history 1992 - 2009
TRANSCRIPT
Cryoelectra
GmbH ELBE Workshop in Dresden-Rossendorf 14. März 2013
History
and Products 1963 -
1992 -
2009
Cryoelectra
GmbH ELBE Workshop in Dresden-Rossendorf 14. März 2013
Early University Work
1966
(Bonn University) Work in digital controlled electronics for particle detectors with the first generation of ICs and design of the magnet ring of the 2.3GeV Synchrotron
1972
(Bonn University): Start of the work in RF superconductivity for particle accelerators and development pf the first LLRF control electronics
1976 to 1979
Design of the Darmstadt Superconducting Linac (S-DALINAC) together with A. Richter
1978
Discovery that cavities of “spherical shape are free of multipacting (together with D.Proch and U.Klein) based on work at Stanford and Genova
1979 Development of temperature mapping of sc. cavities at high fields
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Cryoelectra History 1988: Start of the development of a superconducting UMTS pre-
selection filter with steep skirts for NTT-DoCoMo (1920-1940 MHz). Later on in collaboration with Ericsson
1.88 1.89 1.90 1.91 1.92 1.93 1.94 1.95 1.96 1.97 1.98-100
-80
-60
-40
-20
0
f [GHz]
|S21
| [dB
]
-50
-40
-30
-20
-10
0
|S11| [dB]
Cryoelectra
GmbH ELBE Workshop in Dresden-Rossendorf 14. März 2013
•
Location
Wuppertal, Germany•
Registry
HRB 7858 •
Foundation 1992•
1. Geschäftsführer :
Prof. Dr. Helmut Piel •
2. Geschäftsführer
Dr. Nico Pupeter
Gesellschafter
(partners)•
Prof. Dr. Aleks Braginski
(Jülich)
Prof. Dr. K. Held•
Alice Ann Wright, Los Alamos
Prof. Dr. H. Piel (a.p.)•
Prof. Dr. J. Drees (Wuppertal) (a.p.)
Dr. N. Pupeter (a.p.)•
Prof. Dr. r. Eujen (Wuppertal)
Prof. Dr. B. Mönter (Salzburg)•
Prof. Dr. A. Gladun (Dresden)
Prof. Dr. W. Weber (Dortmund)•
Prof. Dr. Stuart Wolf (Washington))
Varian Medical Systems PT17 Employees, incl. 7 PhD. Physicists and Engineers, 5 administrative and technical staff members and 5 helping hands (mini jobs) –
a.p. = acting partnerStammkapital 140.000 €
Company Profile
A Commercial RF Pre-Amplifier for an HTS RF Front End
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Field Test in Beijing
Cryoelectra HTS Pre selection filters and cryogenic Pre amplifiers are installed in 5 Base Stations in down town Beijing and are successful in operation since 2006
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Unser erster Verstärker
1999-2000
Development of our first “balanced amplifier”
as low noise
preamplifier (1mW) and as a high power transmission amplifier (100W) for the front end of mobile communication base stations. Successful field tests in Beijing in 2004-2009
2002 return to accelerator electronics and cooperation with the COSY group at FZ Jülich.
