heat pump mini split inverter - innovair · 2020. 8. 2. · heat pump mini split inverter w w w . i...

2
Vexus HEAT PUMP MINI SPLIT INVERTER www.innovair.com Key Features Wifi Ready Sleep Mode System will operate at a lower fan speed leading to a quieter operation autmatically TURBO Mode TURBO Mode will quickly cool or heat any area within a short period of time High Density Filters HD filters help to remove dust, bacteria, and allergens for a healthier environment Flexible Ambient Temperature Operations Cooling Mode can operate up to 122°F Heating Mode can operate as low as 4°F Dehumidifier System operates as a dehumidifier to help keep unwanted moisture out High Efficiency Solution Keep cool or stay warm with low electrical consumption

Upload: others

Post on 24-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • VexusHEAT PUMP MINI SPLIT INVERTER

    w w w . i n n o v a i r . c o m

    Key Features

    Wifi Ready

    Sleep Mode

    System will operate at a lower fan speed leading to a quieter operation autmatically

    TURBO Mode

    TURBO Mode will quickly cool or heat any area within a short period of time

    High Density Filters

    HD filters help to remove dust, bacteria, and allergens for a healthier environment

    Flexible Ambient Temperature Operations

    Cooling Mode can operate up to 122°FHeating Mode can operate as low as 4°F

    Dehumidifier

    System operates as a dehumidifier to help keep unwanted moisture out

    High Efficiency Solution

    Keep cool or stay warm with low electrical consumption

  • VexusM i n i S p l i t I n v e r t e r

    *Specifications are subject to changes without notice. ** Model numbers, pictures, and specifications of all products are subject to change without further notice.

    Distributed by :

    © 2017 Innovair Corporation. Todos Los Derechos Reservados.

    www.innovair.com INNVINH220A

    Connect with us on

    PERFECT APPLICATION FOR

    HOUSE STORE OFFICE

    ACCESSORIES INCLUDED• 16Ft Copper Kit• Inter-connecting cable kit• Installation Manual• Plastic cover for valves• LCD Wireless remote control

    w w w . i n n o v a i r . c o m

    MODEL VIN310H1V51 VIN310H2V51 VIN414H1V51 VIN414H2V51 VIN520H2V51 VIN625H2V51

    CAPACITY BTU/H 9,000 9,000 12,000 12,000 18,000 24,000

    ELECTRICAL Volt / Hertz 115V / 60Hz 208~230V / 60Hz 115V / 60Hz 208~230V / 60Hz 208~230V / 60Hz 208~230V / 60HzRated Current (A) 6.8 6.8 8.8 4.5 7.3 11

    SEER 19 18 19.0 19 19.0 17.0

    Rated Current (A) 8.1 3.1 8.9 4.3 7.4 9.6

    HSPF 10.0 9.5 9.5 9.5 10.0 9.5

    Cooling (°F )

    Heating (°F )

    CIRCUIT BREAKER SIZE (A) 20.0 15.0 20.0 15.0 20.0 25.0MOISTURE REMOVAL Liter/Hr 1.0 1.0 1.2 1.2 2.0 2.4

    30 30 29.6 29.6 44.1 62.8R410A (oz)

    Additional Refrigerant (oz/Ft) 0.161 0.161 0.161 0.161 0.161 0.32

    Liquid (in) 1/4" 1/4" 1/4" 1/4" 1/4" 3/8"

    Suction (in) 3/8" 3/8" 1/2" 1/2" 1/2" 5/8"

    Pre-Charged Length (Ft) 25 25 25 25 25 25

    Maximum Length (Ft) 82 82 82 82 98 98

    Maximum Height (Ft) 33 33 33 33 66 66

    AIR FLOW CFM 185 ~ 325 185 ~ 325 215 ~ 355 215 ~ 355 265 ~ 475 450 ~ 725SOUND LEVEL dB(A) 25 ~ 38 25 ~ 38 28 ~ 38 28 ~ 38 30 ~ 42 34 ~ 48

    Remote Control

    Auto Restart

    Protection

    DIMENSIONS Unit W x H x D (in) 28 ½ x 11 ½ x 7 ¼ 28 ½ x 11 ½ x 7 ¼ 31 ½ x 11 ¾ x 7 ½ 31 ½ x 11 ¾ x 7 ½ 38 x 12 ½ x 8 ½ 42 ½ x 13 ¼ x 9WEIGHT Net / Gross (LBs.) 17 17 19 19 24 30

    RLA 6.0 6.0 6.0 6.0 7.5 9.5

    LRA - - - - - -

    SOUND LEVEL dB(A) 53 53 54 54 56 58DIMENSIONS Unit W x H x D (in) 30 ¼ x 21 ¾ x 11 ¾ 30 ¼ x 21 ¾ x 11 ¾ 31 ½ x 21 ¾ x 13 ¼ 31 ½ x 21 ¾ x 13 ¼ 31 ½ x 21 ¾ x 13 ¼ 33 ¼ x 27 ½ x 14 ¼WEIGHT Net / Gross (LBs.) 67 67 70 67 80 105

    LCD WIRELES REMOTE CONTROL or WIFI

    (optional) YESTIME DELAY

    5 °F ~ 86 °FOPER. AMBIENT TEMP.

    REFRIGERANT

    INDO

    OR U

    NIT

    CONTROL

    SYST

    EM

    HEATING

    COOLING

    REFRIGERANT CONNECTIONS

    OUTD

    OOR

    UNIT

    COMPRESSOR

    5 °F~122°F