hi-lamp_hi-bay_bruchure_rev4-21-15
TRANSCRIPT
DEG-325400 DEG-600750 DEG-450550
None of the wasted resources and all of the light you could possibly use.(and — Made in the U.S.A.! )
DIFFERENTIAL ENERGY GLOBAL LTD., Delivering Energy-savings Globally 1540 Leader International Drive • Port Orchard, WA 98367-6437
www.degLED.com • www.theleader.com • 800-635-8188 • 360-895-1184
A DIFFERENT APPROACHyet very much the same...it’s just a light bulb!
A SIMPLE, REPLACEABLE LAMP FOR LOW/HIGH BAY HID BULBS - SCREWS DIRECTLY INTO EXISTINGMOGUL BASE RECEPTACLES WITH EXCEPTIONALLY HIGH LIGHT OUTPUT COMPARED TO COMPETITIVEPRODUCTS (250W-1,000W Equivalent). AN ADDITIONAL BENEFIT IS THE BUILT-IN DE-STRATIFICATION
FOR MOST HIGH CEILING INSTALLATIONS AND IS AVAILABLE WITH A CUSTOM MICRO-PRISM LENS.10-YEAR (prorated) WARRANTY
LED HI-LAMPS70w-400w Replacement Lamps for HID Bulbs
A low-cost, high ROI replacement alternative to costly LED retrofit assemblies and kits for HID low/high bay fixtures.
LED HI-BAYS250w-1,000w Replacement Lamps for HID Bulbs
All lamps shown below with Micro-Prism Lens
DEG-250400 DEG-250400 w/light control wings
DEG-150175 DEG-070120 w/mogul base DEG-070120 w/medium base
IECEE 62471Photobiological Safety IEC 62560:2011
General Lighting
9-7/8"250.83mm
HI-LAMP DEG-250400(INTERTEK DEG-250300)
1lb. 14.1oz.0.85 kg.
4-3/8"111.13mm 3"
76.20mm
3-3/4"45.25mm
SpecificationsMODEL DEG-250400INPUT POWER (WATTS) 111HID EQUIVALENT SYSTEM POWER (WATTS) 450INPUT LINE VOLTAGE (VAC) 110-277INPUT FREQUENCY (Hz) 50-60BASE TYPE MOGULLUMENS 8,938LUMEN EFFICACY (LPW) 80.74CCT 4500KCRI 75CALCULATED LIFETIME (L70 HOURS @ 85°C) 84,100POWER FACTOR @ 120 VAC 0.983NUMBER OF LED’S 15LED TYPE CREE XM-L2WARRANTY 5 year Non-Prorated + 5 year Limited
HI-LAMP DEG-150175SHOWN WITH TYPE lll LENS
1lb. 6.7oz.0.64kg.
8-3/4"222.25mm
3-1/8"79.38mm
4-3/8"111.13mm
3-3/4"45.25mm
SpecificationsMODEL DEG-150175INPUT POWER (WATTS) 58HID EQUIVALENT SYSTEM POWER (WATTS) 200INPUT LINE VOLTAGE (VAC) 110-277INPUT FREQUENCY (Hz) 50-60BASE TYPE MOGULLUMENS 4,585LUMEN EFFICACY (LPW) 78CCT 4500KCRI 76CALCULATED LIFETIME (L70 HOURS @ 55°C) 183,000POWER FACTOR @ 120 VAC 0.93NUMBER OF LED’S 8LED TYPE CREE XM-L2WARRANTY 5 year Non-Prorated + 5 year Limited
Note: When installing LED HI-Lamp to replace HID bulb, ballast must be removed and recycled when present. Eliminating the ballast saves additional costs related to maintenance, energy consumption and performance and may be required by code. It is recommended that an in-line surge protection device such as the TRP-FSP3-277-20KA be installed for all non-self-ballasted outdoor applications.
