY
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
1,3,5
AutoCAD SHX Text
24x24
AutoCAD SHX Text
LAY-IN
AutoCAD SHX Text
PAR-AA
AutoCAD SHX Text
GD1
AutoCAD SHX Text
KR
AutoCAD SHX Text
RETURN
AutoCAD SHX Text
30
AutoCAD SHX Text
1-WAY
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
1,2,3
AutoCAD SHX Text
24x24
AutoCAD SHX Text
LAY-IN/ SURFACE
AutoCAD SHX Text
PAR-AA
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
30
AutoCAD SHX Text
4-WAY
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
2,3,4
AutoCAD SHX Text
24X24
AutoCAD SHX Text
OMNI
AutoCAD SHX Text
FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR.
AutoCAD SHX Text
7.
AutoCAD SHX Text
CFM
AutoCAD SHX Text
TAG
AutoCAD SHX Text
AREA SERVED
AutoCAD SHX Text
833
AutoCAD SHX Text
111
AutoCAD SHX Text
DINING
AutoCAD SHX Text
7.5
AutoCAD SHX Text
-
AutoCAD SHX Text
RESTROOMS
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
TOTAL O/A
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
%%uNOTES:
AutoCAD SHX Text
CALCULATIONS ARE BASED ON 2018 IMC 2018 IMC 1.OUTDOOR AIR DEMAND IS: - 1043 CFM OUTDOOR AIR DEMAND IS: - 1043 CFM - 1043 CFM OUTDOOR AIR PROVIDED IS: + 1200 CFM + 1200 CFM ----------------------------- OUTDOOR AIR DIFFERENCE IS:+ 157 CFM+ 157 CFM
AutoCAD SHX Text
# OF PEOPLE
AutoCAD SHX Text
CFM/PERSON
AutoCAD SHX Text
CFM
AutoCAD SHX Text
VENTILATION (OCCUPANCY)
AutoCAD SHX Text
210
AutoCAD SHX Text
1168
AutoCAD SHX Text
0.18
AutoCAD SHX Text
-
AutoCAD SHX Text
193
AutoCAD SHX Text
-
AutoCAD SHX Text
SQUARE FEET
AutoCAD SHX Text
CFM/SF
AutoCAD SHX Text
CFM
AutoCAD SHX Text
VENTILATION (AREA)
AutoCAD SHX Text
-
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
769
AutoCAD SHX Text
-
AutoCAD SHX Text
SUBTOTALS
AutoCAD SHX Text
833
AutoCAD SHX Text
210
AutoCAD SHX Text
1043 CFM
AutoCAD SHX Text
16x4 (DUCT SIZE)
AutoCAD SHX Text
30
AutoCAD SHX Text
2-WAY
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
US300FL
AutoCAD SHX Text
DUCT MOUNTED
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
SURFACE (GYP. CLG)
AutoCAD SHX Text
GD2
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
30
AutoCAD SHX Text
4-WAY
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
2,3,4
AutoCAD SHX Text
12X12
AutoCAD SHX Text
OMNI
AutoCAD SHX Text
SURFACE (GYP. CLG)
AutoCAD SHX Text
ROOF UPBLAST FAN
AutoCAD SHX Text
124
AutoCAD SHX Text
208/3
AutoCAD SHX Text
FF-1
AutoCAD SHX Text
1418
AutoCAD SHX Text
MARS
AutoCAD SHX Text
60
AutoCAD SHX Text
REAR SERVICE DOOR
AutoCAD SHX Text
5.0 / 20
AutoCAD SHX Text
WALL MNTD, DOWNBLAST
AutoCAD SHX Text
1 THRU 3
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MCA/MOCP
AutoCAD SHX Text
CFM
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
115/1
AutoCAD SHX Text
VOLTS/ PH
AutoCAD SHX Text
10.75"
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
LPN242-1UA-OB
AutoCAD SHX Text
