hawke connectors
TRANSCRIPT
-
7/31/2019 Hawke Connectors
1/28
International
Hazardous Area Connectors
for Global Connection
Solutions
-
7/31/2019 Hawke Connectors
2/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
Connection Solutionswww.ehawke.com
Introduction
A Quality Company
For those who demand quality, reliability and above all, safety,
Hawke International is the obvious choice.
FOR CUSTOMERS WHO DEMAND THE BEST
Smarter products
Worldwide
Product development
First choice
A quality company
Termination service
Hawke International has provided peace of mind to contractors, installers and end users for
over 50 years. Our innovative range of cable connection and termination products,
specifically designed with the customer in mind, have gained worldwide approval and
credibility for the testing conditions of hazardous (classified) locations and hostile
environments.
The customers requirements for sustained safety and reliability under extreme conditions
are therefore Hawke's primary objectives. Furthermore, our superior designs allow ease of
installation, use long life materials and are manufactured to rigorous quality standards. All
this provides the customer with unparalleled benefits of the lowest lifetime cost of purchase.
Located in Manchester, UK, Hawke International has subsidiary locations in Houston, USA and Singapore, along with direct
representation in Brazil, the Middle East, Canada and China. Hawke International is supported worldwide by the Hubbell Group
along with a global network of agents and distributors.
Hawke International recognises that the demands of the customer base never stand still and we are therefore committed to
the ongoing development of our products and features to provide improved safety, versatility, reliability and ease of use.
Hawke International's products are designed and manufactured under a quality system not only complying with ISO 9001 but
also with the latest international standards. Rigorous and regular in-house testing ensures that every product manufactured
meets the highest quality standards expected by the market.
Predominantly used on Offshore and Onshore oil and gas exploration, production and processing facilities. Hawke's products
are the 'First Choice' for the world's major oil, gas and petrochemical companies.
Hawke International has over 50 years of experience in hazardous area connection systems and have a wealth of experienced
staff able to provide assistance in the planning and selection of Ex connectors and related products.
Termination work can be arranged by Hawke International as part of their connection solution, both at our premises in
Manchester or on-site as required. The company have dedicated installation engineers able to offer complete termination
services including cable preparation, marking, gland and connector termination and complete unit testing. This simplifies even
further the use of Hawke connectors as part of your connection requirements.
-
7/31/2019 Hawke Connectors
3/28
International
Hazardous Area ConnectorsforGlobalConnectionSolutions
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
New connector range contents table
1Connection Solutionswww.ehawke.com
Hazardous Area Connector Range
Contents
Colour Code/Page Description
2 Hazardous area connector range - Common features
3
6
Hazardous area connector range - Selection overview
22 Accessories - Short circuit testing, Crimp tool and adaptors/reducers
23
Hazardous area cable glands - 501/421, 501/453/Universal, 501/453/RAC, ICG 653/Universal24
New stainless steel enclosures - EZE box range25
Website technology - Connector selection application, electronic data on CD Rom
4 - 5 Features
16 - 17 Features
10 - 11 Features
7 - 8 - 9 Inserts and Dual crimp - Order code - Dimensions(Technical)
12 -13 - 14 -15Inserts - Order code - Dimensions - Calculations
(Technical)
18 -19 - 20 - 21Inserts - Order code - Dimensions - Calculations
(Technical)
How it works
Instrum
Power
Control
Instrum
Control
Power
Instrum
CONTENTS TABLE
Burullus
BP
Statoil
Egypt
Norway
Norway
Azerbaijan
UK
UK
Power and communication for BUICS and IWOCS controls containers
Connectors used on WOCS Topside electrical surface jumpers
Topside module hook-up
Sub-sea workover station
Used on platform drill head for mobility
Supply electrical signal to a secondary module beside original platform
Statoil
AIOC
Chevron Texaco
Simian/Sienna/Saphire
BP Clair
ACG
Project Name Owner Location Application
Snohvit
Kristin
Captain
UK
Australia
Installed to actuators which control and monitor gas being induced into the turbines
Used on Turret mooring system
Conoco Global Power
Woodside Energy
Conoco Immingham CHP
Enfield RTM
SAMPLE OF MAJOR PROJECT SUCCESSES
-
7/31/2019 Hawke Connectors
4/28
All Hawke ATEX connectors
meet the requirements of
IP66 and IP67 to IEC60529.
They are also deluge
protected to DTS01
offering long term protectionin onerous environments.
The unique mechanical keying system prevents contact damage and ensures safe use by
eliminating the possibility of misconnection of circuits. Machined key and keyway also
ensures connector alignment.
Each pin and socket is fitted
with multilam technology to
ensure reliable low
resistance connection on
each coupling.
Designed and constructed for the most demanding environments, Hawke connectors
are durable in almost any environment, requiring no routine maintenance to ensure
continued performance.
Each connector plug and receptacle can be fitted with an optional mounting flange,
either at point of order or retro fitted as required, allowing easy mounting of the
connectors without the need to disassemble the units.
There are several innovative features common across the range of Hawke connectors. Despite their highly advanced design
and technical features, the range is extremely simple to use and quick to terminate.
HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
2 Connection Solutionswww.ehawke.com
Hazardous Area Connector Range
Common Features
Impossible to
cross mate
Ingress and deluge
protected
High reliability
contacts
Robust design
Retro fit flange option
ATEX
-
7/31/2019 Hawke Connectors
5/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
3
Hazardous Area Connector Range
Selection Overview
Connection Solutionswww.ehawke.com
Connector TypeMinimum Number
of PinsMaximum Number
of PinsMinimum cross sectionalarea of Conductor mm
MaximumConductor mm
MaximumVoltage
MaximumCurrent (amps)
LiveDemate
1
3
1
8
60
4
0.14
0.5
50
2.5
35
630
10
125
780
250V
660VControl
Power
Instrum 9
8
8750V*
SELECTION OVERVIEW
Instrum
Power
Control
This revolutionary design allows the live mate and de-mating of signal and lowpower in hazardous areas safely and quickly. The Instrum connector isavailable with two insert options: the 4-way option will accept cores rangingbetween 0.5mm and 2.5mm and can operate up to a maximum current of 10A(AC1) at 250V AC & 2.5A (DC1) 60V DC. The 8-way option, designed
predominantly for Ethernet applications, will accept cores ranging between0.14mm and 0.37mm and can carry 1A (AC1) at 60V AC & 0.5A (DC1)60V DC.Instrum connectors include an integral Hawke cable gland for easy terminationof both armoured and un-armoured cables.
The Power range of connectors have been designed specifically for theextremely demanding requirements of higher power applications. Inserts areavailable with 1 to 4 contacts with a conductor acceptance range of between50mm and 630mm operating up to 780A and 750V as standard. Othervoltages available on special request. Information on recommended cable glands
for use with the Power connectors can be found on page 24 of this catalogue.
The 3rd generation of Control connectors include many features andrefinements as a result of consumer feedback, which makes them particularlysuitable for control and low/medium power applications. The robust stainlesssteel body can hold up to 60 contacts and will accept conductor sizes rangingbetween 0.5mm and 35mm, operating up to 125A and 660V. Information on
recommended cable glands for use with the Control connectors can befound on page 24 of this catalogue.
Hawke International connectors are ideal for use in gas hazardous areas commonly found in Oil and Gas exploration, productionand process plants. Their features, however, also offer numerous benefits in explosive dust environments as well as harsh andhostile non-explosive applications where temporary but safe disconnection of power is critical.Hawke International's Ex range of connectors permit the safe and rapid service, repair and replacement of key plant, providequick connection to temporary and permament equipment and greatly reduce hook-up time in capital-intensive processes.The Ex range of connectors cover three main application areas: Instrumentation, control and power.For a guide as to which Ex connector may be best suited to an individual application the table below outlines the main variables.
* Other voltages available on special request.
ATEX
-
7/31/2019 Hawke Connectors
6/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the cus tomer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
4 Connection Solutionswww.ehawke.com
Instrum
FeaturesATEXInstrumInstrum
Integral keying
Quick connect thread
Electrical insert
Bulkhead
receptacle (BR)
Anti-rotation
Versatile LSFZH rear seal
Reversible
armour clamp
Connector
plug (CP)
Pre-terminated(Bulkhead) receptacle only
5 Position keyed inserts
Earth continuity clip
Note:
Inline connector - connector plug (CP) and
connector receptacle (CR) also available
-
7/31/2019 Hawke Connectors
7/28
ATEX
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be us ed only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
Profiled Spigot andconnector body preventcable rotation, eliminatingcable damage.
Accommodates a widerange of cable sizes andprovides highly effectivecable grip and ingressprotection.
All BR connectors aresupplied withpre-terminated tails tosuit your requirements.
Machined key and keywayensures connectoralignment.Unique 5 position insertkeying system preventscross-mating.
Secondary keying on theactual insert bodiesguarantees contactalignment, preventing pindamage.
Unique 4 start ACMEthread offers a smooth andquick fully mating action inless than two turns.Earth continuity is achievedvia a 360contact clip.
Easy to assemble electricalinsert allows crimped orsoldered connections.
The Instrum incorporatesHawke's proven and patentedarmour termination method.Two clamping devices aresupplied to accommodatedifferent types of armour orbraid.
5Connection Solutionswww.ehawke.com
Features
Instrum
Anti-rotation
Versatile LSFZH
rear seal Pre-terminated
Reversible armourclamp
Electrical insert
with key
Integral keying Quick connect
Keyed positions
-
7/31/2019 Hawke Connectors
8/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
6 Connection Solutionswww.ehawke.com
How it Works
Instrum
Arc 'quenching' gap.
Exe clearances
between contacts.
Should an ignition occur duringde-mating, it is contained by
the Exd Flamepath.
Once passed the arc quenching
gap, the primary protection
method becomes Exe.Threads still engaged
at this point.
Exe clearances
between contacts.
These diameters are
Exd Flamepaths.
Once de-mated, the protection
method is Exe on the
socket insert IP30 (IP66 - IP67 with cap fitted).
Pin insert cannot remain energised.
Pin and socket inserts are interchangeable
between the CP and BR/CR.
Stage 1
Stage 3
Stage 2
ATEX
The Instrum connectors are designed to provide ease of installation and speed of use whilst providing a flexible, safe and
reliable method for mating and disconnection of circuits which are energised.
flameproof protection concept. The outer
shell of the connector combined with the
integral Hawke cable gland seal ensure thatthe internal connections are protected to the
Exe increased safety protection concept.
When the connector halves are disengaged, the
socket section is protected to IP30 and must
have the protective cap fitted immediately to
restore the full Exe increased safety
requirements and IP rating.
The pins and socket inserts are interchangeable
between all three connector components: i.e.
Bulkhead receptacle, in-line receptacle and
connector plug.
In all installations, the "live" side of the
connector must always contain the
socket insert.
The two mating halves are easily engaged and
disengaged by two full turns of the ACME
custom engaging thread, during which time the
pins and socket are protected by the Exd
During connector engagement anddisengagement any sparking of the contacts
is contained within an arc quenching section
which is housed within the Exd flamepath
areas.
The Instrum
-
7/31/2019 Hawke Connectors
9/28
-
7/31/2019 Hawke Connectors
10/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
8 Connection Solutionswww.ehawke.com
Order Code
Instrum
ATEX
N BR1 BM P 0 4X X AInstrum /
* 4 way Bulkhead Receptacle will always be pre-terminated with 1.5mm conductors, irrespective of cross sectional area.
# Bulkheads also include an additional earth lead.
MATERIAL CODE
CROSS SECTIONAL AREA CODE
BULKHEAD ENTRY THREAD CODE
INSERT TYPE CODE
CONNECTOR STYLE CODE
BULKHEAD RECEPTACLE
CABLE LENGTHCODE
BULKHEAD RECEPTACLE
PIN QUANTITIES #CODE
ARMOUR CLAMP SIZECODE
OUTER SHEATH DIAMETERCODE
CERTIFICATIONCODE
Nickel Plated Brass N
Stainless Steel S
4 x 0.5 - 1mm * A
4 x 1.5 - 2.5mm *8 x 0.14 - 0.37mm
BC
Metric M20 (Standard)
N/A (for CP or CR)
M
NPT " N
X
Pin Insert **
Socket Insert **
P
S
Connector Plug CP
Flanged Connector Plug
Connector Receptacle
Flanged Connector Receptacle
Bulkhead Receptacle (Fixed Pos 1 Std.)
Bulkhead Receptacle (Fixed Pos 2)
Bulkhead Receptacle (Fixed Pos 3)
Bulkhead Receptacle (Fixed Pos 4)
Bulkhead Receptacle (Fixed Pos 5)
FP
CR
FR
BR1
BR2
BR3
BR4
BR5
0.5m (standard)0
1m
2m
3m4m
Customer specified
N/A (for Connector Plug andReceptacle)
1
2
34
C
Customer specifiedC
X
4 (pins 1 - 4 terminated) Std. 4 way*
3 (pins 1, 2 and 3 terminated) 4 way*
8 (pins 1 - 8 terminated) Std. 8 way
4
N/A (for Connector Plug andReceptacle)
3
2 (pins 1 and 3 terminated) 4 way*2
8
X
N/A (Bulkhead Receptacle)
Unarmoured/Copper Braid(will add outer sheath clamp)
U
X
Clamping Ring (2 Rings) 0 - 1.25mmS
N/A (Bulkhead Receptacle)X
Cable Seal (2 Seals) 5.5 - 16mmS
ATEX/IECExA
GOSTG
** Note:- In all installations the "live"side of the connector must alwayscontain the socket insert.
-
7/31/2019 Hawke Connectors
11/28
75.510
20
2
9.5
4 Holes 6.5Equispaced on a
43
M20 = 15
" NPT = 20" NPT = 20
M20
"NPT
"NPT
2
9.5
2
9.5
2
9.5
28-36
27 A/F
8 30
5
5
Optionalmounting flange
for CP & CR
Optionalcable clampfor CP & CR
102-110 112-1281011.5
27 A/F
Connector receptacle
Bulkhead receptacleMounting flange
Connector plug
II 2 G Exde IIC ExtD T85C A21 ATEX
Exde IIC ExtD T85C A21 IECEx
- 40C to + 60C
Baseefa 06 ATEX 0061X
IECEx BAS06. 0018X
Voltage AC 250V
Current AC EN 60947-4-3 10A (AC21)
Current AC EN 60947-4-1 10A (AC1)Current AC EN 60947-4-1 1A (AC3)
Voltage DC 60V
Current DC EN 60947-4-3 2.5A (DC21)
Current DC EN 60947-4-1 2.5A (DC1)
Current DC EN 60947-4-1 0.5A (DC3)
10 amp without thermal protection
IP66, IP67 and DTS01 deluge protected.
On load 150
-50C to +70C
Off load 500
20A gL with thermal protection
Frequency 50/60 Hz
Power Factor 0.9
Note: Caps to be fitted to maintain IP ratings when theconnector halves are separated.
II 2 G Exde IIC ExtD T85C A21 ATEX
Exde IIC ExtD T85C A21 IECEx
- 40C to + 60C
Baseefa 06 ATEX 0061X
IECEx BAS06. 0018X
Voltage AC 60V
Current AC EN 60947-4-3 1A (AC21)
Current AC EN 60947-4-1 1A (AC1)Current AC EN 60947-4-1 0.1A (AC3)
Voltage DC 60V
Current DC EN 60947-4-3 0.5A (DC21)
Current DC EN 60947-4-1 0.5A (DC1)
Current DC EN 60947-4-1 0.1A (DC3)
2 amp without thermal protection
IP66, IP67 and DTS01 deluge protected.
On load 150
-50C to +70C
Off load 500
5A gL with thermal protection
Frequency 50/60 Hz
Power Factor 0.9
Note: Caps to be fitted to maintain IP ratings when theconnector halves are separated.
Explosion Protection
Ambient Temperature
Ratings 4 Way
Maximum No. of make &
break operations (EN61984)
Fuse Rating 4 Way
IP Rating
Storage Temperature
Certification
Explosion Protection
Ambient Temperature
Ratings 8 Way
Maximum No. of make &
break operations (EN61984)
Fuse Rating 8 Way
IP Rating
Storage Temperature
Certification
HWK51 August '08
International
To the best of our knowledge the information contained in t his leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
9
Dimensions
Technical Data
Connection Solutionswww.ehawke.com
Instrum
ATEX
-
7/31/2019 Hawke Connectors
12/28
-
7/31/2019 Hawke Connectors
13/28
ATEX
To the best of our knowledge the information contained in this leaflet,
is accurate at the time of going to print and the company reserves the
right to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors or
omissions that may exist. It is the customer's responsibility to ensure
that the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyright
therein is the property of: Hawke International a trading name of Hubbell Ltd
(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for which
it is provided and no reproduction or publication of the document may be made
and no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
Provides an extended
installation keyway, which
assists connector assembly
by making pin/socket
insertion quick and easy.
Improves accessibility for
soldering/crimping
conductors, as the spacer
tube is retrofitted once
electrical termination is
complete.
Provides direct inspection
of the flameproof seal and
offers users the peace of
mind that the connector
is safe for installation.
The threaded bulkhead
connector utilises industry
standard threads and also
incorporates an integral
'o' ring seal.
Pin and socket inserts are
numbered front and back
to assist wiring and avoid
termination errors.
Crimp and solder inserts
available.
Unique ACME thread offers
a smooth and quick fully
mating action.
Allows the connector to
be installed onto a
pre-assembled cable
gland.
The unique visual 5 position
insert keying system
(3 on Ex16) along with the
integral machined keyways
prevent contact damage and
ensures safe use by
eliminating the possibility
of misconnection of adjacent
circuits.
11Connection Solutionswww.ehawke.com
Control
Features
Easy fieldwireable Keyway tube
Keying positionKeying position
Running couplerAcme thread atmating interface
Spacer tubeSpacer tube
Fully inspectable
flameproof barrier Threaded bulkhead
-
7/31/2019 Hawke Connectors
14/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves the
right to improve or modify any product illustrated without notification.
The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensure
that the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd
(A member of the Hubbell Inc Group of Companies).
Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be made
and no article may be manufactured or assembled in accordance with information
contained in the document without prior written consent of the owner.
12 Connection Solutionswww.ehawke.com
Control
InsertsATEX
All Hawke Contr connectors have a maximum working voltage of 660V DC (660V AC) as standard.Other voltages avilable on special request.
INSERT SELECTION TABLE
TABLE
Note: Inserts for use in bulkhead receptacles are solder termination only for contact sizes of 6mm and above.
Shell Size 16 Shell Size 25 Shell Size 32 Shell Size 40 Shell Size 50 Shell Size 63
Configuration
10 x 2.5mm + Earth 19 x 2.5mm + Earth 37 x 2.5mm + Earth
12 x 2.5mm + Earth 4 x 25mm + Earth
4 x 35mm + Earth
4 x 1.5mm + Earth 12 x 1.5mm + Earth
9 x 1.5mm + Earth12 x 1.5mm + Earth
4 x 2.5mm + Earth
7 x 2.5mm + Earth
4 x 6mm + Earth
4 x 6mm + Earth
6 x 6mm + Earth
3 x 10mm + Earth
4 x 10mm + Earth
3 x 16mm + Earth
4 x 16mm + Earth
19 x 1.5mm + Earth
3 x 1.5mm + Earth
4 x 1.5mm + Earth
24 x 1.5mm + Earth 37 x 1.5mm + Earth 49 x 1.5mm + Earth
30 x 1.5mm + Earth 27 x 2.5mm + Earth 60 x 1.5mm + Earth
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Insert
Size
Internal Diameter of cup (mm)Nominal
Soldered Crimped
1.5mm
2.5mm
6mm
10mm
16mm
25mm
35mm
3
2
3.5
7
7
8
8
3
2
3.2
4
5
6.5
8.3
Ex16-3 x 1.5 Ex25-4 x 1.5Ex16-4 x 1.5
Ex32-12 x 1.5 Ex32-19 x 1.5 Ex32-10 x 2.5
Ex32-6 x 6 Ex32-3 x 10 Ex32-4 x 10 Ex32-3 x 16 Ex32-4 x 16
Ex40-24 x 1.5 Ex40-30 x 1.5 Ex40-19 x 2.5 Ex40-4 x 25 Ex40-4 x 35
Ex50-37 x 1.5 Ex50-27 x 2.5 Ex50-37 x 2.5 Ex63-49 x 1.5 Ex63-60 x 1.5
Ex25-9 x 1.5 Ex25-12 x 1.5 Ex25-4 x 2.5
Ex32-12 x 2.5 Ex32-4 x 6
Ex25-7 x 2.5 Ex25-4 x 6
-
7/31/2019 Hawke Connectors
15/28
ATEX
To the best of our knowledge the information contained in this leaflet,
is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.
The company is unable to accept liability for any inaccuracies, errors or
omissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyright
therein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).
Copyright Condition: This document shall be used only for the purpose for which
it is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with information
contained in the document without prior written consent of the owner.HWK51 August '08
International
* Note:
Inserts for use in bulkhead receptacles are soldertermination only for contact sizes of 6mm and above.
Hawke International does not recommend the use oftheir ControlEx Connectors in applications where rigidPVC/SWA/PVC power cabling (typically to BS 6346standards) is used in portable/semi-portable applications.
13Connection Solutionswww.ehawke.com
Control
Order Code
S CP 19V 1.5 SSExd 32 x FLFPC AControl /
PROTECTION CODE
KEYING SYSTEM CODE
CONNECTOR STYLE CODE
CODE
TERMINATION STYLECODE
MATERIAL CODE
CONTACT TYPE
CONTACT TYPE
CODE
ACCESSORIESCODE
CERTIFICATIONCODE
NUMBER OF CONTACTS
CODE
SHELL SIZE CODE
Flameproof Exd
16
25
32
40
50
63
16
25
32
40
50
63
Fixed Keying F
Variable Keying V
Connector Plug CP
Connector Receptacle
Bulkhead Receptacle
CR
BR
ATEX/IECEx
GOST
A
G
Brass B
Stainless Steel (as standard) S
Solder *
Crimp *
No Insert
S
C
X
1.5 1.5 mm
2.5 mm
4 mm
6 mm
10 mm
16 mm
25 mm
35 mm
2.5
4
6
10
16
25
35
Pin
Socket
No Insert
P
S
X
No InsertX
FL Mounting Flange
Flameproof Plug Cap
Flameproof Receptacle Cap
Environmental Plug Cap
Environmental Receptacle Cap
FPC
FRC
PPC
PRC
See Insert Selection Chart
No InsertX
-
7/31/2019 Hawke Connectors
16/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,
is accurate at the time of going to print and the company reserves the
right to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors or
omissions that may exist. It is the customer's responsibility to ensure
that the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyright
therein is the property of: Hawke International a trading name of Hubbell Ltd
(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for which
it is provided and no reproduction or publication of the document may be made
and no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
14 Connection Solutionswww.ehawke.com
Control
DimensionsATEX
Connector plug Connector receptacle
Flameproof receptacle cap
The receptacle cap andplug cap are available inacetal and provide anIP rating of IP66/67. Theymay only be used when thesocket or plug is notre-energised followingdisconnection.