PROPRIETARY NOTICE: THIS DOCUMENT CONTAINS DIFFERENTIAL ENERGY GLOBAL, LTD. PROPRIETARY INFORMATION. COPYRIGHT AND DESIGN RIGHTS ARISING FROM THIS DOCUMENT ARE THE EXCLUSIVE PROPERTY OF DEG, LTD. REPRODUCTION OF ALL OR PART OF THIS DOCUMENT, EITHER DIRECTLY OR INDIRECTLY, OR ITS DISCLOSURE TO ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN CONSENT OF DEG, LTD. IS STRICTLY PROHIBITED. UTILITY AND DESIGN PATENTS PENDING.
5-5/16"134.94mm
2-3/8"60.33mm
2-11/16"68.26mm
HI-LAMP DEG-0701207.4oz.0.21kg.
The HI-LAMP DEG-070100has a very compact in-lineLED Driver (power supply.)Available in E-26 E-27 mediumbase and E-39 E-40 mogulbase.
SpecificationsMODEL (NEW REV AVAILABLE MAY 2015) DEG-070120INPUT POWER (WATTS) 19HID EQUIVALENT SYSTEM POWER (WATTS) UP TO 132INPUT LINE VOLTAGE (VAC) 110-277INPUT FREQUENCY (Hz) 50-60BASE TYPE MEDIUM OR MOGUL LUMENS 1,982LUMEN EFFICACY (LPW) 106.6CCT 4500KCRI 75CALCULATED LIFETIME (L70 HOURS @ 70°C) 100,000+POWER FACTOR @ 120 VAC 0.965NUMBER OF LED’S 4LED TYPE CREE XM-L2WARRANTY 5 year Non-Prorated + 5 year Limited
• Direct Replacement for HID Bulbs - Triac-Dimmable • Fully rotational 360° adjustment assists with Dark Sky cut-off requirements • No modification required to conventional fully-enclosed luminaire fixtures • For use in enclosed fixtures, even IP66 & IP67 (UL 1993 Self-Ballasted Lamp) • Simply bypass conventional ballast - Remove/Recycle for additional ROI • Retain current fixtures – No need for costly replacements (UL 1598C - LED Conversion)• Compatible with line voltages up to 277 VAC with no modification (50/60 Hz) • Thermal Safety Feature/bypass circuitry ensures long operating life • Thermal Safety Protection Fuse• LED Module easily disconnects from Driver Module for easy repair/replacement• In-line surge protection device such as the TRP-FSP3-277-20KA is required.
• Direct Replacement for HID Bulbs - Triac-Dimmable • Fully rotational 360° adjustment assists with Dark Sky cut-off requirements • No modification required to conventional fully-enclosed luminaire fixtures • For use in enclosed fixtures, even IP66 & IP67 (UL 1993 Self-Ballasted Lamp) • Simply bypass conventional ballast - Remove/Recycle for additional ROI • Retain current fixtures – No need for costly replacements (UL 1598C - LED Conversion) • Compatible with line voltages up to 277 VAC with no modification (50/60 Hz) • Thermal Safety Feature/bypass circuitry ensures long operating life • Thermal Safety Protection Fuse • LED Module easily disconnects from Driver Module for easy repair/replacement• In-line surge protection device such as the TRP-FSP3-277-20KA is required.
• Direct Replacement for HID Bulbs• Fully rotational 360° adjustment assists with Dark Sky cut-off requirements• No modification required to conventional fully-enclosed luminaire fixtures• For use in enclosed fixtures, even IP66 & IP67• Simply bypass conventional ballast - Remove/Recycle for additional ROI• Retain current fixtures – No need for costly replacements (UL1598C - LED Conversion)• Small Compact direct replacement LED lamp for 70-120w HPS/MH bulbs
• Parking Lot • Parking Garages • Walkways • Warehouses • Retail Box Stores • Fueling Stations • Wallpacks • Residential and Street lighting
TYPE II, III & V Optics or Flat Clear Lens w/Adjustable Light Control Wings
OUTDOOR and COMMERCIAL / INDUSTRIAL APPLICATIONS
• Parking Lot • Parking Garages • Walkways • Warehouses • Retail Box Stores • Fueling Stations • Wallpacks • Residential and Street lighting
TYPE II, III & V Optics or Micro-Prism Flat or Curved Lens
OUTDOOR and COMMERCIAL / INDUSTRIAL APPLICATIONS
• Parking Lot • Parking Garages • Walkways • Warehouse Side Doors • Canopy Lights • Fueling Stations • Wallpacks • Park/Entry Lighting
This LED Lamp requires an inline LED Driver.
OUTDOOR and COMMERCIAL / INDUSTRIAL APPLICATIONS
IECEE 62471Photobiological Safety IEC 62560:2011
General Lighting
IEC 62560:2011 General Lighting
IECEE 62471Photobiological Safety
IECEE 62471Photobiological Safety IEC 62560:2011
General Lighting
• New In-line high-efficiency power supply with PFC replaces energy-wasting ballast• Simply bypass conventional ballast - Remove/Recycle for additional ROI• Direct Replacement for HID Bulbs and is 0-10 VDC dimmable (within Standard Dimming Protocols) • Fits all conventional high-bay luminaire fixtures with no modification to fixture• Retain current fixtures – No need for costly replacements (UL 1598C - LED Conversion)• Selectable Output Level on each LED HI-Bay to customize lighting levels• Compatible with line voltages up to 277 VAC with no modification (50/60 Hz)• Active Thermal Management circuitry ensures long operating life• Thermal Safety Protection Fuse• It is recommended that an in-line surge protection device such as the TRP-FSP3-277-20KA be installed on HI-Bay lamps.• For exterior HI-Bay lamp installation surge protection is required.
INDOOR COMMERCIAL / INDUSTRIAL INSTITUTIONAL APPLICATIONS
HI-Bay Series LED Replacement Lamps for High/Low Bay HID Applications
*For additional Color Temperatures, greater CRI please contact our sales and engineering team.**The Bonneville Power Administration (BPA) has reviewed and approved the mogul based LED’s submitted by DEG and is currently accepting them and offering incentives through the non-residential lighting program.The DEG-325400, DEG-450550 and DEG-600750 are LDL listed.
The LED HI-Bay is a direct replacement LED Lamp for E39/E40mogul base HID bulbs in most indoor low/high bay fixtures.
Available in Standard 4500K - Best Combinationof Brightness for Security and Spectral Contentfor Accurate Color Representation. Other Color Temps Available*70 - 100 Lumens per Watt (CREE XLamp, XM-L2)(Depending on Light Level Output setting)75 - 80 CRI*UL/CSA/CE ● LM79, LM80, TM21 LDL & Bonneville Power Administration (BPA)**
• Warehouses • Parking Garages• Industrial Buildings • Retail Box Stores• Fueling Stations • Gymnasiums • Sports Complexes • Large Auditoriums• Correction Facilities
Note: Light output can be dialed downward via a user-accessible screw-adjustment, with resulting power savings and increased efficiency. Specifications shown for maximum output level, except Input Power (Watts) which shows min/max levels.
