Page 1: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

Module-VAR-Variable-Speed-Heat-Pump-060118

Heating, Cooling and Indoor Air Quality Systems

www.hi-velocity.com

Installation and Operation

ESPVariable Speed Heat Pump

3 Ton ESP-36

5 Ton ESP-60

Page 2: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

2

www.hi-velocity.com

© 1995-2018 Energy Saving Products Ltd.

The ESP Inverter Series Variable Speed outdoor units are ideally suited for medium size homes. When used with the HE-Z series indoor unit, the system modulates refrigerant flow and indoor air flow to precisely match output capacity to load. The ability to match output capacity to load results in superior energy performance not just at the Minimum Energy Performance Standards (MEPS) condition but right through the operating envelope.

Inverter technology has not been well suited to concealed multizone ducted applications due to its inability to reduce capacity below 40% (over 80% of operating profile). Historically systems have overcome this problem by running the indoor fan at high flow rates and dumping excess air into part of the home. This strategy wastes energy, sacrifices comfort and often results in the coil temperature being higher than the dew point of the air, creating a muggy feeling within the home. The ESP System maintains a constant air off condition and modulates airflow, and by doing so continues to remove moisture and runs extremely quiet at night.

• Dual Inverter models utilize 180 degree full wave DC Inverter for refrigerant flow rate modulation and electronically commutated DC for Indoor air flow rate modulation.

Air Inlet

More than 12” (30 cm)

(Wall or Obstacle)

More than 12” (30 cm)

Air Inlet

Air Outlet

Maintain Channel

More than 24” (60 cm)

More than 80” (200 cm)

More than 24” (60 cm)

24” (600 mm) is necessary between 2 outdoor units

24” (60 cm)

ESP Variable Speed Heat Pump

Clearances

Module VAR Variable Speed Heat Pump Installation & Specs (2/8)

-2-

• All inverter models are single phase

• Inverter models are horizontal discharge configuration.

Page 3: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

3

www.hi-velocity.com

© 1995-2018 Energy Saving Products Ltd.

Model ESP-36 A B C D E F G38” (965 mm) 32” (813 mm) 16.25” (413 mm) 24.5” (624 mm) 13.4” (340 mm) 14.4” (366 mm) 15.6” (396 mm)

ESP Variable Speed Heat Pump Specifications - Dimensions

ESP-36

-3-

Module VAR Variable Speed Heat Pump Installation & Specs (3/8)

B

A

D

C E F G

Page 4: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

4

www.hi-velocity.com

© 1995-2018 Energy Saving Products Ltd.

Model ESP-60 A B C D E F G38” (965 mm) 53” (1346 mm) 16.25” (413 mm) 24.9” (633.5 mm) 14.6” (370 mm) 15.9” (404 mm) 17.6” (448mm)

ESP-60

-4-

Module VAR Variable Speed Heat Pump Installation & Specs (4/8)

BC

A

DE F G

ESP Variable Speed Heat Pump Specifications - Dimensions

Page 5: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

5

www.hi-velocity.com

© 1995-2018 Energy Saving Products Ltd.

• The Electronic Expansion Valve is internal to the ESP Variable Speed Heat Pump, therefore a TXV at the evaporator (indoor unit) is not needed.

Refrigeration Circuit

• Refrigeration grade copper tubing is the only tubing to be used. Fittings used for bends, elbow, ‘P’ trap, ‘Y’ piece, etc., must be of the wrought copper type and clean from dust, burrs, oil, etc. It is recommended that the tube is cut with a tube cutter and the entire ID is made the correct size with an expanding device after cutting. All joints in the piping must be clean and free from dust, burrs, oil, etc.

• All joints must be silver soldered with at least 10% silver content.

Model Liquid Line Suction Line Maximum Length Maximum Lift

ESP-36 3/8” (9.5 mm) 5/8” (15.9 mm) 213.25’ (65 m) 98.4’ (30 m)

ESP-60 3/8” (9.5 mm) 3/4” (19 mm) 213.25’ (65 m) 98.4’ (30 m)

Minimum pipe sizes, maximum length and maximum lift

Additional Refrigerant Requirement

Model Liquid Line Suction Line Factory Charge (kg)ADD REFRIGERANT

>49ft (oz/ft)

ESP-36 3/8” (9.5 mm) 5/8” (15.9 mm) 6.7 lbs (3.05 kg) 1 oz/ 3.3 ft

ESP-60 3/8” (9.5 mm) 3/4” (19 mm) 13 lbs (5.9 kg) 1 oz/ 3.3 ft

Minimum pipe sizes (up to 98’), factory charge and additional refrigerant required.

-5-

Module VAR Variable Speed Heat Pump Installation & Specs (5/8)

• Pipe insulation must be used on both liquid and suction lines.

• Maximum pipe length is 213 ft (65 m). Lines must be sized correctly to ensure that pressure drops within the system are minimized. HVAC mechanics should refer to the pipe sizing table below prior to installation.

• The ESP comes with a factory charge. Additional charge will only be needed on line sets longer than 49 ft.

