heavy duty industrial pressure sensor€¦ · throttle (attach to the adapter before use.) o-ring...

16
Heavy Duty Industrial Pressure Sensor For Hydraulic and Pneumatic Applications STEP FLUSH DIAPHRAGM Standard equipment Actual size GP - M Series RUGGED, VERSATILE, AND HIGHLY VISIBLE Easy to See Easy to Mount Heavy Duty Digital Pressure Sensors GP-M Series

Upload: others

Post on 26-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

Heavy Duty Industrial Pressure Sensor

For Hydraulic and Pneumatic Applications

STEP FLUSH DIAPHRAGMStandard equipment

Actual size

GP-M Series

RUGGED, VERSATILE, AND HIGHLY VISIBLE

180°Back side

Easy to See Easy to Mount

Heavy Duty Digital Pressure SensorsGP-M Series

Page 2: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

OIL, WATER, and AIR…

One sensor with the ability to solve a wide variety of applications

Easy to program

Easy to mount

Easy to monitor

Resistant to damage

Fluidtemperature range

-20 to+100°C-4 to+212°F

Vibration resistance

20G

Shock resistance

50G

2

Page 3: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

New Standard in user-friendly operation to solve a wide range of applications

1

2

3

Easy to use

New features include the easy to clean,

clog resistant structure and a highly visible

indicator and display. In combination with

its intuitive operation, the GP-M provides the

next level of ease-of-use functionality.

Its hex-shaped design, rotatable display, and

user-friendly setup simplify the installation.

With six different models available, the

GP-M can be used for almost any pressure

application. Its standard footprint for all

models simplifies integration.

Easy to install

Easy to select

The flat surface diaphragm is easy to clean and resists clogging.

only 1size for all 6 models

330°

THE NEW STANDARD FOR VERSATILE

AND RUGGED PRESSURE SENSORS

GP-MSeries

3

Page 4: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

Highly Visible Indicators & DisplayEasy to see operation status from any viewing direction

Overhead mounting

Rear facing

Front facing

Low level mounting

1 Easy to use

4

Page 5: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

5

Clog resistant. No disassembly required for cleaning.STEP FLUSH DIAPHRAGM DESIGN

The GP-M features a step flush diaphragm design that prevents foreign materials from clogging the unit.

Large Display Easy to see the current operation status from any viewing direction.

Back side180°

Inverse display functionThe digitial display can be inverted 180 degrees, which allows installation in nearly any orientation.

Prevent unauthorized changesKey Lock and Password Protection settings are available to prevent unauthorized changes from being made.

Easy MaintenanceClogging inside of the sensor may lead to a delayed response or errors in detection values. The GP-M can be removed and cleaned when couplings or other connecting parts become clogged. The step flush diaphragm design simplifies debris removal.

Conventional: Bourdon tube & Mechanical type・Values are difficult to understand

・Require more space due to large size

・More potential for leaks and damage

・No outputs provided

GP-M Series・Anyone can understand the large numerical display

・Outputs can easily be seen at a glance from any direction

・Space-saving design

・Includes an adjustable range analog function.

Advantage of using digital pressure sensor

Page 6: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

The sensor display can be rotated after mounting the sensor

330°

3 SIMPLE STEPS FOR INSTALLATION

Rotating

Mount the sensor to the coupling1

CONVENTIONAL INSTALLATION

Sensor

Union

Additional part added

* Researched by KEYENCE

1.57"

Space saving is possible because the union is unnecessary

Up to

40mm

increase in height

2 Easy to install

Fixed

Adjust the display orientation2 Attach the cable3

Installation does not require a union in order to adjust the display orientation. Therefore, the number of parts can be reduced by eliminating the need for this adapter.

Rotating head = No union required

6

Page 7: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

GP-M001 -14.50 to +14.50 PSI (-100 to +100 kPa)

GP-M010 -14.5 to +145.0 PSI (-0.1 to +1 MPa)

GP-M025 -14.5 to +362.6 PSI (-0.1 to +2.5 MPa)

GP-M100 0 to +1450 PSI (0 to +10 MPa)

GP-M250 0 to +3626 PSI (0 to +25 MPa)

GP-M400 0 to +5802 PSI (0 to +40 MPa)

Rugged durability and environmental resistance

1 2 3Sensor Cable Adapter

NPTR

Tee Rc

G

NPN/PNP selectable

Selectable between [2 outputs] or [1 output + analog output]

Range Selection

0 PSI0 MPa

ø34.2 mm1.35"

3.41"86.7 mm

M124pin

G 43

SUSXM7

Al2O3

(Alumina)

TOUGH &HEAVY-DUTY

High chemical resistance and hardness

AluminaCeramic diaphragm:

Straight type

L-shaped type

• It is recommended to attach a throttle (KEYENCE optional accessory) when an exceptionally large pulse or surge pressure is expected.

* No freezing or condensation

3 Easy to select

Simple lineup

Various cables and adapteraccessories are available

50G

Shockresistance

-20 to+100°C*-4 to+212°F

Fluid temperature range

20G

Vibrationresistance

150g

Light weight

7

Page 8: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

A P P L I C AT I O N S

With its wide pressure range, from -14.5 to +5802 PSI (−0.1 to +40 MPa), and ceramic (alumina) diaphragm with high oil resistance, the GP-M Series can inspect pressure in a variety of applications.

The step flush diaphragm, with its small indentation inside of the sensor, prevents liquid and bubbles from easily clogging the pipe. In addition, it is easy to remove this sensor for cleaning. Users should consider the GP-M Series for fluids that commonly result in clogging.

The GP-M Series can monitor fluids between -20 and +100°C -4 and +212°F and can therefore be used in a wide variety of applications ranging from cooling, heat retention, and sterilization. (Ensure that the environment is free from freezing or condensation.)

OIL PRESSURE

Thick fluid, fluid-containing powdersand foreign materials

Fluid between -20 and +100°C -4 and +212°F

Machine tools

Work clamp pressure

Coolant discharge pressure

Checking workpiece setting

Monitoring clogging of waste liquid containing contaminants

Fluid examples

Grease

Coating material

Adhesive

Flux

Sealant

Applications at high temperatures

Clogging of a strainer

Checking back pressure of a steam trap

Water pressure for antiseptic wash

8

Page 9: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

SEL ECTAB LE FUNCT IONS ACCORD ING TO THE APP L ICAT ION

Initial setting of the hysteresis mode (Hno/Hnc)

2 3 4 51

FH

FL

Hysteresis

FnoFnC

Hysteresis

1rP

SP

HnoHnC

2 3

Free range analog Hold function

Window mode (Fno/Fnc)

Pressure is likely to fluctuate from factors such as pressure spikes. This mode allows for free adjustment of hysteresis in order to prevent chattering due to fluctuating pressure.

The data is output within the range of 4 to 20 mA in correspondence with the upper and lower limit values of the required pressure range. The pressure range can be adjusted as desired to maximize resolution.

This function displays the peak value and bottom value measured since the GP-M Series was turned on. Users can check the peak and bottom values easily by quickly pressing the ▲ or ▼ button while pressing the MODE button.

This mode is used to judge whether or not a measurement value is inside or outside of a specified zone.

Assume that SP-rP = Hysteresis

The mode turns ON when a measurement value rises above SP.

The mode turns ON when a measurement value rises above FL + Hysteresis.

The mode turns OFF when a measurement value rises above FH.

The mode turns ON when a measurement value falls below FH – Hysteresis.

The mode turns OFF when a measurement value falls below FL.

The mode turns OFF when a measurement value falls below rP. 2 3

Hysteresis

* The “hysteresis mode” and “window mode” can be selected for control outputs 1 and 2 respectively.

1 2

1 2

2 3

3 4

4 5

Response speed (chattering prevention)

This function ignores rapid changes due to such factors as pressure spikes by increasing the response time. The time can be adjusted from 3 to 5000 ms.