The flameproof cap must befitted to the connector beforethe power is restored to thedisconnected circuit.
For connector plugs and connector receptacles cable glands arerequired to terminate incoming cables. These can be selectedfrom our cable gland catalogue or our website.These glands include but are not restricted to 501/453/Universaland the ICG 653/Universal. See page 24. For portable application
ICG 653/Universal Cable Gland
Bulkhead receptacle
Flameproof plug cap
Hawke recommend the ICG 653/Universal cable gland.
*Bulkhead entry thread L can be adapted to other sizes. This may affect the overall length of unit. Contact Hawke International for details.**Thread entry V can be adapted to suit smaller sizes on request. Contact Hawke International for details.
Dimension Ex16 Ex25 Ex32 Ex40 Ex50 Ex63
A
B
G
U
H
M
R
S
N A/F
(1.5mm Pitch)
E
115
92
33
35
37
119
32
M25
M16
54
55
36
24
36
59
29
15
143
120
41
35
49
146
45
M32
M25
54
65
46
38
36
59
41
15
145
122
46
35
57
149
51
M40
M32
56
72
55
42
36
59
47
15
145
122
59
35
65
149
59
M50
M40
56
82
65
52
36
59
55
15
143
120
66
35
76
146
70
M63
M50
56
92
80
64
36
59
67
15
143
120
83
35
90
146
83
M75
M63
56
108
95
76
36
59
79
15
11 11 11 11 11 11
C
D
F
W
45 60 62 62 60 60X
P
T
*Thread L
(1.5mm Pitch)**Thread V
HAWKE Ex SERIES DIMENSIONS (MM)
C
D
W
B
A
mating face
Gland entrythread V
Optional
mounting
flange.
Details on
request.
External earth
X 12
F
C
E
X12
External earth
W
Gland entry
thread V
F
NA/F
M G H
ThreadL
F
T
U
P
D
S
R
mating face
-
7/31/2019 Hawke Connectors
17/28
ATEX
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves the
right to improve or modify any product illustrated without notification.
The company is unable to accept liability for any inaccuracies, errors or
omissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd
(A member of the Hubbell Inc Group of Companies).
Copyright Condition: This document shall be u sed only for the p urpose for which
it is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with information
contained in the document without prior written consent of the owner.HWK51 August '08
International
W = Dissipated wattage factor of the connector
N = The number of conductors to be terminated/number of contacts required. (Note: A contact comprises of a pin and socket).
I = The current requirement per contact.(Note: This must be equal to or less than the maximum current rating of the contact, as shown in table 2).
R = The combined cable and contact resistance (see table 2).
Values pertinent to these definitions must then be input into the following equation to calculate the dissipated wattage (W) of yourchosen arrangement:
W = N x I x R(Note: The results must be lower than the maximum figure shown in table 1 for the appropriate temperature class and ambienttemperature).e.g. T6 40C ambient application with 9 x 1.5mm conductors, running at 7 amps.
N = 9 contacts I = 7 amps R = 0.0166 (1.5mm soldered combined cable and contact resistance)
Therefore an Ex25 Connector should be specified for this application as the shell size can accommodate the required 9 x 1.5mmpin/socket inserts (see page 12 - Inser t Selection Table) and the r esultant dissipated wattage (7.32 watts) is below the maximumpermitted 8 watts (see table 1).
This equation can also be transposed to facilitate the calculation of the maximum number of conductors permitted in your selectedconnector 1 and the maximum allowable current within the upper ambient temperature of your location 2
(Note: The result of equation must not exceed the maximum current rating of the contacts (see table 2).
1 N = WR x I
W
N x R
2
2 I =
Note: Unless otherwise requested, connectors will be marked as T5 with an upper ambient temperature of +40C.
Other ambient temperature options can be extrapolated fromtable 1 above, or contact Hawke International for more information.
To select the shell size of the connector, it is essential that you calculate the dissipated wattage of the
arrangement. This ensures that the arrangement does not exceed the maximum permitted temperatureclassification with regard to the upper ambient temperature for the area of installation. (please refer totable 1 for the maximum allowable dissipated wattage per connector size).
15Connection Solutionswww.ehawke.com
Control
Calculations
Dissipated wattage calculation
Therefore W = 9 x 49 x 0.0166 = 7.32 watts.
