hipath 3000 5000 v9 getting started issue 4

28
Siemens Enterprise Communications www.siemens-enterprise.com Documentation HiPath 3000/5000 V9 IP Systems Getting Started  A31003-H3590-G100- 4-7631

Upload: sorin-birou

Post on 07-Aug-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 1/28Siemens Enterprise Communicationswww siemens-enterprise com

DocumentationHiPath 3000/5000 V9IP Systems

Getting Started

 A31003-H3590-G100-4-7631

Page 2: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 2/28

Our Quality and Environmental ManagementSystems are implemented according to the

requirements of the ISO9001 and ISO14001 standard

certified by an external certification company.

Copyright © Siemens Enterprise

Communications GmbH & Co. KG 10/2011Hofmannstr. 51, D-80200 München

Siemens Enterprise Communications GmbH & Co.

KG is a Trademark Licensee of Siemens AG

Reference No.: A31003-H3590-G100-4-7631

The information provided in this document contains

merely general descriptions or characteristics of

performance which in case of actual use do not always

apply as described or which may change as a result of

further development of the products. An obligation to

provide the respective characteristics shall only exist if

expressly agreed in the terms of contract.  Availability

and technical specifications are subject to change

without notice.

OpenScape, OpenStage and HiPath are registered

trademarks of Siemens Enterprise

Communications GmbH & Co. KG.

 All other company, brand, product and service names

are trademarks or registered trademarks of theirSiemens Enterprise Communicationswww.siemens-enterprise.com

Page 3: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 3/28

GetstartedTOC.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 0-1

Nur für den internen Gebrauch Contents

Contents 0

1 Basics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.1 Target Group and Use of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11.2 Varieties of the HiPath 3000/5000 IP System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

1.2.1 HiPath 3000 V9 IP System (Standalone) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21.2.2 HiPath 3000 V9 Networked IP Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3

1.3 Typographical Conventions and Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-41.4 Further Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5

2 Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

3 HiPath 3000/5000 V9 IP Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13.1 Step by Step Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13.2 Installing the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13.3 Installing Additional HiPath 3000 Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23.4 Initial Startup of HiPath 3000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33.5 Connecting the HiPath 3000 to the LAN via the HG 1500. . . . . . . . . . . . . . . . . . . . . . 3-43.6 Initial Configuration of the HiPath 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73.7 Licensing the Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-93.8 Configuring the IP Clients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-113.9 Further Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-143.10 Connection to the Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14

Index  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z-1

Page 4: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 4/28

Contents Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

0-2 HiPath 3000/5000 V9, Getting Started

GetstartedTOC.fm

Page 5: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 5/28

intro.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 1-1

Nur für den internen Gebrauch Basics

Target Group and Use of this Manual 

1 Basics

1.1 Target Group and Use of this Manual

This document contains brief installation and startup instructions for a HiPath system or network.It is intended for technically advanced customers who want to perform the initial startup of theirHiPath 3000/5000 IP system themselves, and configure the basic Internet telephony features.In addition, it is a useful aid for trained service personnel who want a brief overview of the chro-nological sequence of startup activities.

1.2 Varieties of the HiPath 3000/5000 IP System

HiPath 3000/5000 V9 is a highly scalable communications system designed for both small and

medium-sized companies as well as for extensive enterprise networks. HiPath 3000/5000 V9is available in a wide range of configurations – from straightforward standalone systems with asmall number of stations to centrally administered networks with 64 nodes and up to 2000workpoint clients (IP and TDM telephones and IP clients). The system architecture avails of theadvantages of distributed systems to spread the load placed on individual components and toachieve optimal performance.

HiPath 3000/5000 V9 is available in the following three varieties:

● HiPath 3000 V9 IP System (Standalone)

● HiPath 3000 V9 Networked IP Systems

>A general introduction to the HiPath 3000/5000 V9 family of products can be found● in the System Description and● in the Service ManualThese documents also contain detailed information on system installation and star-tup.

Page 6: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 6/28

Basics Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

1-2 HiPath 3000/5000 V9, Getting Started

intro.fm

Varieties of the HiPath 3000/5000 IP System 

1.2.1 HiPath 3000 V9 IP System (Standalone)

This variant allows the mixed operation of analog terminals, UP0/E terminals (OpenStage TDMrange), IP-based terminals (OpenStage CorNet-IP (HFA) range) and IP clients (OpenScape

UC Application).

