heat loss in bare & lagged pipes presentation
TRANSCRIPT
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
1/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
2/15
To determine the combined radiation andconvection coefficient, hr + hc, at varioustemperatures from different surfaces.
Bare pipe
Painted pipe
Pipe with Silver chrome paint
Pipe with 85% magnesia insulation
To determine the Lagging Efficiency, L.E.
To compare the experimentally determined valuesof hc and hr with those calculated from empiricalequations.
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
3/15
Boiler
Test pipes
Bare pipe Painted pipe
Pipe with Silver chrome paint
Pipe with 85% magnesia insulation
Thermometers Beakers
Graduated cylinders
Stopwatch
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
4/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
5/15
Make three runs with steam at approximately 10 psi g, 20psig and 30 psig
For each run: After adjusting the system to the desired pressure, crack the
drain cock under the header to remove water from the steamline and header. Open the four plug type valves to blow out any condensate
from the pipes, and then close them until only a small amount ofsteam escapes along with the condensate.
When the system has reached equilibrium, as determined bysurface temperature measurements, collect and measure the
condensate from each pipe over a timed interval of 15 to 30minutes, and during this period record the following data: Barometric pressure Room temperature Steam pressure and temperature Surface temperatures
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
6/15
Surface temperatures should be taken at three ormore equally spaced points along each test pipe,and at least three sets of readings should be takenduring each run.
(NOTE: Because steam rising from the condensate valvestends to heat the pipes and insulation, no temperaturemeasurements should be made within 20 inches of the exitends of the pipes)
From the experimental data for each run, calculatethe combined film coefficients for convection andradiation and the lagging efficiencies.
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
7/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
8/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
9/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
10/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
11/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
12/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
13/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
14/15
-
8/13/2019 Heat Loss in Bare & Lagged Pipes Presentation
15/15
Fix the boiler and leaks.
Perform more experiments to be able to
acquire reasonable data.