applicationsctae.co.th/files/products/hyundai heavy industry p… ·  · 2013-09-27in accordance...

16

Upload: phamthuy

Post on 24-Apr-2018

231 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form
Page 2: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

Commercial

�Airports�Warehouses�Shopping malls�Schools�Hospitals�Office buildings

Industrial

�Printing�Machinery�Pharmaceutical�Automotive, Paper & Pulp�Chemical�Marine

Applications

Utilities

�Water treatment plants�Waste management�Public transportation�Telecommunications�Cable providers�Energy distribution (electricity, gas)

, Hyundai’s low voltage motor control center, features a

withdrawable unit, multi-tier construction, factory assembly

and is suitable for L/V distribution systems of up to 1000V AC.

■ is designed and manufactured in accordance with our quality assuranceprogram which is based on ISO 9001, ISO 14001 and SHSAS 18001accreditations.

�Personnel and equipment safety�Easy installation�Easy, fast operation and maintenance�Future extensions

Presentation

Use

is a modular motor control and L/V distribution systemfeaturing a fully withdrawable unit.

Buildings, machinery and processes

uses L/V motor control centers of up to 1000V forprocess control and electrical power distribution.

can be applied to all arrangements and all types oflayouts and location configurations.

meets the most stringent requirements in term of:

Page 3: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

HiMCC offers

simple engineering,

quick installation and safety.

We build a better future!

Contents

Technical Data

Withdrawable Unit Design

Control & Power Cable Connections

Interlocking Device

Unit Position

Panel Arrangement and Dimensions

Selection of Standard Units

Test Reports

Low Voltage Switchgear

4

6

7

8

9

10

11

13

14

Cost savings

Easy to operate

Advanced safety features

Arc resistance

Major Features

◀2 3▶

Page 4: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

Technical Data

Low Voltage Switchgear & Control Center

Rated insulation voltage

Rated operation voltage

Rated frequency

Bus barcurrents(3/4 poles)

Main

Vertical

Dimensions

Surfaceprotection

Degree of protectionMechanicalcharacteristics

up to 1000V

up to 690V

Rated current

Rated short time withstand current

Rated peak withstand current

Rated current

Rated short time withstand current

Rated peak withstand current

Height

Width

Depth

Frame

Enclosure

Internal subdivision

50/60Hz

up to 5000A

up to 100kA/1sec

up to 220kA

2300mm

1000mm

650mm (front only)/1200mm (back to back)

Normal IP 4X up to IP 54

Galvanized

Paint RAL-7032 (Standard)

Galvanized

Form-4b

1000A

65kA/1sec

143kA

1200A

80kA/1sec

176kA

Form degree

Applicable Standards

complies with the following standards:

� IEC 60947-1: General rules

� IEC 60947-2: Circuit breakers

� IEC 60947-3: Switches

� IEC 60947-4: Contactors

� IEC 60439-1: Low voltage switchgear

controlgear assembly

� IEC 61641: Internal arc fault

� IEC 60529: Degree of protection

Page 5: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

In accordance with IEC 60439-1 anddepending on customer requirements, the functioncompartments can be subdivided as per thefollowing diagrams.

Forms of Internal Separation

Forms of internal separation according to IEC 60439-1

Form 1 Form 2a Form 3a Form 4a

Form 2b Form 3b Form 4b

Functional unitTerminal for external conductors

1 Main busbar2 Vertical busbar3 Incoming circuit 4 Outgoing circuit

◀4 5▶

Page 6: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

Low Voltage Switchgear & Control Center

■Simple-to-operate withdrawable units preventoperator errors. Withdrawable units offer a large amount of space for individual accessories.

The full withdrawable unit of size 1 has a height of onemodule spacing (200 mm) and can be replaced by 2 units ofsize 1/2 (half module).

The withdrawable units of size 2 and 3 have heights of 2 and 3 module spacing, respectively.

The maximum complement of a cubicle is, for example, 10 full-size withdrawable units of size 1 or 20 miniaturewithdrawable units of size 1/2.

Withdrawable Units Size

Withdrawable Unit Design

A distinction is made between the half module and full withdrawable units (sizes 1, 2, and 3),as shown in following figures.

High density packing withup to 20 feeders per cubicle.

3 Module

Front View (1/2 Module) 1 Module

2 Module

Page 7: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

◀6 7▶

Control & Power Cable Connections

Type

1/2

Module

1M-3M

100AF

225AF

400AF

Module Capacity Control part Power part

1. Manufacturer’s cable

1) Cable- Type: XHHW- Size: 1.5SQ- Color: Gray- Vinyl tube

2) Terminal block

2. User’s cable- Size: up to 2.5SQ

1. Manufacturer’s cable - 25SQ (SCP/Blck)- Color U � Red

V � WhiteW � Blue

2. User’s cable- up to 38SQ- 1 core/phase

1. User’s cable- up to 95SQ- 2 core/phase

1. User’s cable- up to 185SQ- 2 core/phase

※The terminal block is the manufacturer’s standard.If specifications differ from the standard, advance notice must be given.

Page 8: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

Low Voltage Switchgear & Control Center

Interlocking Device

When the power is on, the operator is protected by preventing the unit from whithdrawal and insertion.

Locking bar is locked Locking bar is released

When the MCCB is on, the positon handle is locked by alocking bar, so the unit cannot be withdrawn and inserted.

When the MCCB is off, the positon handle is released by alocking bar, so the unit can be withdrawn and inserted.

MCCB “ON” MCCB “OFF”

Service position Service position

Locking Unlocking

MCCB MCCB

Interlocking device assembly Interlocking device assembly

MCCB handle assembly Position handle assembly MCCB handle assembly Position handle assembly

Page 9: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

◀8 9▶

Unit Position

Designation ofposition

Connected

Position

Test

Position

Disconnected

Position

Withdrawable principle Description of function

MCCB

Power circuit primary plug

Power circuit secondary plug

Control circuit

The unit cannot be withdrawn in this position(the unit is mechanically interlocked)

MCCB

Power circuit primary plug

Power circuit secondary plug

Control circuit

The unit can be withdrawn by 30 mm in thisposition

MCCB

Power circuit primary plug

Power circuit secondary plug

Control circuit

The unit can be completely drawn out from thecubicle

On

Closed

Closed

Closed

Off

Open

Open

Closed

Off

Open

Open

Open

Page 10: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

Low Voltage Switchgear & Control Center

Front Only Type Back to Back Type

withdrawable 1/2 module & 1 module units.

Space for incoming MCCB

※ For incoming feeders above 600AF MCCB, please contact us.

(unit: mm)

Panel Arrangement and Dimensions

Incoming MCCB Space for unit (height) Unit type

Below 100AF 1 Module (200mm) Drawout type

Below 225AF 1 Module (200mm) Drawout type

Below 400AF 1.5 Module (300mm) Drawout type

Below 400AF with CT 2.0 Module (400mm) Drawout type

Below 600AF 4 Module (800mm) Fixed type

Below 600AF with CT 4 Module (800mm) Fixed type

Page 11: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

◀10 11▶

Power (kW)

