Survey Area: S urve y U nit: PSA 01-02, 12/3/20 I 5 PageP-1 of6 PSA 01 02 HDP-PR-FSS-701, Final Stat us Survey Plan Development (Revision 9) APPENDIX P-3 FSSPLAN Description: Pipi ng Survey Area Bldg 1 I 0 SE (STM-2) Description: Storm Water piping SE of Bldg 110 Overview: The Survey Unit (SU) identified as PSA 0 l-02 (STM-2) has been prepared for Final Status Survey (FSS) by the Hematite Decommissioning Project (HOP). This appendix provides an overview of the proposed FSS implementation as well as general and specific instructions for the tech ni cians responsible for performing the FSS. Data Quality Obj ect ives I. Personnel performing FSS duties meet the qualifications listed in HDP-PR-HP-102 Health Physics Technician Training and have received training and instruction commensurate with their duties. The RSO has approved all FSS personnel to perform work associated with their individual rol es and responsibilitie s. Training records are documented in accordance with HDP-PR-GM-020, Training Material Development and Documentation of Training. 2. All HOP FSS procedures ("700 series") and the Final Status Survey Plan for Piping, HDP-PO-FSS- 800 have been reviewed, revised, and validated in order to ensure perfonnance of actual FSS work activities reflect the requirements detailed in the individual FSS Procedures and the HDP Decommissioning Plan. 3. All FSS in strumentation has undergone a receipt inspection by HDP QA personnel, is within current calibration, and is determined to be functioning within acceptable ranges based on initial set-up and daily source checks in accordance with HDP-PR-HP-411 , Radiological Instrumentation. HP tech ni cians will confirm that environmental conditions (e.g. operating temperature range, no wet surfaces) are acceptable for use of field instrumentation. Location PSA 01-02 is designated Class 1 and is comprised of 170 feet of 12" diameter piping and 10 I feet of 18" piping designated as STM-2 which is located to the South/Southeast of Bldg 110 (See Figure 1). The piping runs from a grated inlet (MH- 18) to the SE of bldg. 110 and continues approximately 271 feet (82.6 meters) to the south/southwest of building 110, STM-1 piping intersects with the STM-2 piping at MH-25. The piping associated with PSA 01-02 is contained within Land Survey Areas (LSA) LSA 06-01, LSA 08-03, LSA 08-04, and LSA 08- 16. The total surface area of PSA 0 1-02 is 94 m 2 Background This PSA survey unit was not specifically described in the DP. However, poential survey units for piping were described in HDP-PO-FSS-800 "Final Status Survey Plan for Piping". PSA 01-02 is a portion of the Storm Water Drain System that co llected run off water and directed the run off water to the site pond at outfall #3. The Storm HOP Site View: See PSA 01-02 Red (SEof Bldg 110) Water Drain System is designated as Class 1 survey area and the pulic supplied water systems which are designated as Class 3. Prior to final status survey the piping was washed out to remove any debris and sediment, a visual inspection was performed to ensure the piping was ready for FSS. The potential Quality Record

Upload: others

Post on 09-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • S urvey Area: Survey Unit:

    PSA 01-02, 12/3/20 I 5 PageP-1 of6

    PSA 01

    02

    HDP-PR-FSS-701, Final Status Survey Plan Development (Revision 9) APPENDIX P-3

    FSSPLAN

    Description: Piping Survey Area Bldg 1 I 0 SE (STM-2)

    Description: Storm Water piping SE of Bldg 110

    Overview: The Survey Unit (SU) identified as PSA 0 l-02 (STM-2) has been prepared for Final Status Survey (FSS) by the Hematite Decommissioning Project (HOP). This appendix provides an overview of the proposed FSS implementation as well as general and specific instructions for the technicians responsible for performing the FSS.

    • Data Quality Objectives

    I. Personnel performing FSS duties meet the qualifications listed in HDP-PR-HP-102 Health Physics Technician Training and have received training and instruction commensurate with their duties. The RSO has approved all FSS personnel to perform work associated with their individual roles and responsibilities. Training records are documented in accordance with HDP-PR-GM-020, Training Material Development and Documentation of Training.

    2. All HOP FSS procedures ("700 series") and the Final Status Survey Plan for Piping, HDP-PO-FSS-800 have been reviewed, revised, and val idated in order to ensure perfonnance of actual FSS work activities reflect the requirements detailed in the individual FSS Procedures and the HDP Decommissioning Plan.

    3. All FSS instrumentation has undergone a receipt inspection by HDP QA personnel, is within current calibration, and is determined to be functioning within acceptable ranges based on initial set-up and daily source checks in accordance with HDP-PR-HP-411 , Radiological Instrumentation. HP technicians will confirm that environmental conditions (e.g. operating temperature range, no wet surfaces) are acceptable for use of field instrumentation.

    • Location

    PSA 01-02 is designated C lass 1 and is comprised of 170 feet of 12" diameter piping and 10 I feet of 18" piping designated as STM-2 wh ich is located to the South/Southeast of Bldg 110 (See Figure 1). The piping runs from a grated inlet (MH- 18) to the SE of bldg. 110 and continues approximately 271 feet (82.6 meters) to the south/southwest of building 110, STM-1 piping intersects with the STM-2 piping at MH-25. The piping associated with PSA 01-02 is contained within Land Survey Areas (LSA) LSA 06-01, LSA 08-03, LSA 08-04, and LSA 08-16. The total surface area of PSA 0 1-02 is 94 m2•

    • Background

    This PSA survey unit was not specifically described in the DP. However, poential survey units for piping were described in HDP-PO-FSS-800 "Final Status Survey Plan for Piping". PSA 01-02 is a portion of the Storm Water Drain System that collected run off water and directed the run off

    water to the site pond at outfall #3 . The Storm HOP Site View: See PSA 01-02 Red (SEof Bldg 110) Water Drain System is designated as Class 1 survey area and the pulic supplied water systems which are designated as Class 3. Prior to final status survey the piping was washed out to remove any debris and sediment, a visual inspection was performed to ensure the piping was ready for FSS. The potential

    Qual ity Record

  • PSA 01-02, 12/3/20 15 Page P-2 of 6

    HDP-PR-FSS-701, Final Status Survey Pla n Development (Revision 9) APPENDIX P-3

    FSS PLAN

    exists for residual radioactivity within the piping to represent a significanl fraclion of the St rucrures. ' Systems, and Components (SSC) DCGL of 18,925 dpm/100 cm· .

    PSA 01-02 has not yet undergone a full final remedial action support survey. however preliminary surveys indicate that it is similar in nature to the condition of PSA 02-01 (SAN-I), so the FSS results collected from PSA 02-01 will be used for the purposes of developing a FSS plan for PSA 0 1-02. PSA 02-0 I underwent FSS during November, 20 15, including a scan of the bottom section of the accessible piping and 15 systematic total surface contamination (TSC) measurements. Swipe samples were collected at the accessible openings of the piping system.

    All direct measurement activities collected during the FSS of PSA 02-01 were well below the applicable SSC DCGL (with a maximum measurement at 9.6% of the DCGL) and removable activity was less than l % of the measured total activity results. This data supports the initial DP Classification of Class l for PSA 02-0 I, and is considered similar in nature to the current status of PSA 01-02.

    The Jsolation and Control (I & C) postings (signage) have been placed on each access grating or manhole for this section of piping.

    • Criteria

    All FSS analytical results for measurements/samples collected within PSA 01-02 will be evaluated against the HOP SSC Gross Activity DCGL of 18,925dpm1100 crn2•

    Radionuclide ..,

    Structural Surfaces (dpm I 100 cm-)

    Total Gross Activity 18,925

    Table adapted fron1 HOP FSS Procedure HDP-PR-FSS-701. Final Status Survey Plan Development, Revision 7, June 20 15.

    • [mplem entatio n

    PSA 01-02 wi ll undergo scan of the bottom section of the piping of all accessible su1faces using a Ludlum 43-68 gas flow propo1t ional detector. This scan survey w ill be perfonned remotely with the probe mounted on a remote controlled vehicle that can be moved through the piping at the appropriate speed.

    Static biased measurements wi ll be collected at locations where remediation at locations that exceed the investigation action level identified during the scan surveys and at any areas designated in the survey instructions.

    Based on a statistical evaluation of the RASS dataset, a minim um of eleven ( 11) measurement locations were calculated fo r PSA Ol-02 and 15 locations were designed . As the BSA is a Class 1 survey unit, the 15 measurement locations were selected based on a random-start point and then even ly spaced w ithin the section of piping. Direct measurement locations for the exposed surfaces are specified in the distance in feet from the starting point of the piping system specified in the survey figu re and on Appendix P-4.

    Cloth smears will be swiped with moderate pressure over an area of 100 cm2 (a 4" by 4" square) in an S-shaped pattern in order to assess removable activity at each accessible opening.

    Quality Record

  • PSA 0 1-02, 12/3/2015 Page P-3 of 6

    HDP-PR-FSS-701 , Final Status Survey Plan Development (Revision 9) APPENDIX P-3

    FSSPLAN

    Per HDP-PR-FSS-703 , QC replicate survey requirements for structural survey units require that 5% of all C lass I , C lass 2, and C lass 3 SSC Survey Units are randomly selected to undergo a replicate survey of the entire SU area. The replicate survey is to be performed by an l IP technician other than the one who performed the initial survey using similar instrumentation. PSA 01-02 is not one of the randomly selected Class l Survey Units for which a replicate survey has been required.

    FSS IMPLEMENTATION SUMMARY TABLE

    Portable Instrument Scanning: Scan Coverage Bottom portions of PSA 01-02 Scan MDC 1,868 dpm / 100 cm1 (Ludlum43-68) Inves tigation Action Level (lAL): general area 9,463 dpm I I 00 cm1 (50% of the DCGL)

    Total Surface Contamination (TSC) Measurements: Surface Minimum Number of Comments

    Measurements A total of 1 l TSC measurements

    Bottom surface of piping 15 locations have been systematically des igned from a random start point.

    Removable Activity Locations:

    Using moderate pressure swipe a cloth smear over the surface (e.g. exterior wall, roof, window, etc.) in an S-shaped pattern within an approximately 4" by 4" box at each access point to the piping system. More than one smear may be collected at each access point.

    Biased Measurement Locations: Perfonn static biased measurements at locations that exceed the IAL and at any locat ion where visual inspection has identified cracks or breaks in the piping.

    Instrumentation

    Ludlum 2360 with 43-68 scintillation detector; Used for scanning and to obtain static (TSC) measurements.

    Tennelec or Ludlum 3030 with 43-10-1 scinti llation Used for counting of swipe (smear) detector samples.

    Quality Record

  • PSA 01 -02, 12/3/2015 Page P-4 of 6

    RDP-PR-FSS-701, F inal Status S un1ey Pla n Develo pment (R evision 9) APPENDIX P-3

    FSS PLAN

    General Ins tructions:

    I. Summarize daily work activities on the log sheets provided in Appendix P-6 (from procedure HDP-PR-FSS-701 , Final Status Survey Plan Development). Provide a description of work area conditions, measurements collected (including swipes for removable activity) and the status of instrument scan surveys for every shift that involves work in this survey unit. Document the surveyor name and instrumentation used for each structural suiface survey on Appendix A-1 (from procedure 1-lDP-PR-FSS-712, Final Status Surveys of Structures, Systems, and Components) and on Appendix P-6 for reporiing traceability. In the event that a situation arises where the survey instructions cannot be followed as written, stop work and contact the FSS Supervisor for resolution. All changes to the survey instructions shall be approved by the RSO before continuing work and be documented in the FSS Field Log.

    2. Jn accordance with HDP-PR-FSS-701, (Sec. 8.4.2), documentation of activities performed, equipment used, and potential safety hazards that may be encountered during the performance of characterization activities (along with associated controls) will be documented using the FSS Daily Task Briefing log sheet.

    3. Confirm that isolation controls (I & C) are in effect before FSS commences.

    4. In accordance with HDP-PR-HP-4 l l, Radiological Instrumentation, confirm that FSS instrumentation is within the current calibration period, has been daily source checked, and environmental conditions are acceptable for field use as per the manufacturer's recommended operating parameters. As required by HDP-PR-HP-415, Operation of the Ludlum 2350 or 2360 for Final Status Survey, calculation of weighted efficiencies for each survey detector used during FSS of PSA 01-02 wi ll be perfonned prior to field use.

    5. Structural FSS are to be performed in accordance with HDP-PR-FSS-712, Final Status Surveys of Structures, Systems, and Components, using instrumentation that has been documented and prepared per the requirements of HDP-PR-HP-411 and HDP-PR-HP-415. PSA Ol -02 is a Class I Survey Unit. A total of 15 systematic TSC measurements will be taken across the entire survey unit. the survey un it will be scanned by remote access on the bottom surfaces of the piping using a Ludlum 43-68 gas flow proportional detector

    6. A scanning survey of the accessible bottom surfaces of the piping will be performed using a Lud lum 43-68 gas flow proportional detector. Move the cart holding the probe across the bottom surface of the piping at a speed between 1 and 2 inches per second while ensuring the probe is as close (nominally W', but not to exceed Yi") to the surface as conditions allow. Due to the large diameter of the pipe the curvature of the pipe bottom is not expected to cause counting geometry issues, however if it is observed that the probe exceeds the maximum Y2" distance, an adjusted efficiency will be calculated using the Source to Detector Distance Effects specified in Appendix A of HDP-PO-FSS-800. The scanning surveys will cover the bottom portions of the piping in accessible areas within the entire of interest as indicated in the table above. Notify the FSS Supervisor of any areas, conditions or constraints where surveying (or subsequent TSC) may not be possible. Document the conditions and any resolutions in the FSS Field Log.

    7. Perfonn static biased measurements at any locations that exceed the IAL or are specified in the specific survey instructions. Consult FSS supervision for guidance on the amount and specific locations of biased measurements.

    8. Static TSC measurements made with the scaler-ratemeter (Ludlum 2360) coupled to the Ludlum 43-68 detector will be logged electronically. Results of the piping survey wi ll be documented on fonn Appendix A-I from HDP-PR-FSS-712.

