hazardous waste storage - flammable storage - chemical storage | denios, inc., | u.s. division

39
The environment‘s partner Chemical Storage Cabinets Chemical Storage Buildings Customized Enclosures – Temperature Controlled and Fire Rated Designs Chemical Storage Lockers Steel Spill Decking Systems Automatic Doorway Spill Barriers Large Capacity Containment Berms – The HazBerm Chemical Storage and Hazardous Process Containment Technology

Upload: denios-inc-us-division

Post on 19-Jan-2015

307 views

Category:

Business


13 download

DESCRIPTION

For over 20 years DENIOS has been the worldwide leader in the design and manufacture of custom engineered chemical storage structures. Working directly with our customers we help assess risks and provide solutions for the safe storage and containment of hazardous chemicals and processes.

TRANSCRIPT

Page 1: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

1 1The env i ronment ‘s par tner

Chemical Storage Cabinets

Chemical Storage Buildings

Customized Enclosures – Temperature Control led and Fire Rated Designs

Chemical Storage Lockers

Steel Spil l Decking Systems

Automatic Doorway Spil l Barriers

Large Capacity Containment Berms – The HazBerm

Chemical Storage and Hazardous Process Containment Technology

Page 2: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

32

For over 20 years DENIOS has been the worldwide leader in the design and manufacture of custom engineered chemical storage structures. Working directly with our customers we help assess risks and provide solutions for the safe storage and containment of hazardous chemicals and processes.

DENIOS ENGINEERING provides you

A complete understanding of hazardous chemicals and chemical processes. Our Technical Sales and Engineering Staff know specific chemicals and the risks they pose to facilities, personnel, and the environment. They will work with you every step of the way in designing a safe storage solution for your individual applications.

Expertise in helping you meet applicable laws and regulations. DENIOS not only knows the regulations, we work directly with leading insurers, risk managers, and government authorities in developing new equipment or setting performance standards for existing designs and construction. We will work with you in meeting Federal standards as well as those of your local authorities, helping make sure your DENIOS products are in complete compliance.

When we put a DENIOS label on your product it’s to let you know we stand behind what we design and manufacture, and that we’re here for you well after the sale is completed.

DENIOS,

your partner

in safety and

environmental

protection

Introduction4 Overview – Codes and Regulations Governing the Storage

of Hazardous Chemicals and Processes

DENIOS Storage Cabinets6 Introduction to Chemical Storage Cabinets

8 FM Approved Storage Cabinets

9 FM Approved Storage Cabinets – Drums

10 FM Approved Storage Cabinets – IBC Totes

11 FM Approved Storage Cabinets – 2-Hour Fire Rated

12 Storage Cabinets – IBC Totes

16 Storage Cabinets – Drums

20 Basic Storage Cabinets

22 Horizontal Storage Cabinets

23 Custom Engineered Cabinets

24 Fire Rated Storage Cabinets

26 Temperature Controlled Storage Cabinets

28 Storage Cabinet Options

DENIOS Storage Buildings30 Introduction to Chemical Storage Buildings

32 Premium Storage Buildings – 8’ Depth

34 Premium Storage Buildings – 10’ Depth

36 Premium Storage Buildings – 12’ Depth

38 Custom Engineered Storage Buildings

40 Fire Rated Storage Buildings

42 Temperature Controlled Storage Buildings

44 Storage Building Options

DENIOS Storage Lockers46 Introduction to Chemical Storage Lockers

48 K-Series Storage Lockers

49 K-Series Storage Lockers- Shelf Package

50 PK-Series Storage Lockers

52 N-Series Storage Lockers

55 IBC Storage Lockers

57 Specialty Storage Lockers

58 Custom Engineered Storage Lockers

59 Storage Locker Options

60 Enclosed HazMat Stations

DENIOS Liquid Barriers62 Automatic Doorway Spill Barriers

64 FM Approved Flood Barrier

65 HazBerm

Guide to Chemical Storage66 The Basics for the Handling and Storage of Flammable Chemicals –

Definitions

68 Storage of Flammable Liquids

69 Chemical Spill Containment Requirements

70 Storage of Organic Peroxides

72 Third Party Approvals

Table of Contents

Page 3: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

54

Introduction

Governmental codes and regulations dictate the correct selection and placement of hazardous chemical storage Lockers, Cabinets and Buildings. The characteristics of the stored material i.e. flammability, pH, material storage temperature, the size and type of container(s), the total quantity stored, and the storage location in relation to other structures will determine which code(s) and regulations pertain to your application.

Regulations and Codes of note that may affect your storage application are NFPA 30 “Storage of Flammable Liquids”, the IBC and IFC “International Building Code” and International Fire Code”, as well as the code of Federal regulations 40 CFR 264.175 concerning containment and 29 CFR 1910 (OSHA). Additionally independent third party testing agencies such as Factory Mutual have developed standards for the storage of flammable and other hazardous materials. DENIOS sells and produces Factory Mutual approved products.

DENIOS sales and engineering professionals are well versed in the requirements of National codes as they pertain to the storage of hazardous chemicals. However, the local code enforcement official or “Authority Having Jurisdiction” is the official closest to the situation with the responsibility to interpret the applicable codes in the light of all local factors. The local “AHJ” should always be consulted before purchasing any type of hazardous material storage equipment. DENIOS is always available to assist its customers with supplementary information to support approval process.

DENIOS’ Quality Assurance Program

As part of our ongoing commitment to quality, DENIOS maintains a formalized, structured Quality Assurance Program. This program mandates that designs are checked and rechecked by 3rd Party Engineering firms for structural loading, seismic, and other code compliance factors.

DENIOS equipment is also engineered to satisfy any number of regulatory agencies including:

NFPA – National Fire Protection Association

IBC – International Building Code

EPA – Environmental Protection Agency

OSHA – Occupational Safety and Health Administration

FM / FM Global – Factory Mutual Research

State Approval Departments

Relating to equipment manufacture, our Quality Assurance Program also insures all products are thoroughly inspected and tested before shipping. Tests range from, but are not limited to, pre-paint sump weld leak tests to temperature control tests for our heated and cooled structures. Testing is documented and overseen by our Engineering, Technical Sales, and Production staffs.

The DENIOS System

The DENIOS System of storage Lockers, Buildings, and Cabinets specifically address the material handling and processing needs of the client. All our structures are designed for placement indoors or out and can be easily relocated via crane or forklift. All provide options for fire rating, explosion protection, and temperature control. All designs address what and how much is being stored and how often it needs to be handled. And all are compliant.

Lockers: Engineered for small volume storage and processing, Lockers will accommodate 2-14 drums or 1-2 intermediate bulk containers. Available door styles allow for easy access to the chemicals by forklift. Typical uses include exterior storage of flammables and combustibles, remote storage and dispensing stations for truck and rail terminals, and insulated and heated storage for processing and freeze protection.

Cabinets: Designed for large volume storage needs, Cabinets come with single- or double-sided access and provide up to three tiers and 12 bays of storage space. A variety of door styles all allow for forklift access to every stored pallet of drums, thus simplifying handling and eliminating any personnel exposure to chemicals or fumes inside the Cabinet.

Buildings: Often utilized for housing dangerous processes such as mixing and pumping flammable paints and resins, Buildings provide a secure enclosure isolating any hazardous chemical dispensing, mixing, and processing away from personnel and the rest of the facility.

Overview – Codes and Regulations Governing the Storage of Hazardous Chemicals and Processes

Chemical Storage Equipment Selection Guide

DENIOS Spill Barrier

DENIOS Cabinet

DENIOS Locker

DENIOS Building

Chemical Storage Requirement

Size of Container

Quantity

55 gallon drumsQuantity

5 gallons or less

On Pallets?

Quantity

totes

more than 8 drums

roomful of totes

3-12 totes

1-2 totes

more than 40 5 gallon

containers

up to 36 pallets of containers

roomful of drums

yes no

less than 8 drums

less than 40 5 gallon

containers

Page 4: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

76

A Safer Storage Alternative

DENIOS is the pioneer in the development of Drum and IBC Storage Cabinets as a safer and more efficient alternative to walk-in buildings for chemical storage. The non-occupancy design of Cabinets, featuring full-face opening door styles, allows all materials to be moved via forklift, relieving personnel from having to enter a potentially hazardous environment. DENIOS manufactures the widest variety of styles of Cabinets available on the market today. Choose between single- or multi-tiered designs with either single- or double-sided access. Cabinets are suitable for indoor or outdoor placement and provide complete physical separation of stored chemicals from the surrounding facility and / or from other incompatible chemicals or ignition sources.

Applicable Regulations

DENIOS Cabinets meet the federal requirements for spill containment of hazardous liquids as regulated by the EPA (40 CFR).

DENIOS follows NFPA 30 regulations for specification compliance for outdoor (Flammable Storage Lockers) as well as indoor (Inside Liquid Storage Rooms) placement.

Although not designated as Occupancies or Structures, loads ratings for Cabinets (seismic, wind and roof) generally follow the same guidelines as provided for pre-fabricated buildings.

Cabinet designs are able to be provided with 3rd Party Engineering Approvals.

Due to local code variance and different enforcement philosophies, DENIOS always recommends checking with the local Authority Having Jurisdiction to verify that a specific configuration will comply with local codes.

For your further reference

Hazardous materials storage is regulated by EPA at the federal level by the Code of Federal Regulations (40 CFR).

At the state and local level, Fire Codes such as IFC, UFC, NFPA 30 (Storage and Handling of Flammable Liquids), Building Codes (UBC & IBC) and other requirements specific to State and Local jurisdictions may also apply. Typical local code issues include: wind load, snow load, seismic zone, fire rating and separation of flammable storage from the nearest building.

Benefit from our Experience

DENIOS has been designing and manufacturing chemical storage enclosures for over 20 years.

By working closely with customers in solving their unique storage challenges, we have been able to translate those solutions into standard products which can provide compliant storage for a majority of industries and applications.

Sizes and Styles:

48 standard configurations of base models

Individual storage bays sized for 2 or 3 pallets of drums or 2 or 3 IBC’s

Bays are arranged in configurations offering single-, double- or triple-tier heights

Models are available with single-sided or double-sided access (back-to-back bays)

All units are built to accommodate outdoor placement

Common Applications for Cabinets:

Segregated indoor or outdoor storage of flammable or other process chemicals

Separation of flammable liquids from general warehousing areas

Temperature controlled outdoor storage of raw materials

Higher volume waste accumulation and storage areas

Introduction to Chemical Storage Cabinets

Lifting eyes allow for easy relocation

Compliant spill containment sump sits below galvanized grating

Perfect for storing and handling palleted drums and IBC totes

Feet for forklift access allow for easy relocation

Choose between single-, double- and triple-tier models

Constructed of an 11 gauge tubular frame with 16 gauge steel walls

Multiple door styles (hinged, sliding,and roll-up) all provide full-face opening for easy access to drums / IBCs

Storing drums directly Storing drums on pallets

Storing IBCs Storing drums horizontally

How should substances be stored?

Sliding doors Hinged doors Roll-up doors

Freeze protected Range of door options- all doors lockable

Insulated system

International Fire Code (IFC) International Building Code (IBC) Code of Federal Regulations (CFR) Environmental Protection Act (EPA)

National Fire Protection Assn. (NFPA) Uniform Fire Code (UFC) Uniform Building Code (UBC) FM 6049

Roofing systems can be added to Cabinets or Buildings to create covered storage warehouses.

Fire Rated designs up to 4-hour, heating systems for Freeze Protected

Page 5: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

98

Designed and sized for 350 gallon IBC Totes or 55 gallon drums

Storage capacities from 2 to 12 totes or 8 to 48 drums

Choose between models with hinged or sliding doors, both allow easy access to totes / drums from outside the Cabinet

Sump volumes meet EPA, NFPA, and FM requirements

Low-viscous test ensures sumps are leak free

Constructed of heavy gauge, welded steel frames and walls

Available in single- and double-tiered designs with up to four storage bays

The hinged doors open full face, providing easy access to the stored drums.

The First Cabinet to Meet the Standard

Third party approvals for Hazardous Material Buildings have been around since 1991 in the form of FM class 6049. FM began approving hazardous material storage buildings with the first edition of CLASS 6049 in that year. This FM “standard” has remained the defacto standard in the US, unchallenged since that time. Manufacturers that receive FM approval have submitted their designs to a third party and then to FM for review in accordance with the standard. This includes reviewing the structural integrity including floor and snow loads in accordance with the standards and the ability of the building to withstand a specific wind which is especially important in coastal areas of the US. The standard further evaluates the integrity of fire rated walls and ceiling and certifies the stated containment sump capacity. Contrary to popular opinion, UL (Underwriters Laboratories) does not have a standard for these buildings, so no manufacturer can use the “UL listed” moniker with reference to their buildings.

A FM approved building should be labeled as such by the manufacturer. The text of the approval document prescribes what must be on the label. This includes place of manufacture, model no., design floor, wind and snow loads, and if applicable, the fire rating of the walls. It also includes whether the building is constructed with damage limiting construction (DLC) also known as deflagration panels, and the electrical classification and temperature classification of any and all electrical equipment installed on the building.

FM Approved Storage CabinetsExclusive to DENIOS, FM Approval (Class 6049) Non-Occupancy Storage Cabinets

DENIOS’ FM Approved fire rated Cabinet. DENIOS is presently the only manufacturer with FM Approved Cabinets.