1.INSTALL COMPLETE WITH MANUFACTURER AVAILABLE DOOR LIMIT MICRO SWITCH. INSTALL COMPLETE WITH MANUFACTURER AVAILABLE DOOR LIMIT MICRO SWITCH. 2.UNIT SHALL BE BLACK IN COLOR. UNIT SHALL BE BLACK IN COLOR. 3.FAN SHALL BE FURNISHED AND INSTALLED BY KITCHEN EQUIPMENT SUPPLIER.FAN SHALL BE FURNISHED AND INSTALLED BY KITCHEN EQUIPMENT SUPPLIER.
AutoCAD SHX Text
KD2
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
30
AutoCAD SHX Text
1-WAY
AutoCAD SHX Text
TITUS
AutoCAD SHX Text
1,3,5
AutoCAD SHX Text
12x12
AutoCAD SHX Text
LAY-IN
AutoCAD SHX Text
PAR-AA
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
MARK
AutoCAD SHX Text
HEATING
AutoCAD SHX Text
CAPACITY
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
CFM
AutoCAD SHX Text
1,2,3
AutoCAD SHX Text
MUH05-81
AutoCAD SHX Text
QMARK
AutoCAD SHX Text
208 / 1
AutoCAD SHX Text
UNIT/CABINET
AutoCAD SHX Text
UH-1
AutoCAD SHX Text
5.0 kW
AutoCAD SHX Text
350
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
VOLT / PH
AutoCAD SHX Text
NOTES: :
AutoCAD SHX Text
1.COORDINATE POWER AND DISCONNECT REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. COORDINATE POWER AND DISCONNECT REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 2.INSTALL COMPLETE WITH MANUFACTURER AVAILABLE SUSPENSION MOUNTING BRACKET. INSTALL COMPLETE WITH MANUFACTURER AVAILABLE SUSPENSION MOUNTING BRACKET. 3.INCLUDE MANUFACTURER AVAILABLE INTEGRAL THERMOSTAT TO PREVENT FREEZING.INCLUDE MANUFACTURER AVAILABLE INTEGRAL THERMOSTAT TO PREVENT FREEZING.
AutoCAD SHX Text
AREA SERVED
AutoCAD SHX Text
MECH ROOM
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
21.WMA.037
AutoCAD SHX Text
TYPE OF HEAT
AutoCAD SHX Text
HEATING
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
COOLING
AutoCAD SHX Text
SUPPLY FAN
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
GENERAL
AutoCAD SHX Text
MARK
AutoCAD SHX Text
SERVING
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
OPERATING WEIGHT, LBS.
AutoCAD SHX Text
LENGTH, WIDTH, HEIGHT
AutoCAD SHX Text
MINIMUM EER
AutoCAD SHX Text
VOLTS/ PH/ HZ
AutoCAD SHX Text
MCA (AMPS)
AutoCAD SHX Text
MOCP (AMPS)
AutoCAD SHX Text
SUPPLY AIR CFM
AutoCAD SHX Text
OUTSIDE AIR CFM
AutoCAD SHX Text
ESP ("W.G.)
AutoCAD SHX Text
FAN RPM
AutoCAD SHX Text
NOMINAL SIZE TONS
AutoCAD SHX Text
TOTAL CAPACITY (MBH)
AutoCAD SHX Text
SENSIBLE CAPACITY (MBH)
AutoCAD SHX Text
OUTSIDE AIR DB/WB, °F.
AutoCAD SHX Text
ENTERING AIR DB/WB, °F.
AutoCAD SHX Text
MOTOR BHP
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
HEATING INPUT (MBH)
AutoCAD SHX Text
HEATING OUTPUT (MBH)
AutoCAD SHX Text
OUTSIDE AIR DB/WB, °F.
AutoCAD SHX Text
LEAVING AIR DB/WB, °F.
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
CARRIER
AutoCAD SHX Text
RTU-1
AutoCAD SHX Text
RTU-2
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
DINING
AutoCAD SHX Text
1-11
AutoCAD SHX Text