9

Page 10: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

Specifications Model Material Connector type Cable termination Length (m ft)

Standard

OP-75721

PVC

(Vinyl chloride)

M12 4 pinsStraight

Loose wire

2 6.56'

OP-87272 5 16.40'

OP-85502 10 32.81'

OP-75722

M12 4 pinsL-shape

2 6.56'

OP-87273 5 16.40'

OP-87274 10 32.81'

OIil-resistant

OP-87636

PUR

(Polyurethane)

M12 4 pinsStraight

2 6.56'

OP-88067 5 16.40'

OP-87637 10 32.81'

OP-87640

M12 4 pinsL-shape

2 6.56'

OP-88068 5 16.40'

OP-87641 10 32.81'

Appearance Model Rated pressure range Fluid type Thread diameter

GP-M001 -14.50 to +14.50 PSI (-100 to +100 kPa)

GasLiquid

G3/4

GP-M010 -14.5 to +145.0 PSI (-0.1 to +1 MPa)

GP-M025 -14.5 to +362.6 PSI (-0.1 to +2.5 MPa)

GP-M100 0 to +1450 PSI (0 to +10 MPa)

LiquidGP-M250 0 to +3626 PSI (0 to +25 MPa)

GP-M400 0 to+5802 PSI (0 to +40 MPa)

Appearance Model Type

OP-87281 R male 1/8

OP-87282 R male 1/4

OP-87280 R male 3/8

OP-87283 G female 1/4

OP-87284 NPT male 1/8

OP-87285 NPT male 1/4

OP-87286 Rc female 1/2

Appearance Model Material

OP-87289 Polysulfone

Appearance Model Material

OP-87310 FKM

Appearance Model Material Applicable adapter

OP-87311 SUS303OP-87280/OP-87281OP-87282/OP-87284

OP-87285

OP-87312 SUS303 OP-87283

Appearance Model Material

OP-87287 FKM

Appearance Model Material

OP-87288O-ring: FKM

Backup ring: PTFE

L I N E U P

Display protection cover

O-ring (for OP-87283)

Throttle (Attach to the adapter before use.)

O-ring (for GP-M001/M010/M025)

O-ring set (for GP-M100/M250/M400)

0

Use the set in combination: O-ring (black) and the backup ring (white)

It is recommended to attach a throttle to the GP-M100/M250/M400. For the other models, use it when excessive pulses or surge pressure is expected.

Do not use unauthorized items. Refer to Page 14 "PIPING/INSTALLATION" for details.

Replacement parts (Available for the following model numbers. Sold separately.)

1 Sensor

2 Cable

3 Adapter (Select from the following adapters.)

10

Page 11: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

Model GP-M001 GP-M010 GP-M025 GP-M100 GP-M250 GP-M400

Rated pressure -14.50 to +14.50 PSI (-100 to +100 kPa)

-14.5 to +145.0 PSI (-0.1 to +1 MPa)

-14.5 to +362.6 PSI (-0.1 to +2.5 MPa)

0 to +1450 PSI (0 to +10 MPa)

0 to +3626 PSI (0 to +25 MPa)

0 to+5802 PSI(0 to+40 MPa)

Possible display range -17.40 to +17.40 PSI (-120.0 to +120.0 kPa)

-30.5 to +161.0 PSI (-0.210 to +1.110 MPa)

-52.2 to +400.3 PSI (-0.360 to +2.760 MPa)

-145 to +1595 PSI (-1.00 to +11.00 MPa)

-363 to +3989 PSI (-2.50 to +27.50 MPa)

-580 to+6382 PSI(-4.00 to+44.00 MPa)

Zero-cut pressure value ±0.5% of F.S.

