Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the
device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance
Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report
may not in NVLAP accreditation scope and was noted.
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above
version 7.0.
IES LM-79-08 MEASUREMENT AND TEST REPORT
Test Model: HBRE100-4000
Report Type: Electrical and Photometric tests including: Luminous Flux,
Power Factor, Chromaticity, Luminous Intensity
Distribution, THD
Test Engineer: Bill Xiong Hill Liu
Report Number: R2DG170711050-10
Test Date: 2017-07-13 to 2017-07-14
Report Date: 2017-07-17
Reviewed By: Daniel Duan /EE Manager
Test Facility: Test facility was located at No.69, Pulongcun, Puxinhu Industry
Area, Tangxia, Dongguan, Guangdong, China.
Prepared By:
Bay Area Compliance Laboratories Corp. (Shenzhen)
6/F., West Wing, Third Phase of Wanli Industrial Building,
Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.
Tel: +86-755-33320018
Fax: +86-755-33320008
Accreditation: The NVLAP Lab Code is 200707-0.
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 2 of 15
1. Product Description
General Information:
One sample was received on 2017-07-11.
Model Tested:
Manufacturer:
Product Designation:
Burning Time Before Test:
Driver Model:
Rated Values:
Rated Voltage/Frequency:
Rated Power:
Nominal CCT:
Nominal Lumen Output:
HBREL100-4000
INTEGRATECH
LED High Bay Light
0hour(For New Products)
ELG-100-48A
100-240 V AC 50/60Hz
100 W
4000K
14106Im
2. Standards Used
IES LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products
ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting
IES TM-30-15: IES Method for Evaluating Light Source Color Rendition (This method is not in NVLAP
accreditation scope)
3. Description of Test Equipment
Device Manufacture Model No Serial No Test Range Calibration
date
Calibration due
date
1.5m temperature
integrating sphere SENSING SPR-600 S09008 25~50°C 2017-03-09 2018-03-09
High-precision
rapid spectral
analysis system
EVERFINE HAAS-2000 M112048CA136
1125 380-780nm 2017-07-07 2018-07-07
Digital power
meter YOKOGAWA WT310 13398 N/A 2016-12-05 2017-12-05
Programmable
Precision DC
Power Supply
ITECH IT6154 0061 0417 6471
0010 19 0~32V 2017-03-03 2018-03-03
thermometer SENSING NA NA 25、50°C 2017-03-09 2018-03-09
Standard Light
Source SENSING NA LSD090808 N/A 2016-12-05 2017-12-05
Precision
frequency power
supply
ALL Power APW-105N 970613 220V±10%
50Hz 2017-03-03 2018-03-03
AC POWER
SUPPLY EVERFINE VPS1030 PWM 1012017
0-150V, 0-
300V2017-03-03 2018-03-03
Digital CC&CV
DC Power Supply EVERFINE WY12010 1009009 30V/5A 2017-03-03 2018-03-03
Digital power
meter YOKOGAWA WT-210 91KB35700
15/30/60/150/30
0/600 V 2017-03-03 2018-03-03
full-field speed
goniophotometer EVERFINE GO-R5000
YG108492N101
20001
1600mm,3000
W/10A 2017-03-09 2018-03-09
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 3 of 15
Device Manufacture Model No Serial No Test Range Calibration
date
Calibration due
date
Wireless Remote
Sensor N/A 433MHz N/A
0°C~50°C;-
20°C~60°C 2017-03-20 2018-03-20
Standard Light
Source EVERFINE D908 1012003 N/A 2016-12-17 2017-12-17
Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).
4. Test Method
Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of thesample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.
Integrating Sphere System
The system includes AC power source, digital power meter, DC power supply, Spectroradiometer, and integrating sphere. The integrating sphere system is calibrated by standard spectrum light source before measurement.
4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.
The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2) , at the 95% confidence level.
The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.
Goniophotometer System
The goniophotometer system is calibrated by standard light source before measurement.
Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The vertical angle (γ) test intervals were set no more than 1 degree while data for 5 degree intervals is reported. The horizontal angle (C plane) test intervals were set no more than 22.5 degree.
The uncertainty of the luminous intensity is U=1.6% (K=2) , at the 95% confidence level.
Additional Test
The Additional Test item may not be covered by IESNA LM-79-2008. Additional test is THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.
The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.
Fidelity Index and Gamut Index Calculation
The Rf, Rg was calculated according to IES TM-30-15 by using calculation tools. The calculation was based on the
measured SPD from 380nm to 780nm with 1nm intervals. All the colors in this report is for reference only.
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 4 of 15
5. Test Result
[Integrating Sphere System]
Total operating time for integrating sphere test: 1.0 hour
Test orientation: Downward
Photometric and Electrical Measurement Result
Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor Luminous Flux(lm)
Efficacy (lm/W)
230.0 50 0.4136 93.51 0.983 14106 150.86
Radiant Flux (W) CCT (K) Duv x y u' v'
42.78 4166 0.0000316 0.3734 0.3723 0.2222 0.4986
Color Rendering Index
Ra
82.0
R1 R2 R3 R4
80 88 93 81
R5 R6 R7 R8
80 82 86 65
R9 R10 R11 R12
6 70 80 58
R13 R14 R15
82 96 75
-20 0 20 40 60 80 100
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 5 of 15
Fidelity Index and Gamut Index
Fidelity Index Rf 81
Gamut Index Rg 96
Spectral Power Distribution Comparison
Plot of Rg versus Rf
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
380 430 480 530 580 630 680 730 780
SPD
(n
orm
aliz
ed
to
Y=1
00
)
l (nm)
Test source Reference source
60
70
80
90
100
110
120
130
140
50 60 70 80 90 100
Rg
Rf
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 6 of 15
Chroma Shift by Hue Rf by Hue
Color Vector Graphic
-20%
-15%
-10%
-5%
0%
5%
10%
15%
20%
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Hue Bin
50
55
60
65
70
75
80
85
90
95
100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Hue Bin
Refenerce Illuminat Test Source
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 7 of 15
Color Fidelity by CES Sample
0 20 40 60 80 100
CES01
CES03
CES05
CES07
CES09
CES11
CES13
CES15
CES17
CES19
CES21
CES23
CES25
CES27
CES29
CES31
CES33
CES35
CES37
CES39
CES41
CES43
CES45
CES47
CES49
CES51
CES53
CES55
CES57
CES59
CES61
CES63
CES65
CES67
CES69
CES71
CES73
CES75
CES77
CES79
CES81
CES83
CES85
CES87
CES89
CES91
CES93
CES95
CES97
CES99
Fidelity Index, Rf
Co
lor
Eval
uat
ion
Sam
ple
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 8 of 15
Relative Spectral Power Distribution
nm mW nm mW nm mW nm mW nm mW
380 3.361E+00 421 1.495E+01 462 1.485E+02 503 1.207E+02 544 1.940E+02
381 3.042E+00 422 1.660E+01 463 1.433E+02 504 1.243E+02 545 1.950E+02
382 2.764E+00 423 1.849E+01 464 1.378E+02 505 1.278E+02 546 1.958E+02
383 2.533E+00 424 2.046E+01 465 1.319E+02 506 1.308E+02 547 1.970E+02
384 2.399E+00 425 2.294E+01 466 1.262E+02 507 1.341E+02 548 1.980E+02
385 2.290E+00 426 2.572E+01 467 1.192E+02 508 1.372E+02 549 1.992E+02
386 2.064E+00 427 2.868E+01 468 1.123E+02 509 1.400E+02 550 2.001E+02
387 2.243E+00 428 3.241E+01 469 1.050E+02 510 1.429E+02 551 2.011E+02
