heavy duty industrial pressure sensor€¦ · throttle (attach to the adapter before use.) o-ring...
TRANSCRIPT
Heavy Duty Industrial Pressure Sensor
For Hydraulic and Pneumatic Applications
STEP FLUSH DIAPHRAGMStandard equipment
Actual size
GP-M Series
RUGGED, VERSATILE, AND HIGHLY VISIBLE
180°Back side
Easy to See Easy to Mount
Heavy Duty Digital Pressure SensorsGP-M Series
OIL, WATER, and AIR…
One sensor with the ability to solve a wide variety of applications
Easy to program
Easy to mount
Easy to monitor
Resistant to damage
Fluidtemperature range
-20 to+100°C-4 to+212°F
Vibration resistance
20G
Shock resistance
50G
2
New Standard in user-friendly operation to solve a wide range of applications
1
2
3
Easy to use
New features include the easy to clean,
clog resistant structure and a highly visible
indicator and display. In combination with
its intuitive operation, the GP-M provides the
next level of ease-of-use functionality.
Its hex-shaped design, rotatable display, and
user-friendly setup simplify the installation.
With six different models available, the
GP-M can be used for almost any pressure
application. Its standard footprint for all
models simplifies integration.
Easy to install
Easy to select
The flat surface diaphragm is easy to clean and resists clogging.
only 1size for all 6 models
330°
THE NEW STANDARD FOR VERSATILE
AND RUGGED PRESSURE SENSORS
GP-MSeries
3
Highly Visible Indicators & DisplayEasy to see operation status from any viewing direction
Overhead mounting
Rear facing
Front facing
Low level mounting
1 Easy to use
4
5
Clog resistant. No disassembly required for cleaning.STEP FLUSH DIAPHRAGM DESIGN
The GP-M features a step flush diaphragm design that prevents foreign materials from clogging the unit.
Large Display Easy to see the current operation status from any viewing direction.
Back side180°
Inverse display functionThe digitial display can be inverted 180 degrees, which allows installation in nearly any orientation.
Prevent unauthorized changesKey Lock and Password Protection settings are available to prevent unauthorized changes from being made.
Easy MaintenanceClogging inside of the sensor may lead to a delayed response or errors in detection values. The GP-M can be removed and cleaned when couplings or other connecting parts become clogged. The step flush diaphragm design simplifies debris removal.
Conventional: Bourdon tube & Mechanical type・Values are difficult to understand
・Require more space due to large size
・More potential for leaks and damage
・No outputs provided
GP-M Series・Anyone can understand the large numerical display
・Outputs can easily be seen at a glance from any direction
・Space-saving design
・Includes an adjustable range analog function.
Advantage of using digital pressure sensor
The sensor display can be rotated after mounting the sensor
330°
3 SIMPLE STEPS FOR INSTALLATION
Rotating
Mount the sensor to the coupling1
CONVENTIONAL INSTALLATION
Sensor
Union
Additional part added
* Researched by KEYENCE
1.57"
Space saving is possible because the union is unnecessary
Up to
40mm
increase in height
2 Easy to install
Fixed
Adjust the display orientation2 Attach the cable3
Installation does not require a union in order to adjust the display orientation. Therefore, the number of parts can be reduced by eliminating the need for this adapter.
Rotating head = No union required
6
GP-M001 -14.50 to +14.50 PSI (-100 to +100 kPa)
GP-M010 -14.5 to +145.0 PSI (-0.1 to +1 MPa)
GP-M025 -14.5 to +362.6 PSI (-0.1 to +2.5 MPa)
GP-M100 0 to +1450 PSI (0 to +10 MPa)
GP-M250 0 to +3626 PSI (0 to +25 MPa)
GP-M400 0 to +5802 PSI (0 to +40 MPa)
Rugged durability and environmental resistance
1 2 3Sensor Cable Adapter
NPTR
Tee Rc
G
NPN/PNP selectable
Selectable between [2 outputs] or [1 output + analog output]
Range Selection
0 PSI0 MPa
ø34.2 mm1.35"
3.41"86.7 mm
M124pin
G 43
SUSXM7
Al2O3
(Alumina)
TOUGH &HEAVY-DUTY
High chemical resistance and hardness
AluminaCeramic diaphragm:
Straight type
L-shaped type
• It is recommended to attach a throttle (KEYENCE optional accessory) when an exceptionally large pulse or surge pressure is expected.
* No freezing or condensation
3 Easy to select
Simple lineup
Various cables and adapteraccessories are available
50G
Shockresistance
-20 to+100°C*-4 to+212°F
Fluid temperature range
20G
Vibrationresistance
150g
Light weight
7
A P P L I C AT I O N S
With its wide pressure range, from -14.5 to +5802 PSI (−0.1 to +40 MPa), and ceramic (alumina) diaphragm with high oil resistance, the GP-M Series can inspect pressure in a variety of applications.
The step flush diaphragm, with its small indentation inside of the sensor, prevents liquid and bubbles from easily clogging the pipe. In addition, it is easy to remove this sensor for cleaning. Users should consider the GP-M Series for fluids that commonly result in clogging.
The GP-M Series can monitor fluids between -20 and +100°C -4 and +212°F and can therefore be used in a wide variety of applications ranging from cooling, heat retention, and sterilization. (Ensure that the environment is free from freezing or condensation.)
OIL PRESSURE
Thick fluid, fluid-containing powdersand foreign materials
Fluid between -20 and +100°C -4 and +212°F
Machine tools
Work clamp pressure
Coolant discharge pressure
Checking workpiece setting
Monitoring clogging of waste liquid containing contaminants
Fluid examples
Grease
Coating material
Adhesive
Flux
Sealant
Applications at high temperatures
Clogging of a strainer
Checking back pressure of a steam trap
Water pressure for antiseptic wash
8
SEL ECTAB LE FUNCT IONS ACCORD ING TO THE APP L ICAT ION
Initial setting of the hysteresis mode (Hno/Hnc)
2 3 4 51
FH
FL
Hysteresis
FnoFnC
Hysteresis
1rP
SP
HnoHnC
2 3
Free range analog Hold function
Window mode (Fno/Fnc)
Pressure is likely to fluctuate from factors such as pressure spikes. This mode allows for free adjustment of hysteresis in order to prevent chattering due to fluctuating pressure.
The data is output within the range of 4 to 20 mA in correspondence with the upper and lower limit values of the required pressure range. The pressure range can be adjusted as desired to maximize resolution.
This function displays the peak value and bottom value measured since the GP-M Series was turned on. Users can check the peak and bottom values easily by quickly pressing the ▲ or ▼ button while pressing the MODE button.
This mode is used to judge whether or not a measurement value is inside or outside of a specified zone.
Assume that SP-rP = Hysteresis
The mode turns ON when a measurement value rises above SP.
The mode turns ON when a measurement value rises above FL + Hysteresis.
The mode turns OFF when a measurement value rises above FH.
The mode turns ON when a measurement value falls below FH – Hysteresis.
The mode turns OFF when a measurement value falls below FL.
The mode turns OFF when a measurement value falls below rP. 2 3
Hysteresis
* The “hysteresis mode” and “window mode” can be selected for control outputs 1 and 2 respectively.
1 2
1 2
2 3
3 4
4 5
Response speed (chattering prevention)
This function ignores rapid changes due to such factors as pressure spikes by increasing the response time. The time can be adjusted from 3 to 5000 ms.
