Heat Transfer in Radiators
Jignesh Gandhi
![Page 2: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/2.jpg)
Heat transfer in Radiators
n Why Cool Engines?n Engine Cooling Modelsn Engine Cooling Requirementsn Heat Rejection Curvesn How cooling Levels are reported?n Why add Ethylene Glycol?n Radiator Performance Curves
![Page 3: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/3.jpg)
Why Cool Engines?
n To analyse energy transfer in radiators, we must ask first “Why should we cool Engines?”
n Understand this by simple model on next slide.
n Based on laws of Thermodynamics.n First Law – Energy can neither be created
nor destroyed but can only change from one form to another.
n Entropy of an isolated system can never decrease.
![Page 4: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/4.jpg)
Energy Balancen Input Energy of fuel converted to
output mechanical rotational energy. But with only max 33% efficiency.
n Out of 100 %1/3 energy is mechanical energy.1/3 energy is lost to exhaust gases.1/3 energy converted to waste
heat.
![Page 5: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/5.jpg)
![Page 6: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/6.jpg)
System Componentsn Radiator, Water Pump, Fan, Thermostat
all form a cooling system.n Each component has design
characteristics and limits and hence Radiator design is a collaborative effort of all these subsystems.
n We want to further extract energy from exhaust gases and hence the business of CAC.
n We also want to cool the oil and hence the business of oil cooler.
![Page 7: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/7.jpg)
Engine Cooling Requirements
![Page 8: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/8.jpg)
![Page 9: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/9.jpg)
Typical Heat Rejection curves
n Curves developed by the manufacturers.n Plotted against engine speed as shown.n High Power Condition also called rated
power. Generally this is the maximum power developed by engine at given conditions.
n High torque is also a critical condition. n Radiator which meets high power
condition may or may not meet high torque requirements of the engine.
![Page 10: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/10.jpg)
Heat Balance n In a system, heat of engine is brought to
radiator by the coolant. This is transferred to tubes and through fins to the cooling air.
n Hence in simplistic terms, Heat given by water = M Cp (Tw in – Tw out)Heat Taken by air = U * A * LMTD
M- Mass of water flowing in kgCp – Specific heat at Const. Pr Kcal/kg/0CTwin – Temp of water at inlet to radiatorTwout- Temp of water at outlet to radiatorU – Overall heat transfer coefficient KCal/min/m2- 0CA – Core area (Heat transfer area)LMTD – Log mean temp Difference.between heat
transfer fluids. 0C
![Page 11: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/11.jpg)
![Page 12: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/12.jpg)
![Page 13: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/13.jpg)
Coolant Flow Datan As flow rate changes, the pressure
drop across the tubes in waterside will also changes.
n Hence for accurate design full data on pump characteristics is needed.
n In reality, we only get data about flow rate at max power condition. This is a big problem.
![Page 14: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/14.jpg)
Fan Curvesn How much air fan will deliver will change
based on fan characteristics.n Data generated by fan manufacturers.n Data different for Truck radiators and car
radiators.n Truck fans are engine driven and hence
variable speed.n Car fans are generally electrical.n Constraints in actual design to airflow due
to front hood, other parts etc also very important.
![Page 15: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/15.jpg)
![Page 16: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/16.jpg)
Coolantn Mixture of Ethylene Glycol and Water.n 50% most common.n Increases boiling point of water from
1000Cto 120 0C when used with 7 PSI pressure
cap.Also gives freezing protection to –37 0C .This allows us to design and operate
radiators over a larger temperature range.
![Page 17: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/17.jpg)
![Page 18: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/18.jpg)
Radiator Performance Curves
n These curves are plotted for the given radiator for different air flow ratings and related heat rejection characteristics.
n Also plotted are the air pressure drop curves for the same configuration.
n For increasing the heat transfer, we use the louvered fins or other fins which generate turbulence to improve the overall heat transfer coefficient.
What is the louver angle, how many fins per inch, how many tubes, how many rows, depth of core these are the issues which have to be decided in design to arrive at the configuration which achieves heat performance.
![Page 19: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/19.jpg)
![Page 20: Heat Transfer in Radiators](https://reader031.vdocument.in/reader031/viewer/2022020105/5527434e4a795991118b4625/html5/thumbnails/20.jpg)
Conclusion
n Radiator heat performance design is dependant on many input conditions.
n Some are specified by the customer and some are assumed by the designer.
n Heat transfer in louvered fins is a complex subject on which lot of research is in progress.
n Many times designer works with insufficient data and hence design fails in some condition.
n Design assumes 100% process capability. But if there are problems in process, good design will also fail.
n Lot of experimentation, verification and validation is mandatory requirement.