388 2.327E+00 429 3.624E+01 470 9.739E+01 511 1.463E+02 552 2.021E+02
389 2.078E+00 430 4.056E+01 471 9.084E+01 512 1.484E+02 553 2.034E+02
390 1.935E+00 431 4.520E+01 472 8.458E+01 513 1.509E+02 554 2.049E+02
391 1.880E+00 432 5.032E+01 473 7.893E+01 514 1.538E+02 555 2.059E+02
392 1.786E+00 433 5.655E+01 474 7.455E+01 515 1.561E+02 556 2.072E+02
393 1.746E+00 434 6.307E+01 475 7.138E+01 516 1.583E+02 557 2.082E+02
394 1.705E+00 435 7.046E+01 476 6.918E+01 517 1.601E+02 558 2.096E+02
395 1.822E+00 436 7.906E+01 477 6.768E+01 518 1.624E+02 559 2.107E+02
396 1.915E+00 437 8.886E+01 478 6.644E+01 519 1.640E+02 560 2.117E+02
397 1.857E+00 438 9.996E+01 479 6.626E+01 520 1.659E+02 561 2.130E+02
398 1.942E+00 439 1.121E+02 480 6.628E+01 521 1.676E+02 562 2.146E+02
399 1.976E+00 440 1.269E+02 481 6.651E+01 522 1.692E+02 563 2.159E+02
400 2.061E+00 441 1.431E+02 482 6.680E+01 523 1.707E+02 564 2.168E+02
401 2.146E+00 442 1.626E+02 483 6.731E+01 524 1.724E+02 565 2.183E+02
402 2.226E+00 443 1.836E+02 484 6.797E+01 525 1.735E+02 566 2.191E+02
403 2.364E+00 444 2.066E+02 485 6.890E+01 526 1.752E+02 567 2.207E+02
404 2.554E+00 445 2.305E+02 486 6.965E+01 527 1.761E+02 568 2.220E+02
405 2.742E+00 446 2.551E+02 487 7.115E+01 528 1.774E+02 569 2.228E+02
406 3.016E+00 447 2.775E+02 488 7.242E+01 529 1.790E+02 570 2.241E+02
407 3.129E+00 448 2.973E+02 489 7.429E+01 530 1.795E+02 571 2.254E+02
408 3.564E+00 449 3.112E+02 490 7.676E+01 531 1.802E+02 572 2.262E+02
409 3.883E+00 450 3.184E+02 491 7.910E+01 532 1.818E+02 573 2.273E+02
410 4.364E+00 451 3.161E+02 492 8.194E+01 533 1.831E+02 574 2.285E+02
411 4.778E+00 452 3.067E+02 493 8.507E+01 534 1.840E+02 575 2.296E+02
412 5.318E+00 453 2.917E+02 494 8.826E+01 535 1.849E+02 576 2.308E+02
413 5.934E+00 454 2.719E+02 495 9.178E+01 536 1.861E+02 577 2.317E+02
414 6.668E+00 455 2.490E+02 496 9.532E+01 537 1.869E+02 578 2.323E+02
415 7.508E+00 456 2.264E+02 497 9.884E+01 538 1.878E+02 579 2.339E+02
416 8.506E+00 457 2.062E+02 498 1.027E+02 539 1.891E+02 580 2.346E+02
417 9.478E+00 458 1.888E+02 499 1.064E+02 540 1.895E+02 581 2.353E+02
418 1.071E+01 459 1.749E+02 500 1.100E+02 541 1.910E+02 582 2.359E+02
419 1.200E+01 460 1.630E+02 501 1.138E+02 542 1.919E+02 583 2.370E+02
420 1.336E+01 461 1.551E+02 502 1.174E+02 543 1.931E+02 584 2.373E+02
0.0
0.2
0.4
0.6
0.8
1.0
380 430 480 530 580 630 680 730 780
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 9 of 15
nm mW nm mW nm mW nm mW nm mW
585 2.378E+02 626 1.885E+02 667 7.743E+01 708 2.301E+01 749 6.446E+00
586 2.386E+02 627 1.858E+02 668 7.532E+01 709 2.221E+01 750 6.351E+00
587 2.389E+02 628 1.830E+02 669 7.327E+01 710 2.147E+01 751 6.054E+00
588 2.392E+02 629 1.804E+02 670 7.129E+01 711 2.093E+01 752 5.975E+00
589 2.398E+02 630 1.773E+02 671 6.913E+01 712 2.038E+01 753 5.724E+00
590 2.398E+02 631 1.745E+02 672 6.735E+01 713 1.965E+01 754 5.613E+00
591 2.401E+02 632 1.713E+02 673 6.572E+01 714 1.899E+01 755 5.327E+00
592 2.404E+02 633 1.681E+02 674 6.388E+01 715 1.843E+01 756 5.328E+00