LAN/IP

IP telephones:

OpenStage CorNet-IP (HFA) rangeOpenScape UC Application

(OpenScape Personal Edition)

HiPath 3000 V9including HG 1500

HiPath Cordless Office

Administration PC for HiPath

3000 incl. applications, e.g.:● Manager E/C

● HiPath Fault Management

● HiPath QoS Management● ... UP0/E telephones:

OpenStage TDM range

PSTN/ISDN

Fax, analog telephones

Page 7: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 7/28

intro.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 1-3 

Nur für den internen Gebrauch Basics

Varieties of the HiPath 3000/5000 IP System 

1.2.2 HiPath 3000 V9 Networked IP Systems

This variant is networked using several HiPath 3000 nodes networked via IP and allows amixed operation of analog terminals, UP0/E terminals (OpenStage TDM range), IP-based termi-

nals (OpenStage CorNet-IP (HFA) range) and IP clients (OpenScape UC Application).

OpenScape UC Application(OpenScape Personal Edition)

LAN/IP

IP telephones:

OpenStage CorNet-IP (HFA) range

HiPath 3000 V9including HG 1500

HiPath Cordless Office

UP0/E telephones:

OpenStage TDM range

PSTN/ISDN

Fax, analog telephones

Administration PC for HiPath3000 incl. applications, e.g.:

● Manager E/C● HiPath Fault Management

● HiPath QoS Management

● ...

HiPath 3000 V9including HG 1500

HiPath Cordless Office

UP0/E telephones:

OpenStage TDM range

PSTN/ISDN

Fax, analog telephones

Page 8: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 8/28

Basics Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

1-4 HiPath 3000/5000 V9, Getting Started

intro.fm

Typographical Conventions and Symbols Used 

1.3 Typographical Conventions and Symbols Used

... the OK button ... Buttons and menus are shown in bold type. Body text that is

especially important or should be read carefully is also for-matted in bold.

... file global.cfg ... Files or directories appear in Courier font.

<wildcard> Entries or information, which can vary depending on the situationat hand, appear in angle brackets.

>This symbol indicates notes or recommendations.

7This symbol indicates warnings that must be observed.

Page 9: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 9/28

intro.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 1-5 

Nur für den internen Gebrauch Basics

Further Information 

1.4 Further Information

Further information on HiPath 3000/5000 V9 is provided in the following documents:

Feature DescriptionThe Feature Description lists and describes in detail all HiPath 3000 and HiPath 5000 fea-tures, grouped according to topic. Dependencies with other features and possible restric-tions are also described.

● Service Manual

The service manual provides information on systems corresponding to HiPath 3000/5000.The information provided includes descriptions of all HiPath 3000-compatible boards, in-formation on standard installation and startup procedures for the various HiPath 3000 sys-tems, startup and administration of HiPath 5000 RSM, information on HiPath License Man-

agement and details of the workpoint clients supported.● Manager E Administrator Documentation

With HiPath 3000 Manager, you can administrate and configure HiPath 3000 and HiPath5000 communication systems. You can manage either a standalone communication sys-tem or a network comprising several HiPath 3000 and HiPath 5000 communication sys-tems by configuring the corresponding customer data memory (CDM). With netwide ad-ministration you can access and modify the central customer data memory from a centrallocation in the network (e.g. configure, modify or relocate stations).

● HG 1500 Administrator Documentation

These instructions provide a complete description of the administration options offered byHG 1500. They explain clearly and concisely how to administer and configure a gatewayvia the Web-Based Management (WBM) interface.

Page 10: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 10/28

Basics Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

1-6 HiPath 3000/5000 V9, Getting Started

intro.fm

Further Information 

● Inventory Manager User Guide

With the Inventory Manager, you can quickly obtain a complete overview of all integratedcomponents and installed applications in the HiPath 3000/5000 V9 network. For service

technicians, the quick, concise overview which can be called up for the version numbers ofall communication servers in the network (HiPath 3000 and HiPath 5000) can be particu-larly useful. The information can be accessed from every PC in the network.

The following information can be called up:

 – Information on all HiPath 3000 and HiPath 5000 systems in the network, including in-formation on their respective boards (e.g. HG 1500),

 – Information on all applications and operating systems installed on the PCs in the net-work,

 – Display of the hierarchical structure of hardware components and their software ver-sions.

● Software Manager User Guide

With the Software Manager you can query, update and back up the current system soft-ware for individual HiPath components via a web browser. The assignment of the HiPathcomponents to the individual nodes can also be quickly ascertained. The functions are dis-tributed as follows:

 – with the integrated Upgrade Manager you can query and update the system software

of all HiPath components, – with the integrated Backup Manager you can back up the system software. These back-

ups can then be used to restore the systems in the event of a system crash.

