heating programmer comparison guide - timeguard · 2013-11-29 · 3 helpline & technical...

5
Heating Programmer Comparison Guide

Upload: others

Post on 01-Apr-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Heating Programmer Comparison Guide - Timeguard · 2013-11-29 · 3 Helpline & Technical Service 020 8450 0515 Fax 020 8450 0635 Email helpline@ timeguard.com Website 4 Electronic

H e a t i n g P ro g r a m m e r C o m p a r i s o n G u i d e

Page 2: Heating Programmer Comparison Guide - Timeguard · 2013-11-29 · 3 Helpline & Technical Service 020 8450 0515 Fax 020 8450 0635 Email helpline@ timeguard.com Website 4 Electronic

energy saving

H e l p l i n e & T e c h n i c a l S e r v i c e 0 2 0 8 4 5 0 0 5 1 5 F a x 0 2 0 8 4 5 0 0 6 3 51 E m a i l h e l p l i n e @ t i m e g u a r d . c o m W e b s i t e w w w . t i m e g u a r d . c o m 2

R o o m T h e r m o s t a t s a n d H e a t i n g P r o g r a m m e r s

TRT030 TRT031 TRT032 TRT033 TRT034 TRT035 TRT036 TRT037 TRT038 TRT039 TRT044 TRT049

Timeguard Description Timeguard ProgramaStat

ACL-Drayton (Invensys)

Danfoss Randall Honeywell Horstmann

Sunvic (Formally Satchwell)

Potterton / Myson Salus

Siemens (Landis

& Staefa, Landis & Gyr)

Electronic room thermostat TRT030 RTS1 RTS2 with LED

RET-BRET230P RTE230

TLX5101 TLX5301 PRT1 RT200 RDD10

Wall mounting mechanical room thermostat offer TRT030 RMT230 T6360B

(cover extra)HRT2HRT3

TLX2259 TLX2356 MRT1 RT100 RAA20

Electronic frost thermostat with anti-tamper cover TRT031 RTS 3 RET230F5

(fi xed temp) TLX5101 FT100

Wall mounting mechanical frost thermostat with anti-tamper cover

offer TRT031 T4360 TLM2257 TLX2360

RAD1(fi xed temp)

Digital room thermostat with night set back TRT033 Digistat+ RT51 DT90E DRT1 TLX7501 RT300 RDH10

7 day digital programmable room thermostat with frost protection

TRT035 Digistat+3 TP5000 TP7000 CM907

CentaurStat 7DRT2AS2

TLX6501 and SIMPRO RT500

RDJ10 REV200 REV24

Wireless 7 day digital programmable room thermostat with frost protection

TRT037 Digistat+3 RF RF700SX

TP7000RF + RX1 CMT927 AS2RF TLX RFP RT500RF

RDJ10RF REV200RF REV24RF

7 day (or 5+2 day) digital 1 channel programmer for central heating

TRT034LP711

Tempus 1 Tempus 2

ST715Si GP103E7 ST9100C CentaurPlus C17

ChannelPlus H17XL 107XLSEP4002 EP5002 MEP1C

EP100 RWB7 RWB27

7 day (or 5+2 day) digital 2 channel programmer for central heating and hot water

TRT036

LP522LP722

Tempus 6 Tempus 7

CP715FP75FP715

FP715siFP975

GP102E5

ST6400C ST9400C ST799A

CentaurPlus C27 ChannelPlus H27

H27XL and H27ZXL207XLS

MEP2C MEP20 EP3002 EP6002

EP200RWB20 RWB29

RWB252

7 day (or 5+2 day) digital 3 channel programmer for central heating and hot water

TRT038 ChannelPlus H37XL ChannelPlus H37VXL 307XLS

7 day (or 5+2 day) digital 4 channel programmer for central heating and hot water

TRT039 ChannelPlus H47XL

Cylinder/Pipe thermostat TRT044 HTS3...PTS1 ATC….ATP LA641 LA6190B HCT2 SA2452 MCT1 CT100 RAM1

Wiring centre box TRT049 LWC1 42005748-001 SWC2202 MWB16 TC100 JB1

Quick Comparison Chart10 Great Reasons for Choosing ProgramastatThis ‘Quick Comparison Chart’ provides a ‘nearest to’ comparison to ProgramaStat. Competitors products listed may not have the same features, wiring or time periods. For full details see pages 3 to 6.Please compare the manufacturers technical data to ensure suitability. Whilst every care has been made compiling this chart Timeguard accept no responsibility for errors or omissions.

