high frequency radiography x-ray systems...genware service software documentation radiographic high...

2
GENUINE X-RAY & RADIOLOGICAL EQUIPMENTS PVT. LTD. Plot No. 3, Radhe Industrial Estate, Block No. 497 (P), Tajpur Road, Sarkhej - Bavla Road, Changodar, Ta. Sanand, Ahmedabad - 382 213. Gujarat, India Phone : +91 - 2717 - 298934 E-mail : Website : genuinexray@rediffmail.com [email protected] www. genuinexray.com REVOLUTION IN RADIOLOGY ROOM Dimensions as per AERB Guidelines - L 4.5 x B 4.0 x H 2.75 meters. All Machine Design / Technical Specificaons shown in catalogue are subject to change without any prior noce as standard procedure and constant improvement. Chest Stand Control Unit Table Centre Column Center Tube Column Stand 277 cm X- Ray Examination Room All Dimensions are in cm Double Leaf Door lined with 2 mm lead. 235 cm X-Ray Tube Head MPB With Lead Glass viewing Window of 2.0 mm Lead equivalence Examination Table Unit Electronics Unit Electronics SALIENT FEATURES 32kW, 40kW, 50kW, 65kW & 80kW HIGH FREQUENCY RADIOGRAPHY X-RAY SYSTEMS Cost effective for all Radiographic applications (Hospitals, Medical Clinics, Chiropractic and Veterinary applications) Field upgradable for your Future Imaging requirements. Small, Compact & Light Weight. Anatomical Programs available in many languages that are easily edited by the Operator Membrane Control Console. Technique Selection : 1. kV with AEC 2. kV / mAs 3. kV / mA / Time 4. Patient / Body Part Thickness (Membrane Control Console) Low kV ripple - maximizes image quality by providing constant potential performance. Automatic Tube Calibration Service Software allows fast and easy set up as well as system diagnostics for off-site analysis Collimator Power Supply CONTROL PANEL GOVERNMENT OF INDIA AERB APPROVED IS:7620 PART-1 CM/L - 3950571 REVOLUTION IN RADIOLOGY Certified & Approved by : CLINICAL OUTPUT 400 cm 450 cm All wall of the Examination Room are 23 cm (9”) thick made of bricks. Autho. Dealer :

Upload: others

Post on 26-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • GENUINE X-RAY & RADIOLOGICALEQUIPMENTS PVT. LTD.

    Plot No. 3, Radhe Industrial Estate, Block No. 497 (P),Tajpur Road, Sarkhej - Bavla Road, Changodar, Ta. Sanand,Ahmedabad - 382 213. Gujarat, IndiaPhone : +91 - 2717 - 298934

    E-mail :

    Website :

    [email protected]@genuinexray.com

    www. genuinexray.com

    REVOLUTION IN RADIOLOGY

    ROOM Dimensions as per AERB Guidelines - L 4.5 x B 4.0 x H 2.75 meters.

    All Machine Design / Technical Specifica�ons shown in catalogue are subject to change without any prior no�ce as standard procedure and constant improvement.

    Chest

    Stand

    ControlUnit

    Table Centre

    Column Center

    Tube ColumnStand

    277

    cm

    X- Ray Examination Room

    All Dimensions are in cm

    Dou

    ble

    Leaf

    Doo

    rlin

    ed w

    ith 2

    mm

    lead

    .

    235 cm

    X-RayTube Head

    MPB With Lead Glassviewing Window of 2.0mm Lead equivalence

    ExaminationTable

    UnitElectronicsUnitElectronics

    SALIENT FEATURES

    32kW, 40kW, 50kW, 65kW & 80kW

    HIGH FREQUENCYRADIOGRAPHY X-RAY SYSTEMS

    Cost effective for all Radiographic applications (Hospitals, Medical Clinics, Chiropractic and Veterinary applications)

    Field upgradable for your Future Imaging requirements.

    Small, Compact & Light Weight.