Allowable pressure 58 PSI (400 kPa) 580 PSI (4 MPa) 1450 PSI (10 MPa) 4351 PSI (30 MPa) 7252 PSI (50 MPa) 7252 PSI (50 MPa)

Burst pressure 217.5 PSI (1500 kPa) 2175 PSI (15 MPa) 5075 PSI (35 MPa) 14504 PSI (100 MPa) 14504 PSI (100 MPa) 14504 PSI (100 MPa)

Display resolution

kPa 0.1 1 1 None None None

MPa None 0.001 0.001 0.01 0.01 0.01

PSI 0.01 0.1 0.1 1 1 1

bar 0.001 0.01 0.01 0.1 0.1 0.1

kgf/cm2 0.001 0.01 0.01 0.1 0.1 0.1

Fluid type Gas or liquid that will not corrode the liquid contact part Liquid that will not corrode the liquid contact part

Type of pressure Gage pressure

Precision*1 ±1.0% of F.S. or less

Repeatability*2 ±0.3% of F.S. or less

Temperature characteristics ±0.6% of F.S./10°C 50°F

Connection port G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle Maximum 330°

Medium temperature -20 to +100°C -4°F to +212°F (no freezing/condensation)*3 *6

Power voltage 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method 4 column, digital LED, red/Vertical inversion display possible

Operation display light Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)During window mode: fixed (0.5% of F.S.)

ResponseControl output Selectable from 3 to 5000 ms

Analog output As above + 2 ms (90% response)

Output 1 control output NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)Main unit residual voltage 1 V max,N.O./N.C. selectableOutput 2

replacement typeControl output

Analog output 4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmentalresistance

Ambient temperature -20 to +80°C -4°F to +176°F (no freezing/condensation)*6

Relative humidity 35 to 85% RH (no condensation)*6

Vibration IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)

Shock IEC60068-2-27 50 G (11 ms, 3 times for each of X, Y and Z axis)

Enclosure rating IP67

Materialproperties

Wetted part Pressure port: SUSXM7, Diaphragm pressure port: Al2O3(Alumina), O ring: FKM

Other parts Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole*7: PTFE, nickel-plated brass.

Applicable cable M12 connector 4 pin

Weight App. 150 g

S P E C I F I C AT I O N S

W I R I N G, O U T P U T D I A G R A MWhen selecting an NPN output

Analog output diagram

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.*4 Consumption current including output is 0.6 A and under.*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = (38 × (E-10) + 128) Ω When 23-30V: R = 622 Ω*6 For measures to prevent condensation, refer to Page 14 "Other precautions" 7.*7 Only for the GP-M001/M010/M025

* When selecting "Out"(control output) of the function of output 2 only.

* When selecting "AnLG"(Analog output) of the function of output 2 only.

* When selecting "Out"(control output) of the function of output 2 only.

When selecting an PNP output

M12 Connector Cable (Optional) Pin Position

(Output 1)

4 to 20 mA*

(Output 2)*

0 V

0 V

10-30 VDC

10-30 VDC

1

1

1

2

2

2

3

3

3

4

4

1

2

3

4

0 V

10-30 VDC

(Output 1)

(Output 2)*

Mai

n ci

rcui

tM

ain

circ

uit

Ove

rcur

rent

pro

tect

ion

circ

uit

Load

Load

Load

Load

Mai

n ci

rcui

t

Ove

rcur

rent

pro

tect

ion

circ

uit

Analog input device

Analog current output circuit

11

Out

put

Page 12: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

Sensor

GP-M001/M010/M025/M100/M250/M400

Adapter - male

OP-87280/87281/87282/87284/87285Adapter - female

OP-87283

O-ring* for GP-M001/M010/M025 use (OP-87287)

O-ring set* for GP-M100/M250/M400 use (OP-87288)

ø19.5

ø0.77"

ø22.5ø0.89"

1.50.06"

A

A-A Material: FKM

A

Detecting elementø11 ø0.43" depth 1.2 0.05" (GP-M001/M010/M025)ø7 ø0.28" depth 2.9 0.11" (GP-M100/M250/M400)

ø30 ø1

.18"

1.06"27

1.644.3

ø34.2ø1.35" 1.76"

1.08"17.10.67"

15.40.61"

0.10"2.6

Valid screw depth:10 0.39"G3/4A

M12, P=1.0

86.7

*

44.6

27.5

29.21.15"0.06"

1.74"

ø12.8 ø0.50"

ø8ø0.32"

ø15ø0.59"

Material: FKM (O-ring)/PTFE (backup ring)

* O-ring/O-ring set is included with the sensor. They are available as OP-87287/87288 when purchasing separately for replacement.

A-A

A

1.9 2.40.07" 0.09"

A

A

CB

øE

D

R or NPT

Valid thread depth:10

G3/4

Valid thread depth:4.3

M6

Material: SUSXM7 (adapter)

G

øF

Sensor + adapter

Material: FKM

* When replacing the O ring for OP-87283, it is available as OP-87310. Material: SUS303Material: SUS303

Sensor + OP-87283

Valid thread depth:12.3

35.41.39" 1.06"

1421.40.55"0.84"

Valid thread depth:10G3/4

ø34ø1.34"

Valid thread depth:1.8G1/4

M6

Material: SUS303

27

Dedicated throttle (optional)OP-87311

Dedicated throttle (optional)OP-87312

72.42.86"

H

1.76"44.6

301.18"

107.74.24"

ø17.6

ø14ø0.55"

A-A

A

O-ring (included)*

1.80.07"

A

A

A

A-Aø0.5ø0.02"

ø3ø0.12"

(0.4)(0.02")

1.60.06"

1.2

30.12" 0.12"

3

M6×P0.75

M6×P0.75

1.20.05"

0.05"

0.17"

1.2

4.2

1.20.05"

0.05"

ø0.5ø0.02" ø0.69"

There is no air hole on the GP-M100/M250/M400*

(ø6)(ø0.24")ø10

ø0.39"

3.41"

0.39"

0.17"

0.39"

0.07"

0.48"

301.18"

1.76"44.6

72.42.86"

D I M E N S I O N S

12

Model OP-87281 OP-87282 OP-87280 OP-87284 OP-87285

Screw G3/4×R1/8 G3/4×R1/4 G3/4×R3/8 G3/4×NPT1/8 G3/4×NPT1/4

A 43.3 1.70" 47.1 1.85" 47.6 1.87" 43.3 1.70" 47.1 1.85"

B 21.1 0.83" 21.1 0.83" 21.1 0.83" 21.1 0.83" 21.1 0.83"

C 13 0.51" 13 0.51" 13 0.51" 13 0.51" 13 0.51"

D 9.2 0.36" 13 0.51" 13.5 0.53" 9.2 0.36" 13 0.51"

E 34 1.34" 34 1.34" 34 1.34" 34 1.34" 34 1.34"

F 3.7 0.15" 4.8 0.19" 5 0.20" 3.7 0.15" 4.8 0.19"

G 17 0.67" 17 0.67" 19 0.75" 17 0.67" 17 0.67"

H 115.7 4.56" 119.5 4.70" 120 4.72" 115.7 4.56" 119.5 4.70"

Page 13: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

Tee adapter

OP-87286

Protective cover

OP-87289

M12 connector cable PVC (vinyl chloride)

OP-75721/87272/85502

M12 connector cable PUR (polyurethane)

OP-87636/88067/87637

OP-75722/87273/87274 OP-87640/88068/87641

341.34"

ø12ø0.47"

G3/4

33

441.73"

19.50.77"

ø39ø1.54"

331.30" 1.30"

391.54"

14.60.57"

24.50.96"

ø8ø0.32"

Material: SUS304

Rc1/2

Sensor + OP-87286

301.18"

116.44.58"

72.42.86"

662.60"

44.61.76"

ø4 (4×0.28mm2)

ø14ø0.55"

ø12ø0.47"

ø0.16"

ø0.16"

ø0.19"

13.70.54"

1.18"

78.74" 196.85" 393.7"

78.74" 196.85" 393.7"

30

2000(OP-75721)/5000(OP-87272)/10000(OP-85502)

Pin

4

3

2

No.

1

Black

White

Blue

Color

Brown3

41

2

2000(OP-75722)/5000(OP-87273)/10000(OP-87274)

ø4 (4×0.20mm2)

28.2

ø14

33.81.33"

ø34.5ø1.36"

ø11ø0.43"

18

159 0.35" 1.5

0.06"

15 0.59"7

0.28"

ø39.8ø1.57"

53.52.11"

Material: Polysulfone (PSF)

Unit: mm inch

Pin

4

3

2

No.