9
Specifications Model Material Connector type Cable termination Length (m ft)
Standard
OP-75721
PVC
(Vinyl chloride)
M12 4 pinsStraight
Loose wire
2 6.56'
OP-87272 5 16.40'
OP-85502 10 32.81'
OP-75722
M12 4 pinsL-shape
2 6.56'
OP-87273 5 16.40'
OP-87274 10 32.81'
OIil-resistant
OP-87636
PUR
(Polyurethane)
M12 4 pinsStraight
2 6.56'
OP-88067 5 16.40'
OP-87637 10 32.81'
OP-87640
M12 4 pinsL-shape
2 6.56'
OP-88068 5 16.40'
OP-87641 10 32.81'
Appearance Model Rated pressure range Fluid type Thread diameter
GP-M001 -14.50 to +14.50 PSI (-100 to +100 kPa)
GasLiquid
G3/4
GP-M010 -14.5 to +145.0 PSI (-0.1 to +1 MPa)
GP-M025 -14.5 to +362.6 PSI (-0.1 to +2.5 MPa)
GP-M100 0 to +1450 PSI (0 to +10 MPa)
LiquidGP-M250 0 to +3626 PSI (0 to +25 MPa)
GP-M400 0 to+5802 PSI (0 to +40 MPa)
Appearance Model Type
OP-87281 R male 1/8
OP-87282 R male 1/4
OP-87280 R male 3/8
OP-87283 G female 1/4
OP-87284 NPT male 1/8
OP-87285 NPT male 1/4
OP-87286 Rc female 1/2
Appearance Model Material
OP-87289 Polysulfone
Appearance Model Material
OP-87310 FKM
Appearance Model Material Applicable adapter
OP-87311 SUS303OP-87280/OP-87281OP-87282/OP-87284
OP-87285
OP-87312 SUS303 OP-87283
Appearance Model Material
OP-87287 FKM
Appearance Model Material
OP-87288O-ring: FKM
Backup ring: PTFE
L I N E U P
Display protection cover
O-ring (for OP-87283)
Throttle (Attach to the adapter before use.)
O-ring (for GP-M001/M010/M025)
O-ring set (for GP-M100/M250/M400)
0
Use the set in combination: O-ring (black) and the backup ring (white)
It is recommended to attach a throttle to the GP-M100/M250/M400. For the other models, use it when excessive pulses or surge pressure is expected.
Do not use unauthorized items. Refer to Page 14 "PIPING/INSTALLATION" for details.
Replacement parts (Available for the following model numbers. Sold separately.)
1 Sensor
2 Cable
3 Adapter (Select from the following adapters.)
10
Model GP-M001 GP-M010 GP-M025 GP-M100 GP-M250 GP-M400
Rated pressure -14.50 to +14.50 PSI (-100 to +100 kPa)
-14.5 to +145.0 PSI (-0.1 to +1 MPa)
-14.5 to +362.6 PSI (-0.1 to +2.5 MPa)
0 to +1450 PSI (0 to +10 MPa)
0 to +3626 PSI (0 to +25 MPa)
0 to+5802 PSI(0 to+40 MPa)
Possible display range -17.40 to +17.40 PSI (-120.0 to +120.0 kPa)
-30.5 to +161.0 PSI (-0.210 to +1.110 MPa)
-52.2 to +400.3 PSI (-0.360 to +2.760 MPa)
-145 to +1595 PSI (-1.00 to +11.00 MPa)
-363 to +3989 PSI (-2.50 to +27.50 MPa)
-580 to+6382 PSI(-4.00 to+44.00 MPa)
Zero-cut pressure value ±0.5% of F.S.
Allowable pressure 58 PSI (400 kPa) 580 PSI (4 MPa) 1450 PSI (10 MPa) 4351 PSI (30 MPa) 7252 PSI (50 MPa) 7252 PSI (50 MPa)
Burst pressure 217.5 PSI (1500 kPa) 2175 PSI (15 MPa) 5075 PSI (35 MPa) 14504 PSI (100 MPa) 14504 PSI (100 MPa) 14504 PSI (100 MPa)
Display resolution
kPa 0.1 1 1 None None None
MPa None 0.001 0.001 0.01 0.01 0.01
PSI 0.01 0.1 0.1 1 1 1
bar 0.001 0.01 0.01 0.1 0.1 0.1
kgf/cm2 0.001 0.01 0.01 0.1 0.1 0.1
Fluid type Gas or liquid that will not corrode the liquid contact part Liquid that will not corrode the liquid contact part
Type of pressure Gage pressure
Precision*1 ±1.0% of F.S. or less
Repeatability*2 ±0.3% of F.S. or less
Temperature characteristics ±0.6% of F.S./10°C 50°F
Connection port G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)
Box rotation angle Maximum 330°
Medium temperature -20 to +100°C -4°F to +212°F (no freezing/condensation)*3 *6
Power voltage 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS
Current consumption 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4
Display method 4 column, digital LED, red/Vertical inversion display possible
Operation display light Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)
Hysteresis During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)During window mode: fixed (0.5% of F.S.)
ResponseControl output Selectable from 3 to 5000 ms
Analog output As above + 2 ms (90% response)
Output 1 control output NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)Main unit residual voltage 1 V max,N.O./N.C. selectableOutput 2
replacement typeControl output
Analog output 4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5
Environmentalresistance
Ambient temperature -20 to +80°C -4°F to +176°F (no freezing/condensation)*6
Relative humidity 35 to 85% RH (no condensation)*6
Vibration IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)
Shock IEC60068-2-27 50 G (11 ms, 3 times for each of X, Y and Z axis)
Enclosure rating IP67
Materialproperties
Wetted part Pressure port: SUSXM7, Diaphragm pressure port: Al2O3(Alumina), O ring: FKM
Other parts Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole*7: PTFE, nickel-plated brass.
Applicable cable M12 connector 4 pin
Weight App. 150 g
S P E C I F I C AT I O N S
W I R I N G, O U T P U T D I A G R A MWhen selecting an NPN output
Analog output diagram
*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.*4 Consumption current including output is 0.6 A and under.*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = (38 × (E-10) + 128) Ω When 23-30V: R = 622 Ω*6 For measures to prevent condensation, refer to Page 14 "Other precautions" 7.*7 Only for the GP-M001/M010/M025
* When selecting "Out"(control output) of the function of output 2 only.
* When selecting "AnLG"(Analog output) of the function of output 2 only.
* When selecting "Out"(control output) of the function of output 2 only.
When selecting an PNP output
M12 Connector Cable (Optional) Pin Position
(Output 1)
4 to 20 mA*
(Output 2)*
0 V
0 V
10-30 VDC
10-30 VDC
1
1
1
2
2
2
3
3
3
4
4
1
2
3
4
0 V
10-30 VDC
(Output 1)
(Output 2)*
Mai
n ci
rcui
tM
ain
circ
uit
Ove
rcur
rent
pro
tect
ion
circ
uit
Load
Load
Load
Load
Mai
n ci
rcui
t
Ove
rcur
rent
pro
tect
ion
circ
uit
Analog input device
Analog current output circuit
11
Out
put
Sensor
GP-M001/M010/M025/M100/M250/M400
Adapter - male
OP-87280/87281/87282/87284/87285Adapter - female
OP-87283
O-ring* for GP-M001/M010/M025 use (OP-87287)
O-ring set* for GP-M100/M250/M400 use (OP-87288)
ø19.5
ø0.77"
ø22.5ø0.89"
1.50.06"
A
A-A Material: FKM
A
Detecting elementø11 ø0.43" depth 1.2 0.05" (GP-M001/M010/M025)ø7 ø0.28" depth 2.9 0.11" (GP-M100/M250/M400)
ø30 ø1
.18"
1.06"27
1.644.3
ø34.2ø1.35" 1.76"
1.08"17.10.67"
15.40.61"
0.10"2.6
Valid screw depth:10 0.39"G3/4A
M12, P=1.0
86.7
*
44.6
27.5
29.21.15"0.06"
1.74"
ø12.8 ø0.50"
ø8ø0.32"
ø15ø0.59"
Material: FKM (O-ring)/PTFE (backup ring)
* O-ring/O-ring set is included with the sensor. They are available as OP-87287/87288 when purchasing separately for replacement.