Whatever the central heating application you need to control, Timeguard can provide the answer with the new Programastat range.

When replacing a central heating programmer don’t just fi t what was there before, upgrade to Programastat.

This easy to use guide shows you which Programastat heating controller is a perfect match. Often you can simply plug in without needing to rewire.

All you have to do is locate the existing programmer in the left hand column, then simply follow the line to the far right to fi nd the recommended Programastat replacement.

Product features have been designed to cover the needs of the installer and user with simplicity in mind, all backed up by Timeguard’s three year product guarantee.

Latest benefi ts implementing the latest technology.

Complete range is all electronic.

Latest PID control.

Easy to use & programme.

Optimum Start thermostats.

Modern design family range.

Automatic summer/winter changeover.

Unique ‘Blueline’ temperature scale indicator.

1 2

3

5

67

8 9

10

4

Large blue screen displays with backlighting.

1, 2, 3 & 4 Channel versions available.

R o o m C o n t r o l R o o m C o n t r o l

Page 3: Heating Programmer Comparison Guide - Timeguard · 2013-11-29 · 3 Helpline & Technical Service 020 8450 0515 Fax 020 8450 0635 Email helpline@ timeguard.com Website 4 Electronic

H e l p l i n e & T e c h n i c a l S e r v i c e 0 2 0 8 4 5 0 0 5 1 5 F a x 0 2 0 8 4 5 0 0 6 3 53 E m a i l h e l p l i n e @ t i m e g u a r d . c o m W e b s i t e w w w . t i m e g u a r d . c o m 4

Electronic Heating Programmer Replacement ChartRecommended Replacement

Timeguard recommend replacing a 24hour or 5-2 day programmer with the 7day/5-2 day electronic programmer listed below, as it may be used in the same way. If required please call our Helpline for assistance on 020 8450 0515.

Use ProgramaStat as a general replacement for all your applications. Please check the technical details in the brochure or download the instruction sheets from our website www.timeguard.comThe information contained in this comparison guide is intended for guidance only and is believed to be correct. Timeguard can accept no liability for any errors or omissions and reserve the right to make changes at any time without notice. Installation and connection should only be carried out by a suitably qualifi ed person and in accordance with the current edition of the IEE wiring regulations.

ACL-Drayton

FP • • • • • • Replace with 7 day TRT036LP111 • • • • • Replace with 7 day TRT034LP112 • • • • • • Replace with 7 day TRT036LP241 • • • • • Replace with 7 day TRT036LP522 • • • • • Replace with 7 day TRT036LP711 • • • • • Replace with 7 day TRT034LP722 • • • • • TRT036LS111 • • • • • Replace with 7 day TRT034LS112 • • • • • • Replace with 7 day TRT036LS241 • • • • • Replace with 7 day TRT036LS522 • • • • • Replace with 7 day TRT036LS711 • • • • • Replace with 7 day TRT034LS722 • • • • • TRT036MP • • • • • • Replace with 7 day TRT036Switchmaster 300 • • • • • Replace with 7 day TRT034Switchmaster 320 • • • • • • Replace with 7 day TRT036Switchmaster 350 • • • • • • Replace with 7 day TRT036Switchmaster 400 • • • • • • Replace with 7 day TRT036Switchmaster 600 • • • • • • Replace with 7 day TRT036Switchmaster 805 • • • • • • Replace with 7 day TRT036Switchmaster 900 • • • • • • Replace with 7 day TRT036Switchmaster 9000 • • • • • • Replace with 7 day TRT036Switchmaster 9001 • • • • • • Replace with 7 day TRT036Switchmaster 905 • • • • • • Replace with 7 day TRT036Switchmaster 980 • • • • • Replace with 7 day TRT034Switchmaster Sonata • • • • • TRT036TC • • • • • Replace with 7 day TRT034Tempus 1 • • • • • Replace with 7 day TRT034Tempus 2 • • • • • Replace with 7 day TRT034Tempus 3 • • • • • • Replace with 7 day TRT036Tempus 4 • • • • • • Replace with 7 day TRT036Tempus 6 • • • • • • Replace with 7 day TRT036Tempus 7 • • • • • • Replace with 7 day TRT036

