Page 1: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

HeradesignTechnical Manual

Page 2: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness
Page 3: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

3

1. Products and CharacteristicsProduct line Trend

Decorative 1-layer panels ........................................................................................................................ 5Heradesign® superfineHeradesign® fineHeradesign® fine/A2Heradesign® microHeradesign® plano

Edges, Colours, Accessories .................................................................................................................. 35

modo Ceiling System .............................................................................................................................. 55

Decorative 2-layer panels ........................................................................................................................ 59Heradesign® micro plus

Product line Executive

Decorative 3-layer panels ........................................................................................................................ 65Heradesign® styleHeradesign® deluxe

2. Ceiling ConstructionsInstallation with Top Hat Sections on CD Sections .................................................................................... 80Insertion Installation in Visible T-Sections .................................................................................................. 83Suspended Ceilings – Concealed T-Sections/Panels can be disassembled .............................................. 90Suspended Ceilings – Concealed T-Sections/Panels can not be disassembled ........................................ 93Suspended Ceilings – Visible Omega Sections ........................................................................................ 96Installation with Heradesign retaining claws .............................................................................................. 99Fastening onto Wood Laths .................................................................................................................... 103Fastening onto CD-Metal Sections .......................................................................................................... 110Direct mounting on concrete ceilings with Heradesign Concrete Decorative Screw .................................... 116Facing panel .......................................................................................................................................... 118

3. Application and Handling ................................................................................... 121

4. CertificatesBuilding biology certificate ....................................................................................................................... 134EC Certificate ......................................................................................................................................... 138Sound absorption values ........................................................................................................................ 140Fire protection Building Component Classification .................................................................................... 142Safety against ball throwing ..................................................................................................................... 143Building Material Classification ................................................................................................................. 144Other test data ....................................................................................................................................... 145

Table of Contents

Page 4: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

4

Page 5: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

5

1. Products and CharacteristicsProduct line Trend

Decorative 1-layer panels

Page 6: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

6

Heradesign® superfine

Magnesite- bound wood wool decorative panels of fine wood fibre structure. Fibre width approx 1 mm.

Product Type:WW - EN 13168 - L3-W2-T2-S3-P2-CS(10)200-Cl3

Advantages:regulation of climate in the roomdiffusion open structureall colours possiblerecognised for organic building design

Application: Offices, department stores, dwelling houses, schools, kindergartens, public offices, events halls, gymnasiums, sports and multi purpose halls.

Formats:600 x 600, 1200 x 600, 625 x 625, 1250 x 625 mm (max. lengths: 2500 mm, max. width: 625 mm)

ColoursWe recommend white ( similar RAL 9010) or natural colour tone 13 ( beige)

Note:Deviations in colour tone against colour chart and colour feeling are possible due to the rough fibre rep. panel surface .

Production tolerances to nominal dimension: L3, W2, T2: ± 1 mm, for lengths > 1250mm L3 = ± 2 mm.Foil ( thickness < 15 μm) recommended as drip protection for mineral wool layers Maximum change of dimensions at standard operating environment 23° C/50 % rel. air humidity: 1 ‰

Limit of use:Max. span 625mmSuitable for use in environments having a continuous rel. air humidity of up to 90 %For conditions above 80 % rel. air humidity constructional-physics advise is necessary.Do not glue panels against ceiling and walls!

Delivery programme

Thickness [mm] 15 25 35 Weight [kg/m²] 7,3 10,8 15,0 m2/packaging unit-standard formats::600 x 600. 1200 x 600 mm [m²] 80,64 50,40 36,00625 x 625. 1250 x 625 mm [m²] 43,75 27,34 19,53

Delivery from: palletes, with protective carton. Supplied only in complete packaging units! Special lengths and edge finishings on request.

Page 7: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

7

Technical specifications

Characteristic Symbol Description/Data Unit Standard

Fire behavior --- B-s1, d0 [---] EN 13501-1Thickness d 15 25 35 [mm] EN 13168

Thermal conductivity D 0,080 0,080 0,080 [W/mK] EN 12667Thermal resistance RD 0,20 0,30 0,45 [m2K/W] EN 13168Flexural strength *) b >2000 >1800 >1600 [kPa] EN 12089 Diffusion resistance factor μ 5 5 5 [---] EN 12086

*) According EN 12089, producedure A

Sound absorption coefficients p

Frequency (Hz) 125 250 500 1000 2000 4000 wAbsorber classes

Heradesign® super fine, 25 mmWithout gap 0,05 0,15 0,25 0,50 0,80 0,70 0,35(H) D3 cm gap 0,10 0,20 0,45 0,70 0,55 0,75 0,45(MH) D27,5 cm gap 0,30 0,50 0,40 0,50 0,65 0,75 0,50(H) D3 cm gap / 3 cm Heralan DP-5: 0,15 0,50 0,95 0,90 0,80 0,90 0,80 B27,5 cm gap /4 cm Heralan DP-5: 0,70 0,90 0,90 0,90 0,80 0,95 0,90 A3 cm gap / 3 cm Heraflax-SAP: 0,20 0,50 0,90 0,90 0,70 0,90 0,75(H) C27,5 cm gap / 4 cm Heraflax-SAP 0,65 0,80 0,75 0,75 0,80 0,90 0,80 B

Figures for other designs on request

The installation of Heradesign panels is part of the interior works and have to be carried out under controlled humidity and temperature conditions. Any building activities which gives rise to dust and humidity have to be completed before starting installation of panels. Store panels flat and protect against humidity and dirt. Stack a maximum of two pallets, height maximum 250 cm. The packaging provided does not provide protection from rain. Please pay attention to the application, installation and storage guidlines of Heradesign panels.

For further information, please contact:

Heradesign Ceilings Division A business unit of Knauf Insulation GmbH A – 9702 Ferndorf 29 Phone: +43/4245-2001 3332 Fax: +43/4245-2001 3056 [email protected]

The present product data sheet corresponds with the current state of development of our products and will cease to be valid on publication of a new edition. Please check that you are using the latest edition of this information. The suitability of the product is not binding for special individual cases. Warranty and liability shall be in accordance with our Standard Terms of Business- PGDB_Heradesignk® superfine. 01.04.2008 (replace Version 20.03.2006 )

Page 8: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

8

Edges: 1-layer Decorative

Heradesign® superfine

Please note:***) Heradesign® plano: Panel thickness only 25 mm, max. width 600 mm; for edge VK-09: bevel only 3 mm

Heradesign® fine/A2: Panel thickness only 25 mm, max. width 600 mm

Attention:*) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness of 15 mm and edge SK-04.**) Custom formats only on request – length max. 1800 mm (contact technical customer service)

Abb

revi

atio

n

Des

ign

for

mm

Her

ades

ign®

supe

rfine

Rec

omm

. sec

tio n

wid

th

Com

men

ts

Grid

dim

ensi

ons

2) 3

)

Pan

el d

imen

sion

s

15 25 35 mm mm

Recommended standard edge designs and grid dimensions

GKstraight edge on all sides for screw mounting

13

600/6001200/600

600/6001200/600

AK-00bevelled on long sides (5 mm bevel) for screw mounting 3

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

AK-01bevelled on all sides (5 mm bevel) for screw mounting

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

SK-04*)straight edges only for visible T-section undercut as of 35 mm thickness 24 1

2600/600, 625/6251200/600, 1250/625

594/594, 619/6191194/594, 1244/619

SK-08straight on the long side, front side with bevelled edges for Omega section (5mm bevel)

20 2620, 645 595/600, 620/625

595/1200, 620/1250

Special Designs

AK-02shiplap on all sides for screw mounting 3 600/600, 1200/600

625/625, 1250/625600/600, 1200/600625/625, 1250/625

AK-03shiplap on all sides with 5 mm bevel for screw mounting

600/600, 1200/600625/625, 1250/625

600/600, 1200/600625/625, 1250/625

SK-05shiplap on all sides for visible T-section

24 2 600/600, 1200/600625/625, 1250/625

594/594, 619/6191194/594, 1244/619

SK-06shiplap on all sides with 5 mm bevel for T-section 24 2 600/600, 1200/600

625/625, 1250/625594/594, 619/619

1194/594, 1244/619

VK-09**)concealed T-section for push-in mounting – panels grooved and bevelled on all sides (5 mm bevel)

35 3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

VK-10**)concealed T-section – panels can be disassembled – panels grooved and bevelled on all sides.

35 23

600/6001200/600

615/600615/1200

VK-12shiplap all round on alternating sides with 5 mm bevel. 2

31190/5901240/615

1200/6001250/625

System edges

SY-01straight edges on all sides, grooved on the long sides, undercut on the cross sides for modo ceiling system

600/6001200/600

596/6001200/596

SY-02lgrooved on the long sides, bevelled on all sides for Heradesign retaining claw

3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

1 The straight edge is not an exposed edge. Straight edge only produced at the express request of the customer.2 The billing dimensions or alternatively the ordering dimensions are always the grid dimensions.3 Installation pattern in cross joints requires very careful installation, because four visible panel edges have to meet at one point.

Page 9: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

9

Construction Description * Classification Certificate

Heradesign® superfine, d = 25 mmin T-track system suspended as insertion installation, with Heralan DP-5 lining d 2 x 50 mm

EI 30(a<—b)

Classification report No. MA39-VFA 2004 -1945.02

(A)

Heradesign® superfine, d = 25 mm screwed to CD sections 2 x 60/27, with Heralan DP-5 lining d 2 x 30 mm

EI 30(a<—b)

Classification report No. MA39-VFA

2006- 0699.01 (A)

Fire Protection – Building Component Classification for 1-layer Decorative PanelsHeradesign® superfine

* Attention: The classification only applies to the certified design. A reduction of the gross density of the mineral wool or the thickness of the lining or alternatively the panel thickness is not permitted. Only F 30 or F 60 certified hanging systems may be used as a substructure.

Page 10: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

10

Panel type Panel

thickness

(mm)

Spacingto ceiling(mm) 1)

Backfilling(mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2)entire range

Test item Certificates Degree of sound absorption pFrequencies (HZ)

Without backfilling15 30 0 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.05 0.15 0.35 0.70 0.65 0.70 0.45 0.40 (MH) D15 283 0 A/TGM Wien 10656/AB 18.06.03 p 0.10 0.35 0.55 0.45 0.50 0.60 0.75 0.55 0.50 (LH) D25 0 0 A/TGM Wien 10575/WS 23.09.02 p 0.05 0.05 0.15 0.25 0.50 0.80 0.70 0.45 0.35 (H) D

Heradesign® 25 30 0 A/TGM Wien 10575/WS 23.09.02 p 0.05 0.10 0.20 0.45 0.70 0.55 0.75 0.50 0.45 (MH) D superfine 25 275 0 A/TGM Wien 10575/WS 23.09.02 p 0.30 0.50 0.40 0.50 0.65 0.75 0.55 0.50 (H) D

35 30 0 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.10 0.25 0.55 0.80 0.65 0.85 0.55 0.55 (MH) D35 265 0 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.40 0.55 0.45 0.60 0.75 0.90 0.60 0.55 (H) D

With mineral wool15 30 30 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.10 0.45 0.90 0.95 0.80 0.85 0.75 0.75 C15 283 40 A/TGM Wien 10656/AB 18.06.03 p 0.25 0.65 0.85 0.90 0.90 0.85 0.85 0.85 0.90 A

Heradesign® 25 30 30 A/TGM Wien 10575/WS 23.09.02 p 0.05 0.15 0.50 0.95 0.90 0.80 0.90 0.80 0.80 B superfine 25 275 40 A/TGM Wien 10575/WS 23.09.02 p 0.70 0.90 0.90 0.90 0.80 0.95 0.90 0.90 A

35 30 30 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.15 0.60 0.95 0.90 0.85 0.95 0.85 0.85 B35 265 40 A/TGM Wien 10656/AB 18.06.03 p 0.20 0.70 0.90 0.90 0.90 0.90 1.00 0.90 0.90 A

With flax wool Heradesign® 25 30 30 A/TGM Wien 10575/WS 23.09.02 p 0.20 0.50 0.90 0.90 0.70 0.90 0.75 0.75 (H) C superfine 25 275 40 A/TGM Wien 10575/WS 23.09.02 p 0.65 0.80 0.75 0.75 0.80 0.90 0.80 0.80 B

Absorber-class

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient according to ASTM – C423

Sound Absorption Values

Heradesign® superfine

Page 11: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

11

Design that is safe against ball throwing

according to DIN 18 032/Part 3

Heradesign® superfine

Test item Construction Test Institute CertificatesNo. / Date

Results

Ceiling

Heradesign® superfine,35 mm

Screw mounted under metal profiled sectionsCD sections 27 x 60 x 0.7 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3 x dry-wall screws/support

D Research and materials testing institute, Baden-Württemberg, FMPA Stuttgart

901 3895-3/Sc/Kf

20.08.2007

“Safe against ball throwing” as per DIN 18032/ Part 3or Class 1A as perEN 13,964 Appendix D

Heradesign® superfine,35mm

Screw mounting underwood lath 30 x 50 mmCentre distance 625mmFastening:3 x dry-wall screws/support

D Research and materials testing institute, Baden-Württemberg, FMPA Stuttgart

901 3895-2/Sc/Kf

20.08.2007

“Safe against ball throwing” as per DIN 18032/ Part 3or Class 1A as perEN 13,964 Appendix D

Wall

Heradesign® superfine,35 mm

Screw installation on metal sectionsCD sections 27 x 60 x 0.7 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3 x dry-wall screws/support

D Research and materials testing institute, Baden-Württemberg, FMPA Stuttgart

9013895-4/Sc/Kf

20.08.2007

“Safe against ball throwing” as per DIN 18032/ Part 3

Page 12: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

12

Heradesign ® fine

Magnesite - bound wood wool decorative panels of fine wood fibre structure. Fibre width approx. 2 mm

Product Type:WW - EN 13168 - L3-W2-T2-S3-P2-CS(10)200-Cl3

Advantages:regulation of climate in the room

diffusion open structure all colours possiblerecognised for organic building design

Application:Offices, department stores, dwelling houses, schools, kindergartens, public offices, events halls, gymnasiums, sports and multi purpose halls.

Formats:600 x 600, 1200 x 600, 625 x 625, 1250 x 625 mm (max. lengths 2500 mm, max.

width 625 mm)

ColoursWe recommend white ( similar RAL 9010) or natural colour tone 13 ( beige)

Note:Deviations in colour tone against colour chart and colour feeling are possible due to the rough fibre resp. panel surface. Production tolerance, to nominal dimension: L3, W2, T2= ± 1 mm, for lengths > 1250 mm L3 = ± 2 mm. Foil ( thickness < 15μm) recommended as drip protection for mineral wool layers Maximum change of dimensions at standard operating environment 23 ° C/50 % rel. air humidity : ± 1 ‰.

Limit of use:Max. span 625 mm Suitable for use in environments having a continuous rel. air humidity of up to 90 %. For conditions above 80 % rel. air humidity constructional-physics advise is necessary. Do not glue panels against ceiling and walls!

Delivery programme

Thickness [mm] 15 25 35 Weight [kg/m²] 8,0 12,0 16,0 m²/ packaging unit-standard formats:600 x 600. 1200 x 600 mm [m²] 80,64 50,40 36,00625 x 625. 1250 x 625 mm [m²] 43,75 27,34 19,53

Delivery form: palleted, with protective carton. Supplied only in complete packaging units! Special length, and edge finishing, on request.

Page 13: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

13

Technical specifications

Characteristic Symbol Description / Data Unit Standard

Fire behavior --- B-s1, d0 [---] EN 13501-1Thickness d 15 25 35 [mm] EN 13168

Thermal conductivity D 0,080 0,080 0,080 [W/mK] EN 12667Thermal resistance RD 0,20 0,30 0,45 [m2K/W] EN 13168Flexural strength *) b >2000 >1800 >1600 [kPa] EN 12089 Diffusion resistance factor μ 5 5 5 [---] EN 12086

*) According EN 12089, producedure A

Sound absorption coefficients p

Frequency (Hz) 125 250 500 1000 2000 4000 wAbsorber classes

Heradesign® fine, 25 mmWithout gap 0,10 0,15 0,25 0,65 0,75 0,70 0,35(MH) D

3 cm gap 0,10 0,20 0,60 0,75 0,60 0,80 0,50(MH) D

30 cm gap 0,55 0,55 0,35 0,45 0,60 0,80 0,45(LH) D

3 cm gap/ 3 cmHeralan DP-5 0,20 0,60 1,00 0,75 0,70 0,85 0,75(M) B

27,5 cm gap / 4 cm Heralan DP-5 0,85 0,80 0,80 0,75 0,80 0,90 0,80 B

4 cm gap / 4 cm Heraflax-SAP 0,25 0,75 0,95 0,70 0,65 0,85 0,70(LMH)

C

gap: 27,5 cm / 4 cm Heraflax-SAP 0,75 0,85 0,65 0,70 0,70 0,85 0,70(LH) C

Figures for other designs on request.

The installation of Heradesign panels is part of the interior works and have to be carried out under controlled humidity and temperature conditions. Any building activities which gives rise to dust and humidity have to be completed before starting installation of panels. Store panels flat and protect against humidity and dirt. Stack a maximum of two pallets, height maximum 250 cm. The packaging provided does not provide protection from rain. Please pay attention to the application, installation and storage guidelines of Heradesign panels.

For further information, please contact:

Heradesign Ceilings Division A business unit of Knauf Insulation GmbH A – 9702 Ferndorf 29 Phone: +43/4245-2001 3332 Fax: +43/4245-2001 3056 [email protected]

The present product data sheet corresponds with the current state of development of our products and will cease to be valid on publication of a new edition. Please check that you are using the latest edition of this information. The suitability of the product is not binding for special individual cases. Warranty and liability shall be in accordance with our Standard Terms of Business.

PGDB_Heradesign® fine engl 01.04.2007(replace Version 27.06.2005)

Page 14: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

14

Abb

revi

atio

n

Des

ign

for

mm

Her

ades

ign®

fine

Rec

omm

. sec

tio n

wid

th

Com

men

ts

Grid

dim

ensi

ons

2) 3

)

Pan

el d

imen

sion

s

15 25 35 mm mm

Recommended standard edge designs and grid dimensions

GKstraight edge on all sides for screw mounting

13

600/6001200/600

600/6001200/600

AK-00bevelled on long sides (5 mm bevel) for screw mounting 3

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

AK-01bevelled on all sides (5 mm bevel) for screw mounting

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

SK-04*)straight edges only for visible T-section undercut as of 35 mm thickness 24 1

2600/600, 625/6251200/600, 1250/625

594/594, 619/6191194/594, 1244/619

SK-08straight on the long side, front side with bevelled edges for Omega section (5mm bevel)

20 2620, 645 595/600, 620/625

595/1200, 620/1250

Special Designs

AK-02shiplap on all sides for screw mounting 3 600/600, 1200/600

625/625, 1250/625600/600, 1200/600625/625, 1250/625

AK-03shiplap on all sides with 5 mm bevel for screw mounting

600/600, 1200/600625/625, 1250/625

600/600, 1200/600625/625, 1250/625

SK-05shiplap on all sides for visible T-section

24 2 600/600, 1200/600625/625, 1250/625

594/594, 619/6191194/594, 1244/619

SK-06shiplap on all sides with 5 mm bevel for T-section 24 2 600/600, 1200/600

625/625, 1250/625594/594, 619/619

1194/594, 1244/619

VK-09**)concealed T-section for push-in mounting – panels grooved and bevelled on all sides (5 mm bevel)

35 3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

VK-10**)concealed T-section – panels can be disassembled – panels grooved and bevelled on all sides.

35 23

600/6001200/600

615/600615/1200

VK-12shiplap all round on alternating sides with 5 mm bevel. 2

31190/5901240/615

1200/6001250/625

System edges

SY-01straight edges on all sides, grooved on the long sides, undercut on the cross sides for modo ceiling system

600/6001200/600

596/6001200/596

SY-02lgrooved on the long sides, bevelled on all sides for Heradesign retaining claw

3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

1 The straight edge is not an exposed edge. Straight edge only produced at the express request of the customer.2 The billing dimensions or alternatively the ordering dimensions are always the grid dimensions.3 Installation pattern in cross joints requires very careful installation, because four visible panel edges have to meet at one point.

Edges: 1-layer Decorative

Heradesign® fine

Please note:***) Heradesign® plano: Panel thickness only 25 mm, max. width 600 mm; for edge VK-09: bevel only 3 mm

Heradesign® fine/A2: Panel thickness only 25 mm, max. width 600 mm

Attention:*) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness of 15 mm and edge SK-04.**) Custom formats only on request – length max. 1800 mm (contact technical customer service)

Page 15: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

15

Fire Protection – Building Component Classification for 1-layer Decorative PanelsHeradesign® fine

Construction Description * Classification Certificate

Heradesign® fine, d 25 mmin T-track system suspended as insertion installation, with Heralan DP-5 lining d 2 x 50 mm or with Heralan DP-4 lining d 2 x 60 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® fine, d 35 mmin T-track system suspended as insertion installation (VK-09), with Heralan DP-5 lining d 2 x 50 mm or with Heralan DP-4 lining d 2 x 60 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® fine, d 25 mmscrewed to wood laths 40/60 and suspended, with Heralan DP-5 lining d 80 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® fine, d 25 mmscrewed to CD sections and suspended, with Heralan DP-5 lining d 80 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® fine, d = 25 mmscrewed to wood laths 80/50, with Heralan DP-5 lining d = 50 mm

EI 30(a<—b)

Classification report No. MA39-VFA 2005-

05401.01 (A)

Reinforced concrete slab on IPE 140 supports with suspended counter ceiling made of Heradesign® fine panels, d = 35 mm, edge AK-01, screwed to sheet steel sections. Lining of 40 mm rock wool panel, RD = 100 kg/m2 on Heradesign panels and profiled sections.

F 30Counter ceiling alone,in combination withreinforced concrete

ceiling or wooden beam ceiling

Fire Protectionapproval

No Z 5818 ofVKF-AEAI from

Bern/CH,19.11.2003

* Attention: The classification only applies to the certified design. A reduction of the gross density of the mineral wool or the thickness of the lining or alternatively the panel thickness is not permitted. Only F 30 or F 60 certified hanging systems may be used as a substructure.