1.PROVIDE A FACTORY AVAILABLE UN-INSULATED 14" HIGH FLAT ROOF CURB THAT SHALL BE FIELD PROVIDE A FACTORY AVAILABLE UN-INSULATED 14" HIGH FLAT ROOF CURB THAT SHALL BE FIELD FACTORY AVAILABLE UN-INSULATED 14" HIGH FLAT ROOF CURB THAT SHALL BE FIELD FACTORY AVAILABLE UN-INSULATED 14" HIGH FLAT ROOF CURB THAT SHALL BE FIELD 14" HIGH FLAT ROOF CURB THAT SHALL BE FIELD HIGH FLAT ROOF CURB THAT SHALL BE FIELD ASSEMBLED AND SHIMMED SUCH THAT THE TOP OF THE CURB SETS LEVEL. ROOF CURBS TO BE INSTALLED BY THE GENERAL CONTRACTOR, AND FIELD INSULATED BY THE MECHANICAL CONTRACTOR. 2.PROVIDE WITH LOW AMBIENT CONTROLS, CONDENSER COIL HAIL GUARD, HINGED ACCESS PANELS, PROVIDE WITH LOW AMBIENT CONTROLS, CONDENSER COIL HAIL GUARD, HINGED ACCESS PANELS, CRANK CASE HEATER, AND FROSTAT. 3.SENSORS AND LOW VOLTAGE CONTROL WIRING SHALL BE INSTALLED BY THE MECHANICAL CONTRACTOR. SENSORS AND LOW VOLTAGE CONTROL WIRING SHALL BE INSTALLED BY THE MECHANICAL CONTRACTOR. 4.PROVIDE WITH MANUFACTURER'S REMOTE TEMPERATURE SENSOR AND PROGRAMMABLE 24/7 PROVIDE WITH MANUFACTURER'S REMOTE TEMPERATURE SENSOR AND PROGRAMMABLE 24/7 THERMOSTAT CAPABLE OF AUTOMATIC COOLING/ HEATING CHANGEOVER. 5.PER IECC, PROVIDE ENTHALPY ECONOMIZER SECTION WITH MOTORIZED OUTSIDE AIR DAMPER. PER IECC, PROVIDE ENTHALPY ECONOMIZER SECTION WITH MOTORIZED OUTSIDE AIR DAMPER. 6.PROVIDE FACTORY AVAILABLE RETURN AIR SMOKE DETECTOR(S), CAPABLE OF SHUTTING DOWN THE PROVIDE FACTORY AVAILABLE RETURN AIR SMOKE DETECTOR(S), CAPABLE OF SHUTTING DOWN THE RETURN AIR SMOKE DETECTOR(S), CAPABLE OF SHUTTING DOWN THE AIR SMOKE DETECTOR(S), CAPABLE OF SHUTTING DOWN THE ROOFTOP UNIT UPON ACTIVATION. 7.PROVIDE FACTORY INSTALLED NON-FUSED ELECTRICAL DISCONNECT AND CONVENIENCE RECEPTACLE. PROVIDE FACTORY INSTALLED NON-FUSED ELECTRICAL DISCONNECT AND CONVENIENCE RECEPTACLE. RECEPTACLE SHALL BE FIELD WIRED BY THE E.C. AND POWERED SEPARATELY FROM THE UNIT. 8.PROVIDE BOTTOM ENTRY SINGLE POINT ELECTRICAL POWER CONNECTION. PROVIDE BOTTOM ENTRY SINGLE POINT ELECTRICAL POWER CONNECTION. 9.UNIT SELECTION IS BASED ON R-410A REFRIGERANT AND HIGH EFFICIENCY OPERATION. UNIT SELECTION IS BASED ON R-410A REFRIGERANT AND HIGH EFFICIENCY OPERATION. EFFICIENCY OPERATION. 10.CONTACT MR. JARMALE LEWIS (CARRIER) AT (972)281-6541 FOR PRICING AND VERIFY FINAL CONTACT MR. JARMALE LEWIS (CARRIER) AT (972)281-6541 FOR PRICING AND VERIFY FINAL MR. JARMALE LEWIS (CARRIER) AT (972)281-6541 FOR PRICING AND VERIFY FINAL FOR PRICING AND VERIFY FINAL SELECTIONS FOR EQUIPMENT SELECTION INFORMATION AND ORDERING. 11.PROVIDE UNIT WITH CARRIER HUMIDI-MIZER DEHUMIDIFICATION OPTION AND KELE HC-201 HUMIDISTAT PROVIDE UNIT WITH CARRIER HUMIDI-MIZER DEHUMIDIFICATION OPTION AND KELE HC-201 HUMIDISTAT THAT MOUNTS ON RETURN AIR DUCT.
AutoCAD SHX Text
CARRIER
AutoCAD SHX Text
1-11
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
208/3/60
AutoCAD SHX Text
4000
AutoCAD SHX Text
900
AutoCAD SHX Text
10
AutoCAD SHX Text
80/67
AutoCAD SHX Text
95/75
AutoCAD SHX Text
0.75
AutoCAD SHX Text
2.4
AutoCAD SHX Text
60
AutoCAD SHX Text
GAS
AutoCAD SHX Text
180
AutoCAD SHX Text
148
AutoCAD SHX Text
97.9
AutoCAD SHX Text
21
AutoCAD SHX Text
119.8
AutoCAD SHX Text
92.5
AutoCAD SHX Text
838
AutoCAD SHX Text
54
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
48HCDE11
AutoCAD SHX Text
GAS/ELEC
AutoCAD SHX Text
1099
AutoCAD SHX Text
12.0
AutoCAD SHX Text
89x60x50
AutoCAD SHX Text
208/3/60
AutoCAD SHX Text
5000
AutoCAD SHX Text
1200
AutoCAD SHX Text
12.5
AutoCAD SHX Text
80/67
AutoCAD SHX Text
95/75
AutoCAD SHX Text
0.75
AutoCAD SHX Text
2.9
AutoCAD SHX Text
70
AutoCAD SHX Text
GAS
AutoCAD SHX Text
180
AutoCAD SHX Text
146
AutoCAD SHX Text
89.63
AutoCAD SHX Text
21
AutoCAD SHX Text
151.5
AutoCAD SHX Text
118.5
AutoCAD SHX Text
838
AutoCAD SHX Text
60
AutoCAD SHX Text
48HCEE14
AutoCAD SHX Text
GAS/ELEC
AutoCAD SHX Text
1933
AutoCAD SHX Text
12.2
AutoCAD SHX Text
116x64x58
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
MARK
AutoCAD SHX Text
HEAT INPUT
AutoCAD SHX Text
(MBH)
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
1,2,3,4,5
AutoCAD SHX Text
REZNOR
AutoCAD SHX Text
115 / 1 / 5.1
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
PH-1
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
VOLT / PH / A
AutoCAD SHX Text
AREA SERVED
AutoCAD SHX Text
PATIO
AutoCAD SHX Text
NOTES: :
AutoCAD SHX Text
1.COORDINATE POWER AND DISCONNECT REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. COORDINATE POWER AND DISCONNECT REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 2.INSTALL COMPLETE WITH MANUFACTURER AVAILABLE THERMOSTAT, TRANSFORMER, SUSPENSION MOUNTING BRACKET, FLUE VENT INSTALL COMPLETE WITH MANUFACTURER AVAILABLE THERMOSTAT, TRANSFORMER, SUSPENSION MOUNTING BRACKET, FLUE VENT KIT AND ACCESSORIES FOR AN ENCLOSED PATIO OUTDOOR INSTALLATION. 3.UNIT SHALL BE INSTALLED AT 10'-0"AFF, COMPLETE WITH MANUFACTURER RECOMMENDED CLEARANCES TO COMBUSTIBLES. UNIT SHALL BE INSTALLED AT 10'-0"AFF, COMPLETE WITH MANUFACTURER RECOMMENDED CLEARANCES TO COMBUSTIBLES. 4.HEATER SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. CONNECTIONS SHALL BE MADE BY ELECTRICAL HEATER SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. CONNECTIONS SHALL BE MADE BY ELECTRICAL AND PLUMBING CONTRACTORS. 5.PROVIDE WITH HONEYWELL MODEL #TH411OD1007 DIGITAL, PROGRAMMABLE THERMOSTAT. MECHANICAL CONTRACTOR SHALL PROVIDE WITH HONEYWELL MODEL #TH411OD1007 DIGITAL, PROGRAMMABLE THERMOSTAT. MECHANICAL CONTRACTOR SHALL PROVIDE WITH LOCKABLE COVER AND REMOTE TEMPERATURE SENSOR.
AutoCAD SHX Text
125
AutoCAD SHX Text
UDAS 125
AutoCAD SHX Text
1,2,3,4,5
AutoCAD SHX Text
REZNOR
AutoCAD SHX Text
115 / 1 / 5.1
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
PH-2
AutoCAD SHX Text
PATIO
AutoCAD SHX Text
125
AutoCAD SHX Text
UDAS 125
AutoCAD SHX Text
1,2,3,4,5
AutoCAD SHX Text
REZNOR
AutoCAD SHX Text
115 / 1 / 5.1
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
PH-3
AutoCAD SHX Text
PATIO
AutoCAD SHX Text
125
AutoCAD SHX Text
UDAS 125
AutoCAD SHX Text
1,2,3,4,5
AutoCAD SHX Text
REZNOR
AutoCAD SHX Text
115 / 1 / 5.1
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
PH-4
AutoCAD SHX Text
PATIO
AutoCAD SHX Text
125
AutoCAD SHX Text
UDAS 125
AutoCAD SHX Text
ND-2-PSP-F
AutoCAD SHX Text
ND-2-PSP-F
AutoCAD SHX Text
1
AutoCAD SHX Text
1
Page 5: HAT CREEK BURGERCOMPANY

MECHANICAL

DETAILS

12

UL LISTED GREASE EXHAUST DUCT ACCESS DOOR DETAIL

SCALE: NONE

11

UL LISTED GREASE EXHAUST DUCT WRAP DETAIL

SCALE: NONE

6

SUPPLY DUCT TAKE-OFF DETAIL

SCALE: NONE

5

BRANCH TAKE-OFF FITTING DETAIL

SCALE: NONE

7

CEILING MNTD. RETURN AIR GRILLE DETAIL

SCALE: NONE

9

PIPING AND CONDUIT ROOF PENETRATION DETAIL

SCALE: NONE

10

VERTICAL REFRIGERANT PIPE SUPPORT DETAIL

SCALE: NONE

8

HORIZONTAL REFRIGERANT PIPE SUPPORT DETAIL

SCALE: NONE

15

GAS FIRED UNIT HEATER DETAIL

SCALE: NONE

16

NOT USED

SCALE: NONE

2

KITCHEN UPBLAST GREASE EXHAUST FAN DETAIL

SCALE: NONE

1

ROOFTOP UNIT DETAIL

SCALE: NONE

3

RESTROOM DOWNBLAST EXHAUST FAN DETAIL

SCALE: NONE

4

EXPOSED DUCTWORK LAYOUT SCHEMATIC

SCALE: NONE

13

EXPOSED SUPPLY AIR DUCT DEVICE

SCALE: NONE

14

UNIT HEATER DETAIL

SCALE: NONE

REVISIONDATE

DATE:

SCALE:

DRAWN BY:

SHEET TITLE:

SHEET NUMBER:

REVISIONS

PRO

JEC

T:

07-02-21

STAFF

M3.0

HA

T C

REE

K B

UR

GER

CO

MPA

NY

ATH

ENS,

GEO

RG

IA

AS NOTED

14

901

Q

uo

ru

m D

r. #

565

D

alla

s, T

X 7

52

54

rtm

asso

cia

te

s.com

| 9

72

.3

87

.3

50

0

Sta

te

o

f G

eo

rgia

C

OA

: P

EF

00

68

38

AutoCAD SHX Text
GREASE TRAP
AutoCAD SHX Text
NOTE: INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 96 REQUIREMENTS.
AutoCAD SHX Text
MINIMUM 40" DISCHARGE HEIGHT
AutoCAD SHX Text
RESILIENT GASKET
AutoCAD SHX Text
ROOF ASSEMBLY
AutoCAD SHX Text
18" ABOVE ROOF DECK DUCT SHALL EXTEND MINIMUM
AutoCAD SHX Text
INSTALL COMPLETE WITH (2) EXTERNAL LAYER OF UL LISTED GREASE EXHAUST DUCT WRAP (AS ALLOWED BY THE JURISDICTION HAVING AUTHORITY)
AutoCAD SHX Text
UPBLAST VERTICAL DISCHARGE
AutoCAD SHX Text
U.L. LISTED GREASE EXHAUST FAN
AutoCAD SHX Text
NEMA 3R DISCONNECT FACTORY WIRED TO MOTOR
AutoCAD SHX Text
FIELD WIRING IN LIQUID TIGHT FLEXIBLE CONDUIT (TYPICAL) (ALLOW SUFFICIENT CONDUIT FOR UNIT TO HINGE-UP FULL ROTATION FOR CLEANING.)
AutoCAD SHX Text
VENTILATED ROOFCURB EXTENSION (OR TALL CURB)
AutoCAD SHX Text
FLASH AND COUNTERFLASH ROOF CURB
AutoCAD SHX Text
EXTEND GREASE DUCT UP THROUGH ROOF CURB TO TRANSITION FUNNEL
AutoCAD SHX Text
GREASE EXHAUST DUCT. MINIMUM 16 GAUGE STEEL WELDED LIQUID TIGHT.
AutoCAD SHX Text
PROVIDE FIELD FABRICATED 16 GA. GALVANIZED TRANSITION FUNNEL WITH LIQUID TIGHT SEAMS AND FULLY WELDED MITERED CORNERS
AutoCAD SHX Text
3/8" LAG SCREW 12" ON CENTER, MINIMUM 2 PER SIDE.
AutoCAD SHX Text
PREFABRICATED ROOF 14" HIGH FACTORY CURB
AutoCAD SHX Text
HINGED HOOD FOR SERVICE ACCESS, SHOWN IN THE CLOSED POSITION. INSTALL HINGE ASSEMBLY ON THE FRONT SIDE OF CURB (TOWARD FRONT OF BLDG) TO AVOID ROOF CRICKET
AutoCAD SHX Text
22"
AutoCAD SHX Text
22"
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
RIGID ROUND RETURN AIR DUCT. REFER TO PLAN FOR SIZE
AutoCAD SHX Text
FIELD FABRICATED RETURN PLENUM, CONSTRUCTED OF 24 GA. SHEET METAL AND EXTERNALLY INSULATED
AutoCAD SHX Text
RETURN AIR GRILLE
AutoCAD SHX Text
45%%D
AutoCAD SHX Text
45%%D
AutoCAD SHX Text
EQUAL TO REQ'D BRANCH DUCT DIMENSIONS
AutoCAD SHX Text
SEAL BRANCH TAKEOFF AIR TIGHT
AutoCAD SHX Text
1/4 BRANCH DUCT WIDTH, BUT MIN. 4"
AutoCAD SHX Text
1" MIN. ON TOP AND BOTTOM
AutoCAD SHX Text
EQUAL TO REQ'D BRANCH DUCT DIA.
AutoCAD SHX Text
ADJUSTABLE ELBOW RINGS
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
SUPPLY AIRFLOW
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
1" MIN. ON TOP AND BOTTOM
AutoCAD SHX Text
SUPPLY AIRFLOW
AutoCAD SHX Text
1.LIQUID AND SUCTION LINES MAY BE ROUTED TOGETHER FOR CONVENIENCE, BUT MUST BE COMPLETELY INSULATED FROM LIQUID AND SUCTION LINES MAY BE ROUTED TOGETHER FOR CONVENIENCE, BUT MUST BE COMPLETELY INSULATED FROM EACH OTHER. DO NOT SOLDER LIQUID AND SUCTION LINES TOGETHER. DO NOT ALLOW METAL TO METAL CONTACT. 2.LINES SHOULD BE INSTALLED WITH AS FEW BENDS AS POSSIBLE, ALLOWING SERVICE ACCESS TO THE INDOOR COIL. LINES SHOULD BE INSTALLED WITH AS FEW BENDS AS POSSIBLE, ALLOWING SERVICE ACCESS TO THE INDOOR COIL. 3.USE LONG RADIUS ELBOWS WHEREVER POSSIBLE, EXCEPT IN OIL RETURN TRAPS, WHERE SHORT RADIUS ELBOWS SHOULD USE LONG RADIUS ELBOWS WHEREVER POSSIBLE, EXCEPT IN OIL RETURN TRAPS, WHERE SHORT RADIUS ELBOWS SHOULD BE USED. 4.REFER TO MANUFACTURER'S GUIDELINES FOR THE COMPLETE INSTALLATION.REFER TO MANUFACTURER'S GUIDELINES FOR THE COMPLETE INSTALLATION.
AutoCAD SHX Text
NOTES::
AutoCAD SHX Text
ANGLE IRON OR UNISTRUT SUPPORT. REFER TO STRUCTURAL DRAWINGS FOR METHOD OF SUSPENSION FROM STRUCTURE
