Hg System Status
V.B. Graves
P.T. Spampinato
Muon Collaboration Friday Meeting
October 20, 2006
![Page 2: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/2.jpg)
2MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Initial Water Testing Setup
A primary containment has been mocked up to allow initial water tests to be performed
Will be used to debug Labview control software and test some of the sensors
Remainder of syringe hardware scheduled for delivery week of Oct 23
![Page 3: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/3.jpg)
3MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Control System Connections
Most internal Labview wiring completed
Temporary wiring for sensors required for testing
Remainder to be completed upon delivery of wiring pkg from Princeton
At last review
Current wiring
![Page 4: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/4.jpg)
4MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Syringe Pump Performance Testing
Control system development complete based on water tests Minor modifications may be required after switch to Hg, but none are
expected Data logging incorporated
System can produce a 20m/s, 1cm-dia water jet Water test nozzle configuration approximately matches one of the two Hg
nozzles My opinion: jet quality looks good for a no-field condition. Holds together for
better than ~1/2m
![Page 5: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/5.jpg)
5MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Water Test 20m/s Screenshot
![Page 6: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/6.jpg)
6MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Load Testing of Common Baseplate & Target Cart
CERN Safety Commission voiced concerns regarding analysis performed on common baseplate design
Load test performed on structures to verify strength and test adjusting mechanisms
Estimated component weights Magnet: 12000 lbs (5440 kg) Hg system (with 23liters Hg): 4000 lbs (1810 kg)
Test weights Magnet: 13600 lbs (6170 kg) = 113% estimated weight Hg system: 4500 lbs (2040 kg) = 113% estimated weight
![Page 7: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/7.jpg)
7MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
In Nominal Test Position Baseplate tilt ~ 66mrad
Elevation matches CAD models
![Page 8: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/8.jpg)
8MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Operational Testing
Lifting jacks and lateral position adjustment mechanisms tested
![Page 9: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/9.jpg)
9MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Roller Testing
Loaded baseplate pushed with pallet jack while on three Hilman rollers
![Page 10: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/10.jpg)
10MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Leveling Jack Testing
Baseplate adequately supported by four leveling jacks
![Page 11: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/11.jpg)
11MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Conclusions
Syringe pump control system development completed
System can produce 20m/s water jet within pump's performance limits No reason to think Hg will be different
MERIT common baseplate has been successfully tested with 113% expected loading
Final assembly and optics integration to commence shortly
Switch to Hg will be made once all operational aspects of system have been tested with water
![Page 12: Hg System Status V.B. Graves P.T. Spampinato Muon Collaboration Friday Meeting October 20, 2006](https://reader036.vdocument.in/reader036/viewer/2022081520/56649d4c5503460f94a298d5/html5/thumbnails/12.jpg)
12MC Friday Meeting 20 Oct 2006
OAK RIDGE NATIONAL LABORATORYU. S. DEPARTMENT OF ENERGY
Conclusions
Manual control of syringe demonstrated
Hydraulic system fill and drain procedures developed
Hg control system wiring is underway, water tests to start afterwards
Ready for Hg testing after conclusion of water tests and when remainder of fabricated components available