headlts ignition 1 park wiper relay 2 heat/ac led turn

2
510488 92972276 Instruction rev 0.0 3/13/2019 CAD Main Power Panel N HAZA 20 A 20 A 12 13 14 15 17 16 18 20 19 22 21 1 2 3 4 5 6 7 10 8 11 9 RELAY 1 OUT RELAY 1 GRD DOME STOP IGNITION 1 HEADLTS IGNITION 2 BATTERY 1 RADIO BATTERY 2 GAUGES ACCESSORY 1 PARK WIPER HEAT/AC HORN OUT HORN SWITCH RELAY 2 OUT RELAY 2 POS RELAY 2 GRD HAZARD TURN BREAKER 12V 30A 30A 30A 30A 30A 20A 15A 30A 15A 20A 30A 20A 10A 20A 30A 30A 20A 30A 15A 15A 30A 20A 30A 10A 20A 30A 20A 30A American Autowire 800-482-9473 BATTERY IN ACC OUT HORN RELAY 20 AMP RELAY LED TURN/HAZARD FLASHER HORN RELAY 20 AMP RELAY LED FLASHER 40 AMP RELAY www.americanautowire.com 856-933-0801 CIRCUIT # CIRCUIT RATING FUNCTION 1. RELAY 1 OUT Power from Relay 1 (Keyed) 2. RELAY 1 GRD Ground trigger to Relay 1 3. DOME 30 amp fuse 15 amp fuse Battery power to dome lights 4. STOP 15 amp fuse Battery power to brake switch 5. HEADLIGHTS Battery power for headlight sw. 30 amp breaker 6. IGNITION 1 30 amp fuse Ignition power - spare 7. IGNITION 2 20 amp fuse Ignition power - spare 8. BATTERY 1 30 amp fuse Battery power - spare 9. BATTERY 2 20 amp fuse Battery power - spare 10. RADIO 10 amp fuse Ignition power for radio 11. GAUGES 20 amp fuse Ignition power for gauges CIRCUIT # CIRCUIT RATING FUNCTION 12. ACCESSORY 1 30 amp Accessory power - spare 13. PARK 15 amp Battery power for park lamps 14. WIPER 20 amp Accessory power for wiper circuit 15. HEAT/AC 30 amp Accessory power for heater circuit 16. HORN OUT Relay power to horn (Battery) Relay trigger ground from horn switch 17. HORN SWITCH 30 amp 20 amp 20 amp Power from Relay 2 18. RELAY 2 OUT Trigger for Relay 2 (Key or Battery) 19. RELAY 2 POSITIVE Ground trigger for Relay 2 20. RELAY 2 GROUND 12 volt feed for hazard switch (Battery) 21. HAZARD 12 volt feed for turn switch (Keyed) 22. TURN Page 1 510488 MADE IN THE U.S.A. 40 AMP RELAY BATTERY 1 IGNITION 2 HEADLTS IGNITION 1 BATTERY 2 RADIO RELAY 1 GAUGES STOP/DOME ACCESSORY 1 PARK WIPER RELAY 2 HEAT/AC

Upload: others

Post on 06-Apr-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEADLTS IGNITION 1 PARK WIPER RELAY 2 HEAT/AC LED TURN

51048892972276 Instruction rev 0.0 3/13/2019 CAD

Main Power Panel

N

HAZA

20 A 20 A

12 13 14 15 1716 18 2019 22211 2 3 4 5 6 7 108 119

RELA

Y 1

OUT

RELA

Y 1

GRD

DOM

E

STOP

IGNI

TION

1HE

ADLT

S

IGNI

TION

2

BATT

ERY

1

RADI

O

BATT

ERY

2

GAUG

ES

ACCE

SSOR

Y 1

PARK

WIP

ER

HEAT

/AC

HORN

OUT

HORN

SW

ITCH

RELA

Y 2

OUT

RELA

Y 2

POS

RELA

Y 2

GRD

HAZA

RD

TURN

BREA

KER

12V

30A

30A

30A30A 30A20A 15A 30A15A

20A30A 20A10A 20A 30A30A

20A

30A

15A

15A

30A

20A

30A

10A

20A

30A

20A

30A

Am

eric

an A

utow

ire80

0-48

2-94

73BA

TTER

Y IN

ACC

OU

T

HO

RN R

ELAY

20 A

MP

RELA

Y

LED

TU

RN/H

AZA

RD

FLA

SHER

HO

RNRE

LAY

20 A

MP

RELA

Y

LED

FLA

SHER

40 A

MP

RELA

Y

www.americanautowire.com 856-933-0801

CIRCUIT# CIRCUIT RATING FUNCTION

1. RELAY 1 OUT Power from Relay 1 (Keyed)2. RELAY 1 GRD Ground trigger to Relay 13. DOME

30 amp fuse

15 amp fuse Battery power to dome lights4. STOP 15 amp fuse Battery power to brake switch5. HEADLIGHTS Battery power for headlight sw.30 amp breaker6. IGNITION 1 30 amp fuse Ignition power - spare7. IGNITION 2 20 amp fuse Ignition power - spare8. BATTERY 1 30 amp fuse Battery power - spare9. BATTERY 2 20 amp fuse Battery power - spare10. RADIO 10 amp fuse Ignition power for radio11. GAUGES 20 amp fuse Ignition power for gauges

CIRCUIT# CIRCUIT RATING FUNCTION

12. ACCESSORY 1 30 amp Accessory power - spare13. PARK 15 amp Battery power for park lamps14. WIPER 20 amp Accessory power for wiper circuit15. HEAT/AC 30 amp Accessory power for heater circuit16. HORN OUT Relay power to horn (Battery)

Relay trigger ground from horn switch17. HORN SWITCH30 amp

20 amp20 amp

Power from Relay 218. RELAY 2 OUTTrigger for Relay 2 (Key or Battery)19. RELAY 2 POSITIVEGround trigger for Relay 220. RELAY 2 GROUND12 volt feed for hazard switch (Battery)21. HAZARD12 volt feed for turn switch (Keyed)22. TURN

Page 1

510488MADE IN THE U.S.A.

40 AMP RELAY

BA

TT

ER

Y 1

IGN

ITIO

N 2

HE

AD

LTS

IGN

ITIO

N 1

BA

TT

ER

Y 2

RA

DIO

RE

LA

Y 1

GA

UG

ES

ST

OP

/DO

ME

ACC

ESSO

RY 1

PA

RK

WIP

ER

RE

LA

Y 2

HE

AT

/AC

Page 2: HEADLTS IGNITION 1 PARK WIPER RELAY 2 HEAT/AC LED TURN

Page 2

USING THE SCREW DOWN CONNECTION BLOCKS

.150 max.

A screw driver is provided in this kit for use with our connection blocks. If you use any other screwdriver, please be sure that the tip is not wider than .150 inches.

.375(3/8")

Strip the wire to a length of 3/8". Use the strip gauge on the end blocks as a guide.

Loosen the cavity set screw to the fully open position. Insert the wire into the open cavity (be sure that all of the wire strands are inserted in the cavity), and tighten the set screw as shown. As the set screw and clamp are steel, the threads will not strip. If you are using a power screw tool that has a torque setting, install to 30 inch pounds. For wire removal, loosen screw and remove wire.

1 2

4

closed cavity

open cavity

wire

screwdriver

strip gauge

3 Note: The maximum wire size which can be installed into each cavity is one 12 gauge wire. Wires can be doubled in the cavity, but the maximum double is two 14 gauge wires.