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(Drums) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L30-1111 8 11 5 8 108 50 80 3,000 7,500 141

L30-1311 12 15 5 8 154 50 80 3,400 9,600 201

L30-1211 16 21 5 8 108 50 80 5,100 7,500 289

L30-1411 24 28 5 8 154 50 80 6,300 9,600 410

L30-2111 16 11 5 11 108 50 50 3,200 7,500 230

L30-2311 24 15 5 11 154 50 50 3,400 9,600 330

L30-2211 32 21 5 11 108 50 50 5,300 7,500 470

L30-2411 48 28 5 11 154 50 50 6,100 9,600 660

Exterior Dimensions (ft) Bay Dimensions (in)

L30-1113 8 11 6 8 108 50 80 3,000 7,500 141

L30-1213 16 21 6 8 108 50 80 5,100 7,500 289

L30-1413 24 28 6 8 154 50 80 6,300 9,600 410

L30-2113 16 11 6 11 108 50 50 3,200 7,500 230

L30-2213 32 21 6 11 108 50 50 5,300 7,500 470

L30-2413 48 28 6 11 154 50 50 6,100 9,600 660

Single-Sided Access — Hinged Doors

Single-Sided Access — Hinged Doors

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Page 6: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

1110

FM Approved Storage CabinetsIBC Totes

FM Approved Single-Tiered 2-hour Fire Rated Models are Designed to Accommodate Drums and / or IBCs

Capacities of 2 to 6 totes or 8 to 24 drums

Drums / totes rest on adjustable rack system, allowing storage flexibility

Models are equipped with roll-up fire doors for ease of access to stored chemicals and added safety in case of fire

Single-tier design features one or two storage bays

Constructed of heavy gauge welded steel and FM approved 2-hour fire rated walls and doors

Sump volumes meet EPA, NFPA, and FM requirements

Low-viscous test ensures sumps are leak free

Roll-up doors dimensions included in model box

FM Approved Double-Tiered Fire Rated Models are Designed Specifically for Drums or IBCs, Storing 16-48 Drums or 4-12 IBC Totes

These models provide the construction features listed at left but add a second tier for additional storage capacity

2-Hour Fire Rated – Drums / Totes

Roll-up fire doors allow Cabinets to remain open during work hours for easy access. A fuse link triggers the doors to close in the event of fire.

Drums / totes rest on adjustable rack system, allowing storage flexibility

L32-2112 16 11 7 13 108 49 50 7,000 7,500 227

L32-2312 24 16 7 13 162 49 50 8,500 9,600 340

L32-2212 32 22 7 13 108 49 50 12,500 7,500 479

L32-2412 48 32 7 13 162 49 50 15,000 9,600 706

FM approved Cabinets — Drums, Roll-up Doors

L33-2112 4 11 7 15 108 49 60 8,000 10,500 353

L33-2312 6 16 7 15 162 49 60 9,500 14,575 529

L33-2212 8 22 7 15 108 49 60 16,000 10,500 744

L33-2412 12 32 7 15 162 49 60 18,080 14,575 1,059

FM approved Cabinets — IBCs, Roll-up Doors

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(IBCs) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L31-1111 2 11 5 9 108 50 80 3,000 10,500 371

L31-1311 3 15 5 9 154 50 80 3,400 14,575 529

L31-1211 4 21 5 9 108 50 80 5,100 10,500 470

L31-1411 6 28 5 9 154 50 80 6,300 14,575 660

L31-2111 4 11 5 13 108 50 61 3,400 10,500 371

L31-2311 6 15 5 13 154 50 61 3,800 14,575 529

L31-2211 8 21 5 13 108 50 61 5,500 10,500 759

L31-2411 12 28 5 13 154 50 61 6,700 14,575 1,076

Exterior Dimensions (ft) Bay Dimensions (in)

Single-Sided Access — Hinged Doors

L31-1113 2 11 6 9 108 50 80 3,000 10,500 371

L31-1213 4 21 6 9 108 50 80 5,100 10,500 470

L31-1413 6 28 6 9 154 50 80 6,300 14,575 660

L31-2113 4 11 6 13 108 50 61 3,400 10,500 371

L31-2213 8 21 6 13 108 50 61 5,500 10,500 759

L31-2413 12 28 6 13 154 50 61 6,700 14,575 1,076

Single-Sided Access — Sliding Doors

Double-tiered storage Cabinet with hinged doors for 4 IBCs.

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(Drums/IBCs) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L32-1112 8/2 11 7 11 115 49 80 6,000 10,500 353

L32-1312 12/3 16 7 10 172 49 80 7,700 14,575 352

L32-1212 16/4 22 7 10 115 49 80 11,300 10,500 364

L32-1412 24/6 32 7 10 172 49 80 14,000 14,575 535

Exterior Dimensions (ft) Bay Dimensions (in)

FM approved Cabinets — Drums/IBCs, Roll-up Doors

These FM Approved Non-Combustible Storage Cabinets Are Specifically Designed and Sized for 350 Gallon IBC Totes

Storage capacities from 2 to 12 totes

Choose between models with hinged or sliding doors, both allow easy access to totes from outside the Cabinet

Sump volumes meet EPA, NFPA, and FM requirements

Low-viscous test ensures sumps are leak free

Constructed of heavy gauge, welded steel frames and walls

Available in single- and double-tiered designs with up to four storage bays

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Fire Rated designs up to 2-hour

Page 7: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

1312

These Storage Cabinets have been specially designed for Intermediate Bulk Containers (IBCs).

The sump volume exceeds mandatory Federal Regulations.

Full-face opening doors provide access to IBCs without the need to physically enter the structure.

Sump of heavy gauge steel for extended life

Sump welds are 100% inspected with a low-viscous test to insure leaktightness

Sump volumes meet EPA & NFPA requirements

Storage Cabinets for IBC TotesSingle-Sided Access

Single-tiered storage Cabinet with sliding doors (standard) for 3 IBC Totes saves facility space. Model in picture features optional fire rated design and fire suppression system.

L36-2503 4 21 5 9 120 50 80 4,200 10,500 388

L36-3142 6 27 5 9 154 50 84 5,400 14,575 465

L36-2515 8 21 5 12 120 50 60 5,600 10,500 388

L36-3145 12 27 5 12 154 50 60 6,800 14,575 465

Single-Sided Access — Sliding Doors

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(IBCs) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L36-2115 2 11 5 9 120 50 80 2,100 10,500 388

L36-3102 3 14 5 9 154 50 84 2,500 14,575 388

L36-2125 4 11 5 12 120 50 60 2,900 10,500 388

L36-3105 6 14 5 12 154 50 60 3,400 14,575 388

Exterior Dimensions (ft) Bay Dimensions (in)

Single-Sided Access — Hinged Doors

Added tier height and sump capacity makes tote Cabinets also appropriate for drum storage.

Addition of stands provides height to allow for spill-contained dispensing into small containers.

Coated with a durable, corrosion and weather resistant finish

Grounding package includes grounding lug, connection wire, and rod

Removable grating for easy clean-up

Extra strength, tubular steel construction

Page 8: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

1514

Double-sided Cabinets double storage capacity while not sacrificing immediate accessibility to the totes.

When indoor placement of the Cabinet is between aisles or a sufficient pad area exists outdoors, double-sided Cabinets offer additional capacity without losing access to drums.

Coated with a durable, corrosion and weather resistant finish

Grounding package includes grounding lug, connection wire, and rod

Storage Cabinets for IBC TotesDouble-Sided Access

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(IBCs) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L36-2140 4 11 9 9 120 50 80 3,400 10,500 388

L36-3108 6 14 9 9 154 50 84 4,200 14,575 431

L36-2155 8 11 9 12 120 50 60 4,400 10,500 388

L36-3111 12 14 9 12 154 50 60 5,100 14,575 431

Exterior Dimensions (ft) Bay Dimensions (in)

Double-Sided Access — Hinged Doors

L36-2521 8 21 10 9 120 50 80 6,900 10,500 715

L36-3148 12 27 10 9 154 50 84 8,900 14,575 867

L36-2533 16 21 10 12 120 50 60 8,800 10,500 715

L36-3151 24 27 10 12 154 50 60 10,700 14,575 867

Double-Sided Access — Sliding Doors

Single-tiered storage Cabinet with sliding Doors for 6 IBCs.

Single-tiered, double-sided Cabinet with fire suppression, a heated bay and roll-up doors (Custom engineered model, roll-up doors not standard).

DENIOS Cabinets are the most efficient and flexible chemical storage systems available.

Up to three storage tiers.

With double-sided access.

Hinged or Sliding Door.

Multiple-tiered units provide secure, separate platforms for all pallets – no need to double-stack, greatly reducing material handling risks

Move only the pallet(s) you need, eliminating any unnecessary double handling

Sump volumes meet EPA and other regulatory requirements

Double-sided access increases capacity without decreasing accessibility.

Note: Due to their overall height, all triple-tiered units are produced and shipped in two sections. Assembly on site is easy using our complete, step-by-step instructions.

Choose between sliding and roll-up door models. Designs provide up to three storage tiers.

Sump of heavy gauge steel for extended life

Sump welds are 100% inspected with a low-viscous test to insure leaktightness

Sump volumes meet EPA & NFPA requirements

Removable grating for easy clean-up

Extra strength, tubular steel construction

Double-sided access designs keep all stored IBCs within easy access of the fork truck operator.

Page 9: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

1716

All Cabinet door styles provide easy access to stored drums or totes.

DENIOS has the most complete line of cabinets for storing drums and IBC’s.

Cabinets provide highly efficient storage. All products can be accessed from outside the cabinet. No need to manhandle individual drums.

Let DENIOS help you select the best configuration for your facility:

2 or 3 pallet bay sizes

1 or 2 bay lengths

1, 2, or 3 tiers high

Single- or double-sided access

Spill sumps located in the base of each unit.

Cabinets may be specially ordered with a variety of door styles:

Hinged

Sliding

Roll-up

PVC curtain on application

No doors (indoor placement)

When facility floor space is at a premium, our triple-tier Cabinets can provide the most compact yet efficient storage system available. Each level is provided with its own grating platform for easy and secure pallet loading.

Storage Cabinets for DrumsSingle-Sided Access

Double-tiered storage Cabinet with custom paint color and hinged doors holds 16 drums.

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(Drums) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L16-3102 8 11 5 9 120 50 88 2,100 7,500 158

L39-3102 12 14 5 9 154 50 88 2,500 9,600 202

L16-3105 16 11 5 10 120 50 50 2,500 7,500 158

L39-3105 24 14 5 10 154 50 50 3,000 9,600 202

Exterior Dimensions (ft) Bay Dimensions (in)

Single-Sided Access — Hinged Doors

L16-3142 16 21 5 9 120 50 88 4,400 7,500 323

L39-3141 24 27 5 9 154 50 88 5,400 9,600 411

L16-3145 32 21 5 10 120 50 50 5,000 7,500 323

L39-3145 48 27 5 10 154 50 50 6,70 9,600 411

L39-3151 72 27 5 15 154 50 50 7,800 9,600 411

Single-Sided Access — Sliding Doors

L39-3109 36 14 5 17 154 50 50 4,000 9,600 202

Single-Sided Access — Roll-up Doors

Note: Due to their overall height, all triple-tiered units are produced and shipped in two sections. Assembly on site is easy using our complete, step-by-step instructions.

Full selection of options including:

2- and 4-hour fire rated walls

UL classified fire doors with automatic closing devices

Fire suppression systems

Explosion-proof mechanical ventilation

Fume or leak detection / alarm systems

Double-tiered storage Cabinet with hinged doors holds 16 drums.

Page 10: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

1918

DENIOS Cabinets are the most efficient and flexible chemical storage systems available.

Up to three storage tiers.

With double-sided access.

Hinged or Sliding Door.

Move only the pallet(s) you need, eliminating any unnecessary double handling

Multiple-tiered units provide secure, separate platforms for all pallets – no need to double-stack, greatly reducing material handling risks

Sump volumes meet EPA and other regulatory requirements

Passive ventilation prevents fume buildup

Grounding package included as standard equipment

Storage Cabinets for DrumsDouble-Sided Access

Double-tiered storage Cabinet with sliding doors holds 96 drums.

Double-sided access, fire rated Cabinet fits well in existing aisle way of distribution hub; allowing interior storage of small containers of flammables.

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(Drums) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L16-3122 16 11 9 9 120 50 88 3,600 7,500 297

L39-3121 24 14 9 9 154 50 88 4,200 9,600 381

L16-3125 32 11 9 10 120 50 50 4,100 7,500 297

L39-3125 48 14 9 10 154 50 50 4,800 9,600 381

Exterior Dimensions (ft) Bay Dimensions (in)

Double-Sided Access — Hinged Doors

L39-3130 72 14 9 17 154 50 50 6,200 9,600 431

Single-Sided Access — Roll-up Doors

L16-3162 32 21 9 9 120 50 88 7,300 7,500 600

L39-3161 48 27 10 9 154 50 88 8,900 9,600 767

L16-3165 64 21 9 10 120 50 50 8,400 7,500 600

L39-3164 96 27 10 10 154 50 50 12,400 9,600 767

L39-3167 144 27 10 15 154 50 50 12,500 9,600 867

Single-Sided Access — Sliding Doors

Double-tiered storage Cabinet with hinged doors on both sides, load capacity 48 drums.