SpecificationsMODEL DEG-600750INPUT POWER (WATTS) 314HID EQUIVALENT SYSTEM POWER (WATTS) 1,000INPUT LINE VOLTAGE (VAC) 110-277INPUT FREQUENCY (Hz) 50-60BASE TYPE MOGULLUMENS 22,303LUMEN EFFICACY (LPW) 71CCT 4500KCRI 76CALCULATED LIFETIME (L70 HOURS @ 85°C) 138,000POWER FACTOR @ 120 VAC 0.991NUMBER OF LED’S 42LED TYPE CREE XM-L2WARRANTY 5 year Non-Prorated + 5 year Limited
HI-BAY DEG-600750SHOWN WITHOUT LENS
2lb. 5.6oz.1.07kg
Located HereLED Driver
7-1/4"184.15mm
6"152.40mm
Selectable Lumen Range
Adjustable to 22,303 max
SystemWatts
14-314 14w= 0 light
Compare to HID System Watts
up to 1,000* *spacing and height dependent
SpecificationsMODEL DEG-450550INPUT POWER (WATTS) 231HID EQUIVALENT SYSTEM POWER (WATTS) 600INPUT LINE VOLTAGE (VAC) 110-277INPUT FREQUENCY (Hz) 50-60BASE TYPE MOGULLUMENS 16,849LUMEN EFFICACY (LPW) 73CCT 4500KCRI 75CALCULATED LIFETIME (L70 HOURS @ 85°C) 100,000+POWER FACTOR @ 120 VAC 0.99NUMBER OF LED’S 30LED TYPE CREE XM-L2WARRANTY 5 year Non-Prorated + 5 year Limited
7-1/4"184.15mm
5-3/8"136.53mm
HI-BAY DEG-450550SHOWN WITHOUT LENS
2lb. 4.2oz.1.03kg.
Located HereLED Driver
Selectable Lumen Range
Adjustable to 16,849 max
SystemWatts
14-231 14w= 0 light
Compare to HID System Watts
up to 600
SpecificationsMODEL DEG-325400INPUT POWER (WATTS) 156HID EQUIVALENT SYSTEM POWER (WATTS) 450INPUT LINE VOLTAGE (VAC) 110-277INPUT FREQUENCY (Hz) 50-60BASE TYPE MOGULLUMENS 11,665LUMEN EFFICACY (LPW) 75CCT 4500KCRI 78CALCULATED LIFETIME (L70 HOURS @ 85°C) 100,000+ POWER FACTOR @ 120 VAC 0.996 NUMBER OF LED’S 20LED TYPE CREE XM-L2WARRANTY 5 year Non-Prorated + 5 year Limited
7-1/4"184.15mm
4-1/2"114.30mm
HI-BAY DEG-325400SHOWN WITHOUT LENS
1lb. 9.5oz.0.72kg.
Located HereLED Driver
Selectable Lumen Range
Adjustable to 11,665 max
SystemWatts
14-156 14w= 0 light
Compare to HID System Watts
up to 450
SYSTEM WITH APPROVED POWER SUPPLY CONFORMS TO: FCC/CISPR 22:2008 Class A. Conducted and Radiated Emissions
Note: When installing LED HI-Bay to replace HID bulb, ballast must be removed and recycled when present and the DEG approved AC/DC power supply installed in its place. Eliminating the ballast saves additional costs related to maintenance, energy consumption and performance and may be required by code.
AC TO 48VDC POWER SUPPLY
IECEE 62471Photobiological Safety IEC 62560:2011
General Lighting
It is recommended that an in-line surge protection device
such as the TRP-FSP3-277-20KA be installed the CLiK.• For exterior CLiK installation surge protection is required.
INDOOR or OUTDOOR COMMERCIAL /INDUSTRIAL or INSTITUTIONAL
APPLICATIONS
CLiK & Oclipse LED Replacement Lamp for HID & Specialty Fixture Applications
t
Available in Standard 4000K
Note:
LEA-SYSTEM WITH APPROVED POWER SUPPLY CONFORMS TO: FCC/CISPR 22:2008 Class A. Conducted and Radiated Emissions
Note: the CLiK or Oclipse to rep
pr its
osts
IECEE 62471Photobiological Safety
IEC 62560:2011General Lighting
CLIK DEG-100225-W
Note:
PROPRIETARY NOTICE:
CliK DEG-100225
Note: r
PROPRIETARY NOTICE:
CLIK DEG-100225-N
Specificatio
ns Estimated
DRAFT ONLY
Universal MountA Patent Pending Design
Differential Energy Global Ltd. 1540 Leader International Drive • Port Orchard, WA 98367-6437 • 800-635-8188 • www.differentialenergy.com
HI-LAMP OPTICS
TYPE II TYPE III TYPE V
DEG products are not designed for Hot-Plugging – Don’t install any DEG Lamp with power ON, or ‘hot’, as it will result in voltage and current spikes that will damage the equipment and nullify the product warranty.