    Anatomical Programs available in many languages that are easily edited by the Operator Membrane Control Console.

    Technique Selection :

    1. kV with AEC

    2. kV / mAs

    3. kV / mA / Time

    4. Patient / Body Part Thickness

    (Membrane Control Console)

    Low kV ripple - maximizes image quality by providing constant potential performance.

    Automatic Tube Calibration

    Service Software allows fast and easy set up as well as system diagnostics for off-site analysis

    Collimator Power Supply

    CONTROL PANEL

    GOVERNMENT OF INDIA

    AERB APPROVEDIS:7620

    PART-1CM/L - 3950571 REVOLUTION IN RADIOLOGY

    Certified & Approved by :

    CLINICAL OUTPUT

    400 cm

    450 cm

    All wall of the Examination Roomare 23 cm (9”) thick made of bricks.

    Autho. Dealer :

  • with Horizontal Bucky Table

    with 5- Position Bucky Table

    BASIC RADIOGRAPHY SYSTEM

    ULTRA RADIOGRAPHY SYSTEM

    with 4- Way Floating Bucky Table

    SMART RADIOGRAPHY SYSTEM

    HF Generator Series offers advanced high quality Radiographic capabilities with unmatched performance and reliability resulting in the lowest cost of ownership over the product lifetime. This Generator is suitable for Film and CR - Based Radiographic systems and features leading edge micro-processor based controls to minimize patient doze and maximize image quality while demonstrating excellent reproducibility with user-friendly operator controls.

    TECHNOLOGY

    All Radiography Systems come with Floor to Ceiling Column Tube Stand fully counter balanced.

    Optional Ceiling Free Column Tube Stand available on demand. Vertical Bucky Control Unit Control Panel

    X - Ray Tube

    H.V. Cable

    OPTIONALX- RAY GENERATOR

    HIGH FREQUENCY RADIOGRAPHY X-RAY SYSTEMS

    GXL- HF 32 kW / GXL HF 40kW / GXL HF 50 kW / GXL HF 65kW / GXL HF 80 kW

    TECHNICAL SPECIFICATION

    CMP 200 MODELS 32 kW 40 kW 50 kW 65 kW 80 kW

    Application

    Generator Type

    kVp Range

    mA Range

    mAs Range (non - AEC)

    Rotor Supply

    Input Phase / Voltage

    High Voltage Ripple

    Compatible X-Ray Tubes

    Auto-Tube Calibration

    Exposure Timer Range

    Anatomical Programs (APR)

    Supported Console Languages

    Image Receptors

    Technique Selection

    Tomography Mode

    Auxiliary Collimator Power Supply

    GenWare Service Software

    Documentation

    Radiographic

    High Frequency Output (Maximum 400 kHz)

    40-125 kV (150 kV optional - 3 only)Ф 40-150 kV

    10-400 mA

    0.1-500 mAs

    1Ф/208-230 VAC

    3Ф/208-230 VAC (150 kV optional

    with External Transformer)

    3Ф/400-480 VAC (150 kV optional)

    3Ф/208-230 VAC (External Transformer

    required for 65 kW)

    3Ф/400-480 VAC

    0.1-630 mAs

    Low Speed Starter (Optional Dual Speed Starter)

    0.1-800 mAs 0.1-1000 mAs

    10-500 mA 10-630 mA 10-800 mA 10-1000 mA

    3Ф/400-480 VAC

    300 tube models

    Standard Feature

    Maximum 6.3 s standard ( 10 s, 20 s, or 30 s optional )

    1024 / 20,000 + techniques

    English, French, German, Italian, Spanish, Swedish, Cyrillic (additional available on request)

    Up to 5

    kV / AEC, kV / mAs, kV / mA / ms or kV / cm thickness (requires standard console)

    Standard Feature

    Standard Feature

    PC - based diagnostic and technical support

    Manuals on CD (hard copy optional)

    Page 1Page 2