hdlsp-035-xxxx-x-mktsuddendocs.samtec.com/prints/hdlsp-035-xxxx-x-mkt.pdfthis document contains...

9
THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC. PROPRIETARY NOTE * * DESIGNED & DIMENSIONED IN MILLIMETERS[INCHES] THIS PRODUCT MANUFACTURED WITH LEAD-FREE PROCESSING Pb DO NOT SCALE FROM THIS PRINT ASSEMBLY LENGTH -0120 - 9999 MM (SEE NOTE 10) HDLSP-035-XXXX-X OPTION *-L: POSITIVE LATCH * = NOT RELEASED 35.13 REF (TYP) 1.383 25.50 1.004 REF 22.85 .900 REF FIG 1 HDLSP-035-XXXX SHOWN (SOME COMPONENTS NOT SHOWN IN ALL VIEWS FOR CLARITY) (SEE SHEET 5 FOR BOM) 6 C L (TYP BOTH ENDS) 2 4.58 REF .180 6.10 REF .240 4 5 9 5 4 1 11 11 10 J2 J1 9 10 CAP REMOVED FOR CLARITY ASSEMBLY LENGTH ±1% (SEE NOTE 6) 7 C A35 B35 A1 B1 A1 B1 A35 B35 C SHEET OF UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE IN MILLIMETERS. TOLERANCES ARE: DECIMALS ANGLES X.X: 0.3 [.01] 2 X.XX: 0.13 [.005] X.XXX: 0.051 [.0020] MATERIAL: HIGH SPEED CABLE ASSEMBLY BY: HDLSP-035-XXXX-X DWG. NO. DESCRIPTION: DO NOT SCALE DRAWING CLAY W 10/114/2010 9 1 SHEET SCALE: 3:2 F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW NOTES: 1. REPRESENTS A CRITICAL DIMENSION. 2. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED FOR SHORTS AND OPENS. 3. NOTE DELETED. 4. NOTE DELETED. 5. MEASURE 6.10 DIMENSION ACROSS DIE CASTINGS, 2.0mm FROM BACK EDGE OF DIE CASTINGS. 6. HDRL-11 IS TO BE CENTERED ON CABLE AS SHOWN. HDRL-11 IS TO CONTAIN: PART NUMBER, SHOP ORDER & DATE CODE. 7. NOTE DELETED. 8. FOR ASSEMBLY LENGTHS 450MM & LONGER, WRAP THE CABLES WITH ELECTRICAL TAPE AT SYMMETRIC INTERVALS APPROXIMATELY 1 FT APART. CUT TAPE TO 3" LENGTHS. 9. PARTS TO BE PACKAGED IN CLEAR POLY-BAGS. 10. TEST DATA ONLY AVAILABLE UP TO 2000 MM. 520 PARK EAST BLVD, NEW ALBANY, IN 47150 PHONE: 812-944-6733 FAX: 812-948-5047 e-Mail [email protected] code 55322 INSULATOR: LCP TERMINAL: PHOS BRONZE CABLE MATERIAL: JACKET: PVC INSULATOR: DIELECTRIC CONDUCTORS: COPPER BRAID: TINNED COPPER COVERS: DIECAST ZINC ALLOY REVISION M

Upload: lytuong

Post on 06-Jul-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

DESIGNED & DIMENSIONEDIN MILLIMETERS[INCHES]

THIS PRODUCT MANUFACTUREDWITH LEAD-FREE PROCESSINGPb

DO NOTSCALE FROM

THIS PRINTASSEMBLY LENGTH-0120 - 9999 MM (SEE NOTE 10)

HDLSP-035-XXXX-XOPTION*-L: POSITIVE LATCH

* = NOT RELEASED

35.13 REF (TYP)1.383

25.50 1.004REF

22.85 .900REF

FIG 1HDLSP-035-XXXX SHOWN

(SOME COMPONENTS NOT SHOWNIN ALL VIEWS FOR CLARITY)

(SEE SHEET 5 FOR BOM)