Interface Panel• The interface panel is critical for indoor and outdoor unit communication.• Field wiring shown on the wiring page is needed between the indoor unit and the interface panel, and between the

interface panel and the outdoor unit using shielded cable.• The interface panel and the outdoor unit both require 240v supply power.• 2 temperature sensors are supplied with the interface panel, connected to the large circuit board. These temperature

sensors will need to be installed for the unit to operate properly.

Suction Line and Mid Coil Temperature Sensor• Remove the front access panel on the evaporator coil to gain access to the suction and mid coil temperature ports. • The temperature ports are just a short piece of open ended copper tube.• The suction port is located on the suction header. This is where the suction temperature sensor should be located and

secured.• The mid coil port is located on one of the “U-bends” in the middle of the coil. This is where the mid coil temperature sensor

should be located and secured. • Both of these temperature sensors/ports should be insulated with cork tape to ensure a true temperature reading of the

tube and not of the ambient temperature.

Page 6: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

6

www.hi-velocity.com

© 1995-2018 Energy Saving Products Ltd.

Variable Speed Heat Pump Wiring

-6-

Module VAR Variable Speed Heat Pump Installation & Specs (6/8)

OUTDOOR UNIT INVERTER HEATPUMP

L/L1 N/L2 G

208-240V / 50-60HZ

May 2018

G

W1

Y2

Y1

C

R

W2

A3

A2

A1L N

W1

W2

C

R

Y2

Y1

D

O/B

G

FZW1Y2Y1 FZW2CR

INDOOR UNIT / PSB or HEB Circuit Board

THERMOSTATP

Pump activates with2nd stage call for heat

W1 - 1st Stage Heat(Inverter)

W2 - 2nd Stage Heat(Hydronic)

24V

IN

PU

TExternal Relay

2 (W1)

1 (Y2)

3 (Not used)

4 (Not used)

C C (24v)

R (24v)

24V OUTPUT

1 1 2 2 3 3

(No

t Used

)

S2

S1

(No

Sen

sor)

(Su

ction

Lin

e S

enso

r)

(Mid

Co

ilS

enso

r)

S2S1

L1

L2 GINTERFACE PANEL

*Temperature sensors can be extended, use same gauge or larger.

Page 7: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

7

www.hi-velocity.com

© 1995-2018 Energy Saving Products Ltd.

Outdoor Unit Specifications

-7-

Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8)

System Model

Model Number ESP-36 ESP-60

Outdoor Unit Tonnage 3 Ton (10.5 kW) 5 Ton (17 kW)

Part Number 40180400003 40180400005

Capacity Data

Nominal Cooling Capacity 1) 2) 35,500 BTU (10.4 kW) 57,300 BTU (16.8 kW)

Operational Range (Cooling) 6,200-40,900 BTU (1.8 - 12 kW) 6,200-64,800 BTU (1.8 - 19 kW)

Nominal Heating Capacity 1) 2) 38,200 BTU (11.2 kW) 60,400 BTU (17.7 kW)

Operational Range (Heating) 6,200-47,400 BTU (1.8 - 14 kW) 6,200-75,000 BTU (1.8 - 22 kW)

Highest Variable Airflow 1,800 CFM (850 L/s) 2,200 CFM (1,040 L/s)

Lowest Variable Airflow 400 CFM (190 L/s) 400 CFM (200 L/s)

Electrical Data

Power Supply 240 Volts - 1 Phase - 50/60 Hz

Nom. Full Load Amps 22 30

Min. Circuit Size (Amps) 25 32

Electrical Input Cooling (kW) 1) 3.25 5.3

Electrical Input Heating (kW) 1) 3.15 5.2

ACOP 3.5 3.38

Sound Pressure (dB) (A) @ 1m 62 63

Soft Starter Variable Frequency

Dimensions - Outdoor Unit

Length 38” (965 mm) 38” (965 mm)

Width 16.25” (413 mm) 16.25” (413 mm)

Height 32” (813 mm) 53” (1346 mm)

Weight 155 lbs (70.3 kg) 269 lbs (122 kg)

NOTES:1) Capacities are based on A.S.3823.122) Capacity modulation is extended by variable indoor airflow. Actual percentage loading will vary depending on application.

DESIGN CONDITIONS:Cooling 35°C (95°F) DB Outdoor / 27°C (80°F) DB, 19°C (66°F) WB Air Entering Indoor UnitHeating 7°C (44°F)DB, 6°C (43°F) WB Outdoor/ 21°C (70°F) DB Air Entering Indoor UnitNominal Operating Range -10°C (14°F) WB to 50°C (122°F) DBSound pressure level is influenced by the surroundings, therefore it may vary upon location.

Page 8: Heating, Cooling and Indoor Air Quality Systems ESP...7 5-2 Outdoor Unit Specifications-7-Module VAR ESP Variable Speed Heat Pump Installation & Specs (7/8) System Model Model Number

© 1995-2016 Energy Saving Products Ltd.

Energy Saving Products Ltd, established in 1983, manufactures the Hi-Velocity SystemsTM product line for residential, commercial and multi-family markets. Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on Customer Service and provides design services and contractor support.

For all of your Heating, Cooling and Indoor Air Quality needs, the Hi-Velocity System is the right choice for you!