2003
Establishment of a strategic partnership with ACCEL and start of high power amplifier and LLRF work
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
The Balanced Amplifier Design
Excellent external matching
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Cryoelectra
GmbH ELBE Workshop in Dresden-Rossendorf 14. März 2013
Design Layout of the SARAF accelerator (p/d 40 MeV)
•Study of magnetic coupler
• Accelerator beam line layout with TRACE, TRACK, PARMELA and TURTLE
•Layout of Half-Wave-resonators •Multipacting anaysis
Cryoelectra Solid State Amplifiers
•
Range of frequencies: 72MHz to 3GHz, •
Output power 150 kW cw., pulse or cw. –
operation,
•
Industrial Design –
convenient operation and maintenance (19“
Chassis-
or cabinet-design)
•
Use of balanced amplifiers as basic building blocks wherever possible
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Our first 1.3GHz Amplifiers, delivered 2006 to DESYTotal RF power: 5.2kW using 125W transistors
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Cross section of 4 balanced 1.3GHz SS Amplifiers mounted on a
WR650 Wave Guide
TransistorZirkulator
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Two pairs of balanced 500W amplifiers mounted on a WR650 waveguide
Compact Design 18kW 1.3GHz SSA
• 0,99 Power Conversion Factor• >94% AC/DC conversion efficiency• Air cooling• Redundant parallel combination • Control via Ethernet • 16(+2 kW) per 3 HU
APR48-ES(Energy Saver)In: 120-230VAC Out: 43-50VDC 16 kW (+2) per 3HU
A compact technical Concept of a 18kW 1.3 GHz SSA
apr48
EATON
ESENERGY SAVER
apr48
EATON
ESENERGY SA VER
apr48
EATON
ESENERG Y SA VER
apr48
EATON
ESENERG Y SAVER
apr48
EATON
ESENERG Y SAVER
apr48
EATON
ESENERGY SAVER
apr48
EATON
ESENERGY SA VER
apr48
EATON
ESENERG Y SA VER
apr48
EATON
ESENERG Y SA VER
UD: 50 VDCT=45°CAlarm: noSet-Op: ON
ESENERGY SA VER
apr48
EATON
apr48
EATON
ESENERGY SAVER
apr48
EATON
ESENERGY SA VER
apr48
EATON
ESENERG Y SA VER
apr48
EATON
ESENERG Y SAVER
apr48
EATON
ESENERG Y SAVER
apr48
EATON
ESENERGY SAVER
apr48
EATON
ESENERGY SA VER
apr48
EATON
ESENERG Y SA VER
apr48
EATON
ESENERG Y SA VER
UD: 50 VDCT=45°CAlarm: noSet-Op: ON
ESENERGY SA VER
apr48
EATON
AC Mains Distribution
Cryoelectra
RF Module Controller CRE-341A-6.21A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
7A
7B
8A
8B
9A
9B
10A
10B
11A
11B
D1A
D1B
CryoelectraRF Module Controller
CRE-333A-6.2
ACDC Converter9x 2 kW 230VAC in / 50VDC out
ACDC Converter9x 2 kW 230VAC in / 50VDC out
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Cryoelectra
UHF Solid State Amplifier
CRE-333A
1.300 MHz 18 kW AB, cw
Water cooled
High efficiency
Diagnostic for each module:
Pfor
, Pref
, Itrans
, Temp
Size [mm³]: 1000x1000x 2400
Output: WR650
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Solid State HPA 500 MHz 70kW
for Helmholtzzentrum Berlin BESSY II Project
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Waveguide coupled output 18 kW
Water cooler
Waveguide WR650 1.3 GHz, 2x 9 kW
RF Module 500 W
40 RF Inputs
Water supply
ACDC Conversion230VAC –
50VDC 2x 9x 2kW
4 Modules front, 4 rear = 4kW per row
Mains input, switch and fusing
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Losses and efficiencies High Efficiency Layout
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Two balanced 500W Amplifier Modules mounted on a WR650 waveguide
The Demonstrator D6 used in the Wunongchang Field Test (2004)
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Arrangement of the HTS Filter-LNA-Combination
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Highest Efficiency AC/DC-Conversion
ControllerAPR48-ES
APR48-ES(Energy Saver)In: 120-230VAC Out: 43-50VDC 16 kW (+2) per 3HU
Converter50V /2kW
9 in parallel1 redundant
• 0,99 Power Conversion Factor•
>94% AC/DC conversion
efficiency• Air cooling• Redundant parallel combination • Control via Ethernet • 16(+2 kW) per 3 HU
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013
Cryoelectra Halbleiterverstärker Besonderheiten
•Überwachung der Funktionsdaten jedes einzelnen Transistors•Automatische Konditionierung von Beschleunigungsresonatoren in Kombination mit der Cryoelectra HF-Kontrollelektronik (digital LLRF)
Cryoelectra
GmbH Treffen bei BESSY 2. Februar 2012
The Balanced Amplifier Design
Excellent external matching
Cryoelectra
GmbH Elbe Workshop in Dresden-Rossendorf 14.März 2013