Danfoss Randall

102 • • • • • • Replace with 7 day TRT036102E • • • • • • Replace with 7 day TRT036102ES • • • • • • Replace with 7 day TRT036102E7 • • • • • • Replace with 7 day TRT036103 • • • • • Replace with 7 day TRT034103E • • • • • Replace with 7 day TRT034103ES • • • • • Replace with 7 day TRT034103E7 • • • • • Replace with 7 day TRT0343001 • • • • • Replace with 7 day TRT0343002 • • • • • • Replace with 7 day TRT0363020P • • • • • Replace with 7 day TRT0363033 • • • • • • Replace with 7 day TRT036

Danfoss Randall

3060 • • • • • • Replace with 7 day TRT0364033 • • • • • • Replace with 7 day TRT036701 • • • • • • Replace with 7 day TRT036702 • • • • • • Replace with 7 day TRT036911 • • • • • Replace with 7 day TRT034917 • • • • • Replace with 7 day TRT034922 • • • • • Replace with 7 day TRT036971 • • • • • Replace with 7 day TRT034972 • • • • • TRT036CP15 • • • • • • • Replace with 7 day TRT036CP75 • • • • • • Replace with 7 day TRT036CP715 • • • • • • Replace with 7 day TRT036FP15 • • • • • Replace with 7 day TRT036FP75 • • • • • TRT036FP715 • • • • • • Replace with 7 day TRT036FP975 • • • • • Replace with 7 day TRT036MP15 • • • • • • Replace with 7 day TRT036MP75 • • • • • • Replace with 7 day TRT036SET1 • • • • • Replace with 7 day TRT034SET1E • • • • • Replace with 7 day TRT034SET2 • • • • • • Replace with 7 day TRT036SET2E • • • • • • Replace with 7 day TRT036SET3E • • • • • • Replace with 7 day TRT036SET3M • • • • • • Replace with 7 day TRT036SET4 • • • • • Replace with 7 day TRT034SET5 • • • • • • • Replace with 7 day TRT036TS15 • • • • • Replace with 7 day TRT034TS75 • • • • • Replace with 7 day TRT034TS715 • • • • • Replace with 7 day TRT034TS975 • • • • • • Replace with 7 day TRT034

Glowworm Masterminder • • • • • • Replace with 7 day TRT036

Honeywell

ST1000 • • • • • • Replace with 7 day TRT036ST1501 • • • • • Replace with 7 day TRT036ST1507 • • • • • TRT036ST6100A • • • • • Replace with 7 day TRT034ST6100C • • • • • Replace with 7 day TRT034ST6200A • • • • • • Replace with 7 day TRT036ST6300A • • • • • • Replace with 7 day TRT036ST6400C • • • • • TRT036ST6450B • • • • • Replace with 7 day TRT036ST6998 Fully Pumped • • • • • • Replace with 7 day TRT036ST6998 Gravity • • • • • • Replace with 7 day TRT036ST7000A • • • • • • Replace with 7 day TRT036ST7000B • • • • • Replace with 7 day TRT034ST7100 • • • • • Replace with 7 day TRT036ST799A • • • • • • Replace with 7 day TRT036

Horstmann

423 Amethyst 10 • • • • • • Replace with 7 day TRT036423 Amethyst 7 • • • • • • Replace with 7 day TRT036423 Diamond • • • • • • Replace with 7 day TRT036423 Emerald • • • • • Replace with 7 day TRT034423 Pearl Auto • • • • • Replace with 7 day TRT034424 Coral • • • • • • Replace with 7 day TRT036424 Diamond • • • • • • Replace with 7 day TRT036424 Emerald • • • • • Replace with 7 day TRT034424 Gem • • • • • • Replace with 7 day TRT036424 Pearl Auto • • • • • Replace with 7 day TRT034425 Coronet • • • • • Replace with 7 day TRT034425 Diadem • • • • • • Replace with 7 day TRT036