Page 11: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 11/28

allg_Hinweise.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 2-1

Nur für den internen Gebrauch Preparations

2 Preparations

The following points must be clarified and carried out before HiPath 3000 installation and initial

setup. Cross references to the associated documentation provide further details. If you havethese instructions in electronic form, click the blue links and you will be branched to the corre-sponding documentation.

 Subject Description Detailed infor-mation

Safety notes Please pay attention to the relevant safety information on install-ing, upgrading and initial setup.

HiPath 3000 Ser-vice Manual, Chap-ter Safety Notes

Delivery docu-

ments

Compare items delivered with the units listed in the delivery doc-

uments.Completeness/ integrity

Test unit integrity.Are there signs of transport damage?

Installation siteconditions

Does the installation site meet all necessary requirements interms of surroundings and power supply?

HiPath 3000 Ser-vice Manual, Chap-ter HiPath 3000 In-stallation

Licensing Is all the licensing data for any networked HiPath 3000 systemsavailable, such as the authorization code and the MAC address(MAC-ID) for all HiPath 3000 Control Boards (CB)?Is all of the licensing data for a HiPath 3000/5000 network avail-able, such as the authorization code and the MAC address (MACID) of the first HiPath 3000 Control Board (CB) with the lowestnode ID?Is there Internet access for licensing?Is there a license file available for each HiPath 3000 and is it in-stalled correctly in the CLA (Customer License Agent)? You onlyneed one license file for networked HiPath 3000 systems with Hi-Path 5000. The license files and access to the license server areprovided via License Management.Note:The licensing period is 30 days. The relevant features must be li-

censed within this time.

Requirementsspecification,licensing docu-ments

HiPath 3000 Ser-vice Manual, Li-censing Chapter

License serverURL:https://www.sie-mens.com/license-management

requirementsspecification

Is the requirements specification agreed with the customer avail-able and does it contain all the necessary data?Is further information required?

See requirementsspecification

Numbering plan Has a numbering plan been developed in line with customer re-quirements?

Refer to the re-quirements specifi-cations if neces-sary

Page 12: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 12/28

Preparations Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

2-2 HiPath 3000/5000 V9, Getting Started

allg_Hinweise.fm

LAN require-

ments

Does the LAN meet the requirements for Voice over IP? Has a

network analysis been performed? Are the results available? Isthere a list of IP addresses that are already assigned/still avail-able? Are the IP addresses of the IP clients already defined andhave they been assigned call numbers?

Refer to the re-

quirements specifi-cation

HiPath 3000 Ser-vice Manual, Chap-ter IP Fundamen-tals

Administration It is configured using the service tool HiPath 3000 Manager C/ETo configure the HG 1500 module, you need Internet ExplorerV5.5 or later and Java. HiPath 3000 Manager should be availableon the technician’s service laptop or should be installed on a sta-tionary PC (administration PC) at the customer site (in agreement

with the customer). Or, in a HiPath3000/5000 network, the Man-ager can be installed on the HiPath 5000 RSM server (adminis-tration PC) for central administration.You can install both of these programs from CD 1 via the mastersetup. Is there no CD?● If you are a customer: Ask your contact at Siemens.● If you are a Siemens technician: Load the programs from the

software server (SWS).The V.24 interface and then thae LAN are used to connect to thesystem.

Data protection

and data securi-ty

The data protection and data security notes as well as the secu-

rity checklist should be observed when starting up and servicingthe system.

HiPath 3000 ser-vice manual, dataprotection and datasecurity

Link to the securitychecklist:http://wiki.siemens-enterprise.com/ index.php/ Security_Checklist

 Subject Description Detailed infor-mation

Page 13: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 13/28

IP_Network.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 3-1 

Nur für den internen Gebrauch HiPath 3000/5000 V9 IP Systems

Step by Step Startup 

3 HiPath 3000/5000 V9 IP Systems

3.1 Step by Step Startup

Perform the steps described below in chronological order to start up multiple HiPath 3000 sys-tems with HG 1500 modules or with the HiPath 5000 server. Each subject has a cross referenceto relevant documentation providing further details. If you have these instructions in electronicform, click the blue links and you will be branched to the corresponding documentation.

3.2 Installing the Hardware

>Startup of a single HiPath 3000 system is described below. When starting additionalHiPath 3000 systems perform the steps described below again.

