Page 1: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

HELWAN LAB.

PREPARATION Yasser Assran

Gabriella Pugliese

1

Page 2: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

What we have in Helwan HV Power system SY 2527 Universal Multichannel Power Supply

System with HV modules and High Voltage Power Supply (0-3 KV)

(ORTEC 456) for scintillator.

LV system --> SY 2527 Universal Multichannel Power Supply System with LV modules.

GAS system ..> Gas Mixer, Freon bottle and Ar-CO2 bottle. We need to switch to RPC standard mixture.

Electronic for trigger -->

QUAD Discriminator (Model 621AL)

CMS RPC Receiver.

Discriminator (Model 620AL)

Coincidence Unit (Model 465)

QUAD SCALER AND PRESET COUNTER TIMER (MOD.N1145)

Linear FAN-IN/FAN-OUT (Model 428F)

Linear FAN-OUT (Model 128L)

Four Scintillators (50x50 Cm)

GWINSTEK GDS-2204 Digital storage Oscilloscope (200 MHZ 1G Sa/a). 2

Page 3: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

3

Page 5: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

What we miss ECL-NIM-ECL module

linear Fan-out

Gas Mixture

Coincidence unit

Scalar

Dual Timer.

5

Page 6: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

What we did

Gap tests.

Gas leak test.

Spacer Test.

HV Test.

6

Page 7: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

7

Page 8: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

Results at 904 (scintillators HV scan)

0

1000

2000

3000

4000

5000

6000

7000

1500 1550 1600 1650 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2200

Co

un

t / 1

00

Se

c

HV (v)

HV Scan

1

2

8

Page 9: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

HV scan for RPC parts

0

200

400

600

800

1000

1200

1400

1600

6000 6500 7000 7500 8000 8500 9000 9500 10000 10500

Co

un

ts H

z

Hv

B21

B22

C11

C12

C21

C22

9

Page 10: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

chamber performance test with

cosmic:

Scintillator1 DISCR.

SCALER

Scintillator2 DISCR.

RECIEVERRPC

COINCIDENC

E

FAN

OUT

COINCIDENC

E

SCALER

10

Page 11: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

Calibration of scintillator

11

Page 12: Helwan Lab. Preparation€¦ · ECL-NIM-ECL module ... B21 B22 C11 C12 C21 C22 9 chamber performance test with cosmic: Sci nt i l l at or 1 DISCR. SCALER Sci nt i l l at or 2 DISCR

Our plan Transfer the hardware to Helwan.

Complete the installation of the all hardware needed.

Complete the set-up of the telescope (hardware and software).

run the DAQ system (the same used in GIF) and applied the necessary modifications.

test the RPC performance with cosmic muon (spare chambers from CMS Endcap have been requested to CMS- RPC collaboration).

12