1

Black

White

Blue

Color

Brown3

41

2

0.59"

0.71"

ø0.55"

1.11"

78.74" 196.85" 393.7"

2000(OP-87636)/5000(OP-88067)/10000(OP-87637)44

ø14.8

1.73"

ø0.58"

ø4.7 ø0.19" (4×0.34 mm2)

M12

2000(OP-87640)/5000(OP-88068)/10000(OP-87641)8°

34.5

1.36"

27.41.08"

ø14.8 ø0.58"

ø4.7 (4×0.34 mm2)

M12

78.74" 196.85" 393.7"

13

Page 14: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

SAFETY INFORM AT ION FOR GP-M SER IESGeneral precautions

Precautions when installing

Caution when handling

Other precautions

Attaching the coupling

Grounding of metal parts

Other precautions

Do not use this product for the purpose of protecting a human body or a part of human body.

This product is not intended for use as an explosion-proof product. Do not use this product in hazardous locations and/or potentially explosive atmospheres.

The GP-M Series is not designed to sanitary specifications. Do not use the product for applications such as drinks, foods, or medical liquids.

Do not use the GP-M Series for applications requiring safety measures, such as any nuclear, railroad, aircraft, vehicle, orplayground equipment.

1.

2.

3.

4.

5.

6.

7.

The power ON reset time for the GP-M Series is 2 seconds after power is turned on. Do not use outputs from the sensor during this period.

Initial drift may occur after supplying power to the GP-M Series. To detect a minute difference in the pressure, let the GP-M Series warm up for approximately 15 to 30 minutes.

Do not bring a strong magnet or magnetic field close to the main body of the GP-M Series.

Do not remove the seal of the air hole of the GP-M001/M010/M025. It will no longer be waterproof.

When conducting maintenance, use a soft brush so as not to damage items such as the detection surface or the O ring.

When replacing the O ring, clean all of the debris from the surface that will be in contact with the O ring.

Condensation may cause measurement failure or breakage. To prevent this, take the following measures:• Make sure the ambient temperature is same as the fluid temperature or less.

• Use an A/C for dehumidification.• Keep the cooling pipe away from the sensor by 30 cm 11.81" or more using a connecting pipe.

The recommended ambient temperatures and relative humidities are within the highlighted area of the graph below.

The recommended tightening torque when installing the adapter to the main body of the sensor is 20 N•m. It is recommended to apply grease to the G3/4 threaded part in order to avoid thread damage.

• Regardless of whether the power of the device is ON orOFF, do not touch the main part of the pressure detector. If the pressure detector is touched, damage may occur due to static electricity.

• If using a non-conductive liquid such as oil with plastic piping, the risk of an offset changewill become greater. In such a case, it is recommended to ground the metal housing.

• In the case that noise causes malfunction, grounding the metal housing may improve performance.• After installation, conduct an atmospheric correction by making the applied pressure the same as

regular room pressure.• When condensation occurs on piping, place the cooling pipe away from the sensor by 30 cm 11.81"

or more using a connecting pipe.

The metal parts of the main body and the internal circuits are 0 V insulated.

You must verify that the GP-M Series is operating correctly in terms of functionality and performance before the start and operation of the GP-M Series.

We recommend that you take all the necessary safety measures to avoid any damage in the unlikely event of a problem occurring.

Do not use the GP-M Series with corrosive liquids.

We cannot guarantee the functions and/or performance in the event that the product is used outside the standards of the specification, or if the product is modified.

When using our product in combination with another product, based on such factors as conditions of use and surrounding environment, sometimes functions and performance may not be fully realized. In such a case, use after adequate examination.

Piping

• Use the adapter to match the diameter of the piping.• When using the adapter, fit the O ring attached to the main body

to the screw threads of the Adapter G3/4. (Refer to the diagram below.)