Activity/description Detailedinformation

1. Mounting/installing the HiPath 3000 system. HiPath 3000 Ser-vice Manual,Chapter HiPath3000 Installation

2. Mounting and installing the client PCs, administration PC and - if nec-essary - switches and routers.

3. Mounting, installing, and cabling of workpoint clients on a system-spe-cific basis.

HiPath 3000 Ser-vice Manual,Chapter WorkpointClients

Status:The HiPath 3000 system/the HiPath 3000 systems and the workpointclients in use are located at their installation sites and are physicallyconnected to the LAN.

Page 14: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 14/28

HiPath 3000/5000 V9 IP Systems Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

3-2 HiPath 3000/5000 V9, Getting Started

IP_Network.fm

Installing Additional HiPath 3000 Modules 

3.3 Installing Additional HiPath 3000 Modules

Activity/description Detailed

information1. The system must be disconnected from the power source (in the case

of HiPath 35x0 and HiPath 33x0) before new modules are added.HiPath 3000 Ser-vice Manual,Chapter HiPath3000 Modules

2. Check the available ports (master/slave) for each slot (HDLC). HiPath 3000 Ser-vice Manual,Chapter Configu-ration Instructions

Status:New modules are installed correctly in the system.

Page 15: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 15/28

IP_Network.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 3-3 

Nur für den internen Gebrauch HiPath 3000/5000 V9 IP Systems

Initial Startup of HiPath 3000 

3.4 Initial Startup of HiPath 3000

Initial startup must be performed for each HiPath 3000 system.

7 Caution (for Brazil only)

For protection against overvoltage due to lightning, the use of the lightning protectionstrip with part number C39334-Z7052-C31 is absolutely mandatory. In the HiPath3000 Service Manual, HiPath 3000 Startup Chapter, following the described voltagesupply steps.

Activity/description Detailedinformation

1. Connect the V.24 interface of the HG 1500 module and the serial inter-face of the administration PC (e.g. COM1) using a null modem cable.Note:Initial connection of the system to the LAN using a direct connection(null modem cable) is described below.

HiPath 3000 Ser-vice Manual,Boards Chapter,select the corre-sponding board(e.g. HXGM3,

HXGR3, HXGS3,

etc.).

2. Connect the system to the power source and perform a reload. A de-fault CDB (Customer DataBase) is loaded with the country setting“Germany”.Note:When using a lightning protection strip (part number C39334-Z7052-C31), carry out the voltage supply steps described in the Service Man-ual.

HiPath 3000 Ser-vice Manual,Chapter HiPath3000 Startup

3. Perform country initialization with Assistant T, if necessary. “Germany”is set by default. If you have changed the country initialization, theHiPath 3000 is restarted.

HiPath 3000 Ser-vice Manual,Chapter HiPath3000 Startup

Status:The HiPath 3000 is booted, the connected system telephones are de-tected and the ISDN lines are configured for the EDSS1 protocol.

Page 16: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 16/28

HiPath 3000/5000 V9 IP Systems Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

3-4 HiPath 3000/5000 V9, Getting Started

IP_Network.fm

Connecting the HiPath 3000 to the LAN via the HG 1500 

3.5 Connecting the HiPath 3000 to the LAN via the HG 1500

The HiPath 3000 is connected to the LAN via the HG 1500. You must first assign an IP addressto the LAN1 interface of the HG 1500 and a default router to the gateway. When connecting

additional HiPath 3000 systems (nodes) you must repeat the steps described below.

For initial setup of the HG 1500, you have the following possibilities:

● use the Command Line Interpreter (CLI)

● carry out the initial setup via remote access

Initial setup using the CLI is described below.

Activity/description Detailedinformation

Starting and configuring the HyperTerminal connection

1. Start HyperTerminal on the administration PC underStart | Programs | Accessories | Communications.

Make the following settings:

2. Specify a name for the connection, e.g. HG 1500.

3. Select the COM port to which the HG 1500 is connected, e.g. COM1.

4. Make these settings:● for HG 1500 – 19200 bps● for STMI – 38400 bps

Administration using the Command Line Interface (CLI)

1. When the HyperTerminal connection has been established, you canaccess the HG 1500by pressing the Enter key.

HG 1500 Admin.,Chap. Configura-tion via CLI Inter-face

2. Log on with a username and password. The default username andpassword can be obtained from the system administrator.

Note:You can change the username and password using HiPath 3000Manager E in the HiPath 3000 system.

In the CLI, enter the following commands after the vxTarget> prompt:

3. get write access Activates write function.