    9. A map or diagram of the piping survey area will be attached to the survey instruction. Direct measurement locations are given in distance in feet from the east end of the pipe.

    Qua I ity Record

  • PSA 0 1-02, 12/3/20 1 5 Page P-5 of 6

    HDP-PR-FSS-701, Final Status Survey Plan Development (Revision 9) APPENDIX P-3

    FSSPLAN

    I 0. Swipe samples wi 11 be collected at each accessible opening of the pipe. All swipe samples will be analyzed in the onsite laboratory using the Tennelec or the Ludlum 3030 swipe counters for gross alpha/gross beta activity.

    I I. No volumetric sampling is planned as part of the FSS effort for PSA 01 -02.

    Specifi c Instructions:

    NOTE: Unless otherwise indicated, the performance of these specific instructions is the responsibility of the HP Technician.

    Before Beginning Work

    1. Rad. Engineer/HP Technician: Perform a daily task-specific briefing; documenting the attendants, planned work activities, anticipated hazards, and controls on the FSS Daily Task Briefing log sheet.

    2. Rad. Engineer/HP Technician: Verify that survey instrumentation is within the current calibration period by checking the calibration due date for each piece of instrumentation used for FSS. Perform daily pre-and post-survey daily source checks for handheld survey instrumentation in accordance with HDP-PR-HP-411. Confinn that environmental conditions in which the survey will be performed are within the manufacturer's recommended operating range (e.g. temperature between -4° F to 122° F).

    3. Rad Engi neer/HP Technician: Prior to survey, collect three background measurements in (alpha+ beta) scaler mode at waist level per Step 8.4.1 of HDP-PR-FSS-712. Use the average of the three readings as the daily field background. The purpose of these measurements is to determine the ambient background count rate and identify a previously undetected source term within or near the survey area.

    4. Rad. Engineer/HP Technician: Prior to survey, inspect the work area to ensure that the su1face is clean and dry and ensure the visual inspection has been completed.

    Structural Su rveys (Scanning, Total Sur-face Contamination Direct Measurements, Swipes)

    I. It is not necessary to establish a "material background" for the surface being surveyed, since all measurements will be compared to the gross activity SSC DCGL of l 8,925 dpm I I 00 cm2.

    2 . Perform a scan of the piping surface maintaining the probe as close to the surface as conditions allow (nominally 1/4", but not to exceed 1/2") moving the probe at a rate between I and 2 inches per second, in accordance with 1-lDP-PR-FSS-712 and H DP-PR-HP-415.

    a. Look and/or listen for elevated count rates and then pause to detennine locations that exhibit anomalous readings (e.g., count rates that exceed the IAL for this unit).

    b. Document the location(s) exhibiting anomalous readings to facilitate possible future investigations by annotating the distance in the pipe and relative position (e.g bottom).

    3. At each location where anomalous readings occur, perform a more detailed point survey of the area. Pause and place the survey probe in the area of the readings to define and record the total count rate associated with the area of interest on the Field Log. If residual radioactivity exceeding the static MDA is detected at any special features of concern (cracks, crevices, seams, joints, small holes, penetrations), contact FSS supervision for guidance. Adjustments in instrument efficiency or volumetric sampling may be necessary.

    4. Collect static count measurements at the 15 systematically designed locations on contact with the structural surface for a period of l minute.

    5. At each accessible opening in the pipe, swipe a cloth smear over the surface (e.g. interior wall, ceiling, etc.) with moderate pressure in an S-shaped pattern within an approximately4" by 4" box (100 cm2).

    6. Record all scan, direct measurements, and swipe data on Form Appendix A-1 and submit to the FSS

    Quality Record

  • PSA 0 l -02, 12/3/20 I 5 Page P-6 of 6

    HDP-PR-FSS-701, Final Status Survey Plan Development (Revision 9) APPENDIX P-3

    FSSPLAN

    Supervisor for review.

    Volumetric Sampling

    1. No volumetric sampli ng is planned as part of the FSS of PSA 01-02.

    / ~ Prepared by: Greg Peterschmidt (Print Name) ' (Sigrf'ure)

    Peer Reviewed by: Scott Zoller Gcqi(L (Print Name)

    Approved by (,J ~ (RSO): W. Clark Evers (Print Name) (Signature)

    Quality Record

    rz...[ ~Lrs-(Date)

    1~h'~--(Dae)

    IZ-/ 3/ ; S (Date)

  • Procedw·e: HDP-PR-FSS-701 , Final Status Survey Plan Development Hematite

    Decommissioning Project rs.