Manufacturer Model Mec

hani

cal

Elec

tron

ic

24 H

our

5/2

Dda

y

7 D

ay

Sing

le C

hann

el

Two

Chan

nel

Thre

e Ch

anne

l

Four

Cha

nnel

Sing

le C

ircu

it

Two

Circ

uit

1.5

Circ

uits

Tim

esw

itch

Min

i-Pr

ogra

mm

er

Prog

ram

mer

Com

mon

Tim

e Ba

se

Prog

ram

mab

le T

herm

osta

t

Wir

eles

s

Recommended Replacement

Timeguard

ProgramaStat TRT034 • • • • • •

ProgramaStat TRT035 • • • • •

ProgramaStat TRT036 • • • • • •

ProgramaStat TRT037 • • • • • • •

ProgramaStat TRT038 • • • • •

ProgramaStat TRT039 • • • • •

Manufacturer Model Mec

hani

cal

Elec

tron

ic

24 H

our

5/2

Day

7 D

ay

Sing

le C

hann

el

Two

Chan

nel

Thre

e Ch

anne

l

Four

Cha

nnel

Sing

le C

ircu

it

Two

Circ

uit

1.5

Circ

uits

Tim

esw

itch

Min

i-Pr

ogra

mm

er

Prog

ram

mer

Com

mon

Tim

e Ba

se

Prog

ram

mab

le T

herm

osta

t

Wir

eles

s

Recommended Replacement

Timeguard

ProgramaStat TRT034 • • • • • •

ProgramaStat TRT035 • • • • •

ProgramaStat TRT036 • • • • • •

ProgramaStat TRT037 • • • • • • •

ProgramaStat TRT038 • • • • •

ProgramaStat TRT039 • • • • •

H e a t i n g P r o g r a m m e r C o m p a r i s o n G u i d e

Continued on next page.

R o o m C o n t r o l R o o m C o n t r o l

Page 4: Heating Programmer Comparison Guide - Timeguard · 2013-11-29 · 3 Helpline & Technical Service 020 8450 0515 Fax 020 8450 0635 Email helpline@ timeguard.com Website 4 Electronic

H e l p l i n e & T e c h n i c a l S e r v i c e 0 2 0 8 4 5 0 0 5 1 5 F a x 0 2 0 8 4 5 0 0 6 3 55 E m a i l h e l p l i n e @ t i m e g u a r d . c o m W e b s i t e w w w . t i m e g u a r d . c o m 6

TRT030 TRT031 TRT032 TRT033 TRT034 TRT035 TRT036 TRT037 TRT038 TRT039 TRT044 TRT049

Horstmann

425 Tiara • • • • • • Replace with 7 day TRT036517 • • • • • Replace with 7 day TRT034525 • • • • • Replace with 7 day TRT036527 • • • • • TRT036Centaur SC1 • • • • • Replace with 7 day TRT034Centaur SC7 • • • • • Replace with 7 day TRT034Centaur TC1 • • • • • • Replace with 7 day TRT036Centaur TC7 • • • • • • Replace with 7 day TRT036CentaurPlus C11 • • • • • Replace with 7 day TRT034CentaurPlus C17 • • • • • TRT034CentaurPlus C21 • • • • • Replace with 7 day TRT036CentaurPlus C27 • • • • • TRT036ChannelPlus H11XL • • • • • Replace with 7 day TRT034ChannelPlus H17XL • • • • • TRT034ChannelPlus H21XL • • • • • Replace with 7 day TRT036ChannelPlus H27ZXL • • • • • TRT036ChannelPlus H27XL • • • • • TRT036ChannelPlus H37XL • • • • TRT038ChannelPlus H37VXL • • • • TRT038ChannelPlus H47XL • • • • TRT039

