HEART RATE MEASUREMENT FROM FINGERTIP
![Page 2: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/2.jpg)
INTRODUCTION ► Heart rate measurement
indicates the soundness of the human cardiovascular system.
► This project demonstrates a technique to measure the heart rate by sensing the change in blood volume in a finger artery while the heart is pumping the blood.
![Page 3: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/3.jpg)
BASIC BLOCK DIAGRAM
![Page 4: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/4.jpg)
SYNOPSIS
► Heart rate measurement system that uses optical sensors to measure the alteration in blood volume at fingertip with each heart beat.
► sensor unit consists of an infrared light-emitting-diode (IR LED) and a photodiode.
► IR diode transmits an infrared light into the fingertip and the photodiode senses the portion of the light that is reflected back.
![Page 5: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/5.jpg)
► Intensity of reflected light depends upon the blood volume inside the fingertip.
► So, each heart beat slightly alters the amount of reflected infrared light that can be detected by the photodiode & with a signal conditioning this little change in the amplitude of the reflected light can be converted into a pulse which can counted by MC.
![Page 6: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/6.jpg)
SCHEMATIC
► The schematic consist of two stages:-
1. Input sensing and conditioning circuit.
2. MCU circuit used for counting of pulses & display of output.
![Page 7: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/7.jpg)
INPUT SENSING & CONDITIONING CIRCUIT
![Page 8: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/8.jpg)
MCU AND OUTPUT DISPLAY
![Page 9: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/9.jpg)
MAJOR COMPONENTS USED
► Pic16f628a (MCU):
1. By microchip technology.
2. Smaller instruction set as compared to other MCUs.(RISC based)
3. Low cost with high clock speed.
4. Provide wide range of interfacing.
![Page 10: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/10.jpg)
MAJOR COMPONENTS USED
► MCP602 transistor:
1. Dual package opamp from microchip.
2. Operating voltage-2.7-6V
3. Need Single supply voltage
4. Used in input signal amplification.
► Photodiode and IR diode as sensor unit
► 3 digit 7-segment display
![Page 11: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/11.jpg)
APPLICATIONS AND SIGNIFICANCE OF THE PROJECT
► This project aim at learning the compact and advanced medical technology used in measuring heart rate.
► The project has been widely applied in medical technology , even in heart rate monitoring applications designed for mobile phones.
![Page 12: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/12.jpg)
ESTIMATED COST & SCHEDULING ANALYSIS
► The complete project setup is costing in the range of Rs. 800 to 1000/- *.
► The entire project is scheduled in two phases:-
1. Learning of embedded C programming used.
2. Hardware implementation: Assembling the entire setup on PCB or PCB prototype board.
*(may subject to change due to faulty component of wear and tear).
![Page 13: Heart Rate Measurement From Fingertip2003](https://reader034.vdocument.in/reader034/viewer/2022051515/552c074b550346820f8b4648/html5/thumbnails/13.jpg)
THANK YOUSamarpit arya(07710102809)
Abhinav choudhary(07610102809)