593 2.399E+02 634 1.657E+02 675 6.194E+01 716 1.790E+01 757 5.130E+00
594 2.398E+02 635 1.626E+02 676 6.060E+01 717 1.738E+01 758 4.979E+00
595 2.395E+02 636 1.598E+02 677 5.864E+01 718 1.689E+01 759 4.819E+00
596 2.398E+02 637 1.567E+02 678 5.691E+01 719 1.625E+01 760 4.669E+00
597 2.391E+02 638 1.539E+02 679 5.532E+01 720 1.585E+01 761 4.601E+00
598 2.386E+02 639 1.507E+02 680 5.365E+01 721 1.541E+01 762 4.467E+00
599 2.379E+02 640 1.480E+02 681 5.236E+01 722 1.484E+01 763 4.340E+00
600 2.371E+02 641 1.449E+02 682 5.065E+01 723 1.435E+01 764 4.250E+00
601 2.367E+02 642 1.420E+02 683 4.922E+01 724 1.395E+01 765 4.166E+00
602 2.356E+02 643 1.389E+02 684 4.781E+01 725 1.361E+01 766 3.966E+00
603 2.346E+02 644 1.362E+02 685 4.638E+01 726 1.316E+01 767 3.978E+00
604 2.335E+02 645 1.333E+02 686 4.506E+01 727 1.272E+01 768 3.756E+00
605 2.325E+02 646 1.302E+02 687 4.378E+01 728 1.224E+01 769 3.609E+00
606 2.313E+02 647 1.274E+02 688 4.244E+01 729 1.199E+01 770 3.572E+00
607 2.300E+02 648 1.246E+02 689 4.114E+01 730 1.156E+01 771 3.358E+00
608 2.283E+02 649 1.219E+02 690 3.976E+01 731 1.131E+01 772 3.371E+00
609 2.267E+02 650 1.191E+02 691 3.877E+01 732 1.085E+01 773 3.186E+00
610 2.250E+02 651 1.164E+02 692 3.757E+01 733 1.064E+01 774 3.087E+00
611 2.239E+02 652 1.135E+02 693 3.640E+01 734 1.026E+01 775 3.070E+00
612 2.216E+02 653 1.109E+02 694 3.528E+01 735 9.887E+00 776 3.096E+00
613 2.196E+02 654 1.082E+02 695 3.424E+01 736 9.692E+00 777 2.924E+00
614 2.176E+02 655 1.056E+02 696 3.331E+01 737 9.284E+00 778 2.828E+00
615 2.156E+02 656 1.033E+02 697 3.222E+01 738 8.983E+00 779 2.833E+00
616 2.136E+02 657 1.007E+02 698 3.128E+01 739 8.800E+00 780 2.838E+00
617 2.115E+02 658 9.796E+01 699 3.041E+01 740 8.438E+00
618 2.085E+02 659 9.573E+01 700 2.950E+01 741 8.268E+00
619 2.065E+02 660 9.300E+01 701 2.864E+01 742 7.963E+00
620 2.044E+02 661 9.056E+01 702 2.773E+01 743 7.832E+00
621 2.020E+02 662 8.846E+01 703 2.679E+01 744 7.539E+00
622 1.993E+02 663 8.634E+01 704 2.589E+01 745 7.310E+00
623 1.964E+02 664 8.396E+01 705 2.519E+01 746 7.127E+00
624 1.940E+02 665 8.183E+01 706 2.442E+01 747 6.922E+00
625 1.912E+02 666 7.968E+01 707 2.367E+01 748 6.729E+00
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 10 of 15
CIE 1931 x y Chromaticity Diagram
7-Step Chromaticity Quadrangles
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0.30
0.35
0.40
0.45
0.30 0.35 0.40 0.45 0.50 0.55
sample
7-STEP 2200K
7-STEP 2500K
7-STEP 2700K
7-STEP 3000K
7-STEP 3500K
7-STEP 4000K
7-STEP 4500K
7-STEP 5000K
7-STEP 5700K
7-STEP 6500K
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 11 of 15
[Goniophotometer System]
Total operating time for luminous intensity distribution: 1.0 hour
Test orientation: Downward
Electrical Measurement
Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor
230.1 50 0.4122 93.2 0.9828
Photometric Measurement
Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)
14133.2 151.64 5264.0 1.28 1.27
Luminous Intensity Distribution
C0/180 C45/225 C90/270 C135/315 AVG.
