hilti hud-l universal anchor

7

Click here to load reader

Upload: paulo-pinto

Post on 04-Dec-2015

46 views

Category:

Documents


6 download

DESCRIPTION

Hilti HUD-L Universal Anchor

TRANSCRIPT

Page 1: Hilti HUD-L Universal Anchor

HUD-L Universal anchor

Hilti (Gt. Britain) Limited,

1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY

Telephone:

0800 886 100

HILTI HUD-L Universal anchor

The enclosed pages are taken from the Hilti Fastening Technology Manual

Edition September 2012 For further details including details of product European Technical Approvals, Guidance on product selection and detailed design assistance please contact

Hilti (Gt Britain) Ltd Technical Advisory Service.

Hilti (Gt Britain) Ltd

TECHNICAL ADVISORY SERVICE

Telephone 0161 886 1144

Email [email protected]

Quality Management Approvals ISO 9001: 2008 Quality Management System Certified by: The Swiss Association for Quality and Management Systems. Registration No: 12455 Valid until 30th June 2013 Scope No: 18, Machinery and Equipment. Note: Under our accreditation with SQS the scope of accreditation is not contained within an appendix but is stated as Scope 18 on the SQS Certificate. Scope No. 18 is Machinery and Equipment.”

Page 2: Hilti HUD-L Universal Anchor

HUD-L Universal anchor

Hilti (Gt. Britain) Limited,

1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY

Telephone:

0800 886 100

Important notice 1. Construction materials and conditions vary on different sites. If it is suspected that the base material has insufficient strength to achieve a suitable fastening, contact the Hilti Technical Advisory Service. 2. The information and recommendations given herein are based on the principles, formulae and safety factors set out in the Hilti technical instructions, the operating manuals, the setting instructions, the installation manuals and other data sheets that are believed to be correct at the time of writing. The data and values are based on the respective average values obtained from tests under laboratory or other controlled conditions. It is the users responsibility to use the data given in the light of conditions on site and taking into account the intended use of the products concerned. The user has to check the listed prerequisites and criteria conform with the conditions actually existing on the job-site. Whilst Hilti can give general guidance and advice, the nature of Hilti products means that the ultimate responsibility for selecting the right product for a particular application must lie with the customer. 3. All products must be used, handled and applied strictly in accordance with all current instructions for use published by Hilti, i.e. technical instructions, operating manuals, setting instructions, installation manuals and others. 4. All products are supplied and advice is given subject to the Hilti terms of business. 5. Hilti´s policy is one of continuous development. We therefore reserve the right to alter specifications, etc. without notice. 6. The given mean ultimate loads and characteristic data in the Anchor Fastening Technology Manual reflect actual test results and are thus valid only for the indicated test conditions. Due to variations in local base materials, on-site testing is required to determine performance at any specific site. 7. Hilti is not obligated for direct, indirect, incidental or consequential damages, losses or expenses in connection with, or by reason of, the use of, or inability to use the products for any purpose. Implied warranties of merchantability or fitness for a particular purpose are specifically excluded. Hilti Corporation FL-9494 Schaan Principality of Liechtenstein www.hilti.com

Page 3: Hilti HUD-L Universal Anchor

HUD-L Universal anchor

Hilti (Gt. Britain) Limited,

1 Trafford Wharf Road, Trafford Park, Manchester M17 1BY

Telephone:

0800 886 100

Visit our web site at www.Hilti.co.uk/technical to access our comprehensive technical support services

Design and Specification

Profis Anchor Software

Technical Library

Access our comprehensive engineering support, including the Anchor Design and Firestop Design Centres

Profis Anchor 2.1 is the latest Hilti software, designed to assist planners and specifiers to select the required anchors for your applications.

Download the latest technical documents (approvals, test reports, etc.) and software (PROFIS Anchor).

Hilti (Gt. Britain) Ltd is a member of the Construction Fixings Association.

Page 4: Hilti HUD-L Universal Anchor

HUD-L Universal anchor

09 / 2012 262

���������� ����������Anchor version Benefits

HUD-L 6 HUD-L 8

HUD-L 10

- universal plastic anchor for weak base materials and renovation

- for many base materials - daily application - excellent setting behaviour

� � � �

� � � �

�������� ��� ������� ��������������������� �

����� ���������

�������� � � � �

Basic loading data (for a single anchor) All data in this section applies to- Correct setting (See setting instruction) - Load data are only valid for the specified woodscrew type - Load data given in the tables is independent of load direction - No edge distance and spacing influence - Base material as specified in the table - Minimum base material thickness

Characteristic resistanceAnchor size HUD-L 6x50 HUD-L 8x60 HUD-L 10x70

Screw type c) Woodscrew 4,5x80 DIN 96

Woodscrew 5x90 DIN 96

Woodscrew 8mm DIN 571

Concrete � C16/20 FRk [kN] 1,15 1,4 9,0

Solid clay brick Mz 12 FRk [kN] 0,85 1,0 -

Solid clay brick Mz 20 FRk [kN] - - 7,0

Solid sand-lime brick KS 12 FRk [kN] 0,85 1,0 2

Hollow clay brick Hlz 12 a) FRk [kN] 0,5 0,75 1,5

Hollow sand-lime brick KSL 12 FRk [kN] 0,7 0,8 -

Autoclaved aerated concreteAAC 2 a) FRk [kN] 0,25 0,55 2,0

Gypsum board Thickness 2x12,5mm a) FRk [kN] 0,3 0,7 0,6 b)

a) Drilling without hammering b) Suitable for fitting hexagonal screws by hand c) Load data are valid for the mentioned woodscrew type, if other types or different screws are used the load

capacity may decrease.