AutoCAD SHX Text
HANGER RODS. REFER TO STRUCTURAL DRAWINGS FOR METHOD OF ATTACHMENT TO STRUCTURE
AutoCAD SHX Text
VIBRATION ISOLATORS, WHERE REQUIRED. (TYPICAL)
AutoCAD SHX Text
INSULATION AROUND SUCTION LINE
AutoCAD SHX Text
UNICUSHION PIPE INSULATION SHIELD AS MANUFACTURED BY UNISTRUT
AutoCAD SHX Text
UNISTRUT PIPE CLAMP
AutoCAD SHX Text
REFRIGERANT LIQUID LINE
AutoCAD SHX Text
REFRIGERANT SUCTION LINE
AutoCAD SHX Text
INSULATED SUCTION LINE WITH PIPE SADDLE AND SHIELD
AutoCAD SHX Text
LIQUID LINE
AutoCAD SHX Text
PIPE STRAP
AutoCAD SHX Text
REFER TO ARCHITECTURAL DETAILS FOR DIRECTION ON FABRICATION METHOD
AutoCAD SHX Text
FILL ANNULAR SPACE WITH POURABLE EXPANDING URETHANE FOAM SEALANT (AFTER INSULATING PIPES)
AutoCAD SHX Text
WEATHERPROOF SEALANT
AutoCAD SHX Text
FILL BOTTOM OF ANNULAR SPACE WITH 2" NON SHRINK GROUT
AutoCAD SHX Text
FIELD VERIFY ROOFING SYSTEM
AutoCAD SHX Text
COORDINATE ROUTING OF REFRIGERANT PIPING FROM EQUIPMENT TO ROOF MOUNTED CONDENSING UNIT
AutoCAD SHX Text
ROOF MEMBRANE
AutoCAD SHX Text
FIELD FABRICATED 20 GA. GALVANIZED METAL PITCH PAN
AutoCAD SHX Text
ELECTRICAL POWER CONDUIT
AutoCAD SHX Text
NOTES: 1.GENERAL CONTRACTOR SHALL BE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION INCLUDING PROVIDING THE ROOF PENETRATION, ROOF JACK, FLASHING AND COUNTER-FLASHING FOR A WEATHER TIGHT SEAL. 2.MECHANICAL CONTRACTOR SHALL MECHANICAL CONTRACTOR SHALL INSTALL THE REFRIGERANT PIPING AND INSULATION, AND COORDINATE WORK WITH THE GENERAL CONTRACTOR. 3.ELECTRICAL CONTRACTOR SHALL ELECTRICAL CONTRACTOR SHALL INSTALL THE POWER CONDUIT, AND COORDINATE WORK WITH THE GENERAL CONTRACTOR.
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
ROOFTOP UNIT
AutoCAD SHX Text
CONDENSER COIL
AutoCAD SHX Text
SUPPLY AIR DUCT
AutoCAD SHX Text
ROOF DECK UNDER UNIT TO REMAIN FOR SOUND CONTROL EXCEPT AT DUCT PENETRATION.
AutoCAD SHX Text
GAS SERVICE (WHERE SHOWN ON THE DRAWINGS)
AutoCAD SHX Text
RETURN AIR DUCT
AutoCAD SHX Text
FLEXIBLE DUCT CONNECTION (TYP)
AutoCAD SHX Text
POWER AND CONTROL SERVICES
AutoCAD SHX Text
FACTORY CURB WITH CANT STRIP, COUNTER FLASHING, AND GASKET
AutoCAD SHX Text
VERTICAL (DOWNFLOW) DISCHARGE. FIELD COORDINATE DUCT ROUTING FOR HORIZONTAL DISCHARGE
AutoCAD SHX Text
ELECTRICAL DISCONNECT. DO NOT INSTALL OVER UNIT LABELS OR COILS
AutoCAD SHX Text
ROUTE CONDENSATE DISCHARGE ON ROOF
AutoCAD SHX Text
SHEET METAL RISER FULL SIZE OF FAN OPENING
AutoCAD SHX Text
SUPPORT DUCT RISER WITH ALL THREAD SUPPORT RODS.
AutoCAD SHX Text
FACTORY ROOF CURB TO BE SHIMMED LEVEL. INSTALL PER MANUF. RECOM.
AutoCAD SHX Text
TRANSITION
AutoCAD SHX Text
ROOFTOP EXHAUST FAN
AutoCAD SHX Text
SHEET METAL EXHAUST DUCT RISER. RE: PLANS FOR SIZE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
GRAVITY BACKDRAFT DAMPER
AutoCAD SHX Text
ROOF DECK
AutoCAD SHX Text
NOTE: ACCESS DOORS TO BE LOCATED AT MAXIMUM 10'-0" O.C. AND AT EACH CHANGE IN DIRECTION IN BOTH HORIZONTAL AND VERTICAL DUCT RUNS.
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
10 1/2"
AutoCAD SHX Text
21" TYP
AutoCAD SHX Text
10 1/2"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
1 1/2"
AutoCAD SHX Text
(1) LAYER 3M FIRE BARRIER DUCT WRAP 20A (OR APPROVED EQUAL). PROVIDE (2) LAYERS AS REQUIRED
AutoCAD SHX Text
DOOR OPENING
AutoCAD SHX Text
GREASE DUCT
AutoCAD SHX Text
1/4" ALL THREAD RODS
AutoCAD SHX Text
16 GA. ACCESS COVER
AutoCAD SHX Text
INSULATION PINS
AutoCAD SHX Text
FIRST LAYER 3M FIRE BARRIER DUCT WRAP 20A CUT SAME SIZE AS COVER
AutoCAD SHX Text
ALUMINUM TAPE AT EDGES (TYP)
AutoCAD SHX Text