Increase Capacity Without Sacrificing Accessibility

When indoor placement of the Cabinet is between aisles or a sufficient pad area exists outdoors, double-sided Cabinets offer additional capacity without losing access to drums.

Sump of heavy gauge steel for extended life

Sump welds are 100% inspected with a low-viscous test to insure leaktightness

Sump volumes meet EPA & NFPA requirement

Removable grating for easy clean-up

Extra strength, tubular steel construction

Coated with a durable, corrosion and weather resistant finish

Grounding package includes grounding lug, connection wire, and rod

Note: Due to their overall height, all triple-tiered units are produced and shipped in two sections. Assembly on site is easy using our complete, step-by-step instructions.

Page 11: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

2120

Standard Features:

Choose between models with hinged, roll-up, or sliding doors- all providing easy access to stored drums

Compliant spill sump captures leaks and spills

Designs provide storage capacities for 8, 16, and 32 drums

Wide door openings provide forklift access to palletized drums- no need for personnel to enter the Cabinet

Welded steel tubular construction with 16 gauge walls stands up to most industrial environments

These DENIOS Cabinet Designs Provide the Most Efficient and Economical Means to Store 55 Gallon Drums

Standard Features Include:

Compliant spill containment sumps in base

Passive ventilation for fume control

Rugged 11-gauge solid welded frame

Rust inhibiting coated steel

Locking mechanism for added security

Basic Storage Cabinets

Cabinet easily stores 16 drums and features a space saving roll-up door.

Model L20-2213 utilizes a sliding door for easy access and offers a 32 drum storage capacity

Double-tier units save facility space. Roll-up door includes chain hoist for easy operation. Accommodates up to 4 pallets of drums.

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(Drums) Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L20-1111 8 10 5 9 108 48 88 1,800 3,200 160

L20-2111 16 10 5 10 108 48 50 2,100 3,200 160

Exterior Dimensions (ft) Bay Dimensions (in)

Basic Storage Cabinet — Drums, Hinged Doors

L20-2213 32 19 5 10 108 48 50 3,800 3,200 320

Basic Storage Cabinet — Drums, Sliding Doors

L20-1112 16 10 5 12 108 48 50 2,300 3,200 160

Basic Storage Cabinet — Drums, Roll-up Doors

L14-1005 8 11 5 9 120 50 69 2,100 7,500 158

L14-1030 12 14 5 9 154 50 69 2,500 9,600 202

L14-2005 16 11 5 10 120 50 50 2,600 7,500 158

L14-2030 24 14 5 10 154 50 50 3,000 9,600 202

Basic Storage Cabinet — Drums, Roll-up Doors

L14-8010 2 11 5 9 120 50 80 3,000 10,500 388

L14-8020 4 11 5 12 154 50 60 3,500 10,500 388

Basic Storage Cabinet — IBCs, Roll-up Doors

Material handling made easy!

No entry required – easy-open roll-up doors allow immediate access to all materials from outside the Cabinet

Design keeps doors clear of forklift or other traffic and out of the wind

Page 12: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

2322

Horizontal Storage Cabinets Custom Engineered Storage Cabinets

Heated Cabinet for processing stored chemicals.

Engineered Solutions for Your Unique Applications

DENIOS Engineering leads the industry in the design and manufacture of customized enclosures designed for the safe storage of chemicals.

We provide solutions for the safe storage of:

Flammables or flammable / explosive processes

Acids or caustic chemicals

Temperature sensitive chemicals, whether for preservation heating / cooling or process heating / cooling

Dispense & Store Hazardous materials over a containment sump while providing spill compliance with Federal Regulations.

55-gallon drum dispensing station

Sump welds are 100% inspected with a low-viscous test to insure leaktightness

Fully welded tubular frame construction

Double- or triple-tiered models maximize storage efficiency

Passive ventilation included

Grounding package includes grounding lug, connector and rod

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(Drums) Length Depth Height Length Depth Tier

Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L12-3104 24 14 5 7 13 4 — 2,900 9,600 202

L12-3107 36 14 5 12 13 4 — 3,400 9,600 202

L12-3144 48 27 5 7 26 4 — 5,700 9,600 411

L12-3150 72 27 5 12 26 4 — 6,300 9,600 411

Exterior Dimensions (ft) Bay Dimensions (ft)

Single-Sided Access — Open Storage

Model Number

Tiers / Bays Structure

Capacity per Cabinet

(Drums) Length Depth Height Length Depth Tier

Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L16-3182 10 14 5 9 13 4 35 3,300 9,600 208

L16-3186 15 14 5 10 13 4 29 3,400 9,600 208

L16-3190 20 27 5 9 26 4 35 6,100 9,600 417

L16-3193 30 27 5 10 26 4 29 6,300 9,600 417

Single-Sided Access — Sliding Doors

Exterior Dimensions (ft) Bay Dimensions (ft)

Double-tiered Cabinet out-fitted for horizontal placement of drums and with an optional vinyl curtain door.

Heated and fire rated Cabinet also provides explosion relief panels for the storage of combustibles.

Open Storage Systems

Ideal for Indoor Storage of Non-Flammables and Non-Combustibles, where fumes and separation are not factors

Constructed of heavy gauge steel for extended life

Sump volumes meet or exceed EPA requirements

Removable, galvanized steel grating

Coated with a durable, corrosion resistant finish

Greater sump volumes available upon request

4-bay / double-tiered storage system hold up to 48 drums.

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Page 13: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

2524

Fire rated, heated and cooled Cabinet also provides explosion proof lighting and temperature controls.

DENIOS Fire Rated Cabinets

Primarily designed for the storage of flammable chemicals or products

Provides for indoor or outdoor placement – multiple storage tiers and single- or double-sided access to stored chemicals

Cabinet with self closing doors to keep fires outside of or limited to the inside of the enclosure

Choose from Cabinet designs for chemical storage or Buildings for housing chemicals and chemical processes.

Great for distribution facilities with inventories of flammable products / chemicals. Cabinets can easily be placed in existing storage aisles – easing material handling and eliminating the need for costly reconstruction.

Engineered Options for DENIOS Fire Rated Enclosures may include:

UL approved firewalls, designs include 2- and 4-hour rated construction

Deflagration panels to redirect destructive forces in case of an explosion

Fire, fume, or leak detection alarms

Dry or wet fire suppression systems

Ventilation systems to remove noxious or ignitable fumes

Spill containment sumps which meet / exceed EPA, UFC, NFPA, and OSHA regulations

Heating / cooling options for temperature sensitive chemicals

Special coatings and materials for the storage of acids, caustics, or corrosives

Fire Rated Storage Cabinets

Fire rated Buildings can house and segregate hazardous processes, like pumping, away from other facilities and personnel.

Fire rated Cabinets allows for easy loading / unloading of stored drums, keeping personnel out of a poten-tially hazardous environment. Cabinet shown has double-sided access utilizing fire rated roll-up doors.

Fire rated roll-up doors close automatically in case of a fire in or outside of the cabinet.

Fire Rated designs up to 4-hour, heating systems for Freeze Protected

Page 14: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

2726

Heating and Cooling Options for Preserving or Processing Chemicals

DENIOS Temperature Controlled Enclosures can be designed for preservation heating / cooling of temperature sensitive chemicals or provide higher temperatures for process heating

Designs provide thermostatically controlled steam, heat transfer fluid, or electrical heat and air cooling systems

Air circulation / ventilation systems ensure proper heat / cooling distribution

Enclosures are constructed with fully insulated, fire resistant walls and doors

Typically employ hinged doors with perimeter gasketing and multi-point latching locks to maintain internal temperatures

As with all DENIOS enclosures, structures feature an enclosed, compliant spill containment sump

Safe Solutions for Chemical Processing

Process heating / cooling of chemicals has inherent dangers. DENIOS enclosures address many of those risks through their standard construction and with many safety options.

Insulated, 2-hour fire rated wall construction (standard on all models)

Explosion relief panels

Over temperature controls / alarm systems

Explosion-proof mechanical exhaust ventilation

In addition, all models are suitable for outdoor placement, away from personnel and facilities

Can achieve temperature ranges from 0°F to 300°F

Industries served by DENIOS temperature controlled enclosures include:

Foods and flavorings

Pharmaceuticals

Cosmetics

Paint and ink manufacturing

Chemicals

Rubber and plastics

Effective solutions for thermal processing of materials.

Optimal solution for thermal treatment of large and small amounts of stored material

High capacity: up to 48 x 55 gallon drums or 12 IBCs

Heat output and air circulation are perfectly adjusted and are combined with uniform heat distribution to ensure a uniform temperature profile

Temperature Controlled Storage Cabinets

Heating Cabinets with electric heating and circulating air fan for optimal air circulation.

Double-sided Cabinet used for processing heating / cooling of flavorings.Fire rated Cabinet with cooling for oils / lubricants.

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Page 15: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

2928

Fire prevention air vents

Where air circulation is required, fan-forced air vents can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container.

Fire dampers

Where air circulation is required, fire dampers can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container.

Storage Cabinet Options

PE and stainless steel sump liners

When storing acids, alkalis or other aggressive substances, it is recommended that sump liners be installed. These can be manufactured both in PE and stainless steel. Further information regarding sumps can be found in our main catalog.

Grating

DENIOS fire proof containers are fitted with galvanized grating as standard. Alternative grating are available however and when storing aggressive substances, stainless steel grating or synthetic material grating can be provided.

Grounding kits

Grounding kits are required to avoid an electric discharge between the container and other conductive units. All DENIOS HazMat containers can be fitted with an accessory to avoid discharges. These are highly recommended for containers storing explosive materials.

Special paint finishes

DENIOS offers internal as well as external multi color finishes.

Cooling

DENIOS engineering provide precise solutions to temperature control, such as cooling units and air conditioning systems. With DENIOS expertise we always have a solution for your needs.

Heating

Many substances require optimal heating to maintain quality. DENIOS provides heating systems using electric or steam heat.

Insulation

The walls of our HazMat insulated system containers guard against loss of energy, temperature and frost damage. DENIOS use different types of material ranging from a thickness of 60 to 125 mm.

Temperature regulators

DENIOS uses the most up-to-date temperature regulators to ensure user friendly programming of required temperatures. The majority of DENIOS regulators can be programmed and adjusted on the main control box on the exterior of the container.

System monitoring

To monitor important features such as temperature, pressure, air quality etc., it is possible to install an assortment of sensors to the container. A continuous monitoring system can be installed to your specific requirement and standards. The system can be monitored in situ or attached to the main computer system which ensures a regular and safe way to monitor air flow etc.

Gas detectors

If poisonous gases are allowed to escape then early detection is a vital requirement. DENIOS can provide gas warning detectors where a pre-set level can be set and when reached an audible or visual alarm or both will occur.

Leak Detector

Leak detectors can be installed in sumps to detect any leakage from container contents. The alarm can be audible, visual or both. Early detection allows prompt action to be taken.

Alarm lights

In addition to audible alarms DENIOS can provide alarm lights to work in conjunction with the main alarm system, enhancing the warnings effectiveness to personnel.

Sprinkler systems

Sprinkler systems provide extra safety in containers used to store flammable and non-flammable substances. DENIOS offers several types of sprinkler systems. We can provide, standard, heavy foam, powder, Novec or CO2 systems.

Smoke / heat detectors & fire alarms

For the protection of fire proof containers it is important that an early warning system is installed. DENIOS uses certified multi sensors for this purpose. Smoke and fire detection is quick and reliable and can be installed in conjunction with a siren. The alarm system can be connected to the main alarm system.

Storage Cabinet Options

Page 16: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

3130

Applicable Regulations

DENIOS designs its HazMat storage buildings to be compliant with all recognized National Codes and generally accepted national standards.

In addition to federal and local regulations, risk management organizations such as Factory Mutual (FM Global) have developed their own standards.

Most DENIOS HazMat storage buildings for outdoor placement can be shipped bearing the FM approval label.

For your further reference

Hazardous materials storage is regulated by EPA at the federal level by the Code of Federal Regulations (40 CFR).

At the state and local level, Fire Codes such as IFC, UFC, NFPA 30 (Storage and Handling of Flammable Liquids), Building Codes (UBC & IBC) and other requirements specific to State and Local jurisdictions may also apply.

Typical local code issues include: wind load, snow load, seismic zone, fire rating and separation of flammable storage from the nearest building.

Due to local code variance and different enforcement philosophies, DENIOS always recommends checking with the local Authority Having Jurisdiction to verify that a specific configuration will comply with local codes.

Sizes and Styles

Available in 8, 10 and 12 foot widths with lengths from 8 to 52 feet

All units are built to accommodate indoor or outdoor placement. Door styles include hinged doors and roll-up doors and can be designed in multiple configurations

Non-Combustible, fire rated, and temperature controlled models available

Popular Applications

Process enclosures: Pumping, mixing, dispensing, paint kitchen

Remote storage: Waste collection, fuel dispensing

Agricultural chemical storage: Parks and recreation, golf courses

Secured storage and separation: Toxic, dangerous, valuable materials

HazMat storage of drums handled by hand

Fuel component enclosures

Battery testing enclosures

Introduction to Chemical Storage Buildings

This 28 x 8 storage Building holds up to 39 drums. Seen here with optional door sets and integrated shelving package.