Equation definitions
TABLE 1 TABLE 2
Connector SizeTemperature Class
T6 T5 T6 T5
Upper AmbientTemperature of +40C
Temperature Class
Upper AmbientTemperature of +50C
T6 T5Temperature Class
Upper AmbientTemperature of +60C
5W
8W
10.5W
12W
13W
17W
7W
11W
17W
20W
29W
4W
6W
8W
9W
10W
13W
6W
10W
12W
14W
17W
24W
2.6W
4W
5.4W
5.9W
6.5W
8.5W
4.6W
7W
9W
10.5W
12.5W
17W
Ex16
Ex25
Ex32
Ex40
Ex50
Ex63
Maximum allowable dissipated wattage
ContactSize
Combined Cable andContact Resistance (Ohms)
Soldered Crimped
ContactCurrentRating
1.5mm
2.5mm
6mm
10mm16mm
25mm
35mm
10 amps
17 amps
30 amps
78 amps78 amps
125 amps
125 amps
0.0166
0.0173
0.0109
0.0054
0.00330.0024
0.0018
0.0015
0.0102
0.0027
0.0047
0.0018
0.0012
0.0009
14.5W
-
7/31/2019 Hawke Connectors
18/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
16 Connection Solutionswww.ehawke.com
Power
FeaturesATEX
PowerPower
Metal keyway
Variable keying position
Multilam contact technology
Internal earth
External Earth
Running coupler
Acme thread at
mating interface
Crimp/solder
cable connection
Connector
receptacle-CR
Connector plug-CP
-
7/31/2019 Hawke Connectors
19/28
ATEX
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading n ame of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
Allows the connector to
be installed onto a
pre-assembled cable
gland.
The unique visual 5 position insert keying system along with the integral machined
keyway prevents contact damage and ensures safe use by eliminating the possibility of
misconnection of adjacent circuits.
Unique ACME thread offers
a smooth and quick fully
mating action.
Internal earth fitted as
standard. Sized to suit
cables earthing facility.
Tried and tested multiple high contact force, low resistance multilams used in all moving
contacts.
Insert assembled outside
connector shell to assist
wiring and allow greater
flexibility.
17Connection Solutionswww.ehawke.com
Power
Features
Acme thread at
mating interface
Running coupler Easy fieldwireable
Keying position
Internal earth
Multilam technology
-
7/31/2019 Hawke Connectors
20/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
18 Connection Solutionswww.ehawke.com
Power
InsertsATEX
All Hawke connectors have a maximum working voltage of (750V AC).Other voltages and contact configurations also available.
Power
INSERT SELECTION TABLE
Shell Size 32 Shell Size 40 Shell Size 50 Shell Size 63 Shell Size 75
Configuration
4 x 50mm + Earth 3 x 150mm + Earth
4 x 70mm + Earth
1 x 185mm + Earth 3 x 50mm + Earth
1 x 240mm + Earth
1 x 185mm + Earth
1 x 240mm + Earth
3 x 70mm + Earth
1 x 50mm + Earth
1 x 70mm + Earth
1 x 95mm + Earth
1 x 120mm + Earth
1 x 150mm + Earth
3 x 95mm + Earth 3 x 185mm + Earth
3 x 120mm + Earth
4 x 120mm + Earth
4 x 95mm + Earth
1 x 300mm + Earth
1 x 400mm + Earth
4 x 150mm + Earth
3 x 240mm + Earth
4 x 185mm + Earth
4 x 240mm + Earth
1 x 500mm + Earth
1 x 630mm + Earth-
-
-
-
-
-
-
-
-
-
-
-
-
Ex32-1 x 50 Ex32-1 x 70 Ex32-1 x 95 Ex32-1 x 120
Ex50-3 x 50 Ex50-3 x 70 Ex50-4 x 50 Ex50-4 x 70 Ex50-1 x 185 Ex50-1 x 240
Ex63-3 x 95 Ex63-3 x 120 Ex63-3 x 150
Ex75-4 x 185
Ex63-4 x 95
Ex63-4 x 120 Ex63-4 x 150 Ex63-1 x 400Ex63-1 x 300 Ex75-3 x 185
Ex75-3 x 240 Ex75-4 x 240 Ex75-1 x 500 Ex75-1 x 630
Ex32-1 x 150 Ex40-1 x 185 Ex40-1 x 240
-
7/31/2019 Hawke Connectors
21/28
ATEX
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
** Contact Hawke International if conductor is larger than that stated.
* Note:
Only the connector receptacle (CR) can beflange mounted.
19Connection Solutionswww.ehawke.com
Power
Order Code
Exd 32 CPB 4 50A S AFLFPCPower /
PROTECTION CODE
CONNECTOR STYLE CODE CONTACT TYPE MAXIMUM CONDUCTORACCEPTANCE DIAMETER (mm)**CODE
MATERIAL CODE
CONTACT TYPECODE
ACCESSORIESCODE
CERTIFICATIONCODE
NUMBER OF CONTACTSCODE
SHELL SIZE CODE
INTERNAL EARTH SIZE CODE
Flameproof Exd
32
40
50
63
75
32
40
50
63
75
Connector Plug CP
Connector Receptacle CR
ATEX/IECExA
GOSTG
Brass
B
Stainless Steel (as standard)
Nickel Plated Brass
Note: (for single core cables,Brass must be used)
Note: (should be at least 50%of phase conductor size)
S
N
50 50mm
70mm
95mm
120mm
150mm
185mm
240mm
300mm
400mm
500mm
630mm
70
95
120
150
185
240
A50mm
70mm
95mm
120mm
150mm
185mm
240mm
B
C
D
E
F
G
300
Pin
Socket
P
S
9.5
11.5
13.0
14.5
16.5
18.5
20.5
25.0
29.0
32.0
38.0
400
500
630
FL Mounting Flange *
Flameproof Plug Cap
Flameproof Receptacle Cap
Environmental Plug Cap
Environmental Receptacle Cap
FPC
FRC
PPC
PRC
See Insert Selection Chart
No InsertX
-
7/31/2019 Hawke Connectors
22/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
20 Connection Solutionswww.ehawke.com
Power
DimensionsATEX
Connector plug Connector receptacle
Flameproof receptacle cap
The receptacle cap and
plug cap are available in
Acetal and provide an
IP rating of IP66/67. They
may only be used when the
socket or plug is not
re-energised following
disconnection.
Flameproof plug cap
The flameproof cap must be
fitted to the connector before
the power is restored to the
disconnected circuit.