    APPENDIX P-2

    . I I

    I

    FINAL STATUS SURVEY SAMPLING PLAN DEVELOPMENT CHECKLIST FOR STRUCTURE SURVEY UNITS

    Survey Area PSA 0 I Description: Piping Survey Area Bldg 110 SE (STM-2)

    Survey Unit 02 Description: Storm Water piping SE of Bldg l l 0

    1. Survey Unit Isolation & Control

    Has the Survey Unit been properly isolated and/or controlled (indicated by marking the area with posting the appropriate signage) as required by HDP-PR-HP-602, Data Package Development and Isolation and Control Measures to Support Final Status Survey?

    Yes [gJ No D

    (If ·'No'', then discontinue survey design until area turnover requirements have been met).

    Signs placed on piping access points.

    2. Assessm ent of Characterization/Remedial Action Support Surveys (RASS)

    a. Derive & List the Basic Statistical Data for the TSC measurements in the characterization/RASS Survey Population.

    # of Measurements Taken:

    TSC Measurements

    (dpm/ 100cm2)

    Minimum 0

    Maximum 1811

    Mean 928

    Median 1133

    Standard Deviation 572.5

    b. Is the characterization/RASS Survey Data sufficient to support FSS Design? Yes~ No D

    PSA 01-02

  • Procedure: HDP-PR-FSS-701 , Final Status Survey Plan Development Hematite

    Decommissioning Project Revision: 9 Appendix P-2,

    Page 2of8 YOU.

    APPE NDIX P-2 FINAL ST A TUS SURVEY SAMPLING PLAN DEVELOPMENT CHECKLIST FOR

    STRUCTURE SURVEY UNITS

    ( If "No", then terminate survey design and perform additional characterization or remediation and repeat the

    planning process.

    3. Survey Unit Classification

    Write a short description of the survey unit based on historical use and remedial activities:

    PSA 01-02 includes the interior surfaces of the 12" diameter storm piping that runs from a grated inlet to the SE of bldg. 110 and continues approximately 271 feet (82.6 meters) to the south/southwest of building 1l0 were Storm Water 2 piping intersects with the piping. The total surface area of PSA 0 1-02 is approximately 94.0 m2. Jt is classified as a MARSS IM Class I survey unit.

    Initial Classification per DP Ch 14: Survey Unit Area: 94.0 m~

    a. Has the Survey Unit C lassification changed from the Initial Classification for the Survey Unit as described in DP Ch. 14?

    Yes 0 No (8J

    (If ·'Yes", then include a copy of Appendix P-5, Survey Unit Classification Change Form with the FSSP).

    b. Is the Survey Unit area less than the maximum size for the Classification? Yes [8] No D (If '·No", then terminate survey design and evaluate dividing the survey unit into multiple survey units).

    4. Area Remediation

    Select the appropriate remediation status for the Survey Unit.

    0 No Remediation 0 System Removal

    [8J Structural or System Decontamination 0 Structural Removal

    PSA 01 -02

  • Procedure: HDP-PR-FSS-701, Final Status Survey Plan Development Hematite

    ·. I Decommissioning I Appendix P-2, Project ' Page 3of8

    I ~ : I l agreement I you. -APPENDIX P-2

    FINAL STATUS SURVEY SAMPLING PLAN DEVELOPMENT CHECKLIST FOR STRUCTURE SURVEY UNITS

    S. Types of Samples and Measurements for FSS

    Select the appropriate types of samples and measurements for FSS for this Survey U nit.

    Statistical Sample Population

    rgj Total Surface Contamination (TSC) measurements.

    rgj Swipe Samples for Loose Surface Contrunination.

    0 Volumetric Material Samples

    0 Other

    Scan Measurements

    0 1 00% Scan Coverage of Exposed Surfaces.

    ~ See note % Scan Coverage of Exposed Surfaces.

    Note: Scanning will be performed remotely on the bottom portions of the piping as these are the most likely to be contaminated and at any locations identified during the visual inspection as specified in the special instructions

    in the FSS Plan.

    6. Derived Concentration Guideline Levels (DCGL)

    The Adjusted Gross DCGL for structural surfaces at HOP is 18,925 dpm/ 100cm2 per Table 14-7 of DP Ch. 14. This Table has been reproduced as Appendix C of HDP-PR-FSS-701.

    7. Determine the Number of Samples in the Statistical Survey Population

    a. Set the Lower Bound of the Grey Region (LBGR) at the mean activity for the characterization/RASS survey data set from Step 2.

    ActivityMean = 928 dpm/l00cm2 =Lower Bound of the Grey Region (LBGR)

    b. Standard Deviation for the characterization/RASS survey data set from Step 2.

    cr = 572.5

    c. Define the Decision E1Tors.

    Type l Error = 0.05 Type II Error = 0. I 0

    Note: The Type I I Error is set at 0. 10 initially but it may be adjusted with RSO concurrence.

    PSA 01-02

  • Procedure: HDP-PR-FSS-70 I, Final Status Survey Plan Development Hematite

    Decommissioning Project

    -

    APPENDIX P-2

    Revision: 9 Appendix P-2, Page 4 or 8

    FINAL STATUS SURVEY SAMPLING PLAN DEVELOPMENT CHECKLIST FOR STRUCTURE SURVEY UNITS

    d. Determine the Relative Shift using the equation from Step 8.3.4c of HDP-PR-FSS-701.

    Relative Shift = 31.4

    e. Is the Relative Shift between 1 and 3? Yes 0 No~

    (Jf"Yes", then continue to Step 7f, if "No", then proceed to the next step).

    1f the variability in the data set is acceptable, then adjust the LBGR as necessary in order to ach ieve a Relative Shift between l and 3. ln order to accomplish this, the LBGR may be set as low as the MDC of the instrument that will be used for the measurements.

    Adjusted LBGR = 17,207

    Adjusted Relative Shift = 3.0

    f. Determine the Number of Samples (N) required corresponding to the Type I error, Type II Error and the Relative Shift from Appendix E ofHDP-PR-FSS-701.

    Number of Samples (N) = 11

    8. Determine the Scan MDC

    a. Identify the Radiological Instrument that will be used for scanning.

    0 Ludlum 43-89 Scintillation Detector Other Ludlum 43-68 Gas Flow Proportional Detector

    b. Determine the Scan MDC for the selected instrument using the equation from Step 8.3.Sb of HDP-PR-FSS-701.

    MDCscan = 1,868 dpm/ 100cm2

    9. Adjust the Statistical Sample Population Size (N) for Scan MDC

    a. Is the MDCscan for the selected instrument less than the Adjusted Gross DCGL? Yes f.8] No D

    PSA OJ.02

  • Hematite Decommissioning

    Project

    Procedure: HDP-PR-FSS-701 , Final Status Smvey Plan Development

    Revision: 9

    APPENDIX P-2

    Appendix P-2, Page 5 of 8

    FINAL STATUS SURVEY SAMPLLNG PLAN DEVELOPMENT CHECKLIST FOR STRUCTURE SURVEY UNITS

    b. lf the answer to the question in Step 9a is ·'Yes" or the survey unit is either Class 2 or Class 3, then proceed to Step I 0. If the answer to the question in Step 9a is ''No" and the survey unit is Class 1, then proceed to the next step.

    c. Divide the total area of the smvey unit by the Number of Samples (N) calculated in Step 7f to calculate the area bounded by the statistical sample population (Asu).

    Area Bounded by the statistical sample population (Asu) = NIA m2

    d. Select an Area Factor (AF) from Appendix I of HDP-PR-FSS-701 that corresponds to the area bounded by the statistical sample population (Asu).

    AF for the Bounded Area (Asu) = NA

    e. Multiply the Adjusted Gross DCGL Area Factor (AF) to derive an Adjusted Gross DCGLEMC·

    Adjusted Gross DCGLEMC = NA dpm/ I 00cm2

    f. ls the MDCscan for the selected instrument less than the Adjusted Gross DCGLEMc?

    Yes D No D NA l25J

    g. If the answer to the question above is ''Yes", then continue to Step 10. If the answer to the question above is "No", then proceed to the next step.

    h. Determine a new AF (AfEMc) corresponding to the MDCscan for the selected instrument by dividing the MDCscan by the Adjusted Gross DCGLw.

    AF EMC COtTesponding to MDCscan = NA

    1. Find the Area (A' ) that corresponds to the Area Factor (AF EMc).

    A' corresponding to AF EMC = NA

    Note: The Area Factors for structures are found in Appendix I of HDP-PR-FSS-70 L.

    J. Determine an Adjusted Number of Samples (NEMC) for the statistical sample population size that corresponds to the bounded A EMC using the equation from Step 8.3.6h of HDP-PR-FSS-701.

    NEMC corresponding to A' = NA

    PSA 01-02

  • Procedure: HDP-PR-FSS-701, Final Status Survey Plan Development Hematite

    Decommissioning Project Revision: 9

    Appendix P-2, Page 6of8

    APPENDIX P-2 FINAL STATUS SURVEY SAMPLING PLAN DEVELOPMENT CHECKLIST FOR

    STRUCTURE SURVEY UNITS

    N calculated in Step 7f = NA

    k. Is NEMC > the value ofN determined in Step 7f? Yes D No D NA~

    (If "Yes", then use the larger NEMC value as the statistical sample population size. If no, then use the value of

    N that was calculated in Step 7f as the statistical sample population size).

    10. Determine the Grid Spacing

    a. Is the Survey Unit a Class 3 Survey Unit? Yes D No~

    (If •·Yes", then continue to Step 11, if ·'No'', then proceed to the next step).

    b. Determine Grid Spacing (L) using the equation from Step 8.3.7b of HDP-PR-FSS-701. For piping systems determine the spacing in accordance with Step 8.3.7c of HDP-PR-FSS-701

    Grid Spacing (L) for Survey Unit = 5.51 * m

    *Minimum number of 11 samples calculated, 15 systematic samples were designed.