SiemensLandis & GyrLandis & Staefa

RWB100 • • • • • Replace with 7 day TRT034RWB102 • • • • • • Replace with 7 day TRT036RWB152 • • • • • Replace with 7 day TRT034RWB170 • • • • • Replace with 7 day TRT034RWB2 • • • • • • Replace with 7 day TRT036RWB20 • • • • • • Replace with 7 day TRT036RWB200 • • • • • • Replace with 7 day TRT036RWB252 • • • • • Replace with 7 day TRT036RWB270 • • • • • TRT036RWB3 • • • • • Replace with 7 day TRT034RWB30 • • • • • • Replace with 7 day TRT034RWB40 • • • • • Replace with 7 day TRT034RWB50 • • • • • Replace with 7 day TRT034RWB7 • • • • • • • Replace with 7 day TRT034RWB9 • • • • • • • Replace with 7 day TRT036

MysonMicrotimer One • • • • • Replace with 7 day TRT036Microtimer Seven • • • • Replace with 7 day TRT036

Pegler Sunvic

MP2 • • • • • • Replace with 7 day TRT036Select 107 • • • • • • Replace with 7 day TRT034Select 207 • • • • • • Replace with 7 day TRT036SP100 • • • • • TRT036SP2 • • • • • • Replace with 7 day TRT036SP20 • • • • • Replace with 7 day TRT034SP25 • • • • • • Replace with 7 day TRT036SP30 • • • • • • Replace with 7 day TRT036SP35 • • • • • Replace with 7 day TRT034SP50 • • • • • C Replace with 7 day TRT036

Potterton

EP2000 • • • • • • Replace with 7 day TRT036EP2001 • • • • • • Replace with 7 day TRT036EP2002 • • • • • • Replace with 7 day TRT036EP3000 • • • • • • Replace with 7 day TRT036EP3001 • • • • • • Replace with 7 day TRT036EP3002 • • • • • • Replace with 7 day TRT036EP4000 • • • • • Replace with 7 day TRT034EP4001 • • • • • Replace with 7 day TRT034

Potterton

EP4002 • • • • • Replace with 7 day TRT034EP5002 • • • • • Replace with 7 day TRT034EP6000 • • • • • TRT036EP6002 • • • • • TRT036Mini Minder • • • • • • Replace with 7 day TRT036Mini Minder E • • • • • • Replace with 7 day TRT036Mini Minder ES • • • • • Replace with 7 day TRT034

Salus

EP100 • • • • • • TRT034EP101 – voltage free • • • • • • Possibly TRT034 but not voltage freeEP200 • • • • • • TRT036RT500RF – voltage free • • • • • • Possibly TRT035 but not voltage freeRT500 – voltage free • • • • • Possibly TRT037 but not voltage free

Sangamo

409 form 8 • • • • • Replace with 7 day TRT034410 form 8 • • • • • Replace with 7 day TRT034M5 • • • • • • Replace with 7 day TRT036M6 • • • • • Replace with 7 day TRT034

Smiths Industries

Centroller 100 • • • • • • Replace with 7 day TRT036Centroller 1000 • • • • • • Replace with 7 day TRT036Centroller 30 • • • • • Replace with 7 day TRT034Centroller 40 • • • • • Replace with 7 day TRT034Centroller 50 • • • • • Replace with 7 day TRT034Centroller 60 • • • • • • Replace with 7 day TRT036Centroller 70 • • • • • • Replace with 7 day TRT036Centroller 90 • • • • • • Replace with 7 day TRT036Centroller MK1 • • • • • Replace with 7 day TRT034Centroller MK2 • • • • • Replace with 7 day TRT034

Towerchron

DP72 • • • • • TRT036DT71 • • • • • Replace with 7 day TRT036QE1 • • • • • Replace with 7 day TRT034QE2 • • • • • TRT036T2001 • • • • • Replace with 7 day TRT034T2001Q • • • • • Replace with 7 day TRT034T2002 • • • • • • Replace with 7 day TRT036T2002Q • • • • • • Replace with 7 day TRT036T2003 • • • • • • Replace with 7 day TRT036T2003Q • • • • • • Replace with 7 day TRT036

Venner

CHC/W2 • • • • • • Replace with 7 day TRT036Venetrol 80 • • • • • • Replace with 7 day TRT036Venetrol 80M • • • • • • Replace with 7 day TRT036Venetrol 80P • • • • • • Replace with 7 day TRT036Venetrol 80P/M • • • • • • Replace with 7 day TRT036Venner T10 • • • • • Replace with 7 day TRT034Venner T20 • • • • • • Replace with 7 day TRT036Venner T30 • • • • • • Replace with 7 day TRT036Venotime • • • • • Replace with 7 day TRT034