An over-voltage event occurs when the input AC voltage is in excess of the 277VAC limit allowed for by our power supplies (i.e.: 480VAC single phase line input) while the latter event occurs when a product is connected to a “hot” input line during installation, or a lamp is screwed into an energized or “hot” socket. In the case of DEG products if the power is ON—or Hot—when the lamps are screwed into the “hot” mogul or medium base socket (“Hot-Plugging”), this can cause a power surge and create an over-voltage event and failure of the electronics. The over-voltage event is generally much more catastrophic and obvious in determining the root cause as the voltage regulator and fuse will fail. All electrical and mechanical connections associated WITH INSTALLATION OF DEG PRODUCTS MUST BE MADE IN A MANNER THAT PREVENTS INSTALLATION OF LAMPS IN ALREADY-ENERGIZED CIRCUITS. Other components in the system must be designed so that the removal of a hot-pluggable component does not interrupt operation of the lamp or damage components. DEG’s products are not designed for removal and replacement of the lamp while the power is ‘hot’ [still ON with socket empty] and therefore the electrical input power must be turned off. Once the DEG lamp is installed in the mogul or medium socket the electrical input can be switched ON and the lamp will safely operate.
DIALING IT ALL IN WITH DIMMING AND POTENTIOMETER CONTROLS
Many of DEG’s LED products have a range of features that most current LED lamps, retro-fit kits and full head or light standard replacements do not offer. Never before has a direct replacement LED light source offered so many features and benefits in controlling light output, spread, dimming and a host of other features.
From the initial concept of our replacement LED lamps for HID bulbs we sought to innovate as many usable features as possible to elevate the control of light output. While most of these early conceptual ideas were focused on distribution patterns, cut-off features and dimming to gain lower wattage use, we also incorporated a unique approach to controlling heat (our patent-pending Air Flo-Thru Thermal System) and preventing a catastrophic over-heating failure by incorporating a thermal fuse. The HID EQUIV chart and comparisons are approximate values. A full light output evaluation (fixture spacing, fc/Lux readings, CRI, customer preference/satisfaction, test installation, etc.) should be made to determine proper replacement of LED lamps for HID bulbs.
DEG-600750, DEG-450550 & DEG-325400 LED HI-Bay lamps
The LED HI-Bay lamps all incorporate two very unique features to control the level of light output:
Dimming on the HI-Bay lamps is achieved using a 0-10 VDC analog signal supplied by two wires as per the ANSI E1.3 dimming protocol, not the current-sinking DALI protocol. It is the responsibility of the end user to determine the suitability of the product for an application and the interface requirements for dimming functionality.
The features allow for the greatest range in setting the desired light output and simultaneously lowering the overall wattage being used to operate the LED lamps—particularly if the full light output is not needed.
rev1.5 3-02-15
1) a potentiometer that rotates right to left as shown at right(marked by ‘4’ being the highest light output and ‘0’ being the lowest light output or zero) and,
2) a 0-10 VDC dimming control. The TOP level of 0-10 VDCrange is set by establishing the top end of the potentiometer. For instance, if ‘2’ is set on the potentiometer then the0-10VDC dimming range will have as its top-end range thelight output setting of ‘2’ on the potentiometer and ‘0’ (or no light output) to ‘0’ on the bottom end of the 0-10VDC range.
DIFFERENTIAL ENERGY GLOBAL LTD. Installation Fixture Criteria Worksheet
1
2
3
4
5
6
A FEW IMPORTANT CONSIDERATIONS TO INSURE THE CHANGE TO LED IS SUCCESSFUL7
8
9
10
11
12 All pole fixtures require an in-line surge protection device such as the TRP-FSP3-277-20KA.
THANK YOU FOR CONSIDERING OUR PRODUCTS! DEG Rev 4.17.15
Name: ____________________________
Form-factor Space: 1.________________________ 2.____________________________3.______________________ 4._____________________ 5.____________________________
The "form-factor" or interior area from approximate center of mogul base receptor and approximate diameter or area circumference around the receptor and then from outermost edge of mogul base receptor to outermost inner wall of fixture…in other words, what is the space you have to work with as far as type of HI-Lamp to be placed in fixture? In "inches" or "mm".
Is fixture "sealed" and a rated IP65/66 fixture? Is the gasket in good to excellent condition or worn and fractured, cracking and the rubber fragmented and falling apart? Replace if necessary.
We require that all ballast system components be completely removed and recycled. Some utilities require this as part of their rebate program but others do not--WE DO.
Knowing the spacing between fixtures (exterior or interior fixtures) will help indentify the correct fc/lux replacement. Distance (in ft or mm): 1._________________ 2.________________3.______________________ 4._____________________ 5.____________________________
Distance (in ft or mm): 1.________________________ 2.____________________________
DATE: __________________Company: _________________________
Cover Type: 1.________________________ 2.____________________________
LIST LED LAMP TYPE(s): 1._______________________ 2.____________________________3.______________________ 4._____________________ 5.____________________________
If you are unsure that the fixture is right for a DEG HI-Lamp or HI-Bay, sending a picture of the full outside and inside of the fixture will help DEG guide you so insure one of DEG's lamps is the correct product. You may also wish to write down the fixture type (mfg.), style, HID bulb rating for the fixture, UL rating label inside fixture housing (IP rating), voltage rating (if labeled) and email to DEG. DO NOT place DEG's LED Lamps into any exterior open bottom or wet location
Knowing the distance in feet from ground to bottom of glass cover of fixture (whether a Cobrahead, wall pack or shoebox and low or high bay) will help indentify the correct lamp
We will need the HI-Lamp, HI-Bay proper lamp designation, which is acceptable in two ways: 4, 8, 15-LED HI-Lamp -and-- 20, 30, 42-LED HI-Bay ---OR--- 070100 (4-LED); 150175 (8-LED),
3.______________________ 4._____________________ 5.____________________________
TO ASSIST YOU WITH YOUR PROJECT LIGHTING DECISION:
3.______________________ 4._____________________ 5.____________________________
Input Voltage: 1.________________________ 2.____________________________3.______________________ 4._____________________ 5.____________________________
If you plan on utilizing the 0-10VDC incorporated into the LED HI-Bay be sure to signify this so that we can configure the instructions on best method to connect and wire this feature.
Lens Cover type: Fresnel, prismatic, plastic, glass, clear, sag or flat lens style. This will help DEG identify the correct Optical lens type or Micro-prism lens for the type of fixture cover lens.
To help DEG identify the correct power supply needed for HI-Bay lamps and 070120 HI-Lamp--Line voltage IN and if 480v, 2 phase or 3 phase, or 347v . (DEG lamp range is 120v-277v)
3.______________________ 4._____________________ 5.____________________________
NOTE: This is a worksheet to help the purchaser of our products insure that the correct product(s) are specified and purchased.
Use it as a tool for your projects in LED lamp selection.
It would be helpful in knowing the type of fixture the particular LED HI-Lamp or HI-Bay lamp will be placed into--logging this will help us identify any issues with installation you may encounter. LIST FIXTURE TYPE(s): 1.________________________ 2.____________________________
IN CHOOSING THE CORRECT REPLACEMENT LED LIGHTING SOLUTIONBELOW ARE A FEW OF THE CRITICAL ITEMS TO BE AWARE OF…
HI-Lamp_HI-Bay_bruchure4-21-15