Page 17: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 17/28

IP_Network.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 3-5 

Nur für den internen Gebrauch HiPath 3000/5000 V9 IP Systems

Connecting the HiPath 3000 to the LAN via the HG 1500 

4. set ip address xxx.xxx.xxx.xxx 

Wildcard for IP address of the HG 1500 LAN1 interface, e.g.1.150.1.232Note:Before assigning an IP address, use Ping to ensure that this addresshas not already been assigned.

5. set ip subnet yyy.yyy.yyy.yyy Wildcard for subnet mask of the HG 1500 LAN1 interface, e.g.255.0.0.0

6. set default gateway zzz.zzz.zzz.zzz Wildcard for the default router of the gateway, e.g. 1.150.6.10

7. add wbm client aaa.aaa.aaa.aaa Wildcard for PC that the HG 1500 can configure using Web-BasedManagement, e.g. 1.150.1.10.

8. save configuration Stores the settings.

9. reset Restarts the HG 1500.

Once the entries for IP addresses 1 and 2 are displayed on the CLI, thereset is complete. Press the Enter key again to return to the login

prompt.

Closing the HyperTerminal connection

1. Close the “HyperTerminal” program to release the COM interface forsubsequent administration with HiPath 3000 Manager.

Administration with HiPath 3000 Manager

1. Connect the V.24 interface of the HiPath 3000 and the serial interfaceof the administration PC using a null modem cable.

Note:You can remove the null modem cable from the HG 1500 and insert itin the HiPath 3000 V.24 interface. This can be done while the systemis running.

HiPath 3000 Ser-vice Manual,

Chapter HiPath3000 Modules

Activity/description Detailedinformation

Page 18: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 18/28

HiPath 3000/5000 V9 IP Systems Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

3-6 HiPath 3000/5000 V9, Getting Started

IP_Network.fm

Connecting the HiPath 3000 to the LAN via the HG 1500 

2. Start HiPath 3000 Manager with Start | Programs | HiPath 3000 Man-

ager | HiPath 3000 Manager and log on with a username and pass-word. The default username and password can be obtained from thesystem administrator.Note:You can change the username and password using HiPath 3000Manager E in the HiPath 3000 system.

HiPath 3000 Man-

ager, Chapter Star-tup And Login

3. Load the CDB from the HiPath 3000 by means of the direct connectionwith File | Transfer | Communication | System -> PC.The options Direct and Read/write CDB must be selected.

HiPath 3000 Man-ager, ChapterTransfer | Commu-nication

4. In Settings | Network | Basic Settings, set the IP access protocol toHIP.HiPath 3000 Man-ager, Chapter Ba-sic Settings

5. In Settings | Network | Basic Settings, enter the IP address of HiPath3000 (e.g. 1.150.1.231) and the subnet mask of HiPath 3000(255.0.0.0) in the LAN Interface field.

HiPath 3000 Man-ager, Chapter Ba-sic Settings

6. If required you can define which IP PC can be reached via which gate-way under Settings | Network... | Routing . To do this enter the IPPCs IP address (e.g. 1.150.1.112), the subnet mask (network maske.g. 255.0.0.0) and the gateway (e.g. 1.150.1.10).

HiPath 3000 Man-ager, ChapterRouting

7. Restore the data to the system via the direct connection with File |Transfer | Communication | PC -> System.

HiPath 3000 Man-ager, ChapterTransfer | Commu-nication

8. Save the CDB.File | Save CDB As...

HiPath 3000 Man-ager, ChapterSave CDB As...

Status:The HiPath 3000 can now be configured via LAN with HiPath 3000Manager. The null modem cable can be removed from the HiPath3000.

Activity/description Detailedinformation

Page 19: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 19/28

IP_Network.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 3-7 

Nur für den internen Gebrauch HiPath 3000/5000 V9 IP Systems

Initial Configuration of the HiPath 3000 

3.6 Initial Configuration of the HiPath 3000

Initial configuration must be performed for each individual HiPath 3000 system.

Activity/description Detailedinformation

1. Connect the HG 1500 of the HiPath 3000 with the LAN.Note:The administration PC must also be connected to the LAN.

HiPath 3000 Ser-vice Manual,Boards Chapter,select the corre-sponding board

(e.g. HXGM3,

HXGR3, HXGS3,

etc.).

2. Check the LAN connection to the HG 1500 and to the HiPath 3000 us-ing a Ping command (e.g. ping 1.150.1.231).Now use HiPath 3000 Manager to load the CDB of HiPath 3000 withFile | Transfer | Communication | System -> PC.The options Read/write CDB and IP HiPath must be selected. As theIP address, select the IP address of the HiPath 3000 (in our example:1.150.1.231).

