184
5 (5.8)8 (9.2)8 (9.2)
16 (18.4)16 (18.4)25 (28.8)25 (28.8)36 (41.5)36 (41.5)50 (57.7)50 (57.7)64 (73.8)64 (73.8)80 (92.3)80 (92.3)110 (127)110 (127)180 (207)180 (207)280 (323)280 (323)
Current ratingsat 40ºC (25º)
A
Filter
12 1.6 0.17 2 -7.6 1.6 0.17 2 -7.6 1.6 0.17 2 -5.2 3.4 0.17 1.5 -5.2 3.3 0.17 1.5 -2.2 4.4 1.8 1.5 1.12.2 3.3 2 1.5 1.11.3 4.4 1.8 1.5 1.11.3 3.3 2 1.5 1.10.8 4.4 2 1.5 1.10.8 3.3 2 1.5 1.10.65 4.4 2 1.5 1.10.65 3.3 2 1.5 1.10.85 6.7 2.2 1.5 1.10.85 6.1 2.2 1.5 1.10.5 6.7 2.2 1.5 1.10.5 6.1 2.2 1.5 1.10.5 5 2.2 1.5 1.10.5 5 2.2 1.5 1.10.3 10 2.6 1.5 1.10.3 10 2.6 1.5 1.1
†Max. leakage under normal circumstances. Note: if two phases are interrupted, worst case leakage current could reach 7.6 times (5A to 16A types) or 6.0 times (25A to 280A types)higher levels. Measured at: standard types 400VAC; H types 520VAC.
Component values/phase
L ∑Cx ∑Cy R1 R2mH µF µF MΩ MΩ
Powerloss
W
Weight
kg
Leakage current†IEC 1000-2-4
mA at 50Hz
Phaseconnections
1.11.81.61.81.63
1.63
1.63.11.63.31.89.59.59.59.513132828
Electrical schematicSee table for component values
L3
R2Cy Cy
R1CxCx L
FN 351
L2
L1
L3’
L2’
L1’
E E’
Mechanical data
Technical specifications
Maximum operating voltage: 440VAC at 40ºC for standard types; 520VAC at 40ºC for H types
Hipot test voltage: standard: PÇ E 2600VDC; P Ç P 1900VDC; H: P Ç E 2800VDC, P Ç P 2300VDC
MTBF at 40°C, 400V per Mil-HB-217F: 135,000 hours standard types, 100,000 hours H types (at 500 V)
Protection category: IP20; Operating frequency: DC to 60 Hz
Overload: 4 times rated current at switch on, then 1.5 times rated current for 1 minute, once per hour
All dimensions in mm; 1 inch = 25.4mm
LINE LOAD
up to 110Aup to 110Aup to 110A
FN 351 - 5 / ??FN 351 - 8 / ??FN351H - 8 / ??FN 351 - 16 / ??FN351H - 16 / ??FN 351 - 25 / ??FN351H - 25 / ??FN 351 - 36 / ??FN351H - 36 / ??FN 351 - 50 / ??FN351H - 50 / ??FN 351 - 64 / ??FN351H - 64 / ??FN 351 - 80 / ??FN351H - 80 / ??FN 351 - 110 / ??FN351H - 110 / ??FN 351 - 180 / ??FN351H - 180 / ??FN 351 - 280 / ??FN351H - 280 / ??