Page 16: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

16

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient according to ASTM – C423

Panel type

Without backfillingHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineWith mineral woolHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineWith flax woolHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fine

Panelthickness(mm)

1515252525252535353535

151525252525252525253535353535

0.120.180.250.750.360.210.350.750.440.75

0.390.430.750.850.840.490.850.850.840.80

0.780.970.950.650.690.980.950.600.680.65

1.040.890.700.700.700.870.650.800.770.70

0.650.630.650.700.730.670.800.700.790.85

0.530.790.850.850.770.730.850.800.720.85

0.700.750.750.750.750.750.800.750.750.75

CC

CC

C

0.70 (LMH)0.70 (LH)

0.75 (L)0.70 (L)

0.70 (LH)

0.100.40

0.100.30

0.35

15252525253535353535

3030402752303040130230275

303040403030401003040

2660126601

9666/WS9666/WS

2660126601

9666/WS9666/WS

266019666/WS

28.04.9428.04.9419.01.9819.01.9828.04.9428.04.9419.01.9819.01.9828.04.9419.01.98

s

s

p

p

s

s

p

p

s

p

302753080801001101102002753029060110210

30403080

80 PE50

80 PE110 PE

50403040606060

CH/EMPA DübendorfCH/EMPA DübendorfA/TGM WienD/Müller-BBMD/Müller-BBMTong Ji Uni ShanghaiD/Müller-BBMD/Müller-BBMTong Ji Uni ShanghaiA/TGM WienA/TGM WienCH/EMPA DübendorfCH/EMPA DübendorfCH/EMPA DübendorfCH/EMPA Dübendorf

D/Müller-BBMD/Müller-BBMA/TGM WienA/TGM WienD/Müller-BBMD/Müller-BBMA/TGM WienA/TGM WienD/Müller-BBMA/TGM Wien

186.074186.074

10225/WS1880818808

1880818808

10225/WS10656/AB119.203176.884176.884176.884

11.12.8511.12.8526.02.0112.11.9012.11.9004.03.0312.11.9012.11.9004.03.0326.02.0118.06.0309.04.7605.06.8405.06.8405.06.84

0.160.450.200.740.650.450.790.900.750.850.200.400.310.470.50

0.510.960.600.940.821.000.810.880.950.800.700.790.981.120.96

1.000.781.000.740.720.900.740.960.800.801.000.981.030.960.96

0.920.840.750.580.710.650.770.850.700.750.750.940.840.860.89

0.570.660.700.680.990.800.740.920.800.800.800.830.840.850.88

0.690.710.850.800.690.900.740.920.950.900.901.031.020.980.98

0.750.800.750.750.800.850.800.900.800.800.800.900.900.900.90

C

BB

03003080200300040100200

00000000000

CH/EMPA DübendorfCH/EMPA DübendorfA/TGM WienA/TGM WienA/TGM WienD/Müller-BBMA/TGM WienA/TGM WienD/Müller-BBMD/Müller-BBMD/Müller-BBM

186.074186.074

10225/WS10225/WS9821/WS

252999454/WS10225/WS

213072130721307

11.12.8511.12.8526.02.0126.02.0104.09.9818.10.9320.05.9726.02.0120.03.9220.03.9220.03.92

0.05

0.20

0.300.35

0.270.48

0.00

0.040.050.100.100.250.150.550.100.090.190.36

0.080.100.150.200.500.460.550.200.230.400.59

0.140.280.250.600.700.500.350.450.740.740.57

0.280.660.650.750.500.410.450.850.740.550.52

0.730.470.750.600.550.600.600.700.620.740.71

0.600.490.700.800.700.780.800.850.850.860.83

0.300.400.450.550.550.500.500.550.600.600.60

DDD

DD

0.35 (MH)0.50 (MH)0.55 (H)

0.45 (LH)0.45 (MH)

s

s

p

p

p

s

p

p

s

s

s

s

s

p

s

s

p

s

s

p

p

p

s

s

s

s

Spacingto ceiling (mm) 1)

Backfilling(mm)

Country/Test Institute No. Date s

p 63 125 250 500 1000 2000 4000 Absorber-class

wNRC2)entire range

Test item Certificates Degree of sound absorption s , pFrequencies (HZ)

0.75 (M)

0.800.80

Sound Absorption Values

Heradesign® fine

Page 17: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

17

Test item Construction Test Institute CertificatesNo. / Date

Results

Ceiling

Heradesign® fine,35 mm

Screw mounted under metal pro-filed sectionsCD sections 27 x 60 x 0.7 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3 x dry-wall screws/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-304.10.2005

“Safe against ball throwing“ as perDIN 18 032/ Part 3 orClass 1A as per EN13964 Appendix D

Heradesign® fine,35 mm

Screw mounting underwood laths 28/48 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3x Heradesignscrews/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-604.10.2005

“Safe against ball throwing“ as perDIN 18032/ Part 3 orClass 1A as perEN 13964 Appendix D

Heradesign® fine,35 mm

Push-in mounting,hung by means ofrigid hangers,in T-sections 24 x 38 mmEdge Design: VK-09

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

9013895-1/Sc/Kf

20.08.2007

“Safe against ball throwing“ as perDIN 18032/ Part 3 orClass 1A as perEN 13964 Appendix D

Wall

Heradesign® fine,35 mm

Screw mounted on wooden lathsWood lath dimensions 28 x48 mm, Centre distance 625 mmEdge Design: AK-01, Decorativepanels positioned horizontally.Fastening: 3 x wood screws/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-404.10.2005

“Safe against ball throwing“ as perDIN 18032/ Part 3 orClass 1A as perEN 13964 Appendix D

Design that is safe against ball throwing

according to DIN 18 032/Part 3

Heradesign® fine

Page 18: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

18

Heradesign® fine/A2

Magnesite -bound wood wool decorative panels of fine wood fibre structure with reaction to fire:Euroclasse A2-s1,d0 according EN 13501-1. Fibre width approx. 2 mm

Product TypeWW - EN 13168 - L3-W2-T1-S3-P2-CS(10)200-Cl3

Advantagesreaction to fire: Euroclass A2-s1,d0 regulation of climate in the roomdiffusion open structureall colours possible

recognised for organic building design

Application Acoustic and design covering for internal lining of ceilings and walls, where there are higher demands regarding fire protection.

Formats600 x 600, 1200 x 600 mm, edge design: AK-01,SK-04,VK-09

Colourswe recommend white (similar RAL 9010) or natural colour tone 13 (beige)

Note:Deviations in colour tone against colour chart and colour feeling are possible due to the rough fibre rep. panel surface.

Production tolerance, to nominal dimension: L3, W2: ± 1 mm, T1: +3/-2 mm, for lengths > 1250 mm L3: ± 2 mmFoil (thickness < 15 μm) recommended as drip protection for mineral wool layers.Maximum change of dimensions at standard operating environment 23° C/50 % rel. air humidity ±1 ‰

Limit of use:Max.span 600 mm.Suitable for use in enviroments having a continous rel. air humidity of up to 90 %. For conditions above 80 % rel air humidity constructional-physics advise is necessary.Do not glue panels against ceiling and walls!

Delivery programme:

Thickness [mm] 25 Weightt [kg/m²] 17,5 m²/packaging unit- standard formats:600 x 600. 1200 x 600 mm [m²] 50,40

Delivery form: palleted, with protective carton. Supplied only in complete packaging units! Special length, and other

edge finishings on request.

Page 19: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

19

Technical spezifications

Characteristic Symbol Description/Data Unit Standard

Fire behavior --- A2-s1, d0 [---] EN 13501-1Thickness d 25 [mm] EN 13168

Thermal conductivity D 0,095 [W/mK] EN 12667Thermal resistance RD 0,25 [m2K/W] EN 13168Flexural strength *) b >2200 [kPa] EN 12089 Diffusion resistance factor μ 5 [---] EN 12086

*) procedure A

Sound absorption coefficients p

Frequency (Hz) 125 250 500 1000 2000 4000 wAbsorberclasses

Heradesign® fine/A2, 25 mm4cm gap 0,05 0,25 0,65 0,60 0,50 0,70 0,50(H) D 28cm gap 0,50 0,65 0,40 0,40 0,60 0,75 0,45(LH) D

4cm gap /Heralan DP-5: 04cm 0,20 0,80 0,90 0,60 0,65 0,80 0,65(LMH)

C 8cm gap /Heralan DP-5: 08cm 0,55 1,00 0,80 0,65 0,65 0,80 0,70 (L) C 28cm gap /Heralan DP-5: 04cm 0,75 0,80 0,75 0,65 0,65 0,85 0,70 (LH) C

Figures for other designs on request

The installation of Heradesign panels is part of the interior works and have to be carried our under controlled humidity and temperature conditions. Any buildings activities which gives rise to dust and humidity have to be completed before starting installation of panels. Store panels flat and protect against humidity and dirt. Stack a maximum of two pallets, height maximum 250 cm. The packaging provided does not provide protection from rain. Please pay attention to the application, installation and storage guidelines of Heradesign panels.

For further information, please contact:

Heradesign Ceilings Division A business unit of Knauf Insulation GmbH A – 9702 Ferndorf 29 Phone: +43/4245-2001 3332 Fax: +43/4245-2001 3056 [email protected]

The present product data sheet corresponds with the current state of development of our products and will cease to be valid on publication of a new edition. Please check that you are using the latest edition of this information. The suitability of the product is not binding for special individualcases. Warranty and liability shall be in accordance with our Standard Terms of Business.

PGDB_Heradesign® fine/A2 01.04. 2008 (replace Version 01.05.2006 )

Page 20: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

20

Edges: 1-layer Decorative

Heradesign® fine/A2

Please note:***) Heradesign® plano: Panel thickness only 25 mm, max. width 600 mm; for edge VK-09: bevel only 3 mm

Heradesign® fine/A2: Panel thickness only 25 mm, max. width 600 mm

Attention:*) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness of 15 mm and edge SK-04.**) Custom formats only on request – length max. 1800 mm (contact technical customer service)

Abb

revi

atio

n

Des

ign

for

mm

Her

ades

ign®

fine/

A2*

**)

Rec

omm

. sec

tio n

wid

th

Com

men

ts

Grid

dim

ensi

ons

2) 3

)

Pan

el d

imen

sion

s

25 mm mm

Recommended standard edge designs and grid dimensions

GKstraight edge on all sides for screw mounting

13

600/6001200/600

600/6001200/600

AK-00bevelled on long sides (5 mm bevel) for screw mounting 3

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

AK-01bevelled on all sides (5 mm bevel) for screw mounting

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

SK-04*)straight edges only for visible T-section undercut as of 35 mm thickness 24 1

2600/600, 625/6251200/600, 1250/625

594/594, 619/6191194/594, 1244/619

SK-08straight on the long side, front side with bevelled edges for Omega section (5mm bevel)

20 2620, 645 595/600, 620/625

595/1200, 620/1250

Special Designs

AK-02shiplap on all sides for screw mounting 3 600/600, 1200/600

625/625, 1250/625600/600, 1200/600625/625, 1250/625

AK-03shiplap on all sides with 5 mm bevel for screw mounting

600/600, 1200/600625/625, 1250/625

600/600, 1200/600625/625, 1250/625

SK-05shiplap on all sides for visible T-section

24 2 600/600, 1200/600625/625, 1250/625

594/594, 619/6191194/594, 1244/619

SK-06shiplap on all sides with 5 mm bevel for T-section 24 2 600/600, 1200/600

625/625, 1250/625594/594, 619/619

1194/594, 1244/619

VK-09**)concealed T-section for push-in mounting – panels grooved and bevelled on all sides (5 mm bevel)

35 3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

VK-10**)concealed T-section – panels can be disassembled – panels grooved and bevelled on all sides.

35 23

600/6001200/600

615/600615/1200

VK-12shiplap all round on alternating sides with 5 mm bevel. 2

31190/5901240/615

1200/6001250/625

System edges

SY-01straight edges on all sides, grooved on the long sides, undercut on the cross sides for modo ceiling system

600/6001200/600

596/6001200/596

SY-02lgrooved on the long sides, bevelled on all sides for Heradesign retaining claw

3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

Page 21: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

21

Construction Description * Classification Certificate

Heradesign® fine/A2, d = 25 mmscrewed to wood laths 80/40, with Heralan DP-5 lining d = 40 mm

EI 30(a<—b)

Classification report No. MA39-VFA

2005- 0567.01 (A)

Heradesign® fine/A2, d = 25 mm screwed to CD sections 2 x 60/27, with Heralan DP-5 lining d 40 mm

EI 30(a<—b)

Classification report No.MA39-VFA

2006 0641.01 (A)

Fire Protection – Building Component Classification for 1-layer Decorative PanelsHeradesign® fine/A2

* Attention: The classification only applies to the certified design. A reduction of the gross density of the mineral wool or the thickness of the lining or alternatively the panel thickness is not permitted. Only F 30 or F 60 certified hanging systems may be used as a substructure.

Page 22: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

22

Without backfillingHeradesign® fine/A2 25 40 0 A/TGM Wien AB 11068 18.04.05 p 0.05 0.25 0.65 0.60 0.50 0.70 0.50 0.50 (H) DHeradesign® fine/A2 25 280 0 A/TGM Wien 18.04.05 p 0.50 0.65 0.40 0.40 0.60 0.75 0.50 0.45 (LH) DWith mineral woolHeradesign® fine/A2 25 40 40 A/TGM Wien AB 11068 18.04.05 p 0.20 0.80 0.90 0.60 0.65 0.80 0.70 0.65 (LMH) CHeradesign® fine/A2 25 80 80 A/TGM Wien AB 11068 18.04.05 p 0.55 1.10 0.80 0.65 0.65 0.80 0.80 0.70 (L) CHeradesign® fine/A2 25 280 40 A/TGM Wien AB 11068 18.04.05 p 0.75 0.80 0.75 0.65 0.65 0.85 0.70 0.70 (LH) C

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient as per ASTM - C423*) Ceiling layer coloured

Panel type Panelthickness

(mm)

Spacingto ceiling (mm) 1)

Backfilling (mm)

Country/TestInstitute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2) Absorber-class

entire range

Test item Certificates Degree of Sound Absorption s , pFrequencies (HZ)

Sound Absorption Values

Heradesign® fine/A2

Page 23: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

23

Test item Construction Test Institute Certificate No. / Date

Results

Ceiling

Heradesign® fine/A2,25 mm

Screw mounting under wood lath 28/48 mm, Centre distance 600 mm

D Research and materials testing institute, Baden-Württemberg, FMPA Stuttgart

55150/901 0354-704.10.2005

“ball throwing safe” according to DIN 18032/ Part 3 or class 1A according to EN 13,964 Appendix D

Design that is safe against ball throwing

according to DIN 18 032/Part 3

Heradesign® fine/A2

Page 24: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

24

Heradesign® micro

Magnesite-bound wood wool decorative panels of fine pored top surface.

Product Type: WW - EN 13168 - L3-W2-T2-S3-P2-CS(10)200-Cl3

Advantages regulation of climate in the room

diffusion open structureall colours possible

recognised for organic building design

Application offices, department stores, dwelling houses, schools, kindergartens, public offices, event halls, sports and multi purpose halls,

Formats600 x 600, 1200 x 600, 625 x 625, 1250 x 625 mm (max. lengths: 2500 mm, max. width: 625 mm)

Colours standard white (similar to RAL 9010) , natural colour tone 13 (beige)

Note:Deviations in colour tone against colour chart and colour feeling are possible due to the rough fibre rep. pnel surface.

Production tolerance, to nominal dimension: L3, W2, T2: ± 1 mm, for lengths > 1250 mm L3: ± 2 mmFoil (thickness < 15 μm) recommended as drip protection for mineral wool layers.Maximum change of dimensions at standard operating environment 23 °C/50% rel.air. humidity : ± 1‰

Limit of use:

Max. span 625 mm Suitable for use in environments having a continuous rel. air humidity of up to

90 %. For conditions above 80 % rel. air humidity constructional-physics advise is

necessary. Do not glue elements against ceiling and walls!

Delivery programme

Thickness [mm] 25 35 Weight [kg/m²] 14,5 18,5 m2/packaging unit-standard formats::600 x 600. 1200 x 600 mm [m²] 50,40 36,00625 x 625. 1250 x 625 mm [m²] 27,34 19,53

Delivery form: palleted, with protective carton. Supplied only in complete packaging units! Special length, and edge finishing, on request..

Page 25: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

25

Technical specifications

Characteristic Symbol Description/Data Unit Standard

Fire behaviour --- B-s1, d0 [---] EN 13501-1Thickness d 25 35 [mm] EN 13168

Thermal conductivity D 0,095 0,095 [W/mK] EN 12667Thermal resistance RD 0,25 0,35 [m2K/W] EN 13168Flexural strength *) b > 2000 [kPa] EN 12089 Diffusion resistance factor μ 5 5 [---] EN 12086

*according EN 12089, procedure A

Sound absorption coefficients p

Frequency (Hz) 125 250 500 1000 2000 4000 wAbsorber classes

Heradesign® micro, 25 mm3 cm gap 0,25 0,45 0,55 0,45 0,40 0,45 0,45 D30 cm gap 0,70 0,60 0,45 0,45 0,50 0,50 0,50(L) D3 cm gap /3 cm Heralan DP-5: 0,35 0,75 0,65 0,45 0,40 0,35 0,35(L) D27,5 cm gap / 4 cm Heraflax-SAP: 0,65 0,60 0,45 0,40 0,40 0,40 0,45(L) D

Heradesign® micro, 35 mmWithout gap 0,20 0,40 0,55 0,40 0,30 0,40 0,40 D3 cm gap /3 cm Heralan DP-5: 0 0,50 0,55 0,45 0,35 0,35 0,35 0,40(L) D

Figures for other designs on request.

The installation of Heradesign panels is part of the interior works and have to be carried our under controlled humidity and temperature conditions. Any buildings activities which gives rise to dust and humidity have to be completed before starting installation of panels. Store panels flat and protect against humidity and dirt. Stack a maximum of two pallets, height maximum 250 cm. The packaging provided does not provide protection from rain. Please pay attention to the application, installation and storage guidelines of Heradesign panels.

For further information, please contact:

Heradesign Ceilings Division A business unit of Knauf Insulation GmbH A – 9702 Ferndorf 29 Phone: +43/4245-2001 3332 Fax: +43/4245-2001 3056 [email protected]

The present product data sheet corresponds with the current state of development of our products and will cease to be valid on publication of a new edition. Please check that you are using the latest edition of this information. The suitability of the product is not binding for special individualcases. Warranty and liability shall be in accordance with our Standard Terms of Business.

PGDB_Heradesign® micro 01.04.2008 (replace Version 01.05.2006 )

Page 26: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

26

Edges: 1-layer Decorative

Heradesign® micro

Please note:***) Heradesign® plano: Panel thickness only 25 mm, max. width 600 mm; for edge VK-09: bevel only 3 mm

Heradesign® fine/A2: Panel thickness only 25 mm, max. width 600 mm

Attention:*) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness of 15 mm and edge SK-04.**) Custom formats only on request – length max. 1800 mm (contact technical customer service)

Abb

revi

atio

n

Des

ign

for

mm

Her

ades

ign®

mic

ro

Rec

omm

. sec

tio n

wid

th

Com

men

ts

Grid

dim

ensi

ons

2) 3

)

Pan

el d

imen

sion

s

25 35 mm mm

Recommended standard edge designs and grid dimensions

GKstraight edge on all sides for screw mounting

13

600/6001200/600

600/6001200/600

AK-00bevelled on long sides (5 mm bevel) for screw mounting 3

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

AK-01bevelled on all sides (5 mm bevel) for screw mounting

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

SK-04*)straight edges only for visible T-section undercut as of 35 mm thickness 24 1

2600/600, 625/6251200/600, 1250/625

594/594, 619/6191194/594, 1244/619

SK-08straight on the long side, front side with bevelled edges for Omega section (5mm bevel)

20 2620, 645 595/600, 620/625

595/1200, 620/1250

Special Designs

AK-02shiplap on all sides for screw mounting 3 600/600, 1200/600

625/625, 1250/625600/600, 1200/600625/625, 1250/625

AK-03shiplap on all sides with 5 mm bevel for screw mounting

600/600, 1200/600625/625, 1250/625

600/600, 1200/600625/625, 1250/625

SK-05shiplap on all sides for visible T-section

24 2 600/600, 1200/600625/625, 1250/625

594/594, 619/6191194/594, 1244/619

SK-06shiplap on all sides with 5 mm bevel for T-section 24 2 600/600, 1200/600

625/625, 1250/625594/594, 619/619

1194/594, 1244/619

VK-09**)concealed T-section for push-in mounting – panels grooved and bevelled on all sides (5 mm bevel)

35 3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

VK-10**)concealed T-section – panels can be disassembled – panels grooved and bevelled on all sides.

35 23

600/6001200/600

615/600615/1200

VK-12shiplap all round on alternating sides with 5 mm bevel. 2

31190/5901240/615

1200/6001250/625

System edges

SY-01straight edges on all sides, grooved on the long sides, undercut on the cross sides for modo ceiling system

600/6001200/600

596/6001200/596

SY-02lgrooved on the long sides, bevelled on all sides for Heradesign retaining claw

3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

1 The straight edge is not an exposed edge. Straight edge only produced at the express request of the customer.2 The billing dimensions or alternatively the ordering dimensions are always the grid dimensions.3 Installation pattern in cross joints requires very careful installation, because four visible panel edges have to meet at one point.

Page 27: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

27

Construction Description * Classification Certificate

Heradesign® micro, d 25 mmin T-track system suspended as insertion installation, with Heralan DP-5 lining d 2 x 50 mm or with Heralan DP-4 lining d 2 x 60 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® micro, d 35 mmin T-track system suspended as insertion installation (VK-09), with Heralan DP-5 lining d 2 x 50 mm or with Heralan DP-4 lining d 2 x 60 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® micro, d 25 mmscrewed to wood laths 40/60 and suspended, with Heralan DP-5 lining d 80 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® micro, d 25 mmscrewed to CD sections and suspended, with Heralan DP-5 lining d 80 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Reinforced concrete slab on IPE 140 supports with suspended counter ceiling made of Heradesign® micro panels, d = 25 mm, edge VK-12, screwed to wood laths.

F 30Counter ceiling alone,in combination withreinforced concrete

ceiling or wooden beam ceiling

Fire Protectionapproval

No Z 3251 of theVKF-AEAI Berne/CH,

19.11.2003

Fire Protection – Building Component Classification for 1-layer Decorative PanelsHeradesign® micro

* Attention: The classification only applies to the certified design. A reduction of the gross density of the mineral wool or the thickness of the lining or alternatively the panel thickness is not permitted. Only F 30 or F 60 certified hanging systems may be used as a substructure.

Page 28: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

28

Without backfillingHeradesign® micro 25 0 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 s 0.16 0.41 0.47 0.32 0.28 0.33 0.35 0.35 (L) DHeradesign® micro 25 30 0 A/TGM Wien 10656/AB 18.06.03 p 0.25 0.45 0.55 0.45 0.40 0.45 0.50 0.45 DHeradesign® micro 25 50 0 CH/EMPA Dübendorf 119.203 09.04.76 s 0.18 0.70 0.52 0.34 0.47 0.46 0.50 Heradesign® micro 25 300 0 A/TGM Wien 9454/WS 20.05.97 p 0.45 0.70 0.60 0.45 0.45 0.50 0.50 0.50 0.50 (L) DHeradesign® micro 35 0 0 A/TGM Wien 9454/WS 20.05.97 p 0.05 0.20 0.40 0.55 0.40 0.30 0.40 0.40 0.40 DWith mineral woolHeradesign® micro 25 30 30 A/TGM Wien 10225/WS 26.02.01 p 0.35 0.75 0.65 0.45 0.40 0.35 0.55 0.45 (L) DHeradesign® micro 25 275 40 A/TGM Wien 10656/AB 18.06.03 p 0.25 0.45 0.45 0.45 0.45 0.45 0.50 0.45 0.45Heradesign® micro 35 30 30 A/TGM Wien 10225/WS 26.02.01 p 0.50 0.55 0.45 0.35 0.35 0.35 0.45 0.40 (L) DWith flax woolHeradesign® micro 25 275 40 A/TGM Wien 9666/WS 19.01.98 p 0.45 0.65 0.60 0.45 0.40 0.40 0.40 0.45 0.45 (L) D

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient as per ASTM - C423*) Ceiling layer coloured

Panel type Panel

Thickness

(mm)

Spacingto ceiling (mm) 1)

Backfilling (mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2) Absorber-class

entire range

Test item Certificates Degree of Sound Absorption s , pFrequencies (HZ)

Sound Absorption Values

Heradesign® micro

Page 29: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

29

Design that is safe against ball throwing

according to DIN 18 032/Part 3

Heradesign® micro

Test item Construction Test Institute CertificatesNo. / Date

Results

Ceiling

Heradesign® micro,35 mm

Screw mounted under metal profiled sectionsCD sections 27 x 60 x 0.7 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3 x dry-wall screws/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-204.10.2005

“Safe against ball throwing“ as perDIN 18 032/ Part 3or Class 1A as per EN13964 Appendix D

Heradesign® micro,35 mm

Slide-in installation, hung by means of rigid hangers,in T-sections 24 x 38 mmCentre distance 600 mmEdge Design: VK-09

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

46/903 356-6/Sm/C10.06.2003

“Safe against ball throwing”as per DIN 18 032/ Part 3

Wall

Heradesign® micro,35 mm

Screw mounted on wooden laths,Wooden lath dimensions 28 x 48 mm

Centre distance 625 mmdecorative panels positioned horizontally. Fastening: 3 x wood screws/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-104.10.2005

“Safe against ball throwing“ as perDIN 18 032/ Part 3or Class 1A as per EN13964 Appendix D

Page 30: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

30

Heradesign® plano

Magnesite-bound wood wool decorative panels of fine pored, looking closed top surface.

Product TypeWW - EN 13168 - L3-W2-T2-S3-P2-CS(10)200-Cl3

Advantagesregulation of climate in the roomdiffusion open structure

all colours possible recognised for organic building design

ApplicationOffices, department stores,dwelling houses, public offices, school, kindergartens, events halls.