Important: Installation and connection should be undertaken by a suitably qualifi ed person in accordance with the IEE Wiring Regulations. Before removing any exsisting programmer note the wire colours, terminal positions and numbers in relation to the existing backplate then ensure the replacement unit is correctly terminated. Any spare wires, maybe formally connected into linking terminals, should be connected into a separate terminal block (not supplied), wires from different spare terminals should not be joined together.Whilst every care has been made compiling this chart from previously held data Timeguard can accept no reponsibility for errors or omissions.The Timeguard cat no TRT038 and TRT039 three and four channel 7 day heating programmers are designed for fully pumped systems. The Timeguard cat no TRT036 two channel 7 day heating programmer is designed for either pumped or gravity fed systems. All Timeguard digital heating programmers have AUTOMATIC summer-winter time change, ADVANCE and BOOST facility. Surface mounting over standard BS box fi xings.

Manufacturer Model Mec

hani

cal

Elec

tron

ic

24 H

our

5/2

Day

7 D

ay

Sing

le C

hann

el

Two

Chan

nel

Thre

e Ch

anne

l

Four

Cha

nnel

Sing

le C

ircu

it

Two

Circ

uit

1.5

Circ

uits

Tim

esw

itch

Min

i-Pr

ogra

mm

er

Prog

ram

mer

Com

mon

Tim

e Ba

se

Prog

ram

mab

le T

herm

osta

t

Wir

eles

s

Recommended Replacement

Timeguard

ProgramaStat TRT034 • • • • • •

ProgramaStat TRT035 • • • • •

ProgramaStat TRT036 • • • • • •

ProgramaStat TRT037 • • • • • • •

ProgramaStat TRT038 • • • • •

ProgramaStat TRT039 • • • • •

Manufacturer Model Mec

hani

cal

Elec

tron

ic

24 H

our

5/2

Day

7 D

ay

Sing

le C

hann

el

Two

Chan

nel

Thre

e Ch

anne

l

Four

Cha

nnel

Sing

le C

ircu

it

Two

Circ

uit

1.5

Circ

uits

Tim

esw

itch

Min

i-Pr

ogra

mm

er

Prog

ram

mer

Com

mon

Tim

e Ba

se

Prog

ram

mab

le T

herm

osta

t

Wir

eles

s

Recommended Replacement

Timeguard

ProgramaStat TRT034 • • • • • •

ProgramaStat TRT035 • • • • •

ProgramaStat TRT036 • • • • • •

ProgramaStat TRT037 • • • • • • •

ProgramaStat TRT038 • • • • •

ProgramaStat TRT039 • • • • •

Notes

H e a t i n g P r o g r a m m e r C o m p a r i s o n G u i d e

Electronic Heating Programmer Replacement Chart (continued)

R o o m C o n t r o l R o o m C o n t r o l

Page 5: Heating Programmer Comparison Guide - Timeguard · 2013-11-29 · 3 Helpline & Technical Service 020 8450 0515 Fax 020 8450 0635 Email helpline@ timeguard.com Website 4 Electronic

Sales Offi ce Direct Line

Tel: 020 8452 1112 Fax: 020 8450 0635 E-mail: [email protected]

Helpline & Technical Service Direct Line

Tel: 020 8450 0515 Fax: 020 8450 0635 E-mail: [email protected]

General Enquiries

Tel: 020 8450 8944 Fax: 020 8452 5143 E-mail: [email protected]: www.timeguard.com

