Toll-Free: 1.877.884.TEST (8378) | Fax: 954.697.8211 [email protected] | www.WorldofTest.com USA Canada UAE Mexico India Hong Kong TESTING ADVANCED TECHNOLOGIES Applications HV-3000-D3/D6 Lightweight and compact HDT/VICAT tester. It is designed to measure heat deflec- tion temperature and VICAT softening temperature for evaluation of thermal property of plastic materials. HV-3000-P3/P6 Bench type HDT/VICAT tester. It is designed to measure heat deflection temperature and VICAT softening temperature for evaluation of thermal property of plastic materi- als. This tester features high precision temperature ramp rate control. LVDT sensor is used on each station to ensure high accuracy of deflection measurement. HV-3000-P3C/P6C Floor model HDT/VICAT tester. Application same as above. With a built in water chiller, the oil bath can be cooled down faster and easier without connecting to an external water supply. This model comes with the high precision temperature ramp rate control and LVDT sensors. The operator can easily monitor real-time graph, start cooling, modify test condition and edit test report in a few simple steps with the HDT software. Moreover, our HDT software can automatically calculate required loading weight based on specified test conditions and save test result. VICAT Softening temperature "VICAT softening temperature" or "VICAT hardness is the determination of the softening point for materials that have no definite melting point, such as plastics. It is taken as the temperature at which the specimen is penetrated to a depth of 1 mm by a flat-ended needle with a 1 mm2 circular or square cross-section. For the VICAT A test, a load of 10 N is used. For the VICAT B test, the load is 50 N. Standards to determine VICAT softening point include ASTM D 1525 and ISO 306, which are largely equivalent Heat deflection temperature The heat deflection temperature or heat distortion temperature (HDT, HDTUL, or DTUL) is the temperature at which a polymer or plastic sample deforms under a specified load. This property of a given plastic material is applied in many aspects of product design, engineering, and manufacture of products using thermoplastic components. Applicable Standards HDT Test: ISO 306, ASTM D1525, DIN 53460 and equivalents VICAT Test: ISO 75, ASTM D648, DIN 53461 and equivalents HDT / VICAT Heat Deflection Tester – HV-3000 Series www.WorldofTest.com/hdtvicat-heat-deflection-testers ASTM-D648, ASTM-D1525, ISO-75, ISO-306, DIN 53461, DIN 53460

Upload: voque

Post on 10-May-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

Toll-Free: 1.877.884.TEST (8378) | Fax: 954.697.8211

[email protected] | www.WorldofTest.com

USA Canada UAE Mexico India Hong Kong

TESTINGADVANCED

TECHNOLOGIES

Applications HV-3000-D3/D6Lightweight and compact HDT/VICAT tester. It is designed to measure heat deflec-tion temperature and VICAT softening temperature for evaluation of thermal property of plastic materials.

HV-3000-P3/P6Bench type HDT/VICAT tester. It is designed to measure heat deflection temperature and VICAT softening temperature for evaluation of thermal property of plastic materi-als. This tester features high precision temperature ramp rate control. LVDT sensor is used on each station to ensure high accuracy of deflection measurement.

HV-3000-P3C/P6CFloor model HDT/VICAT tester. Application same as above. With a built in water chiller, the oil bath can be cooled down faster and easier without connecting to an external water supply. This model comes with the high precision temperature ramp rate control and LVDT sensors. The operator can easily monitor real-time graph, start cooling, modify test condition and edit test report in a few simple steps with the HDT software. Moreover, our HDT software can automatically calculate required loading weight based on specified test conditions and save test result.

VICAT Softening temperature"VICAT softening temperature" or "VICAT hardness is the determination of the softening point for materials that have no definite melting point, such as plastics. It is taken as the temperature at which the specimen is penetrated to a depth of 1 mm by a flat-ended needle with a 1 mm2 circular or square cross-section. For the VICAT A test, a load of 10 N is used. For the VICAT B test, the load is 50 N.Standards to determine VICAT softening point include ASTM D 1525 and ISO 306, which are largely equivalent

Heat deflection temperatureThe heat deflection temperature or heat distortion temperature (HDT, HDTUL, or DTUL) is the temperature at which a polymer or plastic sample deforms under a specified load. This property of a given plastic material is applied in many aspects of product design, engineering, and manufacture of products using thermoplastic components.

Applicable Standards HDT Test: ISO 306, ASTM D1525, DIN 53460 and equivalentsVICAT Test: ISO 75, ASTM D648, DIN 53461 and equivalents

HDT / VICAT Heat Deflection Tester – HV-3000 Series

www.WorldofTest.com/hdtvicat-heat-deflection-testersASTM-D648, ASTM-D1525, ISO-75, ISO-306, DIN 53461, DIN 53460

Toll-Free: 1.877.884.TEST (8378) | Fax: 954.697.8211

[email protected] | www.WorldofTest.com

USA Canada UAE Mexico India Hong Kong

TESTING TECHNOLOGIES

ModelOperating systemTest stationDeflection measuring sensorDeflection / penetration measuring rangeTemp. rangeHeating rateCooling methodTest methodDimension (W×D×H)Power

HV-3000-D3/D6HMI touchscreen + PLC3 or 6Digital indicator0 to 5 mm (resolution: 0.01 mm)Ambient temp. 300.0℃ (PID control)2±0.2℃/min(HDT) / 50±5℃/hr(VICAT)Water pipingHDT and VICAT915×476×475 mm1 phase AC 220V 50Hz (or specify)

Specifications

ModelStandardOperating systemTest stationDeflection / penetration measuring rangeTemp. rangeHeating rateTemp. control accuracyCooling methodStirring methodTest methodCool down time (water piping)Power

HV-3000-P3/P6ASTM-D1525、ASTM-D648、DIN53460、DIN53461、ISO-306、ISO-75PC based HDT software3 or 60.001 to 3.500mm (LVDT sensor)Ambient temp. to 300℃2±0.2℃/min (HDT) or 50±5℃/hr (VICAT)±0.5℃Built in water piping (standard); Water chiller (optional)Vortex stirrerHDT and VICAT300 to 35℃ within 40min (when water temp. is below 25℃)1 phase AC 220V 50Hz (or specify)

Toll-Free: 1.877.884.TEST (8378) | Fax: 954.697.8211

[email protected] | www.WorldofTest.com

USA Canada UAE Mexico India Hong Kong

TESTING TECHNOLOGIES

ModelStandardOperating systemTest stationDeflection / penetration measuring rangeSpan supportTemp. rangeTemp. control accuracyCooling methodStirring methodTest methodDimension (main unit)Weight (approx.)Power

HV-3000-P3C/P6CASTM-D1525、ASTM-D648、DIN53460、DIN53461、ISO-306、ISO-75PC based HDT software3 or 60.001 to 3.500mm (LV64mm, 100mm or 101.6mm (optional)Ambient temp. to 300°C±0.5°CBuilt in water chillerVortex stirrerHDT and VICAT1080 × 550 × 1500 mm200kg 1phase AC 220V 50Hz (or specify)