Formats 600 x 600, 1200 x 600 (max. lengths: 2400 mm)

Colour we recommend natural colour tone 13 ( beige)

Note: Deviations in colour tone against colour chart and colour feeling are possible

due to the rough fibre rep. panel surface. Production tolerance, to nominal dimension: L3, W2, T2: ± 1 mm, for lengths >

1250 mm L3: ± 2 mmFoil (thickness < 15 μm) recommended as drip protection for mineral wool layers.Maximum change of dimension at standard operating environment 23° C/50 % rel. air humidity ± 1 ‰Deliverable with SK-04 for visible T-sections and VK-09 for concealed T-sections.

Limit of use: Max. span 600 mmSuitable for use in environments having a continuous rel. air humidity of up to 90 %. For conditions above 80 % rel. air humidity constructional-physics advise is necessary.Do not glue panels against ceiling and walls!

Delivery programme

Thickness [mm] 25 Weight [kg/m²] 14,5 m2/packaging unit-standard formats:600 x 600. 1200 x 600 mm [m²] 50,40

Delivery form: palleted, with protective carton. Supplied only in complete packaging units! Special length, and other edge finishings, on request.

Page 31: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

31

Technical specifications

Characteristic Symbol Description/Data Unit Standard

Fire behaviour --- B-s1, d0 [---] EN 13501-1Thickness d 25 [mm] EN 13168

Thermal conductivity D 0,095 [W/mK] EN 12667Thermal resistance RD 0,25 [m2K/W] EN 13168Flexural strength *) b > 2000 [kPa] EN 12089 Diffusion resistance factor μ 5 [---] EN 12086

*) according EN 12089, procedure A

Sound absorption coefficients p

Frequency (Hz) 125 250 500 1000 2000 4000 wAbsorber classes

Heradesign® plano, 25 mmWithout gap 0,15 0,30 0,40 0,30 0,25 0,25 0,30 D3 cm gap 0,30 0,40 0,35 0,30 0,25 0,25 0,30(L) D27,5 cm gap 0,35 0,35 0,30 0,30 0,25 0,25 0,30(L) D3 cm gap /3 cm Heralan DP-3 0,40 0,40 0,35 0,25 0,25 0,25 0,30(L) D30,5 cm gap /4 cm Heralan DP-3 0,40 0,35 0,30 0,30 0,25 0,25 0,30(L) D

Figures for other designs on request.

The installation of Heradesign panels is part of the interior works and have to be carried our under controlled humidity and temperature conditions. Any buildings activities which gives rise to dust and humidity have to be completed before starting installation of panels. Store panels flat and protect against humidity and dirt. Stack a maximum of two pallets, height maximum 250 cm. The packaging provided does not provide protection from rain. Please pay attention to the application, installation and storage guidelines of Heradesign panels.

For further information, please contact:

Heradesign Ceilings Division A business unit of Knauf Insulation GmbH A – 9702 Ferndorf 29 Phone: +43/4245-2001 3332 Fax: +43/4245-2001 3056 [email protected]

The present product data sheet corresponds with the current state of development of our products and will cease to be valid on publication of a new edition. Please check that you are using the latest edition of this information. The suitability of the product is not binding for special individualcases. Warranty and liability shall be in accordance with our Standard Terms of Business.

PGDB_Heradesign® plano 01.04.2008 (replace Version 01.05.2006 )

Page 32: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

32

Edges: 1-layer Decorative

Heradesign® plano

Please note:***) Heradesign® plano: Panel thickness only 25 mm, max. width 600 mm; for edge VK-09: bevel only 3 mm

Heradesign® fine/A2: Panel thickness only 25 mm, max. width 600 mm

Attention:*) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness of 15 mm and edge SK-04.**) Custom formats only on request – length max. 1800 mm (contact technical customer service)

Abb

revi

atio

n

Des

ign

for

mm

Her

ades

ign®

plan

o***

)

Rec

omm

. sec

tio n

wid

th

Com

men

ts

Grid

dim

ensi

ons

2) 3

)

Pan

el d

imen

sion

s

25 mm mm

Recommended standard edge designs and grid dimensions

GKstraight edge on all sides for screw mounting

13

600/6001200/600

600/6001200/600

AK-00bevelled on long sides (5 mm bevel) for screw mounting 3

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

AK-01bevelled on all sides (5 mm bevel) for screw mounting

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

SK-04*)straight edges only for visible T-section undercut as of 35 mm thickness 24 1

2600/600, 625/6251200/600, 1250/625

594/594, 619/6191194/594, 1244/619

SK-08straight on the long side, front side with bevelled edges for Omega section (5mm bevel)

20 2620, 645 595/600, 620/625

595/1200, 620/1250

Special Designs

AK-02shiplap on all sides for screw mounting 3 600/600, 1200/600

625/625, 1250/625600/600, 1200/600625/625, 1250/625

AK-03shiplap on all sides with 5 mm bevel for screw mounting

600/600, 1200/600625/625, 1250/625

600/600, 1200/600625/625, 1250/625

SK-05shiplap on all sides for visible T-section

24 2 600/600, 1200/600625/625, 1250/625

594/594, 619/6191194/594, 1244/619

SK-06shiplap on all sides with 5 mm bevel for T-section 24 2 600/600, 1200/600

625/625, 1250/625594/594, 619/619

1194/594, 1244/619

VK-09**)concealed T-section for push-in mounting – panels grooved and bevelled on all sides (5 mm bevel)

35 3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

VK-10**)concealed T-section – panels can be disassembled – panels grooved and bevelled on all sides.

35 23

600/6001200/600

615/600615/1200

VK-12shiplap all round on alternating sides with 5 mm bevel. 2

31190/5901240/615

1200/6001250/625

System edges

SY-01straight edges on all sides, grooved on the long sides, undercut on the cross sides for modo ceiling system

600/6001200/600

596/6001200/596

SY-02lgrooved on the long sides, bevelled on all sides for Heradesign retaining claw

3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

1 The straight edge is not an exposed edge. Straight edge only produced at the express request of the customer.2 The billing dimensions or alternatively the ordering dimensions are always the grid dimensions.3 Installation pattern in cross joints requires very careful installation, because four visible panel edges have to meet at one

point.

Page 33: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

33

Sound Absorption Values

Heradesign® plano

Without backfillingHeradesign® plano 25 0 0 A/TGM Wien 10548/WS 04.07.02 p 0.15 0.30 0.40 0.30 0.25 0.25 0.30 0.30 DHeradesign® plano 25 30 0 A/TGM Wien 10548/WS 04.07.02 p 0.30 0.40 0.35 0.30 0.25 0.30 0.30 0.30 (L) DHeradesign® plano 25 275 0 A/TGM Wien 10548/WS 04.07.02 p 0.35 0.35 0.30 0.30 0.25 0.25 0.30 0.30 (L) DWith mineral woolHeradesign® plano 25 30 30 A/TGM Wien 10548/WS 04.07.02 p 0.40 0.40 0.35 0.25 0.25 0.25 0.30 0.30 (L) DHeradesign® plano 25 305 40 A/TGM Wien 10548/WS 04.07.02 p 0.40 0.35 0.30 0.30 0.25 0.25 0.30 0.30 (L) D

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient as per ASTM - C423*) Ceiling layer coloured

Panel type Panel

Thickness

(mm)

Spacingto ceiling (mm) 1)

Backfilling (mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2) Absorber-class

entire range

Test item Certificates Degree of Sound Absorption s , pFrequencies (HZ)

Page 34: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

34

Page 35: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

35

Product line TrendEdges

ColoursAccessories

Page 36: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

36

Edges: 1-layer Decorative

Please note:***) Heradesign® plano: Panel thickness only 25 mm, max. width 600 mm; for edge VK-09: bevel only 3 mm

Heradesign® fine/A2: Panel thickness only 25 mm, max. width 600 mm

Attention:*) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness of 15 mm and edge SK-04.**) Custom formats only on request – length max. 1800 mm (contact technical customer service)

Abb

revi

atio

n

Des

ign

for

mm

Her

ades

ign®

supe

rfine

Her

ades

ign®

fine

Her

ades

ign®

fine/

A2*

**)

Her

ades

ign®

mic

ro

Her

ades

ign®

plan

o***

)

Rec

omm

. sec

tio n

wid

th

Com

men

ts

Grid

dim

ensi

ons

2) 3

)

Pan

el d

imen

sion

s

15 25 35 15 25 35 25 25 35 25 mm mm

Recommended standard edge designs and grid dimensions

GKstraight edge on all sides for screw mounting

13

600/6001200/600

600/6001200/600

AK-00bevelled on long sides (5 mm bevel) for screw mounting 3

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

AK-01bevelled on all sides (5 mm bevel) for screw mounting

600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

SK-04*)straight edges only for visible T-section undercut as of 35 mm thickness 24 1

2600/600, 625/6251200/600, 1250/625

594/594, 619/6191194/594, 1244/619

SK-08straight on the long side, front side with bevelled edges for Omega section (5mm bevel)

20 2620, 645 595/600, 620/625

595/1200, 620/1250

Special Designs

AK-02shiplap on all sides for screw mounting 3 600/600, 1200/600

625/625, 1250/625600/600, 1200/600625/625, 1250/625

AK-03shiplap on all sides with 5 mm bevel for screw mounting

600/600, 1200/600625/625, 1250/625

600/600, 1200/600625/625, 1250/625

SK-05shiplap on all sides for visible T-section

24 2 600/600, 1200/600625/625, 1250/625

594/594, 619/6191194/594, 1244/619

SK-06shiplap on all sides with 5 mm bevel for T-section 24 2 600/600, 1200/600

625/625, 1250/625594/594, 619/619

1194/594, 1244/619

VK-09**)concealed T-section for push-in mounting – panels grooved and bevelled on all sides (5 mm bevel)

35 3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

VK-10**)concealed T-section – panels can be disassembled – panels grooved and bevelled on all sides.

35 23

600/6001200/600

615/600615/1200

VK-12shiplap all round on alternating sides with 5 mm bevel. 2

31190/5901240/615

1200/6001250/625

System edges

SY-01straight edges on all sides, grooved on the long sides, undercut on the cross sides for modo ceiling system

600/6001200/600

596/6001200/596

SY-02lgrooved on the long sides, bevelled on all sides for Heradesign retaining claw

3 600/600, 625/6251200/600, 1250/625

600/600, 625/6251200/600, 1250/625

1 The straight edge is not an exposed edge. Straight edge only produced at the express request of the customer.2 The billing dimensions or alternatively the ordering dimensions are always the grid dimensions.3 Installation pattern in cross joints requires very careful installation, because four visible panel edges have to meet at one point.

Page 37: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

37

AK-01AK-00GK

AK-03

VK-12SK-06

AK-02 SK-05

VK-09 VK-10

SK-04

SK-08

SY-01 SY-02

Edge Design/Details

Page 38: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

38

straight edge on all sides (5 mm bevel) for screw mounting

GK

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

600/600; 1200/600;

Grid dimensions (mm)

600/600; 1200/600;

shiplap all round on alternating sides with 5 mm bevel.

VK-12

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

1190/590; 1240/615

Grid dimensions (mm)

1200/600; 1250/625

Panel dimensions (mm)

shiplap on all sides with 5 mm bevel for

screw mounting

AK-03

Heradesign® superfineHeradesign® fine

Heradesign® microHeradesign® fine/A2

Product

600/600; 1200/600;625/625; 1250/625

600/600; 1200/600

Grid dimensions (mm)

600/600; 1200/600;625/625; 1250/625

600/600; 1200/600

Panel dimensions (mm)

shiplap on all sides for screw mounting

AK-02

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

600/600; 1200/600;625/625; 1250/625

Grid dimensions (mm)

600/600; 1200/600;625/625; 1250/625

Panel dimensions (mm)

Panel dimensions (mm)

bevelled on long sides (5 mm bevel) for screw mounting

AK-00

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

600/600; 1200/600;625/625; 1250/625

Grid dimensions (mm)

600/600; 1200/600;625/625; 1250/625

Panel dimensions (mm)

bevelled on all sides (5 mm bevel) for screw mounting

AK-01

Heradesign® superfineHeradesign® fine

Heradesign® microHeradesign® fine/A2Heradesign® industry

Product

600/600; 1200/600;625/625; 1250/625

600/600; 1200/600600/2400

Grid dimensions (mm)

600/600; 1200/600;625/625; 1250/625

600/600; 1200/600600/2400

Panel dimensions (mm)

Edge Design/Details

Page 39: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

39

5 5 5

10

20

30

5 5 5

10

20

30

d = 35 mmd = 25 mmd = 15 mm

10

17.5

15

17.5

1010

5

17.5

12.5

517

.517

.5 10

10

10

10

10

Paneldimensions

Paneldimensions

Griddimensions

15

25

35

Paneldimensions

Griddimensions

Griddimensions

Paneldimensions

Paneldimensions

Griddimensions

Griddimensions

Grid dimensions

Paneldimensions

Panel thickness = d

AK-00

GK

AK-01

AK-02

AK-03

VK-12

Edge Design/Details

Page 40: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

40

shiplap on all sides for visible T-section

SK-05

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

600/600; 1200/600;625/625; 1250/625

Grid dimensions (mm)

594/594; 1194/594;619/619; 1244/619

Panel dimensions (mm)

straight edges for visible T-section undercut as of

35 mm thickness

SK-04

Heradesign® superfineHeradesign® fine

Heradesign® microHeradesign® plano

Heradesign® fine/A2

Product

600/600; 1200/600;625/625; 1250/625

600/600; 1200/600

Grid dimensions (mm)

594/594; 1194/594;619/619; 1244/619

594/594; 1194/594

Panel dimensions (mm)

shiplap on all sides with 5 mm bevel for

T-section

SK-06

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

600/600; 1200/600;625/625; 1250/625

Grid dimensions (mm)

594/594; 1194/594;619/619; 1244/619

Panel dimensions (mm)

Edge Design/Details

Page 41: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

41

2015

d = 35 mmd = 25 mmd = 15 mm

6 6 6

17.5

12.5

10

5512

.5

17.5

17.5

1012

.5

66

6 6

Panel dimensions

Griddimensions

Panel dimensions

Panel dimensions

Griddimensions

Griddimensions

Panel thickness = d

SK-04

SK-05

SK-06

Edge Design/Details

Page 42: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

42

straight on long side,front side with bevelled edges

for Omega section (5 mm bevel)

SK-08

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

600, 645

Grid dimensions (mm)

595/600; 620/625;595/1200; 620/1250

Panel dimensions (mm)

concealed T-section- panel can be disas-sembled - panel groo-

ved and bevelled on all sides *)

VK-10

Heradesign® superfineHeradesign® fine

Heradesign® micro

Product

600

Grid dimensions (mm)

615/600; 615/1200;

Panel dimensions (mm)

*) only for grid dimensions 600 x 600 mm or alternatively 600 x 1200 and panel thickness 35 mm

**, bevel 3 mm

concealed slidingclips for push-inmounting, panelsgrooved on long

sides and undercut on cross sides,

straight edges on all sides 4 mm panel

joint

SY-01

Heradesign® superfine

Product

600

Grid dimensions (mm)

595/6001200/596

Panel dimensions (mm)

concealed T-section for push-in mounting, panels grooved and bevelled on all sides

(5 mm bevel)

VK-09

Heradesign® superfineHeradesign® fine

Heradesign® microHeradesign® fine/A2Heradesign® plano **

Product

600, 625600/600, 625/625

1200/600, 1250/625600, 600/600,

1200/600

Grid dimensions (mm)

600/600; 625/625;1200/600; 1250/625

600/600, 1200/600

Panel dimensions (mm)

For Heradesign®

retaining claw, grooved on long

sides, bevelled on all sides (5 mm bevel)

SY-02

Heradesign® superfineHeradesign® fine

Heradesign® microHeradesign® fine/A2Heradesign® plano **

Product

600, 625600/600, 625/625

1200/600, 1250/625600, 600/600,

1200/600

Grid dimensions (mm)

600/600; 625/625;1200/600; 1250/625

600/600, 1200/600

Panel dimensions (mm)

Edge Design/Details

Page 43: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

43

20

30

5 5

d = 35 mmd = 25 mm

113

65

15.5

11.5

35

7

7

17

20

17

20

Panel dimensions

Panel dimensions

Griddimensions

Griddimensions

10

Panel thickness = d

SK-08

VK-09

VK-10

SY-01

d = 25 mm

15.5

11.5

35

7

15817

40

Panel dimensions

Griddimensions

4

Paneldimensions

Griddimensions

d = 35 mmd = 25 mm

5 5

20

30

113

65

15.5

11.5

35

7

17

20

17

20

Panel dimensions

Griddimensions

SY-02(long side)

SY-02(front side)

Edge Design/Details

Page 44: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

44

Colour Variations for Decorative Panels, 1-Layer

On requestOther colouring is available based on standardised colouring systems such as RAL, NCS or StoColor. In addition, there is the possibility of applying metallic colours and motifs.• Deviations in the colouring compared to the colour card and colour percepti-on are possible as a result of the rough fibre or panel surface. • Please observe surcharge rates and minimum orders.

ApplicationsPicture format:Max.: 3000 x 6000 mmMin.: 600 x 600 mm

(Panel formats: 1200 x 600, 600 x 600 mm)

Artwork:The motifs (pictures) must be provided on a mass storage device and as a colour print.Mass storage device: CD-ROM or email, in TIF format or JPG formatThe digital resolution is dependent on the visual distances to the motifs when installed.100 cm 150 dpi; 150 cm 100 dpi; 300 cm 80 dpi

Recommendation: Colouring selection using the StoColor system

1) Quantities less than 150 m2 can not be coloured mechanically. On request, we can colour them manually (deviations in the look from mechanically coloured panels are possible).

2) Surcharge rates according to the StoColor system

Price group 1: The following pastel colours according to “RAL 840 HR” are possible:

Surcharge rates: Price groups apply to colouring as of 300m2

1000 green-beige1001 beige1002 sand yellow1013 pearl white1014 ivory1015 light ivory

1034 pastel yellow3012 beige-red3014 antique rose5012 light blue5014 dove blue5024 pastel blue

6013 reed green6019 white-green6021 pale green6034 pastel turquoise 7004 signal grey7032 pebble grey

7035 light grey7038 agate grey7044 silk grey9001 cream white9002 grey white9018 papyrus white

All other RAL coloursare solid colours

Price group 1 Pastel colours C1 2), C2 2)

Price group 2 Solid colours C3 2)

Price group 3 Metallic colours Surcharge for minimum amount of 150 – 300 m2 1)

flat rate/net

Heradesign® superfine, Heradesign® fine • White, similar to RAL 9010

Heradesign® fine/A2, Heradesign® micro • Natural tone 13 (beige)

Heradesign® plano • Natural tone 13 (beige)

Heradesign® industry • Grey, similar to RAL 7035

Heradesign® agro • White, similar to RAL 9010

Standard ColoursHeradesign decorative panels are delivered as follows by default:

Page 45: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

45

Paint with a Function

Active interior paint - StoClimasan Color

The Sto principle: When light becomes fresh air!

For a permanently improved room climate, Heradesign deco-rative panels (except for Heradesign® fine/A2) can be coated with the photo-catalytic colour StoClimasan Color.

After applying StoClimasan Color, an active reduction of organic air pollutants takes place under the effect of light.

Above all, Heradesign® superfine and Heradesign® finewith their fine fibre structures intensify the outstanding effect of StoClimasan Color.

Functional Principle

StoClimasan Color is a coating material that constantly redu-ces contaminants and odours. The photo-catalytic pigment is responsible for this, which generates this special active effect under visible light.

Ultimately, organic compounds except for water and carbon dioxide are broken down permanently under the influence of light!

Applications

Expert reports from well-known testing institutes confirm the functionality and the active improvement of the interior air due to StoClimasan Color.Preferred areas of applications are heavily burdened rooms and areas of buildings in schools, kindergartens, restaurants (especially in the kitchen), hospitals, airports, and train stati-ons (e.g. in the smoking zone).

Limited range of colours according to StoColor.

Materials and gasses floating in the room air contact the coated surface of the walls and ceiling.

Light activates the catalyst in the coating and breaks the materials down to their basic components on the boundary surface.

The result is noticeably better room air.

Page 46: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

46

StoClimasan Color Colour Chart based on StoColor System

Page 47: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

47

Metallic Colours

Brilliant colour effects with fascinating metallic paintsThe lively and characteristic surfaces of Heradesign decorative panels are perfectly suited for creating spectacular colour effects. Discover the new metallic collection and use it to create an effective flair for walls and ceilings.The system cooperation with Sto AG, internatio-nal paint specialists, makes it possible to always have new colour compositions and colour effects – just like this new metallic collection. StoColor Metallic is a metalizing, very resilient, decorative coating that conjures up an irresistible metallic colour effect.

Attention!Since the metallic effect is mainly a result of the interplay between the panel surface and the light situation, sampling is absolutely necessary. Based on our experience, we offer metallic paint coating for the following Heradesign products:

Heradesign® superfine,Heradesign® fine,Heradesign® micro,Acoustic elements with a mineral wool core(without Heradesign® plano as a visual surface).

Page 48: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

48

32809MMetallic salmon red

34809MMetallic dark blue

34800MMetallic dark violet

35800MMetallic grey-blue

34806MMetallic blue-violet

35801MMetallic light blue

34808MMetallic silver violet

35808MMetallic turquoise

36800MMetallic sea green

37806MMetallic grey-aluminium

37807MMetallic white aluminium

37808MMetallic iron mica

Heradesign Metallic Collection

The following 12 metallic colours are available:

The colouring is only suitable for use indoors!

Page 49: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

49

Eleven special colours are especially well suited for applications without daylight. They provide a friendly atmosphere and a nice, secure feeling.

Sto 35415 Sto 36102

Sto 34406 Sto 35110

Sto 31309 Sto 31303

Sto 32207 Sto 32203

Sto 37111 Sto weiss

Sto 35805M

Well-Being Effect without Daylight

Sto white

Page 50: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

50

Heradesign Ceiling BracketAs an independent design element, the Heradesign cei-ling bracket is used for both covering structural elements as well as for individual ceiling and wall design. Made of Heradesign decorative panels, the ceiling bracket is convincing due to the lively surface as well as the tried and proven acoustic and optical properties. It can be coloured in almost any colour on request.

Thickness: 25,35 mm

Formats: Max. length 1.250 mmmax. width 600 mm (straightening the angle leg)

Edge Design: GK, AK-01

Properties: Heradesign ceiling brackets are dimen-sionally stable and cut on mitres. They are made of Heradesign acoustic panels and consequently match their product data.

Colours:Standard: • White, similar to RAL 9010 • Natural tone 13 (beige)On request: • Other colouring is available based on standardised colouring systems such as RAL, NCS or StoColor. • It is also possible to apply metallic colours, StoClimasan Color, and motifs.Recommendation: • Colouring selection using the StoColor system.

Accessories for Decorative Panels,

1-Layer, Ceiling Bracket

Please note: For F 30/EI 30 ceilings with screw instal-

lation, the panels must be additionally connected on the

inside angel side by a scantling 50/50 mm or alterna-

tively by a CD section.

WL. . . . Angle length SL . . . . leg length

Leg length + leg length = max. width

SL

SL

WL

Panel thickness (mm) Decorative panel Weight* ca. kg/m2

Formatlength x width mm

25; 35

Heradesign® superfine 10.8; 15.0

max. 1.250 x 600Heradesign® fine 12.0; 16.0

Heradesign® micro 14.5; 18.5

25 Heradesign® plano 14.5 max. 1.200 x 600

Standard Colours: white, similar to RAL 9010, natural tone 13 (beige). Edge design GK, AK-01. Max. width corresponds to straightening the angle leg. *Delivery time and design possibilities on request.

Page 51: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

51

Accessories for Decorative Panels,

1-Layer, Maintenance Opening

Heradesign® Maintenance OpeningFrame

Heradesign® Maintenance Openingwith Heradesign acoustic panel as the visual surface

Maintenance opening specially for Heradesign decorative panels for installation in ceilings and wall structures.

Design: consists of two aluminium frames with a pressu-re lock and safety catch.

Section thickness: ca. 2 mm

Area of application: for suspended ceiling constructions and wall installations without any fire exposure where permanent access to the wall or ceiling cavity is required (e.g.: service work).

Delivery form: in boxes, post paid as additional freight.

Design: Maintenance opening consisting of two alumi-nium frames that can’t be disassembled with a pressure lock and safety catch built into a Heradesign decorative panel. The maintenance opening is centred in the panel by default.High-quality solution through assembly at the plant.

Section thickness: ca. 2 mm

Area of application: for suspended ceiling constructions and wall installations without any fire exposure where permanent access to the wall or ceiling cavity is required (e.g.: service work).

Delivery form: in boxes, post paid as additional freight.

600 x 600 400 x 400 25 1*)

625 x 625 400 x 400 25 1*)

*) Packaging units can be defined individually depending on the quantity ordered.

Panel- Maintenance- For panel- Packaging-format opening thickness units

dimensions mm mm pieces/box

Dimensions For panel- Weight Packaging units mm thickness mm kg pieces/box

400 x 400 25 1,1 1*)400 x 600 25 1,2 1*)

*) Packaging units can be defined individually depending on the quantity ordered.

Page 52: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

52

Accessories for Decorative Panels,

1-Layer, Retaining Claw

With the Heradesign retaining claw, installation of the Heradesign decorative panels on ceilings, walls, and even on pitched roofs becomes even easier. The rustproof assembly profile facilitates concealed applications, which are always true to size. After installation, the fastener is no longer visible.

Concealed ceiling, wall, and pitched roof installation system.

Rust-protected assembly section for concealed fastening of Heradesign decorative panels.

Area of application: as an invisible ceiling, wall, and pitched roof section

Design: edged, pre-galvanised slit strips 1mm, drill hole 5mm.

Installation: approx. 3 retaining claws for each m2,each with 4 screws min 4.5/25

Heradesign Retaining Claw

A perfect joint seal with the Heradesign retaining claws

Type Dimensions mm For panel thickness mm Packaging unitspieces/box

Standard profile 135 x 45 25, 35 100End profile 135 x 30 25, 35 100

Page 53: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

53

Accessories for Decorative Panels,

1-Layer, Screws

Concrete Screws DDS *)Rust-protected screw with a special thread and screw head with wood wool texture for attaching 1 and 2-layer Heradesign decorative panels to concrete. Screw head with TORX T 30 and plastic coating in fibre structure; colour white or beige.

Head diameter: ca. 25 mmDrill hole diameter: 6 mmInsertion depth: ca. 25 mmService load: ca. 0.3 kN per screw

Requirements:at least 5 screws/panel for the format 1200/600 mmDelivery form: in boxesDelivery only in complete packaging units.Note: Check the surface of the concrete for evenness.

Heradesign Screws

Rust protected, universal dry-wall screw for attaching Heradesign decorative panels to laths and CD sections. Partial thread, screw head with Torx T20Requirements: depending on the width of the panel and the centre distance, at least 2 screws; version that is safe against ball throwing at least 3 pieces

Minimum spacing: 600 or 300 mm respectively 625 or 312 mm respectivelyPlease note: Not suitable for indoor swimming pools.Delivery form: in boxes. Delivery only in completepackaging units, post paid as additional freight

Dimensions mm For panel thickness mm Packaging units pieces/boxLength Ø

50 4.5 25 20060 4.5 35 200

*) On request, a powder-coated version is available in all popular dimensions for corrosion resistance. (plastic screw head without fibre structure)

Length mm For panel thickness mm Colour Packaging units pieces/box

50 25 white or beige 10075 35 and 50 white or beige 100100 75 white or beige 100125 100 white or beige 100150 125 white or beige 100

Concrete Decorative ScrewsRust-protected, painted steel screws consisting of screw and disc with special thread*, Screw head with TORX T 30. Screw and disc with metallic painting.

Heat/disc diameter: 15 mm / 42 mmDrill hole diameter: 6 mmInsertion depth: ca. 25 mmService load: ca. 0.3 kN per screwRequirements: at least 5 screws/panel for the format 1200/600 mmDelivery form: in boxes

Delivery only in complete packaging units.Note: Check the surface of the concrete for evenness.

* For fastening 1 and 2-layer Heradesign decorative panels to concrete.

Length mm For panel thickness mm Colour Packaging units (screws & disc) pieces of each / box

125 100 metallic silver 100/100150 125 metallic silver 100/100

Page 54: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

54

Page 55: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

55

Product line TrendOpen Systems

modo Ceiling System

Page 56: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

56

modo Ceiling System

The effect of the complete solution is captivating for large size surfaces. It provides an impressive, closed ceiling area. The system consists of three compon-ents: the Heradesign® superfine decorative panels, the

tracks, and the system clips. The style of installation is easier and faster than you think, i.e. a stretcher bond with shadow gap, an exact, straight edge and innova-tive clip mounting.

Product Thickness mm Weight kg/m2

Edge Design Track spacing Panel Dimensions mm

Heradesign® superfine 25 10,8 SY-01 600600/5961200/596

Please note: Width of the panel joints: 4 mm on all sidesThe modo ceiling system is not suitable for swimming pools, sports halls, and outdoor applications.

Page 57: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

57

Heradesign® superfine

SY-01

Concealed sliding clips for push-in mounting, panels grooved on the long sides and under-cut on the cross sides, straight edge on all sides, 4 mm panel joint

4

Edge Design: SY-01

The complete system as delivered consists of the Heradesign® superfine decorative panels, tracks, and the specific holders.

System Components:

Tracks / Holders

modo Processing Primer

For processing information see the “modo Processing Primer“

Grid s ize

Panel S ize

Page 58: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

58

Page 59: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

59

Product line TrendDecorative 2-layer panels

Page 60: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

60

Heradesign® micro plus

2-layer, magnesite bonded, wood wool decorative panel with fine pored surface and glued-on rock wool layer.

Product Type Heradesign® micro plus, WW - EN 13168 - L3-W2-T2-S3-P2-CS(10)200-Cl3 Heralan stone wool, MW - EN 13162 - T4-DS(T+)-TR1-WS-WL(P)

AdvantagesHeralan stone wool: non-combustible, A1 accord. to EN 133501-1high thermal insulationstable surfaceeasy to work with

ApplicationBasements, underground and multi storey car parks, multi purpose buildings, industrial halls.

Formats1200 x 600 mm; edge design: AK-01

Colours We recommend white ( similar RAL 9010) or natural tone 13 (beige)

Note:Deviations in colour tone against colour chart and colour feeling are possible due to the rough fibre rep.panel surface. Maximum change of dimensions at standard operating environment 23 °C/50 % rel. air humidity max: ± 1 ‰ Fixing to solid concrete slabs with Heraklith DDS concrete screws of Heraklith DM R stainless steel dowel, minimum 2 or 5 pieces per panel

Limit of use: Max. span 600 mm

Suitable for use in environments having a continuous rel. air humidity of up to 90 %. For conditions above 80 % rel. air humidity constructional physics advise is necessary.

Do not glue panels against ceilings and walls! Delivery programme

Thickness [mm] 100 125Ply construction micro plus Heralan

[mm][mm]

2575

25100

Weight [kg/m²] 21,0 23,0 Format [mm] 1200 x 600

Delivery form: palleted, with protective carton. Supplied only in complete packaging units!

Page 61: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

61

Technical specifications

Characteristic Symbol Description/Data Unit StandardFire behavior of micro plus Fire behavior of Heralan --- B-s1, d0

A1[---] ÖN EN 13501-1

Thickness d 100 125 [mm] ÖN EN 13168

Thermal coductivity of: micro plus

Thermal coductivity of: Heralan DP-9D

0,095

0,037

0,095

0,037[W/mK] ÖN EN 12667

Thermal resistance RD 2,25 2,95 [m2K/W ÖN EN 13168

Flexural strength micro plus *) b >2000 >2000 [kPa] ÖN EN 12089

Diffusion resistance value micro plus Diffusion resistance value of Heralan μ

5 1

5 1

[---] ÖN EN 12086

*) According procedure A of EN 12089

Sound absorption values p

Frequency (Hz) 125 250 500 1000 2000 4000 NRC w

Heradesign® micro plus, 25 mm + 105 mm Heralan Stone woolWithout gap 0,47 0,40 0,35 0,29 0,29 0,33 0,35 0,35(L)

Figures for other designs on request

The installation of Heradesign panels is part of the interior works and have to be carried our under controlled humidity and temperature conditions. Any buildings activities which gives rise to dust and humidity have to be completed before starting installation of panels. Store panels flat and protect against humidity and dirt. Stack a maximum of two pallets, height maximum 250 cm. The packaging provided does not provide protection from rain. Please pay attention to the application, installation and storage guidelines of Heradesign elements.

For further information, please contact:

Heradesign Ceilings Division A business unit of Knauf Insulation GmbH A – 9702 Ferndorf 29 Phone: +43/4245-2001 3332 Fax: +43/4245-2001 3056 [email protected]

The present product data sheet corresponds with the current state of development of our products and will cease to be valid on publication of a new edition. Please check that you are using the latest edition of this information. The suitability of the product is not binding for special individualcases. Warranty and liability shall be in accordance with our Standard Terms of Business.

PGDB_Heradesign® micro plus 01.04.2008 (replace Version 01.05.2006 )

Page 62: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

62

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient as per ASTM - C423*) Ceiling layer coloured

pacingto ceiling (mm) 1)

Panel type Thick-totalness(mm)

Element construction

Ceiling Corelayer(mm) (mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000

Test item Certificates Degree of sound absorption pentire range

wNRC2) Absorber-class

Frequencies (HZ)

Without backfilling130 25 *) 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.69 0.86 0.96 0.95 0.93 1.00 0.95 0.95 A125 15 110 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.10 0.33 0.41 0.42 0.71 0.84 0.45 0.45 (H) D80 15 65 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.05 0.12 0.37 0.42 0.68 0.82 0.40 0.35 (H) D130 25 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.79 0.91 0.91 0.81 0.81 0.84 0.90 0.85 (L) B125 15 110 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.11 0.31 0.43 0.42 0.79 0.86 0.45 0.45 (H) D90 25 65 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.07 0.19 0.50 0.80 0.78 0.77 0.55 0.50 (MH) D130 25 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.47 0.40 0.35 0.29 0.29 0.33 0.35 0.35 (L) D130 25 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.15 0.44 0.48 0.42 0.32 0.32 0.45 0.40 (L) D90 25 65 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.13 0.36 0.43 0.30 0.25 0.26 0.35 0.30 (L) D

Heradesign® superfine 25 mm/MWHeradesign® superfine 15 mm/EPSHeradesign® superfine 15 mm/PFHeradesign® fine 25 mm/MWHeradesign® fine 15 mm/EPSHeradesign® fine 25 mm/PFHeradesign® micro plusHeradesign® micro 25 mm/EPSHeradesign® micro 25 mm/PF

Sound Absorption Values

Acoustic Elements

Page 63: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

63

Page 64: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

64

Page 65: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

65

Product line ExecutiveDecorative 3-layer panels

Page 66: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

66

Heradesign® style3-layer, magnesite bonded wood wool decorative panel with HPL coating on both sides (Micro-perforation: 5/5-

1.3 mm). Closed surface with top acoustic absorption values.

Product Description Code

WW-EN 13168-L3-W2-T2-S3-P2-CS(10-Y) 20-TR5-Cl3

Special Product Features

3-layer, acoustically effective decorative productwood wool absorber core coated on both sidesby default, the edge is designed with the decorative coating and colour coating = HPL (High Pressure Laminate)panel has only one exposed side – the back is designed as blind HPLcoating is perforated

Scope of Applications

for covering wall and ceiling surfaces in commercially available, standardised, installation systems for acoustically effective and decorative purposes; installation recommendations and standard edge designs can be requested at www.heradesign.at.

Sizes (standard)

600 x 600, 1200 x 600 mm (pre-cut or fitting pieces possible on request)

Colours – Surface (standard)

choice of 72 decorative colours based on the Argolite Uni collection – surface quality matt aluminium

Perforation

linear perforation 5/5 – 1.3 mm with 10 mm perforation-free edge on overleaf

Attention:

The HPL decorations from the Argolite collection are colour consistent. If custom colours from RAL or NCS are selected where a paint coating is needed, then minor colour deviations can't be completely excluded in spite of close monitoring of the colour mixing.

manufacturing tolerance of nominal dimensions as per product declaration: length ± 1 mm, width ± 1 mm, thickness ± 1 mmmaximum dimensional changes in a standard climate of 23 C/50% rel. humidity is 1%

max. span is 600 mm For 3-layer Heradesign decorative panels, it is necessary to not exceed relative air humidity of 35 – 65% at 10 - 35 C when working with the panels (processing conditions). High construction humidity can have negative consequences.not suitable for glue mounting.

Page 67: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

67

Delivery form

Thickness [mm] 25.0 Weight [kg/m²] approx. 17.5 m2/packaging unit for standard format600 x 600 mm [m²] 18.01,200 x 600 mm [m²] 18.0

Degree of sound absorption p

Frequency (Hz) 125 250 500 1000 2000 4000 wAbsorber

Kl

Herakustik® style, 25 mm 1. Dist.: 275mm/Heralan AP-GS 40mm 0.58 0.77 0.85 0.73 0.83 0.63 0.80 B2. Dist.: 040mm/Heralan AP-GS 40mm 0.23 0.98 0.96 0.70 0.81 0.60 0.80 (L) B3. Dist.: 040mm 0.04 0.25 0.76 0.59 0.59 0.56 0.55 D

Additional sound absorption values on request

Technical Data – Product Construction

1. Heradesign® Absorber Core

Properties Symbol Data Units Standard

Reaction to fire --- A2-s1, d0 [---] EN 13501-1Thickness D 25 [mm] EN 13168

Nominal value of thermal conductivity D 0.095 [W/mK] EN 12667Thermal resistance RD 0.25 [m2K/W] EN 13168

Bending resistance *) b >2200 [kPa] EN 12089 Diffusion resistance value μ 5 [---] EN 12086

*) As per method A of EN 12089

2. Coating

laminate standard = HPL (High Pressure Laminate)thickness 0.8 mmsurface quality matt aluminium (satin or high-gloss on request)colours according to RAL or NCS are possiblemeets the highest demands regarding resistance to impact, scratching, and abrasion as per EN 438 / ISO 4586light-fast and stable colour

Page 68: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

68

Alternative flame resistant version available!Standard B1 (Germany) and M1 (France)

3. Perforation

Perforation pattern – linear grid

Handling and Storage

The installation of Heradesign decorative panels is part of interior decorating and must only be carried out under controlled humidity and temperature conditions. All dust-causing construction measures must be completed before starting the installation. Store panels level to plane and protect against moisture and soiling. The packaging doesn’t protect the product against rain!Therefore, these products must be very specifically protected against moisture at the construction site. Absolute dry storage is mandatory. When sorting or laying out the panels, the supplied protective film must always be used between the panels. In this connection, please also observe the possibility of rising damp in new buildings.Observe the relevant application, installation, and storage guidelines for Heradesign products.

Planning Service

Heradesign offers a special CAD planning service for the Heradesign style product. On one hand, this makes exact planning of the ceiling face possible. On the other hand, exact calculation of the order quantity is also possible. With this service, it is also possible to have special fitting pieces produced. You can obtain more detailed information from our technical customer service and at www.heradesign.at.

Distribution is handled via specialised trade.

Coating Composition: overlay for imprinted decorations decorative paper multi-layer craft paper

Open space: 5.0% Grid/Perforation: 5/5 – 1.3

Page 69: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

69

Heradesign Ceilings DivisionA business unit of Knauf Insulation GmbHA – 9702 Ferndorf 29 Tel: +43/4245-2001 3332Fax: +43/4245-2001 [email protected]

The product data sheet presented here corresponds to the current state of development of our products and loses its validity when a new issue appears. Always make sure that you are using the latest issue of this information in each case. The suitability of the product is not binding for exceptional isolated cases. The guarantee and liability upon delivery are orientated around our general terms and conditions. No responsibility is assumed for the correctness of this information.

Datenblatt_Heradesign® style 01.03.2008 (replaces version 01.02.2007)

Page 70: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

70

Colors, 3-Layer Decorative Panels

Heradesign® style

• 72 NCS colours in the Argolite collection

• Other colours according to RAL and NCS are possible

• Surface standards: matt, satin, high-gloss

• The edge is designed with the same colour as the surface.

Page 71: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

71

Heradesign® deluxe3-layer, magnesite bonded wood wool decorative panel with real wood veneer on HPL on both sides (Micro-

perforation: 5/5- 1.3 mm). Closed surface with top acoustic absorption values.

Product Description Code

WW-EN 13168-L3-W2-T2-S3-P2-CS(10-Y) 20-TR5-Cl3

Special Product Features

3-layer, acoustically effective decorative productwood wool absorber core coated on both sidescoating = HPL with real wood veneer by default, the edge is designed with the veneer and grain panel has only one exposed side – back is designed as blind veneercoating is perforated

Scope of Applications

for covering wall and ceiling surfaces in commercially available, standardised, installation systems for acoustically effective and decorative purposes; installation recommendations and standard edge designs can be requested at www.heradesign.at.

Sizes (standard)

600 x 600, 1200 x 600 mm (pre-cut or fitting pieces possible on request)

Veneers – Surface (standard)

choice of 9 standard veneers (fir, maple, American walnut, birch, beech, European oak, European ash, pine, American cherry wood) in shifted wire/half wire.

Perforation

linear perforation 5/5 – 1.3 mm with 10 mm perforation-free edge on overleaf

Page 72: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

72

Attention:

The HPL bases with real wood veneer are wire/half wire shifted as a standard. Irregularities in the growth, swirls, deviations in the grain and colour are natural.For large quantities, you must specify which panels will be installed in the same room or on the same wall because of the veneer colour. One must proceed on the assumption that different veneer sources may be used.The characteristics of natural wood surfaces given here are permissible according to a defined tolerance framework and are not subject to complaints. We recommend sorting the elements before installation!The colour of stained or painted surfaces may deviate from samples prepared in advance. The same also applies to the lustre of the coating.

manufacturing tolerance of nominal dimensions as per product declaration: length ± 1 mm, width ± 1 mm, thickness ± 1 mmMaximum dimensional changes in a standard climate of 23 C/50% rel. humidity is 1% max. span is 600 mm For 3-layer Heradesign decorative panels, it is necessary to not exceed relative air humidity of 35 – 65% at 10 - 35 C when working with the panels (processing conditions). High construction humidity can have negative consequences.not suitable for glue mounting.

Delivery form

Thickness [mm] 25.0 Weight [kg/m²] approx. 17.5 m2/packaging unit for standard format600 x 600 mm [m²] 18.01,200 x 600 mm [m²] 18.0

Degree of sound absorption p

Frequency (Hz) 125 250 500 1000 2000 4000 wAbsorber

Kl

Herakustik® deluxe, 25 mm 1. Dist.: 275mm/Heralan AP-GS 40mm 0.58 0.77 0.85 0.73 0.83 0.63 0.80 B2. Dist.: 040mm/Heralan AP-GS 40mm 0.23 0.98 0.96 0.70 0.81 0.60 0.80 (L) B3. Dist.: 040mm 0.04 0.25 0.76 0.59 0.59 0.56 0.55 D

Additional sound absorption values on request

Page 73: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

73

Technical Data – Product Construction

1. Heradesign® Absorber Core

Properties Symbol Data Units Standard

Reaction to fire --- A2-s1, d0 [---] EN 13501-1Thickness d 25 [mm] EN 13168

Nominal value of thermal d i i

D 0.095 [W/mK] EN 12667Thermal resistance RD 0.25 [m2K/W] EN 13168

Bending resistance *) b >2200 [kPa] EN 12089 Diffusion resistance value μ 5 [---] EN 12086

*) As per method A of EN 12089

2. Coating

HPL (= High Pressure Laminate) with 0.2 mm real wood veneerthickness 0.8 mmveneer pattern in shifted wire/half wiregenuine natural material

3. Perforation

Perforation pattern – linear grid

Coating Composition: overlay for imprinted decorations decorative paper multi-layer craft paper

Open space: 5.0% Grid/Perforation: 5/5 – 1.3

Page 74: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

74

Handling and Storage

The installation of Heradesign® decorative panels is part of interior decorating and must only be carried out under controlled humidity and temperature conditions. All dust-causing construction measures must be completed before starting the installation. Store panels level to plane and protect against moisture and soiling. The packaging doesn’t protect the product against rain!Therefore, these products must be very specifically protected against moisture at the construction site. Absolute dry storage is mandatory. When sorting or laying out the panels, the supplied protective film must always be used between the panels. In this connection, please also observe the possibility of rising damp in new buildings.Observe the relevant application, installation, and storage guidelines for Heradesign products.

Planning Service

Heradesign offers a special CAD planning service for the Heradesign® deluxe product. On one hand, this makes exact planning of the ceiling face possible. On the other hand, exact calculation of the order quantity is also possible. With this service, it is also possible to have special fitting pieces produced. You can obtain more detailed information from our technical customer service and at www.heradesign.at.

Distribution is handled via specialised trade.

Heradesign Ceilings Division A business unit of Knauf Insulation GmbH A – 9702 Ferndorf 29 Tel: +43/4245-2001 3332Fax: +43/4245-2001 [email protected]

The product data sheet presented here corresponds to the current state of development of our products and loses its validity when a new issue appears. Always make sure that you are using the latest issue of this information in each case. The suitability of the product is not binding for exceptional isolated cases. The guarantee and liability upon delivery are orientated around our general terms and conditions. No responsibility is assumed for the correctness of this information.

Datenblatt_Heradesign® deluxe 01.03.2008 (replaces version 01.02.2007)

Page 75: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

75

Veneers, 3-Layer Decorative Panels

Heradesign® deluxe

• 9 standard veneers can be chosen

• Other veneers are possible on request

• Grain: wire/half wire shifted

• The edge is designed with the same veneer as the surface

Fir

Birch

European ash

Maple

Beech

Pine

American walnut

European oak

Cherry wood

Page 76: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

76

Edges: 3-Layer Decorative Panels

Abbreviation Design Heradesign®

styleHeradesign®

deluxeSectionwidth

Griddimensions 1)

Paneldimensions

25 mm 25 mm mm mm mm

E-TP-01

Straight edge for visible T-section

24600x6001200x600

594x5941194x594

E-HP-01

Straight edge for top hat section, visible 33

614x600613x1200

600x6001200x600

E-HP-02

Grooved edge for top hat section, 1 mm panel joint 27

601x600601x1200

600x6001200x600

E-HP-03

Grooved edge for top hat section, 5 mm panel joint 27

605x600605x1200

600x6001200x600

Note:1) Grid sizes refer to the spacing of the top hat sections, or alternatively the Z-sections

ProductThickness

mmWeight kg/m2

Edge DesignGrid dimensions

mmPanel dimensions

mm

Heradesign® style 25 17.5E-HP-01E-HP-02E-HP-03

variabel600/600

1200/600

Heradesign® deluxe25 17.5

E-HP-01E-HP-02E-HP-03

variabel600/600

1200/600

Please note: Heradesign is not a system holder in terms of DIN-EN 13964

E-HP-O1 E-HP-O2 E-HP-O3

13

10 10

Page 77: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

77

Page 78: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

78

Page 79: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

79

2. Ceiling Constructions

Page 80: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

80

Installation with Top Hat Sections on CD Sections

ProductThickness

(mm)Weight kg/m2

Edge Design Grid dimensionsmm

Panel Dimensions mm

Heradesign® style 25 17.5E-HP-01E-HP-02E-HP-03

variable600/600

1200/600

Heradesign® deluxe25 17.5

E-HP-01E-HP-02E-HP-03

variable600/600

1200/600

Please note: Heradesign is not a system holder in terms of DIN-EN 13964

E-HP-O1 E-HP-O2 E-HP-O3

13

10 10

Page 81: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

81

Hanging system:Suckow & Fischer System 270 & 280

max

900 mm

max

750 mmmax1000 mm

max1200 mm

G

E

B

H

D

F

A

C

1

A

Assembly ComponentApprox. material

requirements*/m2 ceiling area for 600 mm panel width

Comments

A CD-60/27/0.7 main and load-bearing section

2.50 r.m. The distances in the drawing apply to loads up to 3 kp/m2 from a mineral wool lining.

B Longitudinal connector 0.70 pieces Stagger the section joints. An additional hanger must be placed beside each profile joint.

C Wall connecting shoe Consumption is dependant on floor plan

D Cross quick connector 1.40 pieces

E Top hat section 1.70 r.m. See below for profile types

F Wall angle section 0.30 – 0.60 r.m.Consumption is dependant on floor plan

G Z end section 0.30 – 0.60 r.m.

H Mounting screws 2.70 pieces Self-drilling screw 3.5/16 mm

1 Vernier hanger, complete 1 piece The distances in the drawing apply to loads up to 3 kp/m2 from a mineral wool lining.

• Observe information from manufacturer. The specified material values are non-binding guide values without cutting losses or other losses. Additional loads due to insulating material lining, lighting elements, wind, etc. must be borne separately.

E-HP-O1Profile No. DP 61

E-HP-O2Profile No. DP 59

E-HP-O3Profile No. DP 59

13

10 10

Page 82: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

82

Installation with Top Hat Sections on CD Sections Mounting Information:

For the design requirements, see DIN 18168 T.1 „Light-weight ceiling linings and suspended ceilings”.Mount the wall angle section and/or Z end section all around at the appropriate height taking into considerati-on the installation direction and edge design of the Hera-design decorative panels. Mount the CD basic section with vernier hanger. Spa-cing as in the drawing or according to static require-ments. Wall connection of the CD section by means of wall connecting shoe.Distribute the load-bearing sections symmetrically taking into consideration the required grid dimensions and an equal-sized edge field.Mount the first top hat section taking into consideration the placement pattern specified by the architect, starting in the centre of the room with self-drilling metal screws 3.5/16 mm. Insert or push-in the first panel and secure it with a sup-port.Mount the second top hat section. First, only secure it with screws in the area of the first panel.Install the other panels in this row by displacing the top hat section and sliding the panel in from the side. Screw the top hat sections one-by-one to the CD sections whi-le installing the panels.Film or mineral wool is inserted piece by piece along with the installation of the decorative panels. Film joints and connections must be masked off. A PE film with a thickness of up to 15 μm doesn’t degrade the sound absorption of the underlying absorber and is recommen-ded as trickle protection for mineral wool lining.The necessary corrosion protection of all metal elements that are used must be matched to the conditions prevai-ling in the room.Only use certified or standardised substructures.Damaged or soiled panels or panels with decoration flaws shouldn‘t be installed.Further instructions are analogous to fastening to CD metal sections.

••

Page 83: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

83

Insertion Installation in Visible T-Sections

Hanging systems:CMC 850, USG DX-24, DXB24, Profilvertrieb K 1100, Richter System 11.2, König T 24/38, Suckow & Fischer, System 200

Product Thickness(mm)

Weight kg/m2

Edge Design Grid dimensionsmm

Panel dimensionsmm

Heradesign® superfineHeradesign® fine

1515

7.38.0

SK-04SK-04

600/600625/625

594/594; 1194/594*619/619; 1244/619*

Heradesign® superfineHeradesign® fine

25, 3510.8/15.012.0/16.0

SK-04, SK-05,SK-06

600/600; 1200/600625/625; 1250/625

594/594; 1194/594619/619; 1244/619

Heradesign® plano 25 14.0 SK-04 600/600; 1200/600 594/594; 1194/594

Heradesign® micro 25, 35 14.5/18.5SK-04, SK-05,

SK-06600/600; 1200/600625/625; 1250/625

594/594; 1194/594619/619; 1244/619

Heradesign® fine/A2 25 17.5 SK-04 600/600; 1200/600 594/594; 1194/594

Heradesign® style 25 17.5 E-TP-01 600/600; 1200/600 594/594; 1194/594

Heradesign® deluxe 25 17.5 E-TP-01 600/600; 1200/600 594/594; 1194/594

* Large format not suitable for outdoor applications. For indoor applications up to max. stress class B as per EN 13964 Note: Max. span of the panels: 625 mm. Heradesign is not a system holder in terms of DIN-EN 13964.

1

2C

D

BA

E

Main section

spacinC

Hangerspacing

max.300 mm

am

aR

Page 84: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

84

System Max. Spacing 2) 3)

Material Requirements (without cutting losses or

other losses)

Loading level 1)

kN/m2

Griddimensions

(mm)

Main Section c(mm)

Hangers 4)

am (mm)

aR (mm)

Hangers 4)

Pieces/m2

0.8

600/600600/1200

1,2001,200300

0.70

625/625625/1250

1,2501,100300

0.73

0.12

600/600600/1200

1,2001,000250

0.80

625/625625/1250

1,250940250

0.85

0.15

600/600600/1200

1,200900250

0.90

625/625625/1250

6251,150250

1.40

0.2

600/600600/1200

6001,100200

1.50

625/625625/1250

6251,050200

1.50

0.25

600/600600/1200

6001,000200

1.70

625/625625/1250

625950200

1.65

1) The load level is comprised of the dead weight of the Heradesign panel, the weight of the absorber layer plus any wind suction forces that may have to be included in the calculation. Fittings such as ceiling lights, sprinkler systems, etc. must be hung separately. 2) Applicable to T 24/38 sections, material thickness at least 0.4 mm, as per DIN 18168, e.g. CMC 850 3) Sagging class 1 as per EN 1394. Observe manufacturer‘s information.4) Approved hanger load: at least 0.15 kN. Material requirements are dependent on the type of installation sys-tem. Observe manufacturer’s information. Max. distance aR of the first hanger from the wall £ 300 mm.

Please note: Max fee span width of the panels is 600 or alternatively 625 mm For F 30, EI 30 ceilings, only certified substructures may be used. The processing guidelines of the manufacturer must be observed. For certified ceiling structures, no changes may be made to the design compared to the certified construction.

Maximum spacing of the substructure and hanger material requirements

Maximum section and hanger spacing for sagging class 1 as per EN 13964 (max. sagging L/500 4 mm)

Page 85: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

85

Assembly

Component

Approx. material requirements / m2 ceiling area 1)

Comments600/600 1200/600 625/625 1250/625

A Main section 2)

T24/38r.m. 0.85

1.700.851.70

0.81.60

0.801.60

Spacing:1200/1250 mm 600/625 mm

B Cross section 3)

T24/38r.m. 2.50

1.701.700.85

2.401.60

1.600.80

L=600; 625; L=1200; 1250 mm

C Wall angle section

r.m. 0.40 0.4 0.4 0.4 Requirements are dependent on floor plan

D Panelclamps 4)

approx.units

6 3 6 3 Only for panel thickness of 15 mm

E Wall spring approx.units

0.8 0.4 0.8 0.4 Requirements are dependent on floor plan

1) The material requirements are dependent on the installation system. Observe information from manufacturer.The specified values are non-binding guide values without cutting losses or other losses.

2) Stagger the section joints; place an additional hanger beside each joint.3) Cross section may not lie on the lower flange of the main section.

Only use cross sections with a disengaged lower flange.4) Panel clamps are recommended to hold down the panels if high wind pressure loads can occur. Attention:

Limited access possibility to the ceiling cavity.

Please note:Special corrosion protection is needed for all metallic parts in swimming pools, outdoor applications, or applicati-ons with increased risk of corrosion.For F 30, EI 30 ceilings, only certified substructures may be used.Ceiling structures as per certificate: No changes may be made to the design compared to the certified construction.

Minimum hanger heights:In order to be able to insert the panels in preinstalled hanging systems, the following minimum hanger heights (AH = lower edge of T-section to lower edge of rough surface) must be maintained.

Panel thickness 15 mm min. AH 100 mmPanel thickness 25 mm min. AH 125 mmPanel thickness 35 mm min. AH 150 mm

Suspended Ceilings with Visible T-Sections

Page 86: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

86

1 Heradesign decorative panel, 25 or 35 mm2 T-24/38 section3 Contact angle 24 x 24 x 0.5 mm, screws 6 x 50 in metal expansion plugs4 Heralan DP-5 lining, 2 x 50 mm. Alternative: Heralan DP-4 lining, 2 x 60 mm.5 Quick hangers with tension spring or vernier hangers

Ceiling in a F 30 design with Heradesign® fine or Heradesign® micro decorative panelsThickness 25 or 35 mm, insertion installation into visible T24 sections. Certificate: ABP 3413/9499-MPA BS Test institute: iBMB Braunschweig

Detail 1

Detail 2

1

2

4

4

5

3

Ceiling in an EI 30 design with Heradesign® superfine decorative panelsThickness 25 mm, insertion installation in visible T24 sectionsCertificates: MA 39 VFA 2004-1945.02Test Institute: MA 39, Test and Research Institute of the City of Vienna

1 Heradesign decorative panel, 25 or 35 mm2 T-24/38 section3 Contact angle 24 x 24 mm Screws 6 x 50 in metal expansion plugs5 Heralan DP-5 lining, 2 x 50 mm6 Quick hangers with tension spring or vernier hangers

1

2

4

4

5

3

Page 87: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

87

Short Hangers

Type 21.1 AH = 100 CMC-Clips

Type 21.5 AH = 50 mm CMC-Clipsonly for 15/25 mm panel thickness

AH = hanger height

Type 21.8 AH = 80 mm CMC-Clips

Type 21 AH = 89 CMC-Clips

Attention: For these installation heights, the panels must slide in from the side using T-sections. The hanging system and the panels can only be installed field by field. There is an increased installation effort!

AH

AH

Type Height Max. Load

21 AH = 89 mm

45 kg21.5 AH = 50 mm

21.8 AH = 80 mm

21.1 AH = 100 mm

Page 88: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

88

Mounting Information:

• For the implementation requirements, also see DIN 18168 T.1 „Lightweight ceiling linings and suspended ceilings”, or alternatively DIN-EN 13964 “Suspended ceilings - require-ments and test methods”.

• Mount the wall angle section C at the desired height.

• Distribute the main load-bearing axes while observing equal border fields.

• Mount the quick hangers with tension springs 1 or sliders 2; hang and adjust the main section A.

• Stagger and place the track joints and hangers; 1 addition hanger must be placed beside each joint.

• Put the cross sections B together with the main section A for each field, taking equally sized end fields into consideration.

• Insert the Heradesign decorative panels field by field starting in the centre of the roomand then moving out.

• Insert the edge panels into the wall angle profiles with 10 mm of airspace and fasten with wall springs E.

• 15 mm thick panels must be fastened with panel clamps.

• Please note: For suspended ceilings that are subject to swaying and for large suspensi-on heights, or where the hangers are fastened to steel or wood structures, an adequate number of hangers must be set diagonally in both directions in order to minimise the swaying of the ceiling. Ceiling statics are necessary.

• For F 30/ EI 30 constructions: Only use approved hanging systems.

• Mineral wool is inserted piece by piece along with the installation of the acoustic panels.

• The corrosion protection must be matched to the conditions prevailing in the room.

• Damaged or soiled panels or panels with colour deviations shouldn‘t be installed.

Page 89: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

89

Construction of ceiling grid while observing equal size end fields. Stagger the section joints. An additional hanger must be placed beside each joint.

Lift the Heradesign decorative panels by tilting the panes and using the ceiling cavity. Observe the minimum han-ging heights.

Press down the Heradesign decorative panel. The panels are cut exactly to size; therefore they have to be pressed past the hangers.

Install Heralan acoustic lining piece by piece along with the Heradesign decorative panels.

Installation Photos

Use a knife to cut out the mounting slot for hangers in Heralan acoustic lining.

Only use cross sections with a disengaged lower flange.

Page 90: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

90

Suspended Ceiling – Concealed T-Section/Push-in Mounting

A

B

C

DE

1

2

Assembly Component

Load-bearing section

Spacer

Wall angle section

Cross sectionWall spring

Quick hangersloadable up to 25 kg

alternative to 1:Slider with slotted

metal strap

1.7

0.7

0.4

0.850.4

1.35

1.50

1.6

0.7

0.4

1.60.8

1.30

1.45

r.m.

r.m.

r.m.

r.m.r.m.

pcs.

Approx. material requirements/m2 ceiling area*

600/600 1200/600 625/625 1250/625

1.6

0.7

0.4

0.80.4

1.30

1.45

L = 3615 mm, profile width: 35 mm

L = 600; 625; Profile width: 35 mm

Requirements are dependent on floor planL = 600; 625;

Requirements are dependent on floor plan

** 1230 mm bis 14.5 kg/m2

** 1150 mm bis 18.5 kg/m2

Comments

1.7

1.7

0.4

0.70.8

1.35

1.50

1C

E

2

AB

D Hanging system:CMC 650USG DX-T35

* Observe information from manufacturer! The specified values are non-binding guide values without cutting losses or other losses.Additional loads due to insulating material lining, lighting, etc. must be borne separately. ** max. spacing dependent on panel weight

Please note: Cross bracing: If the cross section is not anchored in the main section (straight T-joint), the cross bracing of the system

must use spacers (see drawing above, No. B). The positioning is such that a spacer is placed above every second panel and the maximum spacing is 1250 mm.

Access to the ceiling cavity: The ceiling cavity can be accessed through panels with integrated maintenance openings.For each maintenance opening, place an additional hanger for each of the two load-bearing sections around the centre of the panel.

Max. span of the panels: 625 mm.

Custom formats only on request, max. length 1800 mm.

Heradesign is not a system holder in terms of DIN-EN 13964.

max. 600 mm

max. 625 mm

Page 91: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

91

Heradesign® superfineHeradesign® fineHeradesign® microHeradesign® planoHeradesign® fine/A2

Product

25, 3525, 3525, 35

2525

Thickness (mm)

VK-09

Edge Design

600; 625

600

Grid dimensions (mm)

600/600

600/600; 625/6251200/600; 1250/625

Panel Dimensions (mm)

Page 92: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

92

Mounting Information:

For the design requirements, see DIN 18168 T.1„Lightweight ceiling linings and suspended ceilings”. Mount the wall angle section C at the desired height. Distribute according to the grid dimensions taking equal border fields into consideration.Mount the quick hangers 1 or alternatively stagger the sliders with the slotted metal straps 2 and hang load-bearing sections A. Adjust the load-bearing sectionsStagger and place the track joints and hangers; one additional hanger must be placed beside each joint.Insert the Heradesign decorative panels field by field starting in the centre of the room and moving out. The load-bearing sections must be pushed apart to insert the panels.Cross bracing by means of spacers B and cross sec-tions D Insert the edge panels into the wall angle profiles with 10 mm of airspace and fasten with wall springs E. For ceilings that are safe against ball throwing, the edge panels must be additionally secured against lifting where they meet the wall.Please note: For suspended ceilings that are subject to swaying and for large suspension heights, or where the hangers are fastened to steel or wood structures, an adequate number of hangers must be set diagonally in both directions in order to minimise the swaying of the ceiling. Ceiling statics are necessary.Film or mineral wool is inserted piece by piece along with the installation of the decorative panels. Film joints and connections must be masked off. A PE film with a thickness of up to 15 μm doesn’t degrade the sound absorption of the underlying absorber and is recom-mended as trickle protection for mineral wool lining. The corrosion protection must be matched to the con-ditions prevailing in the room.Damaged or soiled panels or panels with colour devia-tions shouldn‘t be installed.

Page 93: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

93

Suspended Ceiling –

Concealed T-Section/Panels can be Disassembled

Heradesign® superfineHerakustik® fineHerakustik® micro

Product

353535

Thickness (mm)

VK-10

Edge Design

600

Grid dimensions (mm)

615/600615/1200

Panel Dimensions (mm)

Minimum hanger height: To make perfect installation of the panels possible, the hanger height must be at least the following (bottom edge of T-section to upper edge of load-bearing ceiling). For a mineral wool lining, the hanging height must be increased by the thickness of the mineral wool.

Product Panel thickness mm

Hanger(see drawing above for models)

Minimum hanging heightmm

Heradesign® superfineHeradesign® fineHeradesign® micro

35

Hanging wire with hooks 140

Hanging with sliders 140

Flat hangers 190

Please note: Heradesign is not a system holder in terms of DIN EN 13964 Custom lengths on request - max. panel length 1800 mm Max. span of the panels: 625 mm

Page 94: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

94

ABCD

1

2

Assembly Component

Load-bearing sectionSpacer

Wall angle sectionWall spring

Quick hangersloadable up to 25 kg

alternative to 1:Slider with slotted metal strap

1.70.70.40.4

1.35

1.45

r.m.r.m.r.m.pcs.

pcs.

ca. Material requirements/m2

ceiling area600/600 1200/600

L = 3615 mm, profile width: 35 mmL = 600 mm, max. spacing 1200 mm

Requirements are dependent on floor planRequirements are dependent on floor plan

** 1230 mm up to 14.5 kg/m2

** 1150 mm up to 18.5 kg/m2

Anmerkung

1.70.70.40.8

1.35

1.45

max

. 600

mm

A

B

D

C

21

Hanging systems: CMC 650USG DX-T35

* Observe information from manufacturer! The specified values are non-binding guide values without cutting losses or other losses.Additional loads due to insulating material lining, lighting, wind, etc. must be borne separately.

** max. spacing dependent on panel weight

Please note:Cross bracing: Since no cross sections can be placed between the main sections, spacers must be used for cross-bracing the system (see drawing above, No. B). The positioning is such that a spacer is placed above every second panel and the maximum spacing is 1250 mm. Hence, every second panel can be dismantled immediately.

Access to the ceiling cavity: Every second panel can be dismantled. Test to find out which end of the panel is free. Push the panel up here and lift it diagonally out of the track grid. For larger access openings, remove the spacers from the neighbouring panels and remove the panels. When inserting the ceiling panels, replace the removed spacers without exception.

Page 95: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

95

Mounting Information:

For the design requirements, see DIN 18168 T.1 „Lightweight ceiling linings and suspended ceilings”. Mount the wall angle section C at the desired height. Distribute according to the grid dimensions taking equal border fields into consideration.Mount the rapid hangers 1 or alternatively the sliders with the slotted metal straps 2 and hang weight-bearing profiles A. Adjust the load-bearing sections.Stagger and place the track joints and hangers; one additional hanger must be placed beside each joint.Fit in the Heradesign decorative panels field by field starting in the centre of the room and moving out. Cross bracing by means of attaching spacers B.Insert the edge panels into the wall angle profiles with 10 mm of airspace and fasten with wall springs E. If a mineral wool lining is necessary, this can only be done in the shape of the panels and must be placed such that it can be lifted with the decorative panel so that the ceiling cavity can be accessed. Please note: For suspended ceilings that are subject to swaying and for large suspension heights, or where the hangers are fastened to steel or wood structures, an adequate number of hangers must be set diagonally in both directions in order to minimise the swaying of the ceiling. Ceiling statics are necessary.The corrosion protection must be matched to the con-ditions prevailing in the room.Damaged or soiled panels or panels with colour devia-tions shouldn‘t be installed.

Page 96: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

96

Suspended Ceiling – Visible Omega Section

1

2

C

DB

A

E

F

Centre distance 1500 mm

L = 4000 mmL = 3050 mm, requirement is

dependent on floor plan

Number dependent on panel weight max. spacing 930 mm up to 12.0 kg/m2

max. spacing 620 mm up to 18.5 kg/m2

Nr. 1352-31-00L = 3870 mm

0.71.60.4

0.20.42.2

0.7

1.05

Nr. 1325-30-00L = 3720 mm

0.71.70.4

0.20.42.2

0.75

1.10

Type

r.m.r.m.

approx.r.m.pcs.pcs.pcs.

pcs.

Load-bearing section

Omega sectionWall angle section

Load-bearing section connectorOmega section connectorScrew and nut M 5 x 12

Quick hangers with tension spring,

loadable 25 kgalternative to 1

Quick hangers with anchoring

A

BC

DEF

1

2

Assembly Component ca. Material requirements*/m2

ceiling area620 645

Comments

* Observe information from manufacturer! The specified values are non-binding guide values without cutting losses or other losses. Additional loads due to insulating material lining, lighting, etc. must be borne separately.

Hanging system:CMC 1350

Please note: Max. span of the panels is 625 mmHeradesign is not a system holder in terms of DIN-EN 13964

Page 97: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

97

Mounting Information:

For the design requirements, see DIN 18168 T.1 „Lightweight ceiling linings and suspended ceilings”. Mount the wall angle section C at the desired height.Distribute according to the grid dimensions taking equal border fields into consideration.Install the load-bearing sections A by using quick han-gers 1 or 2 and load-bearing section connectors D.An additional hanger must be placed beside each joint.Please note: For suspended ceilings that are subject to swaying and for large suspension heights, or where the hangers are fastened to steel or wood structures, an adequate number of hangers must be set diagonally in both directions in order to minimise the swaying of the ceiling. Ceiling statics are necessary.Fasten omega section B in the modular grid to load-bearing section A by means of screw and nut. Put in the Heradesign acoustic panels- square format joint-to-joint- longitudinal format joint-to-joint or in the bondInsert the edge panels into the wall angle section C with approx. 10 mm gap and fasten with wall springs.Film or mineral wool is inserted piece by piece along with the installation of the acoustic panels. The corrosion protection must be matched to the con-ditions prevailing in the room.Damaged or soiled panels or panels with colour devia-tions shouldn‘t be installed.

Page 98: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

98

Heradesign® superfineHeradesign® fineHeradesign® micro

SK-08SK-08 SK-08

620; 645 595/600; 620/625595/1200; 620/1250

25, 3525, 3525, 35

Product Edge Design

Grid dimensionsThickness (mm)

Panel Dimensions (mm)

Page 99: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

99

Installation with Heradesign retaining claws

Heradesign® superfineHeradesign® fineHeradesign® microHeradesign® planoHeradesign® fine/A2

SY-02SY-02SY-02SY-02SY-02

600; 625600; 625600; 625

600600

600/600; 1200/600625/625; 1250/625

600/600; 1200/600

25, 3525, 3525, 35

2525

Product Edge Design Centre Distance of the LathThickness (mm) Panel Dimensions (mm)

Claw pattern:

Bottom row of panels

Please note: Heradesign is not a system holder in terms of DIN-EN

A

B

C

D

A

Page 100: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

100

Heradesign Retaining Claw Rust-protected assembly section for concealed fastening of Heradesign decorative panels.

Area of application: as an invisible ceiling, wall, and pitched roof section Not suitable for indoor swim-ming pools and humid rooms.

Design: edged, pre-galvanised slit strips 1mm, drill hole 5mm

Installation: approx. 3 retaining claws for each m2,each with 4 screws min 4.5/25

600/600 1200/600 625/625 1250/625

* Observe information from manufacturer. The specified values are non-binding guide values without cutting losses or other losses. Additional loads due to insulating material lining, lighting, etc. must be borne separately.

A

B

C

D

Assembly Component

Wood lath

Screw + dowel for fastening the

cross joist

Standard section

End section

1.7

1.7

2.8

1.6

1.6

2.6

r.m.

pcs.

pcs.

pcs.

Min. material requirements*/m2 ceiling area

1.6

1.6

2.6

Wood cross-section: 30 x 80 mm; 30 x 60 mm

Maximum spacing 1000 mm up to 14.5 kg/m2

loading or according to statics requirements.

Max. free span of the panel: 625 mm. Min. 3 screws per

clampConsumption is dependant

on floor plan

Comments

1.7

1.7

2.8

0.2 – 0.4

Installation of Maintenance OpeningsIt is only possible to install maintenance openings with dimensions 400 x 600 in panels with the for-mat 1200 x 600 mm or alternatively 1250 x 625 mm parallel to the tracks.

Material Requirements

Page 101: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

101

Mounting Information:

1) Installation of the wood laths against the under-ground with certified dowels and screws accor-ding to static requirements. The centre distance of the tracks is that same as the panel width. Recommended wood cross-section: approx. 80 x 30 mm. Every 600 mm or alternatively 625 mm, place an end claw with 4 screws of the size 4.5/25. It is important to accurately align the positioning claws (claws only on one side) so that any impreci-sion is not passed on the other rows of panels.

For the implementation requirements, also see DIN 18168 T.1 „Lightweight ceiling linings and counter ceilings”.

2) Start installing the panels from the centre of the area so that there will be the same size panels on both ends. To do this, mark the centre of the area with a reference line and install the first row of panels to the left and right of this line.

3) Check to make sure the panel edges are aligned for each row that is installed.

4) During installation, align all panels according to the reference line.

5) Claw schema for rectangular panel format: 1200 x 600 mm or 1250 x 625 mm. Use at least 2 claws per panel, or alternatively 3 claws per m2.

6) Claw schema for square panel format: 600 x 600 mm or 625 x 625 mm. Consumption: at least 1 screws. per panel, or 3 claws per m2*)*) The actual consumption is dependent on the type of installation.

Page 102: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

102

7) Fasten the Heradesign retaining claws with 4 corrosion protected screws of the size 4.5/25.

8) Always fasten the panel corners with a retaining claw. The end panels of each row must be secured against shifting. This can be done with a screw or an additional, transversely mounted end section. If end claws are used, then they must be covered with a blind.

9) Lifting in the panels. For square panels, pay attention to the installation direction. This is marked on the back of the panel. Attention: When installing the panels on the ceiling, the panels must not be allowed to hang with a free overhang. The panels must be supported until installation of the second row of retaining claws.

10) For square installation grids (cross joint joints), make sure that all four panel edges are on the same point. Another criterion is the panel’s prefer-red direction, which is of major importance to the appearance of the ceiling/wall.

11) The end row is fastened either with end sec-tions or with screws of the size 4.5 / length.

12) For screws in the end zone: Cover the screw heads with the same colour that is used for colou-ring the panels.

Page 103: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

103

Fastening onto Wood Laths

Product Thicknessmm

Weight kg/m2

Edge Design Centre Distance of the Lath

Panel Dimensi-ons mm

Heradesign® superfine 15 7.3 AK-01 300; 312.5 1)

600/6001200/600625/6251250/625

Heradesign® fine 15 8.0 AK-01 300; 312.5 1)

Heradesign® superfine 2) 25, 35 10.8 / 15.0 AK-01, AK-02, AK-03

600; 625

Heradesign® fine 2) 25, 35 12.0 / 16.0 AK-01, AK-02, AK-03

600; 625

Heradesign® micro 25, 35 14.5 / 18.5 AK-01, AK-02, AK-03

600; 625

Heradesign® superfine 35 15.0 VK-12 590; 615Heradesign® fine 35 16.0 VK-12 590; 615Heradesign® micro 35 18.5 VK-12 590; 615Heradesign® fine/A2 25 17.5 AK-01 600 1200/600;

600/600Heradesign® industry 25 9.7 AK-01 600 2400/600Heradesign® superfine25 mm/MW

100, 125 17.419.6

AK-01 600

1200/600Heradesign® fine25 mm/MW

100, 125 18.521.0

AK-01 600

Heradesign® micro25 mm/MW

100, 125 21.023.0

AK-01 600

1) For panel dimensions 1200/600 and 1250/625, a centre distance of the lath of 1/3 the panel length is permitted as an alternative.2) Please note: Edge design GK – straight edge without bevel, for screw installation on wood laths, only carry this out with shadow gaps of 4 mm between the panels. Increased care is necessary during installation. Pay attention to the changed grid dimensions!

Please note: Heradesign is not a system holder in terms of DIN-EN 13964

Main joist spacing

max 600 bzw. 625 mm

max 125 mm

ca. 190 mm

ca. 190 mm

a

b cCross joist

Hanger centre distance

Page 104: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

104

Main joistsCross-section: w/h

60/30 mm 60/40 mm

Cross joistmax. distance b

600 or 625 mm

Load Classes(Dead weight of the suspended ceiling in kN/m2)

Maximum centre distance c

Cross-section b/h 0.15 kN/m2 0.20 kN/m2 0.30 kN/m2

Permissible additional load *) in kN/m2

for hanger spacing a (m)

C = 600 mm

60/300.30 kN/m2

a=1.15 m0.35 kN/m2

a=0.90 m0.35 kN/m2

a=0.75 m

48/24 **0.30 kN/m2

a=1.15 m0.35 kN/m2

a=0.90 m0.35 kN/m2

a=0.75 m

C = 800 mm

60/300.30 kN/m2

a=1.05 m0.35 kN/m2

a=0.80 m

48/24 **0.20 kN/m2

a=1.05 m0.25 kN/m2

a=0.80 m

C =1000 mm60/30

0.30 kN/m2

a=0.95 m

48/24 ** –

C = 1200 mm60/30

0.30 kN/m2

a=0.90 m

48/24 ** –

*) Additional load: Applied load from mineral wool lining, suction load from wind etc. Fittings such as ceiling lights, sprinklers, etc. must be hung separately. **) for cross joists 48/24, the cross-section of the main joists must be 60/40 mm.

Max. hanger load: 0.40 kN. With an additional hanger load of 0.25 kN, the additional loads must be multiplied by 0.6, i.e. reduced. Wood quality class S 10 as per EN 1912. For F 30, EI 30 ceilings, or alternatively ceilings that are safe against ball throwing, the spacing and cross-sections must be according to the test certificate.

Detail AConnection main lath / bearing lath

Hanger

Fastening of cross joist to main joist 60/30 or 48/24 with screws 4.5 x 55 mm as per DIN 7997. Thread engagement min. 25 mm. Number of screws according to static requirements, recommendation: 2 screws per junction point. As per DIN 18168, however, a single screw is also permitted here. ( 5 x 55 mm)

Cert. load f = 0.15 kN

Cert. load f = 0.40 kN

Maximum spacing of the substructurefor sagging class 1 as per EN 13964 (max. sagging L/500 4 mm)

30 mm

24 mm

Page 105: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

105

Design that is safe against ball throwing according to DIN 18032/Part 3:

Please note: Fitting pieces with lengths that are less than 500 mm must be supported on all 4 sides.

Screw pattern: To fasten Heradesign decorative panels in a way that is safe against ball throwing, at least 3 screws must be used per panel width and support. Max. spacing of the screws 315 mm.

600

max

625

mm

When installing maintenance openings with dimensions of 400 x 400 mm or alternatively 400 x 600 mm in panels with formats of 1200 x 600 or alternatively 1250 x 625, the middle lath must be recessed for a length

of 500 mm so that it is possible to access the ceiling cavity. Pay attention to the additional anchoring for the free ends of the laths.

Installation of Maintenance Openings

Product Thickness

(mm)

Edge

Design

Centre Distance of

the Lath

Dimensioning of

the laths in mm

Panel Dimen-

sions (mm)

Heradesign® superfine 35 AK-01 600

60 x 30

1200/600

Heradesign® fine 35 AK-01 600; 625 1200/600

Heradesign® micro 35 AK-01 600; 625 1250/625

Sports halls:If Heradesign decorative panels are used as a wall covering behind football or handball goals, basket ball baskets, or alternatively behind the baseline in tennis courts, we recommend using an impact net in the affec-ted areas. Heradesign decorative panels are not suitab-le as an “impact wall”.

Protective function requirements: Walls may only be covered with Heradesign decorative panels as of a height of 2 metres. Heradesign decorative panels are not considered to be an “impact reducing material”, which means they don’t meet the protective function requirements for wall coverings in the contact zone of persons.

Page 106: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

106

Standard Screw Schematic for Heradesign Decorative Panels

Format: 625 x 625 mm and 625 x 1250 mm or. 600 x 600 mm and 600 x 1200 mm

Please note: For installation of the panels that is safe against ball throwing: at least 3 screws per panel width and support

for panel thickness of 15 mm

Comment:In rooms with constantly high humidity, screws with adequate corrosion protection must be used.

for panel thickness of 25 and 35 mm

Minimum cross-section according to DIN 18168 or EN 13964: 60 x 40 mm or at least 50/30 mm, if main and cross joists have the same cross-section.

Cross joists and edge distances

Cross joists 60/30 mm or alternatively 80/24; recommended lath width: 80 mm Minimum cross-section: 48 x 24 mm for main joist 60 x 40 mm

6 screws/panel 4 screws/panel

6 screws/panel8 screws/panel

600

625

400

417

400

416

400

417

600

625

600

625

*) For F 30 ceilings as per DIN 4102: Screw in Heradesign screws at an angle of approx. 10º or use shims. Attention: After complete assembly, screw heads are to be covered with paint.

Heradesign decorative panel

Cross joist

60 x 30 mm

Heradesign decorative panel

Screw

60 mm

Laths

Edge of panel

20mm

20m

m

60 mm

*)

60 mm

40 m

m

Main joists

Width

Page 107: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

107

F 30 Ceiling with Heradesign® fine,Heradesign® micro decorative panels

EI 30 Ceiling with Heradesign® fine decorative panels

1 Heradesign® fine, 25 mmEdge AK-01, AK-02, AK-03

2 Heradesign screw 4.5 x 50 mm,3 screws per panel width3 Wood lath 80 x 50 mm4 Knauf GKF- A2 panel, 15 mm5 Knauf TN 3.5 x 35 mm screw6 Heralan DP-5 rock wool, thickness 50 mm

Detail B2, B3

Thickness 25, or 35 mm, screwed to wood laths 60x40 mm Certificate: ABP -3413/9499-MPA BS Test institute: iBMB Braunschweig

1 Heradesign decorative panel, 25 or 35 mm

2 Drywall screw 4.5 x 50 mm,3 screws per panel width, set skew3 Wood lath 60 x 40 mm4 Heralan DP-5 rock wool, thickness 80 mm

Detail B1

12

3 4

12

4

3 6

5

Thickness 25 mm, screwed to wood laths 80 x 50 mmEdge connection with drywall frieze or butt–jointedCertificate: MA 39 - VFA 2005-0549.01 Test institute: MA 39, Test and Research Institute of the City of Vienna

EI 30 Ceiling with Heradesign® fine/A2 panels

Thickness 25 mm, screwed to wood laths 80 x 40 mmEdge connection with drywall frieze or butt–jointedCertificate: MA 39 - VFA 2005-056701 Test institute: MA 39, Test and Research Institute of the City of Vienna

1 Heradesign® fine/A2, thickness 25 mm2 Heradesign screw 4.5 x 50 mm,3 screws per panel width3 Wood lath 80 x 40 mm4 Knauf GKF- A2 panel, 15 mm5 Knauf TN 3.5 x 35 mm screw6 Heralan DP-5 rock wool, thickness 40 mm

Detail B4, B5

12

4

6

5

Page 108: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

108

Installation Photos

Applying the ceiling grid from the centre of the room, e.g. by using a chalk line. Pay attention to having equal sized edge fields at the sides of the room.

Installation of the main joists and cross joists.

Aligning the laths with a spirit level or laser level. Insertion of Heralan absorber panels one by one along with the instal-lation of the Heradesign decorative panels. Panels that get jammed between the wood laths are cut to size.

Alternative: Insertion of PE sheeting as trickle protection or a vapour barrier matching the installation of the Heradesign decorative panels. Stick sheet joints together.

Installing the panels by means of supports. Press the panel onto the lath with the ball of the hand while screwing. There mustn’t be a gap between the panel and the wood lath. Only work with the panels with clean hands and a clean tool.

Align the panel rows with an installation lath. Panel joints must be positioned to be centred under the section. No free panel joints are allowed.

Paint over the screw heads with the supplied paint or an equivalent one. The screw heads must be flush with the surface of the panel.

Page 109: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

109

Rust protected, universal dry-wall screw for attaching Heradesign decorative panels to laths and CD sections. Partial thread, screw head with Torx T20Requirements: depending on the width of the panel and the centre distance, at least 2 screws; version that is safe against ball throwing at least 3 screws. Minimum spacing: 600 or 300 mm

625 or 312 mm

Please note:Not suitable for indoor swimming pools and outdoor applications.

Mounting Information:

For the implementation requirements, also see DIN 18168 T.1 „Lightweight ceiling linings and suspended ceilings”, or alternatively DIN-EN 13964 “Suspended cei-lings - requirements and test methods”.Fasten wood laths to the ceiling at the required centre distance with rust-protected screws.

Distribute laths symmetrically (equal border fields)

Start panel installation from the centre of the room.Press the panels in and align them longitudinally in the bracing, transversely to the direction of the laths and fasten them with rust-protected dry-wall screws (head diameter 9 mm) to the laths. For each panel width and centre distance, 2 dry-wall screws (DIN 7997) are required. For 15 mm thick panels, or alternatively for the version that is safe against ball throwing, 3 screws are required. - Square panels: Observe the installation direction mar-ked on the back when installing the panels.Cross joints: 4 panel corners meet at one point, which means increased accuracy is required when installing. For F 30 constructions as per DIN: Set the screws skew at an angle of 10 degrees or use washers.Screws: Wood or dry-wall screws with partial thread and countersunk heads are suitable. Head diameter 9 mm. The necessary corrosion protection must be matched to

the conditions prevailing in the room. The screw heads must be set to be flush with the panel surface and after installation, they must be covered with a paint supplied by the manufacturer or an equivalent.Film or mineral wool is inserted piece by piece with the installation of the acoustic panels. Film joints and con-nections must be masked off. A PE film with a thickness of up to 15 μm doesn’t degrade the sound absorption of the underlying absorber and is recommended as trickle protection for mineral wool lining.Damaged or soiled panels or panels with colour deviati-ons shouldn‘t be installed.

Corrosion protection: To find suitable corrosion pro-tection for screws for applications in swimming pools, underground garages, sheltered outdoor applications or other special applications, please contact your screw supplier or alternatively screw manufacturer.Schraubenproduzenten ab.

Heradesign Screws

Dimensions mm For panel thickness mm

Packaging units pieces/boxLength Ø

50 4.5 25 200

60 4.5 35 200

Panel thickness (mm) 15 25 35 100 125

Screw dimensions, Heradesign screws (mm) 4.5/30 4.5/50 4.5/60 – –

Screw dimensions according to DIN 7997, ÖNORM M5027 (mm)

4.5/35 4.5/45 4.5/60 L 140 L 160

Page 110: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

110

Fastening onto CD Metal Sections

1) For panel dimensions 1200/600 and 1250/625, a centre distance of the lath of 1/3 the panel length is permitted as an alternative.2) Please note: Edge design GK – straight edge without bevel, for screw installation on wood laths, only carry this out with shadow gaps of 4 mm between the panels. Increased care is necessary during installation. Pay attention to the changed grid dimensions!

Please note: Heradesign is not a system holder in terms of DIN-EN 13964

Hanging system: Profile sales K 400Richter D112Fa. König

Product Thicknessmm

Weight kg/m2

EdgeDesign

Centre Distance of Section

Panel Dimensi-ons mm

Heradesign® superfine 15 7.3 AK-01 300; 312.5 1)

600/6001200/600625/6251250/625

Heradesign® fine 15 8.0 AK-01 300; 312.5 1)

Heradesign® superfine 2) 25, 35 10.8 / 15.0 AK-01, AK-02, AK-03

600; 625

Heradesign® fine 2) 25, 35 12.0 / 16.0 AK-01, AK-02, AK-03

600; 625

Heradesign® micro 25, 35 14.5 / 18.5 AK-01, AK-02, AK-03

600; 625

Heradesign® superfine 35 15.0 VK-12 590; 615

Heradesign® fine 35 16.0 VK-12 590; 615

Heradesign® micro 35 18.5 VK-12 590; 615

Heradesign® fine/A2 25 17.5 AK-01 600 1200/600600/600

Heradesign® industry 25 9.7 AK-01 600 2400/600

Heradesign® superfine25 mm/MW

100, 125 17.419.6

AK-01 600

1200/600Heradesign® fine25 mm/MW

100, 125 18.521.0

AK-01 600

Heradesign® micro25 mm/MW

100, 125 21.023.0

AK-01 600

B

F

E

A

D

C

A

CR

CmBasic Profile

am

aR

max. 600 bzw.

625 mm

Page 111: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

111

Basic Profile 60/27/0.6 mm

Load Classes(Dead weight of the suspended ceiling in kN/m2)

Max. centre distance C (mm)0,15 kN/m2 0,20 kN/m2 0,30 kN/m2

Permissible additional load ZL*) in kN/m2 for hanger spacing a (m)

cm = 600 mm (middle field)cR = 600 mm (edge field)

ZL=0,20 kN/m2

am = 1.15maR=1.00 m

ZL=0.40 kN/m2

am = 0.90maR=0.75 m

ZL=0.50 kN/m2

am = 0.75maR=0.60 m

cm = 800 mm (middle field)cR = 680 mm (edge field)

ZL=0,20 kN/m2

am = 1.05maR=0.90 m

ZL=0.35 kN/m2

am = 0.80maR=0.70 m

ZL=0.35 kN/m2

am = 0.70maR=0.60 m

cm = 1000 mm (middle field)cR = 850 mm (edge field)

ZL=0.20 kN/m2

am = 0.95maR=0.80 m

ZL=0.20 kN/m2

am = 0.75maR=0.60 m

cm = 1200 mm (middle field)cR = 1000 mm (edge field)

ZL=0.10 kN/m2

am = 0.90maR=0.75 m

*) Additional load: Load from mineral wool lining, suction load from wind etc. Fittings such as ceiling lights, sprinklers, etc. must be hung separately. The max. spacing of the load-bearing sections 60/27/0.6 is 600 mm or alternatively 625 mm. For the edge fields of load-bearing sections, the shorter spacing applies (cR, aR ). am = spacing of the hangers in the field. aR = edge distance of the hangers to the wall. Max. hanger load: 0.40 kN. With an additional hanger load of 0.25 kN, the additional loads must be multiplied by 0.5, i.e. reduced. For F 30, EI 30 ceilings, or alternatively ceilings that are safe against ball throwing, the spacing and cross-sections must be according to the test certificate. See the details of the F 30 – EI 30 designs.

Spacing, Mounting on CD-Sections Maximum section and hanger spacing for sagging class 1 as per EN 13964 (max. sagging L/500 4 mm)

Detail A1Alternative: Edge connection with U-section

CD basic section 60/27/0.6CD load-bearing section 60/27/0.6Heradesign panelAlways position panel joint in supporting direction under a CD section

AssemblyComponent

Approx. Material requirements / m2 ceiling area*Comments

600/600 1200/600 625/625 1250/625

A CD-basicsection

60/27/0,6

r.m. 0.91.1

0.91.1

0.91.1

0.91.1

Spacing 1000 mm Spacing 800 mm

B CD load-bearingsection

60/27/0.6

r.m. 1.7 1.7 1.6 1.6 Spacing in panel widths

C E wall connection

section

r.m. 0.4 - 0.8 0.4 - 0.8 0.4 - 0.8 0.4 - 0.8 Consumption is dependant on floor plan

D CDconnector

pcs. 0.60.7

0.60.7

0.60.7

Stagger the section joints!

E CD cross connector

pcs. 1.7 1.7 1.7 1.7

F CD vernier hanger

pcs. 1.21.5

1.21.5

1.21.5

1.21.5

Dependent on spacing of the basic section

** Observe information from manufacturer! The specified values are non-binding guide values without cutting losses or other losses. Additional loads due to insulating material lining, lighting, wind, etc. must be borne separately.

Material Requirements

Please note: In the event of increased requirements on fire protection F30 / EI30 or sound protection, a gypsum board can be put between the substructure and the Heradesign acoustic panels. Nevertheless, the substructure must be implemented such that the Heradesign acoustic panels can be screwed into the CD sections. The spacing of the cross and main sections as well as the hangers must be matched. It is not permissible to fasten Heradesign acoustic panels by gluing or by gluing with screws to gypsum board.

Page 112: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

112

Design that is safe against ball throwing according to DIN 18032/Part 3:

Screw pattern:To fasten Heradesign panels in a way that is safe against ball throwing, at least 3 screws must be used per panel width and support. Max. spacing of the screws 315 mm.

When installing maintenance openings with dimensi-ons of 400 x 400 mm or alternatively 400 x 600 mm in panels with formats of 1200 x 600 or alternatively 1250 x 625, the middle section must be recessed for a length

of 500 mm so that it is possible to access the ceiling cavity. Observe the additionally required hangers on the free ends of the CD sections.

Installation of Maintenance Openings

Please note: Fitting pieces with lengths that are < 500 mm must be supported on all 4 sides.

600

max

625

mm

Product Thickness (mm)

Edge Design

Centre distanceof the cross

sections (mm)

Spacing of the load-bearing

sections (mm)

Spacing of the C vernier

hangers (mm)

Heradesign® superfine 35 AK-01

600; Section type: CD section 60/27/0.7

850; Section type: CD section 60/27/0.7

850

Heradesign® fineHeradesign® micro

3535

AK-01AK-01

600; 625 Section type: CD section 60/27/0.7

850; Section type: CD section 60/27/0.7

850

Sports halls:If Heradesign decorative panels are used as a wall covering behind football or handball goals, basket ball baskets, or alternatively behind the baseline in tennis courts, we recommend using an impact net in the affec-ted areas. Heradesign decorative panels are not suitab-le as an “impact wall”.

Protective function requirements: Walls may only be covered with Heradesign decorative panels as of a height of 2 metres. Heradesign decorative panels are not considered to be an “impact reducing material”, which means they don’t meet the protective function requirements for wall coverings in the contact zone of persons.

Page 113: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

113

Ceiling in a F 30 design with Heradesign® fine or Heradesign® micro panels

Thickness 25 or 35 mm, screwed onto CD sectionsCertificate: ABP 3413/9499-MPA BS Test institute: iBMB Braunschweig

Ceiling in an EI 30 designwith Heradesign® fine A/2 panels

Ceiling in an EI 30 designwith Heradesign® superfine panels

1 Heradesign superfine, 25 mm2 Knauf GKF- A2 panel, 15 mm3 CD section 60/27/064 Heralan DP-5 rock wool,

thickness 30 mm, 2-layer5 Heradesign screws 4.5x50 mm6 Knauf TN 3.5x35 mm screws spacing max 170 mm7 Section connector8 E connection section9 Vernier hanger

= 12 mm

1 15 5 562 3

8 877 9 9

4 43

Edge conn with drywall frieze

1 Heradesign panel, 25 or 35 mm2 Dry-wall screw 5x40 mm,

spacing 290 mm, set skew3 CD section 60/27/0.64 Contact angle 24 x 24 mm,

alt. E-section5 Heralan DP-5 lining, 80 mm,

alternatively 2 x 40 mm6 Quick hangers with tension springs,

alternatively with vernier hangers

Edge connection with E-section

aR

Detail A3

12

45

6

Connection with a simple contact angle

Detail A2

12

6

34

5

Thickness 25 mm, screwed onto CD sectionsCertificate: MA 39 - VFA 2006-0641.01

1 Heradesign® fine/A2, 25 mm2 CD section 60/27/0.63 Heralan DP-5 rock wool,

thickness 40 mm, alt. 2 x 30 mm4 Heradesign screws 4.5 x 50 mm5 Section connector6 E connection section7 Vernier hanger

1 2

6

4

57

32

Detail A4

Thickness 25 mm, screwed onto CD sectionsEdge connection with drywall frieze and shadow gapCertificate: MA 39 - VFA 2006-0699.01

Detail A5, A6

Page 114: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

114

Rust protected, universal dry-wall screw for attaching Heradesign acoustic panels to laths and CD sections. Partial thread, screw head with Torx T20Requirements: depending on the width of the panel and the centre distance, at least 2 screws; version that is safe against ball throwing at least 3 screws.Minimum spacing: 600 or 300 mm

625 or 312 mm

Please note:Not suitable for indoor swimming pools and outdoor applications.

Mounting Information:

For the implementation requirements, also see DIN 18168 T.1 „Lightweight ceiling linings and suspended ceilings”, or alternatively DIN-EN 13964 “Suspended cei-lings - requirements and test methods”.Mount E wall connector sections all around (place dowels staggered ca. every 500 mm)Push the CD load-bearing sections into the wall con-nector sections and fasten them to the pre-assembled hangers.

Distribute cross sections symmetrically (equal border fields)

Start panel installation from the centre of the room.Press the panels in and align them longitudinally in the bracing, transversely to the direction of the section and fasten them with rust-protected dry-wall screws (head diameter 9 mm) to the load-bearing tracks. For each panel width and centre distance, 2 drywall screws (DIN 7997) are required. For 15 mm thick panels, or alterna-tively for the version that is safe against ball throwing, 3 drywall screws are required. - Square panels: Observe the installation direction mar-ked on the back when installing the panels.Cross joints: 4 panel corners meet at one point, which means increased accuracy is required when installing. For F 30 constructions as per DIN: Set the screws skew at an angle of 10 degrees or use washers. Only use approved hanging systems.

Screws:Wood or dry-wall screws with special tips, fine thread, partial thread, and bugle head screws with milled ribs on the underside are suitable. Head diameter 9 mm. The necessary corrosion protection must be matched to the conditions prevailing in the room. The screw heads must be set to be flush with the panel surface and after installation, they must be covered with a paint supplied by the manufacturer or an equivalent.Film or mineral wool is inserted piece by piece with the installation of the acoustic panels. Film joints and con-nections must be masked off. A PE film with a thickness of up to 15 μm doesn’t degrade the sound absorption of the underlying absorber and is recommended as trickle protection for mineral wool lining.Damaged or soiled panels or panels with colour deviati-ons shouldn‘t be installed.

