High gradient test results from X-BOX1

Ben WoolleyWilfrid Farabolini

MevArc, ChamonixNovember 2013

Page 2: High gradient test results from X-BOX1

RF Processing of CLIC Structures• High accelerating gradient 100MV/m

200-300MV/m surface fields.

• Long conditioning period needed >2000hrs to reduce breakdown rate toward 3x10-7 for CLIC.

• The established method: – Start with short pulse length (50ns).– Ramp to nominal power(100MV/m,

~42MW) keeping BDR~10-5.– Increase pulse length by 50ns, drop

gradient by ~10% and repeat.

A. Grudiev, W. Wuensch, CERN

Page 3: High gradient test results from X-BOX1

Gallery

Bunker

Clockwise from top-left:• Modulator/klystron

(50MW, 1.5us pulse)• Pulse compressor

(250ns, ratio 2.8)• DUT + connections• Acc. structure (TD26CC)

Xbox-1 Layout

Page 4: High gradient test results from X-BOX1

System Layout and diagnostics

Page 5: High gradient test results from X-BOX1

Accelerating Structure Diagnostics

CLIC Accelerating StructureRF Hybrid

RF Load RF Load

RF Load

Asymmetric Reflection

Incident power

Reflected Power

Transmitted Power

Ion gauge readout

Ion gauge readout

50 dB directional coupler

Upstream Faraday cup signal

Downstream Faraday cup signal

RF Power From Klystron

WR90 Waveguide

Input coupler Output coupler

Beam-pipe Beam-pipe

Page 6: High gradient test results from X-BOX1

Accelerating Structure DiagnosticsFaraday CupDirectional coupler Ion Gauge

Structure output couplers

RF Load

Structure input couplers

Temperature probe

RF hybrid splitter(behind metal support)

Ion Pump

Vacuum valveIon Gauge

Page 7: High gradient test results from X-BOX1

Operator display

Page 8: High gradient test results from X-BOX1

BD Detection: Normal Pulse

• Transmitted pulse follows the incident pulse but with ~4dB of attenuation.

• Reflected signal is ~20dB lower than incident pulse.

• Only a few mV seen on the faraday cups. DC2-Upstream sees 1/10 of the signal compared to downstream.

500 1000 1500 2000 2500 30000

10

20

30

40

Slow RF Power signals

Time [ns]

Pow

er [M

W]

INTRA rescaledREF

0 500 1000 1500 2000 2500 3000 3500-15

-10

-5

0

5x 10

-3 Slow FC signals

Time [ns]

FC v

olta

ge [V

/50o

hm]

DC1DC2

Page 9: High gradient test results from X-BOX1

BD Detection: Breakdown• Transmitted pulse drops as the

arc is established.• Reflected power increases to

the same order as the incident pulse.

• Faraday cup voltages are saturated: 100-1000x increase in charge emitted.

• We can use the difference in time between the transmitted power falling and the reflected power increasing to find the BD cell location.

• The phase of the reflected signal is used to pinpoint cell location.

Wilfrid Farabolini

Page 10: High gradient test results from X-BOX1

Breakdown: Steps taken

• We stop the next pulse from occurring and wait 2 seconds to let the vacuum level recover.

• All the signals are logged to file for later analysis.

• Over 20-30 seconds we ramp the power from zero back to the power set-point.

Page 11: High gradient test results from X-BOX1

Cavity Conditioning Algorithm

• Automatically controls incident power to structure.

• Short term: +10kW steps every 6 min and -10kW per BD event.

• Long Term: Measures BDR (1MPulse moving avg.) and will stop power increase if BDR too high.

Page 12: High gradient test results from X-BOX1

Results: TD26CC

Page 13: High gradient test results from X-BOX1

#785

~200 ns

Page 14: High gradient test results from X-BOX1

Wilfrid Farabolini

Results: TD26CC BD Location

Corrupted files and no powered periods have been removed from the record

Page 15: High gradient test results from X-BOX1

Wilfrid Farabolini

Results: TD24R05 BD Location

Cells nb.Records nb.

Hot cells (5 and 6) have appeared from record #50The very high peak values are an artifact of the normalization (if only 2 BDs during a record these cells will result very active)

Page 16: High gradient test results from X-BOX1

Wilfrid Farabolini

Initial Phase Measurements• We expect to see reflected

phase grouped into 3 bins separated by 120°. Need more data to reaffirm this.

• Accurate reflected phase measurement should take into account the incident phase fluctuation.

• About 25% of BDs see a drift in position:

– REF pulse is split in 2 parts that shows 2 different phases

– Phase drifts about 240o from raising edge to peak REF (1st and 2nd REF pulses).

– The drift is always negative BD arc is moving towards the input.

Page 17: High gradient test results from X-BOX1

Results: TD26CC UP-TIME

Uptime~75%

Re-Calibration of signal paths>1week

Page 18: High gradient test results from X-BOX1

Results: TD26CC UP-TIME

Klystron gun arcs cause high vacuum for 20-50hrs

Page 19: High gradient test results from X-BOX1

Xbox-1: Future Developments

• Try to solve the issue with the klystron arcs.

• Continue to develop phase measurement analysis.– Increase accuracy.– BD cell locations.– BD drifts.

• Dynamic range on DC measurements to be increased along with faster sampling. (Use logarithmic amplifier or split signal in two with low and high dynamic ranges respectively.)

• Soon to have installation of dark current energy spectrometer Should give better indication of the energies involved in accelerating electrons and ions during a BD.

• Quicker/better method of calibration to be devised (less downtime).

19

Page 20: High gradient test results from X-BOX1

Thank you for your attention!

Page 21: High gradient test results from X-BOX1

Extra Slides

Page 22: High gradient test results from X-BOX1

Summary• Phase signals are opening a very interesting new field of investigations • Still some improvements in signal acquisition to be performed• Many BDs show REF phase drifts (more or less by steps of 120o and 240o):

BD#: 1-2-5-7-13-15-17-20-34-35• These BDs are mainly associated to location drift from BD ignition to BD

extinction• Some stable location BDs are mainly associate with no RF drifts, BD#: 8-9-

18-26• When REF phase drifts it is always decreasing • INC phase is also affected after a BD, this effect is to be subtracted from

the measured REF phase• New BD diagnostics would help in BD evolution understanding (optical or

RF plasma probes)

Page 23: High gradient test results from X-BOX1

Future LLRF Generation and Acquisition for X-band test stands

IF2.4 GHz Oscillator

9.6GHz BPF

Amp

Vector Modulator

RFout

LOin LOout

12GHz vector modulated

signal to DUT

2.9 GHz Oscillator

X4 freq.

RF

LO

LOIF RF

12 GHz BPF

12 GHz BPF

12GHz CW reference

signal

2.4GHz vector modulated

signal

2.4GHz CW reference signal

11.6 GHz BPF

X4 freq.

LO

IF

RF Input 1

400 MHzLPFs

LO

IF

RF Input 2

LO

IF

RF Input 3

LO

IF

RF_Referance12GHz CW reference

signal

3dB hybrid

AmpIF Amps

Oscillators should be phase locked

1.6 GSPS

12-bit ADCs

Digital IQ demodulation