A-A
A
1.9 2.40.07" 0.09"
A
A
CB
øE
D
R or NPT
Valid thread depth:10
G3/4
Valid thread depth:4.3
M6
Material: SUSXM7 (adapter)
G
øF
Sensor + adapter
Material: FKM
* When replacing the O ring for OP-87283, it is available as OP-87310. Material: SUS303Material: SUS303
Sensor + OP-87283
Valid thread depth:12.3
35.41.39" 1.06"
1421.40.55"0.84"
Valid thread depth:10G3/4
ø34ø1.34"
Valid thread depth:1.8G1/4
M6
Material: SUS303
27
Dedicated throttle (optional)OP-87311
Dedicated throttle (optional)OP-87312
72.42.86"
H
1.76"44.6
301.18"
107.74.24"
ø17.6
ø14ø0.55"
A-A
A
O-ring (included)*
1.80.07"
A
A
A
A-Aø0.5ø0.02"
ø3ø0.12"
(0.4)(0.02")
1.60.06"
1.2
30.12" 0.12"
3
M6×P0.75
M6×P0.75
1.20.05"
0.05"
0.17"
1.2
4.2
1.20.05"
0.05"
ø0.5ø0.02" ø0.69"
There is no air hole on the GP-M100/M250/M400*
(ø6)(ø0.24")ø10
ø0.39"
3.41"
0.39"
0.17"
0.39"
0.07"
0.48"
301.18"
1.76"44.6
72.42.86"
D I M E N S I O N S
12
Model OP-87281 OP-87282 OP-87280 OP-87284 OP-87285
Screw G3/4×R1/8 G3/4×R1/4 G3/4×R3/8 G3/4×NPT1/8 G3/4×NPT1/4
A 43.3 1.70" 47.1 1.85" 47.6 1.87" 43.3 1.70" 47.1 1.85"
B 21.1 0.83" 21.1 0.83" 21.1 0.83" 21.1 0.83" 21.1 0.83"
C 13 0.51" 13 0.51" 13 0.51" 13 0.51" 13 0.51"
D 9.2 0.36" 13 0.51" 13.5 0.53" 9.2 0.36" 13 0.51"
E 34 1.34" 34 1.34" 34 1.34" 34 1.34" 34 1.34"
F 3.7 0.15" 4.8 0.19" 5 0.20" 3.7 0.15" 4.8 0.19"
G 17 0.67" 17 0.67" 19 0.75" 17 0.67" 17 0.67"
H 115.7 4.56" 119.5 4.70" 120 4.72" 115.7 4.56" 119.5 4.70"
Tee adapter
OP-87286
Protective cover
OP-87289
M12 connector cable PVC (vinyl chloride)
OP-75721/87272/85502
M12 connector cable PUR (polyurethane)
OP-87636/88067/87637
OP-75722/87273/87274 OP-87640/88068/87641
341.34"
ø12ø0.47"
G3/4
33
441.73"
19.50.77"
ø39ø1.54"
331.30" 1.30"
391.54"
14.60.57"
24.50.96"
ø8ø0.32"
Material: SUS304
Rc1/2
Sensor + OP-87286
301.18"
116.44.58"
72.42.86"
662.60"
44.61.76"
ø4 (4×0.28mm2)
ø14ø0.55"
ø12ø0.47"
ø0.16"
ø0.16"
ø0.19"
13.70.54"
1.18"
78.74" 196.85" 393.7"
78.74" 196.85" 393.7"
30
2000(OP-75721)/5000(OP-87272)/10000(OP-85502)
Pin
4
3
2
No.
1
Black
White
Blue
Color
Brown3
41
2
2000(OP-75722)/5000(OP-87273)/10000(OP-87274)
ø4 (4×0.20mm2)
28.2
ø14
33.81.33"
ø34.5ø1.36"
ø11ø0.43"
18
159 0.35" 1.5
0.06"
15 0.59"7
0.28"
ø39.8ø1.57"
53.52.11"
Material: Polysulfone (PSF)
Unit: mm inch
Pin
4
3
2
No.