Siemens... Landis & Gyr, Landis & Staefa

RWB2/20/40/200/252/270/XP/9 1 2 3 4 – N L

ACL-Drayton…...Invensys

MP – – 6 10 – 2 1

FP 8 11 6 10 – 2 1

2000 HW OFF

CH OFF

HW ON

CH ON – N L

112 – – 3 4 – N L

241/522/722 1 2 3 4 – N L

Tempus 314/7 1 2 3 4 – N L

Glowworm Mastermind 1 2 3 4 – N L

Honeywell ST499A – – 6 3 – N L

ST6998B/ST699C 7 4 6 3 – N L

ST6300A/ST6400C 1 2 3 4 – N L

ST7100 7 4 8 5 – N L

Horstmann 525/527 3 6 1 4 – N L

Centaur TC1/TC7 2 – 3 4 – N L

Diadem/Tiara 3 6 1 4 – N L

Gem 6 9 4 7 – 2 1

Diamond 423 – – 2 4 – N L

Potterton / Myson 411 – – 3 4 – N,1,8 L,2,9

423/424 - - 7,8 4 – 2,3 1

Mini-Minder 1 2 3 4 – *N L

EP2000/3000/2001/ 3001/6000 1 2 3 4 – N L

Danfoss Randall 102 – – 1 2 – 5 6

3020P – – 4 2 – 7,1 6

3033 5 3 4 2 – 7,1 6

3060 – – 4 2 – 7,1 6

Set2/Set5 3 6 1 4 – N L

4033 5 3 4 2 – N 1,6

701/702 4 2 3 1 – N L

922/972 1 4 3 6 – N L

Sangamo 409-1 – – 2 5 – N L

409-3 4 2 5 1 – *N,1,3 7

409-4 – – 2 5 – 3, 6 L

410-1 2 7 1 8 – *N,1,3 3,6

410-2 2 7 - 8 – 4,5 1,3,6

410-3 1 2 7 8 – 4,5 6

414 2 7 1 8 – 4,5 3

Sunvic(Satchwell)

DHP2301 8 5 6 3 – 1 2

ET1401/1451 8 5 7 4 – 1 2

SP2 1 4 3 6 – N L

SP50 1 4 2 5 – N 3

SP100 1 4 2 5 – N L

Smiths Industries Centroller 10/100 – – 3 2 – N L

Centroller 60/70/90 – – 4 5 – 1 2

Superswitch – – 4 1 – 2 3

Switchmaster 320 – – 3 1 – N,2 L

350 – – 3 1 – N,2 L

400/600 – – 3 1 – N L

800/805/900/905/ 9000/9001 4 2 3 1 – N L

Sonata Symphony 900/9000/9001 3 6 1 4 – N L

Tower DP72 1 2 3 4 – #N L

AMF Venner CHC / W2/80 – – 2 AS – $N,1,3,4 L

T20/T30 – – 2 6 – $N,2,3 L

80M/80PM 1 4 2 AS – #N,3 L

80P – – 2 AS – #N,1,3 L

Make and Reference Number HW OFF

CH OFF

HW ON

CH ON E N L

Timeguard Single Channel TRT034 – NC1 – NO1 – N L

Timeguard Two Channel TRT036 NC2 NC1 NO2 NO1 – N L

Make and Reference Number HW OFF

CH OFF

HW ON

CH ON E N L

Timeguard Single Channel TRT034 – NC1 – NO1 – N L

Timeguard Two Channel TRT036 NC2 NC1 NO2 NO1 – N L

Replacement Programmer Wiring GuideBefore removing any existing programmer it is essential to make a note of wire colours, terminal positions and numbers in relation to the existing backplate. The charts below only include programmers or timeswitches where wiring changes are necessary when fi tting our recommended replacement. Where a direct plug-in replacement is available or where terminal connections do not change the appropriate replacement is shown on the Electronic Heating Programmer Replacement Chart (pages 3 to 6).

Whilst we have tried to ensure accuracy, this chart was compiled from previously held data and may contain errors, please check carefully and ensure no links have been omitted. Timeguard can accept no responsibility for errors or omissions.

Please ensure you have used the correct data and check that all screws are tight. Installation should be carried out by a suitably qualifi ed person in accordance with the IEE Wiring Regulations.

When replacing the Siemens RWB20 a neutral connection to the backplate is required.

* Link old 4+6 in separate terminal block.

# On Venner units (AS) terminals X2 if both wired. One goes to CH ON (NO1) on TRT036 and you will have to link the remaining (AS) terminal and the wire from terminal 5 together.

$ Link wires 5+4 from the old unit in a separate terminal block together.

Important

Notes

Zerofour – January 2010