Beam Angle (50% Imax): 113.6 113.9 114.5 113.9 114.0
Field Angle (10% Imax): 147.7 147.5 147.5 147.9 147.7
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 12 of 15
Luminous Intensity (cd) Distribution Data
C 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5°
γ
0.0° 5263 5263 5263 5263 5263 5263 5263 5263
5.0° 5243 5246 5257 5260 5259 5258 5256 5251
10.0° 5193 5208 5214 5219 5222 5222 5227 5222
15.0° 5101 5121 5132 5148 5150 5157 5158 5148
20.0° 4950 4968 4986 4991 4995 5017 5028 5011
25.0° 4735 4732 4741 4753 4770 4787 4804 4803
30.0° 4443 4434 4444 4446 4450 4492 4523 4535
35.0° 4100 4103 4102 4081 4072 4123 4183 4201
40.0° 3779 3782 3776 3750 3739 3767 3826 3862
45.0° 3488 3496 3498 3505 3508 3506 3531 3561
50.0° 3153 3159 3172 3196 3212 3210 3223 3243
55.0° 2720 2721 2742 2777 2818 2819 2829 2845
60.0° 2171 2153 2169 2184 2236 2260 2286 2310
65.0° 1565 1555 1560 1574 1612 1665 1709 1731
70.0° 882 866 871 910 948 986 1015 1035
75.0° 329 327 331 347 367 408 432 448
80.0° 43 40 43 50 58 51 62 67
85.0° 5 4 4 5 5 6 6 7
90.0° 1 1 1 1 1 1 1 1
95.0° 1 1 1 1 1 1 1 1
100.0° 1 1 1 1 1 1 1 1
105.0° 1 1 1 1 1 1 1 1
110.0° 2 2 2 2 2 2 1 1
115.0° 2 2 2 2 2 2 2 2
120.0° 2 2 2 2 2 2 2 2
125.0° 2 2 2 2 2 2 2 2
130.0° 2 2 2 2 2 2 2 2
135.0° 3 3 3 3 3 3 3 3
140.0° 4 4 4 4 4 4 4 4
145.0° 4 5 5 5 5 5 5 4
150.0° 5 6 6 6 6 6 6 5
155.0° 6 6 6 6 7 7 7 6
160.0° 7 7 7 7 7 7 7 7
165.0° 7 7 7 7 7 7 7 7
170.0° 6 6 6 6 6 6 7 7
175.0° 6 6 6 6 6 6 6 6
180.0° 6 5 5 5 5 5 6 6
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 13 of 15
Luminous Intensity (cd) Distribution Data (cont.)