1.91.92.51.92.528.035.428.035.429.635.429.635.431.841.331.841.331.340.735.846.5
/29/29/29
/29 /46/29
/33 /46/33
/33 /47/33
/33 /34 /47 /52/33 /34
/33 /34 /47 /52/33/34/34/35/35/36/36/37/37
677888899111115152323252549497070
†for connections /34 and /52 only* Measurements share this common tolerance unless otherwise stated
FN 351
• 5 to 280A current ratings, 440V and 520V versions• high differential/common mode attenuation• IEC 950 compliant
• Nennströme von 5 bis 280A; 440V und 520V Versionen• Hohe differentielle/Gleichtakt-Dämpfung• IEC 950 konform
• courants de service de 5 à 280A, versions pour 440V et 520V• bonne atténuation en modes symétrique et asymétrique• conforme à CEI 950
High-power filter
H-types up to 110AC US
Approvals
†
185
FN 351 insertion loss
Per CISPR 17; A = 50Ω/50Ω sym, B = 50Ω/50Ω asym, C = 0.1Ω/100Ω sym, D = 100Ω/0.1Ω sym
16 amp types 25 amp types8 amp types
50 amp types 80 amp types64 amp types
180 amp types
5 amp types
36 amp types
110 amp types 280 amp types
FRONT
FN 351-5, -8, -16, -25, -36, -50, -64/29 connections shown FN 351-80, -110
D
D
M
C
G
C
GK
K
P
E EA A
H
HF
F
B
B
M
NTOP
FN 351-180, -280
G
M
P
N
FB
Q
D
H
EA
KC
Mechanical drawings
See mechanical data table for dimensions
P
174
Three-phasefilters
175
Three-phase filters
CONTENTS
General information
Filter selection chart............................. 176
Ordering information ............................ 177
Technical data
Three-phase filters
FN 258............................................ 180
FN 3258.......................................... 182
FN 351............................................ 184
FN 3359.......................................... 186
FN 3100/FN 3110........................... 188
Three-phase + neutral filters
FN 256............................................ 192
FN 354............................................ 194
FN 355............................................ 196
FN 356............................................ 198
INHALT
Allgemeine Informationen
Filterübersicht....................................... 176
Bestellinformationen ............................ 177
Technische Daten
Dreiphasen-Filter
FN 258............................................ 180
FN 3258.......................................... 182
FN 351............................................ 184
FN 3359.......................................... 186
FN 3100/FN 3110........................... 188
Dreiphasen + Neutralleiter-Filter
FN 256............................................ 192
FN 354............................................ 194
FN 355............................................ 196
FN 356............................................ 198
TABLE DES MATIÈRES
Généralités
Tableau de sélection des filtres........... 176
Pour commander.................................. 177
Données techniques
Filtres triphasés
FN 258............................................ 180
FN 3258.......................................... 182
FN 351............................................ 184
FN 3359.......................................... 186
FN 3100/FN 3110........................... 188
Filtres triphasés et neutres
FN 256............................................ 192
FN 354............................................ 194
FN 355............................................ 196
FN 356............................................ 198
Family
FN 256 192
FN 258 180
FN 3258 182
FN 351 184
FN 354 194
FN 355 196
FN 356 198
FN 3100/ 188
FN 3110
176
0 20 40 60 80 100 120 140 160 180 200
0 2 4 6 8 10
standard
Current rating [A]Insertion loss
medium high very high
over
2-st
age
Saf
ety
term
inal
Thr
ee p
hase
s
Thr
ee p
hase
s +
N
Fo
r fr
eque
ncy
inve
rter
s
Cat
alo
g p
age
Family
FN 3359 186
0 400 800 1200 1600 2000 2400 2800
0 2 4 6 8 10
standard
Current rating [A]
Insertion loss
medium high very high 3-st
age
Saf
ety
term
inal
Thr
ee p
hase
s
Thr
ee p
hase
s +
N
Fo
r fr
eque
ncy
inve
rter
s
Cat
alo
g p
age
For currents up to 300A
For high currents
Schaffner’s 3-phase chassis-mounting filter rangeRapid selection Using the current rating and attenuation performance indicators, together with the major features shown on the
right, this table allows you to quickly identify a ‘short list’ of filter families which are potentially suitable for your application, for subsequent detailed investigation using the technical specifications on the following pages.