1
Black
White
Blue
Color
Brown3
41
2
0.59"
0.71"
ø0.55"
1.11"
78.74" 196.85" 393.7"
2000(OP-87636)/5000(OP-88067)/10000(OP-87637)44
ø14.8
1.73"
ø0.58"
ø4.7 ø0.19" (4×0.34 mm2)
M12
2000(OP-87640)/5000(OP-88068)/10000(OP-87641)8°
34.5
1.36"
27.41.08"
ø14.8 ø0.58"
ø4.7 (4×0.34 mm2)
M12
78.74" 196.85" 393.7"
13
SAFETY INFORM AT ION FOR GP-M SER IESGeneral precautions
Precautions when installing
Caution when handling
Other precautions
Attaching the coupling
Grounding of metal parts
Other precautions
Do not use this product for the purpose of protecting a human body or a part of human body.
This product is not intended for use as an explosion-proof product. Do not use this product in hazardous locations and/or potentially explosive atmospheres.
The GP-M Series is not designed to sanitary specifications. Do not use the product for applications such as drinks, foods, or medical liquids.
Do not use the GP-M Series for applications requiring safety measures, such as any nuclear, railroad, aircraft, vehicle, orplayground equipment.
1.
2.
3.
4.
5.
6.
7.
The power ON reset time for the GP-M Series is 2 seconds after power is turned on. Do not use outputs from the sensor during this period.
Initial drift may occur after supplying power to the GP-M Series. To detect a minute difference in the pressure, let the GP-M Series warm up for approximately 15 to 30 minutes.
Do not bring a strong magnet or magnetic field close to the main body of the GP-M Series.
Do not remove the seal of the air hole of the GP-M001/M010/M025. It will no longer be waterproof.
When conducting maintenance, use a soft brush so as not to damage items such as the detection surface or the O ring.
When replacing the O ring, clean all of the debris from the surface that will be in contact with the O ring.
Condensation may cause measurement failure or breakage. To prevent this, take the following measures:• Make sure the ambient temperature is same as the fluid temperature or less.
• Use an A/C for dehumidification.• Keep the cooling pipe away from the sensor by 30 cm 11.81" or more using a connecting pipe.
The recommended ambient temperatures and relative humidities are within the highlighted area of the graph below.
The recommended tightening torque when installing the adapter to the main body of the sensor is 20 N•m. It is recommended to apply grease to the G3/4 threaded part in order to avoid thread damage.
• Regardless of whether the power of the device is ON orOFF, do not touch the main part of the pressure detector. If the pressure detector is touched, damage may occur due to static electricity.
• If using a non-conductive liquid such as oil with plastic piping, the risk of an offset changewill become greater. In such a case, it is recommended to ground the metal housing.
• In the case that noise causes malfunction, grounding the metal housing may improve performance.• After installation, conduct an atmospheric correction by making the applied pressure the same as
regular room pressure.• When condensation occurs on piping, place the cooling pipe away from the sensor by 30 cm 11.81"
or more using a connecting pipe.
The metal parts of the main body and the internal circuits are 0 V insulated.
You must verify that the GP-M Series is operating correctly in terms of functionality and performance before the start and operation of the GP-M Series.
We recommend that you take all the necessary safety measures to avoid any damage in the unlikely event of a problem occurring.
Do not use the GP-M Series with corrosive liquids.
We cannot guarantee the functions and/or performance in the event that the product is used outside the standards of the specification, or if the product is modified.
When using our product in combination with another product, based on such factors as conditions of use and surrounding environment, sometimes functions and performance may not be fully realized. In such a case, use after adequate examination.
Piping
• Use the adapter to match the diameter of the piping.• When using the adapter, fit the O ring attached to the main body
to the screw threads of the Adapter G3/4. (Refer to the diagram below.)