16 x 8 storage Building can be engineered for the storage of chemicals or housing of chemical processes.

DENIOS Building designs include 2- and 4-hour fire rated construction.

Lifting eyes and forklift access allow for easy relocation

Building with optional shelving and door sets for oils and lubricants storage and processing

Choose for multiple door sets

Designed for occupancy by personnel

Perfect for storing and handling unpalleted drums and housing hazardous processes

Constructed of an 11 gauge tubular frame with 16 gauge steel walls

8, 10, and 12 foot depths allow for addition of shelving for smaller containers / tools

Compliant spill containment sump sits below galvanized grating

Secured and Store Hazardous Chemicals and Processes Away from Personnel / Facilities

DENIOS Chemical Storage Building designs provide more storage flexibility, enhancing the efficiency of the structure over competitive models. Choose from over 25 standard sizes to provide the optimal space for storing your hazardous chemicals or processes.

Designed for occupancy by personnel, DENIOS also provides numerous options to enhance safety, efficiency, and security in all our Buildings. DENIOS Chemical Storage Buildings carry FM Approval.

Fire Rated designs up to 4-hour, heating systems for Freeze Protected

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Page 17: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

3332

This 40 x 8 Building holds up to 57 drums. Seen here with optional lighting and heating package.

The Solution to Securing and Storing Hazardous Chemicals and Processes

Walk-In / Occupancy Enclosed Storage Buildings are ideal for storing drums and smaller containers when frequent access is required to store, mix or dispense. Once inside, you are able to work with the materials over an internal spill sump.

These Premium non-combustible structures feature solidly welded frame construction and

Premium Storage Buildings – 8‘ Depth

Standard 10 x 8 Building with optional crane for material handling.

Provides storage for up to 9 drums. Customized Building provides added height and storage for up to 12 drums. Standard model is L53-1008.

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Maximize your storage capabilities! Add shelving around the perimeter of the Walk-In Building to store small containers along with your 55-gallon drums.

FM Approved

Doors provided with inside release features

Standard designs feature a single leaf door; buildings can be constructed with more door sets if required

Shelving may be added to store small containers

Ramps are available for manual drum loading

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

can be fire rated, insulated, heated or cooled as individual requirements dictate.

Numerous sizes and options to match your specific requirements.

Corrosion and weather resistant finish

Removable, galvanized steel grating for easy clean-up of spills

Sump volumes which exceed EPA, UFC, NFPA, and OSHA regulations

Grounding package includes grounding lugs, connector and rod

Relocatable via forklift or crane

Interior dimensions shown are for non-combustible units. Fire rated designs differ, please contact factory for details.

Model Number

Drum Cap Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L53-0808-FM 9 94 93 103 89 88 86 2900 19036 205L53-1008-FM 12 118 93 103 113 88 86 3900 24169 260L53-1208-FM 15 142 93 103 137 88 86 3900 29303 315L53-1408-FM 18 166 93 103 161 88 86 4300 34436 370L53-1608-FM 21 190 93 103 185 88 86 4800 39569 425L53-1808-FM 24 214 93 103 209 88 86 5300 44703 480L53-2008-FM 27 238 93 103 233 88 86 5800 49836 536L53-2208-FM 30 262 93 103 257 88 86 6300 54969 591L53-2408-FM 33 286 93 103 281 88 86 6800 60103 646L53-2608-FM 36 310 93 103 305 88 86 7300 65236 701L53-2808-FM 39 334 93 103 329 88 86 7700 70369 756L53-3008-FM 42 358 93 103 353 88 86 8200 75503 811L53-3208-FM 45 382 93 103 377 88 86 8700 80636 867L53-3408-FM 48 406 93 103 401 88 86 9200 85769 922L53-3608-FM 51 430 93 103 425 88 86 9700 90903 977L53-3808-FM 54 454 93 103 449 88 86 10200 96036 1032L53-4008-FM 57 478 93 103 473 88 86 10700 101169 1087L53-4208-FM 60 502 93 103 497 88 86 11100 106303 1142L53-4408-FM 63 526 93 103 521 88 86 11600 111436 1198L53-4608-FM 66 550 93 103 545 88 86 12100 116569 1253L53-4808-FM 69 574 93 103 569 88 86 12600 121703 1308L53-5008-FM 72 598 93 103 593 88 86 13100 126836 1363L53-5208-FM 75 622 93 103 617 88 86 13600 131969 1418

Exterior Dimensions (ft) Bay Dimensions (in)

Buildings — 8’ Depth

Page 18: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

3534

Gain additional sidewall space with our 10-foot nominal depth Buildings

Added space great for shelves holding smaller containers

Provides more room for personnel to maneuver with mixing or dispensing applications

Ramps available to ease drum handling in and out of the Building

Typical Applications:

Storage of multiple, manually handled drums and small containers

Housing and enclosing of hazardous processes such as pumping, mixing, and dispensing

Secured, isolated storage of toxic or dangerous chemicals

Satellite supply storage for fuels or lubricants.

Waste collection and sorting

Premium Storage Buildings – 10‘ Depth

16 x 10 Building holds up to 28 drums. Shown here with optional door set.

20 x 10 non-combustible Building with added ramp.

10 x 10 Building with options including alarm, fire suppression system, and mechanical ventilation.

Model Number

Drum Cap Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L53-1010-FM 16 118 118 103 113 112 86 4500 30761 330L53-1210-FM 20 142 142 103 137 112 86 4500 37294 400L53-1410-FM 24 166 166 103 161 112 86 5000 43828 470L53-1610-FM 28 190 190 103 185 112 86 5600 50361 541L53-1810-FM 32 214 214 103 209 112 86 6100 56894 611L53-2010-FM 36 238 238 103 233 112 86 6700 63428 681L53-2210-FM 40 262 262 103 257 112 86 7200 69961 751L53-2410-FM 44 286 286 103 281 112 86 7800 76494 821L53-2610-FM 48 310 310 103 305 112 86 8300 83028 891L53-2810-FM 52 334 334 103 329 112 86 8900 89561 961L53-3010-FM 56 358 358 103 353 112 86 9400 96094 1031L53-3210-FM 60 382 382 103 377 112 86 10000 102628 1102L53-3410-FM 64 406 406 103 401 112 86 10500 109161 1172L53-3610-FM 68 430 430 103 425 112 86 11000 115694 1242L53-3810-FM 72 454 454 103 449 112 86 11600 122228 1312L53-4010-FM 76 478 478 103 473 112 86 12100 128761 1382L53-4210-FM 80 502 502 103 497 112 86 12700 135294 1452L53-4410-FM 84 526 526 103 521 112 86 13200 141828 1522L53-4610-FM 88 550 550 103 545 112 86 13800 148361 1593L53-4810-FM 92 574 574 103 569 112 86 14300 154894 1663L53-5010-FM 96 598 598 103 593 112 86 14900 161428 1733L53-5210-FM 100 622 622 103 617 112 86 15400 167961 1803

Exterior Dimensions (ft) Bay Dimensions (in)

Buildings — 10’ Depth

10 x 10 fire rated Building, optional ramp eases material handling in and out of the building.

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

40 x 10 Building holds up to 76 drums. Shown here with lighting and fan forced heating system.

Interior dimensions shown are for non-combustible units. Fire rated designs differ, please contact factory for details.

Page 19: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

3736

Extra deep 12-foot buildings provide floor and wall space for storage and process activities

Added depth provides optimum storage and processing flexibility

Multiple door sets available for ease of handling and access

Interior walls can be added to separate processes or stored chemicals

Numerous options available for all buildings, including 2- and 4-hour fire rated construction

Designs provide forklift access and lifting eyes for easy relocation

Typical Applications:

Flammable storage where drums must be handled individually

Remote storage of regulated chemicals such as pesticides and other toxic or hazardous materials

Pre-fabricated process enclosures to provide separation of dangerous activities from other work areas

Collection and temporary storage of wastes

Premium Storage Buildings – 12‘ Depth

12 x 12 with fire rated construction and electrical package.

Added depth of 12 foot Buildings accommodates the addition of shelving systems.

Model Number

Drum Cap Length Depth Height Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

L53-1212-FM 25 142 135 103 137 130 86 5100 43288 464L53-1412-FM 30 166 135 103 161 130 86 5700 50872 546L53-1612-FM 35 190 135 103 185 130 86 6300 58455 627L53-1812-FM 40 214 135 103 209 130 86 6900 66038 708L53-2012-FM 45 238 135 103 233 130 86 7500 73622 790L53-2212-FM 50 262 135 103 257 130 86 8100 81205 871L53-2412-FM 55 286 135 103 281 130 86 8700 88788 952L53-2612-FM 60 310 135 103 305 130 86 9400 96372 1034L53-2812-FM 65 334 135 103 329 130 86 10000 103955 1115L53-3012-FM 70 358 135 103 353 130 86 10600 111538 1197L53-3212-FM 75 382 135 103 377 130 86 11200 119122 1278L53-3412-FM 80 406 135 103 401 130 86 11800 126705 1359L53-3612-FM 85 430 135 103 425 130 86 12400 134288 1441L53-3812-FM 90 454 135 103 449 130 86 13000 141872 1522L53-4012-FM 95 478 135 103 473 130 86 13600 149455 1603L53-4212-FM 100 502 135 103 497 130 86 14200 157038 1685L53-4412-FM 105 526 135 103 521 130 86 14900 164622 1766L53-4612-FM 110 550 135 103 545 130 86 15500 172205 1847L53-4812-FM 115 574 135 103 569 130 86 16100 179788 1929L53-5012-FM 120 598 135 103 593 130 86 16700 187372 2010L53-5212-FM 125 622 135 103 617 130 86 17300 194955 2091

Exterior Dimensions (ft) Bay Dimensions (in)

Buildings — 12’ Depth

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

24 x 12 processing Building with XP lighting, alarm and heating package. Shown with optional door set.

12 x 12 Building with 144 square feet holds up to 25 drums. Shown with optional fire rated package. Interior dimensions shown are for non-combustible units. Fire rated designs differ, please contact factory for details.

Page 20: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

3938

Engineered Solutions For Your Unique Applications

DENIOS Engineering leads the industry in the design and manufacture of customized enclosures designed for the safe storage of chemicals.

We provide solutions for the safe storage of:

Flammables or flammable / explosive processes

Acids or caustic chemicals

Temperature sensitive chemicals, whether for preservation heating / cooling or process heating / cooling

Completely customized enclosures provide added access for personnel, material handling equipment, or the incorporation of the structure into your existing processes or facilities

Buildings for housing hazardous processes – Process Buildings

With the addition of standard and custom options and engineered construction, DENIOS Buildings are frequently utilized to house hazardous processes like pumping, mixing, heating, and dispensing. Designs include 2- and 4-hour fire rated construction as well as damage limited wall panels.

Custom Engineered Storage Buildings

Customized chemical storage Building engineered to accommodate and function with customer processing equipment.

Customized oil storage unit provides access to drums via forklift as well as a manway.

Fire rated Building with custom door set to improve access.

This engineered building for the storage and processing of acids includes personnel showers, material handling crane, manway door and fiberglass grating (above and right).

Buildings allow for remote placement, while still providing ample work space for periodic occupancy of personnel.

Process Applications include:

Paint kitchens

Pumping operations

Battery testing enclosures

Fuel component enclosures

DENIOS Engineering provides you:

A complete understanding of hazardous chemicals and chemical processes

Expert knowledge of regulations and fire codes

A technical sales staff and engineering department working with you every step of the way in designing a safe storage solution for your unique application

Page 21: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

4140

Engineered Options for DENIOS Fire rated Enclosures may include:

UL approved firewalls, designs include 2- and 4-hour rated construction

Deflagration panels to redirect destructive forces in case of an explosion

Fire, fume, or leak detection alarms

Dry or wet fire suppression systems

Ventilation systems to remove noxious or ignitable fumes

Spill containment sumps which meet / exceed EPA, UFC, NFPA, and OSHA regulations

Heating / cooling options for temperature sensitive chemicals

Special coatings and materials for the storage of acids, caustics, or corrosives

Fire Rated Storage BuildingsCustomized Chemical Storage and Processing Solutions

Customized chemical storage Building with optional door location, fire rated construction, and heating system.

Building provides fire suppression, explosion proof lights and mechanical ventilation.

Fire rated Building with added door measures 30 x 10 and has a 56 drum storage capacity.Fire rated building without spill containment sump for the housing of power generators.Typical fire suppression systems feature dry chem extinguishers. Fire alarms, fume and leak detector systems are also available.

Provide the Added Security of Fire Rated Construction

DENIOS Engineering leads the industry in the design and manufacture of customized enclosures designed for the safe storage of chemicals.

DENIOS Fire Rated Buildings

Primarily used for the storage flammable chemicals or processes

Provide pre-engineered rooms separating flammable chemicals and/or processes such as pumping, dispensing, or mixing

Designs allow for indoor or outdoor placement Interior walls can be added to separate dangerous chemicals from processes

DENIOS Engineering provides you:

A complete understanding of hazardous chemicals and chemical processes

Expert knowledge of regulations and fire codes

A technical sales staff and engineering department working with you every step of the way in designing a safe storage solution for your unique application

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Page 22: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

4342

Designed and Manufactured for Safe Chemical Processing

Process heating / cooling of chemicals has inherent dangers. DENIOS enclosures address many of those risks through their standard construction and with many safety options.

Insulated, 2-hour fire rated wall construction (standard on all models)

Explosion relief panels

Over temperature controls / alarm systems

Explosion-proof mechanical exhaust ventilation

In addition, all models are suitable for outdoor placement, away from personnel and facilities

Fire rated construction and fire suppression systems. May include self-closing roll-up fire doors

Chemical leak and fume detectors / alarms

Air circulation / removal systems

XP lighting and electrical for hazardous areas / applications

Manual and automatic cranes for material handling

150 mph / hurricane rated construction

DENIOS Temperature Controlled Enclosures can be Designed for Preservation Heating / Cooling of Temperature Sensitive Chemicals or Provide Higher Temperatures for Process Heating.

Temperature Controlled Storage Buildings

Heated and cooled storage Building with fire suppression system, fire rated construction, and explosion-relief panels designed to house automotive paint pumping equipment.

Custom Building provides heating/cooling, explosion-proof lighting, and explosion relief panels for the storage and processing of combustibles.

For the Safe Processing or Preservation Heating / Cooling of Chemicals

Process or preservation cooling and heating (steam or electrical). Cool to 0°F, heat to 300°F

Air circulation / ventilation systems ensure proper heat / cooling distribution

Enclosures are constructed with fully insulated, fire resistant walls and doors

Typically employ hinged doors with perimeter gasketing and multi-point latching locks to maintain internal temperatures

As with all DENIOS enclosures, structures feature an enclosed, compliant spill containment sump

Interior of Building shows electric heating unit, explosion proof light, and XP controls.

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Page 23: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

4544

PE and stainless steel sump liners

When storing acids, alkalis or other aggressive substances, it is recommended that sump liners be installed. These can be manufactured both in PE and stainless steel. Further information regarding sumps can be found in our main catalog.

Grating

DENIOS fire proof containers are fitted with galvanized grating as standard. Alternative grating are available however and when storing aggressive substances, stainless steel grating or synthetic material grating can be provided.

Grounding kits

Grounding kits are required to avoid an electric discharge between the container and other conductive units. All DENIOS HazMat containers can be fitted with an accessory to avoid discharges. These are highly recommended for containers storing explosive materials.

Special paint finishes

DENIOS offers internal as well as external multi color finishes.

Fire prevention air vents

Where air circulation is required, fan-forced air vents can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container.

Cooling

DENIOS engineering provide precise solutions to temperature control, such as cooling units and air conditioning systems. With DENIOS expertise we always have a solution for your needs.

Heating

Many substances require optimal heating to maintain quality. DENIOS provides heating systems using electric or steam heat.

Insulation

The walls of our HazMat insulated system containers guard against loss of energy, temperature and frost damage. DENIOS use different types of material ranging from a thickness of 60 to 125 mm.

Temperature regulators

DENIOS uses the most up-to-date temperature regulators to ensure user friendly programming of required temperatures. The majority of DENIOS regulators can be programmed and adjusted on the main control box on the exterior of the container.

System monitoring

To monitor important features such as temperature, pressure, air quality etc., it is possible to install an assortment of sensors to the container. A continuous monitoring system can be installed to your specific requirement and standards. The system can be monitored in situ or attached to the main computer system which ensures a regular and safe way to monitor air flow etc.

Gas detectors

If poisonous gases are allowed to escape then early detection is a vital requirement. DENIOS can provide gas warning detectors where a pre-set level can be set and when reached an audible or visual alarm or both will occur.

Leak Detector

Leak detectors can be installed in sumps to detect any leakage from container contents. The alarm can be audible, visual or both. Early detection allows prompt action to be taken.

Alarm lights

In addition to audible alarms DENIOS can provide alarm lights to work in conjunction with the main alarm system, enhancing the warnings effectiveness to personnel.

Sprinkler systems

Sprinkler systems provide extra safety in containers used to store flammable and non-flammable substances. DENIOS offers several types of sprinkler systems. We can provide, standard, heavy foam, powder, Novec or CO2 systems.

Fire dampers

Where air circulation is required, fire dampers can be installed featuring automatic closing air vent mechanisms. These close automatically as soon as fire is detected, thus cutting off the supply of oxygen to the fire source in the container.

Smoke / heat detectors & fire alarms

For the protection of fire proof containers it is important that an early warning system is installed. DENIOS uses certified multi sensors for this purpose. Smoke and fire detection is quick and reliable and can be installed in conjunction with a siren. The alarm system can be connected to the main alarm system.

Storage Cabinet OptionsStorage Building Options

Page 24: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

4746

The Preferred Solution for Secured, Small Volume Storage of Drums and Totes

DENIOS’ provides business and industry the most complete drum Locker program available. Designed for small volume outdoor storage of drums and IBC Totes, DENIOS’ Locker Program manufactures a variety of models; from secured, basic storage of non-combustible chemicals to more robust designs for hazardous applications, including 2-hour fire rated construction.

The majority of DENIOS Lockers are FM Approved- see individual pages for details.

Sizes and Styles:

Locker capacities from 2-14 drums, 1-2 IBC totes

All units are built to accommodate outdoor placement. Door styles vary and include hinged doors and roll-up doors

Locker and door heights allow added headroom for attachment of mixers or pumps for dispensing / processing

Non-Combustible, fire rated, and / or temperature controlled models available

Common Applications for Lockers

Outdoor storage of small volumes of hazardous chemicals

Rail, marine, truck, and DOT terminals, storing / dispensing lubricants and oils

Parks, turf, and nursery centers for storage of fertilizers and pesticides

Temperature controlled outdoor storage of raw materials

Hazardous waste accumulation centers

Applicable Regulations

DENIOS Lockers meet the federal requirements for spill containment of hazardous liquids as regulated by the EPA (40 CFR).

DENIOS follows NFPA 30 regulations for specification compliance for outdoor placement.

Most Locker designs are FM Approved and / or are constructed with UL approved walls / doors.

Due to local code variance and different enforcement philosophies, DENIOS always recommends checking with the local Authority Having Jurisdiction to verify that a specific configuration will comply with local codes.

Introduction to Chemical Storage Lockers

Locker Program – Overview

K-Series LockersThese light duty, economy Lockers provide for 1, 2, and 4 drum capacities.

Great for secured storage of non-hazardous chemicals.

PK-Series LockersNon- combustible and 2-hour fire rated construction models handle 2, 4, 6, and

8 drum capacities. Non-combustible models FM Approved.

N-Series Lockers Our most complete Drum Locker series, features non-combustible, damage limiting, and 2-hour fire rated construction models,

2-14 drum capacities, and numerous options.

FM Approved. 90 and 150 MPH rated designs.

IBC Tote Lockers Non-combustible, 2-hour fire rated, and special dispensing models highlight these 1-2 tote capacity designs. Numerous options also available.

Most models FM Approved and provide 90 and 150 MPH rated designs.

Specialty Lockers 2-hour, fire rated construction with automatic closing roll-up doors. 2 to 8 drum capacities.

FM Approved. 90 and 150 MPH rated designs.

Full-face opening doors ease material handling in and out of the Locker

Channels for forklift access allow for easy relocationOptional ramp eases loading

and unloading of non-palleted drums

Added height allows for attachment of pumps to vertical drums and shelving

Constructed with 16 gauge steel walls

Compliant spill containment sump sits below galvanized grating

Perfect for storing and handling small quantities of drums / IBC totes

Fire rated Locker modified to have two levels. Used to store small volume containers of flammables.

2-hour Fire Rated IBC Locker with roll-up door. Door includes fuse link and will automatically close in case of fire.

4 drum storage Locker. Design provides added headroom for optional shelving or attaching pumps to drums.

International Fire Code (IFC)

International Building Code (IBC)

Code of Federal Regulations (CFR)

Environmental Protection Act (EPA)

National Fire Protection Assn. (NFPA)

Uniform Fire Code (UFC)

Uniform Building Code (UBC)

Fire Rated designs up to 2-hour, heating systems for Freeze Protected

For your further reference

Hazardous materials storage is regulated by EPA at the federal level by the Code of Federal Regulations (40 CFR).

At the state and local level, Fire Codes such as IFC, UFC, NFPA 30 (Storage and Handling of Flammable Liquids), Building Codes (UBC & IBC) and other requirements specific to State and Local jurisdictions may also apply.

Typical local code issues include: wind load, snow load, seismic zone, fire rating and separation of flammable storage from the nearest building.

Although DENIOS provides numerous standard designs, we also custom engineer Lockers to meet customer requirement.

Page 25: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

4948

Our Solid, light duty Locker

Design provides additional interior height, allowing for vertical drum pumping operations.

Provides secured, weather-proof exterior storage.

Available in 1, 2, 4, and 8 drum models

Steel construction provides strength and durability

66 gallon sump meets EPA and UFC requirements

Walls and doors constructed of 20 gauge steel

Four way forklift access makes relocation easy

Lockable hinged door provides added security and opens wide for easy access to drums / containers

Shelf System for our K-Series Lockers

Self-supporting shelf system rests on grating and provides efficiency and convenience when storing smaller containers

Painted steel frame supports heavy duty galvanized shelves

System designed to fit one, two, and four drum models

Each shelf provides a load capacity of 150 lbs (one drum model) and 200 lbs (2 and 4 drum models)

Standard system includes shelf stand and one shelf. Additional shelves available

Can be easily removed intact should storage requirements change

Ships knock-down; easily bolts together

K-Series Storage Lockers Shelf Package

Full-faced, lockable hinged door provides security and weather protection. Vents for passive ventilation are standard.

59” interior height allows easy access to drum tops for dispensing.

Bottom supports rest directly on grating. Galvanized shelves and uprights make adjustments easy while providing strength to hold up to 200 lbs.

Self supporting system provides stability without having to drill into the Locker.

Model Number

Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

K17-3851 1 / 1 33 33 82 30 30 59 28 61 462 600 66K17-3852 2 / 1 58 33 76 50 30 59 54 61 616 1,200 66K17-3854 4 / 1 58 58 73 55 55 59 28 61 882 2,400 66K17-3856 8 / 2 116 58 73 110 55 59 64 61 1762 4,800 140

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

K-Series Lockers — Shelf Package

Model Number Drum Package

Length Depth Height

Shipping Weight

(lbs)

Load Capacity (lbs)

K17-3858 1 Drum 31 25 55 60 150K17-3859 1 Drum Shelf Adder 30 18 - 15 150K17-3860 2+4 Drum 51 25 55 80 200K17-3861 2+4 Drum Shelf Adder 51 18 - 23 200

Dimensions (in)

K-Series Lockers — Shelf Package

Optional shelving allows for the efficient storage of small containers and tools.

Designs provide for the storage of 1, 2, 4, and 8 drums.

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Page 26: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

5150

Our PK-Series Lockers feature a heavy duty, 11 gauge welded steel construction. Capacities include 2, 4, 6, and 8 drum models. Non-combustible designs are FM Approved.

72” interior headroom allows accessing vertically placed drums for pumping / dispensing

Easily removable, galvanized steel grating

Sump volumes meet EPA and UFC requirements

Lockable hinged doors with inside release

Add shelving for smaller containers

Passive ventilation

Exterior grounding lug

Anchoring point

NFPA 704 placard

Choose between blue, tan, or white painted finish

Our “PK” line of Lockers also are available in 2-hour fire rated construction, allowing for convenient, secured outdoor storage of flammables near your facility.

Constructed with UL – approved 2-hour rated firewall design

Complies with fire rating requirements for storage of flammables within 10 feet of your facility

Drums can be easily accessed with a fork truck or optional ramp

Use multiple Lockers to separate incompatible materials

Secure, Enclosed Outdoor Storage of Flammables with 71” Interior Headroom for Dispensing Equipment.

PK-Series Storage LockersNon-Combustible 2-Hour Fire Rated

Available options:RampInterior light (300W) with fan (350 CFM)Exterior light (500W) with photo eyeShelvesFire Bottle (FE-241)

4 drum storage Locker. Extra headroom for optional shelving or attaching pumps to drums.

All Lockers have wide, full-face opening doors for easy access and pallet loading.

6-drum fire rated Locker utilizing optional shelving package for storage of smaller containers. Price of shelving not included.

4 drum fire rated Locker provides secure, weather-tight enclosure for outdoor dispensing.

Model Number

Drum Capacity per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

P19-1000 2 96 58 88 55 44 71 51 71 1,700 600 65P19-1050 4 96 70 88 55 56 71 51 71 1,900 1,200 97P19-1100 6 118 70 88 77 56 71 73.25 71.5 2,300 2,400 135P19-1150 8 143 70 88 102 56 71 98 71 2,700 4,800 178

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

PK -Series Lockers — 2-Hour Fire Rated

Model Number

Drum Capacity per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

K17-3571 2 96 58 88 66 49 72 51 71 1,700 600 102K17-3575 4 96 70 88 66 62 72 51 71 1,900 1,200 127K17-3578 6 118 70 88 88 62 72 73 71 2,300 2,400 168K17-3580 8 143 70 88 113 62 72 98 71 2,700 4,800 228

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

PK-Series Lockers — Non-Combustible

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Note: Two 13” vent hoods ship unattached but are included in length dimension.

Note: Two 13” vent hoods ship unattached but are included in length dimension.

Locker height allows for shelving, depth (4-drum models and up) provides space for horizontal placement of drums.

