hercules impact-resistant panels · hercules panel will remain looking fresh and intact. this...
TRANSCRIPT
ENGINEERING DATA SHEET
P r i m a c o u s t i c i s a d i v i s i o n o f R a d i a l E n g i n e e r i n g L t d . • 1 5 8 8 K e b e t Wa y P o r t C o q u i t l a m , B C V 3 C 5 M 5 • Te l : 6 0 4 - 9 4 2 - 1 0 0 1 F a x : 6 0 4 - 9 4 2 - 1 0 1 0www.primacoustic.com • [email protected] • Primacoustic Engineering Data Sheet • Part #R870 2200 00 • Copyright © 2016 • Subject to change without notice.
HERCULESIMPACT-RESISTANT PANELS
Primacoustic Hercules™ panels are absorption panels that are designed to withstand the abuse of environments such as gymnasiums, offi ces, classrooms, and other public occupancy spaces. While most acoustic panels are delicate and susceptible to damage, Hercules will help to reduce reverberation while looking like new after repeated impact.
Hercules impact-resistant panels are manufactured from the same high-density (6pcf/96kg/m3) glass wool core as Primacoustic Broadway panels, but the face of the panel is covered with a rigid fi berglass layer. This facing allows the panel to effectively absorb most frequencies, but the protection will prevent damage occurring from accidental contact. Whether someone bumps into the panel, or a basketball bounces off it in a gymnasium, the Hercules panel will remain looking fresh and intact. This durable facing even allows for the use of thumbtacks in the panel, making it ideal for offi ce spaces or schools.
Hercules panels measure 24”x48”x2” (60x120x5cm) with square edges, and are available in beige or grey acoustically transparent fabric.
100H
z
125H
z
160H
z
200H
z
250H
z
315H
z
400H
z
500H
z
630H
z
800H
z
1kH
z
1.25
kHz
1.6k
Hz
2kH
z
2.5k
Hz
3.15
kHz
4kH
z
5kH
z
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
FREQUENCY (Hz)
SOU
ND
AB
SOR
PTIO
N C
OEF
FIC
IEN
T
2” Panel
* Testing performed by Riverbank Acoustical Laboratories. The test method conform explicitly with the requirements of the ASTM Standard Test Method for Sound Absorption and Sound Absorption Coeffi cients by the Reverberation Room Method: ASTM C 423-02a and E795-05.
PANEL DEPTH 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz NRC
2” (51mm) Depth 0.58 0.82 1.50 1.00 0.97 0.95 0.98
ABSORPTION CHARACTERISTICS:*Sound absorption coeffi cient data
APPLICATION:
PRODUCT RANGE:
FIRE & BURN PERFORMANCE:COUNTRY TEST STANDARD CLASSIFICATION
USA ASTM E84-17 Class A/1
ORDER NO.* Thickness Color Weight / per QTY
F202-2448-03 2” (51mm) Beige 8.3 lbs / 3.8 kg 6
F202-2448-08 2” (51mm) Grey 8.3 lbs / 3.8 kg 6
CORE MATERIAL DENSITY Formed, semi-rigid inorganic glass fi bers, 6.0 lbs pcf (96 kg/m3)
FABRIC FACING Rigid acoustically transparent polyester
BACKING Glass wool tissue micromesh
EDGE TREATMENT Sealed and hardened with resin
RECYCLED CONTENT Up to 40%
LEED ELIGIBLE Yes
SPECIFICATIONS: