heating cooling dehumidifying air filtration temporary air management services: a brief introduction...

20
HEATING COOLING DEHUMIDIFYING AIR FILTRATION Temporary Air Management Services: A Brief Introduction of our Capabilities

Upload: liliana-wheeler

Post on 18-Dec-2015

217 views

Category:

Documents


2 download

TRANSCRIPT

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Temporary Air Management Services:A Brief Introduction of our Capabilities

Temporary Air Management Services:A Brief Introduction of our Capabilities

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Introduction to TEMP-AIR• Founded in 1965• Largest provider of

temporary heating & cooling equipment to the US construction industry with over 10,000 products.

• 12 locations nationwide.• Custom manufactures HVAC

for rental fleet.• Flexible rent, lease and

purchase options.• 24/7/365 service

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Basic Services Provided

• Bidding/Cost projections• Design of temporary system

– Sizing of Building– Placement of Equipment– Fuel Projections– Electrical Projections– Filter types and cost of

replacements

• Jobsite Monitoring• Moisture Removal and Control• Job site startup• Familiarization & routine

checks• Emergency Service

24hrs/7days• Delivery & Pickup

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Types of Heating Equipment• Direct Fired (Make-Up Air)

−Largest range of capacitieso80,000 to 4,500,000

million BTUs/Hro2,000 to 25,000 cfmoEnclosed FlameoLow Temperature

Discharge−Medium to large physical

size−Remote T-stats−Modulating for inside and

outside temperatures−95% 100% Efficient

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Types of Heating Equipment• Hydronic

− Propylene Glycol• Low to Mid Range

−250,000 – 1,200,000 BTU/Hr Input

• No Flame in structure−Heat Exchangers from

50,000 – 200,000 BTU/Hr

−710 cfm – 2,400 cfm• Applicable in tight

enclosures• 70%-80% Efficiency

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

• Indirect Fired– No combustion

contaminates– Contained flame– Requires venting– 70% to 80% fuel

efficient– Fuel Oil Fired

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Frost Removal

• Frost Removal−Hydronic−Mobile Ground Heater

oDiesel, natural gas, propane

oCoverage from 1,500- 12,000 sq. ft)

oVarious Applications

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Cooling Equipment

• 1-5 Ton Portable • 3-75 Ton Industrial• Chillers• Dehumidifiers• Air Handlers

COOLING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Dehumidifying Equipment

• Portable: 6-28 gallons of H2O/day

• Industrial: 28-387 gallons of H2O/day

• Desiccant• Refrigerant

DEHUMIDIFYING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

What is Air Quality?• “Healthy Air”

– Ambient or indoor air which is free from harmful contaminants and contains 19.5 to 22% oxygen (suitable for breathing)

• “Clean air”– Air of such purity that it

will not cause harm or discomfort to an individual if it is inhaled for extend periods of time

• OSHA Regulations (stds-29 CFR) Ventilation – 1926.57

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Ventilation Issues• Chemicals/Fumes

– Paints, Glues, Varnishes

– VOCs-carpeting, cabinets, furniture

• Dust/Particulates– Diesel exhaust

– Grinding/Sandingo Silica, Lead

– Weldingo Galvanized steel-CR, NIo Stainless Steel-ZN, flux

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Safety IssuesUse of Outside Air Can Help Reduce Safety Concerns

• Ventilation of Harmful Fumes– Paints, Glues, Varnishes, etc.– 3 main byproducts of combustion

oCO, CO2, H2O

• Carbon Monoxide (CO) Reduction– OSHA levels– Many sources on a job site

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Direct Fired Make-up Air• Pressurizes the structure

– Minimizes infiltration & cold spots

• Uniform heat distribution• Controlled ventilation (0.5-

1.0 AC/Hr)• Absorbs moisture,ventilates

toxic fumes and excessive moisture

• Lowers relative humidity levels and dew point

surface temperatures

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Moisture Problems• Condensation on

interior walls• Condensation freezes• Importance of

Mechanical Ventilation

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Desiccant DehumidifiersTD-5000 Desiccant

TD-2000 Desiccant TD-600

Desiccant

DEHUMIDIFYING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Heating Applications

• New construction or retrofits

• Masonry work• Drying or fireproofing• Taping, painting, and

other interior finish work

• Concrete pours• Supplemental or

emergency service• Military & disaster relief• Special events

HEATING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Dehumidifying Applications

• Concrete curing• Surface

preparation & treatment: drywall, painting, and other coatings

• Water damage restoration

DEHUMIDIFYING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

Cooling Applications• New construction or

retrofit finishing• Process application

cooling• Supplemental or

emergency service• Dehumidification• Military & disaster

relief• Special events

COOLING

HEATING COOLING DEHUMIDIFYING AIR FILTRATION

• Analysis of ventilation requirements to ensure compliance with OSHA regulations

• Analysis of heating, cooling, or dehumidifying requirements

• Analysis of moisture management and condensation precautions

• Equipment selection, sizing and placement during construction phases

• Fuel and power requirements

• Documentation

TEMP-AIR estimate will include: