OA RA SA EA Operation in Winter Operation in Summer Stale warm air (indoor return air) Fresh warm air (indoor supply air) Fresh cold air (outdoor air) Stale cold air (exhaust) Stale cool air (indoor return air) Fresh cool air (indoor supply air) Fresh hot air (outdoor air) Stale hot air (exhaust) 20°C 16°C 0°C 4°C 21°C 23.8°C 35°C 32.2°C HEAT RECOVERY VENTILATORS FOR RESIDENTIAL USE Wall switch type VL - 100EU 5 - E MODEL Equipped with sound insulation for even quieter operation. Easy installation through boring of 2 installation holes. Simple Installation Designed to match any interior decor. Stylish Design Reduced heat loss contributes to lower air conditioning costs. Energy Saving Quiet Operation Simultaneous air supply/exhaust function ensures efficient ventilation. Fresh Air Total-Heat-Exchange Concept •Heat-exchange Temp. equation Indoor supply-air temperature(°C) Calculation example : 16°C = (20°C - 0°C) x 80% + 0°C (Low fan speed) Indoor temperature(°C) Outdoor temperature(°C) Outdoor temperature(°C) Temp exchange efficiency(%) = { } - + x •Heat-exchange Temp. equation Indoor supply-air temperature(°C) Calculation example : 23.8°C = 35°C - (35°C - 21°C) x80% (Low fan speed) Outdoor temperature(°C) Indoor temperature(°C) Outdoor temperature(°C) Temp exchange efficiency(%) = } - - { x

Upload: others

Post on 14-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HEAT RECOVERY VENTILATORS FOR RESIDENTIAL USE€¦ · HEAT RECOVERY VENTILATORS FOR RESIDENTIAL USE Wall switch type VL-100EU5-E MODEL Equipped with sound insulation for even quieter

OA

RA

SA EA

Operation in Winter Operation in Summer

Stale warm air(indoor return air)

Fresh warm air(indoor supply air)

Fresh cold air(outdoor air)

Stale cold air(exhaust)

Stale cool air(indoor return air)

Fresh cool air(indoor supply air)

Fresh hot air(outdoor air)

Stale hot air(exhaust)

20°C

16°C

0°C

4°C

21°C

23.8°C

35°C

32.2°C

HEAT RECOVERY VENTILATORSFOR RESIDENTIAL USE

Wall switch typeVL-100EU5-EMODEL

Equipped with soundinsulation for even quieter operation.

Easy installationthrough boring of2 installation holes.

Simple Installation

Designed to match any interior decor.

Stylish Design

Reduced heat losscontributes to lower airconditioning costs.

Energy Saving

Quiet Operation

Simultaneous airsupply/exhaust functionensures efficient ventilation.

Fresh Air

Total-Heat-Exchange Concept

•Heat-exchange Temp. equationIndoor supply-airtemperature(°C)

Calculation example : 16°C = (20°C - 0°C) x 80% + 0°C (Low fan speed)

Indoortemperature(°C)

Outdoortemperature(°C)

Outdoortemperature(°C)

Temp exchangeefficiency(%)= { }- +x

•Heat-exchange Temp. equationIndoor supply-airtemperature(°C)

Calculation example : 23.8°C = 35°C - (35°C - 21°C) x80% (Low fan speed)

Outdoortemperature(°C)

Indoortemperature(°C)

Outdoortemperature(°C)

Temp exchangeefficiency(%)= }-- { x

Page 2: HEAT RECOVERY VENTILATORS FOR RESIDENTIAL USE€¦ · HEAT RECOVERY VENTILATORS FOR RESIDENTIAL USE Wall switch type VL-100EU5-E MODEL Equipped with sound insulation for even quieter

Y13-002(MEE) Apr.2013HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

www.MitsubishiElectric.com

(unit: mm)

(unit: mm)

ø75

ø70

60

2020

ø79

M75

NEON LAMP

M

Lo

Hi

COM

FUSE 1.0A

226

12

FRONT PANEL (OPEN POSITION)

FRONT PANEL LOUVER (HORIZONTAL POSITION)

FRONT PANEL LOUVER (VERTICAL POSITION)

FRONT PANEL (CLOSED POSITION)

EDGE OF MAIN UNIT 420

REQUIRE TO BE SECUREDREQUIRE TO BE SECURED

ABLE)(ADJUST

(ADJ

USTA

BLE)

AIR INTAKE HOLEø85 to ø90 WALL HOLE

40

108

119

95

2515

95.5

PI

TCH

20X1

0=20

0

265

13.5

238.

5

183m

infro

m n

eare

stob

stru

ctio

n23

3min

75 87

267.5

554

292

75(ADJUST

ABLE)

MOUNTING HOLES36×ø6

530

360min from nearest obstruction

200(MIN)350(MAX)

360min

620

AIR EXHAUST HOLEø85 to ø90 WALL HOLE

OU

TER

DIA

OU

TER

DIA

ø75×

2

ø79×

2

SHUTTER KNOB

WALL THICKNESS

SHUTTER KNOB

FRESH AIR SUPPLY 90 140

62054

200

ø150

106

50 to 550

22 17

VL-100EU5-E

9725

POWER CORD HOLE

(CLOSED POSITION) (OPEN POSITION)

INDOOR AIR EXHAUST

(unit: mm) (unit: mm)

109

313 15

98

300 15

Out

er d

iam

eter

ø75

Inne

r dia

met

er ø

70

280

(unit: mm)

VL-100EU5-E

MOUNTING PLATE

VL-100EU5-E(White)

Optional parts

•Total length when connected to the pipe extension coupling is 300mm. •Screw-in method

•Upgraded high-performance filter. •Standard grade replacement filter.

Wiring Diagram

Dimensions

Specifications

Extension PipeP-100P-E

Extension Pipe CouplingP-100PJ-E

High performance filterP-100HF5-E

Replacement filterP-100F5-E

Fanspeed

Supplyvoltage

(V)

220

230

240

220

Power linefrequency

(Hz)

50

50

50

60

Temp.exchangeefficiency

(%)

Powerconsumption

(W)

Noise(dB)

Air volume (m3/h)

Weight(kg)

7380738072797380

HILOHILOHILOHILO

3013311534173417

36.524372538273825

10055105601066110357

7.5

•Simple installation through boring of 2 installation holes.•Low-noise(Less than 30dB at low fan speed).•1-motor 2-fan system.•Air-volume:low/high fan speeds.

•Air-supply/exhaust pipes and a plastic weather cover are included.•Equipped with an outdoor-air shutter.•Wall switch