Page 5: Hilti HUD-L Universal Anchor

HUD-L Universal anchor

09 / 2012 263

Design resistanceAnchor size HUD-L 6x50 HUD-L 8x60 HUD-L 10x70

Screw type c) Woodscrew 4,5x80 DIN 96

Woodscrew 5x90 DIN 96

Woodscrew 8mm DIN 571

Concrete � C16/20 FRd [kN] 0,32 0,39 2,52

Solid clay brick Mz 12 FRd [kN] 0,24 0,28 -

Solid clay brick Mz 20 FRd [kN] - - 1,96

Solid sand-lime brick KS 12 FRd [kN] 0,24 0,28 0,56

Hollow clay brick Hlz 12 a) FRd [kN] 0,14 0,21 0,42

Hollow sand-lime brick KSL 12 FRd [kN] 0,20 0,22 -

Autoclaved aerated concreteAAC 2 a) FRd [kN] 0,07 0,15 0,56

Gypsum board Thickness 2x12,5mm a) FRd [kN] 0,08 0,20 0,17 b)

a) Drilling without hammering b) Suitable for fitting hexagonal screws by hand c) Load data are valid for the mentioned woodscrew type, if other types or different screws are used the load

capacity may decrease.

Recommended loads d)

Anchor size HUD-L 6x50 HUD-L 8x60 HUD-L 10x70

Screw type c) Woodscrew 4,5x80 DIN 96

Woodscrew 5x90 DIN 96

Woodscrew 8mm DIN 571

Concrete � C16/20 Frec [kN] 0,23 0,28 1,8

Solid clay brick Mz 12 Frec [kN] 0,17 0,2 -

Solid clay brick Mz 20 Frec [kN] - - 1,4

Solid sand-lime brick KS 12 Frec [kN] 0,17 0,2 0,4

Hollow clay brick Hlz 12 a) Frec [kN] 0,1 0,15 0,3

Hollow sand-lime brick KSL 12 Frec [kN] 0,14 0,16 -

Autoclaved aerated concreteAAC 2 a) Frec [kN] 0,05 0,11 0,4

Gypsum board Thickness 2x12,5mm a) Frec [kN] 0,06 0,14 0,12 b)

a) Drilling without hammering b) Suitable for fitting hexagonal screws by hand c) Load data are valid for the mentioned woodscrew type, if other types or different screws are used the load

capacity may decrease. d) With overall global safety factor � = 5 to the characteristic loads and a partial safety factor of � = 1,4 to the

design values.

Page 6: Hilti HUD-L Universal Anchor

HUD-L Universal anchor

09 / 2012 264

Service temperature range Hilti HUD-L universal anchor may be applied in the temperature range given below.

Temperature range Base material temperature

Maximum long term base material temperature

Maximum short term base material temperature

Temperature range -40 °C to +80 °C +50 °C +80 °C

Max short term base material temperature Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of diurnal cycling.

Max long term base material temperature Long-term elevated base material temperatures are roughly constant over significant periods of time.

MaterialsMaterial qualityPart Material Plastic sleeve Polyamide 6

Setting Installation equipmentAnchor size HUD-L

6x50 HUD-L 8x60

HUD-L 10x70

Rotary hammer TE 2 – TE 16 Other tools Screwdriver

Setting instruction

Use only for wall and floor applications. Not applicable for ceiling and façade applications.

For detailed information on installation see instruction for use given with the package of the product.

Page 7: Hilti HUD-L Universal Anchor

HUD-L Universal anchor

09 / 2012 265

Setting details: depth of drill hole h1 and effective anchorage depth hef

Setting details HUD-LAnchor version HUD-L

HUD-L 6x50

HUD-L 8x60

HUD-L 10x70

Nominal diameter of drill bit do [mm] 6 8 10

Cutting diameter of drill bit dcut � [mm] 6,4 8,45 10,45

Depth of drill hole h1 � [mm] 70 80 90

Effective anchorage depth hnom [mm] 47 57 70

Anchor length l [mm] 47 57 70

Max fixture thickness tfix [mm] Depending on screw length Installation temperature [°C] -10 to +40

Recommended length of screw in base material ld [mm] 55 65 75

Woodscrew diameter a) d [mm] 4,5 - 5 5 - 6 7 - 8a) The basic loading data are depending on the woodscrew diameters, if other types or different screws are

used the load capacity may decrease. Highlighted diameters refer to basic loading data table.