6

CL

(TYP BOTH ENDS) 2

4.58 REF.180

6.10 REF.240

4

59

5

41

111110

J2J1

9

10

CAP REMOVED FOR CLARITY

ASSEMBLY LENGTH ±1%

(SEE NOTE 6)7

C A35 B35

A1 B1A1 B1

A35 B35

C

SHEET OF

UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE IN MILLIMETERS.TOLERANCES ARE:DECIMALS ANGLESX.X: 0.3 [.01] 2 X.XX: 0.13 [.005]X.XXX: 0.051 [.0020]MATERIAL:

HIGH SPEED CABLE ASSEMBLY

BY:HDLSP-035-XXXX-X

DWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 91

SHEET SCALE: 3:2

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

NOTES:

1. REPRESENTS A CRITICAL DIMENSION.2. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED FOR SHORTS AND OPENS.3. NOTE DELETED.4. NOTE DELETED.5. MEASURE 6.10 DIMENSION ACROSS DIE CASTINGS, 2.0mm FROM BACK EDGE OF DIE CASTINGS.6. HDRL-11 IS TO BE CENTERED ON CABLE AS SHOWN. HDRL-11 IS TO CONTAIN: PART NUMBER, SHOP ORDER & DATE CODE.7. NOTE DELETED.8. FOR ASSEMBLY LENGTHS 450MM & LONGER, WRAP THE CABLES WITH ELECTRICAL TAPE AT SYMMETRIC INTERVALS APPROXIMATELY 1 FT APART. CUT TAPE TO 3" LENGTHS.9. PARTS TO BE PACKAGED IN CLEAR POLY-BAGS.10. TEST DATA ONLY AVAILABLE UP TO 2000 MM.

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

INSULATOR: LCPTERMINAL: PHOS BRONZECABLE MATERIAL: JACKET: PVC INSULATOR: DIELECTRIC CONDUCTORS: COPPER BRAID: TINNED COPPERCOVERS: DIECAST ZINC ALLOY

REVISION M

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

ASSEMBLY LENGTH +/-1%

ASSEMBLY LENGTH-30.80[1.213]

IN PROCESS 1SOLDER CABLE TO PCB SUB

(APPLY TO NO OPTION AND POSITIVE LATCH OPTION)

SOLDER TERMINATE CABLE CONDUCTORS TO MATING CARDS

SOLDER TERMINATE CABLE SHIELDS TO MATING CARDS

C

C

PCB SIDE ID

PIN A1

PIN A35PIN B35

PIN B1

3

3

1

J2J1

SHEET OF

HIGH SPEED CABLE ASSEMBLY

BY:

HDLSP-035-XXXX-XDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 92

SHEET SCALE: 1:1

REVISION M

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

4.63 .182 IN PROCESS 2ADD HT3-035-02 (BOTTOM HOUSING)

PLACE CABLE SUB-ASSY INTO BOTTOM HOUSINGTAKE CARE TO ALIGN OFFSET GUIDE POSTS.

C 5 5

IN PROCESS 3ADD HT3-DMT-035-01 (PULL TAB)

(SECOND END PULL TAB NOT SHOWN FOR CLARITY)

PLACE PULL TAP INTO BOTTOM HOUSINGON BACK POSTS.

5

6

SHEET OF

HIGH SPEED CABLE ASSEMBLY

BY:

HDLSP-035-XXXX-XDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 93

SHEET SCALE: 1:2

REVISION M

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

APPROX. 10.0°

IN PROCESS 4ADD HT3-035-01 (TOP HOUSING)

(SECOND END PULL TAB NOT SHOWN FOR CLARITY)

4

5 4

5

10

1010

1011

1111

11

2 (TYP BOTH ENDS)

4.58 .180 6.10±0.20 .240±.008(SEE NOTE 5)

2.0 .08(SEE NOTE 5)

IN PROCESS 5A) LTC-25-01 (LATCH)

B) ADD OR-113-35 (ORING)C) ADD LTC-23-01 (LATCH)

D) ADD VCOV-HT3-035-ORG (AFTER E-TEST)

C9

9

CAP REMOVED FOR CLARITY

SHEET OF

HIGH SPEED CABLE ASSEMBLY

BY:

HDLSP-035-XXXX-XDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 94

SHEET SCALE: 1:2

REVISION M

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

(OAL / 2) 12.70

304.80 12.000 12.70 304.80 12.000 12.70

13

CL

TAPE VIEW APPLICATION WHEN ITEM 13 QTY IS ODD

(OAL / 2) 12.70

152.40 6.000 12.70152.40 6.000 12.70

13

CL

TAPE VIEW APPLICATION WHEN ITEM 13 QTY IS EVEN

FOLLOWING TAPES TO BE SPACED PER NOTE 8

SHEET OF

HIGH SPEED CABLE ASSEMBLY

BY:

HDLSP-035-XXXX-XDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 95

SHEET SCALE: 1:2

REVISION M

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

25.55 1.006REF

2 (TYP BOTH ENDS)

CL

5.54 .218 REF

FIG 2HDLSP-035-XXXX-L SHOWN

(SOME COMPONENTS NOT SHOWNIN ALL VIEWS FOR CLARITY)

(DIFFERENT AS SHOWN, OTHERWISE SAME AS FIG 1)

15

4 5

4

8

9

8

9

CAP REMOVED FOR CLARITY

7 (SEE NOTE 6)

SHEET OF

HIGH SPEED CABLE ASSEMBLY

BY:

HDLSP-035-XXXX-XDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 96

SHEET SCALE: 3:2

REVISION M

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

'A' "B" "B"

IN PROCESS 3ADD SUB-HDLSP-LT-01 (PULL TAB)

(SECOND END PULL TAB NOT SHOWN FOR CLARITY)

6

DETAIL 'A'SCALE 16 : 1

TIP OF LATCH MUST BE ONOUTER SURFACE OF HOUSING

4.63 .182

PLACE CABLE SUB-ASSY INTO BOTTOM HOUSINGTAKE CARE TO ALIGN OFFSET GUIDE POSTS.

IN PROCESS 2ADD HT3-035-02-L (BOTTOM HOUSING)

C 5 5

3

SEE SHEET 2 FOR IN-PROCESS 1

SECTION "B"-"B"SCALE 4 : 1

SPRING MUST BE INSTALLED

SHEET OF

HIGH SPEED CABLE ASSEMBLY

BY:

HDLSP-035-XXXX-XDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 97

SHEET SCALE: 3:2

REVISION M

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

8

8

2

8

8

(TYP BOTH ENDS)

5.54 .218 6.10±0.20 .240±.008(SEE NOTE 5)

2.0 .08(SEE NOTE 5)

C

CAP REMOVED FOR CLARITY9

IN PROCESS 5A) LTC-25-01 (LATCH)

B) ADD OR-113-35 (ORING)C) ADD VCOV-HT3-035-ORG (AFTER E-TEST)

9

APPROX. 10.0°

IN PROCESS 4ADD HT3-035-01-L (TOP HOUSING)

(SECOND END PULL TAB NOT SHOWN FOR CLARITY)

5

54

4

SHEET OF

HIGH SPEED CABLE ASSEMBLY

BY:

HDLSP-035-XXXX-XDWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 98

SHEET SCALE: 3:2

REVISION M

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

520 PARK EAST BLVD, NEW ALBANY, IN 47150PHONE: 812-944-6733 FAX: 812-948-5047e-Mail [email protected] code 55322

THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION AND ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, PATENT RIGHTS AND SALES RIGHTS ARE EXPRESSLY RESERVED BY SAMTEC, INC. THIS DOCUMENT SHALL NOT BE DISCLOSED, IN WHOLE OR PART, TO ANY UNAUTHORIZED PERSON OR ENTITY NOR REPRODUCED, TRANSFERRED OR INCORPORATED IN ANY OTHER PROJECT IN ANY MANNER WITHOUT THE EXPRESS WRITTEN CONSENT OF SAMTEC, INC.

PROPRIETARY NOTE* *

PULL TAB ON BOTTOM

PULL TAB ON TOP

FINISHED ASSEMBLYCHECK PULL TAB ORIENTATION BEFORE PACKAGING

B35 A35

B1 A1

B35 A35

B1 A1

HIGH SPEED CABLE ASSEMBLY

SHEET OFBY:HDLSP-035-XXXX-X

DWG. NO.

DESCRIPTION:DO NOT SCALE DRAWING

CLAY W 10/114/2010 99SHEET SCALE: 3:2

F:\DWG\MISC\MKTG\HDLSP-035-XXXX-X-MKT.SLDDRW

REVISION M