heat recovery ventilators for residential use€¦ · heat recovery ventilators for residential use...
TRANSCRIPT
OA
RA
SA EA
Operation in Winter Operation in Summer
Stale warm air(indoor return air)
Fresh warm air(indoor supply air)
Fresh cold air(outdoor air)
Stale cold air(exhaust)
Stale cool air(indoor return air)
Fresh cool air(indoor supply air)
Fresh hot air(outdoor air)
Stale hot air(exhaust)
20°C
16°C
0°C
4°C
21°C
23.8°C
35°C
32.2°C
HEAT RECOVERY VENTILATORSFOR RESIDENTIAL USE
Wall switch typeVL-100EU5-EMODEL
Equipped with soundinsulation for even quieter operation.
Easy installationthrough boring of2 installation holes.
Simple Installation
Designed to match any interior decor.
Stylish Design
Reduced heat losscontributes to lower airconditioning costs.
Energy Saving
Quiet Operation
Simultaneous airsupply/exhaust functionensures efficient ventilation.
Fresh Air
Total-Heat-Exchange Concept
•Heat-exchange Temp. equationIndoor supply-airtemperature(°C)
Calculation example : 16°C = (20°C - 0°C) x 80% + 0°C (Low fan speed)
Indoortemperature(°C)
Outdoortemperature(°C)
Outdoortemperature(°C)
Temp exchangeefficiency(%)= { }- +x
•Heat-exchange Temp. equationIndoor supply-airtemperature(°C)
Calculation example : 23.8°C = 35°C - (35°C - 21°C) x80% (Low fan speed)
Outdoortemperature(°C)
Indoortemperature(°C)
Outdoortemperature(°C)
Temp exchangeefficiency(%)= }-- { x
Y13-002(MEE) Apr.2013HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
www.MitsubishiElectric.com
(unit: mm)
(unit: mm)
ø75
ø70
60
2020
ø79
M75
NEON LAMP
M
Lo
Hi
COM
FUSE 1.0A
226
12
FRONT PANEL (OPEN POSITION)
FRONT PANEL LOUVER (HORIZONTAL POSITION)
FRONT PANEL LOUVER (VERTICAL POSITION)
FRONT PANEL (CLOSED POSITION)
EDGE OF MAIN UNIT 420
REQUIRE TO BE SECUREDREQUIRE TO BE SECURED
ABLE)(ADJUST
(ADJ
USTA
BLE)
AIR INTAKE HOLEø85 to ø90 WALL HOLE
40
108
119
95
2515
95.5
PI
TCH
20X1
0=20
0
265
13.5
238.
5
183m
infro
m n
eare
stob
stru
ctio
n23
3min
75 87
267.5
554
292
75(ADJUST
ABLE)
MOUNTING HOLES36×ø6
530
360min from nearest obstruction
200(MIN)350(MAX)
360min
620
AIR EXHAUST HOLEø85 to ø90 WALL HOLE
OU
TER
DIA
OU
TER
DIA
ø75×
2
ø79×
2
SHUTTER KNOB
WALL THICKNESS
SHUTTER KNOB
FRESH AIR SUPPLY 90 140
62054
200
5°
ø150
106
50 to 550
22 17
VL-100EU5-E
9725
POWER CORD HOLE
(CLOSED POSITION) (OPEN POSITION)
INDOOR AIR EXHAUST
(unit: mm) (unit: mm)
109
313 15
98
300 15
Out
er d
iam
eter
ø75
Inne
r dia
met
er ø
70
280
(unit: mm)
VL-100EU5-E
MOUNTING PLATE
VL-100EU5-E(White)
Optional parts
•Total length when connected to the pipe extension coupling is 300mm. •Screw-in method
•Upgraded high-performance filter. •Standard grade replacement filter.
Wiring Diagram
Dimensions
Specifications
Extension PipeP-100P-E
Extension Pipe CouplingP-100PJ-E
High performance filterP-100HF5-E
Replacement filterP-100F5-E
Fanspeed
Supplyvoltage
(V)
220
230
240
220
Power linefrequency
(Hz)
50
50
50
60
Temp.exchangeefficiency
(%)
Powerconsumption
(W)
Noise(dB)
Air volume (m3/h)
Weight(kg)
7380738072797380
HILOHILOHILOHILO
3013311534173417
36.524372538273825
10055105601066110357
7.5
•Simple installation through boring of 2 installation holes.•Low-noise(Less than 30dB at low fan speed).•1-motor 2-fan system.•Air-volume:low/high fan speeds.
•Air-supply/exhaust pipes and a plastic weather cover are included.•Equipped with an outdoor-air shutter.•Wall switch