Time to marketThe key reasons for choosing ready-made three-phase filters are convenience and cost. Althoughyou can design your own filter using discretecomponents, or have a custom solutiondesigned and assembled for you, the timescalesinvolved - especially if safety approvals arerequired - invariably rule this approach out. Theavailability of off-the-shelf filters is particularlyimportant to industrial users and systemcommissioning personnel, who often requirenext-day delivery of fit-and-forget EMC solutionssimply to meet contractual obligations or toavoid incurring penalty clauses.
Ready-made filters provide a convenient single-source solution. The following guide toSchaffner’s three-phase products - with briefdetails on key parameters - will help you toidentify one or more filters for closer review ofspecifications. From this initial selection, a review of the circuit diagram and detailedspecifications in the following pages will tell youif the module is suitable for your application,allowing you to choose a unit (or units) for trial. Schaffner’s applicationengineers, based in numerous sales outletsaround the world, are available to provide in-depth advice if you require it.
General technical information
Insertion lossThe insertion loss characteristics of the filtersare measured in accordance with the CISPR 17
standard. Two test conditions are specified inSection 4.2 of the CISPR 17 standard, namelyinput and output impedances of 50/50Ω and0.1/100Ω.
In general, three-phase filters perform the samein the face of differential interference as in the50Ω insertion loss test. In order to show theperformance under realistic conditions,Schaffner also shows the attenuation curvesobtained from the 0.1/100Ω test, which are moremeaningful for common mode interference. Theinductance of the chokes used in the filters canchange under load because of a saturationeffect, which can also affect insertion loss.
Flammability classificationAll the filters in this catalog comply with therequirements of UL 94V2 or UL 94V0.
Climatic classificationSchaffner three-phase filters comply with theclimatic classification 25/085/21 according toDIN IEC 68 Part 1 (ambient temperature -25 to+85˚C) or 25/100/21 (+ 100 °C).
Component tolerancesParameter - Tol. + Tol. TestInductance 30% 50% 1kHzCapacitance 20% 20% 1kHzResistance 10% 10% DC
Current ratingsThe nominal currents stated refer to an ambienttemperature of £N = 40˚C or £N = 50˚C. Themaximum operating current at any other ambienttemperature £ can be calculated by means of thefollowing formula:
I = IN P (85 - £)/(85 - £N)
Leakage current
Operational conditionsThe values given in the technical filterspecifications are based on IEC 1000-2-4,section 5.5, and the following conditions:nominal voltage 440VAC for standard types,520VAC for H types, 690VAC for HV types;nominal frequency 50Hz; tolerance ofcapacitance ± 20%; unsymmetrical input voltage ± 3%.
Worst case conditionsWorst case conditions are based on theassumption that two of the three lines weredisconnected. For the calculation of the leakagecurrent the voltage of one phase towards theground UP^E 50Hz is used; capacitancetolerance ± 20%.
The values calculated under worst caseconditions are equal to the valuescorresponding to the operational conditionson standard Japanese networks. In the caseof a network with a neutral line, the valuescorresponding to the European operationalconditions are equal to the Japaneseoperational conditions with a neutral line.
177
For all three-phase filters
FN 258 & - x / youtput connections 03 = clamp terminal with M4 screw
05 = AMP fast-on06 = solder-lug/fast-on combination07 = wire24 = screw lead - through M628 = screw lead - through M1029 = terminal block33 = terminal block34 = terminal block35 = terminal block36 = terminal block37 = terminal block40 = terminal block45 = strip terminal block46 = strip terminal block47 = strip terminal block52 = strip terminal block99 = busbar connections
current rating (A)
H = high voltageHV = very high voltageHVIT = designed for 690 VAC IT - networksP = medium leakage currentL = low leakage current
filter type
for details see page 235
Examples:FN 351H-50/33 Type FN 351H (high voltage); current rating 50A; with safety terminal block connections FN 258L-55/07 Type FN 258L (low leakage current); current rating 55A; with wire output connectionsFN 3359-1600/99 Type FN 3359; current rating 1600 A; with busbar connections
Ordering information