• When using a self-made adapter instead of the optional adaptor, or when attaching the main body directly to piping or the tank, specific steps are needed in order to fit the GP-M Series and O ring to the equipment. Please contact KEYENCE for details.

• The body may be rotated horizontally to 330°. When rotating, hold the clasp in place with a wrench.

GP-M001/M010/M025

Adapter

GP-M100/M250/M400

Adapter

O Ring

Adapter (Example when using OP-87281)

CAUTION

CAUTION

CAUTION

When detecting the temperature of the fluid, the housing of the product will be hot, and there is the danger of a burn injury. Do not touch the metal housing while the product is in operation.

The screw part of the main unit is sharp, take care to avoid injury.

Do not drop or hit the device, and avoid any other large shock to the device.

Do not use a sharply pointed object to press the setting keys.

If the detection portion is pushed with a sharp object, damage may occur to the detection surface. Also, for devices where the measuring range is low, the detection portion is thin and easy to break. Touch as little as possible.

1.

2.

3.

4.

1.

2.

3.

1.

2.

1.

2.

1.

2.3.

Ambient temperature (°C °F)

Rel

ativ

e hu

mid

ity

(%R

H)

032 68 104 140 176

0102030405060708090

20 40 60 80

30 cm 11.81" or more

Cooling pipe

WARNING

NOTICE

NOTICE

P I P ING/INSTAL L AT ION

14

Page 15: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

* 2 outputs for ON/OFFSwitchable between analog output (4 – 20 mA) and zero shift input

DIN-rail mount type

Stainless steel pressure element (diaphragm)

Full stainless steel structure 2 types of displays are available Can detect up to 7250 PSI.

Panel mount type

Differential pressure type amplifiers are used with two sensor heads of the same model in order to detect differences in the pressures measured by the two sensor heads.

TypeModel

NPN output PNP output

StandardDIN AP-V80W AP-V80WP

Panel AP-V85W AP-V85WPDifferential pressure

DIN AP-V82W AP-V82WPPanel AP-V87W AP-V87WP

Rated pressure range Display resolution (default setting)

Pressure resistance Pressure port Model

Compound pressure

-29.9 to +29.9 inchHg(-100 to +100 kPa)

0.1 inchHg(0.1 kPa)

72.5 PSI(500 kPa)

NPT 1/8

AP-10SK

Negative pressure

-29.9 to 0 inchHg(-100 to 0 kPa) AP-11SK

Positive pressure

0 to 14.5 PSI(0 to 100 kPa) AP-12SK

0 to 145 PSI(0 to 1 MPa)

0.1 PSI(0.001 MPa)

290 PSI (2.0 MPa) AP-13SK

0 to 1450 PSI(0 to 10 MPa)

1 PSI(0.01 MPa)

2900 PSI(20 MPa)

NPT 1/4(with a throttle)

AP-14SK

0 to 2900 PSI(0 to 20 MPa)

10 PSI(0.1 MPa)

5800 PSI(40 MPa) AP-15SK

0 to 7250 PSI(0 to 50 MPa)

10 PSI(0.1 MPa)

10875 PSI (75 MPa) AP-16SK

VARIATION

For oil, water, and air (Separate amplifier type)

Detects a variety of fluids, including water, oil, and air.

KEYENCE OFFERS VAR IOUS OTHER MODELS FOR PRESSURE DETECT ION

Environmental resistance pressure sensor

AP-V80W Series

For water flow

NO OBSTRUCTIONSNO PADDLE WHEELSNO ELECTRODES

New flow sensor with free flowing pipe

FD-M Series

LOWERS MAINTENANCEDramatically reduces cloggingUnlike general floating element and paddle wheel flow meters, the FD-M Series has a "free flowing structure" that is completely free of moving parts and obstructions. There is no trouble with dirt and rust clogging the mechanical parts, greatly reducing maintenance.

LONG L IFESPANNo damage from moving partsDue to the absence of moving parts, it does not experience axial wear or other types of mechanical wear. Through its “free flowing structure” the FD-M Series has achieved a significantly longer lifespan.