Corrosion protection: To find suitable corrosion pro-tection for screws for applications in swimming pools, underground garages, sheltered outdoor applications or other special applications, please contact your screw supplier or alternatively screw manufacturer.

Heradesign Screws

Dimensions mm For panel thickness mm

Packaging units pieces/boxLength Ø

50 4.5 25 200

60 4.5 35 200

Panel thickness (mm) 15 25 35 100 125

Screw dimensions, Heradesign screws (mm) 4.5/30 4.5/50 4.5/60 – –

Screw dimensions according to DIN 7997, ÖNORM M5027 (mm)

4.5/35 4.5/45 4.5/60 L 140 L 160

Page 115: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

115

Installation Photos

Applying the ceiling grid. Stagger the position of the joints of the CD sections. Additional hanger for each section joint.

Aligning the CD sections with a spirit level or laser level. Finished ceiling grid.

Installing the panels by means of supports. Press the panel onto the section with the ball of the hand while screwing. There mustn’t be a gap between the panel and the section. Only work with the panels with clean hands and a clean tool.

Align the panel rows with an installation lath. Panel joints must be positioned to be centred under the section. No free, suspended panel joints are allowed.

Insertion of Heralan absorber panels one by one along with the installation of the Heradesign panels. Panels that get jammed bet-ween the sections are cut to size.

Alternative: Insertion of PE sheeting as trickle protection or a vapour barrier matching the installation of the Heradesign panels. Stick sheet joints together.

Page 116: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

116

Installation with Heradesign Concrete Decorative Screws

* Covering dimensions of the visual panel: For alternately positioned shiplap, the panel dimensions increase by 15 mm in each case to 1215/615 mm.

100

mm

100 mm

Fastening schema for 2 fastening points*

1/2

1/2

200 mm 200 mm

Recommended fastening schema for 5 fastening points

*Please note:Panel corners can drop by more than 3 mm over time and exceed Class 2 evenness according to DIN EN 13168.

Product Thickness (mm) Edge Design Panel Dimensions (mm) *

Heradesign® micro plus 25 mm/MW 100, 125 AK-01 1200/600

Page 117: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

117

Mounting Information:• Check surface for unevenness

(remove ridges, smooth out unevenness)• Distribute the ceiling symmetrically

(equal border fields).• Press the panels in and align them in the

bracing. Fasten with Heradesign concrete decorative screws. For each panel, place at least 2 screws in the quarter points of the elements or alternatively 5 fastening elements.

Panel thickness: 100 125 mmScrew length: 125 150 mm

Please note:Heradesign concrete decorative screws or DDS concrete screws are not suitable for hollow cor-ners, porous concrete or brick substrate.

Heradesign® Concrete Decorative Screws

Heradesign® DDS Concrete Screws

Fastening to concrete

For underground garages and applications where increased corrosion protection is necessary, we recommend using Heradesign® concrete decorative screws. The corrosion resistance of the DDS con-crete screw is too low for this.

Page 118: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

118

Facing panel

Wall CoveringMounting on laths and vibrating platesSpecial construction to achieve shorter reverberation time with high sound insulation. This can improve the

impact sound insulation of ceilings as well as the sound insulation measurement of walls by up to 10 dB, depen-ding on the existing construction and the assembly that has been selected.

Angularly flexible facing panels for walls and ceilings

Attention: For increased demands on sound insulation, a layer of gypsum fibre board / gypsum board / OSB panels can be placed between the substructure and the Heradesign panel. Nevertheless, the substructure must be implemented such that the Heradesign acoustic panels can be screwed into the wood laths, or alterna-

tively CD sections and the increased load can be borne safely. The spacing of the main and cross sections as well as the resilient brackets or alternatively the han-gers must be matched. It is not permissible to fasten Heradesign decorative panels by gluing or by gluing with screws to gypsum/OSB boards.

Ceiling covering – installation on hanging lath frame / hanging CD sections

3

42

1 5

5

Resilient bracket on elastic baseWood lath 60/40Heradesign decorative panel, screwed Heralan rock wool, RD ca. 50 kg/m3 Elastic base strips

12345

U-hanger with vibration damping

Wood lath 60/40

Heradesign decorative panel

Heralan rock wool, RD ca. 50 kg/m3

Vibration hanger with hanging wire, tension springs with CD hanger

Gypsum fibre board, thickness 12.5 mm

Resilient bracket on elastic base

CD section 60/27/0.7

1

2

3

4

5

6

7

8

1

3

2 4

48

6

5

2

6

4

3

7

Page 119: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

119

Mounting Information:

For the design requirements, see DIN 18168 T.1 „Lightweight ceiling linings and suspended ceilings”.Install wood laths or alternatively CD sections 60/27/07 with the required centre distance on resilient bracket with elastic base or with U-hangers with vibration damping.Distribute the tracks or CD sections symmetrically; make sure the end fields are the same size.Press the panels in and align them longitudinally in the bracing, transversely to the direction of the laths and fasten them with rust-protected screws (head diameter 9 mm) to the supporting structure. Depending on the

width of the panel and the centre distance, at least 2 screws are necessary.- Square panels: Observe the installation direction marked on the back when installing the panels.Cross joints: 4 panel corners meet at one point, which means increased accuracy is required when installing.For F 30 / EI 30 ceilings, don’t use any elastic damping elements – only metal resilient brackets alone.Set the screws skewed by approximately 10º.Screws: Wood or dry-wall screws (with special tips for CD sections) with partial thread, and countersunk heads are suitable. Head diameter:

9 mm. The necessary corrosion protection must be matched to the conditions prevailing in the room.The screw heads must be set to be flush with the panel surface and after installation, they must be covered with a paint supplied by the manufacturer by request or an equivalent.Film or mineral wool is inserted piece by piece along with the installation of the decorative panels. Film joints and connections must be masked off. A PE film with a thickness of up to 15 μm doesn’t degrade the sound absorption of the underlying absorber and is recom-mended for mineral wool lining.Damaged or soiled panels or panels with colour devia-tions shouldn‘t be installed.

Panel thickness (mm) 15 25 35

Screw dimensions Heradesign screws (mm) 4.5/30 4.5/50 4.5/60

Screw dimensions according to DIN 7997, ÖNORM M5027 (mm) 4.5/35 4.5/45 4.5/60

Page 120: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

120

Page 121: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

121

3. Application and Handling

Page 122: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

122

Application and Handling

Durability of Heradesign Decorative Panels

Medium, attack Comments

1) Water and water vapour Not resistant to direct, long-term effects of water (rain, condensation, moisture from soil, capillary action). This results in the panels swelling as well as reduced mechanical stability and efflorescence of magnesium sulphate. Likewise, per-manent exposure to water vapour (rel. humidity > 90 %) leads to swelling and a reduction of mechanical stability.

2) Organic solvents* (e.g. acetone, alcohol, ether, petrol, benzene, halogenated hydrocarbons, oils etc.)

Contact with organic solvents in a liquid form (local exposures or spots) causes them to be partly absorbed by the panel and released as vapour. No adverse effects to the mechanical stability of the panels has been observed (except for flammability after exposure to flammable solvents, as well as dirtying the visible surface) Solvent vapours in concentrations that are allowed by hygienic regulati-ons for the workplace, have no effect on the building biological properties of the magnesite bonded Heradesign decorative panels according to findings so far.

3) Acids and alkalis a) Acids: Magnesite bonded Heradesign decorative panels are not resistant to the direct effects of acids. Depending on the concentration and strength of the acid, direct contact to an acid will cause localised dissolving of the bonding agent in the panel. Generally, harmless salts are formed (party with a violent reaction). In some cases acid vapours occur, which are within the workplace hygienic regulations (e.g. common in chemical laboratories or similar facilities), and which do not damage the products.

b) Alkalis: The effect of alkalis on the panels causes the bonding agent to soften and is comparable to the effects of water.

*) Questions about applications regarding contact to specific solvents/solvent mixtures/ or exposure to high concentrations of solvents must be discussed individually with Heradesign’s technical customer service.

Page 123: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

123

Transport and Storage

TransportHeradesign decorative panels are delivered on pallets with a protective cardboard cover. They may only be transported in closed trucks or cars and must be protec-ted against moisture during the entire trip.Only stack a maximum of 2 pallets. Pallets and boxes must be secured against tipping, slipping, and physical damage.

Material AcceptanceHeradesign decorative panels are produced and chek-ked and transported to the construction site with great care.

Nevertheless, during material acceptance, you should always verify the delivery slip:• Number of package units (pallets, boxes, m2)• Compare the contents of the package units accor-

ding to the delivery slip to the labels on the pack-aging.

• Accessories:dowels, screws, spare paint, profiled sections or other additional items

• Are the goods or parts thereof damaged?

If there is any transport damage, insufficient quantities, or other discrepancies to the delivery slip and waybill, have this certified by the driver. Also, immediately inform the dealer that shipped the goods. Flawed panels must not be used.

Panel storageAs the processor, you are responsible for proper storage of the goods at the construction site and for their trans-port to the place of installation.

And, this is how to do it correctly:• Panels must be stored flat and stably in a dry, clean,

swept-out room to protect them against moisture, soi-ling, and dust.

• The existing packaging is not protection against the rain.

• Only stack a maximum of 2 pallets of magnesite bon-ded Heradesign decorative panels (max. height 250 cm) on top of each other.

• Only store 1 or 2-layer Heradesign decorative panels in rooms where the following storage conditions are ensured, depending on the climate conditions of the designated installation site. For subsequent installati-on in heated or air-conditioned rooms: max. relative air humidity of 75 % and the temperature must not drop below +7 ºC or rise above 30 ºC. For unheated rooms such as underground garages etc. the following applies: max. relative air humidity of 85 % and minimum temperature of +5 ºC.

• Therefore, Heradesign decorative panels must be very specifically protected against moisture at the construction site. Absolute dry storage is mandatory. The relative humidity must not exceed a range of 35 to 65 % at 10 to 30 ºC. Do not store in an underground garage or basement.

Page 124: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

124

Areas of Application and Handling of 3-layer Heradesign® Decorative Panels

Area of ApplicationFor 3-layer Heradesign decorative panels, it is necessary to not

exceed relative air humidity of 35 – 65 % at 10 – 30 ºC when working with the panels (processing conditions). High construction humidity can have negative consequences.The guideline for the shrinkage and swelling is 0.5 mm over 1000 mm, and 1.0 mm over 1000 mm for very high air humidity. These products must be very specifically protected against moisture at the construction site. Absolute dry storage is mandatory.When sorting or laying out the panels, the supplied protective film must always be used between the panels. In this connection, please also observe the possibility of rising damp in new buildings.

Colour and Surface

Heradesign® styleThe HPL decorations from the Argolite collection are colour consis-tent. If custom colours from RAL or NCS are selected where a paint coating is needed, then minor colour deviations can‘t be excluded in spite of close monitoring of the colour mixing.

Heradesign® deluxeThe HPL bases with real wood veneer are wire/half wire shifted as a standard. Irregularities in the growth, swirls, deviations in the grain and colour are natural.For large quantities, you must specify which panels will be installed in the same room or on the same wall because of the veneer colour. One must proceed on the assumption that different veneer sources may be used. The characteristics of natural wood surfaces given here are permissible according to a defined tolerance framework and are not subject to complaints. We recommend sorting the elements before installation. The colour of stained or painted surfaces may deviate from samples prepared in advance. The same also applies to the lustre of the coating.

Installation and System Conditions

The installation of Heradesign acoustic ceilings is part of interior decorating and must only be carried out under controlled humidity and temperature conditions. All dust-causing construction measures must be completed before starting the installation.

It must no longer be possible for moisture or rain water to penetrate through walls, ceilings, and openings.

Suitable working conditions are:- dry and clean rooms- plastering and screed work have been completed for at least 3

weeks- installed and glazed windows and doors for controlled tempera-

tures and ventilation

Hanging systems must be installed in accordance with the manufacturer‘s guidelines, according to DIN 19168 „Lightweight cei-ling linings and counter ceilings“, as well as according to EN 13964 „Suspended ceilings - requirements and test methods“.

Evenness: The greatest deviation from the evenness of the subs-tructure may only be a maximum of 2 mm per meter of length; howe-ver, it must not exceed 5 mm over a length of 5.0 m.

After installing the Heradesign panels, other tradesmen may only perform finishing work on the ceiling.

Expansion joint: For large ceiling areas that are installed with screw in rooms with strongly changing high air humidity, we recommend placing an expansion joint at least every 10 m. When connecting these ceilings to fixed limiting structural elements, care must also be given to sufficient expansion possibilities. Here, the free edge distance should be at least 8 mm.

Vibrating structural elements: Suspended ceilings with insertion or screw mounting in which angularly flexible hangers are fastened to structures that tend to have vibrations such as trapezoidal sheet metal roofs, steel or wood binders / trusses, must be secured by hangers placed on an angle (at least 10 % of them) to counter hori-zontal displacement. For screw installation, at least 3 screws must be used per panel width and support.

Resistance to wind loading: If it is to be expected that suspended ceilings in a covered outdoor area or in the inside of a building will be subject to wind loads (e.g. by open windows, doors, etc.), then the appropriate measures must be taken to ensure that the top layer and the substructure can withstand suction and or pressure wind loading.

Maximum span of the panel: 600 mm.

Film (thickness < 15 μm) is recommended as trickle protection for mineral wool lining.

Processing

For cutting Heradesign decorative panels at the construction site, we recommend using a fast running circular saw with a carbide-tipped saw blade (diameter approx. 400 mm) and dust extraction. Subsequent bevelling can be carried out with a diagonally set saw blade, by san-ding with coarse sand paper, or a plane. Cut the panels such that the visual surfaces are not dirtied by saw dust. See Page 54.

If possible, the finishing work should be done outdoors. Always work with clean hands and clean tools.

The cutting must not be done using the stack of panels as a base.

Please observe the employee protection provisions and safety regulations.

Page 125: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

125

Ideal, all constructions and products

Dry range, all products, only specific construction

Humid range, only specific constructions and pro-ducts with additional equipment – constructional con-sultation required

Condensation range, only specific constructions, all products with additional equipment – constructional consultation required

Areas of Application for 1 or 2-Layer Heradesign Decorative Panels

in indoor areasHeradesign® superfine, Heradesign® fine, Heradesign® fine/A2,Heradesign® industry, Heradesign® micro, Heradesign® plano

3

2

4

1

[%] R

elat

ive

air

hum

idity

(m

ax 1

2 h

dai

ly a

vera

ge)

Too humid

Humidity range

Ideal

Dry range

Too dry

Application limit

Range limit

[ºC] Temperature(max. 12 h daily average)

Page 126: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

126

Processing of 1 or 2-Layer Heradesign Decorative Panels

The work should be a compliment to the master.Heradesign decorative panels are high-quality visual panels that are carefully packed and checked and delivered to the construction site. The second important factor for a beautiful ceiling, however, is exact processing and suitable work conditions. This is because only careful work and high product quality ensure a satisfactory result.

Material and Air HumidityDue to the organic component, wood, in the Heradesign panels, slight deviations in the format can‘t be excluded. Likewise, the panels also contract and expand if there is strongly fluctuating air humidity.

• Final shrinkage in a standard climate of 23 ºC / 50 % r.h. is max. ± 1 % for length changes and max 3 % for width changes. Therefore, special attention must be given to the temperature and air humidity during installation (if necessary heat, ventilate, back-ventilate the ceiling or dehumidify the air under constant monitoring), in order to ensure constant installation conditions.

• Production tolerance for the nominal dimensions is ± 1 mm; for lengths over 1250 mm ± 2 mm.

Colour and StructureAs a consequence of the natural raw materials magnesite and wood, differences to the colour and structure may occur. Especially for white coloured decorative panels, there may be changes to the degree of brightness due to the wood wool structure as well as due to the influence of light sources and the viewpoint of the observer. Only the same type of panels may be installed in a ceiling. Therefore, constant-ly check the panels before installation as well as the overall impression of the ceiling, right from the beginning. The installation direction must be observed for square panels. This is identified by a rectangular recess on the back, upper panel edge. Always install with the recess in the same direction. Coloured panels (except RAL 9010) are only ordered externally. No liability can be assumed for colour deviations in the event of partial deliveries or deviations from the colour chart.

Colour QualitySilicate paint based on potassium silicate and organic bonding agents is used for colouring Heradesign panels in white, pastel and solid colours. The building biology properties of the panels are retained as a result. Heradesign® superfine, Heradesign® fine, Heradesign®

fine/A2, Heradesign® industry and Heradesign® micro can also be coloured multiple times without losing the outstanding sound absorp-tion properties. The coat of paint must always be applied to the panel with a spray gun in a longitudinal and transverse direction.Installation and System Conditions

• The installation of Heradesign acoustic ceilings is part of interior decorating and must only be carried out under controlled humidity and temperature conditions. All dust-causing construction measures must be completed before starting the installation.

• It must no longer be possible for moisture or rain water to penetrate through walls, ceilings, and openings.

• Only install panels in rooms where the following conditions are ensured: For heated or air-conditioned rooms, the maximum relative air humidity must not exceed 75 % and the temperatures must not be below +7 ºC or above +30 ºC. For unheated rooms such as under-ground garages etc. the following applies: max. relative air humidity of 85% and minimum temperature of +5 ºC. If Heradesign decorative panels are to be installed subsequently in rooms with central heating, we recommend acclimatising the panels for at least 7 days in a room with the same conditions.

• Suitable working conditions are:- dry and clean rooms- plastering and screed work have been completed for at least 2 weeks- installed and glazed windows and doors for controlled temperatures

and ventilation

• Hanging systems must be installed in accordance with the manufacturer‘s guidelines, according to DIN 19168 „Lightweight cei-ling linings and counter ceilings“, as well as according to EN 13964 „Suspended ceilings - requirements and test methods“.

• Evenness: The greatest deviation from the evenness of the sub-structure may only be a maximum of 2 mm per meter of length; however, it must not exceed 5 mm over a length of 5.0 m.

• Observe installation direction for square panels. The installation direction is marked on the back by a recessed groove.

• After installing the Heradesign panels, other tradesmen may only perform finishing work on the ceiling.

• Expansion joint: For large ceiling areas that are installed with screw mounting in a covered outside area or in rooms with strongly changing high air humidity (rel. hum. > 80 %), we recommend placing an expansion joint at least every 10 m. When connecting these cei-lings to fixed limiting structural elements, care must also be given to sufficient expansion possibilities. Here, the free edge distance should be at least 8 mm.

• Vibrating structural elements: Suspended ceilings with insertion or screw mounting in which angularly flexible hangers are fastened to structures that tend to have vibrations such as trapezoidal sheet metal roofs, steel or wood binders / trusses, must be secured by hangers placed on an angle (at least 10 % of them) to counter horizontal dis-placement. For screw installation, at least 3 screws must be used per panel width and support.

• Resistance to wind loading: If it is to be expected that suspended ceilings in a covered outdoor area or in the inside of a building will be subject to wind loads (e.g. by open windows, doors, etc.), then the appropriate measures must be taken to ensure that the top layer and the substructure can withstand suction and or pressure wind loading.

• Maximum span of the panel: 625 mm.

• Film (thickness < 15 μm) is recommended as trickle protection for mineral wool lining.

• Please note: Heradesign decorative panels are generally not sui-table for glue mounting. A combination of gluing and screwing must also not be used.

Processing

• For cutting Heradesign decorative panels at the construction site, we recommend using a fast running circular saw with a carbide-tipped saw blade (diameter approx. 400 mm) and dust extraction. Subsequent bevelling can be carried out with a diagonally set saw blade, by sanding with coarse sand paper, or a plane.Cut the panels such that the visual surfaces are not dirtied by saw dust. See Page 54.

• If possible, the finishing work should be done outdoors. Always work with clean hands and clean tools.

• The cutting must not be done using the stack of panels as a base.

• Slight damages and screw heads, edges, and panel surfaces will be carefully covered with paint after installation. Only apply a small amount of paint to avoid colour differences.

• Installation methods with cross joints are difficult to use (4 panel corners at one point is laborious).

• Please observe the employee protection provisions and safety regulations.

Page 127: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

127

For subsequent painting of Heradesign wood wool visible panels, it is decisive whether you are dealing with unpainted surfaces or standard surfaces that Heradesign has painted. But even more important is the choice of paint and colour that you want to apply. For panels that were painted at the factory, a water-soluble silicate paint with potassium silicate and copolymerisates as bonding agents is used. Therefore, the composition of the new paint must be compatible with the existing paint and be of the same quality as the specified and tested, reference paints. Only use “Harmful substance tested” paints.

The following cases must be differentiated:

• White paint on a white surface (restoration)Recommended paint: StoColor Rapid, application quan-tity approx 0.20 litres/m2, one coat

• Other paint colours on surfaces painted in the factory or surfaces in natural tone 13 when restoring with the same colour. Recommended paint: StoColor In, application quantity approx 0.20 to 0.25 litres/m2,one coat. In case of a new colour, a greater application quantity may be necessary.

• White paint on surfaces that were not painted in the factory (raw goods)Recommended paint: StoColor Rapid, application quan-tity approx. 0.25 to 0.3 litres/m2 per coat, apply two coats.

• Other colours on surfaces that were not painted in the factory (raw goods): Recommended paint: StoColor In, application quanti-ty approx. 0.25 to 0.3 litres/m2 per coat, at least two coats.

• Heradesign® fine A/2 panels are always coloured with StoColor. Application quantity approx. 0.25 to 0.3 litres/m2 per coat

General Information

Equipment for applying paintThe paint is basically applied with an airless paint spray-er, whereby each coat of paint must be applied in two different directions at different angles to the surface of the panel so that the paint can penetrate into all pores and openings in the surface. If you apply two coats, the first coat must be dry before applying the second coat.

Basically, only enough paint should be applied so that the panel is perfectly covered. Too much paint causes excessive moisture to be added and can cause the panels to warp and swell. The application of the paint and the coverage must be checked constantly from the floor. The manufacturer’s regulations and instruction manuals must be observed when working with the paint and operating the equipment.

Protective Measures for Bordering Surfaces, Floors, etc. Bordering surfaces, windows, and floors etc. must be covered. Water can be used to clean surfaces that have been dirtied with paint, while they are still wet. Dried paint can only be removed with a paint stripper and that may cause damage to the subsurface.

Safety InformationPay attention to the information regarding protective measures in the safety data sheets from the paint manufacturer. If necessary, protect your head, eyes, respiratory system, and skin by wearing protective masks, goggles, gloves, and work clothing.

Miscellaneous InformationFor underground garages or rooms where the humidity is above 80%, a film preservative must be added to the paint. Observe the protective measures when handling.

Subsequent Colouring of 1 or 2-Layer Heradesign Panels

Page 128: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

128

Handling the panels at the construction site: Always lift the panels vertically from the stack.

When lifting the panels from the stack, never drag them over the edge of the stack to prevent damage to the visual side.

Only carry panels on the edge. Never lean the panels on an angle against the wall during installation and subsequent painting. This causes the panels to warp – warped panels can no longer be installed.

Installing the first row of panels:Always start installing from the centre of the room, which has been pre-marked.

Arranging the screws or alternatively the panels with auxiliary tracks. Make sure that there is enough space at the end of the panel to prevent the edge from dropping out. Make sure the screw head is flush to the surface of the panel. The auxiliary lath is removed after installing the first row of panels.

Falsch!

Instructions for Processing 1 or 2-Layer Heradesign Decorative Panels

Page 129: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

129

Paint over the screw heads: Use a fine brush to cover the screw heads with the colour of the panels after installation.

Creating the edge bevel: The bevel is made with coarse sand paper or a saw blade set on an angle.

Painting the bevel: Use a brush or a thin paint roller to apply the paint.

Touching-up small flaws in Heradesign® micro or Heradesign® planopanels: The flaws / chipped edges are filled with acrylate or plastic wood, smoothed with a putty knife, and covered with the panel colour after drying.

Joints with Heradesign® micro panels can be filled in with Knauf arcylate sealing compound. Can be painted over with silicate paint.

Not this way! The screw heads must be flush with the surface of the panel.