HiPath 3000 Man-ager, ChapterTransfer | Commu-nication

3. Check whether the system telephones were detected correctly by se-lecting Settings | Set up Station | Stations.Assign the appropriate station names to the station numbers of the sys-

tem telephones (can be found in the customer’s numbering plan or therequirements specification).Note:Here you can already assign the appropriate station names to the sta-tion numbers of the IP clients (can be found in the customer’s number-ing plan or the requirements specification).

HiPath 3000 Man-ager, Chapter Setup Station | Sta-tions

4. You can change the station parameters by clicking the Station View button above the navigation area.

HiPath 3000 Man-ager, Chapter Sta-tion View

5. Enter a name for the system in the System Name field under Settings| System Parameters | System Settings. This name is displayed onthe display of the system telephones (currently not on OpenStage 40,60, 80).

HiPath 3000 Man-ager, Chapter Sys-tem Settings

6. Under Settings | Lines/Networking | Routes, specify a route name(e.g. ISDN) in the Route Name field and the international dialing code(e.g. 49), the area code (e.g. 89), and the call number of the systemwithout intercept code (e.g. 722) in the System Number-Incoming field.

HiPath 3000 Man-ager, Chap.Routes.

Page 20: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 20/28

HiPath 3000/5000 V9 IP Systems Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

3-8 HiPath 3000/5000 V9, Getting Started

IP_Network.fm

Initial Configuration of the HiPath 3000 

7. Check the protocol of the trunks with Settings | Lines/Networking |

Trunks. To do this, select a line and click the corresponding "Param"field.

HiPath 3000 Man-

ager, ChapterTrunks

8. Load any additional system languages with System Status | System-wide | System Texts. There are a total of eight system languages inall, four of which are defined by default and the other four loaded on auser-defined basis.Note:When loading the system languages, you should first transfer the CDBto the system, save it, and then change the system languages. A re-start is performed automatically following a change to the system lan-

guages.

HiPath 3000/5000Feature Usage Ex-amples, Swap-ping/ReplacingLanguages

9. Restore the data to the system withFile | Transfer | Communication | PC -> System

HiPath 3000 Man-ager, ChapterTransfer | Commu-nication

10. Save the CDB.File | Save CDB As...

HiPath 3000 Man-ager, ChapterSave CDB As...

The date and time are updated after the first connection setup to theCO.

Status:The system telephones have been set up correctly, the system is ac-cessible from the CO, and administration of the system via LAN is pos-sible.

Activity/description Detailedinformation

Page 21: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 21/28

IP_Network.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 3-9 

Nur für den internen Gebrauch HiPath 3000/5000 V9 IP Systems

Licensing the Features 

3.7 Licensing the Features

Some features must be licensed before you can use them. For example, these include the useof more than two B channels.

In this case you must install License Management, including a license agent (CLA), on a PC inthe network. The License Management software is available either on the software CD forHiPath 3000/5000 V9 or on a separate CD. After installation you can use License Managementto request a license file with the aid of the authorization code or MAC address of the HiPath3000 Control Board (CB). Details can be found in the License Management Online Help. Assoon as licensing is finished, you receive a license file, which is installed automatically in a sub-directory of the CLA (Customer License Agent). The licensing procedure must be repeated foreach HiPath 3000 system in the network. These files contain all of the data required for the sub-sequent distribution of the licenses for the features. This distribution of licenses is performedusing HiPath 3000 Manager.

>If the CLA and HiPath 3000 Manager are not on the same PC, the IP address of thePC on which the CLA is installed can be entered in a configuration file in theHiPath 3000 Manager directory.The configuration file (ass_150e.ini - Cla_Host) can be found in the directoryC:\Documents and Settings\Username\Application Data\Siemens\Manager E.

Activity/description Detailedinformation

Licensing the features with HiPath 3000 ManagerPerform the following steps for each HiPath 3000 system.

Requirement:You have installed License Management, including a license agent, on aPC in the network and have requested and received the required licensefile(s) (xml file). You can check that the license file(s) for the licenseagent has/have been transferred correctly with License Management.

HiPath 3000 Ser-vice Manual, Li-censing Chapter

1. Using HiPath 3000 Manager, load the CDB from the desired HiPath3000 path via File | Transfer | Communication | System -> PC.The options Read/write CDB and IP HiPath must be selected. As theIP address, select the IP address of the HiPath 3000 (in our example:1.150.1.231).