C 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5°
γ
0.0° 5263 5263 5263 5263 5263 5263 5263 5263
5.0° 5252 5255 5261 5263 5260 5259 5255 5249
10.0° 5214 5233 5238 5242 5233 5231 5220 5216
15.0° 5137 5165 5188 5190 5183 5179 5159 5138
20.0° 5005 5039 5059 5060 5044 5050 5029 4998
25.0° 4814 4834 4849 4840 4822 4817 4807 4774
30.0° 4555 4572 4573 4554 4529 4517 4506 4484
35.0° 4231 4243 4237 4191 4156 4162 4166 4148
40.0° 3896 3912 3898 3842 3800 3803 3819 3809
45.0° 3601 3617 3618 3595 3575 3543 3527 3520
50.0° 3285 3310 3317 3313 3300 3255 3220 3191
55.0° 2900 2920 2927 2942 2931 2872 2816 2776
60.0° 2366 2367 2359 2356 2340 2293 2258 2227
65.0° 1787 1779 1768 1748 1708 1691 1664 1630
70.0° 1101 1092 1068 1057 1028 1012 986 955
75.0° 484 479 471 449 420 418 404 377
80.0° 90 89 84 71 65 56 48 46
85.0° 8 8 7 7 7 6 6 6
90.0° 0 0 0 0 0 0 0 0
95.0° 0 0 0 0 0 0 0 0
100.0° 1 1 1 1 1 1 1 1
105.0° 1 1 1 1 1 1 1 1
110.0° 1 1 1 1 1 1 1 1
115.0° 1 1 1 1 1 1 1 1
120.0° 1 1 1 1 1 1 1 1
125.0° 2 2 2 2 2 2 2 2
130.0° 2 2 2 2 2 2 2 2
135.0° 2 2 2 2 2 2 2 2
140.0° 3 3 3 3 3 3 3 3
145.0° 3 3 3 3 3 3 3 3
150.0° 3 3 3 4 4 4 3 4
155.0° 4 4 4 4 4 4 4 4
160.0° 4 4 4 4 4 4 4 4
165.0° 4 4 4 4 4 4 4 4
170.0° 4 4 4 4 4 4 4 5
175.0° 5 5 5 5 5 4 5 5
180.0° 6 6 5 5 5 5 5 6
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 14 of 15
Zonal Lumen Density Measurement
Deg Flux (lm) % Deg Flux (lm) %
0-5 125.7 0.89 0-5 125.7 0.89
5-10 374.9 2.65 0-10 500.6 3.54
10-15 615.7 4.36 0-15 1116.3 7.90
15-20 838.6 5.93 0-20 1954.8 13.83
20-25 1028.8 7.28 0-25 2983.7 21.11
25-30 1177.1 8.33 0-30 4160.8 29.44
30-35 1275.0 9.02 0-35 5435.8 38.46
35-40 1327.3 9.39 0-40 6763.1 47.85
40-45 1361.1 9.63 0-45 8124.2 57.48
45-50 1371.0 9.70 0-50 9495.1 67.18
50-55 1323.3 9.37 0-55 10818.5 76.55
55-60 1184.9 8.38 0-60 12003.3 84.93
60-65 960.6 6.80 0-65 12964.0 91.73
65-70 673.2 4.76 0-70 13637.2 96.49
70-75 357.0 2.53 0-75 13994.2 99.02
75-80 112.5 0.79 0-80 14106.7 99.81
80-85 11.6 0.08 0-85 14118.3 99.89
85-90 1.2 0.01 0-90 14119.5 99.90
90-95 0.3 0.01 0-95 14119.8 99.91
95-100 0.4 0.00 0-100 14120.2 99.91
100-105 0.5 0.00 0-105 14120.7 99.91
105-110 0.6 0.01 0-110 14121.3 99.92
110-115 0.7 0.00 0-115 14121.9 99.92
115-120 0.7 0.01 0-120 14122.6 99.93
120-125 0.8 0.00 0-125 14123.4 99.93
125-130 0.9 0.01 0-130 14124.2 99.94
130-135 1.0 0.00 0-135 14125.2 99.94
135-140 1.1 0.01 0-140 14126.3 99.95
140-145 1.2 0.01 0-145 14127.5 99.96
145-150 1.3 0.01 0-150 14128.8 99.97
150-155 1.2 0.01 0-155 14130.0 99.98
155-160 1.1 0.01 0-160 14131.1 99.99
160-165 0.9 0.00 0-165 14132.0 99.99
165-170 0.7 0.01 0-170 14132.7 100.00
170-175 0.4 0.00 0-175 14133.1 100.00
175-180 0.1 0.00 0-180 14133.2 100.00
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road,
Futian Free Trade Zone, Shenzhen, Guangdong, China.
The NVLAP Lab Code is 200707-0
Page 15 of 15
[Additional Test]
Test Item Test Voltage (V) Frequency (Hz) Test Result
Total Harmonic Distortion: 230.0 50 7.44%
6. Product Photo
***********END OF REPORT***********