hkz ozonator canopy 1 2 3 4 5 6 7 8 - ets nord · images are for illustrative purposes 7 ... always...
TRANSCRIPT
1
2
3
4
5
6
7
8
9
10
11
5Images are for illustrative purposesWe reserve the right to make changes
®
NO
RD
cano
py
| H
KZ
HKZ ozonator canopy is a combination of effective grease removal and stylish design. The canopy is equip-ped with an integrated ozonator and a smart control system, that guarantee efficient and reliable cleaning for kitchen exhaust air. The canopy extracts impurities and excess heat from the kitchen, while removing grease from exhaust air with ozone treatment. Ozone treatment ensures that grease and odor problems in the exhaust duct are substantially decreased, resulting in a smaller fire risk and happy neighbors.
Ozonator canopy advantages
Effective two-phase cleaning Phase 1: Mechanical grease separationPhase 2: Exhaust air ozone treatment
Notably increased fire safety
Up to 95% decreased odors
Enables heat recovery
Low operating cost
No consumable parts
Maintenance service
Canopy construction complies with the standard EN 16282-2 Equipment for commercial kitchens – Kitchen ventilation hoods; design and safety requirements.Ozonator technology used in the canopy complies with standard EN 16282-8 Equipment for commercial kit-chens – Installations for treatment of aerosol. Requirements and testing.
HKZ Ozonator canopy
4
5
6
7
8
9
10
11
www.etsnord.com6
®N
OR
Dca
nopy
|
HK
Z
Reccomended data
Lenght L
Extraction air flow l/s,
(∆ptot 14-48 Pa)
Supply air flowper linear meter of front panel, l/s per linear
meter of side panel, l/s Turbo Grip, l/sSPx1 SPx2 SPx3
1500 210-390
10-40 Pa 68-130 l/s
10-37 Pa 108-190 l/s
10-25 Pa 160-250 l/s
10-40 Pa 22-40 l/s
10-40 Pa 7-15 l/s
2000 280-5202500 350-6502900 420-780
FunctionHot and greasy air is sucked through the filters into the exhaust air chamber. The mechanical grease filters collect most of the large grease particles, which drip down from the filters to the grease collection container. Ozone sucked into the exhaust air chamber mixes up with greasy air, continuing to clean it in the exhaust air duct.Turbo Grip air curtain directs the greasy air rising up from the kitchen appliances into the hood and towards the grease filters.Supply air module delivers clean air to replace the extracted greasy air. Supply air is delivered through holes in the front plate and the adjustable extra air holes on the bottom side of the supply air module.Ozonator is located inside the supply air chamber, out of which it sucks the clean air for the production of ozone. The underpressure of the exhaust air sucks the ozonated air into the exhaust air chamber, where ozone starts to break the grease particles.
Construction and dimensionsThe canopy is made of 1 mm thick stainless steel (AISI 304, surface 2K). Duct connections are equipped with a rubber gasket and the supply air chamber is heat insulated to prevent the condensation of steam on to the inner surface of the canopy. For fixing the canopy there are hanging screws in each corner of the canopy roof.All NORDcanopy kitchen canopies are manufactured as custom orders. There can be several modules and they can be shaped completely according to project requirements and special demand.
54 6 8
1111 1212 141313 1610
1 77
15
92 3
A A
B B
C C
D D
E E
F F
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DRAWN
CHK'D
APPV'D
MFG
Q.A
UNLESS OTHERWISE SPECIFIED:DIMENSIONS ARE IN MILLIMETERSSURFACE FINISH:TOLERANCES: LINEAR: ANGULAR:
FINISH: DEBURR AND BREAK SHARP EDGES
NAME SIGNATURE DATE
MATERIAL:
DO NOT SCALE DRAWING REVISION
TITLE:
DWG NO.