    11. Generate a Survey Map

    a. Assign a unique identification number to each measurement in the statistical sample population using the guidance and direction provided in Appendix M of HDP-PR-FSS-701.

    b. Generate a graphic representation of the Survey Unit with dimensions and boundaries corresponding to an established reference coordinate system in accordance with Step 8.3.8 of HDP-PR-FSS-701.

    c. Using the reference coordinate system, ascertain coordinates for each sample location.

    d. Designate measurement locations, and location coordinates on Appendix P-4, FSS Sample & Measurement locations & Coordinates and attach a copy of that form to the FSSP.

    e. Attach a copy of the developed Survey Map with sample locations to the FSSP.

    12. Biased Measurements

    a. Designate if any biased measurements will be taken at the discretion of the HP Staff designing the survey and the basis for taking them. Necessary biased samples will be explained on Appendix P-3, FSS Sampling Plan.

    PSA 01-02

  • Hematite Decommissioning

    Project

    Procedure: HDP-PR-FSS-701. Final Status Survey Plan Development

    Revision: 9

    APPENDIX P-2

    Appendix P-2. Page 7of8

    FINAL ST A TUS SURVEY SAMPLING PLAN DEVELOPMENT CHECKLIST FOR STRUCTURE SURVEY UNITS

    ote: Biased measurements are not included as pan of the statistical sample population. Rather. they are treated as pre-emptive investigation measurements.

    b. Using lhc reference coord inate system, ascertain coordinates for each biased measurement location.

    c. Designate biased measurement locations, and location coordinates on attached Appendix P-4, FSS Sample & Measurement Locations & Coordinates.

    13. Scan Coverage

    a. The urvey Unit is: ~ Class I D Class 2 D Class3

    b. Based on the Survey Unit Classification. the scan coverage in this Survey Unit is:

    D I 00% Scan Coverage of exposed surface See Note % Scan Coverage of exposed surface

    1ote: Scanning will be perfonned remotely on the bottom portions of the piping as these are the most likely to be contaminated and at any locations identified during the visual inspection as specified in the special instructions in the FSS Plan.

    14. Investigation Levels

    a. The Survey Unit is: D Class 3

    I) Scan Investigation Levels are set at the most limiting between the Adjusted Gross DCGLw = 18,925 dpm/ I 00cm2 or the MDCscan for the instrument used.

    2) TSC Measurement Investigation Levels are set at 50% of the Adjusted Gross DCGL" = 9,462 dpm/ I 00cm2.

    b. The Survey Unit is: D Class 2

    I) Scan Investigation Levels are set at the most limiting between the Adjusted Gross DCGL_, = I 8,925 dpm/ I 00cm2 or the M DCscan for the instrument used.

    2) TSC Measurement Investigation Levels are set at the Adjusted Gross DCGLw = I 8,925 dpm/ l 00cm2•

    PSA 01-02

  • Procedure: HDP-PR-FSS-701, Final Status Survey Plan Development Hematite

    Decommissioning Project

    APPENDIX P-2

    Revision: 9 Appendix P-2, Page 8of8

    FINAL STATUS SURVEY SAMPLING PLAN DEVELOPMENT CHECKLIST FOR STRUCTURE SURVEY UNITS

    c. The Survey Unit is: 1:8'.1 Class I

    1) Scan lnvestigation Levels (general area) are set at 50% of the Adjusted 9,463 dprn/100cm2

    Gross DCG Lw =

    2) TSC Measurement Investigation Levels are set at the Adjusted Gross DCGLw = 18,925 dpm/ JOOcm2•

    15. FSSP Development Checklist Approval

    Prepared by: Greg Peterschmidt rt. .. f:1(cr (Print Name) (Date)

    Peer Reviewed by: Scott Zoller

    (Print Name)

    Approved by (RSO): W. C lark Evers 12/J/; s (Print Name) (Signaturt:) (Date)

    PSA 01-02

  • Procedure: HDP-PR-FSS-701, F inal Status Survey Plan Development

    Hematite I

    Decommissioning Project Revision: 9 Appendix P-4, Page l of l

    I

    APPENDIX P-4 FSS SAMPLE & MEASUREMENT LOCATIONS & COORDINATES

    Survey Area: PSA 01 Description: Piping Survey Area Bid 110 SE (STM-2) Survey Unit: 02 Description : Storm Water piping SE of Bid 110 Survey Type: FSS Classification: Class l