Page 27: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

5352

The DENIOS Non-Combustible N-Series Locker Line provides a wide range of storage capacities (2-14 drums) with numerous options.

Durable 11-gauge welded, steel construction

Provides a spill compliant sump, meeting EPA and UFC requirements

FM approved

Lockable, hinged doors with inside release provides added safety

All models come standard with:

- Galvanized grating above a spill compliant sump

- Passive ventilation - Exterior grounding lug - Anchoring point - NFPA 704 placard - Choose between blue, tan,

or white painted finish

Options include:

- Ramp and Shelves - Water Sprinkler - Fire Bottle (FE-241) - Dry Chemical fire suppression system - 1.8kw and 3.6kw electric heater

with R-10 insulation - 14,000 BTU air conditioner

with R-10 insulation - Interior light (300W) with fan (350 CFM) - Exterior light (500W) with photo eye - Fiberglass grating and poly sump liner

for storing acids / caustics

Our fire rated N-Series Lockers provide 2-hour fire rated construction with a variety of options and capacities of 2-14 drums.

N-Series Storage LockersNon-Combustible 2-Hour Fire Rated

Lockers for 2-14 Drum, Non-Combustible Storage Locker.

N-Series Lockers come in

90 MPH and 150 MPHHurricane Rated Designs. Ramp for N-Series Lockers secures to door sill

without effecting door performance.

Model Number

Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

N05-3104 2 / 1 96 58 98 61 49 82 54 80 1,700 1,200 96N05-3109 4 / 1 96 70 98 64 61 82 54 80 1,900 2,400 121N05-3115 6 / 1 118 70 98 86 61 82 54 80 2,400 3,600 162N05-3120 8 / 1 143 70 98 111 61 82 54 80 2,900 4,800 209N05-3130 10 / 2 168 70 98 136 61 82 54 80 3,400 6,000 256N05-3135 12 / 2 193 70 98 161 61 82 54 80 3,800 7,200 304N05-3140 14 / 3 236 70 98 204 61 82 54 80 5,100 8,400 388

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

N-Series / Non-Combustible — 150 mph Construction

Model Number

Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

N05-4104 2 / 1 96 58 98 54 41 81 52 79 3,000 1,200 77N05-4109 4 / 1 96 70 98 54 50 81 52 79 3,400 2,400 99N05-4115 6 / 1 118 71 98 75 50 81 52 79 4,000 3,600 124N05-4120 8 / 1 143 71 98 100 50 81 52 79 4,800 4,800 165N05-4130 10 / 2 168 71 98 125 50 81 52 79 5,600 6,000 205N05-4135 12 / 2 193 71 98 150 50 81 52 79 6,400 7,200 245N05-4140 14 / 3 236 71 98 193 50 81 52 79 7,900 8,400 315

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

N-Series / 2-Hour Fire Rated — 150 mph Construction

Model Number

Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

N05-3004 2 / 1 96 58 98 66 50 82 54 80 1,400 1,200 103N05-3009 4 / 1 96 70 98 66 62 82 54 80 1,600 2,400 128N05-3015 6 / 1 118 70 98 88 62 82 54 80 2,400 3,600 170N05-3020 8 / 1 143 70 98 113 62 82 54 80 2,600 4,800 218N05-3030 10 / 2 168 70 98 138 62 82 54 80 3,300 6,000 267N05-3035 12 / 2 193 70 98 163 62 82 54 80 3,500 7,200 315N05-3040 14 / 3 236 70 98 206 62 82 54 80 4,900 8,400 398

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

N-Series / Non-Combustible — 90 mph Construction

Model Number

Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

N05-4004 2 / 1 96 58 98 56 42 81 52 79 3,000 1,200 77N05-4009 4 / 1 96 70 98 56 52 81 52 79 3,400 2,400 99N05-4015 6 / 1 118 71 98 77 52 81 52 79 4,000 3,600 125N05-4020 8 / 1 143 71 98 102 52 81 52 79 4,800 4,800 165N05-4030 10 / 2 168 71 98 127 52 81 52 79 5,600 6,000 205N05-4035 12 / 2 193 71 98 152 52 81 52 79 6,400 7,200 245N05-4040 14 / 3 236 71 98 195 52 81 52 79 7,900 8,400 315

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

N-Series / 2-Hour Fire Rated — 90 mph Construction

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Note: Two 13” vent hoods ship unattached but are included in length dimension.

Lockers for 2-14 drum, 2-hour fire rated design is constructed with UL Approved firewalls.

Constructed with UL- approved 2-hour rated firewall design

Complies with fire rating requirements for storage of flammables within 10 feet of your facility

Provides a spill compliant sump, meeting EPA and UFC requirements

FM approved

Lockable, hinged doors with inside release provides added safety

14 drum, 2-hour fire rated design features three door sets to ease material handling.

Page 28: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

5554

Model Number

Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

N05-5004 2 / 1 96 58 98 61 49 82 54 80 1,700 1,200 96N05-5009 4 / 1 96 70 98 64 61 82 54 80 1,900 2,400 121N05-5015 6 / 1 118 70 98 86 61 82 54 80 2,400 3,600 162N05-5020 8 / 1 143 70 98 111 61 82 54 80 2,900 4,800 209N05-5030 10 / 2 168 70 98 136 61 82 54 80 3,400 6,000 256N05-5035 12 / 2 193 70 98 161 61 82 54 80 3,800 7,200 304N05-5040 14 / 3 236 70 98 204 61 82 54 80 5,100 8,400 388

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

N-Series Lockers — Explosion Relief Panels

These N-Series Lockers feature explosion relief panels built into the rear of each Locker- diverting destructive forces away from personnel and facilities in the event of an ignition / explosion of the stored drums.

Durable 11-gauge welded, steel construction

Provides a spill compliant sump, meeting EPA and UFC requirements

FM approved

Lockable, hinged doors with inside release provides added safety

2-hour fire rated models also available. Contact factory for details

All models come standard with:

- Galvanized grating above a spill compliant sump

- Passive ventilation - Exterior grounding lug - Anchoring point - NFPA 704 placard - Choose between blue, tan, or white

painted finish

N-Series Storage LockersExplosion Relief Panels

IBC Storage LockersNon-Combustible

Model Number

IBC Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

K17-3583 1 / 1 99 70 100 69 62 61 54 80 2,300 5,000 559K17-3585 2 / 1 153 70 88 123 62 61 54 80 3,100 10,000 501

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

IBC Lockers / Non-Combustible — 90 mph windload

P19-2050 1 / 1 99 70 100 87 61 61 54 80 2,300 5,000 506P19-2055 2 / 1 153 70 88 121 61 64 54 80 2,900 10,000 501

IBC Lockers / Non-Combustible — 150 mph windload

P19-2250 1 / 1 99 70 100 67 61 61 54 80 2,300 5,000 560P19-2255 2 / 1 153 70 88 121 61 64 54 80 2,900 10,000 501

IBC Lockers / Non-Combustible — 150 mph / DLC panels windload

Rear panels provide an exit for explosive force- diverting the blast’s destructive force away from personnel / facilities.

In case of an explosion, relief panel detaches from the Locker, diverting destructive forces away, protecting the integrity of the Locker and preventing any explosion caused shrapnel.

Safety cables prevent relief panels from causing damage.

2-IBC tote Locker’s double, full face opening doors allow easy access to both totes.

IBC tote Locker

Note: Two 13” vent hoods ship unattached but are included in length dimension.

N-Series Lockers come in

90 MPH and 150 MPHHurricane Rated Designs.

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

N-Series Lockers come in

90 MPH and 150 MPHHurricane Rated Designs.

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Non-Combustible Designs provide secure, spill contained storage for 1-2 IBC Totes.

Provides a spill compliant sump, meeting EPA and UFC requirements

Designs are FM approved

Lockable hinged doors provide full face opening, easing material handling in and out of the Locker

Full-face opening eases access for material handling

Built to carry higher loads from IBCs

Models P19-2250 and P19-2255 include damage limiting construction (DLC) panels

Options include:

- Dry chemical fire suppression system - 1.8 or 3.6 kw electric heater with

R-10 insulation - 14,000 BTU air conditioner with

R-10 insulation - Exterior light (500 W) with photo eye - Fiberglass grating and poly sump

liner for storing acids / caustics

Page 29: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

5756

Options include:

- Ramp and shelves - Fire bottle (FE-241) - Dry chemical fire suppression system - 1.8 or 3.6kw electric heater with

R-10 insulation - 14,000 BTU air conditioner with

R-10 insulation - Interior light (300W) with fan (350 CFM) - Exterior light (500W) with photo eye - Fiberglass grating and poly sump liner

for storing acids / caustics

4 Drum Locker with optional mechanical ventilation and dry chemical fire suppression (options sold separately).

Models come standard with:

- Galvanized grating above a spill compliant sump

- Passive ventilation - Exterior grounding lug - Anchoring point - NFPA 704 placard - Choose between blue, tan,

or white painted finish

IBC Storage Lockers2-Hour Fire Rated

Specialty Storage Lockers2-Hour Fire Rated

Lockers for 1-2 IBC, 2-hour fire rated design is constructed with UL Approved firewalls. Roll-up doors includes fuse link and will automatically close in case of fire.

Single or double IBC Locker with hinged door designs to ease material handling / entry into the Locker.

2-8 Drum Locker shown with optional white color and dry chemical fire suppression (sold separately).

Model Number

IBC Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

P19-1250 1 / 1 99 74 100 58 56 60 55 60 3,900 5,000 438P19-1255 1 / 1 99 81 117 58 56 60 53 60 3,900 5,000 438P19-1300 2 / 1 153 70 88 112 56 60 108 60 5,200 10,000 423P19-1305 2 / 1 153 81 102 112 56 60 108 60 5,200 10,000 423

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

IBC Lockers / 2-Hour Fire Rated — 90 mph windload Model Number

Drum Capacity / No. Doors per Cabinet Length Depth Height Length Depth Height Length Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

P19-1005 2 / 1 96 58 105 56 44 81 51 71 3,000 1,200 76P19-1055 4 / 1 96 81 105 55 56 81 51 71 3,400 2,400 98P19-1105 6 / 1 118 81 105 77 57 81 73 71 4,100 3,600 136P19-1155 8 / 1 143 81 105 102 57 81 98 71 4,800 4,800 180

Exterior Dimensions (ft) Bay Dimensions (in) Door Opening (in)

Specialty Lockers / 2-Hour Fire Rated — 90 mph Hurricane Rated Designs

P19-2150 1 / 1 99 81 117 56 55 71 53 60 3,900 5,000 438P19-2155 2 / 1 153 81 102 112 56 71 108 60 5,200 10,000 423

IBC Lockers / 2-Hour Fire Rated — 150 mph windloadP19-2105 2 / 1 96 68 105 53 43 81 51 71 3,000 1,200 72P19-2110 4 / 1 96 81 105 53 55 81 51 71 3,400 2,400 93P19-2115 6 / 1 118 81 105 75 55 81 73 71 4,100 3,600 130P19-2120 8 / 1 143 81 105 100 55 81 98 71 4,800 4,800 173

Specialty Lockers / 2-Hour Fire Rated — 150 mph Hurricane Rated Designs

N-Series Lockers come in

90 MPH and 150 MPHHurricane Rated Designs.

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Note: Two 13” vent hoods ship unattached but are included in length dimension.

N-Series Lockers come in

90 MPH and 150 MPHHurricane Rated Designs.

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Note: Two 13” vent hoods ship unattached but are included in length dimension.

Added Safety for Totes Storing Flammables

These 2-hour fire rated Tote Lockers designs provide for secured, convenient outdoor placement of 1-2 Totes near your facility.

Sumps are sized to provide compliant spill volumes for 350-gallon totes.

Roll-up door models FM Approved.

Constructed with UL- approved 2-hour rated firewall design

Complies with fire rating requirements for storage of flammables within 10 feet of your facility

Built to carry the higher loads from IBC’s

Sump volumes meet EPA and UFC requirements

Lockable hinged and roll-up doors provide full face opening, easing material handling in and out of the Locker

Secured Storage for Drums Storing Flammables

DENIOS’ Specialty 2-Hour Fire Rated Lockers come with Automatic Closing Roll-Up Doors, providing the highest level of convenience and safety.

Doors are UL Labeled and Rated for 1-1/2 hours in accordance with FM Standards and NFPA regulations.

Lockers have the same extended height allowing ample room for pumping and other activities

Roll-up door has fuse link automatic closing in case of fire

Page 30: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

5958

Like our Cabinets and Buildings, DENIOS can custom engineer our Lockers to meet the requirements of just about any application.

Customized Lockers have included heated and cooled models, custom door sets, fixed shelves, as well as designs for specialized dispensing.

In addition, DENIOS also engineers it’s Lockers for process heating applications, utilizing either steam or electric heat and achieving temperatures up to 300°F.

Standard options (see adjoining page) are available by Locker Series.

Custom Engineered Storage Lockers

Fire rated Locker with mechanical ventilation.

Optional double roll-up doors allow for easier handling and processing of totes.

Double tote Locker with fire rated construction and mechanical ventilation.

Optional fixed shelf provides for storage of small packages of flammables. Automatic fire doors remain open for access to packages and will close in case of fire in or outside of the Locker.

Storage Locker Options

K-Series Lockers

All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard.