For connector plugs and connector receptacles cable glands arerequired to terminate incoming cables. These can be selectedfrom our cable gland catalogue or our website.These glands include but are not restricted to 501/453/Universaland the ICG 653/Universal. See page 24. For portable application
Hawke recommend the ICG 653/Universal cable gland.
ICG 653/Universal Cable Gland
Dimension Ex32P Ex40P Ex50P Ex75P
A
B
U
R
S
Thread V (1.5mm Pitch)
E
228
168
60
68.5
73
251
67
M32*
100
48
60
75.5
61
228
168
66
68.5
79
251
73
M40*
106
55
60
75.5
68
228
168
76
68.5
89
251
82.5
M50*
116
65
60
75.5
77
238
178
101
68.5
114
261
108
M75*
141
90
60
76
102
C
D
F
W
184 184 184 194
Ex63P
228
168
89
68.5
102
251
95
M63*
129
78
60
75.5
90
184X
P
T
*Other entry threads also available.
HAWKE Ex SERIES DIMENSIONS (MM)
C
D
B
A
mating face
Gland entry
thread V
Optional
mounting
flange.
Details on
request
External earth
F
C
E
16
X
External earth
W
Gland entry
thread V
F
T
U
P
D
S
R mating face
-
7/31/2019 Hawke Connectors
23/28
ATEX
To the best of our knowledge the information contained in t his leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
W = Dissipated wattage factor of the connector
N = The number of conductors to be terminated/number of contacts required. (Note: A contact comprises of a pin and socket).
I = The current requirement per contact.(Note: This must be equal to or less than the maximum current rating of the contact, as shown in table 2).
R = The combined cable and contact resistance (see table 2).
Values pertinent to these definitions must then be input into the following equation to calculate the dissipated wattage (W) of yourchosen arrangement:
W = N x I x R(Note: The results must be lower than the maximum figure shown in table 1 for the appropriate temperature class and ambienttemperature).e.g. T6 40C ambient application with 4 x 95mm conductors, each running at 160 amps.
N = 4 contacts I = 160 amps R = 0.000283 (95mm combined cable and contact resistance)
Therefore an Ex63P Connector should be specified for this application as the shell size can accommodate the required 4 x 95mmpin/socket inserts (see page 18 - Insert Selection Table) and the resultant dissipated wattage (28.9 watts) is below the maximumpermitted 30.2 watts (see table 1).
This equation can also be transposed to facilitate the calculation of the maximum number of conductors permitted in your selectedconnector 1 and the maximum allowable current within the upper ambient temperature of your location 2
(Note: The result of equation must not exceed the maximum current rating of the contacts (see table 2).
1 N = WR x I
W
N x R
2
2 I =
Note: Unless otherwise requested, connectors will be marked as T5 with an upper ambient temperature of +40C.
Other ambient temperature options canbe extrapolated from table 1 above, or contactHawke International for more information.
To select the shell size of the connector, it is essential that you calculate the dissipated wattage of the
arrangement. This ensures that the arrangement does not exceed the maximum permitted temperatureclassification with regard to the upper ambient temperature for the area of installation. (please refer totable 1 for the maximum allowable dissipated wattage per connector size).
21Connection Solutionswww.ehawke.com
Power
Calculations
Dissipated wattage calculation
Therefore W = 4 x 25600 x 0.000283 = 28.9 watts.
Equation definitions
TABLE 1 TABLE 2
Connector SizeTemperature ClassT6 T5 T6 T5
Upper AmbientTemperature of +40C
Temperature Class
Upper AmbientTemperature of +50C
T6 T5Temperature Class
Upper AmbientTemperature of +65C
20.5W
22.5W
25.8W
30.2W
36.3W
27.5W
35.3W
41.5W
49.5W
15.75W
17.5W
20W
23.5W
28.25W
26W
28W
32.25W
37.7W
45.25W
7.5W
8.7W
10W
11.7W
14W
15.75W
17.5W
20W
23.5W
28.25W
Ex32P
Ex40P
Ex50P
Ex63P
Ex75P
Maximum allowable dissipated wattage
ContactSize
ContactCurrentRating
50mm
70mm
95mm120mm
150mm
185mm
240mm
300mm
400mm
500mm
630mm
190amps
240amps
290amps340amps
385amps
440amps
520amps
590amps
670amps
720amps
780amps
514
387
283239
202
170
144
82
67
54
45
30.5W
CombinedCable andContact
Resistance(Ohms)
-
7/31/2019 Hawke Connectors
24/28
-
7/31/2019 Hawke Connectors
25/28
International
Hazardous Area Connectors
for Global ConnectionSolutions
ATEX
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
Our website has now been updated to include the NEW Members
Area. This area is all about solving problems and getting quick access
to relevant Hawke product information.
This has been designed to provide on line assistance when selecting
and installing our products, utilising our new state of the art selection
software.
Within our members area you will have access to:
Frequently asked questions section (FAQ's).
Cable gland selection application.
Cable gland installation training videos.
Connector selection application.
Hawke catalogue downloads (PDF format).
State of the art, rich internet application for rapid and easy selection of connectors. All wattage calculations etc. are
worked out for you. All that is required is for the user to input the cable details.
Projects can be saved and edited. Completed projects can be sent to Hawke International for quoting purposes.
Shell and insert size
selection.
Accessories and keying
system selection.
Cable gland plus adaptor
and reducer selection.
This screen displays the
connector, gland and any
adaptors/reducers
required.
CD RomHazardous Area Connectors for Global Connection Solutions catalogue
in PDF format.
The Instrum , Control and Power connector presentation.
Paper catalogueInformation on the NEW Instrum , Control and Power connectors.
Connector accessories - adaptors, reducers, crimp tool and insert tool.
Brief description of connector selection application.
Cable glands.