    Measurement or Sample Surface or Type

    Start* End* Feet Southwest Feet East Remarks I Notes

    ID CSM Elevation Elevation from MH-18

    PO 1-02-0 I -S-O-S-00 0 s NA NA 11 NIA STM-2 Int. Bottom PO 1-02-02-S-O-S-OO 0 s NA NA 29 NIA STM-2 Int. Bottom PO l -02-03-S-O-S-OO 0 s NA NA 47 NIA STM-2 Int. Bottom PO 1-02-04-S-0-S-OO 0 s NA NA 65 NIA STM-2 Int. Bottom PO 1-02-05-S-O-S-OO 0 s NA NA 83 NIA STM-2 Int. Bottom POl-02-06-S-O-S-OO 0 s NA NA IOI NIA STM-2 Int. Bonom PO 1-02-07-S-O-S-OO 0 s NA NA 119 NIA STM-2 Int. Bottom PO 1-02-08-S-O-S-OO 0 s NA NA 133 NIA STM-2 Int. Bottom PO 1-02-09-S-O-S-OO 0 s NA NA 155 NIA STM-2 Int. Bottom PO 1-02-1 O-S-O-S-00 0 s NA NA 173 NIA STM-2 Int. Bottom PO 1-02-11-S-O-S-OO 0 s NA NA 191 NIA STM-2 Int. Bouom PO 1-02-12-S-O-S-OO 0 s NA NA 209 NIA STM-2 Int. Bottom POl-02-13-S-O-S-OO 0 s NA NA 227 NIA STM-2 Int. Bottom PO 1-02-14-S-O-S-OO 0 s NA NA 245 NIA STM-2 Int. Bottom PO l-02-15-S-O-S-OO 0 s NA NA 263 NIA STM-2 Int. Bottom

    *Elevations are in feet above mean sea level. **Missouri - East State Plane Coordinates [North American Datum (NAD) 1983] (Open Land Area): OR Distance in feet from lower left comer of!hc surface (Strucrures): each surface has it's ovm (X, Y) = (0,0); OR For piping tl1e disranct: from tlle beginning of the survey unit. Surface: Floor = F; Wall = W: Ceiling = C: Roof= R: Other=O CSM: Three-Layer (Surface-Root-Deep) or Unifonn Type: Systematic = S, Biased = B: QC =Q: Investigation = I

    Quality Record

  • Procedure: HDP-PR-FSS-701 , Final Status Survey Plan Development Hematite

    Decommissioning Appendix P-6,

    Project Revision: 9 Page I of 1

    APPENDIX P-6 FSS FIELD LOG

    Survey Area: Description:

    Survey Unit: Description:

    FSS Field Log:

    Date/Time: Observation or Comment: Technician

    FSS Field Log _ of -

    Oualitv Record

  • Distance

    Survey Unit Sample ID from Southwest

    end of pipe

    PSA-01-02 POl-02-01-S-O-S-OO 11 ft .

    PSA-01-02 POl-02-02-S-O-S-OO 29 ft .

    PSA-01-02 POl-02-03-5-0 -S-OO 47ft.

    PSA-01-02 POl-02-04-S-O-S-OO 65 ft .

    PSA-01-02 POl-02-05-S-O-S-OO 83 ft .

    PSA-01-02 POl-02-06-S-O-S-OO 101 ft . "O x

    PSA-01-02 POl-02-07-S-O-S-OO 119 ft . E .,.; ;;; ~

    PSA-01-02 POl-02-08-S-O-S-OO 137 ft . ~

    d ro

    PSA-01-02 POl-02-09-S-O-S-OO 155 ft . ~ ~ 4> 2:

    PSA-01-02 POl-02-10-S-O-S-OO 173 ft. :> en

    PSA-01-02 POl-02-11-S-O-S-OO 191 ft .

    PSA-01-02 POl-02-12-S-O-S-OO 209 ft .

    PSA-01-02 POl-02-13-S-O-S-OO 227 ft .

    PSA-01-02 POl-02-14-S-O-S-OO 245 ft .

    PSA-01-02 POl-02-15-5-0 -5-00 263 ft.

    07-01

    BLDG 110

    BSA-01-01

    ~

    08-04

    I I I I

    /

    ' '

    ,, PO 1-02-03-S-O-S-OO

    L

    PO 1-02-04-S-O-S-OO

    PO 1-02-05-S-O-S-OO

    PO 1-02-06-S-O-S-OO

    08-03 P~07-S-0-S-OO

    PO 1-02-08-S-O-S-OO

    06-01

    PO 1-02-1 O-S-O-S-00

    PO 1-02-11-S-O-S-OO

    PO 1-02-1 2-S-O-S-OO

    08-16 PO 1-02-13-S-O-S-OO

    08-01

    PO 1-02-15-S-0-S-OO

    LEGEND:

    ® Sample Location

    PSA 0 1-02

    D LSA Boundaries Building

    C Haul Road - Fence

    0 10 20 30 Feet

    Requested B~ Document Reason C' Evers MDP-ENG 11-WP-OO