There are no options available.

N-Series Lockers

All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish.

Options include ramp and shelves, water sprinkler, fire bottle (FE-241), dry chemical fire suppression system, 1.8kw and 3.6kw electric heater with R-10 insulation, 14,000 BTU air conditioner with R-10 insulation, interior light (300W) with fan (350 CFM), exterior light (500W) with photo eye and fiberglass grating and poly sump liner for storing acids/caustics.

Specialty Lockers

All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish.

Options include ramp and shelves, water sprinkler, fire bottle (FE-241), dry chemical fire suppression system, 1.8 or 3.6kw electric heater with R-10 insulation, 14,000 BTU air conditioner with R-10 insulation, interior light (300W) with fan (350 CFM), exterior light (500W) with photo eye and fiberglass grating and poly sump liner for storing acids/caustics.

PK-Series Lockers

All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish.

Options include ramp, interior light (300W) with fan (350 CFM), exterior light (500W) with photo eye, shelves and fire Bottle (FE-241).

IBC Lockers

All models come standard with galvanized grating above a spill compliant sump, passive ventilation, exterior grounding lug, anchoring point and NFPA 704 placard. Choose between blue, tan, or white painted finish.

Options include dry chemical fire suppression system, 1.8 or 3.6kw electric heater with R-10 insulation, 14,000 BTU air conditioner with R-10 insulation, exterior light (500W) with photo eye and fiberglass grating and poly sump liner for storing acids/caustics.

Page 31: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

6160

HazMat Station for 2 Drums.

HazMat Station with steel sump and grating for 4 drums.

Flexible Design Allows for Shelving and Dispensing Options

DENIOS HazMat Stations are designed to provide a safe, secure environment for storage, dispensing, and mixing of small volumes of chemicals. Featuring a weather-proof, lockable hinged lid and doors, they provide personnel easy access to the tops of drums and other stored chemicals for dispensing and mixing operations. When dispensing, any spills or drips are contained by a built-in, compliant spill sump.

Optional shelving packages provide efficient, secured exterior storage for smaller containers.

Add drum cradles to create a mixing and dispensing station which provides compliant spill containment.

Keeps Drums Secure and Accessible for Storage or Dispensing

Enclosed HazMat Stations are complete with lockable, hinged lid and doors for storing hazardous materials securely outdoors.

HazMat Stations for 2 and 4 Drums

For access to tops of drums, lid lifts easily and is supported by heavy duty gas cylinders

Solidly welded steel construction for extended life

Sump welds are 100% inspected with a low-viscous test to insure leak-tightness

66-Gallon sump volumes meet EPA and UFC requirements

Passive ventilation is standard

Coated with a durable, corrosion and weather resistant finish

Removable galvanized steel grating for easy cleanup

Four-way forkliftable

Enclosed HazMat Stations

Model Number

Capacity per Cabinet

(55 gal drums) Length Depth Height

Shipping Weight

(lbs)

Load Capacity per Bay

(lbs)

Sump Volume (gal)

K17-3502 2 54 34 55 425 1,200 66

K17-3503 4 56 56 55 585 2,400 66

Exterior Dimensions (ft)

HazMat Station

Double tote Locker with fire rated construction and heating.

4 drum HazMat Station with half width shelf.

4 drum HazMat Station with half width shelf and single drum cradle.

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Page 32: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

6362

In cases of catastrophic spills or sprinkler releases, containing the spill to a single room or area can limit the costs associated with clean-up or facility damage.

DENIOS Automatic Doorway Spill Barriers provide the protection to contain those large spills by closing off any doorway or opening in the affected room at the first sign of flowing liquids.

Federal Regulations along with Local Jurisdictions require that sprinkler water in combination with regulated or hazardous materials be prevented from being released into the environment via sewers, streams, or ground contamination. When a release occurs, fines and clean-up costs can be staggering.

NFPA-30 9.13.3

Curbs, scuppers, special drains, or other suitable means shall be provided to prevent the flow of liquids under emergency conditions into adjacent building areas.

IFC-2704.2.2.3 (2009)

Secondary containment for indoor storage areas shall be designed to contain a spill from the largest vessel plus the design flow volume of fire-protection water calculated to discharge from the fire-extinguishing system over the minimum required system design area or area of the room… for a period of 20 minutes.

OSHA 1910.106 (e) (3) (iv) (a)

Emergency drainage systems shall be provided to direct flammable or combustible liquid leakage and fire protection water to a safe location. This may require curbs, scuppers, or special drainage systems to control the spread of fire.

OSHA 1910.106 (d) (4) (i)

Openings to other rooms or buildings shall be provided with non-combustible liquid-tight raised sills or ramps at least 4” in height.

Fully automatic operation ensures barrier will close even in cases of power loss

Features of the Automatic Doorway Spill Barrier Include:

Solid welded stainless steel construction

Self-contained one piece system design

Fully automatic operation, no external power source or factory compressed air required

Easy installation in existing doorways; stores horizontally in the floor, permitting unobstructed vehicular and personnel traffic until a spill occurs

While laying flat, Barrier provides up to 6.5 tons axle weight capacity

Designed to fit in doorways between 3 and 16 feet, with barrier heights of 12 to 24 inches

Automatic Doorway Spill Barriers

Barriers prevent spills from reaching storm drains or contaminating ground water

When not deployed, Barrier door stores flat in floor, eliminating the need for ramps or berms. Automatically closes with introduction of liquid in the built-in collection sump, creating a liquid tight seal and containing the spill in the room where it originated

Operation – Flow of liquid triggers the Barrier to automatically shut

Automatic Doorway Spill Barriers are often utilized as containment equipment for Flammables Storage Rooms

Model Number

Nominal Width of Door (ft)

Opening Span (In)

Sealed Width

(In)

R11-0312 3 36 40R11-0412 4 48 52R11-0612 6 72 76R11-0812 8 96 100R11-1012 10 120 124R11-1212 12 144 148R11-1412 14 168 172R11-1612 16 192 196

Liquid Retention Height — 12-inch

Model Number

Nominal Width of Door (ft)

Opening Span (In)

Sealed Width

(In)

R11-0318 3 36 40R11-0418 4 48 52R11-0618 6 72 76R11-0818 8 96 100R11-1018 10 120 124R11-1218 12 144 148R11-1418 14 168 172R11-1618 16 192 196

Liquid Retention Height — 18-inch

Model Number

Nominal Width of Door (ft)

Opening Span (In)

Sealed Width

(In)

R11-0324 3 36 40R11-0424 4 48 52R11-0624 6 72 76R11-0824 8 96 100R11-1024 10 120 124R11-1224 12 144 148R11-1424 14 168 172R11-1624 16 192 196

Liquid Retention Height — 24-inch

Combine with curbing to effectively cut off and contain liquid storage areas.

Page 33: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

6564

DENIOS’ Exclusive HazBerm creates large, modular containment areas within facilities – a more efficient alternative to conventional berms and curbs

Patent-pending modular design allows for custom sizing for each application

Polymer concrete segments are highly chemical and fire resistant

Use in combination with Doorway Spill Barriers to allow easy transport in and out of the berm area

Systems are easily supplied and installed

Easily relocated or altered as needs change – no need to jack-hammer and replace the existing system

Available in tan or black

Does not require floor footers, forms, or on-site concrete pouring

HazBermFM Approved Flood Barrier

The HazBerm can be placed around processing equipment to contain potential leaks and spills

The HazBerm is available in 1 and 3 foot segments as well as the 1 foot corner and reverse corner segments. (Reverse corner not shown. Hardware included, but not shown.)

Segments seal together to form a virtually leak-proof barrier

Combine with manual or automatic Doorway Spill Barriers to allow easy access to stored chemicals

HazBerm is both chemical and fire resistant

DENIOS announces our new FM Approved Automatic Doorway Flood Barrier System (FM Approvals Class 2510). This barrier keeps floodwaters out of your facilities by providing a flood “wall” at your doorways.

Provides all the durable construction and operational characteristics of our doorway spill barrier but is designed specifically for floodwaters.

The Doorway Flood Barrier installs easily in existing doorways and stores horizontally in the floor, permitting normal vehicular and personnel traffic, until a flood occurs. With the first flow of water the Barrier automatically closes. No additional ramps or berms are needed.

In addition, the DENIOS Automatic Doorway Flood Barrier provides:

Door heights of 12, 18, and 24 inches. Widths from 3 to 12 feet.

Flexible design allows installation either inside or outside exterior doors.

In open position, Flood Barrier lays flat in floor, allowing normal traffic.

Doorway Flood Barrier in closed position.

Model Number Description

Length Depth Height Length Depth Height

Shipping Weight

(lbs)

R05-0230 3’ Straight 36 4 18 - - - 90R05-0210 1’ Straight 12 4 18 - - - 29R05-0290 1’ Corner 12 4 18 8 4 18 44R05-0292 1’ Reverse Corner 12 4 18 8 4 18 44

Exterior Dimensions (in) Interior Dimensions (in)

HazBerm Segments — Tan

R05-0231 3’ Straight 36 4 18 - - - 90R05-0211 1’ Straight 12 4 18 - - - 29R05-0291 1’ Corner 12 4 18 8 4 18 44R05-0293 1’ Reverse Corner 12 4 18 8 4 18 44

HazBerm Segments — Black

Model Number

Nominal Width of Door (ft)

Opening Span (In)

Sealed Width

(In)

R11-0312 3 36 40R11-0412 4 48 52R11-0612 6 72 76R11-0812 8 96 100R11-1012 10 120 124R11-1212 12 144 148

Liquid Retention Height — 12-inch

Model Number

Nominal Width of Door (ft)

Opening Span (In)

Sealed Width

(In)

R11-0318 3 36 40R11-0418 4 48 52R11-0618 6 72 76R11-0818 8 96 100R11-1018 10 120 124R11-1218 12 144 148

Liquid Retention Height — 18-inch

Model Number

Nominal Width of Door (ft)

Opening Span (In)

Sealed Width

(In)

R11-0324 3 36 40R11-0424 4 48 52R11-0624 6 72 76R11-0824 8 96 100R11-1024 10 120 124R11-1224 12 144 148

Liquid Retention Height — 24-inch

DENIOS-Leading Supplier of FM Approved Chemical Containment Products.

Page 34: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

6766

100

73

Temp, °F

Flammable Liquide Classification

IA IB IC

The following pages are intended as a guide to the vast array of regulations concerning the storage and handling of flammable and combustible chemicals. As regulations and their interpretations change over time, your local Authority Having Jurisdiction (AHJ) should always be consulted when considering storing hazardous materials inside or outside your facility.

These next few paragraphs will provide brief insight to help you understand some of the fundamental parts of the Code of Federal Regulations, Title 29, Parts 1900 to 1910.999, and the Occupational Health and Safety Act of 1970 regarding the external storage of flammable liquids. In addition, data has been taken from the National Fire Protection Association’s NFPA 30 “Flammable and Combustible Liquids Code”, the 2010 edition of the “International Building Code” and the 2009 edition of the “International Fire Code.”

Best regards

Grant Hart

Grant HartBusiness Development ManagerDENIOS, Inc.

The Basics for the Handling and Storage of Flammable Chemicals –Definitions

Chemical or Fuel °C °F

Acetone 465 869Benzene 560 1,040

Diethyl Ether 160 320Ethylene 490 914

Ethyl Alcohol 365 689Fuel Oil No. 2 256 494

Gasoline 280 536Kerosene 210 410

Isopropyl Alcohol 399 750Methyl Alcohol 385 725

Propane 480 896Toluene 480 896Xylene 463 867

Temperature

Auto-Ignition Temperatures for Some Common Chemicals or Fuels

Boiling Point

The temperature at which the vapor pressure of a liquid equals the surrounding atmospheric pressure.

Flash Point

The minimum temperature of a liquid at which sufficient vapor is given off to form an ignitable mixture with air near the surface of the liquid.

Flammable Liquid

Any liquid that has a flash point below 100° F (37.8° C).

Flammable liquids are classified as Class I liquids with further sub-classification per the following and as shown in Figure 1:

Class IA – Any liquid that has a flash point below 73° F (22.8° C) and a boiling point below 100° F (37.8° C). Examples of this class are Ethyl Ether and Pentane.

Class IB – Any liquid that has a flash point below 73° F (22.8° C) and a boiling point at or above 100° F (37.8° C). Examples of this class are Gasoline and MEK.

Class IC – Any liquid that has a flash point at or above 73° F (22.8° C) but below 100° F (37.8° C). Examples of this class are Xylene and Turpentine.

Classification of Flammable Liquids

Indicates liquid boiling point

Indicates liquid flash point

National / International Authorities

International Fire Code (IFC)

International Building Code (IBC)

Code of Federal Regulations (CFR)

Environmental Protection Act (EPA)

National Fire Protection Assn. (NFPA)

Uniform Fire Code (UFC)

Uniform Building Code (UBC)

It is critical to understand the uniform system of defining and classifying flammable and combustible liquids and why it is important to take the necessary precautions to provide the correct methods of storage.

Authority Having Jurisdiction (AHJ)

An organization, office or individual responsible for enforcing code requirements or standards.

Auto-Ignition Temperature

The minimum temperature at or above which a material will spontaneously ignite (catch fire) without an external spark or flame. See following Table 1:

Combustible Liquid

Any liquid that has a flash point at or above 100° F (37.8° C).