• When using a self-made adapter instead of the optional adaptor, or when attaching the main body directly to piping or the tank, specific steps are needed in order to fit the GP-M Series and O ring to the equipment. Please contact KEYENCE for details.
• The body may be rotated horizontally to 330°. When rotating, hold the clasp in place with a wrench.
GP-M001/M010/M025
Adapter
GP-M100/M250/M400
Adapter
O Ring
Adapter (Example when using OP-87281)
CAUTION
CAUTION
CAUTION
When detecting the temperature of the fluid, the housing of the product will be hot, and there is the danger of a burn injury. Do not touch the metal housing while the product is in operation.
The screw part of the main unit is sharp, take care to avoid injury.
Do not drop or hit the device, and avoid any other large shock to the device.
Do not use a sharply pointed object to press the setting keys.
If the detection portion is pushed with a sharp object, damage may occur to the detection surface. Also, for devices where the measuring range is low, the detection portion is thin and easy to break. Touch as little as possible.
1.
2.
3.
4.
1.
2.
3.
1.
2.
1.
2.
1.
2.3.
Ambient temperature (°C °F)
Rel
ativ
e hu
mid
ity
(%R
H)
032 68 104 140 176
0102030405060708090
20 40 60 80
30 cm 11.81" or more
Cooling pipe
WARNING
NOTICE
NOTICE
P I P ING/INSTAL L AT ION
14
* 2 outputs for ON/OFFSwitchable between analog output (4 – 20 mA) and zero shift input
DIN-rail mount type
Stainless steel pressure element (diaphragm)
Full stainless steel structure 2 types of displays are available Can detect up to 7250 PSI.
Panel mount type
Differential pressure type amplifiers are used with two sensor heads of the same model in order to detect differences in the pressures measured by the two sensor heads.
TypeModel
NPN output PNP output
StandardDIN AP-V80W AP-V80WP
Panel AP-V85W AP-V85WPDifferential pressure
DIN AP-V82W AP-V82WPPanel AP-V87W AP-V87WP
Rated pressure range Display resolution (default setting)
Pressure resistance Pressure port Model
Compound pressure
-29.9 to +29.9 inchHg(-100 to +100 kPa)
0.1 inchHg(0.1 kPa)
72.5 PSI(500 kPa)
NPT 1/8
AP-10SK
Negative pressure
-29.9 to 0 inchHg(-100 to 0 kPa) AP-11SK
Positive pressure
0 to 14.5 PSI(0 to 100 kPa) AP-12SK
0 to 145 PSI(0 to 1 MPa)
0.1 PSI(0.001 MPa)
290 PSI (2.0 MPa) AP-13SK
0 to 1450 PSI(0 to 10 MPa)
1 PSI(0.01 MPa)
2900 PSI(20 MPa)
NPT 1/4(with a throttle)
AP-14SK
0 to 2900 PSI(0 to 20 MPa)
10 PSI(0.1 MPa)
5800 PSI(40 MPa) AP-15SK
0 to 7250 PSI(0 to 50 MPa)
10 PSI(0.1 MPa)
10875 PSI (75 MPa) AP-16SK
VARIATION
For oil, water, and air (Separate amplifier type)
Detects a variety of fluids, including water, oil, and air.
KEYENCE OFFERS VAR IOUS OTHER MODELS FOR PRESSURE DETECT ION
Environmental resistance pressure sensor
AP-V80W Series
For water flow
NO OBSTRUCTIONSNO PADDLE WHEELSNO ELECTRODES
New flow sensor with free flowing pipe
FD-M Series
LOWERS MAINTENANCEDramatically reduces cloggingUnlike general floating element and paddle wheel flow meters, the FD-M Series has a "free flowing structure" that is completely free of moving parts and obstructions. There is no trouble with dirt and rust clogging the mechanical parts, greatly reducing maintenance.
LONG L IFESPANNo damage from moving partsDue to the absence of moving parts, it does not experience axial wear or other types of mechanical wear. Through its “free flowing structure” the FD-M Series has achieved a significantly longer lifespan.