1/2" WIDE (MIN.) STEEL BANDING AND FILAMENT TAPE (TYP)
AutoCAD SHX Text
GREASE DUCT
AutoCAD SHX Text
3" MIN. LONGITUDINAL OVERLAP
AutoCAD SHX Text
3/8" MIN.HANGER RODS
AutoCAD SHX Text
1/2 x 1/2 x 1/8 SUPPORT ANGLE (WHERE REQUIRED)
AutoCAD SHX Text
NOTE: CONTRACTOR TO INSTALL DUCTWRAP IN STRICT ACCORDANCE TO MANUFACTURER'S REQUIREMENTS
AutoCAD SHX Text
SPEED CLIPS
AutoCAD SHX Text
SPOOL PIECES FOR THREADED RODS
AutoCAD SHX Text
1/4" WING NUTS
AutoCAD SHX Text
SECOND LAYER 3M FIRE BARRIER DUCT WRAP 20A WITH 1" OVERLAP ON ALL SIDES
AutoCAD SHX Text
THIRD LAYER 3M FIRE BARRIER DUCT WRAP 20A WITH ADDITIONAL 1" OVERLAP ON ALL SIDES
AutoCAD SHX Text
T-BAR TYPE/GYP SUSPENDED CEILING
AutoCAD SHX Text
RIGID ROUND DUCT JOINT SCREWED & SEALED
AutoCAD SHX Text
INSULATED SHEETMETAL SUPPLY DUCT. SEALED PER SPECIFICATIONS.
AutoCAD SHX Text
PROVIDE 1" BLANKET INSULATION COVERING AIR DEVICE BACK
AutoCAD SHX Text
SUPPLY AIR DIFFUSER WITH ROUND NECK
AutoCAD SHX Text
FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 5'-0"
AutoCAD SHX Text
NYLON DRAW BAND (TYP)
AutoCAD SHX Text
METAL BAND SUPPORT
AutoCAD SHX Text
TIE OFF TO ROOF STRUCTURE
AutoCAD SHX Text
EXTEND RIGID ROUND SPIRAL SUPPLY DUCT FROM TAP TO AIR DEVICE (SIZED AS NOTED). DUCT TO BE JOINT SCREWED AND SEALED
AutoCAD SHX Text
ROUND SUPPLY AIR DEVICE (SIZED AS NOTED)
AutoCAD SHX Text
SPIN IN TAP WITH BUTTERFLY DAMPER
AutoCAD SHX Text
INTERNAL DUCT LINER
AutoCAD SHX Text
INTERNALLY LINED RIGID ROUND SUPPLY DUCT MAIN. HOLD TIGHT TO BOTTOM OF ROOF JOISTS
AutoCAD SHX Text
INTERNALLY LINED EXPOSED SUPPLY AND RETURN DUCT MAINS FROM ROOF TOP UNIT
AutoCAD SHX Text
1/4" X 1/4" WMS COVERING RETURN AIR OPENING
AutoCAD SHX Text
INTERNALLY LINED EXPOSED SPIRAL DUCT
AutoCAD SHX Text
EXTERNALLY WRAPPED SUPPLY TRUNK ABOVE CONCEALED CEILING SPACE
AutoCAD SHX Text
CONCEALED CEILING SPACE
AutoCAD SHX Text
EXPOSED CEILING
AutoCAD SHX Text
WALL OR PARTITION
AutoCAD SHX Text
UNIT HEATER SHALL BE SECURED TO WALL WITH A MINIMUM OF TWO BRACKETS. BRACKETS PER MANUFACTURERS RECOMMENDATIONS
AutoCAD SHX Text
TWO 5/8" BOLTS, EACH SIDE OF FRAME WITH LOCK WASHERS
AutoCAD SHX Text
5/8" EXPANSION EXPANSION BOLTS (TYP)
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
INTERNALLY INSULATED RECTANGULAR EXPOSED SUPPLY DUCT.
AutoCAD SHX Text
SHEETMETAL OUTLET BOOT SHALL BE FABRICATED SAME SIZE AS AIR DEVICE FRAME. HOLD DEPTH OFF SUPPLY DUCT TO MINIMUM
AutoCAD SHX Text
REFER TO MECHANICAL PLAN FOR REFERENCED AIR DEVICE TYPE
AutoCAD SHX Text
SEAL BOOT CONNECTION AIRTIGHT
AutoCAD SHX Text
INSULATE BOOT WITH 1" DUCTLINER
AutoCAD SHX Text
PROVIDE MANUFACTURER AVAILABLE OPPOSED BLADE DAMPER AIR BALANCING DEVICE
AutoCAD SHX Text
ATTACH DIFFUSER BOOT TO TRUNK DUCT WITH POP RIVETS OR SHEETMETAL SCREWS
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
21.WMA.037
AutoCAD SHX Text
2. ELECTRICAL CONNECTION BY ELEC. CONTRACTOR.
AutoCAD SHX Text
JURISDICTION OVER PROJECT.
AutoCAD SHX Text
OF LOCAL CODE AUTHORITIES HAVING
AutoCAD SHX Text
1. ROOF PENETRATIONS SHALL MEET APPROVAL
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
MIN 3'-0"
AutoCAD SHX Text
JOIST
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
FLUE PIPE
AutoCAD SHX Text
BREIDERT CAP
AutoCAD SHX Text
GAS COCK
AutoCAD SHX Text
DIRT LEG
AutoCAD SHX Text
UNION CONNECTION
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
GAS FIRED
AutoCAD SHX Text
W/ HTR MFG.
AutoCAD SHX Text
VERIFY SIZE
AutoCAD SHX Text
HANGER RODS
AutoCAD SHX Text
G
AutoCAD SHX Text
GAS SUPPLY
AutoCAD SHX Text
SIZE AS SHOWN
AutoCAD SHX Text
ON PLANS.