Combustible liquids are classified per the following and as shown in Figure 2:

Class II – Any liquid that has a flash point at or above 100° F (37.8° C) and below 140° F (60° C). Examples of this class are Kerosene and Oil-Based paints.

Class III – Any liquid that has a flash point above 140° F (60° C)

1) Class IIIA Liquid – Any liquid that has a flash point at or above 140° F (60° C), but below 200° F (93° C). An example of this is Mineral Spirits.

2) Class IIIB Liquid – Any liquid that has a flash point at or above 200° F (93° C). Examples of this class are Hydraulic Brake / Transmission fluids and lube oils.

Flammable Range (Explosive Range)

The range of a concentration of a gas or vapor that will burn (or explode) if an ignition source is introduced.

MAQ (Maximum Allowable Quantity)

The maximum quantity of flammable or combustible liquids allowed to be stored in a given occupancy. The MAQ varies per the occupancy class and the fire protection systems available. But in general it begins at 120 gallons of liquid.

Control AreaDefined in NFPA 30, Section 9.7 and generally defined as follows:

1. A building or portion of a building within which flammable and combustible liquids are allowed to be stored, dispensed and used or handled in quantities of liquids that do not exceed those listed in NFPA 30 Table 9.6.1 or Table 9.6.2 for all liquid Classes I, II and III.

2. An area separated from each other by fire barriers per NFPA Table 9.7.2.

4 drum Locker with fire rated construction for storage of flammable liquid chemicals.

“H” Occupancy

Occupancy where the quantity of flammable liquid or other hazardous material stored exceeds the MAQ. Storing quantities above MAQ generally makes the occupancy a “hazardous occupancy” (H1-H5).

Most DENIOS Lockers, Cabinets and “walk in” style Buildings fall into these two categories:

H-2 – Class I, II or IIIA flammable or combustible liquids which are used or stored in NORMALLY OPEN containers or systems, or in closed containers pressured at more than 15 psig.

H-3 – Class I, II or IIIA flammable or combustible liquids which are used or stored in NORMALLY CLOSED containers or systems, or in closed containers pressured at 15 psig or less.

Combustible Classification

Temp, °F

Flash Point

100

140

200

II IIIA IIIB

Page 35: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

6968

Fire Rating (hrs) Distance (ft)

4 02 100 30

Minimum Separation Distance from Storage Structure to Property Line

or other Important Building

Storage of Flammable Liquids in Quantities exceeding 120 gal (460L)

The storing of Class I, II and IIIA liquids in individual containers shall meet all the applicable requirements of NFPA 30.

Material must be separated from the rest of the occupancy either by distance or by fire rated walls. DENIOS Lockers, Cabinets and “walk in” style Buildings are designed for this purpose.

Table 2 adjacent is designed to provide general guidance as to separation distances relative to required fire ratings.

Storage of Flammable Liquids

2 Hour Fire Rated Locker for two IBC Totes with mechanical ventilation system to remove flammable vapors.

Storage of flammable liquids in Chemical Storage Structures inside an existing building

When flammable or combustible liquids are stored in a chemical storage structure that is less than 500 ft2 and is located inside of an existing structure, the chemical storage structure is classified as a Liquid Storage Room and must meet the requirements prescribed.

Ventilation

Chemical storage structures used for storing combustible and flammable liquids should be ventilated. The ventilation method can be either passive (natural) or mechanical (forced).

In most cases air should be drawn from a location within 12-18” of the floor as the majority of flammable liquids give off vapors that are heavier than air.

Deflagration control

Where flammable liquids are dispensed, deflagration panels or control should be provided. The exterior wall containing the panels should be a minimum of 30 feet from another building and the area adjacent to the panels should be kept clear of pedestrian traffic for 30 feet as well.

Explosion prevention systems can be provided which include LEL detectors, multiple fans and associated controls to maintain the vapor level at or below 25% of the Lower Explosive Limit (LEL).

Contact Us:For questions about any of your hazardous chemicals storage or processing needs, contact us at l 866-384-4889 or at l [email protected]

Chemical Spill Containment Requirements

All DENIOS Cabinets, Buildings, and Lockers provide compliant secondary containment sumps below a grated surface.

Secondary Containment

Containment is described in the Fire Code, Flammable Liquids Code and the Code of Federal Regulations (CFR). In general the capacity of the containment must be 10% of the aggregate liquid volume stored or the volume of the largest container stored whichever is larger. Where the storage is indoors and a sprinkler system is in place, local jurisdictions and third party certifiers may have more stringent requirements.

Storage of Flammable Liquids in Quantities not exceeding 120 gal (460L)

For this application, a flammable liquids storage cabinet as approved or listed by a recognized third party agency or constructed per NFPA 30 will suffice. The Local Authority Having Jurisdiction should be consulted regarding the number of cabinets allowed per control area (see definition above).

DENIOS’ HAZMATTER: Typically, flammable liquids storage cabinets are designed to have a sump or spill containment volume of 5 gallons which is based upon storage of typical containers having a volume of 5 gallons or less. However, some of these cabinets are designed to store (2) 55 gallon drums (still within the 120 gallon limit) and DENIOS believes that these cabinets should be compliant under EPA and UFC regulations. Therefore, DENIOS offers a Flammable Cabinet Sump that can be added to the Flammable Cabinets bringing the complete system into EPA and UFC compliance. Make sure to consult your local Authority Having Jurisdiction (AHJ).

Flammable Cabinet sump provides added capacity bringing the system into spill compliance.

Page 36: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

7170

Controlling Storage Temperatures Key

Organic Peroxides present special challenges for storage and handling as they are temperature sensitive and can combust spontaneously if they reach certain temperatures unique to each material.

Self Accelerating Decomposition Temperature

Organic Peroxides decompose at various temperatures giving off heat that can cause or contribute to a fire. This temperature is called Self Accelerating Decomposition Temperature, or SADT, and can be anywhere between -10 to 200C depending upon the material.

Control TemperatureAnother important temperature is the CT or Control Temperature. This is the temperature at which the material can be stored or transported over a long periods of time. This temperature varies between 0 and 20 C less than the SADT depending upon the SADT.

CT=SADT – 20° C if SADT<20°C

CT=SADT – 15°C if SADT >20° C but <35°C

CT=SADT – 10° C if SADT>35° C but <50°C

IF SADT >50°C then there is no CT.

The CT can also be thought of as the alarm temperature when storing the given material.

Storage of Organic Peroxides

Redundant cooling system ensures temperature stability should primary system fail.

Since it is well below the SADT it may be exceeded for short time periods due to maintenance or until alternative cooling methods are available. Still another temperature may come in to play. That is the recommended storage temperature from the manufacturer of the material. This may be even lower than the CT to prevent the material from degrading, decreasing its usefulness.

Thus the key to managing organic peroxides is temperature. If they are maintained at the appropriate temperature in accordance with the manufacturer’s instructions, they can be handled and stored safely.

Organic Peroxides by Definition

Organic Peroxides are divided into five classes by NFPA 400 Chapter 14 for storage, fire fighting and safety reasons.

Class I is the most dangerous class of Organic Peroxides and describes those materials that present a hazard of deflagration through rapid explosive decomposition. Such materials are safe only under strictly controlled temperatures. Dibenzoyl peroxide 98% is one such material.

Class II formulations present a fire hazard similar to Class I flammable liquids such as acetone or toluene.

Class 1 Organic Peroxide Storage Enclosures can require deflagration panels due to the explosive hazards of the material stored.

Class III formulations burn rapidly and present a moderate reactivity hazard. They are similar to combustible liquids such as #2 fuel oil.

Class IV describes those formulations that burn in a manner similar to ordinary combustibles. These fires are easily controlled.

Class V materials burn with less intensity than ordinary combustibles and do not present a severe fire hazard.

Proper Storage of Organic Peroxides

Storage areas for organic peroxides must also be separated from other chemicals including flammables, oxidizers, acids and alkalis by a minimum of 25 feet or a liquid tight one hour fire barrier. Class I (see definitions below) peroxides provide extra challenges as they are considered explosive. Deflagration panels and special building reinforcement are called for when storing these materials. Areas where organic peroxides are stored should be electrically classified as CL I Div 1 or Div 2 as designated by NFPA 400. In addition controls on the refrigeration system should include over temperature alarms (usually set at the Control Temperature) and a smoke or heat detector to notify the appropriate response of a problem in the storage area. Redundant temperature control equipment or approved alternate means should be available in the event of equipment failure. Standby or emergency power should also be considered per NFPA 400.

Page 37: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

7372

Third Party ApprovalsWhat they are and why they are important. Setting the record straight.

with the standards and the ability of the building to withstand a specific wind which is especially important in coastal areas of the US. The standard further evaluates the integrity of fire rated walls and ceiling and certifies the stated containment sump capacity. Contrary to popular opinion, UL (Underwriters Laboratories) does not have a standard for these buildings, so no manufacturer can use the “UL listed” moniker with reference to their buildings. A FM approved building should be labeled as such by the manufacturer. The text of the approval document prescribes what must be on

DENIOS’ FM Approved fire rated Cabinet. DENIOS is presently the only manufacturer with FM Approved Cabinets.

Setting a standard for quality, performance, and construction

Third party approvals for Hazardous Material Buildings have been around since 1991 in the form of FM class 6049. FM began approving hazardous material storage buildings with the first edition of CLASS 6049 in that year. This FM “standard” has remained the defacto standard in the US, unchallenged since that time. Manufacturers that receive FM approval have submitted their designs to a third party and then to FM for review in accordance with the standard. This includes reviewing the structural integrity including floor and snow loads in accordance

the label. This includes place of manufacture, model no., design floor, wind and snow loads, and if applicable, the fire rating of the walls. It also includes whether the building is constructed with damage limiting construction (DLC) also known as deflagration panels, and the electrical classification and temperature classification of any and all electrical equipment installed on the building.

Other drum / IBC storage enclosures approved by FM include modular Buildings.

It is important to note that, even though a manufacturer has multiple items in their approval listing, there may be variations of those products that cannot be labeled as “approved”. This is because the approval listing contains specific construction parameters and characteristics that may or may not be available in a particular model series or combination of accessories.

A third party approval is important because it sets a standard of consistent quality, performance, and construction that is guaranteed by the fact that the building carries the approval. Further, in this case of FM, periodic follow up inspections of the approved company’s manufacturing site(s) are conducted by FM engineers to assure that the approved products are being manufactured in the same manner as was initially examined. Repeated violations can result in the withdrawal of the approval.

While the third party approval certifies a level of engineering, quality and construction, it does not certify a fitness for a specific use nor placement in a specific location. Suitability for use and location are best determined in consultation with your local authority having jurisdiction.

While significant, the approval should be considered a minimum acceptable standard as many manufacturers go above and beyond that required for the approval. At the same time, all FM approved manufacturers may not be equal. While the FM approved moniker denotes a specific level of manufacture for basic standard buildings, the manufacturer’s expertise in building the actual requirements dictated by the application should also be taken into account when evaluating a particular project.

For instance, experience in building heated enclosures with specific heating mediums i.e. steam, electric or oil should be evaluated if

these characteristics are requirements of the project as they are not a part of the FM approval process. Further, experience in cooled or refrigerated units should be evaluated if these features are needed in the scope of the contemplated project. These characteristics are also not contemplated by the FM Approval Process.

A 6-drum, FM Approved, non-combustible Locker Design

Page 38: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

7574

An extra bonus in selection and information 24 hours a day...

The DENIOS web site is open all hours. Comprehensive, informative and now with even greater choices.

Take a look at our site and bookmark the page as a favorite in your browser.

Check back often! We’re constantly adding new products and information to the site. Stay updated with the latest innovations in chemical storage and spill containment at denios-us.com.

Easy-to-use search engines: You’ll always find what you’re looking for!

Place an order whenever you want: Open twenty-four hours a day!

Easy to navigate site highlights the most innovative chemical storage products!

Success stories, technical brochures and much more!

Presentation of innovative developments, including product videos!

Info pages with extracts from current regulations!

Just click away!

To view our full product catalogue please visit www.denios-us.com

www.denios-us.com

Besides our project business we also offer a wide range of standard products...

Page 39: Hazardous Waste Storage - Flammable Storage - Chemical Storage | DENIOS, Inc., | U.S. Division

76 The env i ronment ‘s par tner

DENIOS, Inc.

1152 Industrial Blvd.

Louisville, KY 40219

Phone: 502-933-7272 or 866-384-4889

Fax: 502-933-1560

E-Mail: [email protected]

www.denios-us.com

The DENIOS VisionDENIOS is the worldwide leader in hazardous materials

storage, industrial environmental protection, and workplace

health and safety. Our highly motivated and skilled team is

constantly searching for new ideas and creative innovations,

making a positive impact in shaping the future. We provide

customer benefits through exceptional product quality,

prompt delivery and outstanding customer support and

communication.

DENIOS pledges to be a confidence inspiring project partner

and reliable problem solver for all environmental protection

and workplace safety applications.

We want to make sure our catalog reaches the right people at the right address.

If your address is incorrect, please call us at 800-216-7776 and we’ll fix it immediately. And if you don’t wish to receive the catalog, please don’t throw it away- pass it along to a co-worker who deals with industrial chemicals, safety, or maintenance.

Thank you!

EngineeredProducts