Eze stainless steel enclosures.
23Connection Solutionswww.ehawke.com
State of the Art - Website Technology
www.ehawke.com
Connector selection application
Electronic data on CD Rom
Step 1 Step 2 Step 3 Step 4
-
7/31/2019 Hawke Connectors
26/28HWK51 August '08
International
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
24 Connection Solutionswww.ehawke.com
Hazardous Area Cable Glands
Cable Glands
501/421
501/453/Universal
501/453/RAC
ICG 653/Universal
ATEX
The 501/453/Universal cable gland provides a flameproof seal on the
inner cable sheath and an IP seal on the outer sheath. It utilises
reversible armour clamp (RAC) technology and can therefore
accommodate all types of armoured or braided cables (W, X and Z).
The cable gland is particularly suitable for use on 'soft' inner cable
sheaths that exhibit "Cold Flow" characteristics as the inner diaphragm
seal will not damage the cable bedding.
The cable gland is dual certified Exd and Exe and is suitable for
installation in Zone 1 (21) and Zone 2 (22) hazardous areas.
The 501/453/RAC cable gland provides a flameproof seal on the inner
cable sheath and an IP seal on the outer sheath. It utilises reversible
armour clamp (RAC) technology and can therefore accommodate all
types of armoured or braided cables (W, X and Z).
The cable gland is dual certified Exd and Exe and is suitable for
installation in Zone 1 (21) and Zone 2 (22) hazardous areas.
The ICG 653/Universal cable gland provides a flameproof barrier seal on
the individual insulated cable cores and prevents entry of the products
of an explosion into the cable's surrounding environment. It also
provides an IP seal on the cable outer sheath. The cable gland is suitable
for cables that are not effectively filled and for cables with a 'soft' inner
sheath that exhibit "Cold Flow" characteristics. The cable gland is dual
certified Exd and Exe and is suitable for installations in Zone 1 (21)
and Zone 2 (22) hazardous areas, where the enclosure is greater than
2 litres in volume and contains an ignition source and requires IICapparatus.
The 501/421 cable gland provides a seal on the outer cable sheath and
is intended for use on non-armoured elastomer and plastic insulated
cables. The cable gland is dual certified Exd and Exe and is suitable
for installation in Zone 1 (21) and Zone 2 (22) hazardous areas.
'
B'
'
A'
EntryThread
'G' Approx (Compressed Length)'H'
Metric
Entry
Deluge
Boot
Diaphragm
SealArmour/Braid
'C'
Armour/Braid'C'
'
A'
EntryThread
'G' Approx (Compressed Length)
MetricEntry
'
B'
'H'
'G' Approx (Compressed Length)'H'
MetricEntry
DelugeBoot
'
B'
Armour/Braid'C'
'
D'
EntryThread
'
E'
InspectableCompound
'G' Approx(Compressed Length)'H'
MetricEntry
'
B'
EntryThread
-
7/31/2019 Hawke Connectors
27/28
ATEX
To the best of our knowledge the information contained in this leaflet,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be us ed only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.HWK51 August '08
International
Hawke International is renowned for the development of easy to installand inspect, innovative hazardous area products. To add to it's existingproduct portfolio, Hawke has introduced the unique EZE range ofstainless steel Exe ATEX certified terminal boxes. This product isavailable in three sizes, the EZE 22, EZE 42 and the EZE 62.
Reliability and quality
These products are manufactured to the highest quality levels from themost suitable materials to provide the same long term reliabilitynormally associated with Hawke International products in safety criticalharsh and hazardous, oil, gas and petrochemical environments.
This new range is a result of consultations with customers to determine whatthey require from electrical equipment to reduce the installation and inspectiontimes and to make the installation work easier to perform. This consultationproved to be of particular importance as our customers terminal box installationpractices have changed over the years with revised emphasis on base entry cablingfor terminal boxes. This detail has been considered carefully and implemented into
the new EZE range of enclosures.
Three enclosure sizes.Exe II T5 or T6/ II 2 GD BASEEFA ATEX certified.-40C to +80C ambient temperature range.Electro-polished grade 316 stainless steel.High and low temperature silicone gaskets.IP66 and BASEEFA witnessed DTS01 deluge tested.
Unique flip top lid.Lid prop holds lid up during installation.Lid can be used as a weather shield during installation or removed toassist wiring.Unequalled front and side access for wiring and inspection.50% reduction in installation time.Designed specifically for base cable entries.Easily removable, raised terminal rails.One size modular gland plate fits all boxes.Quick release gland plate has two easily accessible fixing screws.Padlockable lid feature.Captive lid and gland plate fixing screws.
Available as a component approved empty enclosure.
25Connection Solutionswww.ehawke.com
New Stainless Steel Enclosures
EZE Box Range
Commitment to customers
Installation made easy
-
7/31/2019 Hawke Connectors
28/28
Singapore Office
Hawke International
130 Joo Seng Road#03 02
USA Office
Hawke International4140 World Houston Parkway
S it 130
UK Office
Hawke InternationalOxford Street West,
A h U d L
To the best of our knowledge the information contained in this brochure,is accurate at the time of going to print and the company reserves theright to improve or modify any product illustrated without notification.The company is unable to accept liability for any inaccuracies, errors oromissions that may exist. It is the customer's responsibility to ensurethat the product is suitable for their application.
All copyright reserved-Hubbell Ltd 2008. This document and all copyrighttherein is the property of: Hawke International a trading name of Hubbell Ltd(A member of the Hubbell Inc Group of Companies).Copyright Condition: This document shall be used only for the purpose for whichit is provided and no reproduction or publication of the document may be madeand no article may be manufactured or assembled in accordance with informationcontained in the document without prior written consent of the owner.
Agent/Distributor
International
www.ehawke.com
Connection Solutionsh k