Falsch!

Edges and Screws

Page 130: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

130

Cutting and Drilling

Falsch!

Table sawLay the panel down with the exposed side up. Always work with a safety guard, guide and an extraction system.

Circular sawLay the panel down with the exposed side up. Always work with a guide and an extraction system. Support the free end of the panel.

JigsawLay the panel down with the exposed side down. Always cut with a guide.

Not this way!Never cut panels in a stack.

Jack sawLay the panel down with the exposed side up. Always work with a guide. Support the free end of the panel.

DrillingLay the panel down with the exposed side up.

Page 131: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

131

Dangling Fibres Carefully remove individual loose fibres with a knife.

Chipped FibreCover chipped fibre with a fine brush or a spray gun using the supplied paint or an equivalent.

BrushingEfflorescence, dust, etc. can be removed with a soft brush. Set loose fibres with StoPrim Plex primer.

Touching-up chipped fibre or small, unclean areas of the panels: The paint is sprayed on carefully with a spray gun using various spraying angles.

Touching-up

Page 132: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

132

Page 133: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

133

4. Certificates

Page 134: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

134

Page 135: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

135

Page 136: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

136

Page 137: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

137

Page 138: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

138

Page 139: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

139

Page 140: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

140

Heradesign® superfine

Heradesign® fine

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient according to ASTM – C423

Panel type

Without backfillingHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineWith mineral woolHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineWith flax woolHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fineHeradesign® fine

Panelthickness(mm)

1515252525252535353535

151525252525252525253535353535

0.120.180.250.750.360.210.350.750.440.75

0.390.430.750.850.840.490.850.850.840.80

0.780.970.950.650.690.980.950.600.680.65

1.040.890.700.700.700.870.650.800.770.70

0.650.630.650.700.730.670.800.700.790.85

0.530.790.850.850.770.730.850.800.720.85

0.700.750.750.750.750.750.800.750.750.75

CC

CC

C

0.70 (LMH)0.70 (LH)

0.75 (L)0.70 (L)

0.70 (LH)

0.100.40

0.100.30

0.35

15252525253535353535

3030402752303040130230275

303040403030401003040

2660126601

9666/WS9666/WS

2660126601

9666/WS9666/WS

266019666/WS

28.04.9428.04.9419.01.9819.01.9828.04.9428.04.9419.01.9819.01.9828.04.9419.01.98

s

s

p

p

s

s

p

p

s

p

302753080801001101102002753029060110210

30403080

80 PE50

80 PE110 PE

50403040606060

CH/EMPA DübendorfCH/EMPA DübendorfA/TGM WienD/Müller-BBMD/Müller-BBMTong Ji Uni ShanghaiD/Müller-BBMD/Müller-BBMTong Ji Uni ShanghaiA/TGM WienA/TGM WienCH/EMPA DübendorfCH/EMPA DübendorfCH/EMPA DübendorfCH/EMPA Dübendorf

D/Müller-BBMD/Müller-BBMA/TGM WienA/TGM WienD/Müller-BBMD/Müller-BBMA/TGM WienA/TGM WienD/Müller-BBMA/TGM Wien

186.074186.074

10225/WS1880818808

1880818808

10225/WS10656/AB119.203176.884176.884176.884

11.12.8511.12.8526.02.0112.11.9012.11.9004.03.0312.11.9012.11.9004.03.0326.02.0118.06.0309.04.7605.06.8405.06.8405.06.84

0.160.450.200.740.650.450.790.900.750.850.200.400.310.470.50

0.510.960.600.940.821.000.810.880.950.800.700.790.981.120.96

1.000.781.000.740.720.900.740.960.800.801.000.981.030.960.96

0.920.840.750.580.710.650.770.850.700.750.750.940.840.860.89

0.570.660.700.680.990.800.740.920.800.800.800.830.840.850.88

0.690.710.850.800.690.900.740.920.950.900.901.031.020.980.98

0.750.800.750.750.800.850.800.900.800.800.800.900.900.900.90

C

BB

03003080200300040100200

00000000000

CH/EMPA DübendorfCH/EMPA DübendorfA/TGM WienA/TGM WienA/TGM WienD/Müller-BBMA/TGM WienA/TGM WienD/Müller-BBMD/Müller-BBMD/Müller-BBM

186.074186.074

10225/WS10225/WS9821/WS

252999454/WS10225/WS

213072130721307

11.12.8511.12.8526.02.0126.02.0104.09.9818.10.9320.05.9726.02.0120.03.9220.03.9220.03.92

0.05

0.20

0.300.35

0.270.48

0.00

0.040.050.100.100.250.150.550.100.090.190.36

0.080.100.150.200.500.460.550.200.230.400.59

0.140.280.250.600.700.500.350.450.740.740.57

0.280.660.650.750.500.410.450.850.740.550.52

0.730.470.750.600.550.600.600.700.620.740.71

0.600.490.700.800.700.780.800.850.850.860.83

0.300.400.450.550.550.500.500.550.600.600.60

DDD

DD

0.35 (MH)0.50 (MH)0.55 (H)

0.45 (LH)0.45 (MH)

s

s

p

p

p

s

p

p

s

s

s

s

s

p

s

s

p

s

s

p

p

p

s

s

s

s

Spacingto ceiling (mm) 1)

Backfilling(mm)

Country/Test Institute No. Date s

p 63 125 250 500 1000 2000 4000 Absorber-class

wNRC2)entire range

Test item Certificates Degree of sound absorption s , pFrequencies (HZ)

0.75 (M)

0.800.80

Panel type Panel

thickness

(mm)

Spacingto ceiling(mm) 1)

Backfilling(mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2)entire range

Test item Certificates Degree of sound absorption pFrequencies (HZ)

Without backfilling15 30 0 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.05 0.15 0.35 0.70 0.65 0.70 0.45 0.40 (MH) D15 283 0 A/TGM Wien 10656/AB 18.06.03 p 0.10 0.35 0.55 0.45 0.50 0.60 0.75 0.55 0.50 (LH) D25 0 0 A/TGM Wien 10575/WS 23.09.02 p 0.05 0.05 0.15 0.25 0.50 0.80 0.70 0.45 0.35 (H) D

Heradesign® 25 30 0 A/TGM Wien 10575/WS 23.09.02 p 0.05 0.10 0.20 0.45 0.70 0.55 0.75 0.50 0.45 (MH) D superfine 25 275 0 A/TGM Wien 10575/WS 23.09.02 p 0.30 0.50 0.40 0.50 0.65 0.75 0.55 0.50 (H) D

35 30 0 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.10 0.25 0.55 0.80 0.65 0.85 0.55 0.55 (MH) D35 265 0 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.40 0.55 0.45 0.60 0.75 0.90 0.60 0.55 (H) D

With mineral wool15 30 30 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.10 0.45 0.90 0.95 0.80 0.85 0.75 0.75 C15 283 40 A/TGM Wien 10656/AB 18.06.03 p 0.25 0.65 0.85 0.90 0.90 0.85 0.85 0.85 0.90 A

Heradesign® 25 30 30 A/TGM Wien 10575/WS 23.09.02 p 0.05 0.15 0.50 0.95 0.90 0.80 0.90 0.80 0.80 B superfine 25 275 40 A/TGM Wien 10575/WS 23.09.02 p 0.70 0.90 0.90 0.90 0.80 0.95 0.90 0.90 A

35 30 30 A/TGM Wien 10656/AB 18.06.03 p 0.00 0.15 0.60 0.95 0.90 0.85 0.95 0.85 0.85 B35 265 40 A/TGM Wien 10656/AB 18.06.03 p 0.20 0.70 0.90 0.90 0.90 0.90 1.00 0.90 0.90 A

With flax wool Heradesign® 25 30 30 A/TGM Wien 10575/WS 23.09.02 p 0.20 0.50 0.90 0.90 0.70 0.90 0.75 0.75 (H) C superfine 25 275 40 A/TGM Wien 10575/WS 23.09.02 p 0.65 0.80 0.75 0.75 0.80 0.90 0.80 0.80 B

Absorber-class

Sound Absorption Values

Page 141: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

141

Heradesign® micro

Acoustic Elements

Heradesign® plano

Heradesign® fine/A2

1) Distance to the ceiling: distance from lower ceiling edge to upper edge of the decorative panel (without backfilling) PE: with PE film 0.2 mm thick, between panel and backfilling2) NRC noise reduction coefficient as per ASTM - C423*) Ceiling layer coloured

pacingto ceiling (mm) 1)

Panel type Thick-totalness(mm)

Element construction

Ceiling Corelayer(mm) (mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000

Test item Certificates Degree of sound absorption pentire range

wNRC2) Absorber-class

Frequencies (HZ)

Without backfilling130 25 *) 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.69 0.86 0.96 0.95 0.93 1.00 0.95 0.95 A125 15 110 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.10 0.33 0.41 0.42 0.71 0.84 0.45 0.45 (H) D80 15 65 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.05 0.12 0.37 0.42 0.68 0.82 0.40 0.35 (H) D130 25 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.79 0.91 0.91 0.81 0.81 0.84 0.90 0.85 (L) B125 15 110 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.11 0.31 0.43 0.42 0.79 0.86 0.45 0.45 (H) D90 25 65 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.07 0.19 0.50 0.80 0.78 0.77 0.55 0.50 (MH) D130 25 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.47 0.40 0.35 0.29 0.29 0.33 0.35 0.35 (L) D130 25 105 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.15 0.44 0.48 0.42 0.32 0.32 0.45 0.40 (L) D90 25 65 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 p 0.13 0.36 0.43 0.30 0.25 0.26 0.35 0.30 (L) D

Heradesign® superfine 25 mm/MWHeradesign® superfine 15 mm/EPSHeradesign® superfine 15 mm/PFHeradesign® fine 25 mm/MWHeradesign® fine 15 mm/EPSHeradesign® fine 25 mm/PFHeradesign® micro plusHeradesign® micro 25 mm/EPSHeradesign® micro 25 mm/PF

Without backfillingHeradesign® fine/A2 25 40 0 A/TGM Wien AB 11068 18.04.05 p 0.05 0.25 0.65 0.60 0.50 0.70 0.50 0.50 (H) DHeradesign® fine/A2 25 280 0 A/TGM Wien 18.04.05 p 0.50 0.65 0.40 0.40 0.60 0.75 0.50 0.45 (LH) DWith mineral woolHeradesign® fine/A2 25 40 40 A/TGM Wien AB 11068 18.04.05 p 0.20 0.80 0.90 0.60 0.65 0.80 0.70 0.65 (LMH) CHeradesign® fine/A2 25 80 80 A/TGM Wien AB 11068 18.04.05 p 0.55 1.10 0.80 0.65 0.65 0.80 0.80 0.70 (L) CHeradesign® fine/A2 25 280 40 A/TGM Wien AB 11068 18.04.05 p 0.75 0.80 0.75 0.65 0.65 0.85 0.70 0.70 (LH) C

Panel type Panelthickness

(mm)

Spacingto ceiling (mm) 1)

Backfilling (mm)

Country/TestInstitute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2) Absorber-class

entire range

Test item Certificates Degree of Sound Absorption s , pFrequencies (HZ)

Without backfillingHeradesign® micro 25 0 0 NL/PEUTZ Mook 1244-1-RA 23.01.03 s 0.16 0.41 0.47 0.32 0.28 0.33 0.35 0.35 (L) DHeradesign® micro 25 30 0 A/TGM Wien 10656/AB 18.06.03 p 0.25 0.45 0.55 0.45 0.40 0.45 0.50 0.45 DHeradesign® micro 25 50 0 CH/EMPA Dübendorf 119.203 09.04.76 s 0.18 0.70 0.52 0.34 0.47 0.46 0.50 Heradesign® micro 25 300 0 A/TGM Wien 9454/WS 20.05.97 p 0.45 0.70 0.60 0.45 0.45 0.50 0.50 0.50 0.50 (L) DHeradesign® micro 35 0 0 A/TGM Wien 9454/WS 20.05.97 p 0.05 0.20 0.40 0.55 0.40 0.30 0.40 0.40 0.40 DWith mineral woolHeradesign® micro 25 30 30 A/TGM Wien 10225/WS 26.02.01 p 0.35 0.75 0.65 0.45 0.40 0.35 0.55 0.45 (L) DHeradesign® micro 25 275 40 A/TGM Wien 10656/AB 18.06.03 p 0.25 0.45 0.45 0.45 0.45 0.45 0.50 0.45 0.45Heradesign® micro 35 30 30 A/TGM Wien 10225/WS 26.02.01 p 0.50 0.55 0.45 0.35 0.35 0.35 0.45 0.40 (L) DWith flax woolHeradesign® micro 25 275 40 A/TGM Wien 9666/WS 19.01.98 p 0.45 0.65 0.60 0.45 0.40 0.40 0.40 0.45 0.45 (L) D

Panel type Panel

Thickness

(mm)

Spacingto ceiling (mm) 1)

Backfilling (mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2) Absorber-class

entire range

Test item Certificates Degree of Sound Absorption s , pFrequencies (HZ)

Without backfillingHeradesign® plano 25 0 0 A/TGM Wien 10548/WS 04.07.02 p 0.15 0.30 0.40 0.30 0.25 0.25 0.30 0.30 DHeradesign® plano 25 30 0 A/TGM Wien 10548/WS 04.07.02 p 0.30 0.40 0.35 0.30 0.25 0.30 0.30 0.30 (L) DHeradesign® plano 25 275 0 A/TGM Wien 10548/WS 04.07.02 p 0.35 0.35 0.30 0.30 0.25 0.25 0.30 0.30 (L) DWith mineral woolHeradesign® plano 25 30 30 A/TGM Wien 10548/WS 04.07.02 p 0.40 0.40 0.35 0.25 0.25 0.25 0.30 0.30 (L) DHeradesign® plano 25 305 40 A/TGM Wien 10548/WS 04.07.02 p 0.40 0.35 0.30 0.30 0.25 0.25 0.30 0.30 (L) D

Panel type Panel

Thickness

(mm)

Spacingto ceiling (mm) 1)

Backfilling (mm)

Country/Test Institute

No. Date s

p 63 125 250 500 1000 2000 4000 wNRC2) Absorber-class

entire range

Test item Certificates Degree of Sound Absorption s , pFrequencies (HZ)

Page 142: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

142

Fire Protection – Building Component Classification for 1-layer Decorative Panels

Construction Description * Classification Certificate

Heradesign® fine / Heradesign® micro, d 25 mmin T-track system suspended as insertion installation, with Heralan DP-5 lining d 2 x 50 mm or with Heralan DP-4 lining d 2 x 60 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® fine / Heradesign® micro, d 35 mmin T-track system suspended as insertion installation (VK-09), with Heralan DP-5 lining d 2 x 50 mm or with Heralan DP-4 lining d 2 x 60 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® fine / Heradesign® micro, d 25 mmscrewed to wood laths 40/60 and suspended, with Heralan DP-5 lining d 80 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® fine / Heradesign® micro, d 25 mmscrewed to CD sections and suspended, with Heralan DP-5 lining d 80 mm

F 30as an independent

ceiling element

Test certificateNo. 3327/3079ABP 3413/9499

BMB BraunschweigD

Heradesign® superfine, d = 25 mmin T-track system suspended as insertion installation, with Heralan DP-5 lining d 2 x 50 mm

EI 30(a<—b)

Classification report No. MA39-VFA 2004 -1945.02

(A)

Heradesign® superfine, d = 25 mm screwed to CD sections 2 x 60/27, with Heralan DP-5 lining d 2 x 30 mm

EI 30(a<—b)

Classification report No. MA39-VFA

2006- 0699.01 (A)

Heradesign® fine/A2, d = 25 mmscrewed to wood laths 80/40, with Heralan DP-5 lining d = 40 m

EI 30(a<—b)

Classification report No. MA39-VFA

2005- 0567.01 (A)

Heradesign® fine/A2, d = 25 mm screwed to CD sections 2 x 60/27, with Heralan DP-5 lining d 40 mm

EI 30(a<—b)

Classification report No.MA39-VFA

2006 0641.01 (A)

Heradesign® fine, d = 25 mmscrewed to wood laths 80/50, with Heralan DP-5 lining d = 50 mm

EI 30(a<—b)

Classification report No. MA39-VFA 2005-

05401.01 (A)

Reinforced concrete slab on IPE 140 supports with suspended counter ceiling made of Heradesign® micro panels, d = 25 mm, edge VK-12, screwed to wood laths.

F 30Counter ceiling alone,in combination withreinforced concrete

ceiling or wooden beam ceiling

Fire Protectionapproval

No Z 3251 of theVKF-AEAI Berne/CH,

19.11.2003

Reinforced concrete slab on IPE 140 supports with suspended counter ceiling made of Heradesign® fine panels, d = 35 mm, edge AK-01, screwed to sheet steel sections. Lining of 40 mm rock wool panel, RD = 100 kg/m2 on Heradesign panels and profiled sections.

F 30Counter ceiling alone,in combination withreinforced concrete

ceiling or wooden beam ceiling

Fire Protectionapproval

No Z 5818 ofVKF-AEAI from

Bern/CH,19.11.2003

* Attention: The classification only applies to the certified design. A reduction of the gross density of the mineral wool or the thickness of the lining or alternatively the panel thickness is not permitted. Only F 30 or F 60 certified hanging systems may be used as a substructure.

Page 143: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

143

Test item Construction Test Institute CertificatesNo. / Date

Results

Ceiling

Heradesign® micro,35 mm

Screw mounted under metal profiled sectionsCD sections 27 x 60 x 0.7 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3 x dry-wall screws/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-204.10.2005

“Safe against ball throwing“ as perDIN 18 032/ Part 3or Class 1A as per EN13964 Appendix D

Heradesign® micro,35 mm

Slide-in installation, hung by means of rigid hangers,in T-sections 24 x 38 mmCentre distance 600 mmEdge Design: VK-09

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

46/903 356-6/Sm/C10.06.2003

“Safe against ball throwing”as per DIN 18 032/ Part 3

Heradesign® fine,35 mm

Screw mounted under metal pro-filed sectionsCD sections 27 x 60 x 0.7 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3 x dry-wall screws/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-304.10.2005

“Safe against ball throwing“ as perDIN 18 032/ Part 3 orClass 1A as per EN13964 Appendix D

Heradesign® fine,35 mm

Screw mounting underwood laths 28/48 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3x Heradesignscrews/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-604.10.2005

“Safe against ball throwing“ as perDIN 18032/ Part 3 orClass 1A as perEN 13964 Appendix D

Heradesign® fine,35 mm

Push-in mounting,hung by means ofrigid hangers,in T-sections 24 x 38 mmEdge Design: VK-09

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

9013895-1/Sc/Kf

20.08.2007

“Safe against ball throwing“ as perDIN 18032/ Part 3 orClass 1A as perEN 13964 Appendix D

Heradesign® fine/A2,25 mm

Screw mounting under wood lath 28/48 mm, Centre distance 600 mm

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

55150/901 0354-704.10.2005

“ball throwing safe” according to DIN 18032/ Part 3 or class 1A according to EN 13,964 Appendix D

Heradesign® superfine,35 mm

Screw mounted under metal profiled sectionsCD sections 27 x 60 x 0.7 mmCentre distance 625 mmEdge Design: AK-01Fastening: 3 x dry-wall screws/support

D Research andmaterials testing institute of Baden-Württemberg,FMPA Stuttgart

901 3895-3/Sc/Kf

20.08.2007

“Safe against ball throwing” as per DIN 18032/ Part 3or Class 1A as perEN 13,964 Appendix D

Heradesign® superfine,35mm

Screw mounting underwood lath 30 x 50 mmCentre distance 625mmFastening:3 x dry-wall screws/support

D Research and materials testing institute, Baden-Württemberg, FMPA Stuttgart

901 3895-2/Sc/Kf

20.08.2007

“Safe against ball throwing” as per DIN 18032/ Part 3or Class 1A as perEN 13,964 Appendix D

Design that is safe against ball throwing

according to DIN 18 032/Part 3

Page 144: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

144

Building Material Classification

Heradesign® superfineHeradesign® fineHeradesign® industryHeradesign® microHeradesign® planoHeradesign® fine/A2

Heradesign® superfineHeradesign® fineHeradesign® microHeradesign® fineHeradesign® micro

Heradesign® fine 25 mmHeradesign® micro 25 mm

Heradesign® fineHeradesign® micro

Heradesign®

Heradesign® fine superfine, naturalHeradesign® fine, natural

Heradesign® fineHeradesign® microMagnesite bonded

EU:FIW Munichofi-Bauinstitut, ViennaMA 39, Vienna

CH Vereinigung KantonalerFeuerversicherungen,Berne

F CSTB CENTRE SCIENTI-FIQUE ET TECHNIQUEDU BATIMENT, Paris

D Materialprüfungsamt für das Bauwesen der Techn. Universität München

E LABORATORI GENERALD‘ASSAIGS I INVESTIGA-CIONS, Barcelona

DK Dansk Brandteknisk Institut, Hoidovre

GB Warrington Fire Research Centre

I Ministerio dell’ Interno, Roma

NL SKH, Huizen

EC conformity certificateReg. No.K1-0751-CPD-290.0-02-01/05

No Z 14032 No Z 10972No Z 10973RA00-269

Certificateof complianceNr. 1245-2002

98.01197198.011970

PF 11507CP 00127148480148479

On request

KOMO attest Nr. 20609/05

CE marking of the products.as per EN 13168Building material class B-s1, d0as per EN 13501-1

Building material class A2-s1, d0as per EN 13501-1BKZ 6q.3BKZ 6q.3BKZ 6q.3Classement au feu: M1 *)

B1 flame resistant(as per DIN 4102, Part 1)

ignífugo M1as per UNE 23.727-90 *)

Material: Class Abeklædning: Class 1 *)Fire propagation index I = 7.8Fire propagation index = 7.1as per BS 476: Part 6Omologazione Class 1 *)

KOMO certified

19.11.200319.11.200319.11.200313.06.2000

26.03.2002

23.06.199623.06.1996

22.07.200318.04.200424.08.200523.09.2005

2005

Test item Country/Test Institute Certificate No. Date Results

Page 145: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

145

Other Test Data

EN ISO 9001 TÜV / CERT Quality management system

Chloride content of Herakustik panels according to ÖN EN 13168Termite resistance

Formaldehyde emission

Building biology properties Heradesign® fineHeradesign® fine/A2Heradesign® starHeradesign® micro(all coloured white)

Indoor Climate Level Test Heradesign® fine

B1 Quality over time (with high shooting intensity in the shoo-ting gallery)

D Certification centre of the Rhine Westphalia TÜV

A Ofi Bauinstitut Vienna

SA Department of Forestry, Forest research Institute

RI Regional Centre for Research On Human Settlements, Bandung

A Austrian Wood Research Institute

D Institute for Building Biology + Ecology Neubeuern

DK Danish Society for Indoor Climate, Danish Technolo-gical Institute, Taastrup

D FMPABaden-Württemberg

Certificateregistration no. 0410020040231

200.056

F.P. 4114

332/87

Building biology certificate

Indoor Climate Level Test Certificate No. 056

16-78591

Requirements of EN ISO 9001complied with

Class Cl 3 ( 0,06 M-%)

„... after 5 1/2 years of exposure the Heraklith ... specimens had been slightly attacked by termites.““Termite resistant”

no formaldehyde emissions

“Building biology sound products”Magnesite bonded fine woolly

Wood wool acoustic panels are approved for the “Danish Product Quality Seal for the Indoor Climate“

Requirement of B1 as perDIN 4102 complied with

10.02.2004

12.05.2003

07.07.1964

25.11.1991

03.06.1987

09.08.200430.03.2005

16.08.2004

10.09.1990

Test item Land/Prüfanstalt Gutachten Nr. Datum Ergebnis

Page 146: Heradesign Technical Manual - RIBA Product Selector · *) Heradesign® fine and Heradesign® superfine are only available in the format 600/600 or alternatively 625/625 for a thickness

All particulars made without obligation; subject to changes and misprints. Graphics: www.die1ns.com, 06/2008

A business unit of Knauf Insulation GmbH – Fürnitz Austria

Heradesign Ceilings DivisionA-9702 Ferndorf 29, AustriaPhone: +43/4245/2001-3003Fax: +43/4245/2001-3499E-mail: [email protected] w w . h e r a d e s i g n . a t