ENERGY SAVINGDramatically reduces pressure lossDue to its “free flowing structure”, the FD-M Series has almost no pressure loss. Does not apply a large load on pumps and thus saves energy.
*1 Twice the rated flow range can be displayed.
Model
FD-MZ10ATKFD-MZ10ATKPFD-MZ10AYKFD-MZ10AYKPFD-MZ50ATKFD-MZ50ATKPFD-MZ50AYKFD-MZ50AYKPFD-MZ100ATKFD-MZ100ATKPFD-MZ100AYKFD-MZ100AYKP
Applicable fluid
Detecting range*1Bore
diameterPipe direction Output
Rated rangeDisplay range
Water, noncorrosive liquid (electrical conductivity: 5 µS/cm or more)
0.14 - 7.50 G/min (0.50 - 30 L/min)
0.7 - 26.4 G/min (2.5 - 100 L/min)
1.4 - 52.8 G/min (5.0 - 200 L/min)
0.14 - 2.60 G/min (0.50 - 10 L/min)
0.7 - 13.0 G/min (2.5 - 50 L/min)
1.4 - 26.0 G/min (5.0 - 100 L/min)
Vertical
Horizontal
Vertical
Horizontal
Vertical
Horizontal
NPNPNPNPNPNPNPNPNPNPNPNPNPNPNPNPNPNP
NPT3/8(10A)
NPT3/4(20A)
NPT1(25A)
LINEUP
15
Ampl
ifier
Sens
or h
ead
* 2 outputs for ON/OFF. Switchable between analog output (1 – 5V) and zero shift input
CompactDisplay can be installed in easily viewable locations
TypeModel
NPN output PNP output
DIN rail mount type
Main unit AP-V41AW AP-V41AWP
Expansion unit AP-V42AW AP-V42AWP
CUBE AP-C40W AP-C40WP
Rated pressure range Display resolution(factory setting)
Proofpressure Model
Negative pressure 0 to -29.9 inchHg(0 to −101.3 kPa) 0.1 inchHg
(0.1 kPa) 500 kPa
AP-41MAP-41
Compound pressure +29.9 to -29.9 inchHg (+101.3 to −101.3 kPa) AP-44
Positive pressure 0 to 145.0 PSI (0 to 1 MPa)
0.01 kgf/cm2
(0.001 MPa) 1.5 MPa AP-43
VARIATION
VARIATION
* Switchable between the negative pressure mode 0 to -29.9 inchHg (0 to -101.3 kPa) and positive pressure mode -29.9 to 0 inchHg (0 to +100 kPa)
Sensor (cable length: 2 m 6.56')
Rated pressure range Display resolution (factory setting)
Proofpressure
ModelNPN output PNP output
+29.9 to -29.9 inchHg(+101.3 to −101.3kPa*) 0.1 inchHg (0.2 kPa)
72.5 PSI(500 kPa)
AP-C30K -
0 to -29.9 inchHg(0 to −101.3 kPa)
0.1 inchHg (Normal mode) (0.1 kPa) AP-C31K AP-C31KP
0 to +145 PSI(0 to +1.000 MPa)
0.2 PSI (Normal mode)(0.001 MPa)
217.5 PSI(1.5 MPa) AP-C33K AP-C33KP
2 color LED Connecting to the connector Rotating pressure port
Gas
2 color LED
Built-in amplifier pressure sensor
AP-C30K Series
Compact gas pressure sensor
KEYENCE OFFERS VAR IOUS OTHER MODELS FOR PRESSURE DETECT ION
Separate amplifier pressure sensor
AP-C/V40W Series
Faster response than the built-in amplifier type
Loss of response time due to air tube length can be eliminated.
Separate amplifier type
EjectorAP-C40W
Target
Ampl
ifier
Sens
or h
ead
www.keyence.com
GPM-KA-C-US 1036-9 611551 Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.
E-mail: [email protected]
E-mail: [email protected] E-mail: [email protected]