ENERGY SAVINGDramatically reduces pressure lossDue to its “free flowing structure”, the FD-M Series has almost no pressure loss. Does not apply a large load on pumps and thus saves energy.

*1 Twice the rated flow range can be displayed.

Model

FD-MZ10ATKFD-MZ10ATKPFD-MZ10AYKFD-MZ10AYKPFD-MZ50ATKFD-MZ50ATKPFD-MZ50AYKFD-MZ50AYKPFD-MZ100ATKFD-MZ100ATKPFD-MZ100AYKFD-MZ100AYKP

Applicable fluid

Detecting range*1Bore

diameterPipe direction Output

Rated rangeDisplay range

Water, noncorrosive liquid (electrical conductivity: 5 µS/cm or more)

0.14 - 7.50 G/min (0.50 - 30 L/min)

0.7 - 26.4 G/min (2.5 - 100 L/min)

1.4 - 52.8 G/min (5.0 - 200 L/min)

0.14 - 2.60 G/min (0.50 - 10 L/min)

0.7 - 13.0 G/min (2.5 - 50 L/min)

1.4 - 26.0 G/min (5.0 - 100 L/min)

Vertical

Horizontal

Vertical

Horizontal

Vertical

Horizontal

NPNPNPNPNPNPNPNPNPNPNPNPNPNPNPNPNPNP

NPT3/8(10A)

NPT3/4(20A)

NPT1(25A)

LINEUP

15

Ampl

ifier

Sens

or h

ead

Page 16: Heavy Duty Industrial Pressure Sensor€¦ · Throttle (Attach to the adapter before use.) O-ring (for GP-M001/M010/M025) O-ring set (for GP-M100/M250/M400) 0 Use the set in combination:

* 2 outputs for ON/OFF. Switchable between analog output (1 – 5V) and zero shift input

CompactDisplay can be installed in easily viewable locations

TypeModel

NPN output PNP output

DIN rail mount type

Main unit AP-V41AW AP-V41AWP

Expansion unit AP-V42AW AP-V42AWP

CUBE AP-C40W AP-C40WP

Rated pressure range Display resolution(factory setting)

Proofpressure Model

Negative pressure 0 to -29.9 inchHg(0 to −101.3 kPa) 0.1 inchHg

(0.1 kPa) 500 kPa

AP-41MAP-41

Compound pressure +29.9 to -29.9 inchHg (+101.3 to −101.3 kPa) AP-44

Positive pressure 0 to 145.0 PSI (0 to 1 MPa)

0.01 kgf/cm2

(0.001 MPa) 1.5 MPa AP-43

VARIATION

VARIATION

* Switchable between the negative pressure mode 0 to -29.9 inchHg (0 to -101.3 kPa) and positive pressure mode -29.9 to 0 inchHg (0 to +100 kPa)

Sensor (cable length: 2 m 6.56')

Rated pressure range Display resolution (factory setting)

Proofpressure

ModelNPN output PNP output

+29.9 to -29.9 inchHg(+101.3 to −101.3kPa*) 0.1 inchHg (0.2 kPa)

72.5 PSI(500 kPa)

AP-C30K -

0 to -29.9 inchHg(0 to −101.3 kPa)

0.1 inchHg (Normal mode) (0.1 kPa) AP-C31K AP-C31KP

0 to +145 PSI(0 to +1.000 MPa)

0.2 PSI (Normal mode)(0.001 MPa)

217.5 PSI(1.5 MPa) AP-C33K AP-C33KP

2 color LED Connecting to the connector Rotating pressure port

Gas

2 color LED

Built-in amplifier pressure sensor

AP-C30K Series

Compact gas pressure sensor

KEYENCE OFFERS VAR IOUS OTHER MODELS FOR PRESSURE DETECT ION

Separate amplifier pressure sensor

AP-C/V40W Series

Faster response than the built-in amplifier type

Loss of response time due to air tube length can be eliminated.

Separate amplifier type

EjectorAP-C40W

Target

Ampl

ifier

Sens

or h

ead

www.keyence.com

GPM-KA-C-US 1036-9 611551 Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.

E-mail: [email protected]