0.1

0.2

0.37

0.4

0.43

0.75

0.9

1.5

2.2

2.5

3.7

5

5.5

7.5

9

11

15

18.5

22

30

37

45

55

75

90

95

110

125

25 -100

42

85

100

42

85

100

42

85

100

42

85

100

42

85

100

42

85

100

42

85

100

42

85

100 42

85

100

42

85

100 42

85

100

0.25 0.23

0.5 0.43

0.93 0.85

1.01 0.91

1.08 0.98

1.89 1.71

2.26 2.05

3.77 3.42

5.26 4.82

5.76 5.28

8.52 11.1

11.1 12.21

12.21 16.35

16.35 19.27

19.27 23.55

23.55 31.74

31.74 31.74

38.23 35.02

45.47 41.64

61.28 56.1

74.72 68.45

93.12 83.25

112.54 101.75

148.96 136.39

178.75 163.67

188.68 172.76

218.47 200.04

248.26 227.32

GV2-RS 03 GV2-RS 02

GV2-RS 04 GV2-RS 04

GV2-RS 05

GV2-RS 06

GV2-RS 07GV2-RS 06

GV2-RS 07

GV2-RS 08 GV2-RS 08

GV2-RS 10 GV2-RS 10

GV2-RS 14 GV2-RS 14

GV2-RS 16GV2-RS 16

GV2-RS 20

GV2-RS 17 GV2-RS 21

GV2-RS 18 GV2-RS 22

GV2-RS 23 GV2-RS 23

HiBH-103HiBL-103NT

HiBL-103NT

HiBX-103NT HiBX-103NT

HiBH-103

HiBL-103NTHiBL-103NT

HiBX-103NT HiBX-103NT

HiBH-103

HiBL-103NTHiBL-103NT

HiBX-103NT HiBX-103NT

HiBH-203

HiBL-203NTHiBL-203NT

HiBX-203NT HiBX-203NT

HiBH-203

HiBL-203NTHiBL-203NT

HiBX-203NT HiBX-203NT

HiBH-203

HiBL-203NTHiBL-203NT

HiBX-203NT HiBX-203NT

HiBH-203

HiBL-203NTHiBL-203NT

HiBX-203NT HiBX-203NT

HiBS-403NE HiBS-403NE

HiBL-403NE HiBL-403NE

HiBX-403NE HiBX-403NE

HiBS-403NE HiBS-403NE

HiBL-403NE HiBL-403NE

HiBX-403NE HiBX-403NE

HiBS-403NE HiBS-403NE

HiBL-403NE HiBL-403NE

HiBX-403NE HiBX-403NE

HiBS-403NE HiBS-403NE

HiBL-403NE HiBL-403NE

HiBX-403NE HiBX-403NE

HiMC 12

HiMC 18

HiMC 22

HiMC 32

HiMC 50

HiMC 50

HiMC 65

HiMC 80

HiMC 90

HiMC 130

HiMC 150

HiMC 180

HiMC 220

HiMC 220

HiMC 260

HiMC 300

HiTH 50K

HiTH 90K

HiTH 90K

HiTH 90K

HiTH 130K

HiTH 220K

HiTH 220K

HiTH 220K

HiTH 220K

HiTH 300K

HiTH 300K

16

25

35

50

50

35×2

35×2

35×2

35×2

50×2

HiMC 9

6_

1/2M

1M

2M

3M

10

Full load current (A)

380V 415V

MCCB type

380V 415V

Breakingcapacity

(kA)

Magneticcontactor

Thermalrelay

Cable(mm2)

Unit size

GV2-RS 05

※ For power ratings over 132kW, Y-△ and reactor starters, please contact us.

380V / 415V Withdrawable Unit Design - DIRECT

Selection of Standard Units

Page 12: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

Low Voltage Switchgear & Control Center

Selection of Standard Units

440V / 460V Withdrawable Unit Design - DIRECT

Power (kW)Full load current (A)

440V 460V

MCCB type

440V 460V

Breakingcapacity

(kA)

Magneticcontactor

Thermalrelay

Cable(mm2)

Unit size

0.10.20.370.40.430.750.91.52.22.5

3.7

5

5.5

7.5

9

11

15

18.5

22

30

37

45

55

75

90

95

110

125

25 -100

42 85 100 42 85 100 42 85 100 42 85 100 42 85 100 42 85 100 42 85100 42 85 100 42 85 100 42 85 100 42 85 100 42 85100428510042 85100428510042851004285 10042 85 100

HiMC 9

HiMC 12

HiMC 18

HiMC 22

HiMC 32

HiMC 50

HiMC 65

HiMC 80

HiMC 90

HiMC 130

HiMC 150

HiMC 180

HiMC 220

HiMC 220

HiMC 260

HiMC 300

-

-(HiTH 22K)

HiTH 22K

HiTH 40K

HiTH 50K

HiTH 90K

HiTH 90K

HiTH 130K

HiTH 220K

HiTH 220K

HiTH 300K

5.5

5.5

8

14

22

38

50

50

38×2

38×2

38×2

38×2

50×2

GV2-RS 02 GV2-RS 02GV2-RS 04 GV2-RS 02GV2-RS 05GV2-RS 05 GV2-RS 05GV2-RS 05GV2-RS 07 GV2-RS 06GV2-RS 07 GV2-RS 07GV2-RS 08 GV2-RS 08GV2-RS 10 GV2-RS 10GV2-RS 10

GV2-RS 14GV2-RS 14 HiBL-103NT

HiBX-103NTGV2-RS 14

GV2-RS 14 HiBL-103NTHiBX-103NT

GV2-RS 16 GV2-RS 16HiBL-103NT HiBL-103NTHiBX-103NT HiBX-103NT

HiBL-103NTGV2-RS 16HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT

HiBL-203NT HiBL-203NT

HiBX-203NT HiBX-203NT

HiBL-203NT HiBL-203NT

HiBX-203NT HiBX-203NT

HiBL-203NT HiBL-203NT

HiBX-203NT HiBX-203NTHiBS-403NE HiBS-403NEHiBL-403NE HiBL-403NEHiBX-403NE HiBX-403NEHiBS-403NE HiBS-403NEHiBL-403NE HiBL-403NEHiBX-403NE HiBX-403NEHiBS-403NE HiBS-403NEHiBL-403NE HiBL-403NEHiBX-403NE HiBX-403NEHiBS-403NE HiBS-403NEHiBL-403NE HiBL-403NEHiBX-403NE HiBX-403NE

0.22 0.210.43 0.420.8 0.770.87 0.830.93 0.891.63 1.561.95 1.873.26 3.114.54 4.344.97 4.75

7.36 7.04

9.58 9.17

10.54 10.08

14.12 13.5

16.64 15.92

20.34 19.45

27.41 26.22

33.02 31.58

39.27 37.56

52.93 50.63

64.53 61.72

80.42 76.92

97.2 92.97

128.64 123.05

154.37 147.66

162.95 155.86

188.68 180.47

214.41 205.08

1/2

1/2

1

2

3

※ For power ratings over 132kW, Y-△ and reactor starters, please contact us.

Page 13: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

※ For power ratings over 132kW, Y-△ and reactor starters, please contact us.

◀12 13▶

380V / 415V / 440V / 460V Withdrawable Unit Design - MCCB ONLYBreakingcapacity

(kA)

Power(kW)

MCCB 3P type

380V 415V 440V 460V

Magneticcontactor

Thermalrelay

Cable(mm2)

Unit size

25 - 100

42

85

100

42

85

100

42

85

100

MCCB100AF

MCCB225AF

MCCB400AF

1/2M

1M

1.5M

5.5

22

38×2

50×2

_ _

GV2-RS **

HiBH-103

HiBL-103NTHiBL-103NT HiBL-103NT HiBL-103NT

HiBX-103NT HiBX-103NT HiBX-103NT HiBX-103NT

HiBH-203

HiBL-203NTHiBL-203NT HiBL-203NT HiBL-203NT

HiBX-203NT HiBX-203NT HiBX-203NT HiBX-203NT

HiBS-403NE HiBS-403NE HiBS-403NE HiBS-403NE

HiBL-403NE HiBL-403NE HiBL-403NE HiBL-403NE

HiBX-403NE HiBX-403NE HiBX-403NE HiBX-403NE

Test Reports

Page 14: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

Low Voltage Switchgear & Control Center

Low Voltage Switchgear

is a sheet metal system enclosure suitable for

low voltage switchgear installations in commercial buildings,

industrial plants and electric power generating stations.