HiPath 3000 Man-ager, ChapterTransfer | Commu-

nication

2. Under Settings | Licensing, select the HXG tab. The license agent(CLA) opens the license file that corresponds to the MAC ID (of the Hi-Path 3000 system).

HiPath 3000 Man-ager, Chapter Li-censing

Page 22: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 22/28

HiPath 3000/5000 V9 IP Systems Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

3-10 HiPath 3000/5000 V9, Getting Started

IP_Network.fm

Licensing the Features 

3. Check and/or change the number of licensed B channels (default: 2 B

channels) and the number of licensed system clients (default: 0 systemclients).Note:In the case of multiple HiPath 3000 systems, decide how you want todistribute the licenses to the individual systems.

HiPath 3000 Man-

ager, Chapter Li-censing

4. Restore the data to the system withFile | Transfer | Communication | PC -> System

HiPath 3000 Man-ager, ChapterTransfer | Commu-nication

HiPath 3000 Man-

ager, ChapterTransfer | HiPath5000 Server

5. Save the CDB.File | Save CDB As...

HiPath 3000 Man-ager, ChapterSave CDB As....

Status:The features are licensed and the current CDB is loaded in the system.

Activity/description Detailedinformation

Page 23: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 23/28

IP_Network.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 3-11 

Nur für den internen Gebrauch HiPath 3000/5000 V9 IP Systems

Configuring the IP Clients 

3.8 Configuring the IP Clients

IP clients are both system clients such as the IP telephones OpenStage CorNet-IP (HFA) or IPclient software OpenScape UC Application or S0 /vCAPI stations such as H.323 clients or vCA-

PI clients. The IP clients must be configured in the HiPath 3000 and then managed in the clientsoftware.

Activity/description Detailedinformation

Configuration with HiPath 3000 Manager

1. Using HiPath 3000 Manager, load the CDB for the HiPath 3000 withFile | Transfer | Communication | System -> PC.

The options Read/write CDB and IP HiPath must be selected. As theIP address, select the IP address of the HiPath 3000 (in our example:1.150.1.231).

HiPath 3000 Man-ager, Chapter

Transfer | Commu-nication

2. In the Station View, select the station (IP client).

3. Click the arrow symbol after the station number entry to change to theSet up Station | Stations dialog.

4. For each station, enter the station number, the extension (DID number)and the name. To save the changes, click Apply.

5. In the menu Settings | Set up Station, change to Gatekeeper:●

In the Gatekeeper tab, select the slot for the HG 1500 module.● Select the IP station from the Stations list.● Specify whether the selected station is to be set up as a system cli-

ent, an H.323 client or an SIP client. Then click Set up. To save thechanges, click Apply.

Note 1:If you have already assigned names to the call numbers of the IP cli-ents (see 2.2.5), these names are displayed here.Note 2:If S0 stations are also to be configured on the Gatekeeper, the optionEnable Gateway Resources must be activated. Only then can the

Gateway tab be used to set up the S0 stations.

HiPath 3000 Man-

ager, ChapterGatekeeper

6. On the Gatekeeper tab, select the "System Client" for IP system tele-phones (e.g. optiPoint 420) and optiClient 130.

7. In the Gatekeeper tab, select the “H.323 Client” for H.323 clients andvCAPI stations.

Page 24: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 24/28

HiPath 3000/5000 V9 IP Systems Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

3-12 HiPath 3000/5000 V9, Getting Started

IP_Network.fm

Configuring the IP Clients 

8. In the Gatekeeper tab, select the “SIP Client” for SIP stations.

Note:SIP stations do not require a fixed IP address.

9. In addition, when configuring H.323 clients:In Station View, select the relevant H.323 client and click the Work-point Client tab. In the "IP address" field, select the option Fixed IPaddress and specify the IP address of the H.323 client.If an H.323 client is operated on the Gatekeeper, the Gatekeeper as-signs the call number and IP address. The IP address 0.0.0.0 must beconfigured in this case.Notes:

● Before assigning an IP address, use Ping to ensure that this ad-dress has not already been assigned.● If the parameter Analog adapter connected is activated, H.323

calls are carried out over a DSP and features are activated in thesystem.

HiPath 3000 Man-ager, Chapter Sta-tion View | Work-point Clients

10. Restore the data to the system withFile | Transfer | Communication | PC -> System

HiPath 3000 Man-ager, ChapterTransfer | Commu-nication

11. Save the CDB.File | Save CDB As...

HiPath 3000 Man-ager, ChapterSave CDB As...

Status:The IP clients are configured in the HiPath 3000 and can be managedusing the software.