SCALE:1:20 SHEET 1 OF 4
A3
WEIGHT:
G4.00.00
1- Front panel2- Ozonator3- Regulating damper4- Supply air connection5- Supply air adjusting plate6- Lighting7- Suspension points8- Exhaust air connection9- Adjusting plate for exhaust air10- Front panel lock11- Auxiliary supply openings12- Turbo Grip air intake13- Air flow measuring nozzles14- HFK grease filter15- Blind panel for grease filter16- Grease collection container
1
2
3
4
5
6
7
8
9
10
11
7Images are for illustrative purposesWe reserve the right to make changes
®
NO
RD
cano
py
| H
KZ
LightingProfessional kitchen requires functioning lighting, which guarantees the employees good working conditions. ETS NORD professional kitchen canopies use next generation energy efficient LED lights, which can save up to 50% more energy compared to older fluorescent lights.Grease removal canopies use a light integrated into the ceiling of the canopy covered by a casing made of aluminum and glass. Condensation canopies use surface mounted lighting covered in glass fiber reinforced plastic casing, which is attached to the support frame of the condensation plates. Casing protection class is IP66.The size and number of lights is determined based on the size of the canopy, so that there is enough light output for the working space.Luminaries:
Canopy length (mm) Marking
Lighting length (mm)
Energy cons. (W) Light color
Color temperature
(K)
Color rendering index (Ra)
Flux (lm)
1000 ≤ L <1550 LED770 769 20 840 4000 80 2250L ≥1550 LED1370 1369 37 840 4000 80 4900L <1550 LED1670 1669 53 840 4000 80 6750
Dimensions
HKZ Dimensions, mm
L Lenght 800, 900, ..., 2800, 2900B Width 900, 1000, ..., 1700, 1800H Height 400, 550
HKZ-1 Wall installation, 1-part HKZ-1 Island installation, 1-part (with HFKV modul)
L Lenght 800,900, ..., 2800, 2900 L Lenght 800,900, ..., 2800, 2900B Width
B=900 (No lighting)B=1000,1100, ..., 1800
B Width B=1500 (No lighting)B=1600, 1700 (1 row of lights)B=1800, ..., 2900 (2 row of lights)
H Height 400, 550 H Height 400, 550S1 160, 200, 250 S2 160, 200, 250E1 200, 250, 315 E3 200, 250, 315, 400 (HFKV moodul)
H+1
50
E3
S2
SPxK
SPxK
B
L
180
Product
SPx2SPx3
SPx0SPx1
HFKV
H
J. Junolainen 15.06.2018
Brushed AISI 304
SheetLeht
Drawn ByJoonestas
MaterialMaterjal
ProductToode
10/19
HKZ-LxBxH-S1-E1-SP-HFK-LED
SPx0SPx1SPx2SPx3
H
H+1
50
S1
E1
SPxK
SPxK
L
B
130
215 180
Service area Service area
4
5
6
7
8
9
10
11
www.etsnord.com8
®N
OR
Dca
nopy
|
HK
Z
HKZ-2 Island installation, 2-parts HKZ-2 Island installation, 2-partsL Lenght 800,900, ..., 2800, 2900 L Lenght 500, 600, ..., 2800, 2900B Width B=1800, 1900 (No lighting)
B=2000, 2200, ..., 3400, 3600B Width B=1800, 1900 (No lighting)
B=2000, 2200, ..., 3400, 3600
B1/B2 Width 900 (No lighting)1000,1100, ..., 1800 B1/B2 Width 900 (No lighting)
1000,1100, ..., 1800
H Height 400, 550 H Height 400, 550S1 160, 200, 250 S1 160, 200, 250E1 200, 250, 315 E1,E2 200, 250, 315
Hood lengthening with modular sections
H+1
50
SPx0SPx1SPx2SPx3
H
Connected chambers SPxK
SPxK 180
E2
S1
B
L
B1 B2 E
1
Service area
H+1
50
SPx3SPx2
SPx0SPx1
ConnectedChambers
H
Product
SPxK
SPxK B
E1 B2
L
S1
B1 215 180
Service area
J. Junolainen
15.06.2018
Brushed AISI 304
SheetLeht
Dra
wn By
Joonestas
Ma
terial
Ma
terjal
Product
Toode8/19
HKR-LxBxH
-S1-E1-SP-HFK-LED
B
S1
E1
215 180
L L1 L2 L3
Preferred lenght dimensions are 1000, 1500, 2000 mm
1
2
3
4
5
6
7
8
9
10
11
9Images are for illustrative purposesWe reserve the right to make changes
®
NO
RD
cano
py
| H
KZ
Technical data Supply air values per one meter of canopy length.
Facts about OzoneOzone is a colorless gas with a pungent smell that can often be detected by any person at a concentration of 0,02 ppm(0,4 mg/m3). The smell of ozone is similar to chlorine like in a swimming pool.Local protection legislations must be followed when using ozone. In Sweden, for example, the Swedish Work EnvironmentAuthority issues the following hygienic limits for ozone:
• 0,1 ppm (during a working day, 8 hours)• 0,3 ppm (during 15 minutes)
At acute exposure ozone can cause following injuries:• On skin: Irritation and burning feeling• In eyes: Hard irritation, burn injuries and reduced vision• In lungs: Irritated effect on respiratory organs and breathing problems
Always take corrective action and safety precautions if ozone is detected in an indoor environment.
HKR_SP_Turbo grip 1m.grf
Air flow qv (l/s)
Pre
ssur
e dr
op
p tot
(Pa)
7 8 9 10 20 303010
20
30
40
506070
100
200
30
40
LpA, dB(A)
20
HKR_SP_Front_panel.grf
Air flow qv (l/s)
Pre
ssur
e dr
op
p tot
(Pa)
40 50 60 70 80 90100 200 300 400 500 600567
10
20
30
40
506070
100 SPx1 SPx2 SPx3
LpA, dB(A)
30
40
20
50
Supply air: "Turbo grip", 1 m Supply air: front panel, 1m
HKR_Side_panel.grf
Air flow qv (l/s)
Pre
ssur
e dr
op
p tot
(Pa)
5 6 7 8 9 10 20 30 40 50 60 70701
2
3
45
7
10
20
30
4050
70
100
LpA, dB(A)
30
40
20
Supply air: side panel, 1m
hfk_filter_zenner_070618.grf
Air flow qv (l/s)
Pres
sure
dro
p p t
ot (P
a)
50 54 60 64 70 74 80 84 9094 100 110 120 130 140 150 170 20010
20
30
40
50
60708090100
LpA, dB(A)
40
30
50
HFK filter
4
5
6
7
8
9
10
11
www.etsnord.com10
®N
OR
Dca
nopy
|
HK
Z
Ozonator electrical connectionsOzonator installation must be performed by an authorized electrician and the installation must abide by national standards and regulations. The interlock displayed in the graph below is mandatory. Typical example of an interlock is to cut off power from the ozonator when the exhaust fan is turned off or loses power. An all-pole safety switch with a break length of at least 3 mm must be installed as well. The ozonator requires 230 V AC and 50 Hz. The alarm panel must be connected to it’s own 10 A slow fuse.
Performed by electrician Plug & Play
Interlocking Device
External Alarm Outlet
AirMaid® Alarm panel
All-pole Safety Switch
LNPE
Plug and play(ax 4 zonators)
Junction box(not included)
230 VACMAX 10A
Performed by electrician Plug & Play
Interlocking Device
230 VACMAX 10A
All-pole Safety Switch
LNPE
Plug and play
1
2
3
4
5
6
7
8
9
10
11
11Images are for illustrative purposesWe reserve the right to make changes
®
Product marking
Marking - Dimensions - Supply air - Exhaust air - Front panel - Grease filters - Lighting
HKZ - 1 modul in widthHKZ-2 -2 moduls in width
L - LenghtB - WidthH - Height
S1 - Supply air chamber on one sideS2 - Supply air chambers on two sidesDiameter of supply air connectionQuantity of supply air connections
E1 - One exhaust air chamberE2 - Two exhaust air chambersE3 - HFKV exhaust air moduleDiameter of exhaust air connectionQuantity of exhaust air connections
SPx0 - Only “Turbo Grip” air intake systemSPx1 - Perforation pattern 1SPx2 - Perforation pattern 2SPx3 - Perforation pattern 3SPxK - Perforation pattern on side panel
HFK Grease filters quantity
LED770 - L=769, 20WLED1370 - L=1369, 37WLED1670 - L=1669, 53WQuantity of lightings
Example: HKZ-2 3500x2400x550 - S1=250x8 - E1=315x4 - SPx3 - HFKx12 - LED1370x4
Blind plate: Instead of filter (low air volumes). Extra panel installed instead of filter. Blind filter will cover part of filter area to ensure suffi cient pressure loss and air velocity.