The low voltage switchgear equipment has been evaluated in

a comprehensive analysis and tested for maintainability and

life expectancy.

Hyundai’s in-depth knowledge of protection technology has

led to the development of a comprehensive range of

distribution equipment that is compact and economical.

Overview

The low voltage switchgear system has proven its worth throughout the world.

It is a safe investment for the future due to its continuous development. The high

flexibility of the L/V SWGR system can be equipped as required with standardized

components and can be perfectly adapted to any application.

The various application both in electrical and mechanical design permits the optimal

selection of structural design, interior arrangement, and degree of protection, according

to the operating and environmental conditions. The design and materials used for the

L/V SWGR system largely prevent the occurrence of electric arc or allows arc quenching

within a short time. Type test certificates are available. In this test, we proved the

accidental arcs were limited to the places of occurrence.

The L/V SWGR system offers the user many alternative solutions and notable

advantages that convention of installations cannot provide.

Features

Page 15: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

◀14 15▶

Technical Data

Electricaldata

Rated

voltage

Rated

current

Dimensions

Surfaceprotection

Degree of protectionMechanicalcharacteristics

Rated insulation voltage

Rated operating voltage

Rated current

Rated short time withstand current

Rated peak withstand current

Rated frequency

Height

Width

Depth

Frame

Enclosure

Internal subdivision

50/60Hz

up to 1000V

up to 690V

up to 5000A

up to 1000kA/1sec

up to 220kA

2300mm

600/700/800/1000/1200mm

650/800/1200/1500mm

Normal IP 4X, up to IP 54

Galvanized

Paint RAL-7032 (standard)

Galvanized

Form-4bForm degree

Construction

� The switchger is comprised of indoor units, offering

completely isolated breaker and instrument compartments

� The removable circuit breaker power element is equipped

with disconnecting contacts and interlocking contacts for

withdrawal

� A lifting device for the power circuit breakers can be

provided

Page 16: Applicationsctae.co.th/files/Products/HYUNDAI HEAVY INDUSTRY P… ·  · 2013-09-27In accordance with IEC 60439-1 and ... following diagrams. Forms of Internal Separation ... Form

HH

IS-W

C-S

E-B

12-03, ’08. 07 Designed by A

DP

AR

K

www.hyundai-elec.com

Head Office 1 Jeonha-dong, Dong-gu, Ulsan, Korea Tel. 82-52-202-8101~8 Fax 82-52-202-8100

Seoul 140-2, Gye-dong, Jongno-gu, Seoul, Korea (Sales & Marketing) Tel. 82-2-746-7579, 8463 Fax 82-2-746-7648 Domestic Sales: Tel. 82-2-746-7610, 7622 Fax 82-2-746-7607

Orlando 3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A.Tel. 1-407-249-7350 Fax 1-407-275-4940

New Jersey 300 Sylvan Avenue Englewood Cliffs, NJ 07632, U.S.A.Tel. 1-201-816-0286, 4080 Fax 1-201-816-4083

London 2nd Floor, The Triangle, 5-17 Hammersmith Grove London, W6 0LG, UKTel. 44-20-8741-0501 Fax 44-20-8741-5620

Tokyo 8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-gu, Tokyo, 100-0006, JapanTel. 81-3-3212-2076, 3215-7159 Fax 81-3-3211-2093

Osaka I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, Japan, 542-0081Tel. 81-6-6261-5766, 5767 Fax 81-6-6261-5818

Dubai Room 6206, Al Bustan Centre Al Qusais P.O.Box 252458 Dubai, U.A.E.Tel. 971-4-263-9071 Fax 971-4-263-9072

Sofia 1271, Sofia 41, Rojen Blvd, BulgariaTel. 359-2-803-3200, 3220 Fax 359-2-803-3203

Yangzhong Lianzhong Avenue, Xinba Scientific and Technologic Zone, Yangzhong City, Jiangsu 212212, ChinaTel. 86-511-842-0666, 0212 Fax 86-511-842-0668