Activity/description Detailedinformation

Page 25: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 25/28

IP_Network.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started 3-13 

Nur für den internen Gebrauch HiPath 3000/5000 V9 IP Systems

Configuring the IP Clients 

Administering an IP phone: OpenStage CorNet-IP (HFA) on HiPath3000 V9 (for example, an OpenStage 40/60/80)

For an IP phone to be able to register on HiPath 3000, the HiPath 3000phone number and IP address must be entered on the IP phone.Requirement: The IP phone must be connected to HiPath 3000 andready to use.

1. Call up administration mode on the IP phone:

1. On the phone, press the key to access the Settings/Applica-tions menu.

2. On the Settings tab, scroll to Admin and press OK.

3. Enter the administration password (default: 123456) and con-firm by pressing OK.

2. Scroll to Network and confirm by pressing OK.

3. If you use a DHCP server in your internal network, skip the next step.

4. If you do not use a DHCP server in your internal network, you must en-ter the IP address of the Deployment Server (DLS), so the IP phonesoftware can be automatically updated:

1. Scroll to Update service (DLS) and confirm by pressing OK.

2. Scroll to DLS address and confirm by pressing OK.

3. As the Deployment Server, enter the IP address ofHiPath 3000 and confirm by pressing OK.

4. Scroll to Save & Exit and confirm by pressing OK.

5. Scroll to IP configuration and confirm by pressing OK.

6. Scroll to Route (default) and confirm by pressing OK.

7. Enter the IP address of HiPath 3000 and confirm by pressing OK.

8. Scroll to Save & Exit and confirm by pressing OK.

9. Return to the previous level in the menu by pressing Back.

10. Scroll to System and confirm by pressing OK.

11. Scroll to Identity and confirm by pressing OK.

12. Scroll to Terminal number and confirm by pressing OK.

13. Enter the set phone number and confirm by pressing OK.

Activity/description Detailedinformation

Page 26: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 26/28

HiPath 3000/5000 V9 IP Systems Nur für den internen Gebrauch

 A31003-H3590-G100-4-7631, 10/2011

3-14 HiPath 3000/5000 V9, Getting Started

IP_Network.fm

Further Configuration 

3.9 Further Configuration

Additional settings such as least cost routing (LCR), call pickup groups, or class of servicesmust be configured with HiPath 3000 Manager. These settings should only be made by trainedservice personnel.

3.10 Connection to the InternetYou can establish an Internet connection using the HG 1500 board integrated in theHiPath 3000. Information on the different options available and instructions for configuring themare provided with examples in the document "HiPath 3000/5000 Feature Usage Examples,Chapter Practical Examples HG 1500".

14. Scroll to Save & Exit and confirm by pressing OK.

15. Return to the previous level in the menu by pressing Back.

16. If the IP phone needs to be restarted because changes have beenmade, the Admin menu features the menu item Restart.

17. Confirm Restart by pressing OK and then confirm Yes by pressing OK.The IP phone restarts and registers on HiPath 3000.

Administration of an IP software client (H.323 client)

1. When configuring the IP client, specify the IP address of theHG 1500 as a gatekeeper!

Status:The IP clients are ready.

Activity/description Detailedinformation

Page 27: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 27/28

GetstartedSIX.fm

A31003-H3590-G100-4-7631, 10/2011

HiPath 3000/5000 V9, Getting Started Z-1

Nur für den internen Gebrauch Index

Index Z

AAdministration 2-2

BBackup Manager 1-6

FFeature Description 1-5

H

HG 1500 1-5HiPath 3000 IP Systemdelivery documents 2-1licensing 2-1numbering plan 2-1requirements specification 2-1safety notes 2-1

HiPath 3000 networked IP systemsassigning IP addresses 3-4configuring IP functionality 3-11hardware installation 3-1

IInstallation and startup 2-1Internet connection 3-14Introduction 1-1Inventory Manager 1-6

LLAN 2-2License Management 3-9Licensing 3-9

MManager E 1-5

SService Manual 1-5Software Manager 1-6Startup 3-1Symbols 1-4

TTypographical conventions 1-4

U

Upgrade Manager 1-6

VVarieties of HiPath 3000/5000

IP System (Standalone) 1-1Networked IP Systems 1-1

Page 28: HiPath 3000 5000 V9 Getting Started Issue 4

8/20/2019 HiPath 3000 5000 V9 Getting Started Issue 4

http://slidepdf.com/reader/full/hipath-3000-5000-v9-getting-started-issue-4 28/28

Index Nur für den internen Gebrauch

GetstartedSIX.fm